Architectural Design & Site Planning (ADSP) Sample Questions PART ONE
Q1 Light not recommended for factory?
a. LED b. surface mounted CFL c. pendant d. high heat halogen
Q2 At what stage should you consider Tropical Design Concepts?
a.
At the very onset, during the Pre-Design Stage
b. Anytime, during the Design Development Stage c.
During Contract Documentation
Q3 Which flooring material is NOT the most economical? a.
China granite tiles
b. Italian granite slab c.
Italian granite tiles
d. Locally manufactured granite tiles
Q4 What type of ( R-1 Use) foundation should be ideal if the lot is sloping upwards? a.
Combined
b. Mat c.
Isolated
d. Retaining Wall
Q5 Given its orientation, what are the dominant sun-paths for the property? a. SE to SW and NE to NW b. SE to NW and NE to SW c. SW to SE and NW to NE d. SE to NW and NE to SW
Q6 Which of the following is NOT the most economical? a.
China Granite Slab
b. Italian Granite Slab c.
Italian Granite Tiles
d. China Granite Tiles
Q7 What type of paint should not be used as a finish for enclosed interior spaces? a. QDE b. Latex c. Automotive lacquer d. Epoxy
Q8 At what stage should you consider Site Analysis?
a.
At the very onset, during the Pre-Design Stage
b. Anytime, during the Design Development Stage c.
During Contract Documentation
Q9 Which of the following is NOT considered furniture?
a.
Sofa
b. Table c.
Curtain
d. Lampshade
Q10 Which of the following is NOT considered as an architectural interior (AI) element for the project? a. eaves b. unit party wall c. elevator lobby ceiling d. bathroom floor
Q11 Material that typically has a 5-year warranty?
a. Laminated flooring b. Roof deck waterproofing c. Toilet waterproofing d. Awning window
Q12 For R-1 development, what is the maximum height of a perimeter wall? a.
2.70 m
b. 2.40 m c.
3.00 m
d. 3.20 m
Q13 Which is the first activity?
a. architectural design preparation b. plan preparation c. building code requirements check d. space plan preparation
Q14 At what stage should you consider Programming? a.
At the very onset, during the Pre-Design Stage
b. Anytime, during the Design Development Stage c.
During Contract Documentation
Q15 Which is NOT an equipment? a.
Exhaust Fan
b. Hand Dryer c.
CCTV
d. Soap Dispenser
Q16 Which is not part of the AMBF?
a. Basement b. Lobby c. Covered Parking d. Foyer
Q17 Area of bedside table (in sq. meter)?
a. 0.22 b. 0.11 c. 0.44 d. 0.33
Q18 Which of the following is NOT a furniture? a.
Dresser
b. Couch c.
Flat LED TV
d. Divan
Q19 Which is not part of the GFA? a. Roof deck b. Balcony c. Open Garage d. Basement
Q20 Area for single bed (in sq. meter)?
a. 1.425 b. 1.52 c. 1.71 d. 1.90
Q21 Which of the following is NOT an executive position at the Government-Owned and Controlled Corporation (GOCC)? a.
Vice President
b. Director c.
Division Chief
d. Assistant Vice President
Q22 In a building, what do you call curtains, draperies, etc?
a.
Furniture
b. Furnishing c.
Fixtures
d. Fittings
Q23 Which should not be placed inside a building‟s basement level? a. Incinerator b. Garbage disposal c. Parking d. Electrical Room
Q24 Area for double bed (in sq. meter)?
a. 1.90 b. 2.09 c. 2.28 d. 2.85
Q25 Which of the following has the smallest carbon footprint? a. Kiln-dried wood b. Sun-baked tile c. Oven-baked tile d. Laminated wood
Q26 Which is NOT a furnishing? a.
Acrylic Painting
b. Ceiling Fan c.
Area Rug
d. Sectional Sofa
Q27 What shouldn‟t be located at the basement, if introduced?
a. MRF b. workshop c. den d. dry storage
Q28 Which will you NOT provide in a secretarial position?
a.
Side table
b. Desk c.
