ED 04 - 805
- Cooling Only / Heat Pump E-Series
ED04-805
1. 2. 3. 4.
Cooling Only
FTKS25EVMA FTKS35EVMA
RKS25EBVMA RKS35EBVMA
Heat Pump
FTXS25EVMA FTXS35EVMA
RXS25EBVMA RXS35EBVMA
Features Features ................ ........................ ................ ................ .................. ................... ................. ................ ................ ................. ...............3 ......3 Power Power Supply Supply .................. ........................... ................ ............... ................. ................. ................ ................ ................. .............10 ....10 Functions.. Functions........... .................. ................. ............... ................ .................. ................... ................... ................. ................ ...............11 .......11 Specificat Specifications ions......... .................. .................. ................. ................ ................ ................. ................... ................... ..................12 .........12 4.1 Cooling Cooling Only Only .............. ..................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............12 ......12 4.2 Heat Heat Pump Pump .............. ..................... ............... ............... .............. ............... ............... .............. .............. ............... ............... .............13 ......13
5. Dimensions Dimensions ................. .......................... ................. ................ ................ ................. ................. ................ ................ ................14 ........14 5.1 Indoor Indoor Units Units ............... ...................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............14 ......14 5.2 Outdoor Outdoor Units Units .............. ..................... .............. ............... ............... .............. .............. ............... ............... .............. ............... ..........15 ..15
6. Wiring Wiring Diagrams......... Diagrams................. ................ ................ ................. ................... ................... .................. .................. ..............16 .....16 6.1 Indoor Indoor Units Units ............... ...................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............16 ......16 6.2 Outdoor Outdoor Units Units .............. ..................... .............. ............... ............... .............. .............. ............... ............... .............. ............... ..........16 ..16
7. Piping Piping Diagrams............... Diagrams........................ ................. ................ ................ ................ ................. ................. ................ ...........17 ...17 7.1 Indoor Indoor Units Units ............... ...................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............17 ......17 7.2 Outdoor Outdoor Units Units .............. ..................... .............. ............... ............... .............. .............. ............... ............... .............. ............... ..........18 ..18
8. Capacity Capacity Tables Tables ................ ........................ ................. .................. ................. ................ ................ ................. ................. .........19 .19 8.1 Cooling Cooling Only Only .............. ..................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............19 ......19 8.2 Heat Heat Pump Pump .............. ..................... ............... ............... .............. ............... ............... .............. .............. ............... ............... .............20 ......20 8.3 Capacity Capacity correct correction ion factor factor by by the length length of of refrigera refrigerant nt piping piping (Reference) (Reference) ..................................................................... ................................ ............................................................ .......................22 22
9. Operation Operation Limit..................... Limit.............................. ................... ................... .................. ................... ................... ................. .........23 .23 9.1 Cooling Cooling Only Only .............. ..................... .............. .............. .............. .............. .............. .............. .............. ............... ............... .............23 ......23 9.2 Heat Heat Pump Pump .............. ..................... ............... ............... .............. ............... ............... .............. .............. ............... ............... .............23 ......23
10.Sound Level ........................................... ....................... ........................................... ............................................. ........................24 ..24 10.1 Measuring Location................................... Location ....................................................................... .............................................24 .........24 10.2 Octave Band Level................................ Level ..................................................................... .................................................25 ............25
11.Electric Characteristics..........................................................................27 12.Installation Manual ......................................... ................... ......................................... ....................................... .................... 28 12.1 Indoor Units ..................................................................... ................................ ............................................................ .......................28 28 12.2 Outdoor Outdoor Units Units .............. ..................... .............. ............... ............... .............. .............. ............... ............... .............. ............... ..........36 ..36
13.Operation Manual..................................................................................44
Room Air Conditioners E-Series
1
ED04-805
14.Optional Accessories ............................................... ........................ .............................................. .............................70 ......70 14.1 Option Option List ............... ...................... .............. .............. .............. .............. .............. .............. ............... ............... .............. ...............7 ........70 0 14.2 Installa Installation tion Manual Manual ............... ...................... .............. ............... ............... .............. ............... ............... .............. ...............71 ........71
2
Room Air Conditioners E-Series
ED04-805
Features
1. Features
Features < Indoor Unit >
Stylish Flat Design Higher Energy Saving High Grade DC Inverter Model -DC Compressor (Reluctance DC Motor) -DC Fan Motor (both Indoor and Outdoor Unit)
< Outdoor Unit >
Quiet Sound Levels Comfortable Functions Easy Maintenance Wipe-clean Flat Panel Removable Drain Pan
Pair/Multi Compatible Indoor Unit 05RAG19A- 4
Stylish Flat Design
New Stylish Flat Design harmonizes with interiors and the simple design does not make you feel the existence of A/C in your room.
Sophisticated edge
Simple display
Straight line
05RAG19A- 5
Installation Example
05RAG19A- 6
Room Air Conditioners E-Series
3
Features
ED04-805
Swing Compressor Large Energy Savings Smooth rotation with little friction and refrigerant gas compression with little loss, allowing high operation efficiency
Low Vibrations and Low Noise Smooth piston motion as if sliding along a “groove,” resulting in low vibrations and low noise
High Durability Few parts rubbing each other during operation, achieving high performance and reliability
Reluctance DC Motor Higher efficiency with 2 different torques – magnetic torque of ND magnet and reluctance torque Distinctive effect in energy-saving running in low-frequency zone
Neodymium magnet
Ferrite magnet
05RAG19A- 11
DC Fan Motor A DC fan motor is introduced in this small class. The motor features fine rotation control and improved energy consumption.
DC motor efficiency (comparison with a conventional AC motor) 80
DC motor Approx.
) 60 % ( y c 40 Approx. n e 40% i c 20 increase i f f E
20%
increase
AC motor
0 20 0
300
400
500
600
70 0
8 00
900 1000
Motor speed (rpm)
05RAG19A- 12
ECONO Mode Decrease the Operating Current The "ECONO mode" reduces the maximum operating current and power consumption by approx. 30% during start up etc.. This mode is particularly convenient for energy-saving-orie nted users. It is also a major bonus for those whose breaking capacities do not allow the use of multiple electrical devices and air conditioners. It is easily activated from the wireless remote controller by pushing the ECONO button. Operation Image
05RAG19A- 17
4
Room Air Conditioners E-Series
ED04-805
Features
ECONO Mode Notes - When this function is ON, the maximum capacity is also down. (Approx. 20%) - In case of the multi system connection, the unit drops maximum capacity to equal level with nominal capacity in stead of current control. - This function can only be set when the unit is running. Pressing the operation stop button causes the settings to be canceled. - This function and "Powerful operation" cannot be used at the same time. (Priority is given to Powerful operation.) 05RAG19A- 18
INTELLIGENT EYE = Sensing human presence utilizing infrared rays =
Coverage Area within 7 m (Max) INTELLIGENT EYE Sensor
110˚ Max. 7m
90˚
05RAG19A- 19
INTELLIGENT EYE = Just one push of the [SENSOR] button =
ON
CANCEL
Sensor
OFF TIMER
05RAG19A- 20
Room Air Conditioners E-Series
5
Features
ED04-805
Energy Saving Functions
INTELLIGENT EYE = Automatic shift up when sensing no human, intelligently saving energy =
Cooling
e r u t a r e p m Normal e operation T
Absence
Energy Saving operation
20min
Saving 20%!
Back to normal operation when presence detected
2˚C Shift up • Minimum frequency (34Hz)
P o w e r c o n s u m p t i o n
Normal operation
Normal operation
time
Energy saving operation activated 05RAG19A- 21
INTELLIGENT EYE = When absence shift down automatically makes energy saving intelligently =
Heating • 2˚C Shift down • Minimum frequency (34Hz)
e r u t a r e p m Normal e T operation
Absence
Energy Saving operation
20min
Saving 30%!
Returns to normal operation upon sensing a sign of human
Normal operation
P o w e r c o n s u m p t i o n
Normal operation
Energy saving operation activated
time 05RAG19A- 22
6 Steps Air Flow Rate Air Flow Setting on the R/C Indoor Unit Quiet Operation
Selectable 6 steps air flow rate (5 steps and Quiet) make fine on-demand comfort. Quiet Operation for Better Sleep
SL
L ML M M H H Decrease sound level
A sound level step by step decreases approximately 2 or 3 dB by choosing smaller airflow setting.
05RAG19A- 23
6
Room Air Conditioners E-Series
ED04-805
Features
Indoor Unit Quiet Operation When air flow is set to “Quiet” through a remote controller, the operation sound of the indoor unit is reduced by 3dB. This is a convenient function while studying or sleeping. Air flow setting button
Auto
Super Low (SL)
Low (L)
Middle (M)
High (H)
Indoor unit’s fan
H
If the unit operates in “SL” or “L” mode with small air flow, operating noise is reduced but cooling / heating capacity is reduced too.
M L SL Quiet “ON”
05RAG19A- 24
Outdoor Unit Quiet Operation When QUIET button is selected, the outdoor unit’s operation sound reduces by 3dB. In night time operation, the unit can be operated with less nuisance to the neighborhood.
Outdoor Unit Quiet Operation button
Lowering the revolution speed of the compressor and fan.
3dB down 05RAG19A- 26
Mold Proof Function After cooling or dry operation, some drain water remains inside the indoor unit (on the heat exchanger, the drain pan, etc...). This moisture causes the generation of mold.
The "Mold Proof Operation" reduces the spread of mold, and decreases nasty odors that is caused by the mold.
Heat Exchanger
Drain Pan
05RAG19A- 28
Room Air Conditioners E-Series
7
Features
ED04-805
Mold Proof Function Press and hold the "MOLD PROOF" button for 2 seconds in advance. When the unit turned off after cooling or dry operation, the unit starts fan operation at a slow speed* for approximately 1 hour. The fan operation vaporizes the moisture inside the unit.
Note) * : the fan rotation speed is slower than the "Indoor Unit Quiet Operation".
05RAG19A- 29
Mold Proof Function Notes - This function is not designed to remove existing dust or mold. - This function is not available when the unit is turned off using the off timer. - During this function is operated, the flaps open a little and air the air is blown upward slightly. Fraps
05RAG19A- 30
Healthy and Clean
Titanium Apatite Photocatalytic Air-Purifying Air-Purifyi ng Filter It lasts for three years without replacement if washed about once every six months. Absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses.
ABSORB
REMOVE
05RAG19A- 31
8
Room Air Conditioners E-Series
ED04-805
Features
Wipe-clean Flat Panel Grille Type : Remove and wash the grille Current models are …
New Flat Panel : Easy to clean without removing the panel New models are … Also washable after removing the panel.
05RAG19A- 32
Room Air Conditioners E-Series
9
Power Supply
ED04-805
2. Power Su Supply
Note:
10
Indoor Units
Outdoor Units
FTKS25EVMA
RKS25EBVMA
FTKS35EVMA
RKS35EBVMA
FTXS25EVMA
RXS25EBVMA
FTXS35EVMA
RXS35EBVMA
Power Supply 1φ, 220-240V, 50Hz 1φ, 220-230V, 60Hz
Power Supply Intake ; Outdoor Unit
Room Air Conditioners E-Series
ED04-805
Functions
3. Functions Category
Basic Function
Compressor
Comfortable Airflow
Comfort Control
Operation
Lifestyle Convenience
Note:
Functions
Inverter (with Inverter Power Control)
A A M M V V B E 5 E 5 3 / 3 5 / 2 5 2 S S K T K F R
A A M M V V B E 5 E 5 3 / 3 5 / 2 5 2 S S X T X F R
Operation Limit for Cooling (°CDB)
10 ~46
10 ~46
Operation Li Limit fo for Heating (°C (°CWB)
—
–10 ~20
Category
Health & Clean
Functions
A A M M V V B E 5 E 5 3 / 3 5 / 2 5 2 S S K T K F R
A A M M V V B E 5 E 5 3 / 3 5 / 2 5 2 S S X T X F R
Air Purifying Filter
—
—
Photocatalytic Deodorizing Filter
—
—
Air Purifying Filter with Photocatalytic Photocatalytic Deodorizing Function
—
—
PAM Control
Oval Scroll Compressor
—
—
Titanium Apatite Photocatalytic Air-Purifying Filter
Swing Compressor
Mold Proof Air Filter
Rotary Compressor
—
—
Wipe-clean Flat Panel
Reluctance DC Motor
Washable Grille
—
—
Power-Airflow Flap
—
—
Mold Proof Operation
Power-Airflow Dual Flaps
Heating Dry Operation
—
—
Power-Airflow Diffuser
—
—
Good-Sleep Cooling Operation
—
—
Wide-Angle Louvers
24-Hour On/Off Timer
Vertical Auto-Swing (Up and Down)
Night Set Mode
Horizontal Au Auto-Swing (R (Right an and Le Left)
—
—
Auto-Restart (after Power Failure)
3-D Airflow
—
—
Self-Diagnosis (Digital, LED) Display
Comfort Airflow Mode
—
—
Wiring Error Check
—
—
3-Step Airflow (H/P Only)
—
—
Auto Fan Speed
Anticorrosion Treatment of Outdoor Heat Exchanger
Timer Worry Fr Free “Reliability & Durability”
Indoor Unit Quiet Operation
Night Quiet Mode (Automatic)
—
—
Flexibility
Multi-Split / Split Type Compatible Indoor Unit
Outdoor Unit Quiet Operation (Manual)
Flexible Voltage Correspondence
INTELLIGENT EYE
High Ceiling Application
—
—
Quick Warming Function
—
Chargeless
10m
1 0m
Hot-Start Function
—
Either Side Drain (Right or Left)
Automatic Defrosting
—
Power Selection
—
—
Automatic Operation
—
Programme Dry Function
5-Rooms Centralized Controller (Option)
Fan Only
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
New POWERFUL Operation (Non-Inverter)
—
—
Remote Control Adaptor (Normal Open Contact) (Option)
Inverter POWERFUL Operation
DIII-NET Compatible (Adaptor) (Option)
Priority-Room Setting
—
—
Wireless
Cooling / Heating Mode Lock
—
—
Wired
—
—
HOME LEAVE Operation
—
—
ECONO Mode
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
—
—
Another Room Operation
—
—
Remote Control
Remote Controller
: Holding Functions — : No Functions
Room Air Conditioners E-Series
11
Specifications
ED04-805
4. Specifications 4.1
Cooling Only 50Hz 220-230-240V / 60Hz 220-230V
Models
Indoor Units Outdoor Units
Moisture Removal Running Current (Rated) Power Consumption (Rated) Power Factor COP (Rated) Liquid Piping G as Connections Drain Heat Insulation Max. Interunit Piping Length Max. Interunit Height Difference Chargeless Amount of Additional Charge of Refrigerant Indoor Units Front Panel Color
g/m
20
20
mm mm kg kg
FTKS25EVMA White 8.7 (307) 6.7 (237) 4.7 (166) 3.9 (138) Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downward Removable / Washable / Mildew Proof 0.17-0.16-0.15 / 0.17-0.16 35-35-35 / 35-35 93.6-95.1-97.2 / 93.6-95.1 Microcomputer Control 283×800×195 265×855×340 9 12
FTKS35EVMA White 8.9 (314) 6.9 (244) 4.8 (169) 4.0 (141) Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downward Removable / Washable / Mildew Proof 0.19-0.18-0.17 / 0.19-0.18 40-40-40 / 40-40 95.7-96.6-98.0 / 95.7-96.6 Microcomputer Control 283×800×195 265×855×340 9 12
dBA
37/31/25/22
38/32/26/23
W A W % A mm mm kg kg
RKS25EBVMA Ivory White Hermetically Sealed Swing Type 1YC23NXD 600 FVC50K 0.375 R-410A 1.0 33.5 (1,183) 23.4 (826) Propeller 50 3.33-3.14-3.05 / 3.33-3.14 565-565-565 / 565-565 77.1-78.2-77.2 / 77.1-78.2 3.5 550×765×285 589×882×363 34 40
RKS35EBVMA Ivory White Hermetically Sealed Swing Type 1YC23NXD 600 FVC50K 0.375 R-410A 1.0 33.5 (1,183) 23.4 (826) Propeller 50 4.71-4.52-4.33 / 4.71-4.52 980-980-980 / 980-980 94.6-94.3-94.3 / 94.6-94.3 4.9 550×765×285 589×882×363 34 40
dBA
46/43
47/44
dBA
61 3D058977
62 3D058978
H M L SL
Air Flow Rate m³/min (cfm) Type Motor Output Speed Air Direction Control Air Filter Running Current (Rated) Power Consumption (Rated) Power Factor Temperature Control Dimensions (H×W×D) Packaged Dimensions (H×W×D) Weight Gross Weight Operation H/M/L/SL Sound Outdoor Units Casing Color Type Compressor Model Motor Output Type Refrigerant Oil Charge Type Refrigerant Charge m³/min Air Flow Rate (cfm) Type Fan Fan Motor Output Running Current (Rated) Power Consumption (Rated) Power Factor Starting Current Dimensions (H×W×D) Packaged Dimensions (H×W×D) Weight Gross Weight Operation H/L Sound Sound Power (H) Drawing No. Fan Fan
12
FTKS35EVMA RKS35EBVMA 3.5 (1.2~3.8) 11,900 (4,100~12,950) 3,010 (1,030~3,260) 1.9 4.9-4.7-4.5 / 4.9-4.7 1,020 (300~1,200) 94.6-94.4-94.4 / 94.6-94.4 3.43 (4.00~3.17) φ 6.4 φ 9.5 φ18.0 Both Liquid and Gas Pipes 20 15 10
kW Btu/h kcal/h L/h A W % W/W mm mm mm
Capacity Rated (Min.~Max.)
