ZWS-PAF SERIES
Single Output 150W, 240W
ZWS240PAF/A
ZWS150PAF/L
ZWS240PAF ZWS150PAF
2
■ Features
■ Model naming method
ZWS 150PAF-24/ 150PAF-24/□ □□
Complies the standard of the harmonics current limit ● Power supply for motor drive in mechatronics products: Applicable for 24V pulse load ● Ultracompact and high power: Peak power of twice the value of average power ● Worldwide input voltage range: 8585-265VAC 265VAC ● Complies the harmonics current limit standard: Builtin active lter ● Small leak current: Convenient for use in combination with power supply for logic (use of multiple units of power supply) ● A wide variety of optional items/Harmonics current limiter
■ Applications
Option 1 Blank: PCB type L: L-shape metal plate type A: With cover Option 2 Blank: Molex connector J: JST connector T: Terminal block(vertical) block(vertical) S: Terminal block(horizontal) block(horizontal)
Nominal output voltage Active filter Peak current Nominal output voltage Series name
■ Conformity to RoHS Directive This means that, in conformity with EU Directive 2002/95/ 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specic bromine-based ame retardants, PBB and PBDE, have not been used, except for exempted applications.
■ Product Line up Output Voltage
150W
240W
Current(Peak)
Model
Curren( t Peak)
Model
24V
6.3A(12A)
ZWS150PAF-24/J
10A(20A)
ZWS240PAF-24/J
36V
4.2A(8A)
ZWS150PAF-36/J
6.7A(13.3A)
ZWS240PAF-36/J
48V
3.1A(6A)
ZWS150PAF-48/J
5A(10A)
ZWS240PAF-48/J
ZWS ZWS -PAF
・All specifications are subject to change without notice.
A-447
ZWS150PAF
ZWS1 ZW S150 50P PAF (Convection (Convecti on Cooli ng) Specific Specif ications ations ITEMS/UNITS
Voltage Range Frequency
MODEL
(*3) (*3)
Z WS WS15 0P 0PA FF-24/J
Z WS WS150 PA PAF- 36 36/J
V Hz
AC 85 - 265 or DC120 - 370 47- 63 0.99 / 0.95
Power Factor (100/200VAC)(typ) (*2)
Input
Efficiency (typ) (*2) Current (10 0 /20 0VAC)(typ) (*2) Inrush C urrent (100/20 0VAC)(typ)(*4) Leakage Current Nominal Voltage
(*10)
Ma ximum Current Ma ximum Peak Current Ma ximum Power Ma ximum Peak Power
(*1) (*1)
Ma ximum Line Regulation (*5)(*6) Output Ma ximum Load Regulation (*5)(*7)
% A A mA VDC A A W W mV mV mV mV
82 2.0 / 1.0 14 / 28 at Ta=25 Ta=25℃, cold start 24
0.5 Ma x, 0.1 (typ) at 10 0VAC / 0.16 (typ) at 230VAC 36
48
6. 3
4. 2
3.1
8
6 148.8
12 151.2
288 96 192
14 4 288
192 384
240 36 0
Less than 0.02%/℃ 360 5 40 20
48 0 720
Temperature Coeff icient Maximum Ripple & Noise (0
Hold -up Time (typ)
(*2) ms
Voltage Adjustable Range Over Current Protection
VDC (*8) VDC
21.6 - 28.8 > 12.3
32.4 - 41.4 > 8. 2
4 3.2 - 52.8 > 6.1
Over Voltage Protection
(* 9) VD V DC
3 0 . 0 - 3 5 .0
4 3.2 - 50.4 Possible Possible
5 5. 2 - 6 4.8
Function Remote ON/OFF Control
Parallel Operation Series Operation
℃
- 10 to + 60 Convection: -10 to +50 (100%); (100%); 60 (70%)
℃
- 30 to +85
Operating Humidity
%RH
30 - 9 0 (No dewdrop)
Storage Humidity
%RH
Operating Temperature
(*11)) (*11
Storage Temperature Environment
10 - 95 (No dewdrop) At no operating,10 - 55Hz (sweep for 1min) 19.6m/s² constant, X, Y, Y, Z 1hour each
Vibration
Isolation
Standards
Mechanical
Z WS WS15 0P 0PA FF- 48 48/J
Shock (In package)
Less than 196.1m/s²
Cooling
Convection cooling Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA) Output - FG : 500VAC (100mA) for 1min. 1min.
Withstand Voltage Isolation Resistance Safe Sa fety ty St Stan anda dard rds s PFHC EMI Immunity Weight (typ) Size ( W x H x D)
More than 100MΩ at Ta=25℃ and 70%RH, Output - FG : 500VDC Appr Ap prov oved ed by UL UL60 6095 9500-1 1, CS CSA A C2 C22. 2.2 2 No No.6 .609 0950 50--1, EN EN60 6095 9500-1 1 Bu Buil iltt to me meet et DE DENA NAN N Built to meet EN61000-3-2
(*1 (* 12) (*13)
Built to meet VCCI -B, FCC - Class B, EN55 011/EN55 022- B Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-1 EN61000-4-2,-3,-4,-5,-6,-8,-11 1 g mm
(*1) Operating period at peak peak output current is less than 10 sec. (Duty < 0.35) (Average output power and current is less than maximum output power and current.) For peak load derating method, please refer to instruction manual for details. (*2) At 100/200VAC and maximum output power, Ta = 25℃. (*3) For cases where conformance to various safety safety specs (UL, CSA, EN) are required, to be described as 100-240VAC, 50/60Hz on name plate. (*4) Not applicable for the in-rush current to noise filter for less than than 0.2ms. (*5) Please refer to Fig A for measurement of line & load load regulation and output ripple voltage. (Measure with JEITA RC-9131 probe.)
500 8 0 x 40 x 20 8 (Refer to outline drawing)
(*7) No load - full load (maximum power), constant input voltage. voltage. (*8) Constant current limit with automatic recovery. recovery. Avoid to operate at overload or dead short for more than 30 seconds. (*9) OVP circuit will shutdown output, manual reset. reset. (Line recycle) (*10) Measured by each measuring method of UL, CSA, EN and DENAN (at 60Hz). (*11)) At standard mounting method, Fig B. (*11 -Load(%) is percent of maximum output load, do not exceed derating in both maximum output current and power. -For other mountings, refer to derating curve. -When forced air cooling, refer to derating curve. (*12) As for DENAN, built to meet at 100VAC. (*13) 85-265VAC, no load - full load, constant load.
(*6) 85-265VAC, constant constant load.
●Recommended EMC Filter
ZWS ZWS -PAF
A-448
RSEL-2006W Please refer to "TDK-Lambda EMC Filters" catalog.
・All specifications are subject to change without notice.
ZWS150PAF
ZWS1 ZW S150 50P PAF (Forced Ai r Cooli Cooling) ng) Spe Speci cific fic ations ITEMS/UNITS
Input
MODEL
Environment
Standards
ZWS150PAF-36
Voltage Range
(* 3)
V
Frequency
(* 3)
HZ
47- 63
Cur rent (10 0/ 20 0VAC)(t yp)
(*4)
A
2. 8 / 1.4
Nominal Voltage
Output
ZWS150PAF-24
ZWS150PAF- 48
AC85 - 265 or DC120 - 370
VDC
24
36
48
M axim um Cur rent
(*1)
A
8.4
5.6
4. 3
M axim um Peak Cur rent
(* 2)
A
12
8
6
M axim um Power
(*1)
W
M axim um Peak Power
(* 2)
W
Hold - Up Time (t yp)
(*4)
ms ms
16
℃
-10 to +70 -10 to +50 (100%); 60 (91%); (91%); 70 (70%)
Operating Temperature
(*5)(*6)
201.6
20 6. 4 28 8
Cooling
(*1)
Forced air cooling
EM I
(*7)
Built to meet VCCI - A , FCC- Class A , EN55 011/ EN5 50 22- A
(*1) Forced air cooling with air velocity more than 1.5m/s (measured at component side of PCB, air must flow through component side)
●Recommended EMC Filter
(*2) Operating period at peak output current current is less than 10sec. (Duty < 0.35) (Average output power and current is less than Maximum output power and current.) For peak load derating method, please refer to instruction manual for details. (*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, required, to be described as 100-240VAC, 50/60Hz on name plate. (*4) At 100/200VAC and maximum output output power, Ta = 25℃. (*5) At standard mounting method A, and and other mountings B, C, D, E. - Load(%) is percent of maximum output load, do not exceed derating in both maximum output current and power.
RSEL-2006W Please refer to "TDK-Lambda EMC Filters" catalog.
(*6) Output derating for cold start up at at Ta = - 10℃ for input voltage : 85VAC 80%, 90VAC 86.7%, 100-265VAC 100%. No output derating for input voltage is required after start up for one second. (*7) 85-265VAC, Full load.
ZWS ZWS -PAF
・All specifications are subject to change without notice.
A-449
ZWS150PAF
Outline Drawing 【ZWS150PAF(/J : JST connector)】
1980.5
5
5 1 . 0
3
0
1 2
3
1
8 0 7
1 6 . 7 0
9 . 8 4
4
5 6
4
5
371
5
194.3 2081
CONNECTORS USED PART DESCRIPTION
J.S.T.
1
PIN HEADER (OUTPUT SIDE CN51) B6P-VH
J.S.T.
1
SOCKET HOUSING (CN1) VHR-5N
J.S.T.
1
SOCKET HOUSING (CN51) VHR-6N TERMINAL PINS (CN1, CN51) SVH-21T-P1.1
J.S.T.
1
J.S.T.
9
(unit : mm)
PART NAME MANUFACTURER QTY
PIN HEADER (INPUT SIDE CN1) B3P-5-VH
MATCHING HOUSINGS & PIN. * NOT INCLUDED WITH THE PRODUCT.
