Home
Add Document
Sign In
Register
03-TA-08 Rev-B
Home
03-TA-08 Rev-B
ta 08Full description...
Author:
neothejackal
9 downloads
227 Views
524KB Size
Report
DOWNLOAD .PDF
Recommend Documents
Videowall Design Guide RevB
wegfwg
PLC DVP Fundamentals RevB
PLC DVP Fundamentals RevB delta
ESR00550- Cold Field Bending-revB
Procedure cold bendingFull description
A1083290 - MAN - CG+MP16II RevB
mpi20
Matlab Para Dinamica de Estructuras RevB
matlab
Matlab Para Dinamica de Estructuras RevB
matlabDescription complète
Monorail Beam Design Bechtel RevB (2)
Monorail Beam Design Bechtel RevB (2)
Problemas de Evaluacion de Proyectos RevB (2)
analisis de riegos
r99-0068-Rtf a-series Operating Manual Revb
Range to faultFull description
Ceragon FibeAir IP-10C Product Description ETSI RevB.01
ceragonFull description
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA
PROCESS LOAD SHEET FOR ADDITIVE TANK 03-TA-08 DOC. NO.
:
DS-03-018-129
CLIENT
:
PT. PERTAMINA (Persero)
PROJECT TITLE
:
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA PROJECT
LOCATION
:
TANJUNG PRIOK - JAKARTA
CONTRACT NO.
:
LATER
JOB. NO
:
2F1002
B
11-Mar-11
REV
DATE
Issued for Information DESCRIPTION
SM/NK
AM/IRJ
IRJ
Prep'd
Check'd
Appr'd
By
Date
Client Approval
PROCESS - DATASHEET
ADDITIVE TANK REV B
ENGINEERING PROCUREMENT CONSTRUCTION
DESCRIPTION
BY CHK'D SM/NK AM/IRJ
Issued for Information
APP'D DATE IRJ 11-Mar-11
UUPPJ PROJECT 1 2 3 4 5
TAG NUMBER SERVICE NUMBER P&ID DOCUMENT NO
6
: 03-TA-08 : ADDITIVE TANK : 1 (ONE) UNIT : : DS-03-018-129 OPERATING
N5
PROCESS DESIGN
N3
N4
N 11
MW 2
7 8 9
Pressure Temperature
ATM
Full of Liquid
o
o
46 C
56 C
N6
10 11 12 13
Materials Corrosion allow
Carbon Steel
Fluid Viscosity Specific Gravity Vapor Pressure
Additive A21 o 3900 cSt @ 40 C o 0.976 @ 15.6 C
N7
14 15 16 17 18 19
MW1
20 22 23 24 25 26 27 28 29
N9
N1
21
Yes (Full) N/A 3 800 m 3 896 m 9.68 m x
Insulation Lining Working Capacity Nominal Capacity Dimension (ID X H) Addition : - Flame Arrestor - Breather Valve
N10 N8
12.17
N2
m
No Yes
30 31 32
Vessel Heating
Suction Heater c/w Hot Insulation LIQUID LEVEL
NOZZLE DATA
33
Level (mm)
34 35 36 37
LLLL LLL HLL
500 550 11661
38 39 40 41 42 43 44 45 46 47 48 49
Notes : 3 1. Inlet nozzle size based on 400 m /h (max. loading arm capacity)
Ref
Nb
inch
Rating-Facing
Service
MW1 MW2 N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11
1 1 1 1 1 1 1 1 1 1 1 1 1
24 24 10 (*1) 2 2 2 4 B 2 2 6 2 2 4
150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF 150# - RF
Man Hole Man Hole Liquid Inlet Manual Drain Level Transmitter Level Switch Vent Overflow Temperature Transmitter Liquid Outlet Steam Coil Inlet Steam Coil Outlet Return Line
ATTACHMENT
1.
Basis of Calculation
2.
Calculation Sheet
.
ozz e
.
en ng
a cu a on a cu a on
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA
BASIS OF CALCULATION - ADDITIVE TANK CLIENT LOCATION
1
Page
PT. PERTAMINA (Persero)
Prp.
