ANTENNA & SUBSYSTEM Product Catalogue 2016
Legal Disclaimer Comba Telecom Ltd retains copyright on all the text, graphics and trademarks displayed on this paper. All the text, graphics and trademarks displayed on this paper are owned by Comba Telecom Ltd and used under licence by Comba affiliates. You may print copies of the information on this paper and store the files on your computer for your personal use. You may not distribute text or graphics to others without the express written consent of Comba Telecom Ltd and Comba affiliates. Also, you may not, without our permission, copy and distribute this information on any other server, or modify or reuse text or graphics on this or any other system. No reproduction of any part of the paper may be sold or distributed for commercial gain, nor shall it be modified or incorporated in any other work, publication or site, whether in hardcopy or electronic format, including postings to any other site. Comba Telecom Ltd reserves all other rights. The information on this paper had been included in good faith and is for general purposes only. It should not be realised upon for any specific purpose and no representation or warranty is given as regards to its accuracy or completeness. No Information on this paper shall constitute an invitation to invest in Comba Telecom Ltd or any of its affiliates. Neither Comba Telecom Ltd and Comba affiliates, nor their or their affiliates' officers, employees or agents shall be liable for any loss, damages or expenses arising out of any access to or use of this paper or any site linked to it, including, without limitation, any loss of profit, indirect, incidental or consequential loss.
About Us Comba Telecom is a leading supplier of infrastructure and wireless enhancement solutions to mobile operators and enterprises to enhance and extend their wireless communications networks. Established in 1997, and listed on the Hong Kong Stock Exchange in 2003, it has grown to become a global supplier with its extensive distribution network and 60+ offices globally.
With seasoned team of research and development engineers and its state-of-the-art design tools and testing equipment, Comba is able to provide its innovative patented designs and yet cost-effective products to the customers. It has a largest far field microwave anechoic chamber in the region. With the complimentary of SATIMO 128 probes of near field testing range, it can provide fast and accurate testing results to verify and ensure the product design. Comba test ranges have been used by many customers around the world as accredited testing facilities for antenna performance benchmarking. Comba Antenna & Subsystem Business Unit offers full range of wireless antenna and RF conditioning products for cellular systems, which include: Base Station Antenna Indoor Antenna Remote Electrical Tilt System RF Conditioning Products Comba is committed to quality consistency and environmental protection and is ISO9001 and ISO14001 certified. With its highly efficiency production lines in China and strict process control system, Comba’s manufacturing facility is able to deliver high volume products with consistent quality.
Comba Manufacturing Facility in Guangzhou, China
Comba R&D Centre in Guangzhou, China
Antenna Naming Convention
ODV2 - 065R18Jxx-G Radome Material Pre-configured Tilt (°) Frequency Band Gain (dBi) Polarization Horizontal Beamwidth (°) Categories Antenna type Environment Class
Antenna type
Variable Electrical Downtilt
Radome Material
OA
Omni-directional
P
FET Antenna
G
Fiberglass
DP
Directional panel FET antenna
V
VET Antenna
-
UV Resistant PVC
DV
Directional panel VET antenna
DI
RCU built-in VET antenna
DS
Directional smart antenna
2
Two Same Frequency Band
R
Cross polarization
DR
Smart bias tee built-in VET antenna
3
Three Same Frequency Band
V
Vertical polarization
Categories
Polarization
VH
Environment Class
Frequency Band Abbreviation A
820~896 MHz
I
Indoor
B C D
806~960 MHz 1710~1880 MHz 2490-2700 MHz
O
Outdoor
E
790-960 MHz
F
1920~2170 MHz
G
880~960 MHz
J
1710~2690 MHz
K
1710~2170 MHz
L
2300~2690 MHz
M
P
698-960 MHz 806~960, 1710~2500 MHz(Indoor) 698-862 MHz(Base Station Antenna) 1850~1990 MHz
T
790~960, 1710~2700 MHz
U
600-960, 1710-4000 MHz
N
Vertical and Horizontal polarization
Page 3 of 139
Combiner Naming Convention
CM – FDWY4D-ODx DC By-pass Type Connector Type Environmental Class Double Units Input Ports No. of Combiner Frequency Band Product Type
A B C D E F G H I K
Frequency Band L 698-894 P 806~960 R 824~894 1710~1880 T 880~960 380-960 U 890~960 W 698-3800 Y 806-1880 Z 1710~2170
2400-2500 1850-1990 698-2700 1880-1920 2010-2025 2300-2400 >3000 1920-2170 2300-2700 47-2700
x S
DC By-pass Type 1: No DC Path 2,3,…,8: DC path at Low Band/High Band DC Autosense
Environmental Class O Outdoor I Indoor
Product Type CM
Combiner
D N S
Connector Type DIN Connector N Connector SMA Connector
Page 4 of 139
Passive Component Naming Convention
DC – R06 – OD500C(H) PIM Level Design Technique Power Handling Connector Type Environmental Class Coupling Value / Splitting Way Frequency Band Product Type
A B C D E F G H I K
Frequency Band L 698-894 P 806~960 R 824~894 1710~1880 T 880~960 380-960 U 890~960 W 698-3800 Y 806-1880 Z 1710~2170
2400-2500 1850-1990 698-2700 1880-1920 2010-2025 2300-2400 >3000 1920-2170 2300-2690 47-2700
DC CO PS HC FP
Product Type Direction Coupler Coupler Power Splitter Hybrid Coupler Filter
M C L
Design Technique Microstrip Coaxial Cavity Stripline
Environmental Class O Outdoor I Indoor Connector Type D DIN Connector N N Connector
(H) (XH)
PIM Level -150dBc -153dBc
Page 5 of 139
Base Station Antenna ........................................................ 7 Indoor Antenna................................................................. 76 RET System ...................................................................... 84 RF Product ........................................................................ 90
Page 6 of 139
Base Station Antenna
Page 7 of 139
Base Station Antenna Multiple-beam Antenna .................................................................................................................................................................................. 11 XX-Pol ODDV-032R20K-G............................................................................................................................................................................... 12
XXX-Pol ODTP-024R20K06-G ........................................................................................................................................................................... 13
V-Pol & X-Pol Antenna ................................................................................................................................................................................... 14 V-Pol ODP-065V11N ..................................................................................................................................................................................... 15
698-960MHz ODV-065R15M-G................................................................................................................................................................................. 16 ODV-065R16M-G................................................................................................................................................................................. 17
790-960MHz ODV-032R18E-G ................................................................................................................................................................................. 18 ODV-032R20E-G V1 ............................................................................................................................................................................ 19 ODV-065R15E-G ................................................................................................................................................................................. 20 ODV-065R17E-G ................................................................................................................................................................................. 21 ODV-065R18E ..................................................................................................................................................................................... 22 ODV-090R17E-G ................................................................................................................................................................................. 23
1710-2170MHz ODV-032R21K-G ................................................................................................................................................................................. 24 ODV-032R23K-G V1 ............................................................................................................................................................................ 25 ODV-065R15K-G ................................................................................................................................................................................. 26 ODV-065R18K-G V1 ............................................................................................................................................................................ 27 ODV-065R21K-G ................................................................................................................................................................................. 28 ODV-090R17K-G ................................................................................................................................................................................. 29
1710-2690MHz ODV-065R18J-G .................................................................................................................................................................................. 30
Page 8 of 139
XX-Pol Antenna .............................................................................................................................................................................................. 31 698-960MHz/1710-2690MHz ODP-065R12M14J-G ........................................................................................................................................................................... 32 ODV-065R14M17J-G ........................................................................................................................................................................... 33 ODV-065R15M18J-G ........................................................................................................................................................................... 34 ODV-065R16M18J-G ........................................................................................................................................................................... 35
806-960MHz/1710-2690MHz ODP-065R09BJ-G ............................................................................................................................................................................... 36 ODP-065R09BJ-G(2J) ......................................................................................................................................................................... 37
790-960MHz/1710-2170MHz ODV-065R15E18K-G V2...................................................................................................................................................................... 38 ODV-065R17E18K-G V1...................................................................................................................................................................... 39 ODV-065R18EK-G ............................................................................................................................................................................... 40
790-960MHz/1710-2690MHz ODV-065R17E18J-G............................................................................................................................................................................ 41 ODV-065R18EJ-G ............................................................................................................................................................................... 42
790-960MHz/790-960MHz ODV2-065R17E-G ............................................................................................................................................................................... 43
1710-2170MHz/1710-2170MHz ODV2-065R18K-G V2 .......................................................................................................................................................................... 44 ODV2-065R21K-G V1 .......................................................................................................................................................................... 45
1710-2690MHz/1710-2690MHz ODV2-065R16J-G ................................................................................................................................................................................ 46 ODV2-065R18J-G V1........................................................................................................................................................................... 47
XXX-Pol Antenna ............................................................................................................................................................................................ 48 698-960MHz/1710-2690MHz/1710-2690MHz ODP-065R12M14JJ-G ......................................................................................................................................................................... 49 ODV-065R14M17JJ-G ......................................................................................................................................................................... 50 ODV-065R15M18JJ-G ......................................................................................................................................................................... 51 ODV-065R16M18JJ-G ......................................................................................................................................................................... 52 ODV-065R17M18JJ-G ......................................................................................................................................................................... 53
790-960MHz/1710-2170MHz/1710-2170MHz ODV-065R15EKK ................................................................................................................................................................................ 54 ODV-065R15E18KK-G V2 ................................................................................................................................................................... 55 ODV-065R17E18KK-G V1 ................................................................................................................................................................... 56 ODV-065R18EKK-G ............................................................................................................................................................................ 57
790-960MHz/1710-2690MHz/1710-2690MHz ODV-065R15EJJ.................................................................................................................................................................................. 58 ODV-065R17EJJ-G.............................................................................................................................................................................. 59 ODV-065R18EJJ-G.............................................................................................................................................................................. 60
Page 9 of 139
1710-2170MHz/1710-2170MHz/1710-2170MHz ODV3-065R18K-G V1 .......................................................................................................................................................................... 61
1710-2690MHz/1710-2690MHz/1710-2690MHz ODI3-065R15J-G ................................................................................................................................................................................. 62 ODV3-065R18J-G V1........................................................................................................................................................................... 63
XXXX-Pol Antenna .......................................................................................................................................................................................... 64
698-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz ODV-065R17M18JJJ-G ....................................................................................................................................................................... 65
698-862MHz/880-960MHz/1710-2690MHz/1710-2690MHz ODI-065R15NG18JJ-G ........................................................................................................................................................................ 66
790-960MHz/1710-2170MHz/1710-2690MHz/1710-2690MHz ODI-065R12E15KJJ-G ......................................................................................................................................................................... 67 ODI-065R15E18KJJ-G ......................................................................................................................................................................... 68 ODV-065R17EKJJ-G ........................................................................................................................................................................... 69
790-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz ODV-065R17E18JJJ-G ........................................................................................................................................................................ 70
790-960MHz/790-960MHz/1710-2690MHz/1710-2690MHz ODV2-065R17E18J-G.......................................................................................................................................................................... 71
XXXXX-Pol Antenna ........................................................................................................................................................................................ 72 698-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz ODV-065R17M18JJJJ-G...................................................................................................................................................................... 73
698-806MHz/824-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz ODI-065R16NB17JJJ-G ....................................................................................................................................................................... 74
790-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz ODV-065R17E18JJJJ-G ...................................................................................................................................................................... 75
Page 10 of 139
Multiple-beam Antenna Model
Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Length (mm)
ODDV-032R20K-G
XX-Pol
1710-2170 / 1710-2170
19.9 / 19.9
32
0-10 / 0-10
1340
ODTP-024R20K06-G
XXX-Pol