Note:
m m m
FTKS25EVMA RKS25EBVMA 2.5 (1.2~3.0) 8,500 (4,100~10,200) 2,150 (1,030~2,580) 1.2 3.5-3.3-3.2 / 3.5-3.3 600 (300~800) 77.9-79.1-78.1 / 77.9-79.1 4.17 (4.00~3.75) φ 6.4 φ 9.5 φ18.0 Both Liquid and Gas Pipes 20 15 10
W Steps
A W %
W L kg H L
The data are based on the conditions shown in the table below. Cooling Piping Length Indoor ; 27°CDB/19°CWB 7.5m Outdoor ; 35°CDB/24°CWB
Conversion Formulae kcal/h=kW×860 Btu/h=kW×3414 cfm=m³/min×35.3
Room Air Conditioners E-Series
ED04-805
4.2
Specifications
Heat Pump 50Hz 220-230-240V / 60Hz 220-230V Indoor Units
Models
FTXS25EVMA RXS25EBVMA
Outdoor Units kW Btu/h kcal/h L/h A W % W/W mm mm mm
Capacity Rated (Min.~Max.) Moisture Removal Running Current (Rated) Power Consumption (Rated) Power Factor COP (Rated) Liquid Piping Connections Gas Drain Heat Insulation Max. Interunit Piping Length Max. Interunit Height Difference Chargeless Amount of Additional Charge of Refrigerant Indoor Units Front Panel Color
Heating 3.4 (1.2~4.5) 11,600 (4 (4,100~15,350) 2,920 (1,030~3,870) — 4.3-4.1-3.9 / 4.3-4.1 830 (290~1,340) 87.7-88.0-88.7 / 87.7-88.0 4.10 (4.14~3.36) φ 6.4 φ 9.5 φ18.0 Both Liquid and Gas Pipes 20 15 10
g/m
H M L SL
Type Motor Output Speed Air Direction Control Air Filter Running Current (Rated) Power Consumption (Rated) Power Factor Temperature Control Dimensions (H×W×D) Packaged Dimensions (H×W×D) Weight Gross Weight Operation H/M/L/SL Sound Outdoor Units Casing Color Type Compressor Model Motor Output T ype Refrigerant Oil Charge Type Refrigerant Charge Fan Fan
W Steps
A W % mm mm kg kg dBA
W L kg H L
Air Flow Flow Rate Rate m³/min m³/min (cfm) (cfm) Type Motor Output Running Current (Rated) Power Consumption (Rated) Power Factor Starting Current Dimensions (H×W×D) Packaged Dimensions (H×W×D) Weight Gross Weight Operation H/L Sound Sound Power (H) Drawing No. Fan Fan
Note:
Cooling 2.5 (1.2~3.0) 8,500 (4 (4,100~10,200) 2,150 (1,030~2,580) 1.2 3.5-3.3-3.2 / 3.5-3.3 600 (300~800) 77.9-79.1-78.1 / 77.9-79.1 4.17 (4.00~3.75)
m m m
Air Flow Rate m³/min (cfm)
W A W % A mm mm kg kg
FTXS35EVMA RXS35EBVMA
20
FTXS25EVMA White
FTXS35EVMA White 9.4 (332) 7.6 (268) 5.8 (205) 5.0 (177)
8.9 (314) 6.9 (242) 4.8 (169) 4.0 (141)
Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downward Removable / Washable / Mildew Proof 0.17-0.16-0.15 / 0.17-0.16 0.17-0.16-0.15 / 0.17-0.16 35-35-35 / 35-35 35-35-35 / 35-35 93.6-95.1-97.2 / 93.6-95.1 93.6-95.1-97.2 / 93.6-95.1 Microcomputer Control 283×800×195 265×855×340 9 12 37/31/25/22
dBA
—
38/32/26/23
47/44
47/44
62
—
The data are based on the conditions shown in the table below. Cooling Heating Indoor ; 27°CDB/19°CWB Indoor ; 20°CDB Outdoor ; 35°CDB/24°CWB Outdoor ; 7°CDB/6°CWB
Room Air Conditioners E-Series
38/34/29/26
RXS35EBVMA Ivory White Hermetically Sealed Swing Type 1YC23NXD 600 FVC50K 0.375 R-410A 1.0 33.5 (1,183) 30.2 (1,066) 23.4 (826) 28.3 (999) Propeller 50 4.71-4.52-4.33 / 4.71-4.52 4.91-4.72-4.53 / 4.91-4.72 1,040-1,040-1,040 / 1,040-1,040 980-980-980 / 980-980 94.6-94.3-94.3 / 94.6-94.3 96.3-95.8-95.7 / 96.3-95.8 5.1 550×765×285 589×882×363 34 40
3D058979
9.7 (342) 7.9 (277) 6.0 (212) 5.2 (184)
Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downward Removable / Washable / Mildew Proof 0.19-0.18-0.17 / 0.19-0.18 0.19-0.18-0.17 / 0.19-0.18 40-40-40 / 40-40 40-40-40 / 40-40 95.7-96.6-98.0 / 95.7-96.6 95.7-96.6-98.0 / 95.7-96.6 Microcomputer Control 283×800×195 265×855×340 9 12
37/33/28/25
RXS25EBVMA Ivory White Hermetically Sealed Swing Type 1YC23NXD 600 FVC50K 0.375 R-410A 1.0 33.5 (1,183) 30.2 (1,066) 23.4 (826) 28.3 (999) Propeller 50 3.33-3.14-3.05 / 3.33-3.14 4.13-3.94-3.75 / 4.13-3.94 565-565-565 / 565-565 795-795-795 / 795-795 77.1-78.2-77.2 / 77.1-78.2 87.5-87.7-88.3 / 87.5-87.7 4.3 550×765×285 589×882×363 34 40 46/43
Heating 4.0 (1.2~5.0) 13,600 (4 (4,100~17,050) 3,440 (1,030~4,300) — 5.1-4.9-4.7 / 5.1-4.9 1,080 (290~1,550) 96.3-95.8-95.7 / 96.3-95.8 3.70 (4.14~3.23) φ 6.4 φ 9.5 φ18.0 Both Liquid and Gas Pipes 20 15 10
20
8.7 (307) 6.7 (237) 4.7 (166) 3.9 (138)
dBA
Cooling 3.5 (1.2~3.8) 11,900 (4 (4,100~12,950) 3,010 (1,030~3,260) 1.9 4.9-4.7-4.5 / 4.9-4.7 1,020 (300~1,200) 94.6-94.4-94.4 / 94.6-94.4 3.43 (4.00~3.17)
48/45 63 3D058980
Piping Length
Conversion Formulae
7.5m
kcal/h=kW×860 Btu/h=kW×3414 cfm=m³/min×35.3
13
Dimensions
ED04-805
5. Dimensions 5.1
Indoor Units
FTKS25/35EVMA THE MARK ( →) SHOWS PIPING DIRECTION REAR
) E C R N O A . F M N E R I O M C F 0 A R 3 P S E ( P
AIR FLOW(INDOOR )
800 RIGHT
LEFT
INCLUDING ( MOUNTING PLATE ) 197
50MIN.
50MIN.
(SPACEFOR MAINTENANCE)
195
(SPACE FOR MAINTENANCE)
REQUIRED SPACE
SIGNAL RECEIVER NAME PLATE OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP
3 8 2
TERMINAL BLOCK WITH EARTH TERMINAL
INTELLIGENT EYE SENSOR BOTTOM
GAS PIPE 9.5Cut (THE LENGTH OF PIPE OUTSIDE THE UNIT:ABOUT390)
INDOOR UNIT ON/OFF SWITCH FRONT PANEL FIXED SCREWS FLAPS ( INSIDE )
ROOM TEMP. THERMISTOR( INSIDE )
LIQUID PIPE 6.4CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT:ABOUT 340)
SIGNAL TRANSMITTER
DRAIN HOSE (CONNECTING PART I. D. φ14 O. D.φ18 THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX. 440)
800 58
7 1
BLADE ANGLE
18
711
49
3 1
UP/DOWN( AUTOMATIC )
DAIKIN
FAN
COOLING, DRY 3 6 1
0 8 1 3 8 2
5 . 4 4
5°
10°
60 50°
WIRELESS REMOTE CONTROLLER
WALL HOLE FOR EMBEDDED PIPING φ65 HOLE
70°
STANDARD LOCATIONS OF WALL HOLES
RIGHT/LEFT( MANUAL )
5 . 4 4
110
WALL HOLE φ65 HOLE
( ARC433B47 ) 4 5 °
3D047958E
° 4 5
FTXS25/35EVMA THE MARK ( →) SHOWS PIPING DIRECTION REAR
) E R C O N . F A N E M I C R M O 0 A P F 3 S R ( E P
AIR FLOW( INDOOR )
800 RIGHT
LEFT
INCLUDING ( MOUNTING PLATE ) 197
50MIN.
50MIN.
( SPACE FOR MAINTENANCE )
195
( SPACE FOR MAINTENANCE )
REQUIRED SPACE
SIGNAL RECEIVER NAME PLATE OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP
3 8 2
TERMINAL BLOCK WITH EARTH TERMINAL
INTELLIGENT EYE SENSOR BOTTOM
GAS PIPE 9.5Cut ( THE LENGTH OF PIPE OUTSIDE THEUNIT:ABOUT390 )
INDOOR UNIT ON/OFF SWITCH FRONT PANEL FIXED SCREWS FLAPS ( INSIDE )
ROOM TEMP. THERMISTOR( INSIDE )
LIQUID PIPE 6.4CuT ( THE LENGTH OF PIPE OUTSIDE THE UNIT:ABOUT 340 )
SIGNAL TRANSMITTER
DRAIN HOSE ( CONNECTING PART I. D.φ14 O. D. φ18 THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX. 440 )
800 58
7 1
BLADE ANGLE
18
711
49
3 1
UP/DOWN( AUTOMATIC ) DAIKIN
COOLING, DRY
HEATING
3 6 1
0 8 1 3 8 2
5 . 4 4
FAN
5°
10°
60 30°
50°
65°
WIRELESS REMOTE CONTROLLER
RIGHT/LEFT( MANUAL )
70°
110
WALL HOLE FOR EMBEDDED PIPING φ65 HOLE
STANDARD LOCATIONS OF WALL HOLES
5 . 4 4
WALL HOLE φ65 HOLE
( ARC433B46 ) 4 5 °
14
° 4 5
3D047956D
Room Air Conditioners E-Series
ED04-805
5.2
Dimensions
Outdoor Units
RK(X)S25/35EBVMA
4 - HOLES FOR ANCHOR BOLTS (M8 OR M10)
DRAIN OUTLET (I.D φ15.9 HOSE FOR CONNECTION) 574
MINIMUM SPACE FOR AIR PASSAGE
0 5 1
105.5 490
3 1
0 0 1 5 . 9 2
1 1 3
WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 1200
0 5 1
50
50
0 5
HANDLE
50
0 0 3
0 0 1
BRAND NAME LABEL 285
8
12
765
63
OUTDOOR AIR THERMISTOR MANUFACTURE'S LABEL
LIQUID STOP VALVE (φ6.4CuT)
WIRING INLET
0 5 5
SERVICE PORT
5 5 6 0 1 1
196 INDICATION INDICATION LABEL
IN CASE OF REMOVING STOP VALVE COVER
22
GAS STOP VALVE (φ9.5CuT)
3D059795
Room Air Conditioners E-Series
15
Wiring Diagrams
ED04-805
6. Wirin iring g Diagr iagram ams s 6.1
Indoor Units
FTK(X)S25/35EVMA
FIELD WIRING. PCB3
S27
S26
PCB1
~
F1U
~ RECTIFIER
LED1
H1
1
3.15A
X1M
V1
H1P
H2
LED2 H2P LED3 H3P
1
WHT
2
RED
3
2 3
FG S1W 7
S21
t°
S1 RED
HA
R1T
PCB4
S36
BRN ORG WHT
1
INTELLIGENT EYE SENSOR
S28
S32
PCB2
1
S6
M M1F
5
: : : : : : : : : : :
D G W K U E R L N L R O Y P B
t° S29
WIRELESS REMOTE CONTROLLER
FG F1U H1P~H3P M1F M1S PCB1~PCB PCB1~PCB4 4 R 1T 1T, R 2T 2T S1~S38 S1W X1M
BLU
S35
OUTDOOR
CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.
GRN / YLW
H3
TRANSMISSION CIRCUIT
BLK
FRAME GROUND FUSE PI PILOT LAMP FAN MOTOR SWING MOTOR PRINTED PRINTED CIRCUIT CIRCUIT BOARD BOARD TH TH E ER RM IS IS TO R. R. CONNECTOR OP OPERATION SWITCH TE TERMINAL STRIP PROTECTIV E EARTH
R2T
SIGNAL RECEIVER
INDOOR
M M1S
3D046453B
6.2
Outdoor Units
RK(X)S25/35EBVMA R12T
t°
BRN
K K L L B B
C100
indoor
FIELD WIRING.
HC2 FU3 Z2C HL1 20A
X1M
1 2 3
L 1 N 2 3
BLK WHT
PCB1
MRM20
L1
S
V2
HN2
E 7
HC3
+
GRY
HN3
BLU
1
DB2 ~ +
~ _
C74
+ _
C94
+ _
FU2 3.15A
~ _
FU1
IC11
3.15A
C75
+ _
+ _ C95
7
PCB2
MRCW S20
6
1
1
3
S90
S70 6
1 2 34
NOTE 1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
1
16
: CAPACITOR : DIODE BRIDGE : FUSE : TRIAC : INTELLIGENT POWER MODULE : LIVE : COIL : REACTOR : COMPRESSOR MOTOR : FAN MOTOR : MAGNETIC RELAY
2
T W G U N D H L R L R E Y B R W O B
K K K K K K L L L L L L B B B B B B
T N U D H G R R L E W O B B R
S30 5
1
K Y L R B G
3
1
U W D L L E B Y R
3
S80 C74, C75 C94, C95, C100 DB1, DB2 FU1, FU2, FU3 IC11 IPM1 L L1 L1R M1C M1F MRCW, MRM10, MRM20
S40
7
S80
outdoor
_ W V U
V1
S10
1
IPM1
HC4
HR2 DB1 ~ +
HL3 WHT BLK BLK BLK BLK BLK BLK
V3
ORG
ORG
S11 1
W L Y / N R G W L Y / N R G
HL2
MRM10
SA1
L N
L1R HR1
HN1
RED
YLW
HC1
IN CASE OF COOLING ONLY TYPE N PCB1, PCB2 Q1L R1T, R2T, R3T, R12T S10, S11, S20 S30, S40, S70 S80, S90, S91 HC3, HC4, HL3, HN3
t°
Y1R M
Y1E
IN CASE OF HEAT PUMP TYPE
: NEUTRAL : PRINTED CIRCUIT BOARD : OVERLOAD PROTECTOR : THERMISTOR
: CONNECTOR
t°
t°
R1T R2T R3T (OUTDOOR) (DISCHARGE) (CONDENSER)
SA1 V1, V2, V3 X1M Y1E Y1R Z1C, Z2C
M 1~
V
M1F
Q1L
: SURGE ARRESTER : VARISTOR : TERMINAL STRIP : ELECTRONIC EXPANSION VALVE COIL : REVERSING SOLENOIDE VALVE COIL : FERRITE CORE : PROTECTIVE EARTH
W
Z1C N=2 U
M1C
3D046707L
Room Air Conditioners E-Series
ED04-805
Piping Diagrams
7. Pipin iping g Diag Diagra ram ms 7.1
Indoor Units FTXS25/35EVMA
FTKS25/35EVMA
INDOOR UNIT
INDOOR UNIT
MAFFLER ASSY HEAT EXCHANGER 7.0CuT
MAFFLER ASSY HEAT EXCHANGER 7.0CuT
6.4CuT
6.4CuT
THERMISTOR T ON HEAT EXCH. u C 9 . 7
FIELD PIPING (6.4CuT)
6.4CuT
T u C 9 . 7
6.4CuT
CROSS FLOW FAN FIELD PIPING (6.4CuT)
M FAN MOTOR
FIELD PIPING (9.5CuT)
6.4CuT 6.4CuT
CROSS FLOW FAN
M FAN MOTOR
9.5CuT
FIELD PIPING (9.5CuT) 9.5CuT)
REFRIGERANT FLOW COOLING
4D050757B
Room Air Conditioners E-Series
THERMISTOR ON HEAT EXCH.
9.5CuT
REFRIGERANT FLOW COOLING HEATING
4D047912J
17
Piping Diagrams
ED04-805
7.2
Outdoor Units
7.2.1
Cooling Only
RKS25/35EBVMA OUTDOOR UNIT OUTDOOR TEMPERATURE THERMISTOR
7.0CuT HEAT EXCHANGER T u C 5 . 9
7.0CuT HEAT EXCHANGER THERMISTOR 4.8CuT 6.4C 6.4CuT uT 6.4C 6.4CuT uT 4.8CuT MUFFLER WITH FILTER
M
MOTOR OPERATED VALVE
MUFFLER WITH FILTER
PROPELLER FAN
T u C 5 . 9
T u C 0 . 2 . D I × 0 . 4 . φ
9.5CuT
FOUR WAY T u VALVE C 9 . NORMALLY : OFF 7
MUFFLER WITH TFILTER u C 4 . 6 T u C 5 . 9
LIQUID STOP VALVE
MUFFLER DISCHARGE PIPE THERMISTOR T u C 9 . COMPRESSOR 7
9.5CuT
9.5CuT GAS STOP VALVE
MUFFLER
ACCUMULATOR
FIELD PIPING (6.4CuT) 6.4CuT)
FIELD PIPING (9.5CuT) 9.5CuT) REFRIGERANT FLOW COOLING 3D047318F
7.2.2
Heat Pump
RXS25/35EBVMA OUTDOOR UNIT OUTDOOR TEMPERATURE THERMISTOR
7.0CuT HEAT EXCHANGER T u C 5 . 9
7.0CuT HEAT EXCHANGER THERMISTOR 4.8CuT 6.4C 6.4CuT uT 6.4C 6.4CuT uT 4.8CuT MUFFLER WITH FILTER
M T u C 5 . 9
MOTOR OPERATED VALVE
MUFFLER WITH FILTER
PROPELLER FAN
T u C 0 . 2 . D I × 0 . 4 . φ
9.5CuT
FOUR WAY T u VALVE C ON : HEATING 9 . 7 MUFFLER
DISCHARGE PIPE THERMISTOR
T u CCOMPRESSOR 9 . 7
MUFFLER WITH FILTER T u C 4 . 6 T u C 5 . 9
LIQUID STOP VALVE
9.5CuT ACCUMULATOR
9.5CuT MUFFLER
GAS STOP VALVE
FIELD PIPING (6.4CuT) 6.4CuT)
FIELD PIPING (9.5CuT) 9.5CuT) REFRIGERANT FLOW COOLING HEATING 3D047316J
18
Room Air Conditioners E-Series
ED04-805
Capacity Tables
8. Capa apacity city Table ables s 8.1
Cooling Only
FTKS25EVMA + RKS25EBVMA (50Hz 220-230-240V / 60Hz 220-230V) AFR
8.7
BF
0.24 OUTDOOR TEMPERATURE(°CDB)
INDOOR EWB
EDB
20 TC
SH C
25 PI
TC
S HC
30 PI
TC
SH C
32 PI
TC
35
SH C
PI
TC
S HC
40 PI
TC
kW
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
14.0 14.0
20
2.56 2.56
1.93 1.93
0.46 0.46
2.44 2.44
1.87 1.87
0.50 0.50
2.33 2.33
1.82 1.82
0.55 0.55
2.28 2.28
1.79 1.79
0.57 0.57
2.21 2.21
1.76 1.76
0.59 0.59
2.10 2.10
1.70 1.70
0.64 0.64
16.0 16.0
22
2.68 2.68
1.90 1.90
0.46 0.46
2.56 2.56
1.84 1.84
0.51 0.51
2.44 2.44
1.79 1.79
0.55 0.55
2.40 2.40
1.77 1.77
0.57 0.57
2.33 2.33
1.74 1.74
0.60 0.60
2.21 2.21
1.69 1.69
0.64 0.64
18.0 18.0
25
2.79 2.79
1.99 1.99
0.47 0.47
2.68 2.68
1.94 1.94
0.51 0.51
2.56 2.56
1.89 1.89
0.55 0.55
2.51 2.51
1.87 1.87
0.57 0.57
2.44 2.44
1.84 1.84
0.60 0.60
2.33 2.33
1.80 1.80
0.64 0.64
19.0 19.0
27
2.85 2.85
2.11 2.11
0.47 0.47
2.73 2.73
2.06 2.06
0.51 0.51
2.62 2.62
2.01 2.01
0.56 0.56
2.57 2.57
1.99 1.99
0.57 0.57
2.50 2.50
1.96 1.96
0.60 0.60
2.38 2.38
1.92 1.92
0.64 0.64
22.0 22.0
30
3.02 3.02
2.03 2.03
0.47 0.47
2.91 2.91
1.99 1.99
0.52 0.52
2.79 2.79
1.95 1.95
0.56 0.56
2.74 2.74
1.93 1.93
0.58 0.58
2.67 2.67
1.91 1.91
0.60 0.60
2.56 2.56
1.86 1.86
0.65 0.65
24.0 24.0
32
3.14 3.14
1.98 1.98
0.47 0.47
3.02 3.02
1.94 1.94
0.52 0.52
2.90 2.90
1.90 1.90
0.56 0.56
2.86 2.86
1.89 1.89
0.58 0.58
2.79 2.79
1.86 1.86
0.61 0.61
2.67 2.67
1.83 1.83
0.65 0.65
Symbols
kW
SHC
kW
NOTE:
AFR
: Air flow rate
(m³/min.)
BF
: Bypass factor
EWB
: En Entering we wet bu bulb te temp.
1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5m Level difference : 0m 2. shows shows nomina nominall (rat (rated) ed) capaci capacitie ties s and and power power input. input.
(°C (°C)
EDB
: Entering dry bulb temp.