File Drawer
d. Executive Chair
Q29 Considering maintenance, where is the best place to position the downspouts of the roof deck? a. Embedded in columns b. CHB pipe chase c. In the exterior of building, near the columns but outside the cladding d. In the exterior of the building, but far from the columns
Q30 Considering structural stability and economy, where is the best place to position the perimeter beams of a building? a. Along the centerline of the columns b. Along the exterior face of the columns c. Along the interior face of the columns d. None of the Above
Q31 Which is NOT a Furnishing?
a.
Wall painting
b. Cornice c.
Tile Flooring
d. Shelves
Q32 Which is part of the Building Footprint?
a.
Utility Room
b. Mezzanine Level c.
Balcony
d. Basement
Q33 At what stage should you consider Provisions of NBCP?
a.
At the very onset, during the Pre Design Stage
b. Anytime during the Design Development Stage c.
During Contract Documentation
Q34 Which should not be placed in the carport?
a. Hose reel b. Dog cage c. Storage cabinet d. Flower Pots
Q35 Which flooring material is the most resilient?
a.
Vinyl Sheet
b. Linoleum c.
Ceramic Tiles
d. Vinyl Tiles
Q36 Assuming the site will be on a converted rice field, on what soil must the foundation rest? a.
Hard to very hard
b. Very soft to soft c.
Medium to Hard
d. Soft to Medium
Q37 Which is NOT an indoor equipment?
a. AC window type b. exhaust fan c. split-type AC d. microwave oven
Q38 What waterproofing color is best for deck? a. Light Gray b. Black d. White e. Dark Gray
Q39 Where is a Service Area best located? a.
Side of the lot
b. Back of the house c.
Both sides of the lot
d. Front of the lot
Q40 Which of the following is NOT considered a Service provision? a.
Gardener‟s Room
b. Overhead Water Tank c.
Workshop
d. Security Quarters
Q41 Which is NOT included in the Architectural Interiors?
a. fittings b. fixtures c. fixed furniture d. built-in cabinets
Q42 Which is NOT part of Building Footprint?
a.
Exterior Walls
b. Basement c.
Lower Ground Floor
d. Podium Ground Floor
Q43 Span of two columns along driveway so that two cars can be accommodated? a. 5 meters b. 6 meters c. 4.5 meters d. 7 meters
Q44 Which of the following provisions should NOT be situated close to one another? a.
Security Quarters, Lockers and CR
b. Homeowners Association Office and Generator room c.
Guest parking, Ramps and Streets
d. Cistern and Sewage Treatment Plant
Q45 What is the best paint color for a Roofdeck?
a.
Dark gray
b. Dark Beige c.
Light Gray
d. Light Beige
Q46 What is NOT included in Topographic Maps?
a.
Elevation of Adjacent Buildings
b. Contours of Adjacent Lots c.
Natural and Man-made Features
Q47 Which is NOT included in the Architectural Interiors?
a. furnishings b. floors c. wall d. ceiling
Q48 Clear span of two columns in parking area so that 3 cars can be accommodated? a. 6 meters b. 7 meters c. 7.5 meters d. 9 meters
Q49 Which is NOT an Interior Appliance? a. exhaust fan b. electric fan c. microwave oven d. ACU
Q50 What should be the archetype for R-1 developments a.
Warm and Inviting
b. Safe and Relaxed c.
Isolated
d. With firewalls
Architectural Design & Site Planning (ADSP) Sample Questions PART TWO
Q51 Based on the example in the NBC, what is the PSO for an R-1 structure in an inside lot with an area of 301sqm? a. 50% b. 55% c. 60% d. 70%
Q52 A 4 sqm wall is to be covered with tiles. If you will use 0.30m x 0.30m tiles, how many tiles will be needed? a. 40 b. 44 c. 45 d. 50
Q53 To fit 3 vehicles per structural bay (meters times meters, center to center), which of the following should NOT be a recommended bay measurement for the Project? a.
8.55 x 9.0
b. 8.75 x 9.5 c.
9.05 x 9.8
d. 7.25 x 8.0
Q54 In Institutional Design, what color is inviting to the eyes of a person? a.
Blue
b. Green c.