Chk.
Apr.
Date
B
SM/NK
AM/IRJ
IRJ
11-Mar-11
TANJUNG PRIOK - JAKARTA
PROJECT
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA PROJECT
PROJECT NO.
2F1002
DOC. NO.
DS-03-018-129
1
BASIS OF CALCULATION - ADDITIVE TANK
2 3 4 5
Objective To size the Additive Tank
6 7
Basis
8
1 . D en si ty o f A dd it iv e
=
9
2. Additive Filling rate capacity
975
3
kg/m
=
400
m3 /hr
(Max. Marine Loading Arm transfer rate capacity)
10 11
Assumption
12
1. Additive supply
=
30
13
2. Estimated holding time is
=
26.7
m3 /hr hr
14 15
Calculations
16
1. Size of the Additive Tank
17
Required working volume
=
800.0
m3
18
Margin 0%
=
800.0
m3
19 3
20
The Working Volume of the Additive Tank Provided
=
800
m
21
Tank Volume / Capacity
=
896
m3
22 23 24 25 26 27 28 29 30 31 32
4
of
Rev.
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA
ADDITIVE TANK - CALCULATION CLIENT
PT. PERTAMINA (Persero)
LOCATION
TANJUNG PRIOK - JAKARTA
PROJECT
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA PROJECT
PROJECT NO.
2F1002
DOC. NO.
DS-03-018-129
1
2
Page
4
of
Rev.
Prp.
Chk.
Apr.
Date
B
SM/NK
AM/IRJ
IRJ
11-Mar-11
Calculations
2 3
h3
4
H.L.L
5
h3
=
vapor space
6
h2 =
7 8
he igh t of work ing vo lum e
h2 12170 mm
9
L.L.L
10 11
h1c
12
h1
13
h1
h1b
h1a
14
=
bottom to L.L.L space
Outlet nozzle
15
9680 mm
16 17
1.
(defined as per API 650)
h1 (Bottom to L.L.L space) calculation 6 in. NPS
18
Outlet nozzle diameter
19
h1a
=
200 mm
20
h1b
=
76.2 mm
21
h1c
=
152.4 mm
=
428.6 mm
h1
22
(From Table 3.6 API 650) ( = 0.5 * Nozzle OD) ( = 1 * Nozzle OD) Take
h1
500 mm
23 24
2.
h2 (Height of working volume) calculation Est. working volume
800.0 m 3
27
H/D Ratio
1.175
1.123
28
Diameter
9680 mm
9680 mm
29
Height
25
Take
26
11371 mm
3.
h3 (vapor space)
=
790 mm
32 33
Final Dimension
34
Diameter
35
Height
36
H/D check
37
Total Capacity
38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
=
10871 mm
Calc. working vol.
800.04 m3 OK !
30 31
h2
9680 mm 12170 mm 1.26 895.6 m 3
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA
Page 3
ADDITIVE TANK - NOZZLE AND LIQUID LEVEL CALCULATION
CLIENT LOCATION PROJECT PROJECT NO. DOC. NO.
PT. PERTAMINA (Persero)
REV
TANJUNG PRIOK - JAKARTA UPGRADI NG UNI T PRO DUKSI PELUM AS JAKARTA PROJECT
DATE BY
SM/NK
2F1002 DS-03-018-129
CHECK
AM/IRJ
APPR.
IRJ
Liquid Inlet
of
4
B 11-Mar-11
Liquid Outlet
Mass Flow = Density = Act Vol. Flow =
390,000 kg/hr
Mass Flow =
975.0 kg/m3 400.00 m3 /hr
29,250 kg/hr
Actual Vol. Flow =
975.0 kg/m3 30.00 m3 /hr
Design Pump Flow =
33.00 m3 /hr
Density =
Design For One Tank: Holding Time = Liq uid Volum e = LLLL = (LLLL~HLL)/D =
26.7 hours 800. 0 m3 0.500 m
Tank Diameter =
9.68 m
LLLL~ HLL =
10. 871 m
Vapour space Height =
6.78 %
=
0.79 m
Tank Height =
12.17 m
Tank Volume = H/D =
896 m3 1.26
LLL Calculation
working vol. : 800 m3 HLL
0.79
1.123 10.87
dL (in)
12.17
LLL 0.05 m
LLLL h1c
0.50
h
h1
=
6
h1a (mm) =
200
h1b (mm) =
76.2
h1c (mm) =
152.4
h1
428.6
(mm) =
Take LLLL(mm)
500
dL h1a
LLLL~LLL Calc
9.68
#REF!