HAND CRIMPING TOOL : YC-160R
NOTES: A. THE 4- φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. B. MODEL NAME, INPUT VOLTAGE RANGE,NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. C. COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D. TO KEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND CUSTOMER'S CHASSIS. E. FG IS FOR SAFETY GROUND CONNECTION. F. REMOTE ON/OFF CONTROL CONNECTOR (CN2,CN52) : B2B-XH-A M (J.S.T.) *CN2 IS NORMAL LY SHORTED BY JM-2W-96(J.S.T.) MATCHING HOUSING : XHP-2(J.S.T) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.)OR SXH001T-P0.6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
MANUFACTURER : J.S.T.
【ZWS150PAF(/JL : With L-shape metal plate, JST connector)】 2200.5
5
5 . 4
5 . 7
0 2 5 1 . 7 2 6 4
5 . 4
205.3
5
5 5 . . 0 0
1
3
2
0 6 4
9 . 3 5
6 6 . 7 5
4 5 6
5 5 1 2
0 9
5 . 4 5 4
4
CONNECTORS USED PART DESCRIPTION
1
3
1
0
PART NAME MANUFACTURER QTY
PIN HEADER (INPUT SIDE CN1) B3P-5-VH
J.S.T.
1
PIN HEADER (OUTPUT SIDE CN51) B6P-VH
J.S.T.
1
*OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
MATCHING HOUSINGS & PIN.
2200.5 2301
5
NOTES A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.) C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURR ENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: FG IS FOR SAFETY GROUND CONNECTION. E: REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH- AM (J.S.T.) *CN2 IS NORMAL LY SHORTED BY JM-2W-96(J.S.T.) MATCHING HOUSING : X HP-2 (J.S.T.) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
* NOT INCLUDED WITH T HE PRODUCT.
(unit : mm)
SOCKET HOUSING (CN1) VHR-5N
J.S.T.
1
SOCKET HOUSING (CN51) VHR-6N TERMINAL PINS (CN1, CN51) SVH-21T-P1.1
J.S.T. J.S.T.
1 9
HAND CRIMPING TOOL : YC-160R
MANUFACTURER : J.S.T.
【ZWS150PAF(/JA : With cover, JST connector)】
5
2200.5 5 . 4
5 . 7
0 2
5 . 1 6 7 4 2 1 5
5 . 4
205.3
NOTES A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE IN TO POWER SUPPLY BY MORE THAN 6mm. B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.) C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: FG IS FOR SAFETY GROUND CONNECTION.
5
5 5 . . 0 0
3
1
2
0
3
1
4
0 6 4
ZWS -PAF
1
6 6 . 7 5
9 . 3 5
4
6
5 . 4
0 9
5 4
5 5 1 2
5
5
A-450
PART NAME MANUFACTURER QTY
PIN HEADER (INPUT SIDE CN1) B3P-5-VH
J.S.T.
1
PIN HEADER (OUTPUT SIDE CN51) B6P-VH
J.S.T.
1
*OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
MATCHING HOUSINGS & PIN. * NOT INCLUDED WITH T HE PRODUCT.
2200.5 2301
CONNECTORS USED PART DESCRIPTION
(unit : mm)
SOCKET HOUSING (CN1) VHR-5N
J.S.T.
SOCKET HOUSING (CN51) VHR-6N TERMINAL PINS (CN1, CN51) SVH-21T-P1.1
J.S.T.
1
J.S.T.
9
HAND CRIMPING TOOL : YC-160R
MANUFACTURER : J .S.T.
・All specifications are subject to change without notice.
1
ZWS150PAF
Outline Drawing NOTES: A. THE 4- φ3.5 HOLES ARE FOR CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. B. MODEL NAME, IN PUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. C. COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D. TO KEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND CUSTOMER'S CHASSIS. E. FG IS FOR SAFETY GROUND CONNECTION. F. REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH -AM (J.S.T.) *CN2 IS NORMALLY SHORTED BY JM-2W-96(J. S.T.) MATCHING HOUSING : XH P-2 (J.S.T.) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.) OR SXH-0 01T-P0.6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
【ZWS150PAF(/T : Vertical terminal) 】
1980.5
6 . 8
5 1 . 0
0 8 0 7
0 1
6 . 8 0 1
1 6
3-M4
1
8 4
2-M4
4
5
24MAX
5
194.3 2081
371
(unit : mm)
【ZWS150PAF(/TL : Vertical terminal, with L-shape metal plate)】 2SEE NOTE A
2200.5
5
5 . 7 .
.
5 . 4
.
.
.
0 . 2
1 5 . 7 6 2 4 . .
5 . 4 .
. -
2SEE NOTE B -
2SEE NOTE B
-
. . 205.3
SEE NOTE E 4NOTE A I L
I TERMINAL I COVER
2NOTE B
.
0 0
0 0
L
VR51
SEE NOTE E
6 . 8
I
N
INPUT
COMPONENT I SIDE
0 1
12
RR .
CN2 2 1
SEE NOTE B
CN51
OUTPUT
R R
.
6 4
6 . 8 0 1
3M4
V
6
1
.
V
6 6
3 5
.
0 9
5 . 4
2M4 5 4
4
5 5 1 2
. . 0.5 220 2301
5
MAX 33
I L TERMINAL COVER
CN52
.
. FG
.
5 . 5 .. .
VOLTAGE ADJUSTMENT
SEE NOTE D CN1
NAME PLATE
(unit : mm)
NOTES A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.) C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: FG IS FOR SAFETY GROUND CONNECTION. E: REMOTE ON/OFF CONT ROL CONNECTOR (CN2, CN52) : B2 B-XH-AM (J.S.T.) *CN2 IS NORMAL LY SHORTED BY JM-2W-96 (J.S.T.) MATCHING HOUSING : XH P-2 (J.S.T.) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
【ZWS150PAF(/TA : Vertical terminal, with cover)】
2200.5
5
5 . 4
5 . 7
0 2 5 1 . 6 7 4 2 1 5
5 . 4
205.3
6 . 8
5 5 . . 0 0
0 0 6 4
6 . 8
0 1
3-M4
6 6
3 5
6 4
0 1
1
5 . 4
0 9
2-M4 5 4
5 5 1 2
5 33MAX
2200.5 2301
(unit : mm)
NOTES A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.) C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: FG IS FOR SAFETY GROUND CONNECTION.
・All specifications are subject to change without notice.
ZWS -PAF
A-451
ZWS150PAF
Outline Drawing 【ZWS150PAF(/S : Horizontal terminal) 】
1980.5
3-M4
2-M4
6 . 8 5 . 1 0 0
1 0 0 8 7
6 . 8 0 1
1 6
1
8 4
4
5
8.1
5
194.3 2081
20
14.6
MAX
371
20
MAX
NOTES: A: THE 4- φ3.5 HOLES ARE FOR CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. B: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN ACCORDA NCE WITH TH E SPECIFICATION S. C: COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D: TO KEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND CUSTOMER'S CHASSIS. E: FG IS FOR SAFETY GROUND CONNECTION. F: REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH-AM (J.S.T.) *CN2 IS NORMALLY SHORTED BY JM-2W96 (J.S.T.) MATCHING HOUSING : XHP-2 (J.S.T.) MATCHING TERMINAL : BXH -001T-P0.6 (J.S.T.) OR SX H-001T-P0 .6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
(unit : mm)
【ZWS150PAF(/SL : Horizontal terminal, with L-shape metal plate)】 2200.5
0 2 1
6 4
205.3
3-M4
6 . 8 5 . 0 0 1
0 6
6 . 1 8 0 1 0 9
6 6
6
3 5
2-M4
NOTES: A: M4 EMBOSS ED TAPPED & COUNT ERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: MODEL NAME, N OMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT. PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN H ERE IN ACCOR DANCE WIT H THE SPECIFICATIONS. C: FG IS FOR SAFETY GROUND CONNECTION. D: REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH-AM (J.S.T.) *CN2 IS NORMALLY SHORTED BY JM-2W96 (J.S.T.) MATCHING HOUSING : XHP-2 (J.S.T.) MATCHING TERMINAL : BXH -001T-P0.6 (J.S.T.) OR SX H-001T-P0 .6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
4
5 1
(17.1)
2200.5
5
MAX 9
23.6
MAX 9
2301
(unit : mm)
【ZWS150PAF(/SA : Horizontal terminal, with cover)】 2200.5
5 0 2 1 6 4 1 5
3-M4
205.3
6 . 8 0 1
NOTES: A: M4 EMBOSS ED TAPPED & COUNT ERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: MODEL NAME, N OMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN H ERE IN ACCOR DANCE WIT H THE SPECIFICATIONS. C: FG IS FOR SAFETY GROUND CONNECTION.
5 . 0
0 6
6 6
6
3 5
6 . 1 8 0 1 0 9
2-M4
4
5 1
(17.1) 23.6
5
2200.5
9 MAX
2301
9 MAX
(unit : mm)
ZWS -PAF
A-452
・All specifications are subject to change without notice.