White
d. Yellow Orange
Q55 What is “habagat”? a. Southwest monsoon b. Northeast monsoon c. Southeast monsoon d. Northwest monsoon
Q56 What should be the prominent line for an R-1 two-storey house with a frontage of 15m? a. horizontal b. vertical c. diagonal d. curve
Q57 What is “amihan”? a. Southwest monsoon b. Northeast monsoon c. Southeast monsoon d. Northwest monsoon
Q58 What tree is rigid, medium spread leaves, shallow rooted, small diameter roots, not resistant to strong winds and may be a hazard if planted near a building? a. palm tree b. coconut c. mahogany d. acacia
Q59 Area of a junior executive table? a. 0.54 sqm b. 0.84 sqm c. 1.35 sqm d. 1.8 sqm
Q60 What tree is medium trunk, medium spread leaves, deep rooted, small diameter roots, resistant to strong winds, relatively safe to plant near a building/structure? a. palm tree
b. coconut c. mahogany d. acacia
Q61 Which is NOT part of the Building Footprint?
a.
Basement
b. Ground Floor c.
Exterior Walls
d. Utility Room
Q62 At what stage should you consider provisions of RA 9514?
a.
At the very onset, during the Pre Design Stage
b. Anytime during the Design Development Stage c.
During Contract Documentation
Q63 . For a residential development, what is the best location of a downspout? a.
Center of the House
b. Property Walls c.
Rear of the House
d. Sides of the House
Q64 Trees are best placed in which side of the building? a. North-south b. Northeast c. Southwest d. East-west
Q65 Which is NOT a good characteristic of a tree that can be harmful in the site? a. arboreal b. shallow root c. ball or rounded root d. deep root
Q66 Where do easterly winds come from? a. East b. West c. Southwest d. Northeast
Q67 Assuming the site will be on a flood plain, on what soil must the foundation rest? a.
Hard to very hard
b. Very soft to soft c.
Medium to Hard
d. Soft to Medium
Q68 In terms of material production, which of the following flooring materials is considered to have the lowest carbon footprint? a. baked clay tiles b. hand-cut natural stone c. high-pressure laminate flooring d. ceramic tiles
Q69 Which is the best exterior finishing material for south portion of building? a. Transparent glass with thick dark-colored masonry b. Stone veneer on 6” CHB c. White-painted plastered 4” CHB walls d. Low-e glass curtain walls
Q70 How much tee runner angle section (in lineal meters) is required for the same 4.00 m x 6.10 m conference room? a.
20.2
b. 22.2 c.
21.2
d. 19.2
Q71 Assuming the site will be on Adobe soil, what foundation will you use? a.
Bored Pile
b. Sheet Pile c.
Isolated Footing
d. Footings with Tie Beams
Q72 Assuming a heavily forested location for the Project Site, what type of roof structure should be introduced? a. steel deck roof b. steep gable roof c. RC Deck Roof d. low-slope Metal Roofing on Space frame
Q73 For project # 2, under the NBCP, which is part of the GFA for the Project? a.
Roof deck, if introduced
b. Lobby c.
Covered Parking
d. ACCU Balcony
Q74 What is part of BHL? a.
Parapet
b. Mast c.
Signage
d. Antenna
Q75 Which is not an interior installation? a. Exhaust fan b. Air-conditioning unit c. Hand dryer d. Microwave
Q76 Which other use can best complement a private 10-unit cluster housing compound? a. Entertainment b. Private business c. Home office d. Educational
Q77 What type of paint is normally not sprayed? a. Latex b. QDE c. Automotive lacquer d. Epoxy
Q78 If the residential condominium units are to be air-conditioned, what shall be the minimum distance (in meters) between the finished floor line (FFL) and the finished ceiling line (FCL)? a) 2.44
b) 2.24 c) 2.10 d) 1.90
Q79 Maximum height of (R-1) wall for fence without beam above grade
a.
1.20
b. 1.80 c.
2.00
d. 3.20
Q80 Where is the best orientation of bedrooms?
a.
North
b. East c.
South
d. West
Q81 Where should be the main drainage, electrical service entrance, and main sewer line be located? a. Within the property line
b. At the setback c. Along property line d. At the easement
Q82 Which of the following is a hardware?
a) Door frame b) Door jamb c) Door leaf d) Door stop
Q83 What foundation presents the LEAST disturbance & potential damage to neighboring lots? a.
Bored Pile
b. Sheet Pile c.
