Loop Checking and Field Instrument Testing ProcedureDescription complète
Description complète
manual step by step for testing and repair procedure of electro motorFull description
Windings Checking of 3 Phase MotorFull description
describes loop checking of instrumentation. An instrument technician must have known loop checking.
Full description
loop checking instrumentationDescription complète
loop checking instrumentationDescripción completa
loop checking instrumentationDescrição completa
Full description
CS6612, IT6612 COMPILER LAB MANUAL,
loop checking instrumentation
Genie-Code Checking
ProcedureFull description
oxygen sensor checking audi b5
DC motor shaft
Rotor magnet
stator
Stator wiring
Mold resin
2-12 V DC DC
Fig. Wiring of DC motor
Motor PWB
Vm ; motor voltage input Vcc ; Control power voltage input GND ; gnd Vs ; Speed control voltage input
Over heat protection starts at 125 15 over.
Fig. DC Fan motor construction
FG ; Revolution pulse output For MACO USE ONLY
1. Indoor DC Fan motor (type A) Fig. Wiring from PWB ①Power voltage input (Vm /red) ② NC ③GND (Gnd /black) ④Control signal (Vcc /white) ⑤Speed control signal (Vsp /yellow) ⑥Revolut Revolution ion output output (Vfg (Vfg /blue /blue))
Indoor DC Motor Part no. SSA512T072A SSA512T081 SSA512T092
4 5 1
Meas easuri uring poin pointt Resi Resisstanc tance e when hen norma ormall 25 kΩ or higher - 3 (Vcc - Gnd) 200 kΩ or higher - 3 (Vsp - Gnd) 1 MΩ or higher 25 - 3 (Vm - Gnd) For MACO USE ONLY
2 . Outdoor DC Fan motor (type D) ZG model
Fig. Wiring from PWB ① Revolution output (Vfg /blue) ② Speed control signal (Vsp /yellow) ③ Control signal (Vcc /white) ④ GND (Gnd /black) ⑤ NC ⑥ Power voltage input (Vm /red)
Outdoor DC Motor Part no. SSA512T075 SSA512T091A SSA512T094
3 2 6
Measu easuri ring ng poin pointt Resi Resisstan tance when when norma ormall 25 kΩ or higher - 4 (Vcc - Gnd) 200 kΩ or higher - 4 (Vsp - Gnd) 1 MΩ or higher 25 - 4 (Vm - Gnd) For MACO USE ONLY
DMCT Checker procedure 1. 2. 3.
Turn Turn moto motorr by hand hand,, if har hard d reje reject ct (mot (motor or faul faulty ty)) , if if easy easy go to to step step 2 Chec Ch eck k resi resista stanc nce e each each wire wire by digit digital al mete meterr ,co ,comp mpare are with with stand standar ard d valu value e Runn Runnin ing g che check ck by DMC DMCT, conf confir irm mVD DC C ou output tput from from DMC DMCT.
2. Check resistance each wire by digital meter ,compare with standard value
3. Check by DC motor checker
1
For MACO USE ONLY
Analysis DC motor improvement BEFORE
AFTER 1
Only check by digital meter, measured resistance each wire, compare with standard - Difficult Difficult to to judgment judgment -Up to many type of Digital meter. -Up to experience each Service man
st
1 check resistance of each wire nd if pass go to check step 2 nd
2 check by dc motor checker. Running test condition. -Easy and fast to judgment. -It can guarantee 100% to separate good dc motor before change.