ZWS150PAF
Output Derating 【ZWS150PAF】 Recommended standard mounting method is (A). (B), (C), (D) and (E) are also possible. Mounting (F), (G), (H) and (I) are prohibited. Please do not use (F), where the PCB will be on the top side and heat will be trapped inside the unit. In the following derating curve, average load (%) is percent of maximum output load (both maximum output current and maximum output power in specication.) Do not exceed the load derating. ●PCB type
MOUNT ING(A)
MOUNTING MOUNTING
(B)
STANDARD MOUNTING
MOUNTING
MOUNTING
(D)
(E)
(C)
(F)DON'T USE
●With chassis & cover type
MOUNT ING(A) STANDARD MOUNTING
MOUNTING MOUNTING
(B)
MOUNTING
MOUNTING
(D)
(E)
(C)
*COOLING : CONVECTION COOLING OUTPUT DERATING CURVE(PCB type and with chassis type)
(F) DON'T USE
(G) DON'T USE(H)DON'T USE ( I ) DON'T USE
*COOLING : FORCED AIR COOLING OUTPUT DERATING CURVE(PCB type and with chassis type)
(A), (B) 100 150W
100 200W (A), (B), (C), (D), (E)
80
80 75 150W
(C), (D), (E) 60
60 40
40 20
20
0 -10
0
10
20
30
40
50
60
0 -10
0
10
20
40
50
60
70
*COOLING : CONVECTION COOLING OUTPUT DERATING CURVE(With chassis and cover type) 100 150W
30
(A)
*COOLING : FORCED AIR COOLING OUTPUT DERATING CURVE(With chassis and cover type) 100 200W (A), (B), (C), (D), (E)
(C), (E) 80 75 150W
80
60 40
60 40
(B), (D)
20
20
0 -10
0
10
20
30
40
50
60
0 -10
0
10
20
30
40
50
60
70
Recommended Minimum Air Velocity : 0.7m/s (Measured at component side of PCB, Air must flow through component side.) As a reference for forced air cooling, let air flow so that the transformer T1 core temperature is lower than 85℃.
ZWS -PAF
・All specifications are subject to change without notice.
A-453
ZWS240PAF
ZWS240PAF (Convection Cooli ng) Specifications MODEL ITEMS/UNITS
Voltage Range Frequency
(*3) (*3)
ZWS240PAF-24/J
V Hz
Efficiency (typ) Current (100/200VAC)(typ)
(*2) (*2)
Inrush Current (100/200VAC)(typ) (*4)
Leakage Current Nominal Voltage
(*10)
Maximum Current Maximum Peak Current Maximum Power Maximum Peak Power
(*1) (*1)
Maximum Line Regulation (*5)(*6) Output Maximum Load Regulation (*5)(*7)
0.99 / 0.95
% A A mA VDC A A W W mV mV
82 3.2 / 1.6 14 / 28 at, Ta=25℃, cold start 24
0.5 Max, 0.1 (typ) at 100VAC / 0.22 (typ) at 230VAC 36
10
6.7
5
20 240 480
13.3 241.2 478.8
10 240 480
96 192
144 288
192 384
240 360
Less than 0.02%/℃ 360 540 20
480 720
Temperature Coeff icient Maximum Ripple & Noise (0
(*2)
Voltage Adjustable Range Over Current Protection
VDC (*8) A
21.6 - 28.8 > 20.5
32.4 - 41.4 > 13.7
43.2 - 52.8 > 10.3
(*9) VDC
30.0 - 35.0
43.2 - 50.4 Possible Possible
55.2 - 64.8
Operating Temperature
(*11)
Storage Temperature Operating Humidity Storage Humidity
ms
℃
- 10 to + 60 Convection: -10 to +45 (100%); 60 (60%)
℃ %RH %RH
- 30 to +85 30 - 90 (No dewdrop) 10 - 95 (No dewdrop) At no operating,10 - 55Hz (sweep for 1min) 19.6m/s² constant, X, Y, Z 1hour each
Vibration Shock (In package)
Less than 196.1m/s²
Cooling Isolation
Convection cooling Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA) Output - FG : 500VAC (100mA) for 1min.
Withstand Voltage
More than 100MΩ at Ta=25℃ and 70%RH, Output - FG : 500VDC
Isolation Resistance
Standards
48
Hold-up Time (typ)
Over Voltage Protection Function Remote ON/OFF Control Parallel Operation Series Operation
Environment
ZWS240PAF- 48/J
AC85 - 265 or DC120 - 370 47-63
Power Factor (100/200VAC)(typ) (*2)
Input
Z WS240 PAF- 36/J
Safety Standards PFHC
EMI Immunity Weight (typ) Mechanical Size (W x H x D)
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1, Built to meet DENAN Built to meet EN61000-3-2 (*12) g mm
(*1) Operating period at peak output current is less than 10 sec. (Duty < 0.35) (Average output power and current is less than maximum output power and current.) For peak load derating method, please refer to instruction manual for details. (*2) At 100/200VAC and maximum output power, Ta=25℃. (*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100-240VAC, 50/60Hz on name plate. (*4) Not applicable for the in-rush current to noise filter for less than 0.2ms. (*5) Please refer to Fig A for measurement of line & load regulation and output ripple voltage. (Measure with JEITA RC-9131 probe.)
Built to meet VCCI-B, FCC-Class B, EN55011/EN55022-B Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11 750 95 x 45 x 222 (Refer to outline drawing)
(*6) 85-265VAC, constant load. (*7) No load - full load (maximum power), constant input voltage. (*8) Constant current limit with automatic recovery. Avoid to operate at overload or dead short for more than 30 seconds. (*9) OVP circuit will shutdown output, manual reset. (line recycle) (*10) Measured by each measuring method of UL, CSA, EN and DENAN (at 60Hz). (*11) At standard mounting method, Fig B. - Load(%) is percent of maximum output load (Item 2 and 5), do not exceed derating in both maximum output current and power. - For other mountings, refer to derating curve. - When forced air cooling, refer to derating curve. (*12) 85 - 265VAC, No load - full load, constant load.
● Recommended EMC Filter
ZWS -PAF
A-454
RSEL-2006W Please refer to "TDK-Lambda EMC Filters" catalog.
・All specifications are subject to change without notice.
ZWS 240PAF
ZWS240PAF (Forced Ai r Cooling) Specific ations ITEMS
Input
MODEL
Environment
Standards
ZWS240PAF-36
Voltage Range
(*3)
V
Frequency
(*3)
HZ
47-63
Current (100/200VAC)(typ)
(*4)
A
4.0 / 2.0
Nominal Voltage
Output
ZWS240PAF-24
ZWS240PAF-48
AC85 - 265 or DC120 - 370
VDC
24
36
48
Maximum Current
(*1)
A
12.5
8.4
6.3
Maximum Peak Current
(*2)
A
20
13.3
10
Maximum Power
(*1)
W
300
Maximum Peak Power
(*2)
W
480
Hold-Up Time (typ)
(*4)
ms
16
(*5)(*6)
℃
- 10 to + 70 -10 to +60 (100%); 70 (70%)
Operating Temperature
302.4 478.8
480
Cooling
(*1)
Forced air cooling
EMI
(*7)
Built to meet VCCI-A, FCC-Class A, EN55011/EN55022-A
(*1) Forced air cooling with air velocity more than 1.5m/s (measured at component side of PCB, air must flow through component side).
●Recommended EMC Filter
(*2) Operating period at peak output current is less than 10 sec. (Duty ≦ 0.35) (Average output power and current is less than maximum output power and current.) For peak load derating method, please refer to instruction manual for details. (*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*4) At 100/200VAC and maximum output power, Ta = 25℃. (*5) At standard mounting method A,and other mountings B, C, D, E. - Load(%) is percent of maximum output load, do not exceed derating in both maximum output current and power.
RSEL-2006W Please refer to "TDK-Lambda EMC Filters" catalog.
(*6) Output derating for cold start up at Ta = - 10℃ for input voltage : 85VAC 80%, 90VAC 86.7%, 100-265VAC 100%. No output derating for input voltage is required after start up for one second. (*7) 85 - 265 VAC, full load.
ZWS -PAF
・All specifications are subject to change without notice.
A-455
ZWS240PAF
Outline Drawing 【ZWS240PAF(/J : JST connector)】
CONNECTORS USED PART DESCRIPTION PART NAME MANUFACTURER QTY
2120.5
PIN HEADER (INPUT SIDE CN1)
5 1 . 0
5
9 5 8
4 . 2 8
. 7 8
5 . 2 6
5
J.S.T.
1
SOCKET HOUSING (CN1) VHR-5N SOCKET HOUSING (CN51) VHR-8N TERMINAL PINS (CN1, CN51) SVH-21T-P1.1
PIN HEADER (OUTPUT SIDE CN51) B8P-VH
* NOT INCLUDED WITH THE PRODUCT.
5
1320.5
1
MATCHING HOUSINGS & PIN.
5
421
J.S.T.
* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
B3P-5-VH
(unit : mm)
HAND CRIMPING TOOL : YC-160R
J.S.T.
1
J.S.T. J.S.T.
1 11
MANUFACTURER : J.S.T.
2221
NOTES: A. THE 5- φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. B. MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. C. COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. D. TO KEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND CUSTOMER'S CHASSIS.
E. FG IS FOR SAFETY GROUND CONNECTION. F. REMOTE ON/OFF CONTROL CONN ECTOR (CN2,CN52) : B2B-XH-AM (J.S.T.) *CN2 IS NORMAL LY SHORTED BY JM-2W-96(J.S.T.) MATCHING HOUSING : XH P-2 (J.S.T.) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.) HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
【ZWS240PAF(/JL : With L-shape metal plate, JST connector)】 2350.5
5 0 1
0 3 5 1 . 0
1 5
PIN HEADER (INPUT SIDE CN1)
5 . 4
5 3
5 0
) 4 . 7 8 (
) 5 . 7 6 (
5 5 1 6 4
(218.5)
5 1 5 . . 0 0
CONNECTORS USED PART DESCRIPTION PART NAME MANUFACTURER QTY J.S.T.
1
J.S.T.
1
* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
MATCHING HOUSINGS & PIN. * NOT INCLUDED WITH T HE PRODUCT.
SOCKET HOUSING (CN1) VHR-5N SOCKET HOUSING (CN51) VHR-8N TERMINA L PINS (CN1, CN51) SVH-21T-P1.1 HAND CRIMPING TOOL : YC-160R
5 . 4
) 7 . 3 6 (
B3P-5-VH
PIN HEADER (OUTPUT SIDE CN51) B8P-VH
J.S.T.
1
J.S.T. J.S.T.
1 11
MANUFACTURER : J .S.T.