(°C (°C)
TC
: Total capacity
(kW)
SHC
: Sensible heat capacity
(kW)
PI
: Power input
(kW) 3D054239A
FTKS35EVMA + RKS35EBVMA (50Hz 220-230-240V / 60Hz 220-230V) AFR
8.9
BF
0.24 OUTDOOR TEMPERATURE(°CDB)
INDOOR
20
25
30
32
35
40
EWB
EDB
TC
SH C
PI
TC
S HC
PI
TC
SH C
PI
TC
SH C
PI
TC
S HC
PI
TC
SHC
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
14.0 14.0
20
3.31 3.31
2.33 2.33
0.78 0.78
3.31 3.31
2.33 2.33
0.86 0.86
3.26 3.26
2.31 2.31
0.93 0.93
3.19 3.19
2.27 2.27
0.96 0.96
3.10 3.10
2.22 2.22
1.01 1.01
2.93 2.93
2.13 2.13
1.08 1.08
16.0 16.0
22
3.75 3.75
2.44 2.44
0.79 0.79
3.58 3.58
2.35 2.35
0.86 0.86
3.42 3.42
2.27 2.27
0.94 0.94
3.36 3.36
2.24 2.24
0.97 0.97
3.26 3.26
2.19 2.19
1.01 1.01
3.10 3.10
2.11 2.11
1.09 1.09
18.0 18.0
25
3.91 3.91
2.52 2.52
0.79 0.79
3.75 3.75
2.44 2.44
0.87 0.87
3.58 3.58
2.37 2.37
0.94 0.94
3.52 3.52
2.34 2.34
0.97 0.97
3.42 3.42
2.29 2.29
1.02 1.02
3.26 3.26
2.22 2.22
1.09 1.09
19.0 19.0
27
3.99 3.99
2.63 2.63
0.79 0.79
3.83 3.83
2.55 2.55
0.87 0.87
3.66 3.66
2.48 2.48
0.94 0.94
3.60 3.60
2.45 2.45
0.97 0.97
3.50 3.50
2.41 2.41
1.02 1.02
3.34 3.34
2.33 2.33
1.10 1.10
22.0 22.0
30
4.23 4.23
2.53 2.53
0.80 0.80
4.07 4.07
2.46 2.46
0.88 0.88
3.90 3.90
2.39 2.39
0.95 0.95
3.84 3.84
2.37 2.37
0.98 0.98
3.74 3.74
2.33 2.33
1.03 1.03
3.58 3.58
2.26 2.26
1.10 1.10
24.0 24.0
32
4.39 4.39
2.45 2.45
0.81 0.81
4.23 4.23
2.39 2.39
0.88 0.88
4.07 4.07
2.33 2.33
0.96 0.96
4.00 4.00
2.30 2.30
0.99 0.99
3.90 3.90
2.27 2.27
1.03 1.03
3.74 3.74
2.21 2.21
1.11 1.11
Symbols
NOTE:
AFR
: Air flow rate
(m³/min.)
BF
: Bypass factor
EWB
: En Entering we wet bu bulb te temp.
(°C (°C)
EDB
: Entering dry bulb temp.
(°C (°C)
TC
: Total capacity
(kW)
SHC
: Sensible heat capacity
(kW)
PI
: Power input
(kW)
1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5m Level difference : 0m 2. shows shows nomina nominall (rat (rated) ed) capaci capacitie ties s and and power power input. input.
3D054240A
Room Air Conditioners E-Series
19
Capacity Tables
8.2
ED04-805
Heat Pump
FTXS25EVMA+ RXS25EBVMA (50Hz 220-230-240V / 60Hz 220-230V) Cooling AFR
8.7
BF
0.24
OUTDOOR TEMPERATURE(°CDB)
INDOOR
20
25
30
32
35
40
EWB
EDB
TC
SH C
PI
TC
S HC
PI
TC
SH C
PI
TC
SH C
PI
TC
S HC
PI
TC
SHC
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
14.0 14.0
20
2.56 2.56
1.93 1.93
0.46 0.46
2.44 2.44
1.87 1.87
0.50 0.50
2.33 2.33
1.82 1.82
0.55 0.55
2.28 2.28
1.79 1.79
0.57 0.57
2.21 2.21
1.76 1.76
0.59 0.59
2.10 2.10
1.70 1.70
0.64 0.64
16.0 16.0
22
2.68 2.68
1.90 1.90
0.46 0.46
2.56 2.56
1.84 1.84
0.51 0.51
2.44 2.44
1.79 1.79
0.55 0.55
2.40 2.40
1.77 1.77
0.57 0.57
2.33 2.33
1.74 1.74
0.60 0.60
2.21 2.21
1.69 1.69
0.64 0.64
18.0 18.0
25
2.79 2.79
1.99 1.99
0.47 0.47
2.68 2.68
1.94 1.94
0.51 0.51
2.56 2.56
1.89 1.89
0.55 0.55
2.51 2.51
1.87 1.87
0.57 0.57
2.44 2.44
1.84 1.84
0.60 0.60
2.33 2.33
1.80 1.80
0.64 0.64
19.0 19.0
27
2.85 2.85
2.11 2.11
0.47 0.47
2.73 2.73
2.06 2.06
0.51 0.51
2.62 2.62
2.01 2.01
0.56 0.56
2.57 2.57
1.99 1.99
0.57 0.57
2.50 2.50
1.96 1.96
0.60 0.60
2.38 2.38
1.92 1.92
0.64 0.64
22.0 22.0
30
3.02 3.02
2.03 2.03
0.47 0.47
2.91 2.91
1.99 1.99
0.52 0.52
2.79 2.79
1.95 1.95
0.56 0.56
2.74 2.74
1.93 1.93
0.58 0.58
2.67 2.67
1.91 1.91
0.60 0.60
2.56 2.56
1.86 1.86
0.65 0.65
24.0 24.0
32
3.14 3.14
1.98 1.98
0.47 0.47
3.02 3.02
1.94 1.94
0.52 0.52
2.90 2.90
1.90 1.90
0.56 0.56
2.86 2.86
1.89 1.89
0.58 0.58
2.79 2.79
1.86 1.86
0.61 0.61
2.67 2.67
1.83 1.83
0.65 0.65
Heating AFR
9.4
OUTDOOR TEMPERATURE(°CWB)
INDOOR ED B
–10
–5
TC
PI
TC
0 PI
TC
6 PI
TC
10 PI
TC
PI
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
15.0
2.29
0.70
2.67
0.74
3.06
0.77
3.52
0.81
3.82
0.84
20.0
2.17
0.72
2.56
0.75
2.94
0.79
3.40
0.83
3.71
0.86
22.0
2.12
0.73
2.51
0.76
2.89
0.80
3.35
0.84
3.66
0.86
24.0
2.08
0.74
2.46
0.77
2.85
0.80
3.31
0.84
3.61
0.87
25.0
2.05
0.74
2.44
0.77
2.82
0.81
3.28
0.85
3.59
0.88
27.0
2.01
0.75
2.39
0.78
2.77
0.82
3.24
0.86
3.54
0.88
Symbols
NOTE:
AFR
: Air flow rate
(m³/min.)
BF
: Bypass factor
EWB
: En Entering we wet bu bulb te temp.
(°C (°C)
EDB
: Entering dry bulb temp.
(°C (°C)
TC
: Total capacity
(kW)
SHC
: Sensible heat capacity
(kW)
PI
: Power input
(kW)
1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5m Level difference : 0m 2. shows shows nomina nominall (rat (rated) ed) capac capaciti ities es and power power input. input.
3D054237A
20
Room Air Conditioners E-Series
ED04-805
Capacity Tables
FTXS35EVMA + RXS35EBVMA (50Hz 220-230-240V / 60Hz 220-230V) Cooling AFR
8.9
BF
0.24
OUTDOOR TEMPERATURE(°CDB)
INDOOR
20
25
30
32
35
40
EWB
EDB
TC
SH C
PI
TC
S HC
PI
TC
SH C
PI
TC
SH C
PI
TC
S HC
PI
TC
SHC
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
14.0 14.0
20
3.31 3.31
2.33 2.33
0.78 0.78
3.31 3.31
2.33 2.33
0.86 0.86
3.26 3.26
2.31 2.31
0.93 0.93
3.19 3.19
2.27 2.27
0.96 0.96
3.10 3.10
2.22 2.22
1.01 1.01
2.93 2.93
2.13 2.13
1.08 1.08
16.0 16.0
22
3.75 3.75
2.44 2.44
0.79 0.79
3.58 3.58
2.35 2.35
0.86 0.86
3.42 3.42
2.27 2.27
0.94 0.94
3.36 3.36
2.24 2.24
0.97 0.97
3.26 3.26
2.19 2.19
1.01 1.01
3.10 3.10
2.11 2.11
1.09 1.09
18.0 18.0
25
3.91 3.91
2.52 2.52
0.79 0.79
3.75 3.75
2.44 2.44
0.87 0.87
3.58 3.58
2.37 2.37
0.94 0.94
3.52 3.52
2.34 2.34
0.97 0.97
3.42 3.42
2.29 2.29
1.02 1.02
3.26 3.26
2.22 2.22
1.09 1.09
19.0 19.0
27
3.99 3.99
2.63 2.63
0.79 0.79
3.83 3.83
2.55 2.55
0.87 0.87
3.66 3.66
2.48 2.48
0.94 0.94
3.60 3.60
2.45 2.45
0.97 0.97
3.50 3.50
2.41 2.41
1.02 1.02
3.34 3.34
2.33 2.33
1.10 1.10
22.0 22.0
30
4.23 4.23
2.53 2.53
0.80 0.80
4.07 4.07
2.46 2.46
0.88 0.88
3.90 3.90
2.39 2.39
0.95 0.95
3.84 3.84
2.37 2.37
0.98 0.98
3.74 3.74
2.33 2.33
1.03 1.03
3.58 3.58
2.26 2.26
1.10 1.10
24.0 24.0
32
4.39 4.39
2.45 2.45
0.81 0.81
4.23 4.23
2.39 2.39
0.88 0.88
4.07 4.07
2.33 2.33
0.96 0.96
4.00 4.00
2.30 2.30
0.99 0.99
3.90 3.90
2.27 2.27
1.03 1.03
3.74 3.74
2.21 2.21
1.11 1.11
Heating AFR
9.7
OUTDOOR TEMPERATURE(°CWB)
INDOOR
–10
–5
0
6
10
ED B
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
15.0
2.69
0.91
3.14
0.96
3.60
1.00
4.14
1.06
4.50
1.09
20.0
2.55
0.94
3.01
0.98
3.46
1.03
4.00
1.08
4.36
1.12
22.0
2.50
0.95
2.95
0.99
3.40
1.04
3.94
1.09
4.31
1.13
24.0
2.44
0.96
2.90
1.00
3.35
1.05
3.89
1.10
4.25
1.14
25.0
2.42
0.96
2.87
1.01
3.32
1.05
3.86
1.10
4.22
1.14
27.0
2.36
0.97
2.81
1.02
3.26
1.06
3.81
1.11
4.17
1.15
Symbols
NOTE:
AFR
: Air flow rate
(m³/min.)
BF
: Bypass factor
EWB
: En Entering we wet bu bulb te temp.
(°C (°C)
EDB
: Entering dry bulb temp.
(°C (°C)
TC
: Total capacity
(kW)
SHC
: Sensible heat capacity
(kW)
PI
: Power input
(kW)
1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5m Level difference : 0m 2. shows shows nomina nominall (rat (rated) ed) capac capaciti ities es and power power input. input.
3D054238A
Room Air Conditioners E-Series
21
Capacity Tables
8.3
ED04-805
Capacit Capacity y correcti correction on factor factor by the length length of refriger refrigerant ant piping piping (Refere (Reference nce)) The cooling and the heating capacity of the unit has to be corrected in accordance with the length of refrigerant piping. (The distance between the indoor unit and the outdoor unit) <— line : cooling capacity> <--- line : heating capacity>
R-410A (25/35 class) 1
r o t c a f n o i t c e r r o c y t i c a p a C
0.9
Range of the refrigerant additional charge
0.8
5
10
15
20
Piping length (m) (R4979)
Note:
22
The graph shows the factor when additional refrigerant of the proper quantity is charged.
Room Air Conditioners E-Series
ED04-805
Operation Limit
9. Operati ratio on Lim Limit 9.1
Cooling Only
RKS25/35EBVMA
50 46 ) 40 B D C ° ( . p 30 m e t r o o d t u O 20
n o i t a r e p o s u o u n i t n o C
d o i r e p n w o d l l u P
10
10
14 20 23 Indoor temp.( temp.( °CWB) CWB)
Notes: The graph is based on the following conditions. Equiv valen alentt pip pipin ing g len lengt gth h • Equi • Level difference • Air flow rate
2830
7.5m 7.5m 0m High 4D050467G
9.2
Heat Pump
RXS25/35EBVMA Heating
Cooling 20
15 50 46 ) 40 B D C ( . p m 30 e t r o o d t u O 20
) B 10 W C ( . p m e 5 t r o o d t u O °
n o i t a r e p o s u o u n i t n o C
°
d o i r e p n w o d l l u P
0
n o i t a r e p o s u o u n i t n o C
-5 10 -10 (-10°CDB) 10
14 2 0 23 Indoor temp.(°CWB)
2830 Notes: The graphs are based on the following conditions. • Equi Equiv valen alentt pip pipin ing g len lengt gth h • Level difference • Air flow rate
Room Air Conditioners E-Series
10 20 Indoor temp.( temp.(°CDB) CDB) 7.5m 7.5m 0m H i gh
30
3D050466E
23
Sound Level
ED04-805
10.Soun 10. Sound d Level 10.1 10.1 Measu easuri ring ng Lo Loca cati tion on Indoor Unit
Outdoor Unit
1m
1m
m 8 . 0
(R4287)
(R4286)
Note:
1. Operation Operation sound is measure measured d in an anechoic anechoic chamber. chamber. 2. The data are are based on on the conditions conditions shown shown in the table below. below. Cooling Indoor ; 27°CDB/19°CWB Outdoor ; 35°CDB/24°CWB
24
Heating Indoor ; 20°CDB Outdoor ; 7°CDB/6°CWB
Piping Length 5m
Room Air Conditioners E-Series
ED04-805
Sound Level
10.2 10.2 Octav ctave e Ba Band Lev Level 10.2 10.2.1 .1 Indo Indoor or Unit Units s FTKS25EVMA
FTKS35EVMA
70
70
OVER ALL ( dB ) 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L)
NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N 30 A d B E V A T C 20 APPROXIMATE O
A
NC-50
37
25
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V (H) 50/60Hz 220-240/220-230V (L)
NC-20
50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (L) (H)
NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N d30 A B E V A T C 20 APPROXIMATE O
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
OVER ALL ( dB )
A
NC-50
38
26
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V (H) 50/60Hz 220-240/220-230V (L)
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
4D048279B
8000
63
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
4D048280B
8000
FTXS25EVMA
70
COOLING
70
OVER ALL ( dB ) 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L)
NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O S d 0 ( D B N A d30 B E V A T C 20 APPROXIMATE O
A
NC-50
37
25
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V (H) 50/60Hz 220-240/220-230V( 220-240/220-230V (L)
Cooling
NC-20
OVER ALL ( dB ) NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O S d 0 ( D B30 N A d B E V A T C 20 APPROXIMATE O
SCALE
50/60Hz 50/60Hz 220-240/220-230V 220-240/220-230V (H) (L)
A
NC-50
37
28
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V( 220-240/220-230V (H) 50/60Hz 220-240/220-230V( 220-240/220-230V (L)
Heating
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
HEATING
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
8000
63
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
3D048277B
8000
FTXS35EVMA
70
COOLING
70
OVER ALL ( dB )
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N d30 A B E V A T C 20 APPROXIMATE O
50/60Hz SCALE 220-240/220-230V (H)
NC-60
A
NC-50
38
26
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V( 220-240/220-230V (H) 50/60Hz 220-240/220-230V( 220-240/220-230V (L)
Cooling
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
50/60Hz 220-240/220-230V (L)
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
Room Air Conditioners E-Series
HEATING OVER ALL ( dB )
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O S d 0 ( D B30 N A d B E V A T C 20 APPROXIMATE O
50/60Hz SCALE 220-240/220-230V (H)
NC-60
A
NC-50
50/60Hz 220-240/220-230V (L)
38
29
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220-240/220-230V 50/60Hz
JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE
NC-30
50/60Hz 220-240/220-230V( 220-240/220-230V (H) 50/60Hz 220-240/220-230V( 220-240/220-230V (L)
Heating
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
8000
63
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
8000
3D048278B
25
Sound Level
ED04-805
10.2 10.2.2 .2 Ou Outd tdoo oorr Units Units RKS25EBVMA
RKS35EBVMA
70
OVER ALL ( dB ) NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N A d30 B E V A T C 20 APPROXIMATE O
NC-50
SCALE
50/60Hz 220~240V( 220~240V (H)
A
46
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
70
OVER ALL ( dB ) NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N 30 A d B E V A T C 20 APPROXIMATE O
NC-50
SCALE
50/60Hz 220~240V (H)
A
47
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
4D047727G
8000
63
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
4D047728G
8000
RXS25EBVMA
70
COOLING OVER ALL ( dB )
L E 60 V E L E R ) U r 50 S a S b E µ R 2 0 P 0 D 0 . 40 N 0 U = B O d S 0 ( D B N d30 A B E V A T C 20 APPROXIMATE O
NC-60
NC-50
SCALE
50/60Hz 220~240V(H)
A
46
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
Cooling NC-20
HEATING OVER ALL ( dB ) NC-60
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O S d 0 ( D B30 N A d B E V A T 20 C APPROXIMATE O
NC-50
SCALE
50/60Hz 220~240V(H)
A
47
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
Heating NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
70
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
63
8000
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
3D047725H
8000
RXS35EBVMA
70
COOLING OVER ALL ( dB )
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B N d30 A B E V A T C 20 APPROXIMATE O
NC-60
NC-50
26
50/60Hz 220~240V(H)
A
47
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
Cooling NC-20
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
HEATING OVER ALL ( dB )
L E 60 V E L E R ) U r 50 S a S b E µ R 2 P 0 0 D 0 . 40 N 0 U = B O d S 0 ( D B30 N A d B E V A T C 20 APPROXIMATE O
NC-60
NC-50
SCALE
50/60Hz 220~240V(H)
A
48
( B.G.N IS ALREADY RECTIFIED ) OPERATING CONDITIONS NC-40
POWER SOURCE
220~240V 50/60Hz
JIS STANDARD NC-30
Heating NC-20
THRESHOLD HEARING FOR CONTINUOUS NOISE
THRESHOLD HEARING FOR CONTINUOUS NOISE
63
SCALE
70
8000
63
125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) Hz)
8000
3D047726H
Room Air Conditioners E-Series
ED04-805
Electric Characteristics
11.Electric Characteristics Representative Unit Combination Indoor Unit
FTKS25EVMA
FTKS35EVMA
FTXS25EVMA
FTXS35EVMA
Outdoor Unit
RKS25EBVMA
RKS35EBVMA
RXS25EBVMA
RXS35EBVMA
Power Supply Hz-Volts
Voltage Range
50 - 220 50 - 230 50 - 240
MAX.50Hz 264V MIN.50Hz 198V
60 - 220 60 - 230
MAX.60Hz 253V MIN.60Hz 198V
50 - 220 50 - 230 50 - 240
MAX.50Hz 264V MIN.50Hz 198V
60 - 220 60 - 230
MAX.60Hz 253V MIN.60Hz 198V
50 - 220 50 - 230 50 - 240
MAX.50Hz 264V MIN.50Hz 198V
COMP MCA
MFA
RHz
R LA
OFM
IFM
W
FLA
W
FLA
23
0.22
40
0.14
23
0.22
40
0.14
23
0.22
40
0.14
23
0.22
40
0.14
3.5 3.3 9.75
10
48.5
3.2 3.5 3.3 4.4 4.2
9.75
10
75.0
4.0 4.4 4.2 3.5 3.3
9.75
60 - 220 60 - 230
MAX.60Hz 253V MIN.60Hz 198V
50 - 220 50 - 230 50 - 240
MAX.50Hz 264V MIN.50Hz 198V
60 - 220 60 - 230
MAX.60Hz 253V MIN.60Hz 198V
10
48.5
3.2 3.5 3.3 4.4 4.2
9.75
10
75.0
4.0 4.4 4.2
SYMBOLS:
NOTE:
MCA
: MIN. CIRCUIT AMPS (A)
MFA MFA
: MAX. MAX. FUSE FUSE AMPS AMPS (A) (A)
RLA RLA
: RA RATED LO LOAD AMP AMPS S (A) (A)
OFM OFM
: OUT OUTDO DOOR OR FAN MOTO MOTOR R
IFM
: INDOOR FA FAN MOTOR
FLA
: FULL LOA LOAD AMPS MPS (A) (A)
W
: FAN MOTOR RATED OUTPUT (W)
RHz RHz
: RATE RATED D OPER OPERAT ATIN ING G FRE FREQU QUEN ENCY CY (Hz (Hz))
1. RL R LA is based on the following conditions. Indoor temp. 27°CDB/19°CWB 27°CDB/19°CWB Outdoor temp. 35°CDB. 2. Maximum allowable allowable voltage variation variation between phases is is 2%. 3. Select wire size based on the larger value of MCA. MCA. 4. Instead of fuse, use circuit breaker. breaker. 5. Be sure to install an earth leak detector. detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be used an earth leak detector capable handling high harmonics in order to prevent malfunctioning of the earth leak detector itself.) 3D049968D 3D049969D
Room Air Conditioners E-Series
27
Installation Manual
ED04-805
12.Installation Manual 12.1 Indoor Units
Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety. WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual: Be sure to observe this instruction.
