To Size the required ampere hour capacity of the battery and current rating of battery charger in large substations.Full description
Industrial battery sizing calculation sheet with all formulas and proceduresFull description
sdk
Full description
Design basis consideration for Battery sizing a document by TCE.Full description
UPS,Battery,InverterFull description
This can be referred
Reactor sizingFull description
HVAC Air Heat Air Flow CalculationsFull description
hoFull description
Full description
Battery and Charger Sizing Calculation IEEE 485Full description
hoDescripción completa
Full description
Cable sizing calculation sheet with formulaFull description
Full description
Full description
Battery sizing calculationsFull description
The Batteries form a significant part of many electronic devices. Typical electrochemical batteries or cells convert chemical energy into electrical energy. Batteries based on the charging ability are classified into primary and secondary cells. Seco
7
ANNEXURE - IV (CELL CAPACITY RATING FACTOR CALCULATION SHEET)
Cell Type: KPL970P Amco make End Cell Voltage 1.14V/Cell
2. For discharge data refer Annexure - V 'Cell Performance Data" as given by battery manufacturer.
Basic Data : Lowest Electrolytic Temperature = 18˚C Minimum end Cell Voltage = 1.13V End Cell Voltage during Equalisation Charging = 1.42V Minimum System Voltage, Umin = 193V Maximum System Voltage, Umax = 242V Number of cell per battery bank = 171 (refer clause 4.3.1) (1) Period
(2) Load (ampere)
(3) Change in load (ampere)
(4) (5) (6) (7) (8) Duration of Time to end of Capacity Temperature Required Section Size Period (minute) Section rating factor for Derating Factor for (3) x (6) x (7) = Rated Amp (minute) t Min Rate (Kt) t Min (Tt) hour
Section 1 - First Period Only 1 307
307
1
1
Section 2 - Period-1 & 2 1 307 2 247
307 -60
1 29
Section 3 - Period-1, 2 & 3 1 307 2 247 3 56
307 -60 -191
Random Equipment Load 1 0
0
Maximum Section Size Ah Random Load Size Ah Design margin Uncorrected size in Ah
= = = =
668 0 1.05 668
Aging Factor
=
1.25
Required Capacity in Ah =
876
0.79 Sec-1 Total
1
242 242
-
30 29
1.59 1.57 Sec-2 Sub Total Total
1 1
488 488 394
-94 -94
1 29 570
600 599 570
10.24 10.23 9.75 Sec-3 Sub Total Total
1 1 1
3145 3145 668
-614 -1863 -2477
0
0
0.00
1 -
-
Temperature
KBL
1 Sec.
5 Sec.
30 Sec
1 Min.
5 Min.
10 Min. 15 Min. 20 Min. 30 Min.
1 Hr.
1.5 Hrs.
15 deg.C
0.940
0.941
0.943
0.950
0.950
0.950
0.950
0.950
0.952
0.960
0.970
12 deg.C
0.840
0.839
0.838
0.842
0.847
0.867
0.872
0.875
0.882
0.902
0.920
10 deg.C
0.880
0.880
0.880
0.885
0.888
0.900
0.903
0.905
0.910
0.925
0.940
5 deg.C
0.815
0.816
0.820
0.828
0.833
0.835
0.839
0.843
0.850
0.868
0.885
0 deg.C
0.752
0.752
0.760
0.762
0.765
0.775
0.781
0.787
0.800
0.820
0.830
-5 deg.C
0.680
0.681
0.686
0.700
0.700
0.705
0.709
0.713
0.725
0.752
0.765
-10 deg.C
0.630
0.630
0.630
0.630
0.630
0.640
0.643
0.645
0.650
0.680
0.700
2 Hrs.
3 Hrs.
4 Hrs.
5 Hrs.
6 Hrs.
7 Hrs.
8 Hrs.
9 Hrs.
10 Hrs.
0.980
0.990
0.995
0.995
1.000
1.000
1.000
1.000
1.000
0.930
0.940
0.953
0.953
0.958
0.958
0.958
0.958
0.958
0.950
0.960
0.970
0.970
0.975
0.975
0.975
0.975
0.975
0.900
0.915
0.925
0.930
0.938
0.938
0.938
0.938
0.938
0.850
0.870
0.880
0.893
0.900
0.900
0.900
0.900
0.900
0.788
0.815
0.830
0.847
0.850
0.850
0.850
0.855
0.860
0.725
0.760
0.780
0.800
0.800
0.800
0.800
0.810
0.820
7
ANNEXURE - IV (CELL CAPACITY RATING FACTOR CALCULATION SHEET)