solving transportation problems using modi method[Linear Programming]
Description : Skrill Method
Full description
Descripción: DUDUK FLUTE ARMENIAN METHOD
FORMAT UTILE:(841 X 594)
8
7
6
5
4
3
SIZE
DWG.NO.
SH.
219D1732
A1
1
REV.
1/2
A
REVISIONS REV
DATE
NAMES/NOMS
15/09/2008
AFR - JLC. RENIER L. BELPERRON S.
DESCRIPTION
A
FIRST ISSUE
NOTES: 1 - VOIR MLI 0414, NOMENCLATURE DES APPAREILS POUR LE REGLAGE DES APPAREILS. 1 - SEE MLI 0414, DEVICE SUMMARY FOR DEVICE SETTING.
D
D
2 - VOIR MLI 0313 ET 0314 POUR LES CARACTERISTIQUES DES CONNEXIONS. 2 - SEE MLI 0313 AND 0314 FOR CONNECTIONS CHARACTERISTICS. 3 - ARTICULATION. 3 - SPHERICAL BEARING. 4 - SI LA TEMPERATURE DES TUYAUTERIES DE LIAISON PEUT DESCENDRE EN DESSOUS DE 15°C DU FAIT DE LA TEMPERATURE AMBIANTE, IL EST OBLIGATOIRE DE LES TRACER ET CALORIFUGER POUR MAINTENIR AU MOINS A 15°C. 4 - IF CONNECTING PIPING TEMPERATURE MAY DECREASE LOWER THAN 15°C (59°F) DUE TO AMBIENT TEMPERATURE, IT IS MANDATORY THAT HEAT TRACING AND INSULATING BE USED TO MAINTAIN THEM AT LEAST AT 15°C (59°F).
A
REV
2
1
SH
REV STATUS OF SHEETS
GE-123E4888
SPECIFICATION P&ID
1
C
A
2
EXTRA RULES FOR 04XX SCHEMATICS CREATION
3
SYSTEM AND COMPONENT CLEANLINESS REQUIREMENTS
IT.
379A9908
C
GE-362A2412
NOMENCLATURE
IDENT
LIST OF COMPLEMENTARY DOCUMENTS
ITEM : 0469
FIRST MADE FOR : MS 9001E
TO
H
48
LEAVE THIS SPACE BLANK
45
B
None
FO R
AFR IN
A1
AFR IN
22/07/2008
RENIER LUCIE
BELPERRON SANDRINE
RENIER LUCIE
BELPERRON SANDRINE
G E
SCHEMA CDE. AUBES VARIABLES
22/07/2008
VALIDE
15/09/2008
O ffi ci al
EX
EC
U
TI
O N
U
N
IT
H
B
NOMS / NAMES
CHECKED APPROVED
A
RENIER L. BELPERRON S.
0469 Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel. Il ne peut être communiqué, copié ou reproduit sans son autorisation écrite préalable.
8 FORMAT A1:841 X 594 (ISO 5457-1980)
SCHEMA CDE. AUBES VARIABLES. A DIAG. SCH. PIPING IGV.
7
CAGE CODE
219D1732
SIZE
DWG.NO.
A1
This document, exclusive property of GE Energy Products France SNC is strictly confidential. It must not be communicated copied or reproduced without our previous written consent.
SIM TO:
6
5
4
3
1/2
206D6828
SCALE
2
REV. :
A
219D1732 DT-1C
SHEET : 1/2
1
01
X F
DISTR CHENUT BRIGITTE GIRNEATA GEORGE TO
DRAWN DIAG. SCH. PIPING IGV. AFR - JLC.
FORMAT UTILE:(841 X 594)
8
7
6
5
4
3
SIZE
DWG.NO.
A1
SH.
219D1732
1
REV.
2/2
A
D
D
VOIR NOTE 4 SEE NOTE 4
ANNEAU DES AUBES ENTREE INLET GUIDE VANE RING
PDIH
100
DI 200 0,76 mm - 0.030 "
OH-4 DE/FROM MLI.0434 OH-4
FI 100
MODULE AUXILIAIRES ACCY MODULE
20TV-1
FH6-1
C C
P
R
1
2
FERME CLOSE
(96TV-1) ZE
ZE
90TV-1
(96TV-2)
OUVERT OPEN
LEAVE THIS SPACE BLANK
48
VH3-1B
TO
H
VH3-1A
45
B
N
W
D
O N
U
DI 100 1,78 mm - 0.070 "
IT
H
B
DI 101 1,78 mm - 0.070 "
TI
D
15/09/2008
None
COMPARTIMENT TURBINE GAS TURBINE COMPARTMENT
AFR IN
FO R
OD
AU DESSUS DU NIVEAU ABOVE FLUID LEVEL
EX
0548
A1
AFR IN
22/07/2008
RENIER LUCIE
BELPERRON SANDRINE
RENIER LUCIE
BELPERRON SANDRINE
G E
SCHEMA CDE. AUBES VARIABLES
22/07/2008
VALIDE
EC
HM3-1
O ffi ci al
U
W
NOMS / NAMES
CHECKED APPROVED
A
RENIER L. BELPERRON S.
0469 Ce document, propriété exclusive de GE Energy Products France SNC est strictement confidentiel. Il ne peut être communiqué, copié ou reproduit sans son autorisation écrite préalable.
8 FORMAT A1:841 X 594 (ISO 5457-1980)
SCHEMA CDE. AUBES VARIABLES A DIAG. SCH. PIPING IGV.
7
CAGE CODE
219D1732
SIZE
DWG.NO.
A1
This document, exclusive property of GE Energy Products France SNC is strictly confidential. It must not be communicated copied or reproduced without our previous written consent.