Application Manual
COBRA PARK MASTER R0390, R0290 and R0190
Rear Parking Aid Systems Installation & Configuration Guide
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
1
1. Installation tools
2mm drill
17mm drill
Drill/Hole Cutter size a) R0390 = 17mm b) R0290, R0190 = 20mm
20mm drill
17mm hole cutter
2. Kit content
R0394
Kit content:
R0294, R0194
1, Sensor 1, Sensor leads (Sensor 1 & 2) 2, Sensor leads (Sensors 3 & 4) B, Double sided sticky pad (ECU) B1, Double sided sticky pad (Buzzer) M, ECU A, Buzzer F, Tie-wraps C, Power and buzzer harness T1-T2-T3-T4, Sensors
F0390 only:
G, Double sided sticky pads (Sensors) E, Sensor mounting collars D, Bumper D, Bumper wipe
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
2
3. Sensor painting
Before spraying, check the original vehicle paint code. Spray the primer, ensure it is completely dry before painting the sensors the vehicle colour. Let the vehicle colour paint dry thoroughly and spray with a gloss coating to protect the paint as required. The maximum temperature of the oven should not exceed 70° C. See Section 22 for detailed sensor spraying information .
4. Sensor positioning R0390
R0290
200-540
300-640
200-540
R0190
If sensors are installed within the parameters outlined above it should not be necessary to perform the ECU parameter programming procedure. If sensors are outside these parameters refer to Section 5 for sensor measuring and Section 17 for the ECU parameter programming procedure. The sensors minimum installation height is 400 mm with a 0 degree angle. If sensors are installed higher than 550 mm the sensitivity should be increased to ensure obstacle detection, see Section 17. If the 22mm or 25mm sensors are installed higher than 550mm consider using angled spacers.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
3
5.0 Bumper marking, removal and drilling Mark the sensor locations on the bumper exactly in position and ensure that any lines drawn on the bumper are done so using a marker that can be wiped away without trace. trace . Take time to confirm all your measurements are correct and accurate.
Remove the bumper, disconnecting vehicle lights as applicable. Drill a 2 mm hole for each sensor.
5.1 Measuring sensor positions
If sensors are to be installed in a horizontal line, take the measurements as shown above.
If sensors are to be installed at different height positions, take the measurements as shown above. The vertical offset should not be greater than 100mm.
If the side sensors have different measurements use the largest measurement for both when programming, see Section 17.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
4
6. Patch adhesion promoter (R0390) Wear latex gloves handling the Patch Primer. Clean the mouting collars (see Section 7) then the bumper (see Section 8).
7. Mounting collar preparation (R0390) Clean the mounting sides of the mounting collars as shown above. Fix a double sided sticky pad to each mounting collar leaving the red backing in place.
8. Bumper preparation (R0390) Surface cleaning Clean the internal surface of the bumper applying the Patch Primer on areas slightly larger than the mounting collar size. IMPORTANT Extra care should should be taken when using the enclosed cleaning pad, to ensure that the fluid doesn’t come into contact with the paintwork of the vehicle, as damage will result.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
5
9. Recommended hole cutters The recommend hole cutter tools for 0390 series are; VPL3312 – 17mm punch tool VPL3239 – 17mm drill The recommend hole cutter tools for 0190 and 0290 series are; VPL3299 – 20mm drill NOTE: Punch tools provide a better finish by forming the hole edge inwards and a clean cut to the paint work, removing the need to paint the hole edges of the bumper.
10. Sensor cleaning, preparation and adjustment (R0390) Sensor setup a) Remove any excess paint from the rubber surround of the sensors. b) Screw the sensors into the mounting collars. collars. c) Do not remove the red backing film, place each sensor into the holes in the bumper d) Rotate the sensor to set the sensor depth so it is flush with the bumper surface and ensure the connectors point downwards. (Max 0.5 mm protruding). IMPORTANT: Ensure you install each sensor in the hole where you made the related bumper thickness adjustment.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
6
11. Securing the sensors to the bumper (R0390) Sensor placing a) Remove the red backing film from the mounting collars. b) Fix the sensors in the bumper holes with the connector pointing pointing downwards. c) If required sensors can be rotated 180° degrees without compromising the proper functioning.
