Client: Nabors Arabia Report No.: 14-219R Contract No.: 14-219 P.O Box No. 2862, Al Khobar 31952 Date of Inspection: 24/Mar/2014 Kingdom of Saudi Arabia
Vessel/Site: Nabors 655 Location: Offshore KSA Colour Code:
Stabbing Board Inspection A. Historical Data
Item: Check records and certification as applicable
Status Sat
Unsat
Comments / Recommendations Recommendations NA
1. Load test record & certificate
Date:
Cert#:
2. Wire rope certification
Date:
Cert#:
3. NDT inspection of critical load bearing points
Date:
Cert#:
4. Data plate installed B. Inertia Reel & Safety Equipment
Item: Check condition of the following and record
Status Sat
Unsat
Comments / Recommendations Recommendations NA
1. Correctly mounted to the mast (bracket, padeye, beam clamp) 2. Carry out function test and inspection of the following: Free movement / retraction Jerk / stop test Line inspected Carabiner / Line clip (free movement, screw lock) 3. Safety belt Condition ('D' Rings webbing etc.) Safety line Safety line anchor point rating Safety line anchor point location in compliance with latest IADC Safety Safety Alert. 4. SCBA (where applicable) C. Construction
Item: Check condition of the following and record
Status Sat
Unsat
Comments / Recommendations Recommendations NA
1. Access ladder (rungs, Anti-fall, step-off etc.) 2. Condition braces / members (no bends, twists, corrosion etc.) 3. Bolts tight - Nut s locked/pinned 4. Mast mounts inspected
Revision No: 1
Date of Issue:
Reviewed by:
Checked by:
Inspected by: D. O'Brien
M. Qureshi
Authorised by: J. King
This certification or report is granted granted or issued subject to the condition that it is understood and and agreed upon that nothing nothing herein shall be deemed to relieve relieve any designer, manufacturer, seller, supplier, repairer, or operator operator of any warranty, warranty, express or implied and OES Ltd. Liability shall be limited to the acts and omissions of it’s employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any def ect in materials, machinery, equipment, or other items other than than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Seve rity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
Client: Nabors Arabia Report No.: 14-219R Contract No.: 14-219 P.O Box No. 2862, Al Khobar 31952 Date of Inspection: 24/Mar/2014 Kingdom of Saudi Arabia
Vessel/Site: Nabors 655 Location: Offshore KSA Colour Code:
Stabbing Board Inspection 5. Safety hobble installed between frame & derrick (anchored above uppermost point of frame) 6. Floor & side grating inspected 7. Anti-slip surfaces installed 8. Extension inspected Hinge pins Safety hobble Gate chain 9. Two independent safety systems installed 10. End stops installed on guide track D. Travel Operation
Item: Check condition of the following and record
Status Sat
Unsat
Comments / Recommendations NA
1. Condition of rollers - (free travel, lubricated) Hydraulic rams Hoses and connections (whip checks) Ram operation and seals Pilot check valves operation at ram Hydraulic pressure Control operational - clearly marked 3. Pneumatic / Electric / Hydraulic Hoist Hoses & connections Spring loaded safety latch allowing ratchet up/lock down Controls free & clear of obstruction Controls clearly marked Controls return to neutral Upper & lower limit switches installed and operational Suitable for manriding operations (fitted with auxiliary brake)
Revision No: 1
Date of Issue:
Reviewed by:
Checked by:
Inspected by: D. O'Brien
M. Qureshi
Authorised by: J. King
This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd. Liability shall be limited to the acts and omissions of it’s employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any def ect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Seve rity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
Client: Nabors Arabia Report No.: 14-219R Contract No.: 14-219 P.O Box No. 2862, Al Khobar 31952 Date of Inspection: 24/Mar/2014 Kingdom of Saudi Arabia
Vessel/Site: Nabors 655 Location: Offshore KSA Colour Code:
Stabbing Board Inspection E. Visibility
Item: Check condition of the following and record
Status Sat
Comments / Recommendations
Unsat
NA
1. Clear view to drillers console 2. Drillers board clearance indicator installed and functional F. Photographic record
G. Corrective Action Pictures
1
2
Revision No: 1
Date of Issue:
Reviewed by:
Checked by:
3
Inspected by: D. O'Brien
M. Qureshi
Authorised by: J. King
This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd. Liability shall be limited to the acts and omissions of it’s employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any def ect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Seve rity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.