3 5
7 7 2 1
2350.5 2451
5
(unit : mm)
NOTES ACCORDANCE WITH THE SPECIFICATIONS. A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASD: FG IS FOR SAFETY GROUND CONNECTION. SIS MOUNTING. SCREW M UST NOT PROTRUDE INTO POWER SUPPLY BY MORE E: REMOTE ON/OFF CONT ROL CONNECTOR (CN2, CN52) : B2 B-XH-AM (J.S.T.) THAN 6mm. *CN2 IS NORMAL LY SHORTED BY JM-2W-96(J.S.T.) B: φ 4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MATCHING HOUSING : XH P-2 (J.S.T.) MOUNTING. (USE M4 MOUNTING SCREW.) MATCHING TERMINAL : BXH- 001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.) C: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T. OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN 1
1
7
【ZWS240PAF(/JA : With cover, JST connector)】 2350.5
5 0 1
6 5
1
0 3 5 1 . 0
CONNECTORS USED PART DESCRIPTION PART NAME MANUFACTURER QTY
1
PIN HEADER (INPUT SIDE CN1)
7
5 . 4
5 3
(218.5)
3
5 1 5 . .
1
0 0 5 0
1
2 3 4 5
6 7
) 4 . 7 8 (
8
) 5 .
5 5 1 6 4
) 7 . 3 6 (
7 6 (
J.S.T.
1
PIN HEADER (OUTPUT SIDE CN51) B8P-VH
J.S.T.
1
* OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
MATCHING HOUSINGS & PIN.
51
5
B3P-5-VH
5 . 4
* NOT INCLUDED WITH T HE PRODUCT.
SOCKET HOUSING (CN1) VHR-5N SOCKET HOUSING (CN51) VHR-8N TERMINA L PINS (CN1, CN51) SVH-21T-P1.1 HAND CRIMPING TOOL : YC-160R
J.S.T.
1
J.S.T. J.S.T.
1 11
MANUFACTURER : J .S.T.
3 5
7 7 2 1
5
ZWS -PAF
235 2451
(unit : mm)
NOTES A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING, SCREW M UST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm. B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (2) ARE FOR CUSTOMER CHASSIS
A-456
MOUNTING. (USE M4 MOUNTING SCREW.) C: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS. D: FG IS FOR SAFETY GROUND CONNECTION.
・All specifications are subject to change without notice.
ZWS240PAF
Output Derating 【ZWS240PAF】 Recommended standard mounting method is (A). (B), (C), (D) and (E) are also possible. Mounting (F), (G), (H) and (I) are prohibited. Please do not use (F), where the PCB will be on the top side and heat will be trapped inside the unit. In the following derating curve, average load (%) is percent of maximum output load (both maximum output current and maximum output power in specication.) Do not exceed the load derating.
●PCB type
MOUNTING(A) MOUNTING (STANDARD MOUNTING) (B)
MOUNTING (C)
●With chassis & cover type
MOUNTING (D)
MOUNTING (E)
(F)DON'T U SE
MOUNTING(A) MOUNTING (B) (STANDARD MOUNTING)
MOUNTING (C)
MOUNTING (D)
MOUNTING (E)
*COOLING: CONVECTION COOLING OUTPUT DERATING CURVE(PCB type and with chassis) 120
(F)DON'T U SE
(G)DON'T USE (H) DON'T USE
(I) DON'T USE
*COOLING: FORCED AIR COOLING OUTPUT DERATING CURVE(PCB type and with chassis) 120
(A), (B), (C), (D), (E)
(A)
100 240W
(B)
80
100 300W 80
60 40
60 40
(C), (D) (E)
20
20
0 -10
0
10
20
30
40
50
60
70
0 -10
0
10
20
40
50
60
70
*COOLING: CONVECTION COOLING OUTPUT DERATING CURVE(With cover) 120
*COOLING: FORCED AIR COOLING OUTPUT DERATING CURVE(With cover) 120
(A), (B), (C), (D), (E)
(A) 100 240W
100 300W
80
60 40
30
80
60
(B), (C)
40
(D), (E) 20
0 -10
20
0
10
20
30
40
50
60
70
0 -10
0
10
20
30
40
50
60
70
Recommended Minimum Air Velocity:0.7m/s (Measured at component side of PCB, Air must flow through component side.) As a reference for forced air cooling, let air flow so that the transformer T1 core temperature is lower than 85℃ .
ZWS -PAF
・All specifications are subject to change without notice.
A-459
ZWS-PAF SERIES
Bloc k Diagram 【ZWS150PAF, ZWS240PAF】
●Circuit mode and swtching frequency Switching circuit:Single-ended forward topology(130kHz) PFHC circuit:Active filter(90kHz) ●Fuse rating…ZWS150PAF:5A, ZWS240PAF:6.3A
Circuit for Measuring Performances (ZWS150PAF, ZWS240PAF) :150mm Wire material: AWG#18 C1: Electrolytic capacitor 100µF C2: Film capacitor 0.1µF
ZWS -PAF
A-460
・All specifications are subject to change without notice.
ZWS150PAF
SERIES
ZWS150PAF Series Ins tr uc ti on Manu al
BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electric shock, damage to the unit or a re hazard.
● Never operate the unit under over current or shorted conditions for 30 seconds or more and out of input voltage range in specification which could result in damage or insulation failure or smoking or burning. ● Conrm connections to input/output terminals are correct as indicated in the instruction manual. ● This power supply is PC board type unit. Please hold the board edge while mounting, and do not touch the component side. Please lift the power supply with a spacer when mounting the power supply on any surface. ● Do not drop or apply shock to power supply unit.
WARNING and CAUTION ● Do not modify. ● Do not touch the internal components, they may have high voltage or high temperature. You may get electric shock or burned. ● When the unit is operating, keep your hands and face away from it, you may get injured by an accident. ● This power supply is primarily designed and manufactured to be used and enclosed in other equipment. Stick the WARNING label for users on the system equipment and describe the notice in the instruction manual.
Note:CE MARKING
Alpha II DLP
FPS
Genesys HK-A
CE Marking, when applied to a product covered by this handbook, indicates compliance with the low voltage directive (73/23/EEC) as modied by the CE Marking Directive (93/68/ EEC) which complies with EN60950.
HWS JWS-P
1. Terminal Explanation
JWT
MTW
ZWS150PAF
● Input & Output connector (MOLEX) (also for option model /L, /A)
RKE
Connector
Housing
Terminal Pin
5414-30B
5239-06 or 2139-06 or 3069-06
5167PBTL
5273-06A
5239-06 or 2139-06 or 3069-06
Input (CN1)
Output (CN51)
① L:
RKY
RTW 5167PBTL
AC Input terminal (pin 6 of CN1) Live line (fuse in line) *Output current of each connector pin must be less than 5A. ② N: AC input terminal (pin 4 of CN1) *Hand crimping tooling: JHTR2445A (MOLEX) Neutral line ● Connector for Remote ON/OFF ③ FG: Input terminal FG (pin 1 of CN1) Safety earth (Frame Ground) control: CN2, CN52 (J.S.T) Connect to safety ground of apparatus or equipment. Connector Housing Terminal Pin ④ FG: Frame Ground (Connected to pin 1 of CN1) Must be connected to electrically safe ground of apparatus or BXH-001T-P0.6 equipment by electrically conductive spacers. The mounting B2B-XH-AM XHP-2 or SXH-001T-P0.6 surface of the spacer should be within MAX 8mm. ⑤ CN2: ON/OFF control terminal (primary circuit) See NOTE A. *CN2 is normally shorted by JM-2W-96 (J.S.T) ⑥ +: + Output terminal *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T) ⑦ −: − Output terminal ⑧ V.ADJ: Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer isturned clockwise. ⑨ CN52: ON/OFF control terminal (secondary circuit) (For power supply output on and o controlwith an external signal.) See NOTE A. NOTE A: For cover & chassis type (model: ZWS150PAF/A), remote ON/OFF control cannot be used.
SWT UNA VS
VS-P ZUP
ZWDPAF ZWQ ZWS
2 ZWS150PAF/J
ZWS -PAF
・All specifications are subject to change without notice.
A-461
ZWS150PAF ① L: ② N: ③ FG:
④ FG:
Alpha II ⑤ CN2:
DLP
⑥ +: ⑦ −: ⑧ V.ADJ:
FPS
⑨ CN52:
Genesys
SERIES ● Input & output connector (J.S.T) (also for option model /JL, /JA)
AC Input terminal (pin 1 of CN1) Live line (fuse in line) N: AC input terminal (pin 3 of CN1) Neutral line Input terminal FG (pin 5 of CN1) Safety earth (Frame Ground) Connect to safety ground of apparatus or equipment. Frame Ground (Connected to pin 5 of CN1) Must be connected to electrically safe ground of apparatus or equipment by electrically conductive spacers. The mounting surface of the spacer should bewithin MAX 8mm. ON/OFF control terminal (primary circuit) See NOTE A. + Output terminal − Output terminal Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) See NOTE A.
Housing
Terminal Pin
Input (CN1)
B3P-5-VH
VHR-5N
SVH-21T-P1.1
Output (CN51)
B6P-VH
VHR-6N
SVH-21T-P1.1
*Output current of each connector pin must be less than 5A. *Hand crimping tool: YC-160R (J.S.T)
● Connector for Remote ON/OFF control: CN2, CN52 (J.S.T) Connector
Housing
Terminal Pin
B2B-XH-AM
XHP-2
BXH-001T-P0.6 or SXH-001T-P0.6
*CN2 is normally shorted by JM-2W-96 (J.S.T). *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
NOTE A: For cover & chassis type (model: ZWS150PAF/JA), remote ON/OFF control cannot be used.