Be sure to establish an earth connection.
Never attempt.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use and cleaning of the unit according to the Operation Manual.
WARNING should be left to the dealer or another professional. Improper installation may cause water leakage, electrical shock, or fire. • Installation should • Install the air conditioner according to the instructions given in this m anual. Incomplete installation may cause water leakage, electrical shock, or fire. • Be sure to use the supp lied or specified installation parts. Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire. • Install the air conditioner on a solid base that can support the weight of the unit. An inadequate base or incomplete installation may cause injury in the event the unit falls off the base. • Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice. Insufficient capacity or incomplete electrical work may cause electrical shock or fire. • Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. • For wiring, use a cable length enough to cover the entire distance with no connection. Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit. (Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels. Install covers over the wires. Incomplete cover installation may cause terminal overheating, electri cal shock, or fire. • When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified refrigerant (R410A), such as air. (Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.) • The installation height from the floor must be over 1.8m. • If any refrigerant has leaked out during the installation work, ventilate the room. (The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out. (The refrigerant produces a toxic gas if exposed to flames.)
• During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the shut-off valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor. If the compressor is not attached and the shut-off valve is open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone telephone earth. Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage damage to the air conditioner.
• Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION • Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage. If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual. Inadequate piping may cause flooding. • Note for installing the outdoor unit. (For heat pump model only.) In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor unit’s drain may freeze. If so, it is recommended to install an electric heater in order to protect drain from freezing.
• Tighten the flare nut according to the specified method such as with a torque wrench. If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
28
Room Air Conditioners E-Series
ED04-805
Installation Manual
Accessories A Mounting plate
Mounting plate fixing screws M4 × 25L Titanium Apatite Photocatalytic C Air-Purifying Filter B
D Wireless remote controller
1
E Remote controller holder
6
F
2
G AAA dry-cell batteries
1
H
Fixing screws for remote controller holder M3 × 20L
Indoor unit fixing screws M4 × 12L
1
J
Insulation tape
1
2
K Operation manual
1
2
L Installation manual
1
2
Choosing an Installation Site • Before choosing the installation site, obtain user approval.
1.
2.
Indoor unit. • 1) 2) 3) 4) 5) 6) 7) 8) 9)
The indoor indoor unit should should be sited in a place place where where:: the restrictions on installation installation specified in the indoor unit installation drawings are met, both air intake intake and exhaust exhaust have clear clear paths met, the unit is not not in the path of direct direct sunlight sunlight,, the unit is away away from the source source of heat heat or steam, steam, there is no source of machine oil vapour vapour (this may shorten indoor unit life), life), cool (warm) (warm) air is circulated circulated throughout throughout the room, room, the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range, the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound), install install at the recommended recommended height height (1.8m). (1.8m).
Wireless remote controller. 1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller controller signals are properly received by the indoor unit (within 7 metres).
Installation Tips
1. Removing and installing front panel.
• Removal method
Hook fingers on the panel protrusions on the left and right of the main body, and open until the panel stops. Slide the front panel sideways to disengage the rotating shaft. Then pull the front panel toward you to remove it.
Place both hands under the center of the front grille, and while pushing up, pull it toward you.
2) Pull toward you.
3. How to set set the different addresses.
Push the rotating shaft of the front panel into the groove.
2. Removing and installing front grille.
• Removal method
1) Push up.
Be sure to wear protection gloves.
• Installation method 1) Install the front grille and firmly engage the upper hooks (3 locations). 2) Install 2screws of the the front grille. 3) Install the air filter and then mount the front panel.
• Installation method Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the center of the lower surface of the panel firmly to engage the tabs.
CAUTION
mark area (3 locations)
Upper hook
1)Remove front panel to remove the air filter. 2)Remove the front grille. 3)In front of the mark of the front grille, there are 3 upper hooks. Lightly pull the front grille Lightly pull the front toward you with one hand, and grille toward you with one hand, and push push down on the hooks with down on the hooks with the fingers of your other the fingers of your other hand. hand. (3 locations)
Push down.
Upper hook
Upper hook
When two indoor units are installed in one room, the two wireless remote controllers can be set for different addresses. 1) In the same way as when connecting to an HA system, remove the metal plate electrical wiring cover. 2) Cut the address jumper (JA) on the printed circuit board. 3) Cut the address jumper (J4) in the remote controller.
S S E R D D A
A J
JA ADDRESS EXIST CUT
1 2
J4
J4 ADDRESS EXIST CUT
Room Air Conditioners E-Series
1 2
29
Installation Manual
ED04-805
Indoor Unit Installation Drawings How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front grille. How to remove the indoor unit. Push up the marked area (at the lower part of the front grille) to release the claws. If it is difficult t o Front grille release, remove the front grille.
A Mounting plate
A Mounting plate
Clip
Bottom frame
Mark (rear side)
The mounting plate should be installed on a wall which can support the weight of the indoor unit. B Mounting plate fixing screws M4 × 25L (6)
Caulk pipe hole gap with putty.
30mm or more from ceiling
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.
Front panel Wrap the insulation pipe with the finishing tape from bottom to top.
50mm or more from walls (on both sides)
Intelligent-eye sensor
M4 × 16L
Air filters
Service lid Opening service lid Service lid is opening/closing type. Opening method 1) Remove the service lid screws. 2) Pull out the service lid diagonally down in the direction of the arrow. 3) Pull down.
C Titanium Apatite Photocatalytic Air-Purifying Filter (2) C Titanium Apatite Photocatalytic Air-Purifying Filter
Air filter Filter frame D Wireless remote controller
Tab F Fixing screws for remote controller holder M3 × 20L (2)
Before screwing the remote controller holder to the wall, make sure that control signals are properly received by indoor unit. E Remote controller holder
Intelligent-eye Sensor CAUTION 1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction. 2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.
30
Room Air Conditioners E-Series
ED04-805
Installation Manual
Indoor Unit Installation (1) 1.
Installing the mounting plate. • The mounting mounting plate plate should should be installed installed on a wall which which can support support the the weight of the the indoor indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure Secure the mounting mounting plate to the wall with with screws.
Recommended mounting plate retention spots and dimensions 450
Recommended mounting plate retention spots (6 spots in all)
100 Place a leveler on raised tab.
80
5 . 1 4 1
(Bolt size : M10)
5 . 0 5
400
(Bolt size : M10)
135 5 . 6 4
5 . 7 4
3 8 2
Use tape measure as shown. Position the end of a tape measure at ∇.
7 5 . 8 1 3 1 5 .
0 1 1 φ65
φ65
5 . 4 4
4 4
60
130 22 0
60
110
50 800
Drain hose position
Throughthe-wall hole φ65mm
Liquid pipe end Keep here the piece cut out from the unit for piping Gas pipe end
* The removed pipe port cover can be kept in the mounting plate pocket.
Removed pipe port cover
A Mounting plate
2.
Boring a wall hole and installing wall embedded pipe. • For walls walls containing containing metal metal frame frame or metal metal board, board, be sure to use a wall wall embedded pipe and wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire. • Be sure sure to caulk caulk the gaps gaps around around the pipes pipes with with caulking caulking material material to prevent water leakage. 1) Bore a feed-throu feed-through gh hole of 65mm in the the wall so it has a down slope toward the outside. 2) Insert a wall wall pipe into into the hole. hole. 3) Insert a wall wall cover into into wall pipe. pipe. 4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty.
Room Air Conditioners E-Series
Inside Wall embedded pipe (Field supply)
Outside Caulking
φ65
Wall hole cover (Field supply) Wall embedded pipe (Field supply)
31
Installation Manual
ED04-805
Indoor Unit Installation (2) 3.
Installing indoor unit. 3-1. Right-side, Right-side, right-back, right-back, or right-botto right-bottom m piping. 1) Attach the drain hose to the underside of the refrigerant pipes with an adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with an insulation tape.
Remove pipe port cover here for right-side piping.
Right-back piping Right-bottom piping
Remove pipe port cover here for right-bottom piping.
Bind coolant pipe and drain hose together with insulating tape.
A Mounting plate
3) Pass the drain hose and refrigerant pipes through the wall hole, then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide. 4) Open the front panel, then open the service lid. (Refer to Installation Tips.) 5) Pass the interconnecting wires from the outdoor unit through the feed-through wall hole and then through the back of the indoor unit. Pull them through the front side. Bend the ends of tie wires upward for easier work in advance. (If the interconnecting wire ends are to be stripped first, bundle wire ends with adhesive tape.) 6) Press the bottom frame of the indoor unit with both hands to set it on the mounting plate hooks. Make sure that the wires do not catch on the edge of the indoor unit.
Hang indoor unit’s hook here.
A Mounting plate When stripping the ends of interconnecting interconnecting wires in advance, bind right ends of wires with insulating tape.
Interconnecting wires Wire guide
3-2. Left-side, Left-side, left-back, left-back, or left-bottom left-bottom piping. piping. 1) Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape.
Remove pipe port cover here for leftside piping. Left-side piping Left-back piping
Remove pipe port cover here for left-bottom piping.
Left-bottom piping
2) Be sure to connect the drain hose to the drain port in place of a drain plug.
3) Shape the refrigera refrigerant nt pipe along the pipe path marking on the mounting plate. 4) Pass drain hose hose and refrigerant refrigerant pipes through through the wall hole, then set the indoor unit on Drain hose mounting plate hooks, using the markings at Caulk this hole with putty or the top of indoor unit as a guide. caulking material. 5) Pull in the interconn interconnecting ecting wires. wires. 6) Connect Connect the inter-unit inter-unit piping. piping. 7) Wrap the refrigerant pipes and drain hose together with insulation tape as right figure, in case of setting the drain hose through the back of the indoor unit. 8) While exercising care so that the interconnecting wires do not catch indoor unit, press the bottom edge of indoor unit with both hands until it is firmly caught by the mounting mounting plate hooks. Secure indoor unit to the mounting plate with the screws (M4 × 12L).
3-3. 3-3. Wall Wall embedded embedded piping piping.. Follow the instructions given under Left-side, left-back, or left-bottom piping
1) Insert the the drain hose to this this depth so it won’ won’t be pulled out of the drain pipe.
32
How to set drain plug a p N o g
Do not apply lubricating oil (refrigerant machine oil) when inserting. Application of causes deterioration and drain leakage of the plug. Insert a hexagon wrench (4mm)
A Mounting plate
Bind with plastic tape.
Wrap insulating tape around the bent portion of refrigerant pipe. Overlap at least half the width of the tape with each turn.
Drain hose
A Mounting plate Refrigerant pipes
Bottom frame H M4 × 12L (2 point) point)
Insert drain hose to this depth so it won’t be pulled out of drain pipe.
50mm or more
Outer wall
Inner wall
Drain hose Vinyl chloride drain pipe (VP-30)
Room Air Conditioners E-Series
ED04-805
Installation Manual
Indoor Unit Installation (3) With a multi indoor unit
4.
, install as described in the installation manual supplied with the Multi outdoor unit.
Wiring.
Terminal block
1) Strip wire ends ends (15mm). (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals. 3) Connect the earth wires to the corresponding terminals. Attach the earth wire so that it is not connected to the fan motor connector. 4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer. 5) In case of connecting to an adapter system. Run the remote controller cable and attach the S21. (Refer to 5. When connecting to an HA system.) 6) Shape the wires so that the service lid fits securely, then close service lid.
Electrical component box Shape wires so that the service lid will fit securely. Connector for fan motor Firmly secure wire retainer so that wires sustain no external stress. Wire retainer Use the specified wire type.
Firmly fix the wires with the terminal screws.
Outdoor unit 123
When wire length exceeds 10m, use 2.0mm diameter wires.
Indoor unit
LN
1 2 3
Firmly fix the wires with the terminal screws.
WARNING
H05VV
1) Do not use tapped wires, stranded wires, wires, extensioncords, or starburst connections, as they may may cause overtheating, electrical shock,or fire. 2) Do not use locally purchased electrical electrical parts inside the product. (Do not branch branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire.
5.
When connecting to an HA system. 1) Remove the front front grille. grille. Tab (2 screws) Notched part Push 2) Remove the electrical electrical Slide wiring box. (1 screw) 3) Remove the metal metal plate plate HA connector (S21) electrical wiring cover. (3 tabs) Slide 4) Attach the connection connection 4) Attach the connection cord to Screw cord to the S21 connector 3) Remove the metal Pull the S21 connector and pull the plate electrical Tab harness out through the wiring cover. and pull the harness out notched part in the figure. through the notched part in the figure. 5) Replace the electrical wiring cover as it was, and pull the harness around, as shown in the figure.
6.
HA cord
5) Replace the electrical rical wiring cover as it was, and pull the harness around, as shown in the figure.
Drain piping. 1) Connect Connect the drain hose, hose, as described described below. The drain hose should be inclined downward.
3) When drain hose hose requires extension extension,, obtain an extension hose commercially available. Be sure to thermally insulate the indoor section of the extension hose.
No trap is permitted.
Indoor unit drain hose
Do not put the end of the hose in water.
8 1
Extension drain hose
φ
Heat insulation tube (Field supply)
2) Remove the the air filters filters and pour some water water into the drain pan to check the water flows smoothly.
4) When connecting a rigid polyvinyl chloride pipe (nominal diameter 13mm) directly to the drain hose attached to the indoor unit as with embedded piping work, use any commercially available drain socket (nominal diameter 13mm) as a joint. 8 1
φ
Drain hose supplied with the indoor unit
Room Air Conditioners E-Series
Commercially available drain socket (nominal diameter 13mm)
Commercially available rigid polyvinyl chloride pipe (nominal diameter 13mm)
33
Installation Manual
ED04-805
Refrigerant Piping Work Work With a multi indoor unit
1.
, install as described in the installation manual supplied with the Multi outdoor unit.
Flaring the pipe end. 1) Cut the pipe pipe end with a pipe pipe cutter. cutter. 2) Remove burrs burrs with the cut surface surface facing facing downward so that the chips do not enter the pipe. 3) Put the the flare nut on the the pipe. 4) Flare Flare the the pipe. pipe. 5) Check that the the flaring is properly properly made. made.
(Cut exactly at right angles.)
Remove burrs
Flaring Set exactly at the position shown below. A
Die
Flare tool for R410A
Conventional flare tool
Clutch-type
Clutch-type (Rigid-type) Wing-nut type (Imperial-type)
A
0-0.5mm
1.0-1.5mm
Flare’s inner surface must be flaw-free.
1.5-2.0mm
Check
The pipe end must be evenly flared in a perfect circle. Make sure that the flare nut is fitted.
WARNING 1) 2) 3) 4) 5) 6)
2.
Do not use mineral mineral oil oil on flared flared part. Prevent mineral oil from getting into the system as this would reduce the lifetime of the units. Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. Do never install a drier to this R410A unit in order to guarantee its lifetime. lifetime. The drying material material may dissolve dissolve and damage the system. system. Incomplete Incomplete flaring may cause refrigeran refrigerantt gas leakage.
Refrigerant piping CAUTION
1) Use the flare nut fixed to the main unit. (T (To prevent cracking cracking of the flare nut by aged deterioration.) 2) To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) 3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. [Apply oil]
Do not apply refrigeration oil to the outer surface.
Apply refrigeration oil to the inner surface of the flare.
[Tighten]
Torque wrench
Flare nut tightening torque
Flare nut
Gas side Spanner
Piping union
Do not apply refrigeration oil to the flare
Liquid side
3/8 inch
1/4 inch
32.7-39.9N • m
14.2-17.2N • m
(330-407kgf • cm)
(144-175kgf • cm)
Flare nut
nut avoid tightening with over torque.
2-1. Caution Caution on piping piping handling. handling. 1) Protect Protect the open end of the pipe against dust and moisture. moisture. 2) All pipe bends bends should be as gentle gentle as possible. possible. Use a pipe bender for bending. (Bending radius should be 30 to 40mm or larger.)
Rain
If no flare cap is available, cover the flare mouth with tape to keep dirt or water out.
2-2. Selection Selection of copper and and heat insulation insulation materials. materials. • When using commercial copper pipes and fittings, observe the following: 1) Insulation Insulation material: material: Polyethylene Polyethylene foam Gas pipe Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/(mh • °C)) Refrigerant gas pipe’s surface temperature reaches 110°C max. Choose heat insulation materials that will withstand this temperature. 2) Be sure to insulate insulate both the gas and liquid piping and to provide provide Gas pipe insulation dimensions as below. insulation Gas side 25/35 class O.D. 9.5mm
Liquid side O.D. 6.4mm
Thickness 0.8mm
Gas pipe thermal insulation
Wall
Be sure to place a cap.
25/35 class
Liquid pipe thermal insulation
I.D. 12-15mm
I.D. 8-10mm
Inter-unit wiring
Finishing tape
Liquid pipe
Liquid pipe insulation Drain hose
Thickness 10mm Min.
3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.
34
Room Air Conditioners E-Series
ED04-805
Installation Manual
Trial Operation Opera tion and Testing 1.
Trial operation and testing. 1-1 Measure Measure the supply voltage voltage and make sure that it falls in the specified specified range. 1-2 Trial operation operation should should be carried out in either cooling cooling or heating heating mode.
For Heat pump
• In cooling mode, select t he lowest programmable temperature; in heating mode, select the highest programmable temperature. 1) Trial operation may be disabled in either mode depending on the room temperature. temperature. Use the remote controller for t rial operation as described below. 2) After trial operation is complete, set the temperature temperature to a normal normal level (26˚C to 28˚C in cooling mode, 20˚C to 24˚C in heating mode). 3) For protection, the system disables restart operation operation for 3 minutes minutes after it is turned off.
For Cooling only
• Select the lowest programmable temperature. 1) Trial operation in cooli cooling ng mode may be disabled depending depending on the room temperature. temperature. Use the remote controller for t rial operation as described below. 2) After trial operation is complete, set the temperature temperature to a normal normal level (26˚C to 28˚C). 3) For protection, the system disables restart operation operation for 3 minutes minutes after it is turned off.
1-3 Carry out the test operation in accordance with the operation manual to ensure that all functions and parts, such as louver movement, are working properly. requires a small amount of power in its standby mode. mode. If the system is not to be used for • The air conditioner requires some time after installation, shut off the circuit breaker t o eliminate unnecessary power consumption.
• If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when the circuit breaker is opened again.