11.1 Securing the sensors to the bumper (R0290, R0190) Sensor placing a) The sensors must be inserted in the bumper with the reference mark upwards. upwards. b) They can be rotated 180° degrees without compromising the proper functioning. c) Check that the fixing wings are correctly opened, otherwise open them using a small screwdriver as shown in the picture.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
7
12. Sensor lead routing and sensor connections Sensor lead and sensor positioning a) Use an original grommet to route the sensor leads into the vehicle. b) Secure the sensor leads using the supplied tie-wraps. c) The sensor leads are numbered and must be connected from from 1 to 4 across the bumper, as shown above. d) Fit the rubber covers. IMPORTANT Ensure sensor leads are pointing downwards, as shown above.
F0190 F0290
F0390
F0390
F0290, F0190
13. Bumper reassembling and ECU positioning Bumper reassembly a) Reassemble the bumper to the vehicle. b) Pay particular attention to the sensor lead routing. c) Reconnect vehicle light connectors as applicable.
ECU positioning Position the ECU and buzzer away from each other as shown below. IMPORTANT To avoid interference, do not place the ECU and Buzzer on top of or immediately next to each other.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
8
14. System schematic (R0390) Electrical connections a) Shorten the RED RED wire wire by 20 cm. The cut off RED RED wire wire with the terminal should be kept for additional product functions, see Section 20. b) Connect the RED wire of the main harness to the reverse light wire. RED wire c) Connect the BLACK wire BLACK wire with ring terminal to vehicle ground. d) Connect Sensor lead 1 to 1 to ECU connector J2 e) Connect Sensor lead 3 to 3 to ECU connector J3
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
9
15. Reverse wire identification Reverse wire a) Locate the reverse gear engaged wire. b) Connect the RED wire. c) Ensure to insulate the solder joint.
RED wire
16. Buzzer positioning Buzzer location a) Locate a suitable position for the buzzer buzzer b) Test the buzzer volume before securing it in in position. To test the buzzer volume place an obstacle behind the bumper and engage the reverse gear. With the engine running check that the sound is audible for the driver. c) If the buzzer volume level level needs adjusting, see Section 17. d) Secure the buzzer using using the double sided sided sticky pad provided. IMPORTANT: The buzzer should not be installed close to the PARK MASTER ECU or vehicle ECU .
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
10
17.0 System programming System adjustability Four aspects of the system can be programmed; Buzzer volume, Sensor sensitivity, Side sensor distance and Central sensor distance. Enter programming a) Ignition off. b) Disconnect connectors J2 and J3 (Sensor leads). c) Turn ignition on and engage reverse gear. d) The system beeps for 2 seconds. e) Disconnect and reconnect the buzzer buzzer within the 2 seconds to enter programming mode. If during the 2 second beep the buzzer is not disconnected and reconnected again, the system will enter the self-diagnostic check, see Section 19. To exit from the self-diagnostic check turn the ignition off. f) g) h) i) j)
The system beeps 6 times to confirm it has entered the programming mode. After the 6 beeps the system beeps 1, 2, 3 and 4 times indicating the four setup functions available. The table cycles until the buzzer is disconnected. Disconnect the buzzer buzzer after hearing the number number of beeps for the function to be adjusted. When the buzzer is reconnected the system goes to the programming table of the selected function.
Main programming table 1 beep Buzzer volume (3 levels) - Standard configuration: High 2 beeps Sensors sensitivity (3 levels) - Standard configuration: Medium 3 beeps Side sensors position (3 levels) - Standard configuration: 350-440 mm 4 beeps Central sensors position (4 levels) - Standard configuration: 450-540 mm
Buzzer volume
Sensors sensitivity
Side sensors position
Central sensors position
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
11
17.1 Buzzer volume adjustment Main programming table entry 1 beep Buzzer volume (3 levels - Standard configuration: High) Buzzer volume programming table 1 beep Low volume 2 beeps Medium volume 3 beeps High volume The table cycles until the buzzer is disconnected. To choose the desired buzzer volume level disconnect and reconnect the buzzer after hearing the number of beeps you want to select. When the buzzer is reconnected the system memorizes the desired buzzer volume level and returns to the main programming table, indicated by 6 beeps, see Section 17.0.
Low
Medium
High (Standard configuration)
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
12
17.2 Sensor sensitivity adjustment Main programming table entry 2 beeps Sensor sensitivity (3 levels - Standard configuration: Medium) Sensor sensitivity programming table 1 beep Low sensitivity suitable for sensor height between 400-450 mm. 2 beeps Medium sensitivity suitable for sensor height between 450-550 mm 3 beeps High sensitivity suitable for sensor height higher than 550 mm The table cycles this sequence until the buzzer is disconnected. To choose the desired sensitivity level disconnect and reconnect the buzzer after hearing the number of beeps you want to select. When the buzzer is reconnected the system memorizes the desired sensitivity level and returns to the main programming table, indicated by 6 beeps, see Section 17.0.