1710-2170 / 1710-2170 / 1710-2170
20.1 / 20.1 / 20.1
24
6/6/6
840
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0216
Page 11 of 139
Outdoor Directional Twin-beam Antenna ODDV-032R20K-G XX Pol, 32° 1710-2170/1710-2170MHz 19.9/19.9dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beam Centers (°) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
1850-1990 45° 19.5 -28°,+28° 33 6.9 0-10 / 0-10 ≥19(0°) ≥17(5°) ≥15(10°) ≥25 ≥15 ≤1.5:1 ≥16 ≥28 <-150 300 50
19.2 -32°,+32° 36 7.2
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @boresight (dB) VSWR Beam Isolation (dB) Cross-polar Isolation (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 19.9 -27°,+27° 31 6.3
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1340x320x110 / 52.8x12.6x4.3 15.3 / 33.7 20.9 / 46.1 Fiberglass, Light Grey 00-ZJ10(16) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
582 / 89 / 676 1640x430x215 / 64.6x16.9x8.5 26.0 / 57.3 Direct Ground
* TIA-222-G
Connector Position
1710-2170 +45°
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0216
Page 12 of 139
Outdoor Directional Tri-beam Antenna ODTP-024R20K06-G XXX Pol, 24° 1710-2170/1710-2170/1710-2170MHz 20.1/20.1/20.1dBi, FET: 6/6/6
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beam Centers (°) Horizontal Beamwidth (°) Vertical Beamwidth (°) Fixed Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @boresight (dB) VSWR Beam Isolation (dB) Cross-polar Isolation (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2170 1850-1990 45° 19.4 -30°,0°,+30° 24 11.5 6/6/6 ≥16 ≥26 ≥15 ≤1.5:1 ≥16 ≥25 <-150 300 50
18.8 -33°,0°,+33° 26 12.0
1710-2170 1920-2170 20.1 -28°,0°,+28° 24 11.0
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 840x380x138 / 33.1x15.0x5.4 11.9 / 26.2 14.7 / 32.4 Fiberglass, Light Grey 00-ZJ15A(25) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200 345 / 67 / 411 19.8 / 43.7 1110x490x260 / 43.7x19.3x10.2 Direct Ground
* TIA-222-G
Connector Position
1710-2170 +45°
1710-2170 -45° 1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-0 / 0116
Page 13 of 139
V-Pol & X-Pol Antenna Model
Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Length (mm)
ODP-065V11N
V-Pol
698-960 / 1710-2700
10.6 / 11.0
65
-
610
ODV-065R15M-G
X-Pol
698-960
14.8
65
VET 0-14
1450
ODV-065R16M-G
X-Pol
698-960
15.8
65
VET 0-10
2000
ODV-032R18E-G
X-Pol
790-960
17.6
32
VET 0-20
1415
ODV-032R20E-G V1
X-Pol
790-960
19.2
32
VET 0-11
1970
ODV-065R15E-G
X-Pol
790-960
15.0
65
VET 0-16
1315
ODV-065R17E-G
X-Pol
790-960
16.6
65
VET 0-10
1975
ODV-065R18E
X-Pol
790-960
17.5
65
VET 0-12
2615
ODV-090R17E-G
X-Pol
790-960
16.5
90
VET 0-12
2615
ODV-032R21K-G
X-Pol
1710-2170
20.5
32
VET 0-10
1310
ODV-032R23K-G-V1
X-Pol
1710-2170
22.0
32
VET 0-8
1960
ODV-065R15K-G
X-Pol
1710-2170
15.0
65
VET 0-20
680
ODV-065R18K-G V1
X-Pol
1710-2170
17.8
65
VET 0-10
1335
ODV-065R21K-G
X-Pol
1710-2170
19.5
65
VET 0-8
1960
ODV-090R17K-G
X-Pol
1710-2170
16.3
90
VET 0-10
1310
ODV-065R18J-G
X-Pol
1710-2690
17.8
65
VET 0-12
1365
Page 14 of 139
Outdoor Directional Panel Antenna ODP-065V11N V Pol, 65° 698-960/1710-2700MHz 10.6/11.0dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-800
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Front-To-Back Ratio 180°30°(dB) VSWR IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2700 800-960
1710-2200
2200-2700
10.5 67 33
11.0 66 33
Vertical 10.5 70 30
10.6 67 28 ≥20 ≤1.5:1 <-153 100 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in)
Specifications
Weight, w/o Mounting Kit (kg) / (lb)
6.4 / 14.1
Weight, with Mounting Kit (kg) / (Ib)
9.3 / 20.5
Radome Material and Color Mounting Kit Connector Type and Location
Fiberglass, White 00-ZJ15A(32) 1 x 7/16 DIN-Female, Bottom
Operational Temperature (°C)
-50 to +70
Operational Humidity (%) Operational/Max Wind Speed (mi/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in)
Product Picture
610x320x145 / 24.0x12.6x5.7
≤95 93.2 / 124.3 180 / 50 / 225 890x430x260 / 28.5x16.9x10.2
Shipping Weight (kg) / (Ib) Lightning Protection
11.4 / 25.1 Direct Ground
* TIA-222-G
Connector Position
698-2700
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-1 / 0116
Page 15 of 139
Outdoor Directional Single-band Antenna ODV-065R15M-G X Pol, 65° 698-960MHz 14.8dBi, E-Tilt: 0-14
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-824
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
790-896 45° 14.4 65 13.8 0-14 ≥16(0°) ≥15(7°) ≥14(14°) ≥25 ≥17 1 ≤1.5:1 ≥30 <-150 500 50
14.0 69 15.4
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
880-960 14.8 61 12.6
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (lb) Lightning Protection
Specifications 1450x320x145 / 57.1x12.6x5.7 13.7 / 30.2 18.7 / 41.2 Fiberglass, Light Grey SJA-B-12R(17) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
506 / 126 / 641 1770x430x270 / 69.7x16.9x10.6 25.0 / 55.1 Direct Ground
* TIA-222-G
Connector Position
698-960 -45°
698-960 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-4 / 0116
Page 16 of 139
Outdoor Directional Single-band Antenna ODV-065R16M-G X Pol, 65° 698-960MHz 15.8dBi, E-Tilt: 0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-824
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
790-896 45° 15.7 64 9.6 0-10 ≥17(0°) ≥16(5°) ≥15(10°) ≥25 ≥17 1 ≤1.5:1 ≥30 <-150 500 50
15.2 68 10.8
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
880-960 15.8 61 8.9
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2000x320x145 / 78.7x12.6x5.7 17.0 / 37.5 23.3 / 51.4 Fiberglass, Light Grey 00-ZJ11(08) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
751 / 173 / 960 2340x430x270 / 92.1x16.9x10.6 31.0 / 68.4 Direct Ground
* TIA-222-G
Connector Position
698-960 -45°
DIN 7/16” F
698-960 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0815
Page 17 of 139
Outdoor Directional Single-band Antenna ODV-032R18E-G X Pol, 32° 790-960MHz 17.6dBi, E-Tilt: 0-20
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
17.0 34 15.0
17.6 32 13.9 0-20 ≥17(0°) ≥16(10°) ≥16(20°) ≥25 ≥17 1 2 ≤1.5:1 ≥30 <-150 500 50
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) Squint (°) VSWR Isolation between Ports(dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1415x500x140 / 55.7x19.7x5.5 28.0 / 61.7 34.3 / 75.6 Fiberglass, Light Grey 00-ZJ11(16) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
925 / 113 / 1118 1765x635x305 / 69.5x25.0x12.0 38.0 / 83.8 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-4 / 0116
Page 18 of 139
Outdoor Directional Single-band Antenna ODV-032R20E-G V1 X Pol, 32° 790-960MHz 19.2dBi, E-Tilt: 0-11
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
18.5 34 10.4 0-11 ≥18(0°) ≥17(6°) ≥16(11°) ≥15
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) Squint (°) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
19.2 32 9.5
≥25
≥28 ≥17 1 2 ≤1.5:1 ≥30 <-150 500 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1970x500x140 / 77.6x19.7x5.5 30.6 / 67.5 40.9 / 90.2 Fiberglass, Light Grey 00-ZJ11(12) (three mounting points) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1397 / 162 / 1735 2330x635x305 / 91.7x25.0x12.0 52.6 / 116.0 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
DIN 7/16” F
790-960 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0116
Page 19 of 139
Outdoor Directional Single-band Antenna ODV-065R15E-G X Pol, 65° 790-960MHz 15.0dBi, E-Tilt: 0-16
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
14.5 67 16.0
15.0 63 14.5 0-16 ≥18(0°) ≥16(8°) ≥16(16°) ≥25 ≥17 3 ≤1.5:1 ≥30 <-150 500 50
st
1 Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination@0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Connector Type and Location Mounting Kit Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1315x265x120 / 51.8x10.4x4.7 11.3 / 24.9 16.3 / 35.9 Fiberglass, Light Grey 2 x 7/16 DIN-Female, Bottom SJA-B-12R(16) -50 to +70 ≤95 150 / 200
Product Picture
376 / 96 / 444 1625x375x250 / 64.0x14.8x9.8 20.8 / 45.9 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-5 / 0116
Page 20 of 139
Outdoor Directional Single-band Antenna ODV-065R17E-G X Pol, 65° 790-960MHz 16.6dBi, E-Tilt: 0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
16.0 66 10.2
16.6 63 9.3 0-10 ≥17(0°) ≥16(5°) ≥16(10°) ≥15(typ.) ≥25 ≥20 2 ≤1.5:1 ≥30 <-150 500 50
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1975x265x120 / 77.8x10.4x4.7 17.0 / 37.5 22.6 / 49.8 Fiberglass, Light Grey 00-ZJ10(12) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
597 / 150 / 716 2285x375x250 / 90.0x14.8x9.8 26.0 / 57.3 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
DIN 7/16” F
790-960 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-3 / 0116
Page 21 of 139
Outdoor Directional Single-band Antenna ODV-065R18E X Pol, 65° 790-960MHz 17.5dBi, E-Tilt: 0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
17.0 67 7.7
17.5 64 7.2 0-12 ≥18(0°) ≥17(6°) ≥16(12°) ≥25 ≥17 2 ≤1.5:1 ≥30 <-150 500 50
st
1 Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2615x265x120 / 103.0x10.4x4.7 20.5 / 45.1 26.1 / 57.4 UV Resistant PVC, Light Grey 00-ZJ10(08) 2 x 7/16 DIN-Female, Bottom -40 to +60 ≤95 150 / 200
Product Picture
814 / 201 / 972 2915x375x250 / 114.8x14.8x9.8 34.0 / 75.0 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0116
Page 22 of 139
Outdoor Directional Single-band Antenna ODV-090R17E-G X Pol, 90° 790-960MHz 16.5dBi, E-Tilt: 0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960 790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
16.0 85 7.8
16.5 84 7.0 0-12 ≥18(0°) ≥16(6°) ≥16(12°) ≥14 ≥25 ≥17 1 ≤1.5:1 ≥30 <-150 500 50
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2615x265x145 / 103.0x10.4x5.7 24.3 / 53.6 29.9 / 65.9 Fiberglass, Light Grey 00-ZJ10(08) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
837 / 289 / 829 2915x375x275 / 114.8x14.8x10.8 37.2 / 82.0 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-3 / 0116
Page 23 of 139
Outdoor Directional Single-band Antenna ODV-032R21K-G X Pol, 32° 1710-2170MHz 20.5dBi, E-Tilt: 0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1850-1990 45° 20.2 30 6.6 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥27(typ.) ≥18 1 2 ≤1.5:1 ≥30 <-150 300 50
19.6 32 7.1
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) Squint (°) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 20.5 28 6.2
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1310x265x90 / 51.6x10.4x3.5 13.5 / 29.8 18.5 / 41.0 Fiberglass, Light Grey SJA-B-12R(16) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
397 / 67 / 537 1595x375x215 / 62.8x14.8x8.5 23.5 / 51.8 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0116
Page 24 of 139
Outdoor Directional Single-band Antenna ODV-032R23K-G V1 X Pol, 32° 1710-2170MHz 22.0dBi, E-Tilt: 0-8
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1850-1990 45° 21.6 31 4.6 0-8 ≥17(0°) ≥16(4°) ≥15(8°) ≥28(typ.) ≥17 2 1.5 ≤1.5:1 ≥30 <-150 300 50
21.2 33 5.0
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) Squint (°) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 22.0 30 4.4
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1960x265x90 / 77.2x10.4x3.5 15.1 / 33.3 20.7 / 45.6 Fiberglass, Light Grey 00-ZJ10(12) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
641 / 103 / 866 2245x375x215 / 88.4x14.8x8.5 25.5 / 56.2 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0116
Page 25 of 139
Outdoor Directional Single-band Antenna ODV-065R15K-G X Pol, 65° 1710-2170MHz 15.0dBi, E-Tilt: 0-20
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
14.7 68 14.5
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1850-1990 45° 14.7 65 13.9 0-20 ≥17(0°) ≥16(10°) ≥15(20°) ≥25(0-15o), ≥23(15-20o )(typ.) ≥17 ≤1.5:1 ≥28 <-150 300 50
1920-2170 15.0 63 13.0
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 680x145x86 / 26.8x5.7x3.4 4.5 / 9.9 6.5 / 14.3 Fiberglass, Light Grey SJA-B-14E(20) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
118 / 46 / 119 875x225x180 / 34.5x8.9x7.1 8.0 / 17.6 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-3 / 0116
Page 26 of 139
Outdoor Directional Single-band Antenna ODV-065R18K-G V1 X Pol, 65° 1710-2170MHz 17.8dBi, E-Tilt: 0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1850-1990 45° 17.5 68 6.8 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥25 ≥17 2 ≤1.5:1 ≥30 <-150 300 50
17.1 69 7.2
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @ 0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 17.8 65 6.3
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1335x120x60 / 52.6x4.7x2.4 5.8 / 12.8 7.5 / 16.5 Fiberglass, Light Grey SJA-B-14F(12) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
223 / 67 / 229 1565x190x130 / 61.6x7.5x5.1 8.5 / 18.7 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0116
Page 27 of 139
Outdoor Directional Single-band Antenna ODV-065R21K-G X Pol, 65° 1710-2170MHz 19.5dBi, E-Tilt: 0-8
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1850-1990 45° 19.2 65 4.5 0-8 ≥17(0°) ≥16(4°) ≥15(8°) ≥25 ≥18 3 3 ≤1.5:1 ≥30 <-150 300 50
19.0 67 4.6
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @ 0°(dB) Beam Tracking Avg. (dB) Squint (°) VSWR Isolation between Ports (dB) IM3 (2x43dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 19.5 63 4.2
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1960x145x86 / 77.2x5.7x3.4 10.6 / 23.4 13.4 / 29.5 Fiberglass, Light Grey 00-ZJ15(12) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
394 / 164 / 401 2350x225x185 / 92.5x8.9x7.3 17.2 / 37.9 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-4 / 0116
Page 28 of 139
Outdoor Directional Single-band Antenna ODV-090R17K-G X Pol, 90° 1710-2170MHz 16.3dBi, E-Tilt: 0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1850-1990 45° 16.3 88 6.8 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥25(typ.) ≥17 2 ≤1.5:1 ≥30 <-150 300 50
16.2 86 7.2
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 16.3 90 6.3
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1310x145x86 / 51.6x5.7x3.4 6.5 / 14.3 8.2 / 18.1 Fiberglass, Light Grey SJA-B-14D(10) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
250 / 103 / 258 1490x225x170 / 58.7x8.9x6.7 10.8 / 23.8 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0116
Page 29 of 139
Outdoor Directional Single-band Antenna ODV-065R18J-G X Pol, 65° 1710-2690MHz 17.8dBi, E-Tilt: 0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2690 1710-1880
1850-1990
17.0 65 7.4
17.3 63 7.0
1920-2170 45° 17.6 62 6.6 0-12
≥18(0°) ≥16(6°) ≥15(12°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
2300-2500
2490-2690
17.6 64 5.6
17.8 62 5.2 ≥17(0°) ≥16(6°) ≥15(12°)
≥25(typ.) ≥18(typ.) 2 ≤1.5:1 ≥28 <-150 250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (oC) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1365x160x83 / 53.7x6.3x3.3 9.2 / 20.3 11.2 / 24.7 Fiberglass, Light Grey SJA-B-14E(10) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
305 / 111 / 310 1560x230x170 / 61.4x9.1x6.7 14.0 / 30.9 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-4 / 0116
Page 30 of 139
XX-Pol Antenna Model
Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Length (mm)
ODP-065R12M14J-G
XX-Pol
698-960 / 1710-2690
12.0 / 15.6
65
FET 0 / FET 0
650
ODV-065R14M17J-G
XX-Pol
698-960 / 1710-2690
13.9 / 16.8
65
VET 0-14 / VET 0-10
1280
ODV-065R15M18J-G
XX-Pol
698-960 / 1710-2690
14.6 / 17.5
65
VET 0-14 / VET 0-10
1610
ODV-065R16M18J-G
XX-Pol
698-960 / 1710-2690
15.4 / 17.5
65
VET 0-10 / VET 0-10
1975
ODP-065R09BJ-G
XX-Pol
806-960 / 1710-2690
7.8 / 8.4
65
FET 0 / FET 0
340
ODP-065R09BJ-G(2J)
XX-Pol
806-960 / 1710-2690
7.8 / 8.4
65
FET 0 / FET 0
340
ODV-065R15E18K-G V2
XX-Pol
790-960 / 1710-2170
14.8 / 17.2
65
VET 0-14 / VET 0-10
1480
ODV-065R17E18K-G V1
XX-Pol
790-960 / 1710-2170
16.5 / 17.3
65
VET 0-10 / VET 0-10
1940
ODV-065R18EK-G
XX-Pol
790-960 / 1710-2170
17.0 / 17.5
65
VET 0-10 / VET 0-10
2515
ODV-065R17E18J-G
XX-Pol
790-960 / 1710-2690
16.1 / 18.0
65
VET 0-10 / VET 0-10
2000
ODV-065R18EJ-G
XX-Pol
790-960 / 1710-2690
17.0 / 18.0
65
VET 0-10 / VET 0-10
2765
ODV2-065R17E-G
XX-Pol
790-960 / 790-960
16.5 / 16.5
65
VET 0-10 / VET 0-10
1970
ODV2-065R18K-G V2
XX-Pol
1710-2170 / 1710-2170
17.8 / 17.8
65
VET 0-10 / VET 0-10
1310
ODV2-065R21K-G V1
XX-Pol
1710-2170 / 1710-2170
19.0 / 19.0
65
VET 0-8 / VET 0-8
1960
ODV2-065R16J-G
XX-Pol
1710-2690 / 1710-2690
15.6 / 15.6
65
VET 0-12 / VET 0-12
810
ODV2-065R18J-G V1
XX-Pol
1710-2690 / 1710-2690
17.9 / 17.9
65
VET 0-10 / VET 0-10
1400
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-1 / 1214
Page 31 of 139
Outdoor Directional Dual-band Antenna ODP-065R12M14J-G XX Pol, 65° 698-960/1710-2690MHz 12.0/15.6dBi, FET: 0/0
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Fixed Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
698-824
790-894
880-960
11.4 74 28.8
11.8 74 26.4 0 /
12.0 73 24.1
1710-1990 45° 14.9 65 13.6
1920-2170
2490- 2690
15.2 61 12.3 0 ≥14
15.6 65 9.8
≥25(typ.) ≥17 ≤1.5:1 ≥25 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (oC) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 650x320x145 / 25.6x12.6x5.7 8.8 / 19.4 10.8 / 23.8 Fiberglass, Light Grey SJA-B-14E(20) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
192 / 53 / 240 850x430x260 / 33.5x16.9x10.2 13.0 / 28.7 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
698-960 -45°
698-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 32 of 139
Outdoor Directional Dual-band Antenna ODV-065R14M17J-G XX Pol, 65° 698-960/1710-2690MHz 13.9/16.8dBi, E-Tilt: 0-14/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690
698-824
790-894
880-960
13.1 72 17.7
13.5 72 16.0 0-14 ≥17(0°) ≥16(7°) ≥14(14°)
13.9 68 14.3
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 16.0 65 10.4
1920-2170
2490-2690
16.5 62 9.4 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
16.8 61 7.4
≥25 ≥17 2 ≤1.5:1 ≥26
≥26 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1280x320x145 / 50.4x12.6x5.7 13.5 / 29.8 19.1 / 42.1 Fiberglass, Light Grey 00-ZJ10(16) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
434 / 109 / 550 1585x430x270 / 62.4x16.9x10.6 23.0 / 50.7 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
698-960 -45°
698-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Page 33 of 139
Outdoor Directional Dual-band Antenna ODV-065R15M18J-G XX Pol, 65° 698-960/1710-2690MHz 14.6/17.5dBi, E-Tilt: 0-14/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690
698-824
790-894
880-960
14.2 68 15.0
14.5 68 13.6 0-14 ≥16(0°) ≥15(7°) ≥14(14°)
14.6 67 12.2
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 16.5 64 7.3
1920-2170
2490-2690
17.1 63 6.6 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.5 65 5.0
≥25(typ.) ≥17(typ.) ≤1.5:1 ≥25
≥28 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1610x320x145 / 63.4x12.6x5.7 17.5/ 38.6 23.1/ 50.7 Fiberglass, Light Grey 00-ZJ10(12) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
574 / 140 / 729 1915x430x270 / 75.4x16.9x10.6 29.0 / 63.9 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
698-960 -45°
698-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:1-0-4 / 1215
Page 34 of 139
Outdoor Directional Dual-band Antenna ODV-065R16M18J-G XX Pol, 65° 698-960/1710-2690MHz 15.4/17.5dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690
698-824
790-894
880-960
14.9 67 11.0
15.3 65 10.1 0-10 ≥17(0°) ≥15(5°) ≥14(10°)
15.4 62 9.5
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 16.7 63 6.5
1920-2170
2490-2690
17.2 61 5.9 0-10 ≥16(0°) ≥16(5°) ≥14(10°)
17.5 63 4.8
≥25(typ.) ≥17 2 ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (Kg) / (lb) Lightning Protection
Specifications 1975x320x145 / 77.8x12.6x5.7 21.5 / 47.4 27.1 / 59.5 Fiberglass, Light Grey 00-ZJ10(12) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
740 / 172 / 945 2280x430x270 / 89.8x16.9x10.6 35.0 / 77.2 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
698-960 -45°
