Alphion Alphio n AONT-100C AONT-100C (SFU)
Catalog Number: AONT-100C-DOC-03 Part Number: 196-0000002 196-00000 02 Rev 02
Alphion AONT-100C (SFU) User Guide Catalog Number: AONT-100C-DOC-03 Part Number: 196-0000002 Rev 02
PART NUMBER: 196-0000002 REVISION 02 PUBLISHED: MARCH 2008
ALPHION CORPORATION 196 PRINCETON HIGHTSTOWN ROAD BUILDING 1A PRINCETON JUNCTION, NJ 08550 WWW.ALPHION.COM
COPYRIGHT Copyright © 2008 Alphion Corporation, Inc. All Rights Reserved. Printed in U.S.A. Alphion AONT-100C (SFU) User Guide Catalog Number: AONT-100C-DOC-03
COPYRIGHT Copyright © 2008 Alphion Corporation, Inc. All Rights Reserved. Printed in U.S.A. Alphion AONT-100C (SFU) User Guide Catalog Number: AONT-100C-DOC-03 Part Number: 196-0000002 Revision 02 March 2008
TRADEMARKS All of the Alphion names, brand names, and product names referred to in this Document, in particular, the name “Alphion” and its logo, are either registered trademarks or trademarks of the Alphion Corporation. All other registered trademarks or trademarks are the property of their respective owners.
LIMITED WARRANTY Alphion warrants that this Document has been delivered free of all rightful claims of any third person by way of infringement or the like of any copyright, trade secret, or trademark. THIS DOCUMENT AND THE PRODUCTS DESCRIBED THEREIN (COLLECTIVELY, THE “DELIVERABLES”) ARE PROVIDED “AS IS” AND ALPHION MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DISCLAIMS ANY AND ALL OTHER WARRANTIES WITH RESPECT TO THE DELIVERABLES, OR ANY MODIFICATIONS THERETO, IN WHOLE OR IN PART, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ALPHION OR ANY ALPHION EMPLOYEE BE LIABLE FOR THE ACCURACY OR COMPLETENESS OF THE DELIVERABLES.
2
EXCLUSION OF CONSEQUENTIAL DAMAGES; LIMITATION OF LIABILITY ALPHION SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO BUYER FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR INDIRECT DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES, EVEN IF ALPHION HAS BEEN APPRISED OF THE LIKELIHOOD OF SUCH DAMAGES. IN NO EVENT SHALL ALPHION'S LIABILITY TO BUYER FOR DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES
EXCLUSION OF CONSEQUENTIAL DAMAGES; LIMITATION OF LIABILITY ALPHION SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO BUYER FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR INDIRECT DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES, EVEN IF ALPHION HAS BEEN APPRISED OF THE LIKELIHOOD OF SUCH DAMAGES. IN NO EVENT SHALL ALPHION'S LIABILITY TO BUYER FOR DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES EXCEED THE AGGREGATE PRICE OF THE DELIVERABLES.
3
4
In this guide Before you begin, please read all safety information on page 10. This guide covers information on the following: ■
Connecting the AONT-100C on page 6
■
Verifying Connections on page 9
In this guide Before you begin, please read all safety information on page 10. This guide covers information on the following: ■
Connecting the AONT-100C on page 6
■
Verifying Connections on page 9
■
Troubleshooting on page 10
■
Safety on page 12
Figure 1
Alphion AONT-100C
5
Connecting the AONT-100C To set up the connections for the AONT-100C, follow the instructions below:
Connect the Network
Connecting the AONT-100C To set up the connections for the AONT-100C, follow the instructions below:
Connect the Network The network connection should already be established. If it is not, please contact your service provider.
Connect Power Connect the power adapter to the power connector on the side of the unit. Plug the power adapter into an electrical outlet. Verify that the POWER LED on the front of the unit is solid green. Verify that the FIBER LED on the front of the unit is solid green (not flashing).
Connect Data Service Connect Ethernet cables to the Ethernet ports on the side of the unit.