Trial operation from remote controller. 1) Press ON/OFF ON/OFF button button to turn turn on the system. system. 2) Simultaneousl Simultaneously y press centre of TEMP TEMP button and MODE button. button. 3) Press MODE button twice. (“ ” will appear on the display to indicate that Trial Operation mode is selected.) 4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press ON/OFF button.
2.
Test items. Test items
Symptom (diagnostic display on RC)
Indoor and outdoor units are installed properly on solid bases.
Fall, vibration, noise
No refrigerant gas leaks.
Incomplete cooling/heating function
Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated.
Water leakage
Draining line is properly installed.
Water leakage
System is properly earthed.
Electrical leakage
The specified wires are used for interconnecting wire connections.
Inoperative or burn damage
Indoor or outdoor unit’s air intake or exhaust has clear path of air. Shut-off valves are opened.
Incomplete cooling/heating function
Indoor unit properly receives remote controller commands.
Inoperative
Check
3P175978-5D
Room Air Conditioners E-Series
35
Installation Manual
ED04-805
12.2 Outdo tdoor Units its
Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety. WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual: Be sure to observe this instruction.
Be sure to establish an earth connection.
Never attem pt.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use and cleaning of the unit according to the Operation Manual.
WARNING • Installation should be left to the dealer or another professional. Improper installation may cause water leakage, electrical shock, or fire. installation may cause water leakage, electrical shock, or fire. • Install the air conditioner according to the instructions given in this manual. Incomplete installation • Be sure to use the supplied or specified installation parts. Use of other parts may cau se the unit to come to lose, water leakage, electrical shock, or fire. • Install the air conditioner on a solid base that can support the weight of the unit. An inadequate base or incomplete installation may cause injury in the event the unit falls off the base. • Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice. Insufficient capacity or incomplete electrical work may cause electrical shock or fire. • Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. • For wiring, use a cable length enough to cover the entire distance with no connection. Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit. (Failure to do so may cause abnormal heat, electric shock or fire.) • Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete Incomplete connections or clamping may cause terminal overheating overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels. Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire. • When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified refrigerant (R410A), such as air. (Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.) • If any refrigerant has leaked out during the installation work, ventilate the room. (The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out. (The refrigerant produces a toxic gas if exposed to flames.)
• During pump-down, stop the compressor b efore removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor. If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth. Incomplete earth may cause electrical electric al shock, or fire.
A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION • Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage. If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual. Inadequate piping may cause flooding. • Tighten the flare nut according to the specified method such as with a torque wrench. If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
36
Room Air Conditioners E-Series
ED04-805
Installation Manual
Accessories Accessories supplied with the outdoor unit: (B) Drain plug (Heat pump-Models) (A) Installation manual
1
1 There is on the bottom packing case.
Precautions for Selecting the Location 1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified. 2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbors of the user. 3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble. 4) There must be sufficient spaces for carrying the unit into and out of the site. 5) There must be sufficient space for air passage and no obstructions around around the air inlet and the air outlet. 6) The site must be free from the possibility of flammable gas leakage in a nearby place. 7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent interference interferenc e to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio wave conditions.) 8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner. conditioner. 9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE Cannot be installed hanging from ceiling or stacked.
CAUTION When operating the air conditioner in a low outdoor ambient temperature, be sure to follow the instructions described below. 1) To prevent exposure exposure to wind, install install the outdoor unit with with its suction side facing the wall. 2) Never install the the outdoor unit at a site where where the suction side may be exposed directly to wind. 3) To prevent exposure exposure to wind, it is recommended recommended to install install a baffle plate on the air discharge side of the outdoor unit. 4) In heavy snowfall areas, areas, select an installation site where the snow will not affect the unit.
Construct a large canopy. Construct a pedestal.
Install the unit high enough off the ground to prevent burying in snow.
Precautions on Installation • Check the strength strength and level of the installation installation ground so so that the unit will not cause cause any operating vibration vibration or noise after installed. • In accordance with with the foundation drawing, drawing, fix the unit securely securely by means means of the foundation bolts. bolts. (Prepare four sets of M8 or M10 foundation bolts, nuts and washers each which are available on the market.) • It is best best to screw screw in the foundation bolts until their length are 20mm from the foundation surface. 0 2
Room Air Conditioners E-Series
37
Installation Manual
ED04-805
Outdoor Unit Installation Drawings Wrap the insulation pipe with the finishing tape from bottom to top. 20m 15m
Max. allowable length Max. allowable height Additional refrigerant required for refrigerant pipe exceeding 10m in length.
20g/m
Gas pipe Liquid pipe
O.D. 9.5mm O.D. 6.4mm * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. ** When connecting the FVXS indoor unit, the shortest piping length should be no less than around 2.5m.
Stop valve cover How to remove the stop valve cover. Remove the screw on the stop valve cover. Slide the lid downward to remove it.
2 5 50 mm f r 0 ro m o w al l l
How to attach the stop valve cover.
Insert the upper part of the stop valve cover into the outdoor unit to install. Tighten the screws.
e l o 1 h 1 t 3 l o b s t e o r o t F n e c
In sites with poor drainage, use block bases for outdoor unit. Adjust foot height until the unit is leveled. Otherwise, water water leakage or pooling of water may occur.
5 7 74 4 ( F Fo o o o t t b o o l l t t- - h h o o l le e c e e n n t tr r e es s )
Allow space for piping and electrical servicing.
10 5 5. 5
( F Fr r o om u m n ni i t t’ ’ s s s i i d de ) e
Where there is a danger of the unit falling, use foot bolts, or wires. Unit: mm
Installation Guidelines • Where a wall or other other obstacle is in the path of of outdoor unit’s intake intake or exhaust airflow, airflow, follow the installation guidelines below. • For any of the below installation installation patterns, patterns, the wall height height on the exhaust side should should be 1200mm or or less. Wall facing one side More than 50
Walls facing two sides More than 100
More than 50 More than 50
Side view
More than 150
More than 150 More than 100
1200 or less
38
Walls facing three sides
More than 50 Top vi ew
More than 300 Top view Unit: mm
Room Air Conditioners E-Series
ED04-805
Installation Manual
Outdoor Unit Installation (1) 1.
Installing outdoor unit. 1) When installing the outdoor unit, refer to “Precautions “Precautions for Selecting the Location” and the “Outdoor Unit Installation Drawings”. 2) If drain work is necessary, necessary, follow the procedures procedures below. below.
2.
Drain work (Heat pump-models). 1) Use drain drain plug for drainage. 2) If the drain port is covered covered by a mounting mounting base or floor surface, surface, place place additional foot bases of at least 30mm in height under the outdoor unit’s feet. 3) In cold areas, do not not use a drain hose with with the outdoor unit. unit. (Otherwise, drain water may freeze, impairing heating performance.)
3.
Drain-water hole Bottom frame Drain plug Hose (available commercially, inner dia. 16mm)
Flaring the pipe end. (Cut exactly at right an angles.)
1) Cut the pipe end with a pipe pipe cutter. cutter. 2) Remove Remove burrs with with the cut surface surface facing downward so that the chips do not enter the pipe. 3) Put the flare flare nut nut on the pipe. pipe. 4) Flare Flare the the pipe. pipe. 5) Check that the flaring flaring is properly properly made. made.
Remove bu burrs
Flaring Set exactly at the position shown below. A
Flare tool for R410A Clutch-type
Die
A
Conventional flare tool Clutch-type (Rigid-type) Wing-nut type (Imperial-type)
0-0.5mm
1.0-1.5mm
Flare’s inner surface must be flaw-free.
1.5-2.0mm
Check
The pipe end must be evenly flared in a perfect circle. Make sure that the flare nut is fitted.
WARNING 1) Do not use mineral oil on flared part. 2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units. 3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. 4) Do never install a drier to this R410A unit in order to guarantee its lifetime. 5) The drying material may dissolve and damage the system. 6) Incomplete flaring may cause refrigerant gas leakage.
4.
Refrigerant piping. CAUTION
1) Use the flare nut fixed to the main unit. (To (To prevent cracking cracking of the flare nut by aged deterioration.) deterioration.) 2) To prevent prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) 3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centres of both flares and tighten the flare flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. [Apply oil] Do not apply refrigeration oil to the outer surface.
[Tighten] Apply refrigeration oil to the
Torque wrench
inner surface of the flare.
Flare nut Spanner
Piping union
Do not apply refrigeration oil to the flare
Flare nut
nut avoid tightening with over torque.
Flare nut tightening torque Gas side Liquid side 3/8 inch 1/4 inch 32.7-39.9N • m 14.2-17.2N • m (330-407kgf • cm) (144-175kgf • cm)
Valve cap tightening torque Gas side Liquid side 3/8 inch 1/4 inch 21.6-27.4N • m 21.6-27.4N • m (220-280kgf • cm) (220-280kgf • cm) Service port cap tightening torque
Room Air Conditioners E-Series
10.8-14.7N • m (110-150kgf • cm)
39
Installation Manual
ED04-805
Outdoor Unit Installation (2) 5.
Purging air and checking gas leakage. • When piping work is completed, it is necessary to purge the air and check for gas leakage.
WARNING 1) Do not mix any substance other than the specified specified refrigerant (R410A) (R410A) into the refrigeration cycle. cycle. 2) When refrigerant refrigerant gas leaks occur, ventilate the room as soon and as much as possible. possible. 3) R410 R410A A, as well as other refrigerants, should always be recovered and never be released directly into the environment. 4) Use a vacuum pump for R410A exclusively. exclusively. Using the same vacuum vacuum pump for different refrigerants refrigerants may damage the vacuum pump or the unit. • If using additional refrigerant, perform air purging from the refrigerant
pipes and indoor unit using a vacuum pump, then charge additional refrigerant. • Use a hexagonal wrench (4mm) to operate the stop valve rod. • All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
Pressure Compound pressure gauge meter Gauge manifold
Low-pressure valve
Highpressure valve
Valve caps
Liquid stop valve
Charging hoses Vacuum pump Service port Gas stop valve
1) Connect projection side of charging charging hose (which comes from gauge gauge manifold) to gas stop valve’s service port.
2) Fully open gauge manifold’s low-pressure valve (Lo) and completely close its high-pressure valve (Hi). (High-pressure valve subsequently requires no operation.)
3) Do vacuum vacuum pumping pumping and make sure sure that the compoun compound d pressure gauge gauge reads reads – 0.1MPa 0.1MPa (– 76cmHg)*1. 76cmHg)*1.
4) Close gauge gauge manifold’s manifold’s low-pressure low-pressure valve (Lo) and stop vacuum pump. pump. (Keep this state for a few minutes to make sure that the compound pressure gauge pointer does not swing back.)*2.
5) Remove Remove covers from from liquid stop stop valve and gas gas stop valve. valve.
6) Turn the liquid stop valve’s rod 90 degrees counterclockwise with a hexagonal hexagonal wrench to open valve. Close it after 5 seconds, and check for gas leakage. Using soapy water, check for gas leakage from indoor unit’s flare and outdoor unit’s flare and valve rods. After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas stop valve’s service port, then fully open liquid and gas stop valves. (Do not attempt to turn valve rod beyond its stop.)
8) Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified torques.
*1. Pipe length vs. vacuum pump run time Pipe length
Up to 15 metres
More than 15 metres
Run time
Not less than 10 min.
Not less than 15 min.
*2. If the compound pressure gauge pointer swings back, refrigerant may have water content or a loose pipe joint may exists. Check all pipe joints and retighten retighten nuts as needed, then repeat steps 2) through through 4).
40
Room Air Conditioners E-Series
ED04-805
Installation Manual
Outdoor Unit Installation (3) 6.
Refilling the refrigerant.
Filling a cylinder with an
Filling other cylinders
Check the type of refrigerant to be used on the machine attached siphon Turn the cylinder Stand the cylinder upright when filling. nameplate. upside-down when There is a siphon pipe inside, filling. Precautions when adding R410A so the cylinder need not be Fill from the liquid pipe in liquid form. upside-down upside-down to fill with liquid. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation. 1) Before filling, check whether the cylinder has a siphon attached or not. (It should have something like “liquid filling siphon attached” displayed on it.) • Be sure to use the R410A tools to ensure pressure and to prevent prevent foreign objects entering.
7.
Refrigerant piping work.
7-1 Cautio Cautions ns on pipe pipe hand handlin ling. g. 1) Protect the open end of the pipe against dust and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. (Bending radius should be 30 to 40mm or larger.)
Rain
If no flare cap is available, cover the flare mouth with tape to keep dirt or water out.
Selection of copper and heat insulation materials.
7-2
When using commercial copper pipes and fittings, observe the following: 1) Insulation Insulation material: material: Polyeth Polyethylene ylene foam foam Heat transfer transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/(mh •˚C)) Refrigerant gas pipe’s surface temperature reaches 110˚C max. Choose heat insulation materials that will withstand this temperature. 2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below. below. Gas side
Liquid side
Gas pipe thermal insulation
Liquid pipe thermal insulation
O.D. 9.5mm
O.D. 6.4mm
I.D. 12-15mm
I.D. 8-10mm
Thickness 0.8mm
Wall
Be sure to place a cap.
Inter-unit wiring Gas pipe
Liquid pipe
Gas pipe insulation
Thickness 10mm Min.
Liquid pipe insulation Finishing tape
Drain hose
3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.
Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve valve cap from liquid stop valve and gas gas stop valve. Liquid stop 2) Carry out forced cooling cooling operation. operation. valve 3) After five to ten minutes, close the liquid stop valve valve with a hexagonal wrench. wrench. 4) After two to three minutes, close the gas stop valve and stop forced cooling operation.
Hexagonal wrench Close
Gas stop valve Valve cap
How to force cooling operation mode
Using the indoor unit operation/stop button Press the indoor unit operation/stop button for at least five seconds. (Operation will start.) • Forced cooling operation will stop automatically after around 15 minutes. To force a test run to stop, press the indoor unit operation/stop button. Using the main unit’s remote controller 1) Press the “operation/stop” button. (Operation will start.) 2) Press the temperature button and the “operation select” button at the same time. 3) Press the “operation select” button twice. ( will be displayed and the unit will enter test run mode.) 4) Press the “operation select” button to return the operation mode to cooling. • Test run mode will stop automatically after around 30 minutes. To force a test run to stop, press the operation/stop button.
CAUTION 1) When pressing the switch, do not touch the terminal block. It has a high voltage, so doing so may cause electric shock. 2) After closing the liquid stop valve, close the gas stop valve within three minutes, then stop the forced operation.
Room Air Conditioners E-Series
41
Installation Manual
ED04-805
Wiring WARNING 1) Do not use tapped wires, stranded wires, extensioncords, extensioncords, or starburst connections, as they may cause overheating, overheating, electrical shock, or fire. 2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire. 3) Be sure to install an earth leakage breaker. (One that can handle higher harmonics.) harmonics.) (This unit uses an inverter, which means that it must be used an earth leakage breaker capable handling harmonics in order to prevent malfunctioning of the earth leakage breaker itself.) 4) Use an all-pole disconnection type breaker with at least 3mm between the contact point gaps. • Do not turn ON the safety breaker until all work is completed. completed. Firmly fix the wires with 1) Strip the insulation from the wire (20mm). the terminal screws. 2) Connect the connection wires between the indoor and outdoor units so that the terminal numbers match. Tighten the terminal screws securely. We recommend a flathead screwdriver be used to tighten the screws.
Outdoor unit 1 23
When wire length exceeds 10m, use 2.0mm diameter wires.
Indoor unit
Use 2.0mm diameter wires.
1 2 3
Safety breaker Firmly fix the wires with the terminal screws.
1
2
3
LN
1
2
Earth leakage circuit breaker
H05VV
Power supply 50Hz 220V-240V 60Hz 220V-230V Safety breaker RX(K)S 10A RYN RXG 15A
Earth
Power supply terminal block
3
Shape wires so that the service lid and stop valve cover fit securely.
Use the specified wire type and connect it secu rely. rely.
Firmly secure wire retainer so wire terminations will not receive external stress.
Observe the notes mentioned below when wiring to the power supply terminal board. Round crimp-style Precautions to be taken for power supply wiring. Use a round crimp-style terminal for connection to the power terminal supply terminal board. board. In case it cannot be used used due to unavoidable reasons, reasons, be sure to observe the following instruction.
Stranded Wire
CAUTION When connecting the connection wires to the terminal board using a single core wire, be sure to perform curling. Problems with the work may cause heat and fires.
Strip wire end to this point.
Good
Excessive strip length may cause electrical shock or leakage.
Wrong
Stripping wire at terminal block
3) Pull the wire and make sure that it does not disconnect. Then fix the wire in place with a wire stop.
42
Room Air Conditioners E-Series
ED04-805
Installation Manual
Test Run and Final Check 1.
Trial operation and testing. 1-1 Measure the supply supply voltage and make make sure that it falls in the specified specified range. range. 1-2 Trial operation should should be carried out out in eitr cooling or heating heating mode.
For heat pump
• In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature. 1) Trial operation may be disabled in either mode depending on the room temperature. 2) After trial operation is complete, set the temperature to a normal level (26˚C to 28˚C in cooling mode, 20˚C to 24˚C in heating mode). 3) For protection, the unit disables restart operation for 3 minutes after it is turned off.
For cooling only • Select the lowest programmable temperature. 1) Trial operation in cooling mode may be disabled depending on the room temperature. temperature. 2) After trial operation is complete, set the temperature to to a normal level (26˚C to 28˚C). 3) For protection, the unit disables restart operation for 3 minutes after it is turned off.
1-3 Carry out the test operation operation in accordance accordance with the operation operation manual to ensure ensure that all functions functions and parts, such as louver movement, are working properly. • The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for
some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption. • If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when the circuit breaker is opened again.
2.
Test items. Test items
Symptom (diagnostic display on RC)
Indoor and outdoor units are installed properly on solid bases.
Fall, vibration, noise
No refrigerant gas leaks.
Incomplete cooling/heating function
Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated.
Water leakage
Draining line is properly installed.
Water leakage
System is properly earthed.
Electrical leakage
The specified wires are used for interconnecting wire connections.
Inoperative or burn damage
Indoor or outdoor unit’s air intake or exhaust has clear path of air. Stop valves are opened.
Incomplete cooling/heating function
Indoor unit properly receives remote controller commands.
Inoperative
Check
3P208365-6A
Room Air Conditioners E-Series
43
Operation Manual
ED04-805
13.Opera 13. Operation tion Manual
Safety precautions • • • •
Keep this manual where the operator can easily find them. Read this this manual manual attentively attentively before before starting starting up the unit. unit. For safety safety reason the the operator operator must read the following following cautions cautions carefully carefully.. This manual manual classifies classifies precaution precautions s into WARNING WARNING and CAUTION. Be sure sure to follow all precautions precautions below: they are all important for ensuring safety.
WARNING
CAUTION
If you do not follow these instructions exactly, the unit may If you do not follow these instructions exactly, the unit may cause minor or moderate property damage or personal injury. cause property damage, personal injury or loss of life.
Never do.
Be sure to follow the instructions.
Be sure to earth the air conditioner.
Never cause the air conditioner (including the remote controller) to get wet.
Never touch the air conditioner (including the remote controller) with a wet hand.
WARNING • In order to avoid fire, explosion or injury, injury, do not operate the unit when harmful, among which flammable or corrosive gases, are detected near the unit. • It is not good for health to expose your body to the air flow for a long time. • Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range. properly, the refrigerant may be leaking, so call your dealer. • If the air conditioner is not cooling (heating) properly, When carrying out repairs accompanying adding refrigerant, check the content of the repairs with ou r service staff. • Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or fire. For installation, consult the dealer or a qualified technician. • In order to avoid electric shock, fire or injury, injury, if you detect any abnormally such as smell of fire, stop the operation and turn off the breaker. And call your dealer for instructions. • Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may result in electric shocks or fire.
CAUTION • The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line. • In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, instruments, food, plants, animals or works of art. • Never expose little children, plants or animals directly to the air flow. • Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.