698-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:1-0-3 / 1215
Page 35 of 139
Outdoor Directional Dual-band Antenna ODP-065R09BJ-G XX Pol, 65° 806-960/1710-2690MHz 7.8/8.4dBi, FET: 0/0
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
806-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Fixed Electrical Downtilt (°) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
806-894
880-960
7.6 69 70
7.8 65 64
1710-1990 45° 8.2 60 56
0
1920-2170
2490- 2690
8.3 59 61 0
8.4 68 65
≥20 ≥15 ≤1.5:1 ≥25 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (oC) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 340x265x120 / 13.4x10.4x4.7 4.0 / 8.8 4.6 / 10.1 Fiberglass, Light Grey 00-ZJ16(20) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
80 / 24 / 94 455x340x230 / 17.9x13.4x9.1 5.6 / 12.3 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
806-960 -45°
806-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-1 / 1215
Page 36 of 139
Outdoor Directional Dual-band Antenna ODP-065R09BJ-G(2J) XX Pol, 65° 806-960/1710-2690MHz 7.8/8.4dBi, FET: 0/0
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
806-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Fixed Electrical Downtilt (°) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
806-894
880-960
7.6 69 70
7.8 65 64
1710-1990 45° 8.2 60 56
0
1920-2170
2490- 2690
8.3 59 61 0
8.4 68 65
≥20 ≥15 ≤1.5:1 ≥25 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (oC) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 340x265x120 / 13.4x10.4x4.7 4.5 / 9.9 5.1 / 11.2 Fiberglass, Light Grey 00-ZJ16(20) 2 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
80 / 24 / 94 455x340x230 / 17.9x13.4x9.1 6.1 / 13.4 Direct Ground
* TIA-222-G
Connector Position
806-960 1710-2690 -45°
DIN 7/16” F
806-960 1710-2690 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-0 / 1215
Page 37 of 139
Outdoor Directional Dual-band Antenna ODV-065R15E18K-G V2 XX Pol, 65° 790-960/1710-2170MHz 14.8/17.2dBi, E-Tilt: 0-14/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
14.3 68 14.4
14.8 66 13.5
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880 45° 16.9 65 7.1
0-14 ≥18(0°) ≥17(7°) ≥17(14°) ≥17(0°) ≥16(7°) ≥15(14°)
1st Upper Sidelobe Suppression (dB)
0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1850-1990
1920-2170
17.0 65 6.5 0-10 ≥17(0°) ≥16(5°) ≥16(10°) ≥16(0°) ≥15(5°) ≥15(10°)
17.2 62 6.2
≥25 ≥18 2 ≤1.5:1 ≥28 ≥30 <-150 500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1480x265x120 / 58.3x10.4 x4.7 14.5/ 32.0 20.1 / 44.1 Fiberglass, Light Grey 00-ZJ10(13) 4 x 7/16 DIN-Female, Bottom -50 to +70 95 150 / 200
Product Picture
430 / 110 / 515 1785x375x250 / 70.3x14.8x9.9 23.5 / 51.8 Direct Ground
*TIA-222-G
Connector Position
DIN 7/16” F
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:1-0-1 / 1215
Page 38 of 139
Outdoor Directional Dual-band Antenna ODV-065R17E18K-G V1 XX Pol, 65° 790-960/1710-2170MHz 16.5/17.3dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
16.0 68 10.5
16.5 65 9.8
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880 45° 17.1 65 7.2
0-10 ≥18(0°) ≥17(5°) ≥17(10°) ≥15
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1850-1990
1920-2170
17.0 64 6.7 0-10 ≥17(0°) ≥16(5°) ≥16(10°) ≥15
17.3 62 6.4
≥25 ≥18 2 ≤1.5:1 ≥29 ≥30 <-150 500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1940x265x120 / 76.4x10.4x4.7 19.5 / 43.0 25.8 / 56.9 Fiberglass, Light Grey 00-ZJ10(14) 4 x 7/16 DIN-Female, Bottom -50 to +70 95 150 / 200
Product Picture
584 / 147 / 701 2285x375x250 / 90.0x14.8x9.8 33.5 / 73.9 Direct Ground
* TIA-222-G
Connector Position
DIN 7/16” F
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +-45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-1 / 1215
Page 39 of 139
Outdoor Directional Dual-band Antenna ODV-065R18EK-G XX Pol, 65° 790-960/1710-2170MHz 17.0/17.5dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
16.5 68 8.0
17.0 65 7.5
Polarization Gain (dBi) Horizontal Beamwidth(°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880 45° 17.2 67 6.6
0-10 ≥17(0°) ≥16(5°) ≥15(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1850-1990
1920-2170
17.5 64 6.2 0-10 ≥18(0°) ≥17(5°) ≥16(10°)
17.5 63 5.8
≥25 ≥17 2 ≤1.5:1 ≥28 ≥30 <-150 500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2515x265x145/ 99.0x10.4x5.7 29.0 / 63.9 34.6 / 79.5 Fiberglass, Light Grey 00-ZJ10(08) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 /200
Product Picture
799 / 277 / 793 2830x375x275 / 111.4x14.8x10.8 41.0 / 90.4 Direct Ground
*TIA-222-G
Connector Position
DIN 7/16” F
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-5 / 1215
Page 40 of 139
Outdoor Directional Dual-band Antenna ODV-065R17E18J-G XX Pol, 65° 790-960/1710-2690MHz 16.1/18.0dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
15.8 68 9.5
16.1 66 8.9
Polarization Gain (dBi) Horizontal Beamwidth(°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1990 45° 17.2 68 6.1
0-10 ≥18(0°) ≥17(5°) ≥16(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR IsolationIntra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 17.6 63 5.6 0-10 ≥17(0°) ≥16(5°) ≥15(10°)
2490-2690 18.0 59 4.5
≥25(typ.) ≥18(typ.) 2
1 ≤1.5:1 ≥28 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2000x320x145 / 78.7x12.6x5.7 25.2 / 55.6 31.5 / 69.4 Fiberglass, Light Grey 00-ZJ11(08) 4 x 7/16 DIN-Female, Bottom -50 to +70 95 150 / 200
Product Picture
751 / 173 / 960 2340x430x270 / 92.1x16.9x10.6 38.5 / 84.9 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-2 / 1215
Page 41 of 139
Outdoor Directional Dual-band Antenna ODV-065R18EJ-G XX Pol, 65° 790-960/1710-2690MHz 17.0/18.0dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
16.6 64 6.8
17.0 62 6.0
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1990 45° 16.8 68 6.1
0-10 ≥18(0°) ≥17(5°) ≥16(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 17.3 64 5.6 0-10 ≥17(0°) ≥16(5°) ≥15(10°)
2490-2690 18.0 60 4.5
≥25(typ.) ≥18(typ.) 3 ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2765x320x145 / 108.9x12.6x5.7 31.0 / 68.4 41.3 / 91.1 Fiberglass, Light Grey 00-ZJ11(08) (three mounting points) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1124 / 245 / 1401 3100x430x270 / 122.0x16.9x10.6 50.0 / 110.3 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-4 / 1215
Page 42 of 139
Outdoor Directional Dual-band Antenna ODV2-065R17E-G XX Pol, 65° 790-960/790-960MHz 16.5/16.5dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
790-960
790-896
880-960 45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
16.0 68 10.0
16.5 63 9.2 0-10 / 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥25 ≥18 2 ≤1.5:1 ≥30 <-150 500 50
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports(dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port(W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1970x500x140 / 77.6x19.7x5.5 35.0 / 77.2 45.3 / 99.9 Fiberglass, Light Grey 00-ZJ11(12) (three mounting points) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1397 / 162 / 1735 2330x635x305 / 91.7x25.0x12.0 53.0 / 116.8 Direct Ground
*TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-2 / 1215
Page 43 of 139
Outdoor Directional Dual-band Antenna ODV2-065R18K-G V2 XX Pol, 65° 1710-2170/1710-2170MHz 17.8/17.8dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
1850-1990 45° 17.5 65 7.0 0-10 / 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥15 ≥25 ≥17 2 ≤1.5:1 ≥30 <-150 300 50
16.9 66 7.6
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 17.8 64 6.6
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1310x249x60 / 51.6x9.8x2.4 10.0 / 22.0 12.8 / 28.2 Fiberglass, Light Grey 00-ZJ15A(16) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
440 / 50 / 490 1613x367x312 / 63.5x14.4x12.3(3 in 1 Package) 43.0 / 94.8(3 in 1 Package) Direct Ground
* TIA-222-G
Connector Position
1710-2170 +45°
1710-2170 -45° 1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 1215
Page 44 of 139
Outdoor Directional Dual-band Antenna ODV2-065R21K-G V1 XXPol, 65° 1710-2170/1710-2170MHz 19.0/19.0dBi, E-Tilt: 0-8/0-8
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
1850-1990 45° 18.8 65 4.6 0-8 / 0-8 ≥17(0°) ≥16(4°) ≥15(8°) ≥25 ≥18 2 ≤1.5:1 ≥30 <-150 300 50
18.7 67 4.9
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170 19.0 65 4.4
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1960x249x60 / 77.2x9.8x2.4 14.0 / 30.9 19.6 / 43.2 Fiberglass, Light Grey 00-ZJ10(12) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
733 / 77 / 802 2295x360x175 / 90.4x14.2x6.9 22.0 / 48.5 Direct Ground
* TIA-222-G
Connector Position
1710-2170 +45°
1710-2170 -45° 1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0116
Page 45 of 139
Outdoor Directional Dual-band Antenna ODV2-065R16J-G XX Pol, 65° 1710-2690/1710-2690MHz 15.6/15.6dBi, E-Tilt: 0-12/0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2690
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880
1850-1990
14.8 69 13.6
15.0 67 12.7
1710-2690
1920-2170 45° 15.0 69 12.1 0-12 / 0-12
≥16(0°) ≥15(6°) ≥14(12°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
2300-2500
2490-2690
15.3 63 9.9
15.6 65 9.5 ≥15(0°) ≥14(6°) ≥13(12°)
≥25 ≥18(typ.) ≤1.5:1 ≥26 <-150 250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 810x300x86 / 31.9x11.8x3.4 11.0 / 24.3 16.2 / 35.7 Fiberglass, Light Grey SJA-B-12R(28) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
322 / 55 / 335 1095x415x215 / 43.1x16.3x8.5 20.0 / 44.1 Direct Ground
* TIA-222-G
Connector Position
1710-2690 +45°
1710-2690 -45° 1710-2690 +45°
1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 46 of 139
Outdoor Directional Dual-band Antenna ODV2-065R18J-G V1 XX Pol, 65° 1710-2690/1710-2690MHz 17.9/17.9dBi, E-Tilt: 0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2690 1710-1880
1850-1990
17.0 68 7.3
17.2 69 6.8
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1920-2170 45° 17.4 67 6.4 0-10 / 0-10 ≥17(0°) ≥16(5°) ≥14(10°) ≥14 ≥25 ≥18(typ.) 3 ≤1.5:1 ≥28 <-150 250 50
2300-2500
2490-2690
17.7 65 5.5
17.9 64 5.1
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1400x320x110 / 55.1x12.6x4.3 17.5 / 38.6 23.1 / 50.9 Fiberglass, Light Grey 00-ZJ10(16) 4 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
614 / 93 / 714 1700x435x215 / 66.9x17.1x8.5 27.0 / 59.5 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
DIN 7/16” F
1710-2690 +45°
1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-2 / 0116
Page 47 of 139
XXX-Pol Antenna Model
Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Length (mm)
ODP-065R12M14JJ-G
XXX-Pol
698-960 / 1710-2690 / 1710-2690
12.0 / 15.2 / 15.2
65
FET 0 / FET 0 / FET 0
650
ODV-065R14M17JJ-G
XXX-Pol
698-960 / 1710-2690 / 1710-2690
14.2 / 17.0 / 17.0
65
VET 0-14 / VET 0-10 / VET 0-10
1270
ODV-065R15M18JJ-G
XXX-Pol
698-960 / 1710-2690 / 1710-2690
14.7 / 18.0 / 18.0
65
VET 0-14 / VET 0-10 / VET 0-10
1500
ODV-065R16M18JJ-G
XXX-Pol
698-960 / 1710-2690 / 1710-2690
15.6 / 17.6 / 17.6
65
VET 0-10 / VET 0-10 / VET 0-10
2000
ODV-065R17M18JJ-G
XXX-Pol
698-960 / 1710-2690 / 1710-2690
16.8 / 17.5 / 18.0
65
VET 0-10 / VET 0-10 / VET 0-10
2680
ODV-065R15EKK
XXX-Pol
790-960 / 1710-2170 / 1710-2170
15.0 / 14.9 / 15.0
65
VET 0-14 / VET 0-14 / VET 0-14
1510
ODV-065R15E18KK-G V2
XXX-Pol
790-960 / 1710-2170 / 1710-2170
15.0 / 17.2 / 17.2
65
VET 0-14 / VET 0-10 / VET 0-10
1510
ODV-065R17E18KK-G V1
XXX-Pol
790-960 / 1710-2170 / 1710-2170
16.5 / 17.2 / 17.2
65
VET 0-10 / VET 0-10 / VET 0-10
1970
ODV-065R18EKK-G
XXX-Pol
790-960 / 1710-2170 / 1710-2170
16.9 / 17.1 / 17.2
65
VET 0-10 / VET 0-10 / VET 0-10
2715
ODV-065R15EJJ
XXX-Pol
790-960 / 1710-2690 / 1710-2690
14.8 / 15.0 / 15.0
65
VET 0-14 / VET 0-12 / VET 0-12
1415
ODV-065R17EJJ-G
XXX-Pol
790-960 / 1710-2690 / 1710-2690
16.0 / 17.1 / 17.4
65
VET 0-10 / VET 0-12 / VET 0-12
2000
ODV-065R18EJJ-G
XXX-Pol
790-960 / 1710-2690 / 1710-2690
17.0 / 17.2 / 17.8
65
VET 0-10 / VET 0-12 / VET 0-12
2765
ODV3-065R18K-G V1
XXX-Pol
1710-2170 / 1710-2170 / 17102170
17.7 / 17.7 / 17.7
65
VET 0-10 / VET 0-10 / VET 0-10
1350
ODI3-065R15J-G
XXX-Pol
1710-2690 / 1710-2690 / 17102690
15.5 / 15.5 / 15.5
65
VET 0-12 / VET 0-12 / VET 0-12
800
ODV3-065R18J-G V1
XXX-Pol
1710-2690 / 1710-2690 / 17102690
18.0 / 18.0 / 18.0
65
VET 0-10 / VET 0-10 / VET 0-10
1460
Page 48 of 139
Outdoor Directional Tri-band Antenna ODP-065R12M14JJ-G XXX Pol, 65° 698-960/1710-2690/1710-2690MHz 12.0/15.2/15.2dBi, FET: 0/0/0
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Fixed Electrical Downtilt (°) 1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power Per Port (W) Impedance (Ω)
1710-2690
698-824
790-894
880-960
11.8 68 28.5
12.0 69 26.5 0 /
12.0 71 23.5
1710-1990 45° 14.5 64 13.3
1710-2690
1920-2170
2490-2690
15.0 62 12.2 0/0 ≥15
15.2 62 9.5
≥25(typ.) ≥17 ≤1.5:1 ≥25 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 650x380x138 / 25.6x15.0x5.4 10.4 / 22.9 13.2 / 29.1 Fiberglass, Light Grey 00-ZJ15A(32) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤ 95 150 / 200
Product Picture
258 / 51 / 306 905x490x270 / 35.6x19.3x10.6 17.0 / 37.5 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
698-960 -45°
DIN 7/16” F
698-960 +45°
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
1710-2690 -45°
DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
Page 49 of 139
Outdoor Directional Tri-band Antenna ODV-065R14M17JJ-G XXX Pol, 65° 698-960/1710-2690/1710-2690MHz 14.2/17.0/17.0dBi, E-Tilt: 0-14/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2690
698-824
790-894
880-960
13.6 68 17.4
14.0 66 16.2 0-14 ≥17(0°) ≥15(7°) ≥14(14°)
14.2 66 14.8
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 15.9 65 9.5
1710-2690
1920-2170
2490-2690
16.6 61 8.6 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.0 63 6.6
≥25(typ.) ≥17 ≤1.5:1 ≥26
≥27 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (lb) Lightning Protection
Specifications 1270x380x138 / 50.0x15.0x5.4 18.5 / 40.8 24.1 / 53.1 Fiberglass, Light Grey 00-ZJ10(16) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
563 / 105 / 673 1585x490x270 / 62.4x19.3x10.6 30.0 / 66.1 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
698-960 -45°
698-960 +45°
1710-2690 +45°
DIN 7/16” F DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-0 / 0116
Page 50 of 139
Outdoor Directional Tri-band Antenna ODV-065R15M18JJ-G XXX Pol, 65° 698-960/1710-2690/1710-2690MHz 14.7/18.0/18.0dBi, E-Tilt: 0-14/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-824
790-894
1710-2690 880-960
1710-2690
1710-1990
1920-2170
2490-2690
17.0 65 6.4
17.4 63 5.9 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
18.0 64 4.6
45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
14.0 69 15.0
14.5 71 13.7 0-14 ≥16(0°) ≥15(7°) ≥14(14°)
1st Upper Sidelobe Suppression (dB)
14.7 67 12.4
≥14 ≥25(typ.) ≥17 ≤1.5:1
0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
≥25
≥28 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1500x380x138 / 59.1x15.0x5.4 24.5 / 54.0 30.8 / 67.9 Fiberglass, Light Grey 00-ZJ11(12) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
694 / 126 / 824 1815x490x270 / 71.5x19.3x10.6 37.5 / 82.7 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
698-960 -45°
698-960 +45°
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Page 51 of 139
Outdoor Directional Tri-band Antenna ODV-065R16M18JJ-G XXX Pol, 65° 698-960/1710-2690/1710-2690MHz 15.6/17.6/17.6dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-824
790-894
1710-2690 880-960
1710-2690
1710-1990
1920-2170
2490-2690
16.8 66 6.5
17.2 65 5.9 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.6 64 4.6
45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
15.3 69 10.6
15.4 70 9.6 0-10 ≥16(0°) ≥15(7°) ≥14(14°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
15.6 69 8.9
≥25(typ.) ≥17 ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2000x380x138 / 78.7x15.0x5.4 26.0 / 57.3 31.6 / 69.7 Fiberglass, Light Grey 00-ZJ10(08) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
999 / 171 / 1189 2340x490x270 / 92.1x19.3x10.6 38.6 / 85.1 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
698-960 -45°
698-960 +45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
DIN 7/16” F
DIN 7/16” F
Page 52 of 139
Outdoor Directional Tri-band Antenna ODV-065R17M18JJ-G XXX Pol, 65° 698-960/1710-2690/1710-2690MHz 16.8/17.5/18.0dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690
698-824
790-894
880-960
16.0
16.5
16.8
69 8.7
68 7.9 0-10 ≥17(0°) ≥16(5°) ≥14(10°)
68 7.4
Polarization Top Bottom
Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination@0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 16.3 16.8 63 7.2
1920-2170
1710-2690 2300-2500
16.9 16.9 17.5 17.6 61 64 6.5 5.5 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
2490-2690 17.5 18.0 65 5.0
≥25(typ.) ≥15 ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2680x320x145 / 105.5x12.6x5.7 34.0 / 75.0 43.8 / 97.7 Fiberglass, Light Grey 00-ZJ10(08) (three mounting points) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1081 / 238 / 1350 2995x430x270 / 117.9x16.9x10.6 52.5 / 115.7 Direct Ground
*TIA-222-G
Connector Position
1710-2690 +45°
1710-2690 +45°
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
698-960 +45° ° 698-960 -45°
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:0-0-2 / 0116
Page 53 of 139
Outdoor Directional Tri-band Antenna ODV-065R15EKK XXX Pol, 65° 790-960/1710-2170/1710-2170MHz 15.0/14.9/15.0dBi, E-Tilt: 0-14/0-14/0-14
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
14.5
15.0
68
65
14.5
13.2
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
1710-1880 45° 14.6 14.6 65 67 13.2 13.2
0-14 ≥17(0°) ≥16(7°) ≥16(14°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2170
1850-1990
1920- 2170
14.8 14.9 64 64 12.6 12.6 0-14 / 0-14 ≥16(0°) ≥15(7°) ≥15(14°)
14.9 15.0 63 63 11.7 12.0
≥25(typ.) ≥17 2 ≤1.5:1 ≥28 ≥30 <-150 500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1510x265x145 / 59.4x10.4x5.7 19.2 / 42.3 24.8 / 54.7 UV Resistant PVC, Light Grey 00-ZJ10(12) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150/200
Product Picture
432 / 160 / 432 1825x375x275 / 71.9x14.8x10.8 29.0 / 63.9 Direct Ground
*TIA-222-G
Connector Position 1710-2170 +45°
1710-2170 -45° 790-960 +45°
790-960 -45°
1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-1 / 0116
DIN 7/16” F
Page 54 of 139
Outdoor Directional Tri-band Antenna ODV-065R15E18KK-G V2 XXX Pol, 65° 790-960/1710-2170/1710-2170MHz 15.0/17.2/17.2dBi, E-Tilt: 0-14/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
790-896
880-960
14.5 64 14.6
15.0 61 13.4
1710-1880 45° 16.8 64 7.2
0-14 ≥18(0°) ≥17(7°) ≥16(14°)
1st Upper Sidelobe Suppression (dB)
1710-2170
1850-1990
1920-2170
17.0 63 6.7 0-10 / 0-10 ≥17(0°) ≥16(5°) ≥16(10°)
17.2 62 6.3
≥15 ≥25(typ.) ≥18 ≤1.5:1 ≥28 ≥30 <-150
0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1510x320x145 / 59.4x12.6x5.7 20.0 / 44.1 25.6 / 56.4 Fiberglass, Light Grey 00-ZJ10(13) 6 x 7/16 DIN-Female, Bottom -50 to +70 95 150 / 200
Product Picture
531 / 131 / 674 1845x430x270 / 72.6x16.9x10.6 31.7 / 69.9 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
DIN 7/16” F
1710-2170 +45°
DIN 7/16” F
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
1710-2170 -45° °
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-1 / 0116
1710-2170 +45°
DIN 7/16” F
Page 55 of 139
Outdoor Directional Dual-band Antenna ODV-065R17E18KK-G V1 XXX Pol, 65° 790-960/1710-2170/1710-2170MHz 16.5/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
790-896
880-960
16.0 62 10.5
16.5 59 9.7
1710-1880 45° 16.8 64 7.3
0-10 ≥18(0°) ≥17(5°) ≥17(10°)
1st Upper Sidelobe Suppression (dB)
1710-2170
1850-1990
1920-2170
17.0 61 6.7 0-10 ≥17(0°) ≥16(5°) ≥16(10°)
17.2 60 6.4
≥15 ≥25 ≥18 ≤1.5:1 ≥28 ≥30 <-150
0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1970x320x145 / 77.6x12.6x5.7 24.5 / 54 30.1 / 66.4 Fiberglass, Light Grey 00-ZJ10(12) 6 x 7/16 DIN-Female, Bottom -50 to +70 95 150 / 200