6
Connecting the AONT-100C
Configure PPPoE on a Client in Windows XP 1 2 3
From your desktop, click Start. Choose Connect To>> Show All Connections. In the left panel, click Create a New Connection. The New Connection Wizard opens. Click Next.
Configure PPPoE on a Client in Windows XP From your desktop, click Start. Choose Connect To>> Show All Connections. In the left panel, click Create a New Connection. The New 2 Connection Wizard opens. Click Next. 3 Select Option 1, “Connect to the Internet.” Click Next. 4 Select Option 2, “Set Up My Connection Manually.” Click Next. 5 The Wizard asks “How do you want to connect to the Internet?” 6 Selection Option 2, “Connect Using a Broadband connection that requires a user name and password.” Click Next. Enter a name for the connection. Click Next. 7 Enter the Username and Password as configured in the server 8 (/etc/ppp/pap-secrets.) Click Finish. A new connection now exists in the Network 9 Connections box. 10 To establish a PPPoE connection, right-click the Newly Created Network Connection and select Connect. 11 Click Connect. The client dials the PPPoE Connection. For instructions on how to configure PPPoE in a Microsoft Vista operating environment, go to www.microsoft.com and search on the term “PPPoE.” 1
Connecting the AONT-100C
Connect Phone Service Connect phone wires to the phone ports on the side of the unit. Link LED (green)
E T
7
Connect Phone Service Connect phone wires to the phone ports on the side of the unit. Link LED (green) Activity LED (amber)
E T H 1 E T H 2
Ethernet Ports
E T H 3 E T H 4
T E L 1
Phone Ports
T E L 2 R e s e t P W R
Figure 2
Reset Power 12VDC
Connection Ports on Side of Unit
8
Connecting the AONT-100C
Verifying Connections To verify that all the connections are active, check the LEDs on the front of the unit.
Verifying Connections To verify that all the connections are active, check the LEDs on the front of the unit.
Figure 3
LEDs on Front of Unit
They should appear as follows: POWER
Green
FIBER
Green
DATA
Green (if data service is enabled)
UPDATE
Off (unless software upgrade is in progress)
TEST
Off
PHONE
Off (or green if phone is off the hook)
9
Verifying Connections
Troubleshooting Below are the LED states with an explanation of each. If a problem is indicated, see Getting Support. POWER
S lid
O
i
f
AC
Troubleshooting Below are the LED states with an explanation of each. If a problem is indicated, see Getting Support. POWER
FIBER
Solid green
Operating from AC power
Flashing green
Operating from battery power
Red
Operating from battery power and battery is low
Solid green
Network is fully operational
Flashing green
Network is in ranging and synchronizing process—should change to solid green within approximately 1 minute
Red
Unrecoverable failure of hardware or software self test
Off
Unit is not operational
10
Troubleshooting
DATA
Solid green
At least one Ethernet link is active
Flashing green
At least one Ethernet link is active and receiving/ transferring data
Off
Ethernet service is not enabled
DATA
UPDATE
PHONE
Troubleshooting
Solid green
At least one Ethernet link is active
Flashing green
At least one Ethernet link is active and receiving/ transferring data
Off
Ethernet service is not enabled or Ethernet link is not established
Flashing green
Software download is in progress. Do not turn power off while flashing
Off
No software update in progress
Solid green
At least one phone is in use/off the hook
Flashing green
At least one phone has been in use/off the hook for more than one hour
Off
Telephone service not established or all phones connected to unit are on the hook
11
You're Reading a Preview Unlock full access with a free trial.
Download With Free Trial
Laser Safety Caution: Do not use controls, adjustments, or procedures other than specified. This could result in hazardous laser radiation exposure. Never look directly into an unterminated cable or connection. Invisible laser radiation may be emitted from the ends of unterminated fiber cables or connectors.
Laser Safety Caution: Do not use controls, adjustments, or procedures other than specified. This could result in hazardous laser radiation exposure. Never look directly into an unterminated cable or connection. Invisible laser radiation may be emitted from the ends of unterminated fiber cables or connectors. The AONT-100 uses a Class I laser device.
Safety
13
14
Safety
Catalog Number: AONT-100C-DOC-03 Part Number: 196-0000002 Rev 02 April 2008