PVC INSULATED CABLES
Need Power Connections? We Have The Solutions!
54
TABLE
55
DESCRIPTION
SPECIFICATION
1
Single-Core 450/750V PVC-Insulated, Non-Sheathed General Purpose Cables
MS 136 / BS 6004 / IEC 60502-1
2A
SINGLE-CORE 300/500V UNARMOURED CABLES wITH CIRCULAR Copper Conductors
MS 136 / BS 6004 / IEC 60502-1
2B
Single-Core 600/1000V Unarmoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
2C
Single-Core 600/1000V Armoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
3A
Two-Core 300/500V Unarmoured Cables with Circular Copper Conductors
MS 136 / BS 6004 / IEC 60502-1
3B
Two-Core 600/1000v Unarmoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
3C
Two-Core 600/1000C Armoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
4A
Three-Core 300/500V Unarmoured Cables with Circular Copper Conductors
MS 136 / BS 6004 / IEC 60502-1
4B
Three-Core 600/1000V Unarmoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
4C
Three-Core 600/1000v Armoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
5A
Four-Core 300/500V Unarmoured Cables with Circular Copper Conductors
MS 136 / BS 6004 / IEC 60502-1
5B
Four-Core 600/1000V Unarmoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
5C
Four-Core 600/1000V Armoured Cables with Circular Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
6A
Multi-Core 600/1000V Auxiliary Cables with Solid Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
6B
Multi-Core 600/1000V Auxiliary Cables with Stranded Copper Conductors
MS 274 / BS 6346 / IEC 60502-1
A
Sustained Current Rating And Voltage Drop For Single-Core Pvc-Insulated Cables with Copper Conductors
B
Sustained Current Rating And Voltage Drop For Two-core Pvc-Insulated Cables with Copper Conductors
C
Sustained Current Rating And Voltage Drop For Three-core And Four-Core PVC-insulated Cables with Copper Conductors
D
Sustained Current Rating And Voltage Drop For Auxiliary/ Multi-Core PVC-Insulated Cables with Copper Conductors
E
Electrical Characteristics Of PVC-Insulated Cables with Copper Conductors
F
Minimum Installation Radius Of PVC-Insulated Cables with Copper Conductors
PVC PV C INSULA I NSULATED TED CABLES LOW VOLTAGE SINGLE-CORE PVC-INSULATED POWER CABLES
LOW VOLTAGE SINGLE CORE PVC-INSULATED POWER CABLES TABLE 2B
SINGLE-CORE 600/1000V UNARMOURED CABLES WITH CIRCULAR COPPER CONDUCTORS
CONDUCTOR Thickness Thickness Overall Max. Conductor Min. Insulation Approx. Nom. Area No. & Dia. of Wire of Insulation of Sheath Diameter Resistance at 20°C Resistance at 20°C Weight mm mm sq.mm No./mm mm Ω/km MΩ.km kg/km 50 19/1.78 1.4 1.4 15.1 0.387 5 592 70 1.4 1.4 16.9 0.268 5 808 19/2.14 95 1.6 1.5 19.4 0.193 5 1100 37/1.78 120 1.6 1.5 21.0 0.153 5 1353 37/2.03 150 1.8 1.6 23.2 0.124 5 1658 37/2.25 185 2.0 1.7 25.8 0.0991 5 2065 37/2.52 240 2.2 1.8 29.0 0.0754 5 2681 61/2.25 300 2.4 1.9 32.1 0.0601 5 3335 61/2.52 400 2.6 2.0 35.8 0.0470 5 4219 61/2.85 500 2.8 2.1 39.6 0.0366 5 5268 61/3.20 630 2.8 2.2 43.8 0.0283 5 6681 127/2.52 800 2.8 2.3 48.3 0.0221 5 8413 127/2.85 1000 3.0 2.5 53.7 0.0176 5 10545 127/3.20 Colours for core identification : red or black Black or white sheath
MS 274 BS 6346 IEC 60502-1
LOW VOLTAGE SINGLE CORE PVC-INSULATED POWER CABLES TABLE 2C SINGLE-CORE 600/1000V 600/1000V ARMOURED CABLES WITH CIRCULAR COPPER CONDUCTORS CONDUCTOR Nom. Area
Colours for core identification : red or black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately 0.8mm) need not be checked by measurement.
Colours for core identification : red and black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately 0.8mm) need not be checked by measurement.
Colours for core identification : red, yellow and blue Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately 0.8mm) need not be checked by measurement.
Colours for core identification : red, yellow, blue and black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately 0.8mm) need not be checked by measurement.
64
MS 274 BS 6346 IEC 60502-1
LOW VOLTAGE MULTI CORE PVC-INSULATED POWER CABLES TABLE 6A
MULTI-CORE 600/1000V AUXILIARY CABLES WITH SOLID COPPER CONDUCTORS
CONDUCTOR No of Thickness **Thickness Nominal armour Thickness Overall Max. Conductor Min. Insulation cores Nom. Area No. & Dia. of Wire of Insulation of bedding wire diameter of Sheath Diameter Resistance at 20°C Resistance at 20°C
LOW VOLTAGE MULTI CORE PVC-INSULATED POWER CABLES TABLE 6B
MULTI-CORE 600/1000V AUXILIARY CABLES WITH SOLID COPPER CONDUCTORS
CONDUCTOR Thickness **Thickness Nominal armour Thickness Overall Max. Conductor Min. Insulation No of cores Nom. Area No. & Dia. of Wire of Insulation of bedding wire diameter of Sheath Diameter Resistance at 20°C Resistance at 20°C
Colours for core identification : white insulation with printed black numbering Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately 0.8mm) need not be checked by measurement.
65
MS 136/MS 274 BS 6004/BS 6346 IEC 60502-1
SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE A SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR SINGLE-CORE PVC INSULATED CABLES WITH COPPER CONDUCTORS Unarmoured Cables Current Rating
SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE B SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR TWO-CORE PVC INSULATED CABLES WITH COPPER CONDUCTORS CONDUCTOR Nom. Area