Product Picture
738 / 171 / 942 2280x430x270 / 89.8x16.9x10.6 37.5 / 82.7 Direct Ground
* TIA-222-G
Connector Position
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +45°
1710-2170 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 56 of 139
Outdoor Directional Tri-band Antenna ODV-065R18EKK-G XXX Pol, 65° 790-960/1710-2170/1710-2170MHz 16.9/17.1/17.2dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
16.5
16.9
68
65
8.0
7.0
Polarization Gain (dBi) Horizontal Beamwidth(°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
1710-1880 45° 16.7 16.9 66 65 6.7 7.3
0-10 ≥17(0°) ≥16(5°) ≥15(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2170
1850-1990
1920- 2170
17.0 17.1 63 64 6.3 6.9 0-10 / 0-10
17.1 17.2 62 63 6.0 6.6
Top: ≥18(0°); ≥16(5°); ≥15(10°) Bottom: ≥17(0°); ≥15(5°); ≥13(10°) ≥25 ≥18 2 ≤1.5:1 ≥28 ≥30 <-150
500
300 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2715x265x145 / 106.9x10.4x5.7 33.0 / 72.8 42.0 / 92.6 Fiberglass, Light Grey SJA-B-12R(08) (three mounting points) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
875 / 300 / 866 3055x375x275 / 120.3x14.8x10.8 48.0 / 105.8 Direct Ground
*TIA-222-G
Connector Position 1710-2170 +45°
1710-2170 -45° 790-960 +45°
790-960 -45°
1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-3 / 0116
DIN 7/16” F
Page 57 of 139
Outdoor Directional Tri-band Antenna ODV-065R15EJJ XXX Pol, 65° 790-960/1710-2690/1710-2690MHz 14.8/15.0/15.0dBi, E-Tilt: 0-14/0-12/0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
Polarization Gain (dBi) Horizontal Beamwidth(°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2690
790-896
880-960
1710-1880
14.5 68 14.5
14.8 66 13.2
13.7 69 16.3
1850-1990 45° 14.0 67 15.2
0-14 ≥17(0°) ≥16(7°) ≥15(14°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1920-2170
2300-2500
2490-2690
14.5 64 14.1 0-12/0-12 ≥16(0°) ≥15(6°) ≥14(12°)
15.0 57 12.1
15.0 55 11.0
≥25(typ.) ≥17 ≤1.5:1 ≥28
≥25 ≥28 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1415x335x145 / 55.7x13.2x5.7 19.5 / 43.0 25.1 /55.3 UV Resistant PVC, Light Grey 00-ZJ10(16) 6x7/16 DIN-Female, Bottom -40 to +60 ≤95 150 / 200
Product Picture
514 / 122 / 651 1740x450x270 / 68.5x17.7x10.6 30.5 / 67.2 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-3 / 0116
Page 58 of 139
Outdoor Directional Tri-band Antenna ODV-065R17EJJ-G XXX Pol, 65° 790-960/1710-2690/1710-2690MHz 16.0/17.1/17.4dBi, E-Tilt: 0-10/0-12/0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
15.4
16.0
68
66
9.6
9.0
2490-2690
15.6 16.0 67 68 9.3 9.5
17.1 17.4 57 57 6.5 6.5
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥18(0°) ≥17(5°) ≥16(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 ( 2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1710-1880
500
1850-1990 1920-2170 45° 15.9 16.0 16.3 16.5 65 64 66 64 8.7 8.3 8.7 8.2 0-12 / 0-12 ≥18(0°) ≥17(6°) ≥16(12°) ≥25(typ.) ≥18 2 ≤1.5:1 ≥28 ≥28 <-150 250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2000x320x145 / 78.7x12.6x5.7 28.7 / 63.3 35.0 / 77.2 Fiberglass, Light Grey 00-ZJ11(08) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤ 95 150/200
Product Picture
751 / 173 / 960 2340x430x270 / 92.1x16.9x10.6 42.0 / 92.6 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-2 / 0116
Page 59 of 139
Outdoor Directional Tri-band Antenna ODV-065R18EJJ-G XXX Pol, 65° 790-960/1710-2690/1710-2690MHz 17.0/17.2/17.8dBi, E-Tilt: 0-10/0-12/0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
16.7
17.0
68
65
6.7
6.0
1710-1990 45° 16.3 16.6 68 68 7.0 7.0
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥18(0°) ≥16(5°) ≥15(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1920-2170
2490- 2690
16.9 17.2 65 65 6.5 6.5 0-12/0-12 ≥17(0°) ≥16(6°) ≥15(12°)
17.2 17.8 58 57 5.2 5.2
≥25(typ.) ≥18(typ.) 3 ≤1.5:1 ≥28 ≥28 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2765x320x145 / 108.9x12.6x5.7 36.0 / 79.4 46.3 / 102.1 Fiberglass, Light Grey 00-ZJ11(08) (three mounting points) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1124 / 245 / 1401 3100x430x270 / 122.0x16.9x10.6 56.0 / 123.5 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
1710-2690 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-5 / 0116
Page 60 of 139
Outdoor Directional Tri-band Antenna ODV3-065R18K-G V1 XXX Pol, 65° 1710-2170/1710-2170/1710-2170MHz 17.7/17.7/17.7dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2170 1710-1880
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170 1850-1990 45° 17.4 64 7.0 0-10 / 0-10 / 0-10 ≥18(0°) ≥17(5°) ≥16(10°) ≥15 ≥25(typ.) ≥17 3 ≤1.5:1 ≥28 <-150 300 50
17.0 64 7.5
1st Upper Sidelobe Suppression (dB) 0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation between Ports(dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2170 1920-2170 17.7 64 6.5
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1350x380x65 / 53.1x15.0x2.6 16.2 / 35.7 21.8 / 48.1 Fiberglass, Light Grey 00-ZJ10(16) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
760 / 53 / 827 1700x490x180 / 66.9x19.3x7.1 26.2 / 57.8 Direct Ground
*TIA-222-G
Connector Position
1710-2170 +45°
1710-2170 -45° 1710-2170 +45°
1710-2170 -45°
DIN 7/16” F
1710-2170 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:2-0-0 / 0116
Page 61 of 139
Outdoor Directional Tri-band Antenna ODI3-065R15J-G XXX Pol, 65° 1710-2690/1710-2690/1710-2690MHz 15.5/15.5/15.5dBi, E-Tilt: 0-12/0-12/0-12 Integrated RCU
Electrical Specifications Frequency Range (MHz) 1710-2690
Parameters / Specifications Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880
1850-1990
14.8 67 12.4
14.8 71 11.5
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio @180°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation between Ports(dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690 1920-2170 45° 14.9 70 10.9 0-12 / 0-12 / 0-12 ≥17(0°) ≥16(6°) ≥15(12°) ≥25(typ.) ≥17 ≤1.5:1 ≥28 <-150 250 50
1710-2690 2300-2500
2490-2690
15.3 64 9.4
15.5 67 8.7
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 800x500x140/ 31.5x19.7x5.5 18.0 / 39.7 23.6 / 52.0 Fiberglass, Light Grey 00-ZJ10(30) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
467 / 61 / 547 1100x635x305 / 43.3x25.0x12.0 29.0 / 63.9 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 -45°
1710-2690 +45°
1710-2690 +45°
DIN 7/16” F DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
AISG IN AISG OUT
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:0-0-1 / 0116
Page 62 of 139
Outdoor Directional Tri-band Antenna ODV3-065R18J-G V1 XXX Pol, 65° 1710-2690/1710-2690/1710-2690MHz 18.0/18.0/18.0dBi, E-Tilt: 0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
1710-2690
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-1880
1850-1990
17.3 66 7.2
17.3 68 6.8
1710-2690 1920-2170 45° 17.4 67 6.5 0-10 / 0-10 / 0-10
≥16(0°) ≥16(5°) ≥16(10°)
1st Upper Sidelobe Suppression (dB)
1710-2690 2300-2500
2490-2690
17.8 64 5.5
18.0 68 5.1 ≥17(0°) ≥16(5°) ≥15(10°)
≥14 ≥25(typ.) ≥17 ≤1.5:1 ≥28 <-150 250 50
0-30°Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation between Ports(dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Front / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1460x500x140 / 57.5x19.7x5.5 30.5 / 67.2 36.8 / 81.1 Fiberglass, Light Grey 00-ZJ11(16) 6 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
962 / 117 / 1165 1815x635x305 / 71.5x25.0x12.0 43.5 / 95.9 Direct Ground
*TIA-222-G
Connector Position
1710-2690 -45°
1710-2690 +45°
1710-2690 -45°
1710-2690 +45°
1710-2690 -45° °
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
©Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-0 / 0116
Page 63 of 139
XXXX-Pol Antenna Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Length (mm)
ODV-065R17M18JJJ-G
XXXX-Pol
698-960 / 1710-2690 / 1710-2690 / 1710-2690
16.6 / 16.8 / 17.6 / 17.6
65
VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
2680
ODI-065R15NG18JJ-G
XXXX-Pol
698-862 / 880-960 / 1710-2690 / 1710-2690
14.3 / 14.4 / 17.9 / 17.9
65
VET 2-16 / VET 2-16 / VET 2-12 / VET 2-12
1500
XXXX-Pol
790-960 / 1710-2170 / 1710-2690 / 1710-2690
13.5 / 14.9 / 16.3 / 16.3
65
VET 0-14 / VET 0-10 / VET 0-10 / VET 0-10
800
ODI-065R15E18KJJ-G
XXXX-Pol
790-960 / 1710-2170 / 1710-2690 / 1710-2690
15.1 / 17.2 / 17.7 / 17.7
65
VET 0-14 / VET 0-10 / VET 0-10 / VET 0-10
1500
ODV-065R17EKJJ-G
XXXX-Pol
790-960 / 1710-2170 / 1710-2690 / 1710-2690
16.2 / 16.2 / 16.4 / 16.8
65
VET 0-10 / VET 0-10 / VET 0-12 / VET 0-12
2000
ODV-065R17E18JJJ-G
XXXX-Pol
790-960 / 1710-2690 / 1710-2690 / 1710-2690
17.1 / 17.1 / 17.2 / 17.2
65
VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
2680
ODV2-065R17E18J-G
XXXX-Pol
790-960 / 790-960 / 1710-2690 / 1710-2690
16.6 / 16.6 / 16.8 / 17.0
65
VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
2250
Model
ODI-065R12E15KJJ-G
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0514
Page 64 of 139
Outdoor Directional Quad-band Antenna ODV-065R17M18JJJ-G XXXX Pol, 65° 698-960/1710-2690/1710-2690/1710-2690MHz 16.6/16.8/17.6/17.6dBi, E-Tilt: 0-10/0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690
698-824
790-894
880-960
16.0
16.3
16.6
70 8.0
67 7.5 0-10 ≥17(0°) ≥16(5°) ≥14(10°)
68 7.0
Polarization Top Bottom
Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-1990 45° 16.0 16.5 65 7.0
1710-2690
1710-2690
1920-2170
2490-2690
16.4 17.1 62 6.5 0-10 / 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
16.8 17.6 64 5.0
≥25(typ.) ≥15 ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2680x380x138 / 105.5x15.0x5.4 36.5 / 80.5 46.8 / 103.2 Fiberglass, Light Grey 00-ZJ11(08) (three mounting points) 10 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200 1452 / 233 / 1744 2995x490x270 / 117.9x19.3x10.6 55.7 / 122.8 Direct Ground
* TIA-222-G
Connector Position
1710-2690 +45°
1710-2690 +45°
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
698-960 +45° ° 698-960 -45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-1 / 0116
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
Page 65 of 139
Outdoor Directional Quad-band Antenna ODI-065R15NG18JJ-G XXXX Pol, 65° 698-862/880-960/1710-2690/1710-2690MHz 14.3/14.4/17.9/17.9dBi, E-Tilt: 2-16/2-16/2-12/2-12 Integrated RCU
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-862 698-824
880-960 790-862
1710-2690
880-960
1710-2690
1710-1990
1920-2170
2490-2690
16.9 64 7.4
17.4 62 6.6 2-12 / 2-12 ≥17(2°) ≥16(7°) ≥14(12°)
17.9 64 4.9
45°
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
14.0 68 14.9
14.3 65 13.9
14.4 65 12.6 2-16
2-16 ≥16(2°) ≥14(9°) ≥14(16°)
st
1 Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
≥25(typ.) ≥18(typ.)
≥20(typ.) ≤1.5:1 ≥28 ≥30 <-150
500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1500x380x138 / 59.1x15.0x5.4 30.5 / 67.2 36.1 / 79.5 Fiberglass, Light Grey 00-ZJ10(12) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
694 / 126 / 824 1965x490x270 / 77.4x19.3x10.6 43.5 / 95.9 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
880-960 -45°
880-960 +45°
698-862 -45°
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F DIN 7/16” F
698-862 +45°
1710-2690 +45°
1710-2690 -45°
AISG IN AISG OUT DIN 7/16” F DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-4 / 0116
DIN 7/16” F DIN 7/16” F DIN 7/16” F
Page 66 of 139
Outdoor Directional Quad-band Antenna ODI-065R12E15KJJ-G XXXX Pol, 65° 790-960/1710-2170/1710-2690/1710-2690MHz 13.5/14.9/16.3/16.3dBi, E-Tilt: 0-14/0-10/0-10/0-10 Integrated RCU
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
12.9 61 24.5
13.5 60 23.0
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
0-14 ≥15(0°) ≥15(7°) ≥14(14°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
500
1710-1990
1710-2690
1920-2170 45° 14.7 14.9 62 59 12.3 11.1 0-10 ≥13(0°) ≥12(5°) ≥11(10°) ≥25(typ.) ≥17 ≤1.5:1 ≥25 ≥30 <-150 300 50
1710-2690
1710-1990
1920-2170
2490-2690
14.7 71 12.0
15.2 69 11.0 0-10 / 0-10 ≥15(0°) ≥14(5°) ≥13(10°)
16.3 58 8.7
250
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 800x380x138 / 31.5x15.0x5.4 15.5 / 34.2 18.3 / 40.3 Fiberglass, Light Grey 00-ZJ15A(25) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
326 / 63 / 388 1090x490x260 / 42.9x19.3x10.2 21.6 / 47.6 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +45°
1710-2690 +45°
DIN 7/16” F DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F AISG IN AISG OUT
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
Page 67 of 139
Outdoor Directional Quad-band Antenna ODI-065R15E18KJJ-G XXXX Pol, 65° 790-960/1710-2170/1710-2690/1710-2690MHz 15.1/17.2/17.7/17.7dBi, E-Tilt: 0-14/0-10/0-10/0-10 Integrated RCU
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) Electrical Downtilt (°)
1710-2170
790-896
880-960
14.6 61 14.8
15.1 58 13.6 0-14 ≥17(0°) ≥16(7°) ≥15(14°)
st
1 Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
3
500
1710-1990
1920-2170 45° 16.9 17.2 65 60 6.4 5.8 0-10 ≥17(0°) ≥16(5°) ≥14(10°) ≥25(typ.) ≥17 2 ≤1.5:1 ≥28 ≥30 <-150 300 50
1710-2690
1710-2690
1710-1990
1920-2170
2490-2690
17.2 70 6.2
17.6 67 5.7 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.7 59 4.6
3
250
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 1500x380x138 / 59.1x15.0x5.4 24.5 / 54.0 30.1 / 66.3 Fiberglass, Light Grey 00-ZJ10(16) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
694 / 126 / 824 1815x490x270 / 71.5x19.3x10.6 37.5 / 82.7 Direct Ground
* TIA-222-G
Connector Position
1710-2690 -45°
1710-2170 -45°
1710-2170 +45°
790-960 -45°
790-960 +45°
1710-2690 +45°
DIN 7/16” F DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F DIN 7/16” F
AISG IN AISG OUT
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Page 68 of 139
Outdoor Directional Quad-band Antenna ODV-065R17EKJJ-G XXXX Pol, 65° 790-960/1710-2170/1710-2690/1710-2690MHz 16.2/16.2/16.4/16.8dBi, E-Tilt: 0-10/0-10/0-12/0-12
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2170
790-896
880-960
1710-1990
1920-2170 45°
15.8
16.2
16.0
16.2
64
62
66
62
10.2
9.2
7.8
7.2
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥17(0°) ≥16(5°) ≥15(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) Beam Tracking Avg. (dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
0-10 ≥17(0°) ≥16(5°) ≥15(10°) ≥25(typ.) ≥18(typ.) 2 ≤1.5:1 ≥28 ≥30 <-150 300 50
500
1710-2690
1710-2690
1710-1990
1920-2170
2490-2690
15.8 16.2 66 68 9.2 9.1
16.1 16.5 64 65 8.3 8.2 0-12 / 0-12 ≥17(0°) ≥16(6°) ≥15(12°)
16.4 16.8 61 60 6.5 6.4
250
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (lb) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2000x380x138 / 78.7x15.0x5.4 32.0 / 70.5 37.6 / 82.9 Fiberglass, Light Grey 00-ZJ10(08) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
999 / 171 / 1189 2340x490x270 / 92.1x19.3x10.6 45.0 / 99.2 Direct Ground
* TIA-222-G
Connector Position
1710-2690 +45°
1710-2170 -45°
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
790-960 -45°
1710-2170 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-2 / 0116
790-960 +45°
DIN 7/16” F
DIN 7/16” F
Page 69 of 139
Outdoor Directional Quad-band Antenna ODV-065R17E18JJJ-G XXXX Pol, 65° 790-960/1710-2690/1710-2690/1710-2690MHz 17.1/17.1/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
16.6
17.1
61
58
7.9
7.2
1710-1990 45° 16.3 16.7 69 69 7.2 7.2
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥17(0°) ≥16(5°) ≥14(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1710-2690
1920-2170
2490-2690
16.6 16.9 66 65 6.5 6.5 0-10 / 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.1 17.2 61 60 5.1 5.3
≥25(typ.) ≥17(typ.) ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2680x380x138 / 105.5x15.0x5.4 39.0 / 85.9 49.3 / 108.6 Fiberglass, Light Grey 00-ZJ11(08) (three mounting points) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1453 / 234 / 1745 2995x490x270 / 117.9x19.3x10.6 59.5 / 131.2 Direct Ground
* TIA-222-G
Connector Position
1710-2690 +45°
1710-2690 +45°
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
790-960 +45° ° 790-960 -45°
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-3 / 0116
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
Page 70 of 139
Outdoor Directional Quad-band Antenna ODV2-065R17E18J-G XXXX Pol, 65° 790-960/790-960/1710-2690/1710-2690MHz 16.6/16.6/16.8/17.0dBi, E-Tilt: 0-10/0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) 790-960 Parameters / Specifications
1710-2690
1710-2690
790-960 790-896
880-960
16.1
16.6
68
66
9.0
8.3
1710-1990
2490-2690
15.9 16.2 60 60 7.9 7.5
16.8 17.0 64 65 6.0 5.3
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 / 0-10 ≥15(0°) ≥13(5°) ≥13(10°) ≥11 ≥11
st
1 Upper Sidelobe Suppression (dB) 0-30° Upper Sidelobe Suppression (dB) 0-180° Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IMD3 ( 2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
500
1920-2170 2300-2500 45° 16.1 16.4 16.3 16.6 59 65 60 66 7.6 7.1 7.1 5.8 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥15(10°) ≥12 ≥7 ≥25 ≥18 ≤1.5:1 ≥27 ≥28 <-150 250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2250x500x140 / 88.6x19.7x5.5 39.8 / 87.7 49.6 / 109.3 Fiberglass, Light Grey 00-ZJ10(12) (three mounting points) 8 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1658/ 185 / 2085 2630x635x305 / 103.5x25.0x12.0 59.8 / 131.8 Direct Ground
* TIA-222-G
Connector Position
790-960 -45°
790-960 +45°
1710-2690 -45°
1710-2690 +45°
1710-2690 -45°
1710-2690 +45°
790-960 -45°
790-960 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 1215
Page 71 of 139
XXXXX-Pol Antenna Model
Pol
Frequency (MHz)
Gain (dBi)
HPBW (deg)
ODV-065R17M18JJJJ-G
XXXXX-Pol
698-960 / 1710-2690 / 1710-2690 / 1710-2690 / 1710-2690
16.7 / 17.2 / 17.2 / 17.9 / 17.9
65
XXXXX-Pol
698-806 / 824-960 / 1710-2690 / 1710-2690 / 1710-2690
15.0 / 15.7 / 16.0 / 16.7 / 16.7
XXXXX-Pol
790-960 / 1710-2690 / 1710-2690 / 1710-2690 / 1710-2690
17.1 / 17.2 / 17.2 / 17.2 / 17.2
ODI-065R16NB17JJJ-G
ODV-065R17E18JJJJ-G
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0514
Tilt (deg) VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
Length (mm)
2680
65
VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
2400
65
VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10 / VET 0-10
2680
Page 72 of 139
Outdoor Directional Penta-band Antenna ODV-065R17M18JJJJ-G XXXXX Pol, 65° 698-960/1710-2690/1710-2690/1710-2690/1710-2690MHz 16.7/17.2/17.2/17.9/17.9dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960
1710-2690 1710-2690 1710-2690 1710-2690
698-824
790-896
880-960
16.0
16.6
16.7
68
66
68
8.7
7.7
7.1
1710-1990 45° 16.2 16.8 65 63 7.4 7.3
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥17(0°) ≥16(5°) ≥14(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1920-2170
2300-2500
16.6 16.6 17.3 17.2 64 62 64 62 6.7 5.5 6.6 5.5 0-10 / 0-10 / 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
2490-2690 17.2 17.9 64 63 5.1 5.1
≥25(typ.) ≥17(typ.) ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2680x380x138 / 105.5x15.0x5.4 43.0 / 94.8 52.8 / 116.4 Fiberglass, Light Grey 00-ZJ10(08) (three mounting points) 10 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1453 / 234 / 1745 2995x490x270 / 117.9x19.3x10.6 63.5 / 140.0 Direct Ground
* TIA-222-G
Connector Position 698-960 +45°
698-960 -45° 1710-2690 +45°
1710-2690 +45° 1710-2690 -45°
DIN 7/16” FDIN
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F DIN 7/16” F
DIN 7/16” F DIN 7/16” F DIN 7/16” F
1710-2690 -45° 1710-2690 +45°
DIN 7/16” F
DIN 7/16” F DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-2 / 0216
Page 73 of 139
Outdoor Directional Penta-band Antenna ODI-065R16NB17JJJ-G XXXXX Pol, 65° 698-806/824-960/1710-2690/1710-2690/1710-2690MHz 15.0/15.7/16.0/16.7/16.7dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10 Integrated RCU
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
824-960
698-806
1710-2690
698-806
824-894
880-960
15.0
15.5
15.7
67
65
66
10.3
9.1
8.6
1710-1990 45° 15.4 15.9 66 8.7 7.9