2
44
Room Air Conditioners E-Series
ED04-805
Operation Manual
• Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble. • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. conditions, • Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip. • After a long use, check the unit stand and fittings for damage. • Do not touch the air inlet and aluminum fins of outdoor unit. It may cause injury. • The appliance is not intended for use by young children or infirm persons without supervision. • Young children shuld be supervised to ensure that they do not play with the appliance. • To avoid oxygen deficiency, deficiency, ventilate the room sufficiently if equipment with burner is used together with the air conditioner. • Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord. • Do not connect the air conditioner to a power supply different from the one as specified. It may cause trouble or fire. • Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the building, furniture etc. • Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts. • Do not operate the air conditioner with wet hands.
• Do not wash the indoor unit with excessive water, only use a slightly wet cloth. • Do not place things such as vessels containing water or anything else on top of the unit. Water may penetrate into the unit and degrade electrical insulations, resulting in an electric shock.
Installation site. To install the air conditioner in the following types of environments, consult the dealer. • Places with an oily ambient or where steam or soot occurs. • Salty environment such as coastal areas. • Places where sulfide gas occurs such as hot springs. • Places where snow may block the outdoor unit. The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises.
For installation, choose a place as described below. • A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration. • A place from where where the air discharg discharged ed from the outdoor outdoor unit unit or the operation operation noise noise will not annoy your neighbours .
Electrical work. • For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation. • Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for moving or remodeling
3
Room Air Conditioners E-Series
45
Operation Manual
ED04-805
Names of parts
Indoor Unit 1
2
3
4
5 7
11
10
9
6
8 16
14 13
15 12
4
46
Room Air Conditioners E-Series
ED04-805
Operation Manual
Outdoor Unit 17
22 19 20
18
21
Indoor Unit 1. Ai Airr filte filterr
2. Titanium Titanium Apatite Photocataly Photocatalytic tic Air-Purifying Filter: • These filters are attached to the inside of the air
12. Indoor Indoor Unit ON/OFF ON/OFF switch: switch: (page 10.) • Push this switch once to start operation. Push once again to stop it. • The operation mode refers to the following table.
filters.
3. Air inl inlet et 4. Fro Front nt pane panell 5. Pan Panel el tab 6. Room temperat temperature ure sensor: sensor: • It senses the air temperature around the unit. 7. INTELLIG INTELLIGENT ENT EYE sensor: sensor: • It detects the movements of people and automatically switches between normal operation and energy saving operation. (page 18.)
8. Di Disp spla lay y 9. Air out outlet let 10. Flaps (horizon (horizontal tal blades): blades): (page 12.) 11.. Louvr 11 Louvres es (vertical blades): blades): • The louvr louvres es are insid inside e of the air air outlet. outlet. (page 13.)
Temperature setting COOL 22°C AUTO 25°C Mode
FTK FTX
Air flow rate AUTO AUTO
• This switch is useful when the remote controller is missing. 13. Opera Operation tion lamp lamp (green) (green) 14. TIME TIMER R lamp (Yellow (Yellow): ): (page 20.) 15. INTELLIGENT EYE lamp (green): (page 18.)
16. Signal Signal receiv receiver: er: • It receives signals from fr om the remote controller. • When the unit receives a signal, you will hear a short beep. • Operation start .............beep-beep • Settings changed..........beep • Operation stop stop.............. .............. beeee beeeeep ep
Outdoor Unit 17. Air inle inlet: t: (Back and side) 18. Air outl outlet et 19. Refrigerant piping piping and and inter-unit inter-unit cable 20. Dra Drain in hose hose
21. Earth termi terminal: nal: • It is is insid inside e of thi this s cover cover.. 22. Outside Outside air temperature temperature sensor: sensor: • It senses the ambient temperature around the unit.
Appearance of the outdoor unit may differ from some models.
5
Room Air Conditioners E-Series
47
Operation Manual
ED04-805
Remote Controller 1
2
5
ECONO
ON/OFF
3
TEMP
POWERFUL
6
4 7 8 13
MODE QUIET
FAN
SWING
MOLD PROOF
SENSOR
CANCEL
ON
9 10 12 11 16
OFF TIMER
18 17
15 14
1. Signal Signal transmit transmitter: ter: • It sends signals to the indoor unit. 2. Dis Displa play: y: • It displa displays ys the the curren currentt setting settings. s. (In this illustration, illustrati on, each section is shown with all its displays ON for the purpose of explanation.)
3. ECO ECONO NO button button:: ECONO operation (page 16.) 4. POWE POWERFUL RFUL button button:: POWERFUL operation (page 14.) 5. TEMPERA TEMPERATURE TURE adjustment buttons: • It change changes s the temper temperatu ature re settin setting. g. 6. ON/O ON/OFF FF butto button: n: • Press this button once to start operation. Press once again to stop it.
7. MODE selec selector tor button: button: • It select selects s the the opera operatio tion n mode. mode. (AUTO/DRY/COOL/HEAT/FAN) (AUTO/DRY/COOL/HEAT/F AN) (page 10.)
8. QUIET QUIET button button:: OUTDOOR UNIT QUIET operation (page 15.) 9. FA FAN N setting setting button: button: • It select selects s the air air flow flow rate sett setting ing.. (page 12.) 10. SWIN SWING G butto button: n: 11.. MOLD PROOF 11 PROOF button: button: • MOL MOLD D PROO PROOF F oper operat atio ion n (page 17.) 12. SENS SENSOR OR butto button: n: INTELLIGENT EYE operation (page 18.) 13. ON TIMER TIMER button button:: (page 21.) 14. OFF TIME TIMER R button: button: (page 20.) 15. TIME TIMER R Setting Setting button: button: • It chang changes es the the time time set settin ting. g. 16. TIME TIMER R CANCEL CANCEL button: button: • It cance cancels ls the the timer timer sett setting. ing. 17. CLOC CLOCK K butto button: n: (page 9.) 18. RESE RESET T butto button: n: • Res Restart tart the uni unitt if it free freezes zes.. • Use a thin thin obje object ct to to push. push.
6
48
Room Air Conditioners E-Series
ED04-805
Operation Manual
Preparation Before Operation
To set the batteries 1. Sli Slide de the fron frontt cover cover to take take it off off.. 2. Set two dry batt batteri eries es (AAA) (AAA).. 3. Set the fron frontt cover cover as befor before. e.
ATTENTION About batteries • When replacing the batteries, use batteries of the same type, and replace the two old batteries together. • When the system is not used for a long time, take the batteries out. • We recommend replacing once a year, although if the remote controller display begins to fade or if reception deteriorates, please replace with new alkali batteries. Do not use manganese batteries. • The attached batteries are provided for the initial i nitial use of the system. The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
7
Room Air Conditioners E-Series
49
Operation Manual
ED04-805
Preparation Before Operation
To operate the remote controller • To use the remote remote control controller ler,, aim the transmitte transmitterr at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate. • Do not drop the remote controller. Do not get it wet. • The maximu maximum m distance distance for commun communication ication is about 7m.
Receiver
To fix the remote controller holder on the wall 1. Choose Choose a place place fro from m where where the the sigsignals reach the unit. 2. Fix the the holder holder to a wall, wall, a pillar pillar,, etc. with the screws supplied with the holder.
Remote controller holder Set.
3. Place Place the remot remote e control controller ler in in the remote controller holder. • To remove, pull it upwards.
ATTENTION About remote controller • Never expose the remote controller to direct sunlight. • Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth. • Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult the shop if that is i s the case. • If the remote control signals happen to operate another appliance, move that appliance to somewhere else, or consult the shop.
8
50
Room Air Conditioners E-Series
ED04-805
Operation Manual
To set the clock 1. Pr Press ess “CL “CLOC OCK K butt button” on”.. is displayed. blinks.
2. Press Press “TIMER “TIMER sett setting ing but button ton” ” to set the clock to the present time. Holding down “ ” or “ ” button rapidly increases or decreases the time display.
3. Pr Press ess “CL “CLOC OCK K butt button” on”..
ECONO
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
blinks.
2
CANCEL
ON
Turn the breaker ON • Turning ON the breaker opens the flap, then closes it again. (This is a normal procedure.)
1, 3
OFF TIMER
NOTE Tips for saving energy • Be careful not to cool (heat) the room too much. Keeping the temperature setting at a moderate level helps save energy. • Cover windows with a blind or a curtain. Blocking sunlight and air from outdoors increases the cooling (heating) effect. • Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
Recommended temperature setting
For cooling:26 C – 28 C For heating:20 C – 24 C °
°
°
Please note • The air conditioner always consumes consumes 15-35 watts of electricity even while it is not operating. • If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF. • Use the air conditioner in the following conditions. Mode
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature:10 to 46˚C Indoor temperature: 18 to 32˚C 32˚C Indoor humidity: 80% max.
• A safety device may may work to stop the operation. operation. (In multi system, it may work to stop the operation of the outdoor unit only.) • Condens Condensation ation may occur occur on the indoor unit and drip. drip.
HEAT
Outdoor temperature:–10 to 20˚C Indoor temperature: 10 to 30˚C 30˚C
• A safety device may may work to stop the operation. operation.
DRY
Outdoor temperature:10 to 46˚C Indoor temperature: 18 to 32˚C 32˚C Indoor humidity: 80% max.
• A safety device may may work to stop the operation. operation.
• Condens Condensation ation may occur on the indoor indoor unit and drip.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
9
Room Air Conditioners E-Series
51
Operation Manual
ED04-805
AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode.
To start operation 1. Press Press “MODE “MODE sele selecto ctorr butt button” on” and select a operation mode. • Each pressi pressing ng of the button button advan advances ces the the mode setting in sequence.
4
ECONO
: AUTO POWERFUL
: DRY
ON/OFF TEMP
2, 3 1
: COOL MODE FAN SWING QUIET MOLD PROOF SENSOR
: HEAT : FAN
5 CANCEL
ON
OFF TIMER
2. Pr Press ess “ON “ON/O /OFF FF but butto ton” n” . • The OPER OPERA ATIO TION N lamp lamp lights lights up. up.
To stop operation 3. Pres Press s “ON/O “ON/OFF FF butt button” on” agai again. n. • Then OPERATION lamp goes off.
To change the temperature setting 4. Press “TEMPER “TEMPERA ATURE adjustmen adjustmentt button”. DRY or FAN mode
AUTO or COOL or HEAT mode
Press “ “ The temperature setting is not variable.
” to raise the temperature and press
” to lower the temperature.
Set to the temperature you like.
10
52
Room Air Conditioners E-Series
ED04-805
Operation Manual
To change the air flow rate setting 5. Pre Press ss “FAN “FAN setti setting ng butt button”. on”. DRY mode
AUTO or COOL or HEAT or FAN mode Five levels of air flow rate setting from “
The air flow rate setting is not variable.
plus “
”“
” to “
”
” are available.
• Ind Indoor oor uni unitt quiet quiet ope operati ration on When the air flow is set to “ ”, the noise from the indoor unit will become become quieter. Use this when making the t he noise quieter. The unit might lose capacity when the air flow rate is set to a weak level.
NOTE Note on HEAT operation • Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes becomes smaller smaller in lower outdoor temperatures. temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in combination with the air conditioner. • The heat pump system heats the room by circulating circulati ng hot air around all parts of the room. After the start of heating operation, it takes some time before the room gets warmer. • In heating operation, frost may occur on the outdoor outdoor unit and lower the heating heating capacity. In that case, the system switches into defrosting operation to take away the frost. • During defrosting operation, hot air does not flow fl ow out of indoor i ndoor unit. Note on COOL operation
• This air conditioner cools the room by blowing blowing the hot air in the room outside, so if the outside temperature is high, performance drops. Note on DRY operation
• The computer chip works to rid the room of humidity while maintaining the temperature as much as possible. It automatically controls temperature and fan strength, so manual adjustment of these functions is unavailable. Note on AUTO operation • In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the room temperature at the start of the operation. • The system automatically automatically reselects setting at a regular interval to bring bri ng the room temperature to usersetting level.
• If you do not like AUTO operation, you can manually select the operation mode and setting you like. Note on air flow rate setting • At smaller air flow fl ow rates, the cooling (heating) effect is also smaller.
11
Room Air Conditioners E-Series
53
Operation Manual
ED04-805
Adjusting the Air Flow Direction You can adjust the air flow direction to increase your comfort.
To adjust the horizontal blades (flaps) 1. Pr Press ess “SW “SWIN ING G butt button on”. ”. • “
” is dis isp pla lay yed on the LCD an and d th the e
flaps will begin to swing. ECONO
2. When the flap flaps s have have reache reached d the the desired position, press “SWING button” once more. • The flaps will stop moving. • “
” dis disa appears fr fro om th the e LCD.
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
1, 2
CANCEL
ON OFF TIMER
12
54
Room Air Conditioners E-Series
ED04-805
Operation Manual
To adjust the vertical blades (louvres)
Hold the knob and move the louvres. (You will find a knob on the left-side and the right-side blades.) • When the unit unit is installed installed in in the corner corner of a room, room, the direction of the louvers should be facing away from the wall. If they face the wall, the wall will block off the wind, causing the cooling (or heating) efficiency to drop.
Notes on flaps and louvres angles • When “ SWING button ” is selected, the flaps swinging range depends on the operation mode. (See the figure. ) • If the unit is operated operated after being being stopped stopped with the flaps pointed down in cooling or dry operation, the flaps will automatically move to a horizontal position after about one hour to prevent condensation from forming on them. ATTENTION • Always use a remote controller to adjust the flaps angle. If you attempt to move it forcibly with hand when it is swinging, the mechanism may be broken. • Be careful when when adjusting the louvres. Inside the air outlet, a fan is rotating at a high speed. speed.
13
Room Air Conditioners E-Series
55
Operation Manual
ED04-805
POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity .
To start POWERFUL operation 1. Pres Press s “POW “POWERF ERFUL UL butt button”. on”. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the settings which were used before POWERFUL operation. • Whe When n using using POWERFUL POWERFUL oper operatio ation, n, there are some functions which are not available. • “
” is displayed on the LCD.
To cancel POWERFUL operation 2. Press Press “POW “POWER ERFU FUL L butto button” n” again. • “
ECONO
POWERFUL
ON/OFF TEMP
1, 2 MODE FAN SWING QUIET MOLD PROOF SENSOR
CANCEL
ON OFF TIMER
” disappears from the LCD.
NOTE Notes on POWERFUL operation
• POWERFUL Operation cannot cannot be used together with ECONO or QUIET Operation. Priority is given to the function of whichever button is pressed last. • POWERFUL Operation can only only be set when the unit is running. Pressing the operation stop button button cause causes s the setting settings s to be cancele canceled, d, and and the “ ” disappea disappears rs from from the LCD. • In COOL and HEAT mode To maximize the cooling (heating) ( heating) effect, the capacity of outdoor unit must be increased and the air flow rate be fixed to the maximum setting. The temperature and air flow settings are not variable. • In DRY mode The temperature setting is lowered by 2.5˚C and the air flow rate is slightly increased. • In FAN mode The air flow rate is fixed to the maximum setting.
14
56
Room Air Conditioners E-Series
ED04-805
Operation Manual
OUTDOOR UNIT QUIET Operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is convenient during night.
To start OUTDOOR OUT DOOR UNIT QUIET operation 1. Pr Press ess “QU “QUIET IET but butto ton” n”.. • “
” is is displayed on the LCD. ECONO
To cancel OUTDOOR UNIT QUIET operation 2. Pres Press s “QUIE “QUIET T button button” ” again. again. • “
” disappears from the LCD.
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
1, 2
CANCEL
ON OFF TIMER
NOTE Note on OUTDOOR UNIT QUIET operation • This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.) • POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time. Priority is given to the function of whichever button is pressed last.
15
Room Air Conditioners E-Series
57
Operation Manual
ED04-805
ECONO Operation ECONO operation is a function which enables efficient operation by lowering the maximum power consumption value.
To start ECONO operation 1. Pr Press ess “EC “ECON ONO O butt button on” ”. •“
” is is dis disp pla lay yed on on th the LCD LCD..
To cancel ECONO operation 2. Pre Press ss “ECO “ECONO NO but button ton” ” again again.. •“
” di disa sapp ppea ears rs fr from om th the e LC LCD. D.
1, 2
ECONO
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
CANCEL
ON OFF TIMER
NOTE • ECONO Operation can only be set when the unit is running. Pressing the operation stop button but ton cause causes s the setting settings s to be cancele canceled, d, and the the “ ” disappe disappears ars from from the LCD. LCD. • ECONO operation is a function which enables efficient efficient operation by limiting the power consumption of the outdoor unit (operating frequency). • ECONO operation functions in AUTO, COOL, DRY, DRY, and HEAT HEAT modes. • POWERFUL operation and ECONO operation cannot be used at the same time. Priority is given to the function of whichever button is pressed last. • Power consumption may not drop even if ECONO operation is used, when the level of power consumption is already low.
16
58
Room Air Conditioners E-Series
ED04-805
Operation Manual
MOLD PROOF Operation MOLD PROOF operation is a function which reduces the spread of mold by using Fan mode to lower the humidity inside the indoor unit.
To set MOLD PROOF operation 1. Press Press and and hold hold the the MOLD MOLD PRO PROOF OF button for two seconds. •“
” is is dis displ play ayed ed on th the e LCD LCD..
To cancel MOLD PROOF operation 2. Press Press and and hold hold the the MOLD MOLD PRO PROOF OF button for two seconds one more time. •“
” di disa sapp ppea ears rs fr from om th the e LC LCD. D.
ECONO
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
1, 2 CANCEL
ON OFF TIMER
NOTE • MOLD PROOF operation will operate for approximately one hour after dry or cooling mode is turned off. • This function is not designed to remove existing dust or mold. mold. • MOLD PROOF operation is not available when the unit is turned off using the OFF TIMER.
17
Room Air Conditioners E-Series
59
Operation Manual
ED04-805
INTELLIGENT EYE Operation “INTELLIGENT EYE” is the infrared sensor which detects the human movement.
To start INTELLIGENT EYE operation 1. Pr Press ess “SEN “SENSO SOR R butto button”. n”. • “
” is is dis disp pla lay yed on th the e LCD.
To cancel the INTELLIGENT EYE operation 2. Pres Press s “SENS “SENSOR OR butt button” on” agai again. n. • “
” disappears from the LCD.
ECONO
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
[EX.] When somebody in the room
1, 2
CANCEL
ON OFF
• No Norm rmal al op oper erat atio ion n
TIMER
When nobody in the room • 20 min min.. afte afterr, start start energy
saving
operation.
Somebody back in the room • Bac Back k to nor normal mal ope operat ration ion..
18
60
Room Air Conditioners E-Series
ED04-805
Operation Manual
“INTELLIGENT EYE” is useful for Energy Saving Energy saving operation • Change the temperature –2 C in heating / +2 C in cooling / +2 C in dry mode from set temperature. • Decrease the air flow rate slightly in fan operation. (In FAN mode only) °
°
°
Notes on “INTELLIGENT EYE” • App Applica licatio tion n range range is as as follows follows..
• Sensor Sensor may not detect moving objects objects further further than 7m away. away. (Check the application application range) range) • Senso Sensorr detection sensitivi sensitivity ty changes changes according according to indoor unit location, location, the speed of passersby,, temperature range, etc. ersby • The sensor sensor also mistakenly mistakenly detects pets, pets, sunlight, fluttering fluttering curtains curtains and light reflected reflected off of mirrors as passersby passersby.. • INTELL INTELLIGENT IGENT EYE operatip operatipon on will not go on on during powerfu powerfull operation. operation. • Night set set mode (page (page 20.) will not not go on during during you use INTELLIGENT INTELLIGENT EYE EYE operation. operation.
CAUTION • Do not place large objects objects near the the sensor sensor.. Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect objects it shouldn’t as well as not detect objects it should. • Do not hit or violently violently push the INTELLIGENT INTELLIGENT EYE sensor sensor.. This can lead to damage damage and malfunction.
19
Room Air Conditioners E-Series
61
Operation Manual
ED04-805
TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination.