HK-A
Connector
HWS
3 ZWS150PAF/T JWS-P JWT
MTW
RKE ① L:
RKY
② N:
RTW
③ FG:
SWT
④ FG:
UNA ⑤ CN2:
VS
⑥ +: ⑦ −: ⑧ V.ADJ:
VS-P ⑨ CN52:
ZUP
Connector Input (CN1)
T6957-A
Output (CN51)
T7094-A
● Connector for Remote ON/OFF control: CN2, CN52 (J.S.T) Connector
Housing
Terminal Pin
B2B-XH-AM
XHP-2
BXH-001T-P0.6 or SXH-001T-P0.6
*CN2 is normally shorted by JM-2W-96 (J.S.T). *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
NOTE A: For cover & chassis type (model: ZWS150PAF/TA), remote ON/OFF control cannot be used.
ZWDPAF ZWQ
● Input & output connector (EMUDEN) (also for option model /TL, /TA)
AC Input terminal L (M4 screw) Live line (fuse in line) AC input terminal N (M4 screw) Neutral line Input terminal FG (M4 screw) Safety earth (Frame Ground) Connect to safety ground of apparatus or equipment. Frame Ground Must be connected to electrically safe ground of apparatus or equipment by electrically conductive spacers. The mounting surface of the spacer should be within MAX 8mm. ON/OFF control terminal (primary circuit) See NOTE A. + Output terminal (M4 screw) − Output terminal (M4 screw) Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) See NOTE A.
4 ZWS150PAF/S
ZWS
ZWS -PAF
A-462
・All specifications are subject to change without notice.
ZWS150PAF ① L: ② N: ③ FG:
④ FG:
⑤ CN2: ⑥ +: ⑦ −: ⑧ V.ADJ: ⑨ CN52:
SERIES ● Input & Output connector (EMUDEN) (also for option model /SL, /SA)
AC Input terminal L (M4 screw) Live line (fuse in line) AC input terminal N (M4 screw) Neutral line Input terminal FG (M4 screw) Safety earth (Frame Ground) Connect to safety ground of apparatus or equipment. Frame Ground Must be connected to electrically safe ground of apparatus or equipment by electrically conductive spacers. The mounting surface of the spacer should be within MAX 8mm. ON/OFF control terminal (primary circuit) See NOTE A. + Output terminal (M4 screw) − Output terminal (M4 screw) Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) See NOTE A.
Connector Input (CN1)
T6969-A
Output (CN51)
T7093-A
● Connector for Remote ON/OFF control: CN2, CN52 (J.S.T) Connector B2B-XH-AM
Housing
Terminal Pin
XHP-2
BXH-001T-P0.6 or SXH-001T-P0.6
Alpha II DLP
FPS
*CN2 is normally shorted by JM-2W-96 (J.S.T). *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
Genesys
NOTE A: For cover & chassis type (model: ZWS150PAF/SA), remote ON/OFF control cannot be used.
HK-A
2. Terminal Connecting Method Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged. ● Input must be o when making connections. ● Connect FG terminal of input connector and mountable FG to ground terminal of the equipment. ● Output current of each connector pin must be less than 5A. (Except /T, /S models in which M4 screw is used.) ● The output load line and input line shall be separated and twisted to improve noise sensitivity.
● Remote ON/OFF control lines shall be twisted or use shielded wire. ● Use the input/output connector housing, terminal pin as specied in outline drawing. Also, use recommended crimping tool. Connector housing and terminal pin are not included with this product. ● When connecting or removing connector, do not apply stress to PCB.
JWS-P JWT
MTW RKE
ZWS150PAF
RKY
HWS
RTW
SWT UNA
ZWS150PAF/J
VS
VS-P
ZUP
ZWDPAF
ZWS150PAF/T
ZWQ
ZWS
ZWS150PAF/S
・All specifications are subject to change without notice.
ZWS -PAF
A-463
ZWS150PAF
SERIES
3. Explanation of Functions and Precautions Input Voltage Range
Alpha II DLP
FPS
Genesys HK-A
Input voltage range is single phase 85 - 265VAC (47 63Hz) or 120 - 370VDC. Input voltage which is out of specification may cause unit damage. For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 - 240VAC (50/60Hz).
Cable
Oscilloscope Bandwidth : 100MHz
Film Capacitor Elecctroly Capacitor Film Capacitor
2 Output Voltage Range
8 Series Operation
V.ADJ trimmer (VR51) that is nearby to output connector is for output voltage adjustment within the range of specications. To turn the trimmer clockwise, the output voltage will be increased. Note over voltage protection (OVP) function may trigger if the output voltage is increased excessively.
For series operation, either method (A) or (B) is possible.
HWS JWS-P JWT
MTW RKE
3 Inrush Current This series uses power thermistor to protect the circuit from inrush current. Please carefully select input switch and fuse in cases of the high temperature and the power re-input.
4 Over Voltage Protection (OVP)
UNA
Over Current Protection (OCP)
VS
VS-P ZUP
Method(A)
Method(B)
9 Parallel Operation (A)To increase the output current is not possible.
SWT
RTW
The OVP function (inverter shut down method, manual reset type) is provided. OVP function operates within the range of OVP specication. When OVP triggers, the output will be shut down. The input shall be removed for a few minutes, and then re-input for recovery of the output. OVP setting is xed and not to be adjusted externally.
RKY
Constant current limiting, automatic recovery. OCP function operates when the output current exceeds OCP specication. The output will be automatically recovered when the overload condition is cancelled. Do not operate overload or dead short conditions for more than 30 seconds, which could result in damage.
(A)
(B)To use as back-up power supply 1. Set power supply output voltage higher by the forward voltage drop (VF) of diode 2. Adjust the output voltage of each power supply to be the same. 3. Use within the specications for output voltage and output power.
ZWDPAF ZWQ
6 Over Temperature Protection (OTP) For /OTP, /JOTP, /TOTP, /SOTP models, OTP circuit is built into the power supply to prevent power supply from damage when ambient temperature over the specication.
ZWS
7 Output Ripple & Noise
ZWS -PAF
The standard specification for maximum ripple value is measured according to measurement circuit specified by JEITA-RC9131. When load lines are longer, ripple becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to use across the load terminal. The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long.
A-464
(B)
Peak Output Current For ZWS150PAF series, the peak output current should satisfy the conditions below: 1)Should not exceed the rated peak current in the specications. (eg. 12A for ZWS150PAF-24) 2)Duty cycle of the peak output current should be < 35%, and operating time of peak output current is less than 10 seconds. If the power supply is operated under convection cooling, and ambient exceeds 50℃, the following operating period for peak current is recommended. ・All specifications are subject to change without notice.
ZWS150PAF
SERIES
Ambient Temperature (℃ )
Peak current operating time
− 10 to +50℃
within 10 seconds
+ 50℃ onwards
within 5 seconds
3)The relation between peak output current with maximum average output current is dened as below:
Remote ON/OFF control can be used by following 2 modes. However, for cover and chassis type (eg. ZWS150PAF/A, /JA, /TA, /SA) cannot be used.
Using CN2 It is controlled by short or open between +R & -R of CN2. CN2 is provided in the primary circuit for ON/OFF control by means of a switch or other device. When using this connector, which is considered to be electrically connected to the mains input voltage, all the requirements of EN60950 must be met with respect to the connector, wiring and switch etc.
Ip= Peak output current Im= Minimum output current D= Duty cycle, τ/T τ= Peak output current operating time T=Period Io= Maximum allowable average output current
speications (Io should be average load after derating at various mounting and ambient temperature) Formula: ZWS150PAF:
1.4×Io2>Ip2×D+Im2×(1-D)
Example Ⅰ : For ZWS150PAF-24 at Ta =60℃, Mounting A, Max Io =4.41A (after 70% Derating) 2 1.4×Io >Ip2×D+Im2×(1-D) (A): In case of Im=0, Ip=12A, D<18.9% (B): In case of Im=2A, Ip=12A, D<16.6% Example Ⅱ: Following table illustrate some peak load operation examples for ZWS150PAF-24. Please note that the actual Io in peak load operation is low .
Max allowable average load after derating by various Mounting and Ta:
Examples of peak load derating, calculated by above formula
Actual Io
In particular: 1)Basic insulation must be provided between the ON/ OFF control circuit and earth. 2)Reinforced insulation must be provided between the ON/OFF control circuit and any secondary circuit or accessible part. 3)Wiring must be routed such that damage to the insulation of the wire or additional sleeving cannot occur. 4)The switch must meet requirements for reinforced insulation from the ON/OFF control circuit to actuator/accessible parts.
Alpha II DLP
FPS
Genesys HK-A
HWS JWS-P JWT
MTW [CN2] The control mode is shown below. +R & -R Terminal condition
Output condition
Short
ON
Open
OFF
RKE
RKY
RTW
*Using CN52 At rst, remove short piece of CN2. It is controlled by the voltage applied to +R and –R. This circuit is in the Secondary (output) side of the power supply unit. Do not connect in the Primary (input) side. And this circuit is isolated from the output by a photo-coupler.
Average Load (%)
Io (A)
Ip (A) max
D max
Im (A)
Io (A)
100%
6.3
12
35.0%
2.83
6.04
90%
5.67
12
31.3%
0
3.75
80%
5.04
12
24.7%
0
2.96
70%
4.41
12
18.9%
0
2.27
60%
3.78
12
13.9%
0
1.67
+R & -R terminal condition
Output condition
50%
3.15
12
9.7%
0
1.16
SW ON (Higher than 4.5V)
ON
40%
2.52
12
6.2%
0
0.74
SW OFF (Lower than 0.8V)
OFF
30%
1.89
12
3.5%
0
0.42
External voltage level : E
External resistance : R
20%
1.26
12
1.5%
0
0.18
4.5 -12.5VDC
No required
10%
0.63
12
0.4%
0
0.05
12.5 -24.5VDC
1.5kΩ
SWT UNA VS
VS-P ZUP
[CN52] The control mode is shown below.