Polarization Top Bottom Horizontal Beamwidth (°) Top Vertical Beamwidth (°) Bottom Electrical Downtilt (°) Gain (dBi)
0-10
0-10 ≥14(0°) ≥13(5°) ≥13(10°)
st
1 Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1710-2690
1920-2170
2490-2690
15.9 16.7 65 7.8 7.1 0-10 / 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
16.0 16.7 65 6.1 5.5
≥25(typ.) ≥18(typ.) ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2400x380x138 / 94.5x15.0x5.4 42.0 / 92.6 51.8 / 114.2 Fiberglass, Light Grey 00-ZJ10(12)(three mounting points) 10 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1259 / 208 / 1507 2715x490x270 / 106.9x19.3x10.6 62.0 / 136.7 Direct Ground
* TIA-222-G
Connector Position
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
824-960 +45°
698-806 -45°
824-960 -45°
DIN 7/16” F DIN 7/16” F
1710-2690 -45°
698-806 +45°
DIN 7/16” F
DIN 7/16” F
DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
DIN 7/16” F
1710-2690 +45° 1710-2690 -45°
DIN 7/16” F
DIN 7/16” F
AISG IN AISG OUT
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-3 / 0116
Page 74 of 139
Outdoor Directional Penta-band Antenna ODV-065R17E18JJJJ-G XXXXX Pol, 65° 790-960/1710-2690/1710-2690/1710-2690/1710-2690MHz 17.1/17.2/17.2/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
790-960
1710-2690
790-896
880-960
16.6
17.1
61
58
7.9
7.2
1710-1990 45° 16.3 16.7 69 69 7.2 7.2
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°)
Top Bottom Top Bottom Top Bottom
Electrical Downtilt (°)
0-10 ≥17(0°) ≥16(5°) ≥14(10°)
1st Upper Sidelobe Suppression (dB) Front-To-Back Ratio 180°30°(dB) Cross-polar Discrimination @0°(dB) VSWR Isolation Intra-system (dB) Isolation Inter-system (dB) IM3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
1710-2690
1710-2690
1710-2690
1920-2170
2490-2690
16.6 16.9 66 65 6.5 6.5 0-10 / 0-10 / 0-10 / 0-10 ≥16(0°) ≥15(5°) ≥14(10°)
17.2 17.2 61 60 5.1 5.3
≥25(typ.) ≥17(typ.) ≤1.5:1 ≥28 ≥30 <-150 500
250 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Weight, with Mounting Kit (kg) / (Ib) Radome Material and Color Mounting Kit Connector Type and Location Operational Temperature (°C) Operational Humidity (%) Operational/Max Wind Speed (km/h) Wind Load* @ 150km/h Frontal / Lateral / Rearside (N) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications 2680x380x138 / 105.5x15.0x5.4 43.0 / 94.8 54.3 / 117.5 Fiberglass, Light Grey 00-ZJ11(08) (three mounting points) 10 x 7/16 DIN-Female, Bottom -50 to +70 ≤95 150 / 200
Product Picture
1453 / 234 / 1745 2995x490x270 / 117.9x19.3x10.6 66.0 / 145.5 Direct Ground
* TIA-222-G
Connector Position 790-960 +45°
790-960 -45° 1710-2690 +45°
1710-2690 +45° 1710-2690 -45°
DIN 7/16” FDIN
1710-2690 -45°
1710-2690 -45°
DIN 7/16” F DIN 7/16” F
DIN 7/16” F DIN 7/16” F DIN 7/16” F
1710-2690 -45° 1710-2690 +45°
DIN 7/16” F
DIN 7/16” F DIN 7/16” F
1710-2690 +45°
DIN 7/16” F
7/16” F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-3 / 0116
Page 75 of 139
Indoor Antenna
Page 76 of 139
Indoor Antenna Indoor Antenna ............................................................................................................................................................................................... 78 IWH-090V08N0-D ................................................................................................................................................................................ 79 IXD-360V03NN(05) .............................................................................................................................................................................. 80 IXD-360V03NU(05) .............................................................................................................................................................................. 81 IXD-360VH03NN .................................................................................................................................................................................. 82 IWH-090VR08NT ................................................................................................................................................................................. 83
Page 77 of 139
Indoor Antenna Model
POL
Frequency (MHz)
Gain (dBi)
HPBW (deg)
Tilt (deg)
Dimension (mm)
IWH-090V08N0-D
V-Pol
698-960/1710-2700
5.5/7.5
90
-
210x180x44
IXD-360V03NN(05)
V-Pol
670-960/1710-2700
2.0/4.0
360
-
Φ208x112
IXD-360V03NU(05)
V-Pol
600-960/1710-4000
2.0/4.0
360
-
Φ208x112
IXD-360VH03NN
VH Pol
698-960 / 1710-2700
4.0 / 4.8
360°
-
Φ 210 x 41
IWH-090VR08NT
VX-Pol
790-960/1710-2700MHz
7.0 / 8.2
90
-
278x176x62
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0814
Page 78 of 139
Indoor Directional Wall Mounted Antenna IWH-090V08N0-D V Pol, 90° 698-960/1710-2700MHz 5.5/7.5dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-960 698-800
Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) VSWR IMD3 (2x33 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
3.5 120 81 ≤1.8:1
1710-2700 800-960 Vertical 5.5 93 77
1710-2700 7.5 56 35 ≤1.5:1
≤-140 50 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Radome Material and Color Connector Type and Location Operational Temperature (°C) Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 210x180x44 / 8.3x7.1x1.7 0.6 / 1.3 ABS, White 1 x N-Female, Bottom -30 to +45 Wall Mounted 255x190x60 / 10.0x7.5x2.4 0.8 / 1.8 Indoor
Product Picture
Connector Position & Installation Guide
698-960 1710-2700
N-FDIN 7/16” F
Installation Steps 1) 2) 3) 4)
Drill four holes in wall per pattern of holes in plate (item 2) shown above Attach flat side of plate (item 2) to wall using wall anchors (item 4) and screws (item 3) Mount antenna (item 1), to plate (item 2) Connect RF cable
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0415
Page 79 of 139
Indoor Omni-directional Ceiling Mounted Antenna IXD-360V03NN(05) V Pol, 360° 670-960/1710-2700MHz 2.0/4.0dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
670-960 670-696
Polarization Gain (dBi) Horizontal Beamwidth (°) VSWR IMD3 (2x33 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
696-806
1710-2700 806-960 Vertical
1710-2500
2.0
2500-2700 4.0
360 ≤2.5:1
≤2.0:1
≤1.5:1 <-140 100 50
Mechanical Specifications Parameters Dimensions, Diameter x Length (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Radome Material and Color Connector Type and Location Operational Temperature (°C) Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications Φ208x112 / Φ8.2x4.4 0.4 / 0.9 ABS, White 1 x N-Female, Bottom -30 to +45 Ceiling Mounted 175x175x180 / 6.9x6.9x7.1 0.5 / 1.1 Indoor
Product Picture
Connector Position & Installation Drawing
670-960 1710-2700
N- F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-4 / 1214
Page 80 of 139
Indoor Omni-directional Ceiling Mounted Antenna IXD-360V03NU(05) V Pol, 360° 600-960/1710-4000MHz 2.0/4.0dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
600-960 600-698
Polarization Gain (dBi) Horizontal Beamwidth (°) VSWR IMD3 (2x43 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
698-790
1710-4000 790-960
1710-2700
2700-4000
Vertical 2.0
4.0 360
≤3.5:1
≤2.0:1
≤1.5:1
≤1.5:1
≤2.0:1
<-153 100 50
Mechanical Specifications Parameters Dimensions, Diameter x Length (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Radome Material and Color Connector Type and Location Operational Temperature (°C) Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications Φ208x112 / Φ8.2x4.4 0.45 / 1.0 ABS, White 1 x N-Female, Bottom -30 to +45 Ceiling Mounted 175x175x180 / 6.9x6.9x7.1 0.55 / 1.2 Indoor
Product Picture
Connector Position
600-960 1710-4000
N- F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:1-0-2 / 0615
Page 81 of 139
Indoor Omni-directional Ceiling Mounted Antenna IXD-360VH03NN VH Pol, 360° 698-960/1710-2700MHz 4.0/4.8dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications Polarization Gain (dBi) Horizontal Beamwidth (°) VSWR Isolation between Ports (dB) IMD3 (2x33 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
698-960
1710-2700
698-790
790-960
3.5
4.0
1710-2170 Dual linear V&H 4.5 360 ≤2.0:1
≥18
2170-2700 4.8
≥20 ≤-140 50 50
Mechanical Specifications Parameters Dimensions, Diameter x Length (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Radome Material and Color Connector Type and Location Operational Temperature (°C) Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications Φ210x41 / Φ8.3x1.6 0.4 / 0.9 ABS, White 2 x N-Female, Bottom -30 to +45 Ceiling Mounted 205x205x210 / 8.1x8.1x8.3 0.6 / 1.3 Indoor
Product Picture
Connector Position & Installation Guide
698-960 1710-2700
698-960 1710-2700
N- F
N- F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0/ 0414
Page 82 of 139
Indoor Directional Wall Mounted Antenna IWH-090VR08NT VX Pol, 90° 790-960/1710-2700MHz 7.0/8.2dBi
Electrical Specifications Frequency Range (MHz) Parameters / Specifications Polarization Gain (dBi) Horizontal Beamwidth (°) Vertical Beamwidth (°) VSWR Isolation between Ports (dB) IMD3 (2x33 dBm Carrier) (dBc) Maximum Power per Port (W) Impedance (Ω)
790-960 790-960 Vertical 7.0 88 55
1710-2700 1710-2170
2300-2700 ±45°
8.0 75 44 ≤1.5:1
8.2 65 52 ≥25
/ ≤-140 50 50
Mechanical Specifications Parameters Dimensions, HxWxD (mm) / (in) Weight, w/o Mounting Kit (kg) / (lb) Radome Material and Color Connector Type and Location Operational Temperature (°C) Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 278x176x62 / 10.9x6.9x2.4 0.7 / 1.5 PVC, Light Grey 2 x N-Female, Bottom -30 to +45 Wall Mounted 338x221x80 / 13.3x8.7x3.1 0.8 / 1.8 Indoor
Product Picture
Connector Position & Installation Guide
790-960 1710-2700
1710-2700
N-F
N-F
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-0 / 1214
Page 83 of 139
RET System
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-2 / 0414
Page 84 of 139
RET System & Accessories 00-KX02A(xx)(xx=cable length in meter) .............................................................................................................................................. 86 CCU-003AG ......................................................................................................................................................................................... 87 RCU-003(IV) ........................................................................................................................................................................................ 88 BT-R4S2, BT-R5S2.............................................................................................................................................................................. 89
AISG Control Cable 00-KX02A(xx)(xx=cable length in meter)
5-core cable use for connection between AISG antenna line devices Compliance with AISG1.1 and AISG2.0 8-pin Circular connector type Weather resistance Supply in various length
Electrical Specifications Parameters
Specifications
Operating Voltage (V)
250
Operating Current @40°C (A)
5
Pulsating Voltage (V)
1200
Insulation Resistance (Ω)
>3x109
Contact Resistance (mΩ)
<5
Mechanical Specifications Parameters
Specifications
Cable Specification
2Cx0.32 + 3Cx0.75
Connector Type
2 x 8 pin circular connector, 1 Male + 1 Female
Operating Temperature
-40 to +85
Operating Humidity
≤95
Environmental Class
IP67
Ordering Information
AISG Cable Connector
Model Number
Length
00-KX02A(0.5) (m) / (in)
0.5 / 19.7
00-KX02A(1) (m) / (in)
1 / 39.4
00-KX02A(2) (m) / (in)
2 / 78.7
00-KX02A(3) (m) / (in)
3 / 118.1
00-KX02A(7) (m) / (in)
7 / 275.6
00-KX02A(5) (m) / (in)
5 / 196.9
00-KX02A(10) (m) / (in)
10 / 393.7
00-KX02A(15) (m) / (in)
15 / 590.6
00-KX02A(20) (m) / (in)
20 / 787.4
00-KX02A(25) (m) / (in)
15 / 984.3
00-KX02A(30) (m) / (in)
30 / 1,181.1
00-KX02A(40 ) (m) / (in)
40 / 1,574.8
00-KX02A(50 ) (m) / (in)
50 / 1,968.5
00-KX02A(60 ) (m) / (in)
60 / 2,362.2
00-KX02A(70 ) (m) / (in)
70 / 2,755.9
00-KX02A(80 ) (m) / (in)
80 / 3,149.6
00-KX02A(90) (m) / (in)
90 / 3,543.3
00-KX02A(100) (m) / (in)
100 / 3937
00-KX02A(110) (m) / (in)
110 / 4331
00-KX02A(120) (m) / (in)
120 / 4724
00-KX02A(130) (m) / (in)
130 / 5118
00-KX02A(140) (m) / (in)
140 / 5512
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0715
Male Connector
Female Connector
PIN assignment according AISG: 1 +13 V DC (+12 V DC nominal) 2 not connected 3 RS485 B 4 not connected 5 RS485 A 6 +29 V DC (+24 V DC nominal) 7 DC Return 8 not connected
Page 86 of 139
RET Central Control Unit Ver. 2.0 CCU-003AG
AISG v1.0 & v2.0 Compliance. Web-based application with built-in watchdog timer and supports USB 2.0 Self-diagnosable With overload, lightning surge, and short circuit protection Available in single or three AISG port model Compliant with CE, FCC and RoHS Standards Wall/Rack mountable
Electrical Specifications Parameters AISG Connectors Power Supply to AISG Devices
Specifications 3 x 8 pin connector, Female, conform to AISG Layer 1 28VDC / 1.7A, or 13VDC / 3.3A (Selectable using software)
Power Supply Input
-48 DC / 1.5A
Total Output Power
50W
LED Indicators
Alarm, Run, Power
Interface to RCU/TMA
RS-485 / Power Supply
Protocol to RCU/TMA
HDLC hex-code command set, conform to AISG Layer 2
Max. Number of RET*
Up to 24 RCUs (depending on cable configuration)
Max. Number of TMA*
Up to 6 TMAs (depending on cable configuration)
Interface for Remote Control Communication Ports Protocols to BTS Protection
Ethernet 10/100M adaptable RS-232, USB 2.0 TCP/IP, HTTP/HTML, SNMP, FTP, Telnet Built-in LPD, Over Load, Surge, Short Circuit
Mechanical Specifications Parameters Mounting Dimensions, HxWxD (mm) / (in) Weight Kit (kg) / (Ib) RS232 Connector
Specifications 1U, 19 inch rack-mount or Wall Mounted 44x220x185 / 1.7x8.6x7.3 1.5 / 3.3 9-PIN Mini-DIN PS/2
Housing Material and Color
Aluminium, Light Grey
Operating Temperature (°C)
0 to +55
Operating Humidity (%) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib)
<95 83x280x253 / 3.3x11.0x10.0 1.9 / 4.2
CCU System Structure
Note: Comba COMETS is a software tool that provides comprehensive features for OMC. For more information, please kindly refer to the COMETS datasheet
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-1-2 / 0815
Page 87 of 139
Remote Control Unit RCU-003(IV) 3GPP / AISG 2.0 Compliance Compact size and IP65 protection class
Electrical Specifications Parameters
Specifications
Connectors to CCU
8 pin connector, Male, conform to AISG 2.0
Connectors to RCU
8 pin connector, Female, conform to AISG 2.0
Power Supply (V)
+15 to +30 DC
Power Consumption (W)
<1(stand by); <10(operating)
Protocol to CCU/TMA
3GPP / AISG 2.0
Adjustment Time (s) (full range)
<60(typically, depending on antenna type)
Adjustment Cycles
>50,000
Mechanical Specifications Parameters
Specifications
Dimensions, HxWxD (mm) / (in)
124.5x44x41 / 4.9x1.7x1.6
Weight (kg) / (Ib)
0.25 / 0.6
Housing Material and Color
Aluminum, Light Grey
Operating Temperature (oC)
-40 to +60
Environment Class
IP65
Shipping Dimensions, HxWxD (mm) / (in)
145x52x48 / 5.7x2.0x1.9
Shipping Weight (kg) / (Ib)
0.3 / 0.7
Product View
Top View of RCU
Bottom View of RCU
PIN assignment according AISG: 1 not connected 2 not connected 3 RS485 B 4 not connected 5 RS485 A 6 +15 V ~ +30 V DC (+24 V DC nominal) 7 DC Return 8 not connected
Connector
Male Connector
Overview of RCU
Female Connector
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-3 / 0815
Page 88 of 139
Wide-band Smart Bias Tee BT-R4S2, BT-R5S2
Wide-band design covers 698-2700MHz range Provides DC voltage and remote control signals via RF feeder cable to TMA or to ALDs Complies with AISG 2.0 standard Low insertion loss and VSWR Provides lightning protection for BTS/Node B BT-R4S2 is commonly installed close to BTS/Node B and BT-R5S2 is installed on the tower close to VET antenna when no AISG TMA is in use BT-R5S2 photo shown for reference
Electrical Specifications Parameters
Specifications BT-R4S2
BT-R5S2 698-2700
Frequency Range (MHz) Insertion Losses (dB) VSWR Modem Carrier Frequency (MHz) Intermodulation Products (dBc) Power Handling (W) Current Capacitance (A) Operational Voltage (V) Model Impedance (Ω)
≤0.2 ≤1.2 2.176 ≤-153@2x43dBm 120 2.3 10-30 +24V(AISG port in, ANT port out) +24V(BTS/Node B port in, AISG port out) 50
Mechanical Specifications Parameters Dimensions,LxWxH (including connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (Ib) BTS/Node B Port Connector Type ANT Port DC/AISG Port Operational Temperature (°C) Operational Humidity (%) Environmental Class Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Lightning Protection
Specifications BT-R4S2
BT-R5S2 119x73x46 / 4.7x2.9x1.8 0.5 / 1.0
7/16 DIN-Female 7/16 DIN-Male 8-PIN Male Connector
7/16 DIN-Male 7/16 DIN-Female 8-PIN Female Connector
-40 to +65 ≤95 IP66 170x80x100 / 6.7x3.1x3.9 0.6 / 1.3 Comply with IEC 61000-4-5; 8kA, 8/20s
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 /0614
Page 89 of 139
RF Product
Page 90 of 139
RF Product Combiner......................................................................................................................................................................................................... 92 CM-AC2D-ODxA .................................................................................................................................................................................. 94 CM-AC2-ODx,CM-AC2D-ODx .............................................................................................................................................................. 95 CM-ACG3-ODx, CM-ACG3D-ODx ....................................................................................................................................................... 96 CM-ACKP4-OD1A................................................................................................................................................................................ 97 CM-ADWTY5-OD6 ............................................................................................................................................................................... 98 CM-AE2-ODx, CM-AE2D-ODx ............................................................................................................................................................. 99 CM-AG2-ODx, CM-AG2D-ODx .......................................................................................................................................................... 100 CM-DW2-ODxG, CM-DW2D-ODxG ................................................................................................................................................... 101 CM-DWY3-ODxA, CM-DWY3D-ODxA ............................................................................................................................................... 102 CM-FDW3-ODx, CM-FDW3D-ODx..................................................................................................................................................... 103 CM-FDWY4-ODx, CM-FDWY4D-ODx ................................................................................................................................................ 104 CM-FK2-ODx, CM-FK2D-ODx ........................................................................................................................................................... 105 CM-FKY3-ODx, CM-FKY3D-ODx ....................................................................................................................................................... 106 CM-KTY3-OD4 ................................................................................................................................................................................... 107 CM-KY2-ODxB, CM-KY2D-ODxB ...................................................................................................................................................... 108 CM-MY2-ODx, CM-MY2D-ODx .......................................................................................................................................................... 109 CM-PK2-ODx,CM-PK2D-ODx ............................................................................................................................................................ 110 CM-PPK3-ODx, CM-PPK3D-ODx ...................................................................................................................................................... 111 CM-W2D-ODx .................................................................................................................................................................................... 112