Isolated Footing
d. Footings with Tie Beams
Q84 What kind of Treatment should best fit the Façade of a Garment Factory? a.
More on Concrete with less Glass and Steel
b. More on Glass and Steel with less concrete c.
Combination of Concrete and Plastic
d. More on Steel
Q85 The measurement of the percentage of site occupancy is taken at what level? a. at sidewalk level b. at street level c. at ground level d. at curb level
Q86 What can you NOT provide in a pinlight housing? a.
100W Incandescent
b. 20W CFL c.
LED
d. 40W CFL
Q87 Which side of the structure will be exposed to the Sun for approximately 4 months? a.
North
b. South c.
East
d. West
Q88 Why wouldn‟t you use mercury vapor lamp on the living room? a.
Because it will be very bright
b. It is too expensive c.
It is too big
Q89 Which is not good for counter depth?
a) 0.30m b) 0.40m c) 0.45m d) 0.55m
Q90 What kind of Treatment should best fit the Façade of a Government Office Building? a.
More on Concrete with less Glass and Steel
b. More on Glass and Steel with less Concrete c.
Combination of Concrete and Plastic d. More on Steel
Q91 To achieve economy in design, where should the Downspout of an (C-2) Office Building be located? a.
Rear portion of the building
b. Sides of the building c.
At the center of the building
d. At Perimeter Wall
Q92 The Kitchen Area is best oriented where? a. South sector b. Southwest sector c. West sector d. Northwest sector
Q93 What foundation presents the MOST disturbance & potential damage to neighboring lots? a.
Bored Pile
b. Sheet Pile c.
Isolated Footing
d. Footings with Tie Beams
Q94 Which of the following is part of the GFA? a.
Maid‟s Room
b. Basement Parking c.
Carport
d. Cooling Tower
Q95 In a crowded and noisy hallway, which will you NOT provide in terms of acoustical treatment? a.
Carpet
b. Gypsum Board c.
Curtains
d. Glass
Q96 For a proposed 4-storey residential condominium project, which of the following would you specify for the Lobby Flooring? a.
Granite
b. Ceramic Tiles c.
Vinyl
d. Carpet
Q97 Which is not a hardware finish?
a) Diamond or tooled b) Coarse hard sand c) Stainless steel d) Polished brass
Q98 What is the paving material commonly used for Parking Areas?
a.
Rough finish concrete
b. Asphalt c.
Gravel
d. Macadam
Q99 The Bedrooms are best located where? a. South sector b. Southwest sector c. Northeast sector d. Northwest sector
Q100 Which is not a millwork?
a) baseboard b) Cornice moulding c) Closet drawer d) Chair rail
Architectural Design & Site Planning (ADSP) Sample Questions PART THREE
Q101 At what stage should you consider Provisions of BP 344?
a.
At the very onset, during the Pre Design Stage
b. Anytime during the Design Development Stage c.
During Contract Documentation
Q102 For a 4-storey residential condominium project, which of the following is the most economical but elegant flooring material for the Lobby?
a.
Granite Slab
b. Concrete Slab c.
Granite Tiles
d. Synthetic Granite Tiles
Q103 What is the most common structural system presently employed in a medium – high-rise apartment construction? a. flat-plate cast-in-place reinforced concrete with randomly placed columns b. steel structural frames c. masonry and CHB for external envelope and drywall for internal partitions
d. none of the above
Q104 Preferred plaster thickness of exterior CHB?
a) 0.19m b) 0.14m c) 0.29m d) 0.24m
Q105 As a rule of thumb, spacing between concrete columns may economically be in the range of what? a. 12‟ – 18‟ on center b. 14‟ – 16‟ on center c. 12‟ – 14‟ on center d. none of the above
Q106 Which of the following does NOT allow surface water percolation?
a) Fine sand b) Poured or cast on-site concrete c) asphalt d) Coarse gravel
Q107 . Which side of the structure will be exposed to the Sun for approximately 8 months? a.
North
b. South c.
East
d. West
Q108 The required building exterior shall be along classical, neoclassical or stylized classical lines combined with modern features. What primary architectural element should be considered? a. Columns b. External Corridor c. Main entrance to building d. decorative motif of facade
Q109 For a 4-storey residential condominium project, which of the following would you specify for the Units Kitchen Counter?
a.