ZWDPAF ZWQ ZWS
Isolation Test Remote ON/OFF Control Remote ON/OFF control (CN2, CN52) function is available. Using this function allows the user to turn the output on and o without having to turn the AC input on and o.
・All specifications are subject to change without notice.
Isolation resistance between output and FG (Chassis) shall be more than 100MΩ at 500VDC. For safety operation, voltage setting of DC isolation tester must be done before the test. Ensure that it is fully discharged after the test.
ZWS -PAF
A-465
ZWS150PAF
SERIES must be gradually increased from zero to the testing value and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch on and o. Connect input and output as follows.
Alpha II DLP
FPS
Withstand Voltage This series is designed to withstand 3.0kVAC between input and output, 2.0kVAC between input and FG (Chassis) and 500VAC between output and the FG (Chassis) each for 1 minute. When testing withstand voltage, set current limit of the withstand voltage test equipment to 20mA (Output-FG (Chassis): 100mA). The applied voltage
Genesys
4. Mounting Directions
HK-A
HWS JWS-P JWT
MTW RKE
RKY
Output Derating according to the Mounting Directions Recommended standard mounting method is (A). Method (B), (C), (D), (E) are also possible. Mounting (F), (G) are prohibited. Please do not use installation method (F), where the PCB will be on the top side and heat will be trapped inside the unit. Refer to the derating below. In the following derating curve, average load (%) is percent of maximum output load (both maximum output current and maximum output power in specications). Do not exceed the load deratings.
Output Derating ● Convection cooling PCB type and with chassis type 120
100
150W 80 60 40
(A), (B)
(C), (D), (E)
20
0 -10
● PCB type
0
10
20
30
40
50
60
70
Average Load(%)
Convection
RTW
Mounting
Ta
SWT
(A)
UNA
−10 to40℃ 50℃ 55℃ 60℃
(B)
(D)
(C)
(E)
A
B
C
D
E
100
100
100
100
100
100
100
80
80
80
85
85
70
70
70
70
70
60
60
60
(F)Prohibit
With chassis and cover type
Standard Mounting
120
VS
(A)
● With chassis, with chassis&cover type
VS-P
ZUP
ZWDPAF
(A)
(B)
(C)
(D)
100 150W
80
(C), (E)
60
(B), (D) 40
20
(E) 0 -10
Standard Mounting
0
10
20
30
40
50
60
70
ZWQ
Average Load(%)
Convection Mounting Ta
ZWS (F)Prohibit
(G)Prohibit
(H)Prohibit
( I )Prohibit
−10 to15℃ 20℃ 30℃ 40℃ 50℃
A
B
C
D
E
100
100
100
100
100
100
100
95
100
95
100
80
80
80
80
80
65
65
65
65
65
50
56
50
56
ZWS -PAF
A-466
・All specifications are subject to change without notice.
ZWS150PAF
SERIES
● Forced air cooling PCB type and with chassis type
Example:
120
100
80 60 40
(A), (B), (C), (D), (E)
20
0 -10
0
10
20
30
40
50
60
70
Please leave 4mm space from the surfaces and leave 4mm space from the sides of PCB, especially from the solder surface, 8mm space is necessary. If the space is not enough, the specication of insulation and withstand voltage will not be satised.
Average Load(%)
Forced air Mounting
Alpha II DLP
FPS
A, B, C, D, E
Ta
−10 to60℃ 70℃
100 70
Genesys
With chassis and cover type
HK-A
120
100
HWS
80 60 40
FG should be connected to the earth terminal of the apparatus. If not, the EMI noise and output noise will increase.
(A), (B), (C), (D), (E)
JWS-P
JWT
20
0 -10
0
10
20
30
40
50
60
70
Hatching area is maximum permissible area of metal part for mounting. (9mm from each PCB corners)
Average Load(%)
Forced air Mounting Ta
−10 to50℃ 60℃
RKE
A, B, C, D, E
100
70
RKY
*Recommended minimum air velocity: 0.7m/s (Measured at component side of PCB, air must flow through component side.) As a reference for forced air cooling, let air flow so that the transformer T1 core temperature is lower than 85℃ .
MTW
RTW
SWT
For chassis option /L, chassis & cover option /A
2 Mounting Method PCB type Please use the mounting hole (4 holes of φ3.5) and insert the spacer (MAX φ8.0) of height over 8mm to lift the unit. Also use all 4 mounting holes for the unit installation. The vibration spec is the value taken when the unit is raised by 8mm spacers.
Recommended mounting by following holes A or B, to meet 19.6m/s 2 vibration specication. Mounting direction (F) & (G) are prohibited as shown in section 4-1. The power supply can be mounted through holes A or B. A : Embossed tapped and countersunk holes by 4-M4 screws B : φ4.5 holes and R2.25 slot hole by 3-M4 screws (For /SL and /SA models, these holes can not be used.)
VS
VS-P ZUP
ZWDPAF
UNA
ZWQ
Note: For cases where the unit is often under vibration condition, x with isolated spacer (non conductive), at the 5th hole, near C6 on the PCB. The 5th hole diameter: φ3.5mm PCB thickness: 1.6mm Maximum spacer outer diameter: φ7mm
・All specifications are subject to change without notice.
ZWS
Mounting (F), (G), (H), ( I ) are prohibited. For mounting method (J), (K), (L) below, the vibration specication is 6.9m/s 2, mounted through holes C or D. Note : Output derating for mounting (J) is same as mountIng (C). Output derating for mounting (K) is same as mounting (E). Output derating for mounting (L) is same as mounting (D).
ZWS -PAF
A-467
ZWS150PAF
SERIES
C: 2-φ4.5 holes and 2-R2.25 slot holes by 4-M4 screws (For/SL and /SA models, these holes can not be used.) D: Embossed tapped and countersunk holes by 2-M4 screws.
Alpha II DLP
5. Wiring Method
FPS
Genesys HK-A
HWS
● The output load line and input line shall be separated and twisted to improve noise sensitivity. ● Use all lines as thick and short as possible to make lower impedance. ● Noise can be eliminated by attaching a capacitor to the load terminals ● For safety and EMI considerations, connect FG terminal
JWS-P JWT
MTW RKE
6. External Fuse Rating Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current ows when line turns on. Use slow-blow fuse or time-lag type fuse. Do not use fast-blow fuse. Fuse rating is specied by in-rush current value at line turn-on. Do not select
RKY
RTW SWT UNA VS
of input connector and mountable FG t o ground terminal of equipment. ● Recommened screw torque is 0.49N.m (5kg.cm) ● Select the wire materials to adapt the MOLEX and J.S.T connector as follows. INPUT: AWG#22 - #18 OUTPUT: AWG#22 - #18
the fuse according to input current (rms.) values under the actual load condition. ZWS150PAF: 5A
7. Before concluding that the unit is at fault... Before concluding that the unit is at fault, make the following checks. ● Check if the rated input voltage is connected. ● Check if the wiring of input and output is correct. ● Check if the wire material is not too thin. ● Check if the output voltage control (V.ADJ) is properly adjusted. ● If you use function of the Remote ON/OFF control,
check if the Remote ON/OFF control connector is not opened. ● Check if the output current and output wattage do not exceed specication. ● Audible noise can be heard during dynamic-load operation. ● Audible noise can be heard when input voltage waveform is not sinusoidal wave.
VS-P
8. Notes
ZUP
1) Over voltage Category II.
2) Radio Interference Suppression Test is not performed.
ZWDPAF
9. Repair
ZWQ ZWS
In case of damage or repair of this product, please return to our service center or factory.
ZWS -PAF
A-468
・All specifications are subject to change without notice.
ZWS240PAF
SERIES
ZWS240PAF Series Ins tr uc ti on Manu al
BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electric shock, damage to the unit or a re hazard.
WARNING and CAUTION ● Do not modify. ● Do not touch the internal components, they may have high voltage or high temperature. You may get electric shock or burned. ● When the unit is operating, keep your hands and face away from it, you may get injured by an accident. ● This power supply is primarily designed and manufactured to be used and enclosed in other equipment. Stick the WARNING label for users on the system equipment and describe the notice in the instruction manual. ● Never operate the unit under over current or shorted conditions for 30 seconds or more and out of input voltage range in specication which could result in damage or insulation failure or smoking or burning. ● Conrm connections to input/output terminals are correct as indicated in the instruction manual. ● This power supply is PC board type unit. Please hold the board edge while mounting, and do not touch the component
side. Please lift the power supply with a spacer when mounting the power supply on any surface. ● Do not drop or apply shock to power supply unit. ● This power supply is capable of providing hazardous energy output (240VA), the end equipment manuafacturer must provide protection to service personal against inadvertent contact with output terminals. These terminals must not be user accessible. ● This power supply has a possibility that hazardous voltage may occur in output terminal depending on failure mode. The outputs of these products must be earthed in the end use equipment to maintain SELV. If the outputs are not earthed, it must be considered hazardous and must not be made user accessible
Alpha II DLP
FPS
Genesys HK-A
HWS
Note : CE MARKING CE Marking, when applied to a product covered by this handbook, indicates compliance with the low voltage directive (73/23/EEC) as modified by the CE Marking Directive (93/68/EEC) which complies with EN60950.