Hybrid Combiner........................................................................................................................................................................................... 113 COM-BD21ODN4............................................................................................................................................................................... 114 COM-BD21ODN8............................................................................................................................................................................... 115 COM-BD21ONN5............................................................................................................................................................................... 116
Directional Coupler....................................................................................................................................................................................... 117 DC-Rxx-OD500C(H)........................................................................................................................................................................... 118 DC-Rxx-ON300C(H)........................................................................................................................................................................... 120 Hybrid Coupler.............................................................................................................................................................................................. 122 HC-R4-OD200L, HC-R4-ON200L ....................................................................................................................................................... 123 HC-R-OD500L(XH) ............................................................................................................................................................................ 124 HC-R-ON300L(H)............................................................................................................................................................................... 125 Power Splitter ............................................................................................................................................................................................... 126 PS-R2-OD500C(XH), PS-R3-OD500C(XH), PS-R4-OD500C(XH) ..................................................................................................... 127 PS-R2-ON500C(H), PS-R3-ON500C(H), PS-R4-ON500C(H)............................................................................................................. 128 Filter .............................................................................................................................................................................................................. 129 FP-G70-OD01 .................................................................................................................................................................................... 130 Multiple Operator Combiner......................................................................................................................................................................... 131 POI-BD92ONY5 ................................................................................................................................................................................. 132 POI-CDG4IDN1.................................................................................................................................................................................. 134
Page 91 of 139
Combiner Model
Frequency (MHz)
Connector Type
Mounting
Dimension Single Unit (mm)
Dimension Dual Unit (mm)
CM-AC2D-ODxA
Band 1: 698-803 Band 2: 824-894
DIN-Female
Pole or Wall Mount
-
246x178x112
CM-AC2-ODx, CM-AC2D-ODx
Band 1: 698-798 Band 2: 817-894
DIN-Female
Pole or Wall Mount
246x178x56
246x178x114
CM-ACG3-ODx, CM-ACG3D-OD6x
Band 1: 703-803 Band 2: 825-880 Band 3: 898.4-960
DIN-Female
Pole or Wall Mount
249x200x58
249x200x118
CM-ACKP4-OD1A
Band 1: 698-787 Band 2: 806-894 Band 3: 1710-1755/2110-2155 Band 4: 1850-1995
DIN-Female
Pole or Wall Mount
216x183x56
-
CM-ADWTY5-OD6
Band 1: 678-960 Band 2: 1710-1880 Band 3: 1920-2170 Band 4: 2300-2390 Band 5: 2500-2690
DIN-Female
Pole or Wall Mount
260x240x50
-
CM-AE2-ODx, CM-AE2D-ODx
Band 1:790-862 Band 2:880-960
DIN-Female
Pole or Wall Mount
188x176x68
188x176x138
CM-AG2-ODx, CM-AG2D-ODx
Band 1:698-806 Band 2:880-960
DIN-Female
Pole or Wall Mount
201.5x151x58
201.5x151x118
CM-DW2-ODxG, CM-DW2D-ODxG
Band 1: 1710-1880 Band 2: 1920-2170
DIN-Female
Pole or Wall Mount
278x124x49
278x124x124
CM-DWY3-ODAx, CM-DWY3D-ODAx
Band 1: 1710-1880 Band 2: 1920-2170 Band 3: 2500-2690
DIN-Female
Pole or Wall Mount
240x210x50
240x210x103
CM-FDW3-ODx, CM-FDW3D-ODx
Band 1: 380-960 Band 2: 1710-1880 Band 3: 1920-2170
DIN-Female
Pole or Wall Mount
220x180x50.5
220x180x103
Page 92 of 139
Model
Frequency (MHz)
Connector Type
Mounting
Dimension Single Unit (mm)
Dimension Dual Unit (mm)
CM-FDWY4-ODx, CM-FDWY4D-ODx
Band 1: 380-960 Band 2: 1710-1880 Band 3: 1920-2170 Band 4: 2500-2690
DIN-Female
Pole or Wall Mount
240x210x50
240x210x103
CM-FK2-ODx, CM-FK2D-ODx
Band 1: 380-960 Band 2: 1710-2700
DIN-Female
Pole or Wall Mount
180x110x50
180x110x103
CM-FKY3-ODx, CM-FKY3D-ODx
Band 1: 380-960 Band 2: 1710-2170 Band 3: 2300-2690
DIN-Female
Pole or Wall Mount
187x158x50
187x158x102
CM-KTY3-OD4
Band 1: 1710-2170 Band 2: 2300-2390 Band 3: 2500-2690
DIN-Female
Pole or Wall Mount
146x138x44.5
-
CM-KY2-ODxB, CM-KY2D-ODxB
Band 1: 1710-2170 Band 2: 2300-2700
DIN-Female
Pole or Wall Mount
142x121x69
142x121x140
CM-MY2-ODx, CM-MY2D-ODx
Band 1: 806-960/1710-2170 Band 2: 2300-2700MHz
DIN-Female
Pole or Wall Mount
156x142x58
156x142x118
CM-PK2-ODx, CM-PK2D-ODx
Band 1: 1850-1910/1930-1990 Band 2: 1710-1755/2110-2155
DIN-Female
Pole or Wall Mount
167x143x45
167x143x97
CM-PPK3-ODx, CM-PPK3D-ODx
Band 1: 1850-1875/1930-1955 Band 2: 1885-1910/1965-1990 Band 3: 1710-1755/2110-2155
DIN-Female
Pole or Wall Mount
213x196x92
213x196x194
CM-W2D-ODx
Band 1: 2110-2130&1920-1940 Band 2: 2160-2170&1970-1980
DIN-Female
Pole or Wall Mount
-
230x150x90
Page 93 of 139
Outdoor Dual-Band Combiner CM-AC2D-ODxA Band 1:698-803MHz Band 2:824-894MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Double units
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
698-803
824-894
Insertion Loss (dB)
≤0.4
Isolation between Ports (dB)
≥60
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250 ≤-153@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) RF Connectors
Specifications 246x178x112 / 9.7x7.0x4.4 6.6 / 14.6 7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in)
465x365x250 / 18.3x14.4x9.8
Shipping Weight (kg) / (lb)
8.1 / 17.9
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
DC Bypass Optional No DC Bypass DC Bypass @698-803 DC Bypass @824-894 Full DC Pass
Port 3
Port 1 698-803
DC/AISG Bypass
Double units Model Number CM-AC2D-OD1A CM-AC2D-OD2A CM-AC2D-OD3A CM-AC2D-OD4A
Block Diagram
DC/AISG Bypass
Ordering Information
Port 2 824-894
Example: View of Single Unit CM-AC2-OD4A
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Page 94 of 139
Outdoor Dual-Band Combiner CM-AC2-ODx,CM-AC2D-ODx (x=1, 2, 3 or 4, Preconfigured DC-pass) Band 1:698-798MHz Band 2:817-894MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units Single unit for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
698-798
817-894
Insertion Loss (dB)
≤0.4
Isolation between Ports (dB)
≥60 ≥20
Return Loss (dB) Coupling Value at Com Port (dB)
43.5±2
Maximum Input Power per Port (W)
250 ≤-153@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
246x178x56 / 9.7x7.0x2.2
Double Units
246x178x114 / 9.7x7.0x4.5
Single Unit
3.2 / 7.1
Double Units
6.6 / 14.6
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
Single Unit
400x300x220 / 15.7x11.8x8.56
Double Units
465x365x250 / 18.3x14.4x9.8
Single Unit
4.9 / 10.8
Double Units
8.1 / 17.9
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Double units Model Number CM-AC2D-OD1 CM-AC2D-OD2 CM-AC2D-OD3 CM-AC2D-OD4
DC Bypass Optional No DC Bypass DC Bypass @698-798 DC Bypass @817-894 Full DC Pass
Port 3
Port 1 698-798
Couple port
DC/AISG Bypass
Single Unit Model Number CM-AC2-OD1 CM-AC2-OD2 CM-AC2-OD3 CM-AC2-OD4
Block Diagram
DC/AISG Bypass
Ordering Information
Port 2 817-894
Example: View of Single Unit CM-AC2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Page 95 of 139
Outdoor Tri-band Combiner CM-ACG3-ODx, CM-ACG3D-ODx Band 1:703-803MHz Band 2:825-880MHz Band 3:898.4-960MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications Insertion Loss (dB)
703-803
825-880
898.4-960
≤0.4
≤0.5
≤0.6
≥50
Isolation between Ports (dB) Out of Band Rejection (dB)
/
≥30@880-890MHz
/ ≥20
Return Loss (dB) Maximum Input Power per Port (W)
200 ≤-153@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
249x200x58 / 9.8x7.9x2.3
Double Units
249x200x118 / 9.8x7.9x4.6
Single Unit
4.0 / 8.8
Double Units
7.8 / 17.2
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65 ≤95
Operational Humidity (%) Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
495x340x205 / 19.5x13.4x8.1
Double Units
520x355x235 / 20.5x14.0x9.3
Single Unit
5.7 / 12.6
Double Units
Lightning Protection
Ordering Information
Block Diagram Port 4
No DC Bypass DC Bypass @703-803 DC Bypass @825-880 DC Bypass @898.4-960 Full DC Pass
DC/AISG Bypass
DC Bypass Optional
DC/AISG Bypass
Double units Model Number CM-ACG3D-OD1 CM-ACG3D-OD2 CM-ACG3D-OD3 CM-ACG3D-OD4 CM-ACG3D-OD6
DC/AISG Bypass
Single Unit Model Number CM-ACG3-OD1 CM-ACG3-OD2 CM-ACG3-OD3 CM-ACG3-OD4 CM-ACG3-OD6
9.7 / 21.4 Comply with IEC 61000-4-5; 8kA, 8/20s
Port1 703-803 -
Port2 825-880
Port3 898.4-960
Example: View of Single Unit CM-ACG3-OD6
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Page 96 of 139
Outdoor Quad-band Combiner CM-ACKP4-OD1A Band 1: 698-787MHz Band 2: 806-894MHz Band 3: 1710-1755/2110-2155MHz Band 4: 1850-1995MHz
Designed for feeder sharing and co-siting purpose No DC bypass High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Single unit
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
698-787
806-894
1710-1755/2110-2155
Insertion Loss (dB)
≤1.0
Pass Band Ripple (dB)
≤0.5
Coupling Value at COM Port (dB)
43.5±2
1850-1995
36±2 ≥60@698-787/806-894 ≥80@698-787/1710-2155 ≥80@806-894/1710-2155 ≥60@1710-1755&2110-2155/1850-1995
Isolation between Ports (dB)
≥18, typical 20
Return Loss (dB) Maximum Input Power per Port (W)
60
120 ≤-153@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) Color
Specifications 216x183x56 / 8.5x7.2x2.2 3.6 / 7.9 RAL9002, Grey White
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)(Including 1pc 2m grounded cable) Lightning Protection
464x364x184 / 18.3x14.3x7.2 5.9 / 13.0 Comply with IEC 61000-4-5; 8kA, 8/20s
Block Diagram Port 5 COM
Port 1 698-787
Coupling Port
Port 4 Port 2 Port 3 806-894 1710-1755 / 2110-2155 1850-1995
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 97 of 139
Outdoor Multi-band Combiner CM-ADWTY5-OD6 Band 1: 678-960MHz Band 2:1710-1880MHz Band 3:1920-2170MHz Band 4: 2300-2390MHz Band 5: 2500-2690MHz
Co-siting purpose for feeder sharing DC bypass@2600MHz system, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
678-960
1710-1880
1920-2170
≤0.2
Insertion Loss (dB)
2300-2390
2500-2690
≤0.4
Isolation between Ports(dB)
≥50
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250
Intermodulation Products
<-155 @2x43dBm
Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) ( mm) / (in)
260x240x50 / 9.4x8.3x2.0
Weight (including connectors and mounting bracket) (kg) / (lb)
4.0 / 8.8
Colors
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall mounted
Mounting Operating Temperature Range (°C)
-40 to +65 ≤95
Operational Humidity (%) Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in)
464x364x184 / 18.3x14.3x7.2
Shipping Weight (kg) / (lb)
5.3 / 11.7
Lightning Protection
IEC 61000-4-5; 8kA, 8/20s
Block Diagram
DC/AISG Bypass
Port 6
Port 1 678-960
Port 2 Port 3 Port 4 Port 5 1710-1880 1920-2170 2300-2390 2500-2690
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-3 / 0116
Page 98 of 139
Outdoor Dual-band Combiner CM-AE2-ODx, CM-AE2D-ODx (x= 1, 2, 3 or 4, Preconfigured DC-pass) Band 1:790-862MHz Band 2:880-960MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units Single unit photo for reference
Electrical Specifications
Pass Band Frequency Range (MHz) Parameters / Specifications
790-862
880-960
Insertion Loss (dB)
≤0.4
Isolation between Ports (dB)
≥50
Return Loss (dB)
≥18
Maximum Input Power per Port (W)
200 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors) (mm) / (in) Weight (including connectors) (kg) / (lb)
Single Unit
188x176x68 / 7.4x6.9x2.7
Double Units
188x176x138 / 7.4x6.9x5.4
Single Unit
2.4 / 5.3
Double Units
5.0 / 11.0
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
350x250x130 / 13.8x9.8x5.1
Double Units
350x250x200 / 13.8x9.8x7.9
Single Unit
2.9 / 6.4
Double Units
6.0 / 13.2
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single unit Model Number CM-AE2-OD1
Double units Model Number CM-AE2D-OD1
CM-AE2-OD2
CM-AE2D-OD2
DC Bypass @790-862
CM-AE2-OD3
CM-AE2D-OD3
DC Bypass @880-960
CM-AE2-OD4
CM-AE2D-OD4
Full DC Bypass
DC Bypass Optional
Port 3
Port 1 790-862
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 2 880-960
Example: View of Single Unit CM-AE2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0116
Page 99 of 139
Outdoor Dual Band Combiner CM-AG2-ODx, CM-AG2D-ODx(x=1, 2, 3 or 4, Preconfigured DC-pass) Band 1:698-806MHz Band 2:880-960MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
698-806
880-960
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥60
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250 ≤-153@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
201.5x151x58 / 7.9x5.9x2.3
Double Units
201.5x151x118 / 7.9x5.9x4.6
Single Unit
2.5 / 5.5
Double Units
5.2 / 11.5
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
400x250x200 / 15.7x9.8x7.9
Double Units
410x275x245 / 16.1x10.8x9.6
Single Unit
3.8 / 8.4
Double Units
6.3 / 13.9
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single Unit Model Number CM-AG2-OD1
Double Unit Model Number CM-AG2D-OD1
CM-AG2-OD2
CM-AG2D-OD2
DC Bypass @698-806
CM-AG2-OD3
CM-AG2D-OD3
DC Bypass @880-960
CM-AG2-OD4
CM-AG2D-OD4
Full DC Bypass
DC Bypass Optional Port 3
Port 1 698-806
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 2 880-960
Example: View of Single Unit CM-AG2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 100 of 139
Outdoor Dual Band Combiner CM-DW2-ODxG, CM-DW2D-ODxG (x=1, 2, 3 or 4, Preconfigured DC-pass) Band 1:1710-1880MHz Band 2:1920-2170MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1710-1880
1920-2170
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥50
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors) (mm) / (in) Weight (including connectors) (kg) / (lb)
Single Unit
210x124x49 / 7.6x4.9x1.9
Double Units
210x124x124 / 7.6x4.9x4.9
Single Unit
1.9 / 4.2
Double Units
3.9 / 8.6
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
Single Unit
415x200x130 / 16.3x7.9x5.1
Double Units
415x200x195 / 16.3x7.9x7.7
Single Unit
2.9 / 6.3
Double Units
5.4 / 11.9
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single Unit Model Number CM-DW2-OD1G
Double Unit Model Number CM-DW2D-OD1G
CM-DW2-OD2G
CM-DW2D-OD2G
DC Bypass @1710-1880
CM-DW2-OD3G
CM-DW2D-OD3G
DC Bypass @1920-2170
CM-DW2-OD4G
CM-DW2D-OD4G
Full DC Bypass
Port 3
DC Bypass Optional
Port1 1710-1880
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 2 1920-2170
Example: View of Single Unit CM-DW2-OD4G
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-0 / 0116
Page 101 of 139
Outdoor Tri-band Combiner CM-DWY3-ODxA, CM-DWY3D-ODxA(x=1, 2…or 6, Preconfigured DC-pass) Band 1:1710-1880MHz Band 2:1920-2170MHz Band 3:2500-2690MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1710-1880
1920-2170
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥50
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
2500-2690
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
240x210x50 / 9.4x8.3x2.0
Double Units
240x210x103 / 9.4x8.3x4.1
Single Unit
3.7 / 8.2
Double Units
7.0 / 15.4
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65 ≤95
Operational Humidity (%) Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
440x280x250 / 17.3x11.0x9.8
Double Units
505x340x225 / 19.8x13.4x8.8
Single Unit
5.4 / 11.9
Double Units
Lightning Protection
8.9 / 19.6 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram Port 4
Single Unit Model Number CM-DWY3-OD1A
Double Units Model Number CM-DWY3D-OD1A
CM-DWY3-OD2A
CM-DWY3D-OD2A
DC Bypass @1710-1880
CM-DWY3-OD3A
CM-DWY3D-OD3A
DC Bypass @1920-2170
CM-DWY3-OD4A
CM-DWY3D-OD4A
CM-DWY3-OD5A
CM-DWY3D-OD5A
CM-DWY3-OD6A
CM-DWY3D-OD6A
DC Bypass @2500-2690 DC Bypass @1710-1880 and @1920-2170 Full DC Bypass
DC Bypass Optional
DC/AISG Bypass
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 1 1710-1880
Port2 1920-2170
Port3 2500-2690
Example: View of Single Unit CM-DWY3-OD6A
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-0 / 0116
Page 102 of 139
Outdoor Tri-band Combiner CM-FDW3-ODx, CM-FDW3D-ODx (x=1, 2…or 6, Preconfigured DC-pass) Band 1:380-960MHz Band 2:1710-1880MHz Band 3:1920-2170MHz Ultra wideband design for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
380-960
1710-1880
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥50
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250
1920-2170
≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
220x180x50.5 / 8.7x7.1x2.0
Double Units
220x180x103 / 8.7x7.1x4.1
Single Unit
3.0 / 6.6
Double Units
5.8 / 12.8
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
464x364x184 / 18.3x14.3x7.2
Double Units
465x365x250 / 18.3x14.4x9.8
Single Unit
4.6 / 10.1
Double Units
Lightning Protection
7.4 / 16.3 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single Unit Model Number CM-FDW3-OD1
Double Units Model Number CM-FDW3D-OD1
CM-FDW3-OD2
CM-FDW3D-OD2
DC Bypass @380-960
CM-FDW3-OD3
CM-FDW3D-OD3
DC Bypass @1710-1880
CM-FDW3-OD4
CM-FDW3D-OD4
DC Bypass @1920-2170
CM-FDW3-OD6
CM-FDW3D-OD6
Full DC Bypass
Port 4
DC Bypass Optional
Port 1 380-960
Port2 1710-1880
DC/AISG Bypass
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port3 1920-2170
Example: View of Single Unit CM-FDW3-OD6
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-1 / 0116
Page 103 of 139
Outdoor Quad-Band Combiner CM-FDWY4-ODx, CM-FDWY4D-ODx(x=1, 2…or 8, Preconfigured DC-pass) Band 1:380-960MHz Band 2:1710-1880MHz Band 3:1920-2170MHz Band 4:2500-2690MHz
Ultra wideband design for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
380-960
1710-1880
1920-2170
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥50
Return Loss(dB)
≥20
Maximum Input Power per Port (W)
250
2500-2690
≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in)
