PROCEDURE FOR BTS-240XL-II COMMISSIONING under BR9.0 --July 21, 2008 Start Programs LMT291_1_18_02 Start LMT LMT Control Center window will appear Wait for LOGON to become dark blue Click on logon Enter the Username: SAG Enter Password: SAG Connect and close
Author: Anjit Rajkarnikar
Click on Input handler 1. Download Software Managed Element Software Management Double click on Software management DNLALL.EXE SRCPATH---c:\SW\BTSPLUS\HS011818.SWL (Command viewer: Dnlall.exe window will appear) Overwrite yes (It will take 10 mins.) and after completion of download 2. Software Activation Managed element BSS functional BTSM (Double click) Activate BTSM BTSM: 0 FileID: HS011818.SWL (copy from relnotes.txt and paste) FileSWV: 01-04-18-01-18-07_08-04-03 (copy from relnotes.txt and paste) After giving activate SW BTS will ask for login again. BTS will be in phase2 3. Creation as per Configuration BTSEP Double click on Rack Set Rack Vendna: NSN / TypRack: BS240XL and Submit BPORT CREATE BPORT NAME: BPORT: 0 / L1PT: PCM30 CRC4 / LCONF: STAR/MULTI/ LOOP (as instructed) BER : LOWER: E10_6 / UPPER: E10-3 ; L1RAT= Protocol signalling LAPDLE CREATE LAPDLE NAME: LAPDLE: 0 (signaling cut off 32 channels) / LAPDCH: BPORT: BPORT0 TSL: 31 (Depending on SITE LINKAGE, 30 for Multidrop) / SSL: FULL_64KB BTSE SETBTSEP SALUNAM: NE346… (Shelf unique name as given in the BTS paper) For identification of the site in BSC. Vendname: NSN BTSM SETBTSM TEI: 0 (Limited up to 63) Create COSA FCUMAIN CREATE FCUMAIN (As equipped) Eg: CREATE FCUMAIN [BASICS]: NAME:FUCMAIN:0&&11 FCUMODE: doubleCUMode (Create FCU:1,3,4,5,6,7.After which lock and delete CUs which are not present asFCUs:0,2,8,9,10,11 in our config.) FCUTR CREATE FCUTR [BASICS] NAME: FCUTR: 0&&23 (Create FCUTR as: 2*FCU, 2*FCU+1 or delete those from 24 FCUTRs if not required) DUVSWR CREATE DUVSWR (as equipped) Creation of BTS-240XL -II with 4:2 combiners CREATE DUVSWR: NAME=DUVSWR: 0 CELL NO=0 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN4TX0 FCUMAIN5TX0 (Depending on the cable connections of CUs to DUAMCO) CREATE DUVSWR: NAME= DUVSWR: 1 CELL NO=0 COMBMD=FourToTwo, WDDUVSWR= FCUMAIN4TX1 FCUMAIN5TX1 CREATE DUVSWR: NAME=DUVSWR: 10 CELL NO=1 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN3TX0 FCUMAIN1TX0 CREATE DUVSWR: NAME=DUVSWR: 11 CELL NO=1 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN3TX1 FCUMAIN1TX1 CREATE DUVSWR: NAME=DUVSWR: 4 CELL NO=2 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN6TX0 FCUMAIN7TX0 CREATE DUVSWR: NAME=DUVSWR: 5 CELL NO=2 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN6TX1 FCUMAIN7TX1 DULNA CREATE DULNA (as equipped) CREATE DULNA: NAME=DULNA: 0 CELL NO=0 COMBMD=FourToTwo, WDLNA=FCUMAIN4N FCUMAIN4N1 FCUMAIN5N FCUMAIN5N1 CREATE DULNA: NAME=DULNA: 1 CELL NO=0 COMBMD=FourToTwo, WDLNA= FCUMAIN4D FCUMAIN4D1 FCUMAIN5D FCUMAIN5D1
CREATE DULNA: NAME=DULNA:10 CELL NO=1 COMBMD=FourToTwo, WDLNA= FCUMAIN1N FCUMAIN1N1 FCUMAIN3N FCUMAIN3N1 CREATE DULNA: NAME=DULNA: 11 CELL NO=1 COMBMD=FourToTwo, WDLNA= FCUMAIN1D FCUMAIN1D1 FCUMAIN3D FCUMAIN3D1 CREATE DULNA: NAME=DULNA: 4 CELL NO=2 COMBMD=FourToTwo, WDLNA= FCUMAIN6N FCUMAIN6N1 FCUMAIN7N FCUMAIN7N1 CREATE DULNA: NAME=DULNA: 5 CELL NO=2 COMBMD=FourToTwo, WDLNA FCUMAIN6D FCUMAIN6D1 FCUMAIN7D FCUMAIN7D1
FANP CREATE FANP (0TO 5 FOR BS240 AND 0 TO 7 FOR BS240XL) For example: CREATE FAN: NAME=RACK: 0/FAN: 0&&7; Creation of external alarm ENVABTSE For Example: CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 2, INTINF=low, ASEV=CRITICAL, ASTRING= “MAINS FAILURE”; CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 3, INTINF=low, ASEV=MAJOR, ASTRING= “DC RECTIFIER FAIL”; CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 4, INTINF=HIGH, ASEV=MAJOR, ASTRING= “TEMPERATURE”; INTEGRATION Managed element BSS functional Double click on BTSM set BTSM: ABISLKSA: Terrestrial connection, TEI: 0 Managed element BSS functional Double click on BTSM CONNBSC Now Login again, BTS should be PH3 Set SW load safety HS011692.SWL: 01-04-16-01-87-00_04-09-09
Get BTSM unlocked.
Color Combination of PCM Cable for BTS ===============================================
Tx:
5 PURPLE
Rx:
WHITE BLUE
4 GREEN
3 gnd
2 Gnd
1 gnd
In DDF Blue - White (RX)
|| Green - Purple (Tx)
===================================================== In BTS –BPORT
Green | Purple (Tx)
Green
purple
Blue
Orange
White
| White (RX)
In Multidrop COnfig of BTS: Cretae BPORT0 & BPORT1 in the Master BTS(Say BTS900) Bport 0---TSL 31 Bport 1--TSL 30
Note: Module OVPT is the interface module between the BSC and the BTSE (for the outdoor versions in common with WAVEs,NTs or CSUs). Therefore, if a failure of the Abis link is reported, the OVPT must be considered.! When the OVPT fails, the PCM-line is also broken also for all subsequent BTSE, in the event of a multidrop configuration.
Alarm Creation in BTS: ENVABTSE: 2Mains failure ENVABTSE: 3 rectifier ENVABTSE: 4temperature