JWS-P JWT
MTW
1. Terminal Explanation
RKE
RKY
1 ZWS240PAF
RTW
SWT
UNA VS
AC Input terminal (pin 6 of CN1) ● Input & output connector (MOLEX) Live line (fuse in line) (also for option model /L, /A) ② N: AC input terminal (pin 4 of CN1) Connector Housing Terminal Pin Neutral line 5239-06 ③ FG: Input terminal FG (pin 1 of CN1) Input 5414-30B or 2139-06 5167PBTL (CN1) Safety earth (Frame Ground) or 3069-06 Connect to safety ground of apparatus or equipment. 5239-08 Output 5167PBTL (CN51) 5273-08A or 2139-08 ④ FG: Frame Ground (Connected to pin 1 of CN1) or 3069-08 Must be connected to electrically safety ground of ap*Output current of each connector pin must be less than 5A. paratus or equipment by electrically conductive spac*Hand crimping tooling : JHTR2445A (MOLEX) ers. The mounting surface of the spacer should be ● Connector for remote ON/OFF control: within MAX 8mm. ⑤ CN2: ON/OFF control terminal (primary circuit) CN2, CN52 (J.S.T) See NOTE A Terminal Pin Connector Housing ⑥ +: +Output terminal BXH-001T-P0.6 ⑦ −: - Output terminal B2B-XH-AM XHP-2 or SXH-001T-P0.6 ⑧ V.ADJ: Output voltage adjust trimmer (VR51) *CN2 is normally shorted by JM-2W-96 (J.S.T). The output voltage rises when a trimmer is turned *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T) clockwise. ⑨ CN52: ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) See NOTE A NOTE A: For cover & chassis type (model: ZWS240PAF/A), remote ON/OFF control cannot be used. ① L:
・All specifications are subject to change without notice.
VS-P ZUP
ZWDPAF ZWQ ZWS
ZWS -PAF
A-469
ZWS240PAF
SERIES
ZWS240PAF/J
Alpha II DLP
AC Input terminal (pin 1 of CN1) ●Input & output connector (J.S.T) Live line (fuse in line) (also for option model /JL, /JA) ② N: AC input terminal (pin 3 of CN1) Connector Housing Terminal Pin Neutral line Input B3P-5-VH VHR-5N SVH-21T-P1.1 (CN1) ③ FG: Input terminal FG (pin 5 of CN1) Output B8P-VH VHR-8N SVH-21T-P1.1 (CN51) Safety earth (Frame Ground) *Output current of each connector pin must be less than 5A. Connect to safety ground of apparatus or equipment. *Hand crimping tool : YC-160R (J.S.T) ④ FG: Frame Ground (Connected to pin 5 of CN1) Must be connected to electrically safety ground of ap●Connector for remote ON/OFF control: paratus or equipment by electrically conductive spacCN2, CN52 (J.S.T) ers. The mounting surface of the spacer should be within MAX 8mm. Connector Housing Terminal Pin ⑤ CN2: ON/OFF control terminal (primary circuit) BXH-001T-P0.6 B2B-XH-AM XHP-2 See NOTE A or SXH-001T-P0.6 ⑥ +: +Output terminal *CN2 is normally shorted by JM-2W-96 (J.S.T). ⑦ −: -Output terminal *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T) ⑧ V.ADJ: Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ⑨ CN52: ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) with an external signal.) See NOTE A NOTE A: For cover & chassis type (model: ZWS240PAF/JA), remote ON/OFF control cannot be used. ① L:
FPS
Genesys HK-A
HWS JWS-P JWT
MTW RKE
RKY
RTW
3 ZWS240PAF/T
SWT
UNA VS
VS-P ZUP
ZWDPAF ZWQ ZWS
ZWS -PAF
① L:
AC Input terminal L (M4 screw) Live line (fuse in line) ●Input & output connector (EMUDEN) ② N: AC input terminal N (M4 screw) (also for option model /TL, /TA) Neutral line Connector ③ FG: Input terminal FG (M4 screw) Input T6957-A (CN1) Safety earth (Frame Ground) Output T7094-A (CN51) Connect to safety ground of apparatus or equipment. ④ FG: Frame Ground Must be connected to electrically safety ground of ap●Connector for remote ON/OFF control: paratus or equipment by electrically conductive spacCN2, CN52 (J.S.T) ers. The mounting surface of the spacer should be Connector Housing Terminal Pin within MAX 8mm. ⑤ CN2: ON/OFF control terminal (primary circuit) BXH-001T-P0.6 B2B-XH-AM XHP-2 or SXH-001T-P0.6 See NOTE A ⑥ +: +Output terminal (M4 screw) *CN2 is normally shorted by JM-2W-96 (J.S.T). ⑦ −: -Output terminal (M4 screw) *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T) ⑧ V.ADJ: Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ⑨ CN52: ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) with an external signal.) See NOTE A NOTE A: For cover & chassis type (model: ZWS240PAF/TA), remote ON/OFF control cannot be used.
A-470
・All specifications are subject to change without notice.
ZWS240PAF
SERIES
ZWS240PAF/S
Alpha II DLP
AC Input terminal L (M4 screw) ● Input & output connector (EMUDEN) Live line (fuse in line) (also for option model /SL, /SA) ② N: AC input terminal N (M4 screw) Connector Neutral line Input T6969-A (CN1) ③ FG: Input terminal FG (M4 screw) Output CN51 T7093-A ( ) Safety earth (Frame Ground) Connect to safety ground of apparatus or equipment. ④ FG: Frame Ground ● Connector for remote ON/OFF control: Must be connected to electrically safety ground of apCN2, CN52 (J.S.T) paratus or equipment by electrically conductive spacers. The mounting surface of the spacer should be Terminal Pin Connector Housing within MAX 8mm. BXH-001T-P0.6 B2B-XH-AM XHP-2 ⑤ CN2: ON/OFF control terminal (primary circuit) or SXH-001T-P0.6 See NOTE A *CN2 is normally shorted by JM-2W-96 (J.S.T). ⑥ +: +Output terminal (M4 screw) *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T) ⑦ −: -Output terminal (M4 screw) ⑧ V.ADJ: Output voltage adjust trimmer (VR51) The output voltage rises when a trimmer is turned clockwise. ⑨ CN52: ON/OFF control terminal (secondary circuit) (For power supply output on and o control with an external signal.) See NOTE A NOTE A: For cover & chassis type (model: ZWS240PAF/SA), remote ON/OFF control cannot be used. ① L:
FPS
Genesys HK-A
HWS JWS-P JWT
MTW RKE
RKY
RTW
2. Terminal Connecting Method Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged. ● Input must be o when making connections. ● Connect FG terminal of input connector and mountable FG to ground terminal of the equipment. ● Output current of each connector pin must be less than 5A. (Except /T, /S models which M4 screw is used.) ● The output load line and input line shall be separated and twisted to improve noise sensitivity. ● Remote ON/OFF control lines shall be twisted or use shield-
SWT
ed wire. ● Use the input/output connector housing, terminal pin as specied in outline drawing. Also, use recommended crimping tool. Connector housing and terminal pin is not included with this product. ● When connecting or removing connector, do not apply stress to PCB.
UNA VS
VS-P ZUP
ZWDPAF
ZWS240PAF
ZWQ
ZWS
ZWS -PAF
・All specifications are subject to change without notice.
A-471
ZWS240PAF
SERIES
ZWS240PAF/J
Alpha II DLP
ZWS240PAF/T
FPS
Genesys
HK-A
HWS JWS-P
ZWS240PAF/S
JWT
MTW
RKE
RKY
RTW
3. Explanation of Functions and Precautions
SWT UNA VS
VS-P ZUP
ZWDPAF ZWQ ZWS
1 Input Voltage Range
Over Voltage Protection (OVP)
Input voltage range is single phase 85 - 265VAC (47 63Hz) or 120 - 370VDC. Input voltage which is out of specification may cause unit damage. For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 - 240VAC (50/60Hz).
The OVP function (Inverter shut down method, manual reset type) is provided. OVP function operates within the range of OVP specications. When OVP triggers, the output will be shut down. The input shall be removed for a few minutes, and then re-input for recovery of the output. OVP setting is xed and not to be adjusted externally.
Output Voltage Range
5 Over Current Protection (OCP)
V.ADJ trimmer (VR51) that is nearby to output connector is for output voltage adjustment within the range of specications. To turn the trimmer clockwise, the output voltage will be increased. Note over voltage protection (OVP) function may trigger if the output voltage is increased excessively.
Constant current limiting, automatic recovery. OCP function operates when the output current exceeds OCP specications. The output will be automatically recovered when the overload condition is cancelled. Do not operate overload or dead short conditions for more than 30 seconds, which could result in damage.
3 Inrush Current ZWS -PAF
This series has used Power Thermistor to protect the circuit from Inrush Current. Please carefully select input switch and fuse in cases of the high temperature and reinput the power.
A-472
6 Over Temperature Protection (OTP) OTP circuit is built into the power supply to prevent power supply from damage when ambient temperature over the specication.
・All specifications are subject to change without notice.
ZWS240PAF
SERIES
7 Output Ripple & Noise The standard specification for maximum ripple value is measured according to measurement circuit specified by JEITA-RC9131. When load lines are longer, ripple becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to use across the load terminal. The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long.
2)Duty cycle of the peak output current should be < 35%, and operating time of peak output current is less than 10 seconds. If the power supply is operated under convection cooling, and ambient exceeds 45℃, the following operating period for peak current is recommended. Ambient Temperature (℃)
Peak current operating time
45℃ −10 to +
within 10 seconds
+45℃ onwards
within 5 seconds
Alpha II DLP
3)The relation between peak output current with average output current is dened as below:
Genesys
HK-A
8 Series Operation For series operation, either method (A) or (B) is possible.
Method ( A )
Method ( B )
9 Parallel Operation (A)To increase the output current is not possible.
Ip=Peak output current Im=Minimum output current D=Duty cycle,τ/T τ=Peak output current operating time T=Period Io=Maximum allowable average output current of specications (Io should be average load after derating at various mounting and ambient temperature)
Formula: ZWS240PAF: 1.5×Io2≧Ip2×D+Im2× (I-D)
HWS JWS-P JWT
MTW RKE
Example I : For ZWS240PAF-24 at Ta=60℃, Mounting A, Max Io = 6A (after 60% Derating) 1.5×Io2≧Ip2×D+Im2×(1-D) (A): In case of Im=0, Ip=20A, D ≦ 13.5% (B): In case of Im=4A, Ip=20A, D ≦ 9.9% Example II: Following table illustrate some peak load operation examples for ZWS240PAF-24. Please note that the actual Io in peak load operation is low.