Single Unit
240x210x50 / 9.4x8.3x2.0
Double Units
240x210x103 / 9.4x8.3x4.1
Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
3.9 / 8.6
Double Units
7.8 / 17.2
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range(°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
440x290x250 / 17.3x11.4x9.8
Double Units
520x355x250 / 20.5x14.0x9.8
Single Unit
5.2 / 11.5
Double Units
Lightning Protection
9.6 / 21.2 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram Port 5
Single Unit Model Number CM-FDWY4-OD1
Double Units Model Number CM-FDWY4D-OD1
CM-FDWY4-OD2
CM-FDWY4D-OD2
DC Bypass @380-960
CM-FDWY4-OD3
CM-FDWY4D-OD3
DC Bypass @1710-1880
CM-FDWY4-OD4
CM-FDWY4D-OD4
DC Bypass @1920-2170
CM-FDWY4-OD5
CM-FDWY4D-OD5
DC Bypass @2500-2690
CM-FDWY4-OD8
CM-FDWY4D-OD8
Full DC Bypass
DC Bypass Optional
Port 1 380-960
Port2 1710-1880
Port3 1920-2170
DC/AISG Bypass
DC/AISG Bypass
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 4 2500-2690
Example: View of Single Unit CM-FDWY4-OD8
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-3 / 0116
Page 104 of 139
Outdoor Dual-band Combiner CM-FK2-ODx, CM-FK2D-ODx (x=1, 2, 3 or 4, Preconfigured DC-pass) Band 1:380-960MHz Band 2:1710-2700MHz Ultra wideband design for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units Single unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz)
Parameters / Specifications
380-960
1710-2700
Insertion Loss (dB)
≤0.2
Isolation Between Ports (dB)
≥60
Return Loss (dB)
≥20
Maximum Input Power Per Port (W)
300 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
180x110x50 / 7.1x4.3x2.0
Double Units
180x110x103 / 7.1x4.3x4.1
Single Unit
2.0 / 4.4
Double Units
3.9 / 8.6
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm Pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environment Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
Single Unit
405x226x210 / 15.9x8.9x8.3
Double Units
405x225x275 / 15.9x8.9x10.8
Single Unit
3.0 / 6.6
Double Units
Lightning Protection
4.9 / 10.8 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram Port 3
Single Unit Model Number CM-FK2-OD1
Double Units Model Number CM-FK2D-OD1
CM-FK2-OD2
CM-FK2D-OD2
DC Bypass @380-960
CM-FK2-OD3
CM-FK2D-OD3
DC Bypass @1710-2700
CM-FK2-OD4
CM-FK2D-OD4
Full DC Bypass
DC Bypass Optional
Port 1 380-960
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 2 1710-2700
Example: View of Single Unit CM-FK2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-5 / 0116
Page 105 of 139
Outdoor Tri-band Combiner CM-FKY3-ODx, CM-FKY3D-ODx (x=1, 2…or 6, Preconfigured DC-pass) Band 1:380-960MHz Band 2:1710-2170MHz Band 3:2300-2690MHz Ultra wideband design for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Single Unit photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
380-960
1710-2170
2300-2690
≤0.3 ≥60@380-960 / 1710-2170MHz ≥60@380-960 / 2300-2690MHz ≥55@1710-2170 / 2300-2690MHz ≥20
Insertion Loss (dB) Isolation between Ports (dB) Return Loss (dB) Maximum Input Power per Port (W)
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
187x158x50 / 7.4x6.2x2.0
Double Units
187x158x102 / 7.4x6.2x4.0
Single Unit
2.6 / 5.7
Double Units
5.2 / 11.5
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
Single Unit
392x247x185 / 15.4x9.7x7.3
Double Units
400x300x220 / 15.7x11.8x8.7
Single Unit
3.5 / 7.7
Double Units
Lightning Protection
6.1 / 13.4 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single Unit Model Number CM-FKY3-OD1
Double Units Model Number CM-FKY3D-OD1
CM-FKY3-OD2
CM-FKY3D-OD2
DC Bypass @380-960
CM-FKY3-OD3
CM-FKY3D-OD3
DC Bypass @1710-2170
CM-FKY3-OD4
CM-FKY3D-OD4
DC Bypass @2300-2690
CM-FKY3-OD6
CM-FKY3D-OD6
Full DC Bypass
Port 4
DC Bypass Optional
Port 1 380-960 -
Port2 1710-2170
DC/AISG Bypass
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 3 2300-2690
Example: View of Single Unit CM-FKY3-OD6
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0116
Page 106 of 139
Outdoor Tri-band Combiner CM-KTY3-OD4 Band 1:1710-2170MHz Band 2:2300-2390MHz Band 3:2500-2690MHz Co-siting purpose for feeder sharing DC bypass@2500-2690MHz, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1710-2170
2300-2390
Insertion Loss (dB)
≤0.4
Isolation between Ports (dB)
≥70
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
2500-2690
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) Color
Specifications 146x138x44.5 / 5.7x5.4x1.8 1.9 / 4.2 Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in)
345x215x220 / 13.6x8.5x8.7
Shipping Weight (kg) / (lb)
2.8 / 6.2
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Block Diagram
DC/AISG Bypass
Port 4
Port1 1710-2170
Port2 2300-2390
Port3 2500-2690
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-4 / 0116
Page 107 of 139
Outdoor Dual-band Combiner CM-KY2-ODxB, CM-KY2D-ODxB (x=1, 2…or 4, Preconfigured DC-pass) Band 1:1710-2170MHz Band 2:2300-2700MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation-minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1710-2170
2300-2700
Insertion Loss (dB)
≤0.3
Isolation between Ports (dB)
≥70
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
300 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors) (mm) / (in) Weight (including connectors and mounting bracke) (kg) / (lb)
Single Unit
142x121x69 / 5.6x4.8x2.7
Double Units
142x121x140 / 5.6x4.8x5.5
Single Unit
1.7 / 3.7
Double Units
3.4 / 7.5
Color
Light Grey
RF Connectors Mounting Operating Temperature Range (°C)
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted -40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
350x195x140 / 13.8x7.7x5.5
Double Units
350x195x210 / 13.8x7.7x8.3
Single Unit
2.8 / 6.2
Double Units
4.6 / 10.1
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram
Single Unit Model Number CM-KY2-OD1B
Double Units Model Number CM-KY2D-OD1B
CM-KY2-OD2B
CM-KY2D-OD2B
DC Bypass @1710-2170
CM-KY2-OD3B
CM-KY2D-OD3B
DC Bypass @2300-2700
CM-KY2-OD4B
CM-KY2D-OD4B
Full DC Bypass
DC Bypass Optional
Port 3
Port 1 1710-2170
DC/AISG Bypass
DC/AISG Bypass
No DC Bypass
Port 2 2300-2700
Example: View of Single CM-KY2-OD4B
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-9 / 0116
Page 108 of 139
Outdoor Dual-band Combiner CM-MY2-ODx, CM-MY2D-ODx (x=2 or 4, Preconfigured DC-pass) Band 1:806-960/1710-2170MHz Band 2:2300-2700MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units Photo for reference
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
806-960/1710-2170
2300-2700
Insertion Loss (dB)
≤0.3
Isolation Between Ports (dB)
≥70
Return Loss (dB)
≥20
Maximum Input Power Per Port (W)
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in)
Single Unit
156x142x58 / 6.1x5.6x2.3
Double Units
156x142x118 / 6.1x5.6x4.6
Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
2.4 / 5.3
Double Units
4.7 / 10.4
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm Pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environment Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
365x265x230 / 14.4x10.4x9.1
Double Units
405x225x275 / 16.0x8.9x10.8
Single Unit
3.4 / 7.5
Double Units
Lightning Protection
5.7 / 12.7 Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram Port 3
DC Bypass Optional DC Bypass @806-960/1710-2170 Full DC Bypass
Port 1 806-960/1710-2170
DC/AISG Bypass
Double units Model Number CM-MY2D-OD2 CM-MY2D-OD4
DC/AISG Bypass
Single unit Model Number CM-MY2-OD2 CM-MY2-OD4
Port 2 2300-2700
Example: View of Single Unit CM-MY2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control:3-0-5 / 0116
Page 109 of 139
Outdoor Dual-band Combiner CM-PK2-ODx, CM-PK2D-ODx(x=1, 2, 3 or 4, Preconfigured DC-pass) Band 1: 1850-1910/1930-1990MHz Band 2: 1710-1755/2110-2155MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1710-1755/2110-2155
1850-1910/1930-1990 ≤0.3
Insertion Loss (dB)
≤0.2
Isolation between Bands (dB)
≥50
Return Loss (dB)
≥20
Maximum Input Power per Port (W)
250 ≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in)
Single Unit
167x143x45 / 6.6x5.6x1.8
Double Units
167x143x97 / 6.6x5.6x3.8
Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
2.1 / 4.6
Double Units
4.3 / 9.5
Color
Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65 ≤95
Operational Humidity (%) Environmental Class
IP67
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
Single Unit
395x300x215 / 15.6x11.8x8.5
Double Units
395x300x265 / 15.6x11.8x10.4
Single Unit
4.5 / 9.9
Double Units
6.9 / 15.2
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
CM-PK2-OD2
CM-PK2D-OD2
CM-PK2-OD3
CM-PK2D-OD3
CM-PK2-OD4
CM-PK2D-OD4
Block Diagram Port 3
DC Bypass Optional No DC Bypass DC Bypass @18501910/1930-1990 DC Bypass @17101755/2110-2155 Full DC Pass
DC/AISG Bypass
Double units Model Number CM-PK2D-OD1
DC/AISG Bypass
Single Unit Model Number CM-PK2-OD1
Port 1 Port 2 1850-1910/1930-1990 1710-1755/2110-2155
Example: View of Single Unit CM-PK2-OD4 © Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-1 / 0116
Page 110 of 139
Outdoor Tri-band Combiner CM-PPK3-ODx, CM-PPK3D-ODx (x=1, 2…or 6, Preconfigured DC-pass) Band 1: 1850-1875/1930-1955MHz Band 2: 1885-1910/1965-1990MHz Band 3: 1710-1755/2110-2155MHz Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG Devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Available as a single unit or double units
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications Insertion Loss (dB) Rejection (dB)
1850-1875/1930-1955
1885-1910/1965-1990
1710-1755/2110-2155
≤0.7 ≥30@1885-1910/1965-1990 ≥50@1710-1755/2110-2155
≤0.7 ≥30@1850-1875/1930-1955 ≥50@1710-1755/2110-2155 ≥20
≤0.3 ≥50@1850-1875/1930-1955 ≥50@1885-1910/1965-1990
100
200
Return Loss (dB) Maximum Input Power per Port (W)
100
≤-155@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb)
Single Unit
213x196x92 / 8.4x7.7x3.6
Double Units
213x196x194 / 8.4x7.7x7.6
Single Unit
5.0 / 11.0
Double Units
10.5 / 23.1
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range(°C)
-40 to +65 ≤95
Operational Humidity (%) Environmental Class Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib)
IP67 Single Unit
385x325x150 / 15.2x12.8x5.9
Double Units
505x335x375 / 19.9x13.2x14.8
Single Unit
5.6 / 12.3
Double Units
11.5 / 25.4
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information
Block Diagram Port 4
No DC Bypass DC Bypass @1850-1875/1930-1955 DC Bypass @1885-1910/1965-1990 DC Bypass @1710-1755/2110-2155 Full DC Bypass
DC/AISG Bypass
DC Bypass Optional
DC/AISG Bypass
Double Units Model Number CM-PPK3D-OD1 CM-PPK3D-OD2 CM-PPK3D-OD3 CM-PPK3D-OD4 CM-PPK3D-OD6
DC/AISG Bypass
Single Unit Model Number CM-PPK3-OD1 CM-PPK3-OD2 CM-PPK3-OD3 CM-PPK3-OD4 CM-PPK3-OD6
Port1 1850-1875/1930-1955
Port2 1885-1910/1965-1990
Port3 1710-1755/2110-2155
Example: View of Single Unit CM-PPK3-OD6 © Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Page 111 of 139
Outdoor Dual-band Combiner CM-W2D-ODx (x=1, 2…or 4, Preconfigured DC-pass) Band 1:2110-2130&1920-1940MHz Band 2:2160-2170&1970-1980MHz
Co-siting purpose for feeder sharing Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices High isolation – minimizes interference High power handling and low loss – maximizes system performance Built-in lightning protection Double units
Electrical Specifications Pass Band Frequency Range (MHz) Parameters / Specifications
1920-1940/2110-2130
1970-1980/2160-2170
Insertion Loss (dB)
0.4
Isolation between Ports (dB)
≥40
Return Loss (dB)
≥18
Maximum Input Power per Port (W)
300 -160@2x43dBm
Intermodulation Products (in RX band)(dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors) (mm) / (in) Weight (including connectors) (kg) / (lb) Color
Specifications 230x150x90 / 9.1x5.9x3.5 3.6 / 7.9 Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole)
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
95
Environment Class
IP67
Shipping Dimensions, LxWxH (mm) / (in)
335x299x203 / 13.2x11.8x8.0
Shipping Weight (kg) / (Ib)
4.6 / 10.1
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
Ordering Information DC Bypass Optional
Port 3
DC Pass @1920-1940/2110-2130
CM-W2D-OD3
DC Pass @1970-1980/2160-2170
CM-W2D-OD4
Full DC Pass
DC/AISG Bypass
No DC Pass
CM-W2D-OD2
DC/AISG Bypass
Double units Model Number CM-W2D-OD1
Block Diagram
Port 1 Port 2 1920-1940/2110-2130 1970-1980/2160-2170
Example: View of Single Unit CM-W2-OD4
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Page 112 of 139
Hybrid Combiner Model
Frequency (MHz)
Connector Type
Mounting
Power Handling (W)
Dimension (mm)
COM-BD21ODN4
698-2700
DIN-Female
Pole or Wall Mount
100
270x190x87
COM-BD21ODN8
698-2700
DIN-Female
Pole or Wall Mount
50
150x172x46
COM-BD21ONN5
698-2700
N-Female
Pole or Wall Mount
50
150x172x46
Page 113 of 139
2:1 Hybrid Combiner COM-BD21ODN4
Wideband covering 698-2700MHz High input power handling capability Low insertion loss and VSWR, high isolation Integrating two operators’ services into an existing in-building antenna distribution system Terminated two low PIM performance cable load
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
698-2700 3.10.6@698-806MHz 3.10.5@806-2700MHz ≥30*@806-960MHz ≥23*@2170-2700MHz ≥25*@ Others ≥18
Coupling Attenuation (dB) Isolation between Ports (dB) Return Loss (dB)
≤-155@2x43dBm
Intermodulation Products (dBc) Maximum Input Power per Port (W)
100
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) Color
Specifications 270x190x87 / 10.6x7.5x3.4 6.4 / 14.1 Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP66
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (lb) * Valid if all ports are terminated with 50Ω load
440x290x250 / 17.3x11.4x9.8 8.0 / 17.6
Block Diagram 1 Output Load HC
* 2 Input DC/AISG Bypass
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-4 / 0116
Page 114 of 139
2:1 Hybrid Combiner COM-BD21ODN8
Wideband covering 698-2700MHz Low insertion loss and VSWR, high isolation Integrating two operators’ services into an existing in-building antenna distribution system. Terminated with low PIM performance cable load
Electrical Specifications Frequency Range (MHz) Parameters / Specifications 698-2700 3.10.6@698-806 MHz 3.10.5@806-2700 MHz ≥25*
Coupling Attenuation (dB) Isolation between Ports (dB)
≥18,typical 20
Return Loss (dB)
≤-153@2x43dBm
Intermodulation Products (dBc) Maximum Input Power per Port (W)
50
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) Color
Specifications 150x172x46 / 6.0x6.8x1.8 2.5 / 5.5 Light Grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class
IP66
Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib) * Valid if all ports are terminated with 50Ω load
405x226x220 / 16.0x8.9x8.7 3.6 / 7.9
Block Diagram 1 Output Load HC
* 2 Input DC/AISG Bypass
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 115 of 139
2:1 Hybrid Combiner COM-BD21ONN5
Wideband covering 698-2700MHz Low insertion loss and VSWR, high isolation Integrating two operators’ services into an existing in-building antenna distribution system Terminated with low PIM performance cable load
Electrical Specifications Frequency Range (MHz) Parameters / Specifications 698-2700 3.10.6@698-806 MHz 3.10.5@806-2700 MHz ≥25*
Coupling Attenuation (dB) Isolation between Ports (dB)
≥18,typical 20
Return Loss (dB)
≤-153@2x43dBm
Intermodulation Products (dBc) Maximum Input Power per Port (W)
50
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (including connectors and mounting bracket) (kg) / (lb) Color
Specifications 150x172x46 / 6.0x6.8x1.8 2.3 / 5.1 Light Grey
RF Connectors
N-Female Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Mounting Operating Temperature Range (°C)
-40 to +65
Operational Humidity (%)
≤95
Environmental Class Shipping Dimensions, LxWxH (mm) / (in)
IP66
Shipping Weight (kg) / (Ib)
405x226x220 / 16.0x8.9x8.7 3.4 / 7.5
* Valid if all ports are terminated with 50Ω load
Block Diagram 1 Output Load HC
* 2 Input DC/AISG Bypass
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 2-0-0 / 0116
Page 116 of 139
Directional Coupler Model
Frequency (MHz)
Connector Type
Coupling Factor (dB)
Power Handling (W)
PIM (dBc) @2x43dbm
Dimension (mm)
DC-Rxx-OD500C(H)
698-2700
DIN-Female
5, 6, 7, 8, 10, 13, 15, 20, 30, 40
500
-150
164x43x35
DC-Rxx-ON300C(H)
698-2700
N-Female
5, 6, 7, 8, 10, 13, 15, 20, 30, 40
300
-150
158x61x21.5
Page 117 of 139
Wide-band Directional Coupler DC-Rxx-OD500C(H) (xx=05, 06…or 40, Preconfigured Coupling Value) 5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, D-Female, 500W
Wide-band design covers 698-2700MHz range Low main line loss with high reliability. Suitable for both indoor and outdoor applications.
Electrical Specifications Parameters
DC-R05OD500C(H)
DC-R06OD500C(H)
Frequency Range (MHz) Coupling Value (dB)
Specifications DC-R07OD500C(H)
DC-R08OD500C(H)
DC-R10OD500C(H)
698-2700 5
6
7
8
10
Coupling Tolerance (dB)
±0.8
±0.8
±0.8
±0.8
±0.8
Main Line Loss (dB)
≤2.1
≤1.6
≤1.4
≤1.2
≤0.7
Isolation (dB)
≥25
≥26
≥27
≥28
≥30
Input Port VSWR Intermodulation Products (dBc)
≤1.25 ≤-150@2x43dBm
Input Average Power, Maximum (W)
500
Peak Power, Maximum (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (Ib) Connector Type Operational Temperature (°C) Operational Humidity (%) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 164x64x35 / 6.5x2.5x1.4 0.75 / 1.65 DIN-Female -40 to +60 ≤95 180x80x45 / 7.1x3.1x1.8 0.8 / 1.8 IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0715
Page 118 of 139
Wide-band Directional Coupler DC-Rxx-OD500C(H) (xx=05, 06…or 40, Preconfigured Coupling Value) 5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, D-Female, 500W
Wide-band design covers 698-2700MHz range Low main line loss with high reliability. Suitable for both indoor and outdoor applications.
Electrical Specifications Specifications Parameters
DC-R13OD500C(H)
DC-R15OD500C(H)
Frequency Range (MHz)
DC-R20OD500C(H)
DC-R30OD500C(H)
DC-R40OD500C(H)
698-2700
Coupling Value (dB)
13
15
20
30
40
Coupling Tolerance (dB)
±1
±1
±1.2
±1.5
±1.5
Main Line Loss (dB)
≤0.5
≤0.4
≤0.3
≤0.2
≤0.2
Isolation (dB)
≥33
≥35
≥35
≥45
≥55
Input Port VSWR Intermodulation Products (dBc)
≤1.25 ≤-150@2x43dBm
Input Average Power, Maximum (W)
500
Peak Power, Maximum (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (Ib) Connector Type Operational Temperature (°C) Operational Humidity (%) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 164x64x35 / 6.5x2.5x1.4 0.75 / 1.65 DIN-Female -40 to +60 ≤95 180x80x45 / 7.1x3.1x1.8 0.8 / 1.8 IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0715
Page 119 of 139
Wide-band Directional Coupler DC-Rxx-ON300C(H) (xx=05, 06…or 40, Preconfigured Coupling Value) 5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, N-Female, 300W
Wide-band design covers 698-2700MHz range Low main line loss with high reliability. Suitable for both indoor and outdoor applications.
Electrical Specifications Parameters
DC-R05ON300C(H)
DC-R06ON300C(H)
Frequency Range (MHz) Coupling Value (dB)
Specifications DC-R07ON300C(H)
DC-R08ON300C(H)
DC-R10ON300C(H)
698-2700 5
6
7
8
10
Coupling Tolerance (dB)
±0.8
±0.8
±0.8
±0.8
±0.8
Main Line Loss (dB)
≤2.1
≤1.6
≤1.4
≤1.2
≤0.7
Isolation (dB)
≥25
≥26
≥27
≥28
≥30
Input Port VSWR Intermodulation Products (dBc)
≤1.25 ≤-150@2x43dBm
Input Average Power, Maximum (W)
300
Peak Power , Maximum (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (Ib) Connector Type Operational Temperature (°C) Operational Humidity (%) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 158x61x21.5 / 6.2x2.4x0.8 0.3 / 0.7 N-Female -40 to +60 ≤95 180x75x30 / 7.1x3.0x1.2 0.4 / 0.9 IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-5 / 0715
Page 120 of 139
Wide-band Directional Coupler DC-Rxx-ON300C(H) (xx=05, 06…or 40, Preconfigured Coupling Value) 5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, N-Female, 300W
Wide-band design covers 698-2700MHz range Low main line loss with high reliability. Suitable for both indoor and outdoor applications.