To use OFF TIMER operation • Check Check that that the the clock clock is corr correct ect.. If not, set the clock to the present time. (page 9.)
1. Pr Press ess “OFF “OFF TIMER TIMER but butto ton”. n”. is displayed.
ECONO
POWERFUL
ON/OFF TEMP
blinks.
2. Press Press “TIME “TIMER R Setti Setting ng butto button” n” until the time setting reaches the point you like. • Every press pressing ing of either either butto button n increase increases s or decreases the time setting by 10 minutes. Holding down either button changes the setting rapidly.
MODE FAN SWING QUIET MOLD PROOF SENSOR
CANCEL
ON
2 4
OFF TIMER
3. Press Press “OF “OFF F TIMER TIMER butt button on” ” again.
1, 3
• The TIM TIMER ER lamp lamp ligh lights ts up.
To cancel the OFF TIMER operation 4. Pr Press ess “CA “CANC NCEL EL butt button on”. ”. • The TIMER lamp goes off.
NOTE • When TIMER is set, the present time is not displayed. • Once you set ON, OFF TIMER, the time setting is kept in the memory. (The memory is canceled when remote controller batteries are replaced.) • When operating the unit via the ON/OFF Timer, the actual length of operation may vary from the time entered by the user. (Maximum approx. 10 minutes) NIGHT SET MODE When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5˚C up in COOL, 2.0˚C down in HEAT) to prevent excessive cooling (heating) for your pleasant sleep.
20
62
Room Air Conditioners E-Series
ED04-805
Operation Manual
To use ON TIMER operation • Check that the the clock clock is is correct. correct. If not, set the clock to the present time (page 9.).
1. Pr Press ess “ON “ON TIME TIMER R butto button” n”.. is displayed. blinks.
2. Press Press “TIME “TIMER R Setti Setting ng butto button” n” until the time setting reaches the point you like. • Every Every press pressing ing of of either either butto button n increases or decreases the time setting by 10 minutes. Holding down either button changes the settin g rapidly.
3. Press Press “ON “ON TIME TIMER R butto button” n” again.
ECONO
POWERFUL
ON/OFF TEMP
MODE FAN SWING QUIET MOLD PROOF SENSOR
• The TIMER lamp lights up. CANCEL
ON
1, 3 4
OFF TIMER
2
To cancel ON TIMER operation 4. Pr Press ess “CA “CANC NCEL EL butt button on”. ”. • The TIMER lamp goes off.
To combine ON TIMER and OFF TIMER • A sample setting for combining the two timers is shown below. below.
ATTENTION In the following cases, set the timer again. • After a breaker has turned OFF. • After a power failure. • After replacing batteries in the remote controller.
21
Room Air Conditioners E-Series
63
Operation Manual
ED04-805
Care and Cleaning CAUTION
Before cleaning, be sure to stop the operation and turn the breaker b reaker OFF. OFF.
Units
Indoor unit, Outdoor unit and Remote controller 1. Wip Wipe e them them with with dry sof softt cloth. cloth.
Front panel 1. Op Open en the the fro front nt pan panel. el. • Hold the panel by the tabs on the two sides and lift it unitl it stops with a click.
2. Rem Remov ove e the fro front nt panel panel.. • Lift the front panel up, up, slide slide it slightly slightly to the right, and remove it from the horizontal axle .
3. Cl Clean ean th the e front front pan panel. el. • Wipe Wipe it with with a soft soft cloth soa soaked ked in water water.. • On Only ly neu neutral tral deterg detergent ent may may be be used. used. • In case case of wash washing ing the pane panell with water water,, dry it with with cloth, dry it up in the shade after washing.
4. At Atta tach ch the the front front pane panel. l. • Set the the 2 keys keys of the the front front panel panel into the the slots and and push them in all the way. • Close the front front panel panel slowly slowly and push the panel panel at the 3 points. ( 1 on each side and 1 in the middle.)
Fit the key into the slot.
CAUTION • • • •
Don’t touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury. When removing removing or attaching the front panel, use a robust and stable stool and watch your steps carefully. carefully. When removing or attaching the front panel, support the panel securely with hand to prevent it from falling. For cleaning, do not use hot water above 40˚C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff. • After cleaning, make sure that the front f ront panel is securely fixed. fi xed.
24
64
Room Air Conditioners E-Series
ED04-805
Operation Manual
Filters 1. Open the fron frontt panel. panel. (page (page 24.) 2. Pu Pull ll out out the the air fil filter ters. s. • Push a little upwards the tab at the center of each air filter, then pull it down.
3. Take off off the Titan Titanium ium Apati Apatite te Photocatalytic Air-Purifying Filter Filter..
Titanium Apatite Photocatalytic Air-Purifying Filter
• Hold the recessed parts of the frame and unhook the four claws.
Air filter
Filter frame
4. Clea Clean n or repla replace ce each each filte filterr. See figure.
Tab
5. Set the air air filter filter and and Titan Titanium ium Apa Apatite tite Photocatalytic Air-Purifying Filter as they were and close the front panel.
Push
• Insert claws of the filters into slots of the front f ront panel. Close the front panel slowly and push the panel at the 3 points. (1 on each side and 1 in the middle.)
Air Filter 1. Wash the air filters with water water or clean them them with vacuum cleaner. • If the dust does not come off easily, wash them with neutral detergent thinned with lukewarm water, then dry them up in the shade. • It is recommended to clean the air filters every two weeks.
Titanium Apatite Photocatalytic Air-Purifying Filter.
Tab
The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed by washing it with water w ater once every 6 months. We recommend replacing it once every 3 years.
[ Maintenance ] 1. Remove dust dust with a vacuum vacuum cleaner cleaner and wash wash lightly with water water.. 2. If it is very dirty dirty,, soak it for 10 to 15 minutes minutes in water mixed mixed with a neuneutral cleaning agent. 3. Do not remove remove filter filter from frame when when washing washing with water water.. 4. After washing, shake off remainin remaining g water and dry in the shade. shade. 5. Since the material material is made made out of paper paper,, do not wring wring out the the filter when removing water from it.
[ Replacement ] 1. Remove the the tabs on the the filter frame frame and replace replace with a new filter filter.. • Dispos Dispose e of the old filter as flammable flammable waste. waste.
25
Room Air Conditioners E-Series
65
Operation Manual
ED04-805
NOTE • Operat Operation ion with dir dirty ty filter filters: s: (1) ca cannot de deodorize th the air air.. (2) ca cannot cle clea an th the air air.. (3) results in poor heating or cooling. (4) may cause odour. • To order Titanium Titanium Apatite Apatite Photocatalytic Photocatalytic Air-Purifying Air-Purifying Filter Filter contact to the service service shop there you bought the air conditioner. • Dispo Dispose se of of old filters as burnab burnable le waste. waste. Item
Titanium Apatite Photocatalytic Air-Purifying Filter. (without frame) 1 set
Part No. KAF970A46
Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets i nlets and the outlets of the indoor unit and the outdoo outdoorr unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation. • If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.
Before a long idle period 1. Operate the the “Fan only” only” for several several hours on a fine fine day to dry dry out the inside. • Press “MODE selector selector button” and select “Fan”opera “Fan”operation. tion. • Press “ON/OFF “ON/OFF button” button” and start operation operation..
2. After operation operation stops, stops, turn off the breaker breaker for the the room air conditioner conditioner.. 3. Clea Clean n the air air filters filters and and set them them again. again. 4. Take out batteri batteries es from the the remote remote controller controller..
26
66
Room Air Conditioners E-Series
ED04-805
Operation Manual
Trouble Shooting Sh ooting These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Explanation
Operation does not start soon. • Wh When en ON/O ON/OFF FF butt button on was was pressed soon after operation was stopped. • Wh When en th the e mod mode e was was reselected.
• This is to protec protectt the air conditi conditioner oner.. You should wait for about 3 minutes.
Hot air does not flow out soon after the start of heating operation.
• The air conditio conditioner ner is warming warming up. up. You You should should wait for for 1 to 4 minutes. (The system is designed to start discharging air only after it has reached a certain temperature.)
The heating operation stops suddenly and a flowing sound is heard.
• The system system is taking taking away away the frost frost on the the outdoor outdoor unit. You should wait for about 3 to 8 minutes.
The outdoor unit emits water or steam.
In HEAT mode • The frost frost on the the outdoor outdoor unit melts melts into water or steam steam when the air conditioner is in defrost operation. In COOL or DRY mode • Moistu Moisture re in the air condense condenses s into water water on the the cool surface of outdoor unit piping and drips.
Mist comes out of the indoor unit.
This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.
The indoor unit gives out odour.
This happens when smells of the room, furniture, or cigarettes are absorbed into the unit and discharged wit h the air flow. (If this happens, we recommend you to have the indoor unit washed by a technician. Consult the service shop where you bought the air conditioner.)
The outdoor fan rotates while the air conditioner is not in operation.
After operation is stopped: • The outdoor outdoor fan continue continues s rotating rotating for for another another 60 seconds for system protection. While the air conditioner is not in operation: • When the the outdoor outdoor temperature temperature is very high, the the outdoor outdoor fan starts rotating for system protection.
The operation stopped suddenly. (OPERATION lamp is on.)
For system protection, the air conditioner may stop operating on a sudden large voltage fluctuation. It automatically resumes operation in about 3 minutes.
27
Room Air Conditioners E-Series
67
Operation Manual
ED04-805
Check again. Please check again before calling a repair person.
Case The air conditioner does not operate. (OPERATION lamp is off.)
Check
• Hasn’t a breaker breaker turned turned OFF OFF or a fuse blown? blown? • Isn Isn’t ’t itit a pow power er fail failure ure? ? • Are batteries batteries set in the remote remote contro controller? ller? • Is the the timer timer setti setting ng corr correct ect? ?
filters ers cle clean? an? Cooling (Heating) effect is poor. • Are the air filt • Is there anyth anything ing to block block the air inlet or the outlet outlet of the the indoor and the outdoor units? • Is the temper temperature ature setting appro appropriate priate? ? • Are the the window windows s and doo doors rs close closed? d? • Are the air air flow rate rate and the the air direction direction set set appropria appropriately? tely? • Is the unit set set to the INTELLIG INTELLIGENT ENT EYE EYE mode? mode? (page 18.)
Operation stops suddenly. (OPERATION lamp flashes.)
• Are the air filt filters ers cle clean? an?
An abnormal functioning happens during operation.
• The air condi conditioner tioner may may malfunction malfunction with with lightning lightning or radio radio waves. Turn the breaker OFF, OFF, turn it ON O N again and try operating the air conditioner with the remote controller.
• Is there anyth anything ing to block block the air inlet or the outlet outlet of the the indoor and the outdoor units? Clean the air filters or take all obstacles away and turn the breaker OFF. OFF. Then turn it ON again and try operating the air conditioner with the remote controller. If the lamp still f lashes, call the service shop where you bought the air conditioner.
28
68
Room Air Conditioners E-Series
ED04-805
Operation Manual
Call the service shop immediately.
WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner.
Do not attempt to repair or modify the air conditioner by yourself. Incorrect work may result in electric shocks or fire. Consult the service shop where you bought the air conditioner.
If one of the following symptoms takes place, pl ace, call the service shop immediately.
The power cord is abnormally hot or damaged. An abnormal sound is heard during operation. The safety breaker, a fuse, or the earth leakage breaker cuts off the operation frequently. A switch or a button often fails to work properly. There is a burning smell. Water leaks from the indoor unit.
After a power failure The air conditioner automatically resumes operation in about 3 minutes. mi nutes. You should should just wait for a while.
Turn the breaker OFF and call the service shop.
Lightning If lightning may strike the neighbouring area, stop operation and turn the breaker O FF for system protection.
We recommend periodical maintenance. In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user. For specialist maintenance, contact the service shop where you bought the air conditioner. The maintenance cost must be born by the user.
29 3P194539-3
Room Air Conditioners E-Series
69
Optional Accessories
ED04-805
14.Optional Accessories 14.1 Option ion List Option Name
Note:
70
Kit Name
Applicable Model
KRC72
Indoor Unit
KRP413A1S
Indoor Unit
1
Centra Centraliz lized ed Contro Controll Boar Board-U d-Up p to to 5 Rooms Rooms ★1
2
Wiring Adaptor for Time Clock / Remote Control ★2 (Normal Open Pulse Contact / Normal Open Contact)
3
Cent Centra rall Remo Remote te Con Contr trol olle lerr ★1
DCS302CA61
Indoor Unit
4
Unif Unifie ied d ON/O ON/OFF FF Cont Contro roll ller er ★1
DCS301BA61
Indoor Unit
5
Sche Schedu dule le Tim Timer er Con Contr trol olle lerr ★1
DST301BA61
Indoor Unit
6
Interface Adaptor for Room Air Conditioner
KRP928B2S
Indoor Unit
7
Titanium Apatite Photocatalytic Air-Purifying Filter (without Frame)
KAF970A46
Indoor Unit
8
The Remote Controller Loss Prevention with the Chain
KKF917A4
Indoor Unit
9
Drain Plug
KKP937A4
Outdoor Unit
10
Air Direction Adjustment Grille
KPW937A4
Outdoor Unit
★1
Wiring Wiring adap adaptor tor is also also require required d for each each indoor indoor unit. unit. Time clock clock and and other other devices devices ; obtain obtained ed locally locally.. ★2 Time
Room Air Conditioners E-Series
ED04-805
Optional Accessories
14.2 14.2 Inst Insta allat llatio ion n Man Manual ual 14.2 14.2.1 .1 KRP4 KRP413 13A1 A1S S 1. Functions and Features
Safety Precautions Read these safety precautions carefully before installing the unit, and be sure to install the unit properly. This manual classifies precautions to the user into the following two categories. These warnings and cautions are for your safety. Follow them.
WARNING
Faulty installation can result in death or serious injury
CAUTION
Faulty installation can result in serious injury or other serious consequences.
Below is a key to symbols used in this manual. Be sure to follow instructions. Be sure to perform grounding work. Never attempt.
After installation is complete, test the unit to confirm that it is working properly, properly, and instruct the owner its proper use.
WARNING
Installation should be left to the dealer from whom you purchased the unit, or another qualified professionals. Install the unit securely according to the installation manual. Faulty installation may lead to electric shock or fire. Be sure to use the supplied or specified parts. Using other parts may lead to electric shock or fire. Install the unit securely in a location that will support its weight. If installed in a poor location or improperly installed, the unit may not work as intended. For electrical work, follow local electric standards and the installation manual. Faulty installation may lead to fire or electric shock. Do not bundle the power cord, or attempt to extend it by splicing it with another cord or by using an extension cord. Do not place any other load on the power circuit used for the unit. Improper wiring may lead to electric shock, heat generation or fire. Use dedicated wiring for all electrical connections, and be sure to arrange the wiring so that force applied to the wiring will not damage the terminals. Poor wiring or installation may cause electric shock, heat generation or fire.
On/Off setting Switching between Instantaneous Contact/Normal Contact Connection with five-room central controller (KRC72 for oversea model) Connection with fan coil remote controller Automatic reset after power failure Output of normal operation signals/malfunction signals
2. Field Wiring For interconnecting wiring, use Daikin KDC100A12 cable (not supplied) or other similar cable. The cable should have the specifications shown below.
Optional cable KDC100A12 (without connectors) Spec Specif ific icat atio ions ns:: 0.2 0.2 mm2 × 4 core (sheathed) Outer diameter: φ 5.3 Length: 100 m Colour: Grey Other cable (commercially available) Outer dia.
Remarks
Cable for instrumentation (IPVV) 0.3 mm2 × 4-core
Item
7.2 mm
Hard sheath
Microphone cord (MVVS) 0.3 mm 2 × 4-core
8.0 mm
Microphone cord (MVVS) 0.2 mm 2 × 4-core
6.5 mm
Microphone cord (MVVS) 0.15 mm 2 × 4-core
4.8 mm
Shielded
Intercom cable 0.65 mm 2 dia. × 4-core PVC jumper wire (TJVC) (from 0.5 mm dia. × 4 pcs.)
—
Not sheathed
Note 1: Keep any wiring wiring for the control control unit away from the power power cord to prevent prevent electrical noise. Note 2: Do not use cables cables shown above for for power cord, inter-unit inter-unit cord/cable cord/cable or power cord for lamps.
CAUTION
Before installation, unplug the air conditioner to ensure safety. Failure to do so may cause electric shock. Static electricity may damage electric components. Before connecting cables and communication lines, and operating the switches, be sure to discharge any electrical charge from your body (by, for example, touching the earth line) Do not install the unit in a location where it may be exposed to flammable gases. If gas leaks and build up around the unit, it may catch fire. Do not place the wiring close to the power cord, inter-unit cable, or pipes which generate noise. Treat the wiring with care.
Room Air Conditioners E-Series
71
Optional Accessories
ED04-805
Installation This product is available in two types. The KRP413A1S · KRP413AA1S is for installation in a case independent of the indoor unit, and the KRP413A1 is for installation within the indoor unit.
1. KRP413A1S · KRP413AA1S 1
3. Attaching Adaptor Case Assy (for KRP413A1S · KRP413AA1S)
Installation diagram
1 Adaptor case
Indoor unit PCB
Using the screws (to mount on a wall, etc.)
Use the 3 supplied screws to attach the case assy .
Adaptor case
S21
Indoor unit wiring
2
Local wiring or power cord, etc.
Install the adaptor case assy as close to the indoor unit as possible. Removing case front
Case front
Components
Adaptor
case assy assy (Adaptor (PCB) is attached in the adaptor case.)
Wiring
(approx. 0.8 m)
Screw Adaptor PCB Screw cover
Accessories
• Binding band (4 pcs.) • Securing tape for attaching to the indoor unit (2 sets) • Screws for attaching the adaptor case (4 pcs.) • Screws for attaching to the wall (3 pcs.)
Remove the screw cover, one of the screws and then the case front. Attach the case back to the surface by tightening the screws through the screw holes (one round hole, two long holes). After connecting the cables (refer to the following sections), replace the case front. Be careful not to damage the wiring in the case. Press in so that the prong catches the case back.
Installation manual
Wiring
2. KRP413A1 For this type, install the adaptor PCB within the indoor unit. The method of installation and connection vary depending on the model of the air conditioner. conditioner. See your air conditioner installation manual for details.
1
Screw
Screw cover
Components
Adaptor
PCB
Wiring
(approx. 0.25 m)
2
Using securing tape (to attach on the indoor unit)
Attach the adaptor case with the supplied securing tape. the case front (as for mounting on a wall). After connecting the cables (see the following sections), replace the case front. It can be screwed to the case back from the rear with the four supplied screws. Be careful not to damage the wiring in the case. Attach the hook side (loop side) of the included securing tape to the rear surface of the HA case, then attach the loop side (hook side) to the top of the air conditioner unit spaced at the same intervals.
Remove
Installation manual
Securing tape Hook side (loop side)
Securing tape Loop side (hook side) Indoor unit
To prevent the adaptor case assy from falling, do not use the securing tape for attaching it to a wall or other surface.
72
Room Air Conditioners E-Series
ED04-805
Optional Accessories
Wiring 1. Wiring
4. Connection with Remote Controller
Connect
one end of the wiring to connector S21 of the PCB in the indoor unit. Connect the other end of the wiring to connector S6 of the adaptor PCB. Connect field wiring according to the functions assigned to each connection terminal of the adaptor PCB. Secure all wires.
1
Example connections with three kinds of remote controllers are shown bellow. Note: These connections connections cannot cannot be used in combination. combination.
1
Gene Generi ric c rem remot ote e con contr trol olle lerr
Set SW1-1 to Off and select Operation Mode 1. SW1
Securing wires in the adaptor case assy (for KRP413A1S · KRP413AA1S)
ON OFF
Fasten with a tie-wrap so that wires will not come loose even if pulled. If the wire protrudes from this side, cut the cut-off section of the case front.