Low
Medium (Standard configuration)
High
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
13
17.3 Side sensor distance adjustment Main programming table entry 3 beeps Side sensors position (3 levels) Side sensor 1 beep 2 beeps 3 beeps
distance programming table D= 250-340 mm D= 350-440 mm D= 450-540 mm
The system cycles this sequence until the buzzer is disconnected. To choose the desired side sensor distance disconnect and reconnect the buzzer after hearing the number of beeps you want to select. When the buzzer is reconnected the system memorizes the desired side sensor distance and returns to the main programming table, indicated by 6 beeps, see Section 17.0.
D= 250-340 mm
D= 350-440 mm
D= 450-540 mm
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
14
17.4 Central sensor distance adjustment Main programming table entry 4 beeps Central sensors position (4 levels) Central sensor distance programming table 1 beep D= 350-440mm 2 beeps D= 450-540 mm 3 beeps D= 550-640 mm 4 beeps D= 650-740 mm The system cycles this sequence until the buzzer is disconnected. To choose the desired central sensor distance disconnect and reconnect the buzzer after hearing the number of beeps you want to select. When the buzzer is reconnected the system memorizes the desired central sensor distance and returns to the main menu, indicated by 6 beeps, see Section 17.0.
D= 350-440 mm
D= 450-540 mm
D= 550-640 mm
D= 650-740 mm
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
15
18. System functionality check Operation check a) Position the vehicle with sensors facing a wall at a distance of approximately 1.6 m. b) Turn the ignition on and engage reverse gear. c) The system confirms its activation with 1 beep. d) Reverse towards the wall at low speed, the beep frequency will increase. e) When the vehicle is at 30 cm from the wall, the beep becomes a continuous tone.
19. Self-diagnostic check Health check The system reports any failures of sensors or the ECU with a long beep followed by beeps associated to the fault detected. The system signals any faults upon ignition on and during operation.
Sensor 1 fault
1 long beep followed by 1 beep
Contact your installer
Sensor 2 fault
1 long beep followed by 2 beeps
Contact your installer
Sensor 3 fault
1 long beep followed by 3 beeps
Contact your installer
Sensor 4 fault
1 long beep followed by 4 beeps
Contact your installer
Central unit fault
1 long beep followed by 5 beeps
Contact your installer
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
16
20. Hardware functions 20.1 Radio mute a) Insert in position 5 of the J1 connector the RED RED wire wire cut from the main harness. b) Connect the other end of the wire to the Radio mute input wire of the radio. (The output signal from the system is negative). Each time the system is activated the radio volume is lowered, thus allowing the buzzer to be heard.
8 Negative control
1
J1
20.2 Towbar ball detection avoidance a) Insert in position 1 of the J1 connector the RED RED wire wire cut from the main harness. b) Connect the other end of the wire to the vehicle ground. This will prevent the towbar ball from being detected.
8 J1
1
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
17
21. Product technical features
22. Spraying process Painting the sensors The sensors inner transducer eye itself is made from Aluminium (Pre-Coated). The F0190 and F0290 outer sensor sleeve is made from “PBT” / Valox material. The plastic masking rings ( F0190 and F0290 ) must be put over the central silic on absorber before painting. This is to prevent paint coating this part, as it would reduce the vibrati on capability of the transducer itself. Place the four sensors in the spraying tray onto a flat hoizontal surface. Insert the spacer rings provided securely in position. It is important to apply the spray in even thin coats from various angles approximately 300mm from the sensors. Use more than one coat if required, applying too much spray at one time will form ripples or gather to one edge. Apply an appropriate primer spray to each sensor and immediately REMOVE THE MASKING RINGS. Important If the masking rings are removed when the paint is dry, it will fracture the paint surface around the silicon band. Allow 20 minutes for primer primer to dry. Apply the vehicl vehicle e colour colour paint following the details described above. Remember to use thin even strokes and more than one coat with an appropriate drying period between coats. Once again REMOVE THE MASKING RINGS whilst the paint is still wet to prevent c racking. Depending on the type of vehicle body paint, it may be necessary to apply a lacquer to the surface paint.
R0190, R0290 and R0390 Installation and Configuration Guide – Rev 1
18