RKY
RTW SWT UNA
(A)
(B)To use as back-up power supply 1. Set power supply output voltage higher by the forward voltage drop (VF) of diode 2. Adjust the output voltage of each power supply to be the same. 3. Use within the specications for output voltage and output power.
Max allowable average load after derating by various Mounting and Ta:
Examples of peak load derating, calculated by above formula
Average Load (%) Io( A) Ip( A)max
Actual Io
VS
D max
Im ( A)
Io ( A)
100%
10
20
35.0%
3.92
9.55
90%
9
20
30.4%
0
6.08
80%
8
20
24.0%
0
4.80
70%
7
20
18.4%
0
3.68
60%
6
20
13.5%
0
2.70
50%
5
20
9.4%
0
1.88
40%
4
20
6.0%
0
1.20
30%
3
20
3.4%
0
0.68
20%
2
20
1.5%
0
0.30
10%
1
20
0.4%
0
0.08
(B)
Peak Output Current For ZWS240PAF series, the peak output current should satisfy the conditions below: 1)Should not exceed the rated peak current in the specications. (eg. 20A for ZWS240PAF-24)
VS-P ZUP
ZWDPAF ZWQ ZWS
・All specifications are subject to change without notice.
FPS
Remote ON/OFF Control Remote ON/OFF control (CN2, CN52) function is available. Using this function allows the user to turn the output on and o without having to turn the AC input on and o. Remote ON/OFF control can be used by following 2 modes. However, for Cover and Chassis type (eg. ZWS240PAF/A, /JA, /TA, /SA) cannot be used.
ZWS -PAF
A-473
ZWS240PAF
SERIES
Using CN2
Alpha II DLP
FPS
Genesys HK-A
HWS JWS-P
It is controlled by short or open between +R & -R of CN2. CN2 is provided in the primary circuit for ON/OFF control by means of a switch or other device. When using this connector, which is considered to be electrically connected to the mains input voltage, all the requirements of EN60950 must be met with respect to the connector, wiring and switch etc. In particular: 1)Basic insulation must be provided between the ON/ OFF control circuit and earth. 2)Reinforced insulation must be provided between the ON/OFF control circuit and any secondary circuit or accessible part. 3)Wiring must be routed such that damage to the insulation of the wire or additional sleeving cannot occur. 4)The switch must meet requirements for reinforced insulation from the ON/OFF control circuit to actuator/accessible parts. [CN2] The control mode is shown below. +R & -R Terminal condition
JWT
MTW
Output condition
Short
ON
Open
OFF
Using CN52 RKE
RKY
RTW
At rst, remove short piece of CN2. It is controlled by the voltage applied to +R and –R. This circuit is in the Secondary (output) side of the power supply unit. Do not connect in the Primary (input) side. And this circuit is isolated from the output by a photo-coupler.
External voltage level: E
External resistance: R
4.5 -12.5VDC
No required
12.5 -24.5VDC
1.5kΩ
Isolation Test Isolation resistance between output and FG (Chassis) shall be more than 100MΩ at 500VDC. For safety operation, voltage setting of DC isolation tester must be done before the test. Ensure that the it is fully discharged after the test.
Withstand Voltage This series is designed to withstand 3.0kVAC between input and output, 2.0kVAC between input and FG (Chassis) and 500VAC between output and the FG (Chassis) each for 1 minute. When testing withstand voltage, set current limit of the withstand voltage test equipment to 20mA (Output-FG (Chassis): 100mA). The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch on and o. Connect input and output as follows.
SWT
UNA
[CN52] The control mode is shown below. VS
+R & -R terminal condition
VS-P
Output condition
SW ON (Higher than 4.5V)
ON
SW OFF (Lower than 0.8V)
OFF
ZUP
ZWDPAF
4. Mounting Directions 1 Output Derating according to the Mounting Directions
● PCB type
ZWQ ZWS
ZWS -PAF
Recommended standard mounting method is (A). Method (B), (C), (D), (E) are also possible. Mounting (F), (G), (H), (I) are prohibited. Please do not use installation method (F), where the PCB will be on the top side and heat will be trapped inside the unit. Refer to the derating below. In the following derating curve, average load (%) is percent of maximum output load (both maximum output current and maximum output power in specications). Do not exceed the load deratings.
A-474
(A)Standard Mounting (B)
(C) (D)
(E) (F)Prohibited
・All specifications are subject to change without notice.
ZWS240PAF
SERIES
● With chassis, with chassis&cover type
● Forced air cooling PCB type and with chassis type
100
(A)Standard Mounting
(B)
(C)
(D)
(E)
80 60 40
Mounting (A), (B), (C), (D), (E)
Alpha II DLP
20
(G)Prohibit
(F)Prohibited
(H)Prohibit
(I)Prohibit 0 -10
0
10
20
30
40
50
60
FPS
70
Output Derating ● Convection cooling PCB type and with chassis type
A, B, C, D, E
−10 to60℃ 70℃
120
Genesys
(%) Average Load
Forced air Mounting Ta
100
HK-A
70
100
With chassis and cover type
240W
80 60 40 20
HWS
100
0 -10
0
10
20
30
40
50
60
70
Convection Mounting Ta
−10 to25℃ 30℃ 35℃ 40℃ 45℃ 50℃ 55℃ 60℃
JWS-P
80 60 40 20
JWT
Mounting (A), (B), (C), (D), (E)
MTW RKE
0
(%) Average Load
-10
A
B
C
D
E
100
100
100
100
100
100
100
100
100
87.5
100
100
90
90
75
100
93.3
80
80
62.5
100
86.7
70
70
50
86.7
80
60
60
37.5
73.3
60
50
50
25
60
40
40
40
12.5
With chassis and cover type
0
10
20
40
50
60
RKY
(%) Average Load
Forced air Mounting Ta
−10 to50℃ 60℃
A, B, C, D, E
RTW
100 70
*Recommended minimum air velocity: 0.7m/s (Measured at component side of PCB, air must flow through component side). As a reference for forced air cool ing, let air flow so that the transformer T1 core temperature is lower than 80℃
120
30
SWT UNA
100
240W
80 60 40 20 0 -10
0
10
20
30
VS
VS-P ZUP
40
50
60
70
ZWDPAF
Ta
Mounting
−10 to5℃ 15℃ 25℃ 50℃
ZWQ
(%) Average Load
Convection A
B
C
D
E
100
100
100
100
100
100
100
100
80
80
100
80
80
60
60
50
30
30
10
10
ZWS
ZWS -PAF
・All specifications are subject to change without notice.
A-475
ZWS240PAF
SERIES
Mounting Method
PCB type
Alpha II
Please use the mounting hole (5 holes of φ3.5) and insert the spacer (MAX φ8.0) of height over 8mm to lift the unit. Also use all 5 mounting holes for the unit installation. The vibration spec is the value taken when the unit is raised by 8mm spacers.
Hatching area is maximum permissible area of metal part for mounting.
DLP
FPS
Genesys HK-A
HWS
For chassis option /L, chassis & cover option /A
Please leave 4mm space from the surfaces and leave 4mm space from the sides of PCB, especially from the solder surface, 8mm space is necessary. If the space is not enough, the specication of insulation and withstand voltage will not be satised.
JWS-P
Recommended mounting by following holes A or B, to meet 19.6m/s2 vibration specication. Mounting direction (F) & (G) are prohibird as shown in section 4-1. A: Embossed tapped and countersunk holes by 4-M4 screws B: φ4.5 holes and R2.25 slot hole by 3-M4 screws (For /SL and /SA models, these holes can not be used)
JWT
MTW
RKE
FG should be connected to the earth terminal of the apparatus. If not, the EMI noise and output noise will increase.
RKY
5. Wiring Method
RTW SWT UNA VS
VS-P
● The output load line and input line shall be separated and twisted to improve noise sensitivity. ● Use all lines as thick and short as possible to make lower impedance. ● Noise can be eliminated by attaching a capacitor to the load terminals. ● For safety and EMI considerations, connect FG terminal of input connector and mountable FG to ground terminal
of equipment. ● Recommened screw torque is 0.49N.m (5kg.cm) ● Select the wire materials to adapt the MOLEX and J.S.T connector as follows. INPUT: AWG#22 - #18 OUTPUT: AWG#22 - #18
ZUP
6. External Fuse Rating
ZWDPAF ZWQ ZWS
Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current ows when line turns on. Use slow-blow fuse or time-lag type fuse. Do not use fast-blow fuse. Fuse rating is specied by in-rush current value at line turn-on. Do not select the fuse according to input current (rms.) values under the actual load condition.
ZWS240PAF: 6.3A
ZWS -PAF
A-476
・All specifications are subject to change without notice.
ZWS240PAF
SERIES
7. Before concluding that the unit is at fault... Before concluding that the unit is at fault, make the following checks. ● Check if the rated input voltage is connected. ● Check if the wiring of input and output is correct. ● Check if the wire material is not too thin. ● Check if the output voltage control (V.ADJ) is properly adjusted. ● If you use function of the Remote ON/OFF control,
check if the Remote ON/OFF control connector is not opened. ● Check if the output current and output wattage do not over specication. ● Audible noise can be heard during dynamic-load operation. ● Audible noise can be heard when input voltage waveform is not sinusoidal wave.
Alpha II DLP
FPS
8. Notes 1)Over voltage Category II. 2)Radio Interference Suppression Test is not performed.
Genesys HK-A
HWS
9. Repair In case of damage or repair of this product, please return to our service center or factory.
JWS-P JWT
MTW RKE
RKY
RTW SWT UNA VS
VS-P ZUP
ZWDPAF ZWQ ZWS
ZWS -PAF
・All specifications are subject to change without notice.
A-477