1
2
On/Off
2 1
Off
Inter unit cable (field wiring) Tie-wrap (to prevent the wires from coming loose)
The remote controller most recently used (local or air conditioner) takes precedence. Use a remote controller with a pulse width of 100 msec or more.
1
2
S 1
S 2
Power On/Off cannot be controlled from the unit’s remote controller. When power is restored after a power failure in this mode, On or Off is determined according to the current settings of the remote controller.
2
Operation
Securing wires in the indoor unit (for KRP413A1)
1 2
The method for securing wire varies depending on the model of the air conditioner. conditioner. See your air conditioner installation manual for details.
1
On
2
2. Automatic Reset After Power Failure
2
This PCB stores the following data in the event of a power failure (common features). On/Off (see Note 1) Operation modes Temperature setting Air flow rate On/Off status of remote controller
SW1 ON OFF 1
4
Terminal blocks A to E
Maximum length of the wiring is 100 m.
2
1 S 2 4
3 2
1 S 2 1
1
Moni Monito torr sig signa nall out outpu putt for for LED LED Locally procured parts 1
R D
LED
2
Item Manufacturer
S 4
Max 100 m
2
Five-r Five-room oom centra centrall contr controll oller er (KRC (KRC72) 72)
Five-room central controller
3. Monitor Signal Output (normal operation and malfunction)
1
S 2
Set SW1-1 to Off and select Operation Mode 1. The remote controller most recently used takes precedence.
(Note 1 When SW1-2 is in Off mode, the unit will not be activated.)
S 1
LED
Toshiba
D
Rohm
R
Type TLG208 (green) TLR208 (red) 1S2473 510 ohm 1/4W
Monitor signal output (normal operation and malfunction)using malfunction)using external relay contacts
3
Fan Fan coi coill rem remot ote e con contr trol olle lerr
Set SW1-1 to On and select Operation Mode 2. Most settings (power On/Off, air flow rate, mode change) cannot be made using the air conditioner’s remote controller. When power is restored after a power failure in this mode, On or Off is determined according to the current settings of the remote controller. When the Cooling /Heating mode is changed, use the air conditioner’s remote controller to adjust the temperature.
SW1 ON
S 8
+
DC12V – 1
S 5
2 3
OFF
L1
: Operation light
L2
: Malfunction light
1
2
1
S 1
H M L OFF
(+) MR1
(–)
L1
MR1
MR2
(–)
MR2
Max 100 m
External power supply for light
2
L2
1 S 2 2
Field supplied parts
Field procured parts (Recommended external relay contacts) Manufacturer
Type
Coil rated voltage
Coil resistance
Omron
MY relay
12 V DC
160 ohm ± 10%
Matsushita
HC relay
12 V DC
160 ohm ± 10%
Room Air Conditioners E-Series
Fan coil remote controller
1 S 3
2
On (When heating) Off
(When cooling)
Cooling/heating switch
73
Optional Accessories
ED04-805
Test Operation and Confirmation 1. When the System is Not Working Is the air conditioner working properly? Are the connectors of the wiring properly connected? Are the remote controller and field wiring properly connected? Are all switch settings correct? If there is nothing apparently wrong, conduct a diagnostic check using the following procedure.
Diagnostic check Defect in adaptor PCB. Defect in wiring. Defect in indoor unit’s PCB. Transmission error (between remote controller and indoor unit)
START
Is the “CPU Normal” light for the remote controller’s PCB flashing?
No
Yes
Is 12 V DC being supplied to No. 4 and No. 5 on S6 of the remote controller’s PCB?
No
Yes
Is 12 V DC being supplied to No. 4 and No. 5 on S21 of the indoor unit?
No
Yes
Is the malfunction light of the remote controller’s PCB on?
No
Yes
OR
2. Switch Settings and Connection Terminals
1 2 1 2 1 2 1 2
S 4 S 1 S 2 S 3
SW1-1
Selecting the operation mode
OFF
Operation mode 1 (Used with the exception of fan coil remote controller settings)
ON
Operation mode 2 (Used with fan coil remote controller settings)
OFF
Al wa ways Of Off
SW1-2
Selecting On/Off when power is restored after a power failure
ON
Off if operation was in Off mode before power failure; On if operation was in On mode before power failure
S 1 8 2 1 S 2 5 3
SW1-1: OFF (Operation mode 1)
SW1
1 2 OFF ON
S6
I ns ns ta tant an aneo us us c on onta ct ct
N or or ma mal c on ont ac act
S1 (1) - S2 (1)
OPEN
CLOSE
S1 (1) - S1 (2)
Pulse input On/Off switching
OPEN, Not activated
S2 (2), S3
S2
S1, S2 OPEN
S3
S1 (1) - S1 (2) CLOSE
On, airflow: L tap
S1 (1) - S2 (1) CLOSE
On, airflow: M tap
S1 (1) - S2 (2) CLOSE
On, airflow: H tap
SW1-1: ON (Operation mode 2)
S3 (With the remote controller only) CPU normal operation monitor (Flashes when the operation is normal.)
CLOSE, Activated
S1
S4 S5
Not activated
OPEN, Cooling CLOSE, Heating
(1) - (2)
Voltage on (DC12 V), normal operation light output
(1) - (2)
Normal operation light output (power for light required)
(1) - (3)
Malfunction light output (power for light required)
S6 connector S8
Not used
(+) - (–)
Connect with connector S21 on the PCB of the indoor unit Relay DC 12 V power supply terminal (Field supplied parts)
2P031616-1B
74
Room Air Conditioners E-Series
ED04-805
Optional Accessories
14.2 14.2.2 .2 KRP9 KRP928 28B2 B2S S 1.Overview,, Features and Compatible Models 1.Overview
Safety Precautions Read
This kit is the interface required when connecting the central controller and a Daikin Room Air Conditioner. Use of the central controller makes it possible to perform the following monitoring and operations. It is compatible with room air conditioners which have an HA connector S21.
these Safety Precautions carefully to ensure correct installation.
This manual classifies precautio ns into WARNING and CAUTION.
1.Run / stop for the central controller and wired remote controller, operating mode selection, and temperature can be set. 2.The operating status, any errors, and the content of those errors can be monitored from the central controller and wired remote controller. 3.Run / stop for the central controller and wireless remote controller, operating mode selection, and the temperature setting can be limited by the central controller. 4.Zone control can be performed from the central controller. 5.The unit can remember the operating status of the air conditioner before a power outage and then start operating in the same status when the power comes back on. 6.Card keys, operating control panels, and other constant / instantaneous connection-compatible equipment can be connected. 7.The Operating / error signals can be read. 8.HA JEM-A-compatible equipment can be connected. 9.The indoor temperature can be monitored from the Ve-up controller.
WARNING : Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury.
CAUTION : Failure to follow CAUTION may result in serious injury or property damage, and in certain circumstances circumstances,, may result in a grave consequence.
Be sure to follow all the precautions below ; they are all important for ensuring safety safety..
WARNING
Installation should be left to the dealer or another qualified professional.
Install the set according to the instructions given in this manual.
Be sure to use the standard attachments or the genuine parts.
Disconnect power to the connected equipment before starting installation.
Improper installation installation by yourself may cause malfunction, electrical shock, or fire. Incomplete or improper installation may cause malfunction, electrical shock, or fire.
Precaution 1.When reading the Operating / error signals, a separate external power source (DC 12V) is needed. 2.A separate timer power source (DC 16V) is needed when using the schedule timer independently, independently, and not in conjunction with other central controllers. 3.The range of temperatures that can be set from the central controller is 18 °C to 32°C in cooling and 14 °C to 28°C in heating. 4.Fan operation cannot be selected from the central controller or wired remote controller. 5.Group control (i.e., control of multiple indoor units with a single remote controller) is not available. 6.Monitoring is not available of the thermo status, compressor operating status, indoor fan operating status, electric heater, or humidifier operating status. 7.Forced thermo off, filter sign display and reset, fan direction and speed settings, air conditioning fee management, energy savings instructions, low-noise instructions, and demand instructions cannot be made.
Use of other parts may cause malfunction, electrical cal shock, or fire. Failure to do so may cause malfunction, electrical shock, or fire.
CAUTION
An earth leakage circuit breaker should be installed.
Do not install the set in a location where there is danger of exposure to inflammable gas.
To prevent damage due to electrostatic discharge, touch your hand to a nearby metal object (doorknob, aluminum sash, etc.) to discharge static electricity from your body before touching this kit.
If the breaker is not installed, electrical shock may occur.
Gas accumulated around the unit at the worst may cause fire.
2.Component Parts and Separately-Sold Parts which are Required This kit includes the following components. Check to ensure that none of these are missing.
Static electricity can damage this kit.
Parts Kit assy PCB is in the housing.
Lay this cable separately from other power cables to avoid external electrical noises.
After
installation is complete, test the operation of the PCB set to check
Q’ty
1
Screw cover
for problems, and explain how to use the set to the end-user.
Parts
Q’ty
Connection harness (about 1.6m)
1set
Mounting screws
3pcs.
Binding band
1pc.
Installation manual
1set
3.Names of Parts and Electric Wiring Wiring
Lower group number switch (SW1)
Room air conditioner indoor unit
Service monitor (LED1: green) When the CPU is working properly, the LED flashes.
Upper group number switch (SW2-1to 3) Operation when recovering from a power outage mode switch (SW2-4)
Japanese unit / Overseas unit Setting switch (SW3-3)
DAIKIN KIN
1 1 23 2 3 4 1 23 2 3 4 ON
To HA connector (S21)
Once the switches are set and the wiring complete, secure the case using the included screws.
OFF
0
SW1
Momentary contact / constant contact Selection switch (SW3-2)
4 3 2 1
SW2
Forced stop Settings switch (SW3-1)
LED1 N F F
O O
Supplied connection harness
Power supply terminal (S8) Connect an external DC 12V power supply only when reading the Operating / error display.
SW3 S6 Tes1
S1 S16
Cable available field supply (See the installation manual of the central remote controller)
F1
S8
F2
A ca ca bl bl e f ie ld su sup pl pl y
Non polarity Included in the Drain Up Kit.
Central controller equipment DCS302 Series DCS301 Series DCS601 Series DST301 Series KRC65, KRC72, KDC100A10, and KDC101B Series cannot be connected.
In case that a central remote controller is connected
S5
S19
A ca ca bl bl e f ie ld su su pp pp ly
Separately sold remote control code (quadplex) KRCW101A Series
Tele-con (Field supply)
Remote controller BRC944 Series
Card key (Field supply) Operating control panel (Field supply)
Operatingmonitoring equipment (Field supply)
The adapter included with the remote controller is not used.
In case that the device coping with HA JEM-A is c onnected
Room Air Conditioners E-Series
Connecting a Wired Remote Controller
Connecting a Momentary / constant Contact Input Equipment
Reading the Operating / error Display
75
Optional Accessories
ED04-805
5.Control Codes
4.Switch Settings Turn the power on after all the switches have been set. Settings made while the power is on are invalid.
NOTE
Open the Kit’s case and set the switches on the circuit board. (1) For Overseas / Japanese unit setting (SW3-3) Room air conditioners, different methods are used for setting the temperature in automatic mode, so this switch needs to be set. Destination
SW3-3 setting
Japan
OFF (Factory setting)
What Happens
Overseas
ON
“Automatic” operation is available from the central controller.
side.) Do not set more
However, these settings do not need to be made when using the schedule timer However, independently. (The settings are needed when used in conjunction with another DCS Series central controller. controller.)) In this case, the schedule timer performs an auto address after the power is turned on, so new group numbers are automatically set. Settings Settings made using the switches will be overwritten. SW2 Upper setting group NO.
Lower SW1 setting group NO. 1 1 2 3 4
1— 0
Lower SW1 setting group NO. 1 2 3 4
0 0
0 8
1 2 3 4
2— 1 2 3
1 2 3 4
0 1 1 2 3 4
3— 1 2 3
Control code
ON / OFF control is rejected Only OFF control is accepted
0,1,3 10,11 2 12–19 4 5 6,7 8
a n
n e a F a O t
Instantaneous Central priority contact mode Last command priority Timer operation is accepted by remote controller Constant contact mode
9 2,10-19 0,1,3,5-7 4 8 9
e F a O t
×
× ×
× ×
×
×
× ×
×
×
*
*
*
×
*
*
*
× ×
×
× ×
× ×
×
×
×
× ×
×
×
×
×
×
×
×
×
×
× ×
* *
Forced stop *Only during timer operation
×
×
×
The remote controller permission / prohibition settings using the Ve-up controller are as follows. : permitted; × : prohibited
1 2 3 4
1 2 3
1 2 3 4
1 2 3 4
1 2 3 4
0 4 1 2 3 4
6— 1 2 3
1 2 1 2 3 4
0 5 1 2 3 4
7— 1 2 3
1 1
1 3 1 2 3 4
0 6 1 2 3 4
8—
1 4 1 2 3 4
0 7
1 5
NOTE also that a separate timer power source is needed when using the schedule timer independently independently.. Power source specs: DC 16V, +10%, -15%, 200mA. Recommended power source: Omron S82J-01015A. (Should be used with the output voltage adjusted to the center, DC 16V.) (3) Settings when recovering from a power outage (SW2-4) This selects whether to restart operation when the power comes back on after a power outage occurred during operation. This setting is given priority in cases where the indoor unit has an auto start ON / OFF jumper. Note also that regardless of whether switch SW2-4 is on or off, the operating mode, set temperature, fan direction and speed settings, and remote control prohibition status are stored. SW2-4 setting OFF (Factory setting)
×
×
×
×
permitted permitted prohibited Only OFF prohibited permitted/prohibited control is accepted permitted permitted prohibited prohibited permitted/prohibited permitted permitted/prohibited Last command prohibited permitted/prohibited permitted permitted/prohibited priority prohibited permitted/prohibited Does not affect settings
×
×
×
×
×
×
×
×
×
Constant contact mode
Instantaneous contact mode Constant contact mode Forced stop
OFF ON
What Happens
×
× × ×
× ×
×
KRP928B2S
Power supply for relay (DC 12V)
MC S5
M1 M2
Control mode
Operating control panel (Field supply)
(+) (–) (–)
MR1 MR1 MR2
The central controller can be combined with the following devices. devices.
(Matsushita Electric HC Relay, Omron MY Relay) Wiring length Max: 100m
r e l l o r t n o c F F O / N O
r e m i t e l u d e h c S
S t u P p I n B - i t D c a t n o c p o t s d e c r o F
t u p n i t c a t n o c t n a t s n o C
t u p n i t c a t n o c s u o e n a t n a t s n I
Central Remote Controller
ON / OFF controller
Schedule timer
×
×
D-BIPS
×
×
Forced stop contact input
r e l l o r t n o C e t o m e R d e r i W
r e l l o r t n o C e t o m e R s s e l e r i W
×
×
×
×
×
×
×
×
×
×
Wired Remote Controller
×
×
Wireless Remote Controller
×
are prohibited.
Run / stop Input Constant contact input Contact specs No-voltage minute electric current contact Instantaneous Instantane ous c ontact input (Minimum applicable load DC 12V, 1mA or lower) HA JEM-A-compatible equipment
Total wire length max: 100m
Coil resistance: 160 Ω ± 10%
r e l l o r t n o C e t o m e R l a r t n e C
Contact - Open to close: air condition stops During a forced stop, all
KRP928B2S
Power source for display
Operating Display
7.Combining Equipment
Invalid (forced stop). Close to open: no change in remote controller actions operating status.
Relay specs (MR1 and MR2) Coil voltage: DC 12V
Abnormalitydisplay
MR2
Last command priority
100 msec or more. Contact - Open to close: air condition runs. ON / OFF control is rejected (operate / stop / timer prohibition) Close to open: air conditioner is stopped (NOTE 1). (NOTE 2).
NOTE1: Since central equipment and HA JEM-A-compat JEM-A-compatible ible equipment both use last command priority, the contact status and operating status of the air conditioner might not match sometimes. Example: If the unit is run from the central controller while the air conditioner is stopped with an open contact, the contact will be open and the unit will be running. NOTE2: Operating Operating mode and fan direction and speed settings can be changed.
CB
The Operating / error signals can be read fr om the contact output (S5). Output specs M1: Turn MR 1 ON when the air conditioner is running. M2: Turn MR 2 when a communication error has occurred between the KRP928B2S and the air conditioner, or MR 1 is ON and the unit has stopped after an error. MR 2 is not turned ON during a warning.
The operating status of the air conditioner
S1
6.Read Operating / Error Display Signal
S8
OFF is reversed by an instantaneous input of
CA
× × × ×
Stops after recovering from a power outage
S1 SW3-1 SW3-2 operating mode setting setting
ON
Operating mode Fan direction temperature and fan speed
×
Instantaneous contact mode
Operations from centralcontroller, contact input and HA JEM-A input
What Happens
(4) Contact input function settings (SW3-1 to SW3-2) When using contact input (S1), choose one of the following functions.
Constant contact input
Stop
Instantaneous contact mode ON / OFF permitted permitted/prohibited control is • Constant rejected prohibited permitted/prohibited contact mode
Stops if the unit was stopped before the power outage and runs if it was running.
ON
Operations from the remote controller
Start / stop Change operating Change set Run / timer mode temperature
1 0
0 3
5— 1 2 3
0 9
Ve-up controller settings
S1 pin operatingmode
1 2 3 4
0 2
4—
Forced stop or remote controller permission input
Control mode
Operations from the remote controller Operations from “Run” control from the “Stop” control from the central controller, central controller central controller contact input and r d HA JEM-A input e e d r e p e p d d e n o o e n o o t o e o e i m t m t i e i e i t p S m r S m r t p t t u c s / u c s / g t g t n a e n a e r n r n n i i n t r i t r i a a u d f a e a e u d f r r R e p n d R e p n d p m p m
0 1 2 3
Instantaneous contact input (factory setting)
S1 operating mode
“Automatic” operation is not available from the central controller. When using “automatic” operation using the wireless remote controller, the central controller displays automatic cooling (heating) and 25°C. Even if the temperature is changed, it will return to 25°C after a while.
(2) Group number settings (SW1 and SW2-1 to SW2-3) Set these when using the central controller. (Set to the than one unit to the same number.
1 1 2 3
When using a central remote controller, the operating codes can be used to limit operation from wireless remote controllers. : permitted; × : prohibited
t n e m p i u q e e l b i t a p m o c A M E J A H
3P157704-2B
76
Room Air Conditioners E-Series
ED04-805
Optional Accessories
14.2 14.2.3 .3 KPW KPW937A 937A4 4
Before Installation Checking the parts
Check the following parts Name
Louver
Installation manual
Shape
Quantity
With 4 screws 1piece
1piece
Installation Procedure Selection of Installation Location Use when installing in a location that meets the following conditions. When installing near the border to a neighbor's house If exhaust blows directly on passers-by because outdoor unit is installed facing a road. Changing the fan direction of the outdoor unit to prevent it blowing directly on shrubbery, etc.
Installation of Louver is possible in the four directions: upward, downward, rightward, and leftward. The installation screws are attached to the louver. First temporarily attach the louver with 4 screws, then check that the angle is correct, and finally tighten the screws fully.
Prepared hole pitch 435mm Fan partition Part A (see figure below)
Installation
CAUTION 1.Install so that a short circuit is prevented. 2.For the use in snowy regions, avoid installation with the air outlet facing upward. Install so that the air outlet faces leftward, rightward, or downward. Snow accumulates in the air outlet of the outdoor unit, causing malfunction of the main body of the outdoor unit. 3.Be advised that if the fan direction is up, dead leaves and other foreign matter easily accumulates in the exhaust vent.
Prepared hole pitch 435mm Fan partition
The prepared hole is in between the grating of the grille. Part A (prepared hole) cross section (the shape of either a or b)
a) Grille grating
Prepared hole
b) Grille grating
Prepared hole
4P104499-1A
Room Air Conditioners E-Series
77
Specifications, designs and other content appearing in this brochure are current as of February 2008 but subject to change without notice.
ED 04-805 Printed in Japan 02/2008 B AK