in
Liquid Inlet Nozzle diameter : dF =
10 in
ID =
0.0511 m2 2.1756 m/s
vF = 2
4615.0787 kg/m.s2 Liquid Outlet Nozzle diameter : ρ FvF
=
dF =
6.063 0.0186 m2 0.4921 m/s
AF = vF = 2
ρ FvF
OK!
6 in
ID =
=
236.1374 kg/m.s2
5 37.37
Take (mm)
10.039
AF =
Hold time (min) LLLL~LLL (mm)
OK!
50
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA
ADDITIVE TANK 03-TA-08 - VENT SIZE CALCULATION CLIENT
PT. PERTAMINA (Persero)
LOCATION
TANJUNG PRIOK - JAKARTA
Page
PROJECT
UPGRADING UNIT PRODUKSI PELUMAS JAKARTA PROJECT
PROJECT NO.
2F1002
DOC. NO.
DS-03-018-129
4
4
of
Rev.
Prep.
Chk.
Apr.
Date
B
SM/NK
AM/IRJ
IRJ
11-Mar-11
Vent Nozzle Size Calculation (Based on API 2000)
1 2
3
Tank Capacity (Nominal)
=
896
m
5
Liquid flash point
=
200
°C
6
Liquid normal boiling point Wetted surface area
=
100
°C
=
345.80
m
3 4
7
2
8 9
1.
Inbreathing
10 11
Q1 (Maximum Movement Out of Tank)
=
5.6
SCFH of Air
12
(per section 4.3.2.1.1)
=
0.94
Nm3/hr of Air
13
Outflow
=
14
Air inlet
=
per per
CFH of Liquid Outflow m3/hr of Liquid Outflow
(Table A.1 of API-2000 Ed 2009)
33.0 m3 /hr 31.0 Nm3 /hr
15 16
Q2 (Thermal Inbreathing)
=
17
(per section 4.3.2.1.2)
=
Total Vacuum Relief Required (Q)
=
5342 Nm3 /hr 151.3 Nm3 /hr
(Interpolation Table A.3 of API-2000 ed. 2009)
18 19 20
=
21
=
Q1
+ 3
31.0 Nm /hr 182.3 Nm3 /hr
Q2 151.3 Nm3 /hr
+
22 23 24
2.
Outbreathing - Pressure Relief
25 26
Q1 (Maximum Movement IntoTank)
=
6
SCFH of Air
27
(per section 4.3.2.1.1)
=
1.01
Nm3/hr of Air
28
Inflow
=
29
Air outlet
=
per per
CFH of Liquid Outflow m3/hr of Liquid Outflow
(Table A.1 of API-2000 Ed 2009)
400.0 m3 /hr 404.0 Nm3 /hr
30 31
Q2 (Thermal Outbreathing)
=
32
(per section 4.3.2.1.2)
=
Total Vacuum Relief Required (Q)
=
3203 ft3 /hr 90.8 Nm3 /hr
(Interpolation Table A.3 of API-2000 ed. 2009)
33 34 35
=
36
=
Q1
+
404.0 Nm3 /hr 494.8 Nm3 /hr
+
Q2 90.8 Nm3 /hr
37 38 39
3.
Take the largest from (1) and (2) :
Q
=
494.8
=
282.0
3
Nm /hr
41
Maximum velocity at nozzle
=
Am3 /hr 10.0 m/s
42
Pipe size
=
Q x 4
40
43
0.8 x
π
x 3600
44 45 46 47 48 49 50 51
Take pipe size
=
100
mm
=
3.9329
in
=
4
in
(minimum 2 in)
×
Report "03-TA-08 Rev-B"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close