Electrical Specifications Parameters
DC-R13ON300C(H)
DC-R15ON300C(H)
Frequency Range (MHz)
Specifications DC-R20ON300C(H)
DC-R30ON300C(H)
DC-R40ON300C(H)
698-2700
Coupling Value (dB)
13
15
20
30
40
Coupling Tolerance (dB)
±1
±1
±1.2
±1.5
±1.5
Main Line Loss (dB)
≤0.5
≤0.4
≤0.3
≤0.2
≤0.2
Isolation (dB)
≥33
≥35
≥40
≥45
≥ 55
Input Port VSWR Intermodulation Products (dBc)
≤1.25 ≤-150@2x43dBm
Input Average Power, Maximum (W)
300
Peak Power (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (Ib) Connector Type Operational Temperature (°C) Operational Humidity (%) Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class
Specifications 158x61x21.5 / 6.2x2.4x0.8 0.3 / 0.7 N-Female -40 to +60 ≤95 180x75x30 / 7.1x3.0x1.2 0.4 / 0.9 IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-5 / 0715
Page 121 of 139
Hybrid Coupler Model
Frequency (MHz)
Connector Type
Power Handling (W)
Dimension (mm)
HC-R4-OD200L, HC-R4-ON200L
698-2700
DIN-Female N-Female
200
250x100x60 250x100x54
HC-R-OD500L(XH)
698-2700
DIN-Female
500
127x86x37
HC-R-ON300L(H)
698-2700
N-Female
300
127x80x24.2
Page 122 of 139
4 IN 4 OUT Wideband Hybrid Coupler HC-R4-OD200L, HC-R4-ON200L 698-2700MHz, Din-Female / N-Female, 200W
Compact and cost effective design for same band combining of 698-2700MHz signals High inter-band isolation and input power handling Low insertion loss The use of fewer than 4 inputs or outputs is possible. Any unused input&output ports have to be terminated with low-power 50Ω loads Suitable for indoor or outdoor applications Din type photo for reference
Electrical Specifications Specifications
Parameters
HC-R4-OD200L
HC-R4-ON200L
Frequency Range (MHz)
698-2700
Input Average Power, Maximum (W)
200
Peak Power (W)
800
Insertion Loss (dB)
≤0.5
Coupling Value (dB)
6.0±0.6 ≥23* ≤1.22@698-2500MHz ≤1.30@2500-2700MHz ≤-150@2x43dBm
Isolation between Ports (dB) VSWR Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors) (mm) / (in) Weight (including connectors) (kg) / (lb) Connector Type
Specifications 250x100x60 / 9.8x3.9x2.4 2.2 / 4.9
1.6 / 3.5
8xDIN-Female
8xN-Female
Operating Temperature Range (°C)
-40 to +60 ≤95
Operational Humidity (%) Environmental Class Shipping Dimensions LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
250x100x54 / 9.8x3.9x2.1
IP65 One unit
285x225x105 / 11.2x8.9x4.1
Ten units
580x480x330 / 22.8x18.9x13.0
One unit
Ten units * Valid if all ports are terminated with 50Ω load
2.6 / 5.7
2.6 / 5.7
24.8 / 54.7
24.8 / 54.7
Outline Drawing
Din type connector © Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-3 / 0116
N type connector
Page 123 of 139
2 IN 2 OUT Wideband Hybrid Coupler HC-R-OD500L(XH) 698-2700MHz, Din-Female, 500W
Wideband covering 698-2700MHz High input power handling capability Low insertion loss and VSWR, high isolation Integrating two operators’ services into an existing in-building antenna distribution system
Electrical Specifications Parameters Frequency Range (MHz)
Specifications 698-2700
Input Average Power, Maximum (W)
500
Peak Power (W)
1000
Insertion Loss (dB)
≤0.1
Coupling Value (dB)
3.1
Coupling Tolerance (dB)
±0.5
Isolation Between Ports (dB)
≥25*
VSWR Intermodulation Products(dBc) Impedance (Ω)
≤1.25* ≤-153@2x43dBm 50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (lb) Connector Type Operating Temperature Range (°C) Operational Humidity (%) Shipping Dimensions, LxWxH (mm) / (in) Shipping Weight (kg) / (Ib) Environmental Class * Valid if all ports are terminated with 50Ω load
Specifications 127x86x37 / 5.0x3.4x1.5 0.9 / 2.0 7/16 DIN-Female -40 to +60 ≤95 170x100x40 / 6.7x3.9x1.6 1.1 / 2.4 IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0715
Page 124 of 139
2 IN 2 OUT Wideband Hybrid Coupler HC-R-ON300L(H) 698-2700MHz, N-Female, 300W
Wideband covering 698-2700MHz High input power handling capability Low insertion loss and VSWR, high isolation Integrating two operators’ services into an existing in-building antenna distribution system
Electrical Specifications Parameters
Specifications 698-2700
Frequency Range (MHz) Input Average Power, Maximum (W)
300
Peak Power (W)
1000
Insertion Loss (dB)
≤0.1
Coupling Value (dB)
3.1
Coupling Tolerance (dB)
±0.5 ≥25*
Isolation Between Ports (dB)
≤1.25*
VSWR
≤-150@2x43dBm
Intermodulation Products (dBc) Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (including connectors) (mm) / (in) Weight (including connectors) (kg) / (lb)
Specifications 127x80x24.2 / 5.0x3.1x1.0 0.4 / 0.9
Connector Type
N-Female
Operating Temperature Range (°C)
-40 to +60 ≤95
Operational Humidity (%) Shipping Dimensions, LxWxH (mm) / (in)
163x87x35 / 6.4x3.4x1.4
Shipping Weight (kg) / (Ib)
0.42 / 0.9
Environmental Class * Valid if all ports are terminated with 50Ω load
IP65
Outline Drawing
IN
IN
OUT
OUT
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0715
Page 125 of 139
Power Splitter Model
Frequency (MHz)
Type
Connector Type
Power Handling (W)
2 way PS-R2-OD500C(XH), PS-R3-OD500C(XH), PS-R4-OD500C(XH)
PS-R2-ON500C(H), PS-R3-ON500C(H), PS-R4-ON500C(H)
698-2700
698-2700
3 way
Dimension (mm) 229.9x81.4x38.0
DIN-Female
500
248.1x81.4x38.0
4 way
270.6x80.2x38.0
2 way
214.8x60.6x25.0
3 way 4 way
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-2 / 0414
N-Female
500
269.4x60.6x25.0 270.6x60.6x42.8
Page 126 of 139
Wideband Reactive Power Splitter PS-R2-OD500C(XH), PS-R3-OD500C(XH), PS-R4-OD500C(XH) 2/3/4way, 698-2700MHz, Din-Female, 500W
Wide-band design covers 698-2700MHz range High input power handling capability Low loss, flat response and even output High reliability
Electrical Specifications Specifications Parameters
PS-R2-OD500C(XH) 2 Ways
Frequency (MHz) Splitting Loss (dB)
PS-R3-OD500C(XH)
PS-R4-OD500C(XH)
3 Ways
4 Ways
698-2700 3.0
Insertion Loss (dB)
4.8
6.0
≤0.3
Input Port VSWR
≤1.22
Intermodulation Products (dBc)
≤-153@2x43dBm
Input Average Power, Maximum (W)
500
Peak Power, Maximum (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions LxWxH (mm) / (in) Weight (kg) / (lb)
Specifications 2 Ways
3 Ways
4 Ways
229.9x81.4x38.0 / 9.1x3.2x1.5
248.1x81.4x38.0 / 9.8x3.2x1.5
270.6x80.2x38.0 / 10.7x3.2x1.5
1.1 / 2.4
1.2 / 2.6
1.3 / 2.9
Connector Type
7/16 DIN-Female
Operational Temperature (°C)
-40 to +60 ≤95
Operational Humidity (%) Shipping Dimensions LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
239.9x86.4x43.0 / 9.4x3.4x1.7
258.1x86.4x43 / 10.2x3.4x1.7
280.6x85.2x43 / 11.0x3.4x1.7
1.2 / 2.6
1.3 / 2.9
1.4 / 3.1
Environmental Class
IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-3 / 0414
Page 127 of 139
Wideband Reactive Power Splitter PS-R2-ON500C(H), PS-R3-ON500C(H), PS-R4-ON500C(H) 2/3/4way, 698-2700MHz, N-Female, 500W
Wide-band design covers 698-2700MHz range High input power handling capability Low loss, flat response and even output High reliability
Electrical Specifications Specifications Parameters
PS-R2-ON500C(H) 2 Ways
Frequency Range (MHz) Splitting Loss (dB)
PS-R3-ON500C(H)
PS-R4-ON500C(H)
3 Ways
4 Ways
698-2700 3.1
5.0
6.3
≤0.1
Insertion Loss (dB)
≤1.20
Input Port VSWR
≤-150@2x43dBm
Intermodulation Products (dBc) Input Average Power, Maximum (W)
500
Peak Power, Maximum (W)
1000
Impedance (Ω)
50
Mechanical Specifications Parameters Dimensions, LxWxH (mm) / (in) Weight (including connectors) (kg) / (lb)
Specifications 2 Ways
3 Ways
4 Ways
214.8x60.6x25.0 / 8.5x2.4x1.0
269.4x60.6x25.0 / 10.6x2.4x1.0
270.6x60.6x42.8 / 10.7x2.4x1.7
0.35 / 0.77
0.41 / 0.90
0.47 / 1.05
Connector Type
N-Female
Operational Temperature (°C)
-40 to +60 ≤95
Operational Humidity (%) Shipping Dimensions LxWxH (mm) / (in) Shipping Weight (kg) / (lb)
240x80x35 / 9.4x3.1x1.4
280x80x35 / 11.0x3.1x1.4
280x80x50 / 11.0x3.1x2.0
0.37 / 0.82
0.43 / 0.95
0.51 / 1.12
Environmental Class
IP65
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-2 / 0414
Page 128 of 139
Filter Model
FP-G70-OD01
Frequency (MHz)
Isolation (dB)
Insertion loss (dB)
Connector Type
Power Handling (W)
890-960
≥
[email protected] ≥50@790-885MHz
≤
[email protected] ≤
[email protected] ≤1.2@892-898MHz ≤0.7@898-915MHz ≤0.3@935-960MHz
DIN-Female
200
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Dimension (mm)
310×124×58
Page 129 of 139
Band Pass Filter FP-G70-OD01 Pass Band: 890-960MHz
200W High power handling Low Return Loss – maximizes system performance Low Intermodulation Compact – minimizes space requirements
Electrical Specifications Frequency Range (MHz) Parameters / Specifications
890-960
[email protected]
[email protected] 1.2@892-898MHz 0.7@898-915MHz 0.3@935-960MHz 2.0 ≥
[email protected] ≥50@790-885MHz ≥20 (Normal) ≥18 (Extreme) 200
Insertion Loss(dB)
Passband Ripple (dB) Out of Band Rejection (dB) Return Loss Power Handling Continuous(W) Intermodulation products in Rx band (2x43 dBm Carrier) (dBc) Impedance (Ω)
-150 50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm) / (in) Weight (kg) / (lb) (Estimated)
Specifications 310×124×58 / 12.2x4.9x2.3 2.7 / 6.0
Color
Light grey
RF Connectors
7/16 DIN-Female Pole (clamps included for Ф35-125mm Pole) or Wall mounted
Mounting Operating Temperature Range (°C)
-20 to +65
Operational Humidity (%)
<95
Environment Class
IP66
Shipping Dimensions, LxWxH (mm) / (in)
500×220×220 / 19.7×8.7×8.7
Shipping Weight (kg) / (Ib)
4.2 / 9.3
Lightning Protection
Comply with IEC 61000-4-5; 8kA, 8/20s
GND
PORT2
PORT1
Outline Drawing
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 1-0-0 / 0116
Page 130 of 139
Multiple Operator Combiner Model
Frequency (MHz)
Connector Type
Dimension (mm)
POI-BD92ONY5
2xTetra Band, 1x800MHz, 4x900MHz, 4x1800MHz, 4x2100MHz, 1x2300MHz
N-Female
280x240x178
POI-CDG4IDN1
1x CDMA800, 1x GSM900, 1x DCS1800, 2x FDD-LTE1.8, 1x WCDMA, 1x FDD-LTE2.1, 1x TD-LTE(F), 1x TD-LTE(E)
Din-Female
482x430x577
@ Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-3 / 1214
Page 131 of 1
Multi Operator Combiner POI-BD92ONY5 1x CDMA800, 1x GSM900, 1x DCS1800, 2x FDD-LTE1.8, 1x WCDMA, 1x FDD-LTE2.1, 1x TD-LTE(F), 1x TD-LTE(E) High input power of 1000W Low insertion loss and passive intermodulation. High isolation. Including monitor, supporting local/remote monitor
Electrical Specifications Parameters
Specifications
Frequency (MHz) / Input Ports
CT CDMA800
820-835/865-880
CMCC GSM900
889-915/934-960
CMCC DCS1800
1710-1735/1805-1830
UNICOM FDD-LTE1.8
1735-1765/1830-1860
CT FDD-LTE1.8
1765-1785/1860-1880
CT FDD-LTE2.1
1920-1940/2110-2130
UNICOM WCDMA
1940-1980/2130-2170
CMCC TD-LTE(F)
1885-1915
CMCC TD-LTE(E)
2320-2370 5.5
Insertion Loss(dB) Pass-Band Ripple(dB)
Isolation (dB)
Return Loss(dB) IM3 ( 2x43 dBm Carrier, in RX band)(dBc) Input Power per Port-BTS Output Power per Port-ANT Impedance (Ω)
1.5 ≥25 @ UNICOM LTE1.8 / CT LTE1.8 ≥25 @ CMCC DCS / UNICOM LTE1.8 ≥25 @ CT LTE2.1 / WCDMA ≥50 @ CMCC DCS / CT LTE1.8 ≥50 @ CT LTE1.8 / TD-F ≥50 @ CT LTE2.1 / TD-F ≥80 @ Other Ports >18 -150@2x43dBm 200(Avg.) 1000(Peak) 500(Avg.) 2500(Peak) 50
Mechanical Specifications Parameters
Specifications
Dimensions, LxWxH (mm) / (in) Weight (kg) / (Ib)
13.4 / 29.5
Number of Input Ports - Duplex Number of Output Ports - Duplex RF Connectors
280x240x178 / 11.0x9.5x7.0
Input ports Output ports
Operating Temperature Range (°C) Operational Humidity (%) Environment Class Mounting Shipping Dimensions, HxWxD (mm) / (in) Shipping Weight (kg) / (Ib)
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 1015
9 2 N-Female 7/16 DIN-Female -44 to +55 5 to 98 IP65 Wall Mounting 450x400x250 / 17.7x15.7x9.8 15.0 / 33.1
Page 132 of 139
Monitor Specifications Parameters
Specifications
Support (Y/N)
Alarm (Y/N)
Input Power Detect Threshold(dB)
±2
Y
Y
Output Power Detect Threshold(dB)
±2
Y
Y
Load / Open
Y
Y
±1
Y
Y
Interrupted Power Alarm (Power Supply by Backup Battery)
Y
Y
LED
Y
/
Return Loss Detect Threshold Temperature Monitoring (oC) Power Alarm Power Supply Indicators Alarm Indicators
LED
Y
/
RS-232
Y
/
RS-485 and RJ-45
Y
/
Remote Communication Transmission
Optional
/
Local Monitoring Port RMON Port Wireless Modem
Block Diagram
CDMA800
820-835 865-880
GSM900
889-915 934-960
FDD-LTE1.8
TD-LTE(F)
WCDMA
1735-1765 1830-1860 1885-1915
1940-1980 2130-2170 2320-2370
30
ANT1
TD-LTE(E)
30 DCS1800
1710-1735 1805-1830
FDD-LTE1.8
1765-1785 1860-1880
FDD-LTE2.1
1920-1940 2110-2130
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 1015
ANT2
Page 133 of 139
Modular Multi Operator Combiner POI-CDG4IDN1 2xTetra Band, 1x800MHz, 4x900MHz, 4x1800MHz, 4x2100MHz, 1x2300MHz Permits combining of Tetra/800/900/1800/2100/2300 technologies Scalable design for easily upgrading to support 2600MHz (Optional via external unit to be purchased separately) Excellent passive inter-modulation performance
Electrical Specifications Parameters / Specifications Input Port
-Input Port Information (MHz)
Frequency Range
-TETRA 1
TX/RX
806-824/851-869
-TETRA 2
TX/RX
806-824/851-869
- 800
TX/RX
825-840/870-885
- 900-A
TX/RX
890-915/935-960
- 900-B
TX/RX
890-915/935-960
- 900-C
TX/RX
890-915/935-960
- 900-D
TX/RX
890-915/935-960
- 1800-A
TX/RX
1710-1785/1805-1880
- 1800-B
TX/RX
1710-1785/1805-1880
- 1800-C
TX/RX
1710-1785/1805-1880
- 1800-D
TX/RX
1710-1785/1805-1880
- 2100-A
TX/RX
1920-1980/2110-2170
- 2100-B
TX/RX
1920-1980/2110-2170
- 2100-C
TX/RX
1920-1980/2110-2170
- 2100-D
TX/RX
1920-1980/2110-2170
- 2300
TX/RX
Insertion Loss(dB) Isolation (dB) Return Loss(dB) Monitor Port Coupling value (dB) Maximum Input Power per Port (W) -TX Inter-modulation in Rx band (dBc) Impedance (Ω)
2300-2400 <8.0 ≥25 @same band ≥25@Tetra / 800 ≥80 @cross band >18 30±2 200(Avg.) 1000(Peak) ≤-155 @2x43dBm(Reverse) 50
Mechanical Specifications Parameters Dimensions, LxWxH (excluding connectors and mounting bracket) (mm)/ (in) Weight (including connectors and mounting bracket)( kg)/ (lb) Input-Duplex Connector Number and Output-Duplex Type Monitor ports Mounting Operating Temperature Range(°C) Operational Humidity (%) Environment Class Shipping Dimensions, LxWxH (mm)/ (in) Shipping Weight (kg)/ (lb)
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Specifications 482x430x577 / 19.0x16.9x22.7 58.0 / 127.9 16 x 7/16 Din-Female 4 x 7/16 Din-Female 4 x N-Female Floor Standing -10 to +60 ≤95 Indoor 83.0 / 183.0 830x680x760 / 32.7x26.8x29.9
Page 134 of 139
Block Diagram 800 900-C 1800-C 2100-C 2300
825-840/870-885
Module 1 Common Module
890-915/935-960 1710-1785/1805-1880 1920-1980/2110-2170 2300-2400
Module 1
TETRA-1 900 - B 1800-B 2100-B
806-824/851-869 890-915/935-960 1710-1785/1805-1880 1920-1980/2110-2170
ANT1
Module 1
TETRA-2 900- A 1800-A 2100-A
ANT2
806-824/851-869 890-915/935-960 ANT3
1710-1785/1805-1880
ANT4
1920-1980/2110-2170
Module 1
Load 890-915/935-960 900-D 1800-D 2100-D
1710-1785/1805-1880 1920-1980/2110-2170
TX/RX Unit
© Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers’ requirements. DS-Control: 3-0-0 / 0116
Page 135 of 139
This page intentionally left blank
Page 136 of 139
General Enquiries
[email protected] Tel: + 852 2636 6861 Fax: + 852 2637 0966
Sales Enquiries
[email protected]
Support & Technical Services
[email protected]
Marketing
[email protected]
Investor Relations
[email protected]
HR
[email protected] Website http://www.comba-telecom.com/ Website Feedback
[email protected]
China Headquarters Comba Telecom Systems China Ltd Add: No.10 Shenzhou Road, Guangzhou Science City, China Tel: +8620 2839 0000 Fax: +8620 2839 0136 Corporate & APAC Headquarters Comba Telecom Systems Holdings Ltd Add: 611 East Wing, No.8 Science Park West Avenue, Hong Kong Science Park, Hong Kong Tel:
+852 2636 6861
Fax: +852 2637 0966 / +852 2116 6055 Middle East Headquarters Comba Telecom Limited Add: Unit 112, Building 5, Gold and Diamond Park, Al Qouz, Dubai, UAE Tel: +971 0 4 346 7277 Fax: +971 0 4 346 7288 Europe Headquarters Comba Telecom Systems AB Add: Gustavslundsvagen 147, SE-167 51 Bromma, Stockholm, Sweden Tel: +46 8 253 870 Fax: +46 8 253 871 Caribbean and Latin America Headquarters Comba Telecom Ltda Add: Av. Doutor Chucri Zaidan nº29 – 29ºandar Conj. 2910/2911, Vila Cordeiro, Edificio Capital Corporate, 04583-110, Sao Paulo, Brazil Tel: +55 11 3509 4800 Fax: +55 11 3509 4833 North America Headquarters Comba Telecom Inc. Add: 235 Charcot Ave, San Jose, CA 95131, USA Tel: +1 408 526 0180 Fax: +1 408 526 0181 India Office (Operations Office) Comba Telecom India P Ltd Add: G-4 Sector 63, Noida – 201301 U.P, India Tel: +91 120-4599000 Fax: +91 120-4599001
For more local offices information, Please visit our website www.comba-telecom.com