Polyethylene
b. Granite c.
Ceramic
d. Laminated chipboard
Q110 Which is impervious?
a) Ceramic tile on concrete slab b) Gravel and sand c) Earth and soil d) Asphalt on gravel base coarse
Q111 What is the preferred modular dimensions for a single bed? a. 1.00 M x 1.80 M with 0.40 circulatory areas on both sides of the bed b. 0.90 M x 2.00 M with 0.40 circulatory areas on both sides of the bed c. 0.90 M x 2.00 M with 0.40 circulatory areas on one side of the bed d. 0.90 M x 2.00 M with 0.40 circulatory areas on both sides of the bed and 0.50 at foot of the bed
Q112 Which is NOT impervious?
a) soil b) Pebble washout c) Unpolished granite slab d) Concrete slab-on-fill
Q113 What is a preferred modular dimensions for a double bed? a. 1.50 M x 2.00 M with 0.70 M circulation area on both sides of the bed b. 2.00 M x 2.00 M with 0.70 M circulation area on both sides of the bed and 0.40 M at the foot of the bed c. 1.50 M x 2.00 M with 0.70 M for side lamp tables on both sides of the bed and 0.50 M at the foot of the bed
d. 1.50 M x 2.00 M with 0.50 M for side lamp tables on both sides of the bed and 0.50 M at the foot of the bed
Q114 Which is NOT an earth color for painting walls?
a) green b) blue c) brown d) white
Q115 What type of road finish is best when heavy rain is pouring? a.
Cast concrete
b. Asphalt c.
Gravel
d. Dirt
Q116 From the list of floor finishes, what would be best for the bedroom/sleeping area? a. vinyl tiles b. wood tile c. carpet tiles d. ceramic tiles
Q117 Wall footing width for 3m high wall?
a) 0.30m b) 0.40m c) 0.50m d) 0.60m
Q118 What is the best style for a Government Building if there is a limited budget? a.
Neo-Classical
b. Modern Lines c.
Mediterranean
d. Classical
Q119 What‟s the best thing to provide to serve as natural buffer on the SW orientation? a.
Provide wide setbacks
b. Provide broad canopied trees c.
Provide artificial wind buffers
Q120 Which of the following is NOT part of the GFA?
a.
Maid‟s Room
b. Hallway c.
Elevator Lobby
d. Carport
Q121 Which is NOT resilient? a. vinyl strip b. vinyl tile c. ceramic tile d. linoleum
Q122 At what stage should you consider Provisions of RA 9266? a.
At the very onset, during the Pre design Stage
b. Anytime during the Design Development Stage c.
During Contract Documentation
Q123 What will be the best Roofing for an Industrial Structure that sits near a River? a.
Steel Deck
b. Concrete Roof Deck c.
Steel Roof
Q124 Which of the following structural elements can be erected along a side or rear property line if the property is resting on relatively flat terrain? a. firewalls and perimeter b. end wall c. retaining wall d. zocalo wall
Q125 Which light is not good for an office?
a) LED b) pendant c) Surface mounted d) Mercury vapor
Q126 What is the 1.00 M. additional height required for the BHL? a. height of parapet from roof deck/slab/ceiling of the upper level b. Elevation from the sidewalk to the ground floor level c. Elevation from the rear of the lot d. Elevation from grade line
Q127 If the Apartment is 4-Storey, how many elevators will be used? a.
1
b. 2 c.
4 (for each floor)
d. 0 (limited budget)
Q128 Which is a noble color for an office?
a) Dark blue b) black c) gray d) white
Q129 What will be the best Roofing for a Residential structure that sits near a River? a.
Steep Aluminum Roof
b. Slightly Steep Gable Roof c.
Roof Deck
Q130 What directions should be maximized to take the advantage of maximizing the cooling effect of prevailing winds coming from the southeasterly and southwesterly directions? a. North-South exposure
b. NE-SW exposure c. East-West exposure d. North exposure alone
Q131 Which of the following is NOT to be located at the basement?
a.
Sump Pit
b. MRF c.
Maintenance
d. Storage Room
Q132 Which is not required in a Senior Manager‟s Area?
a) File room b) toilet c) Receiving area d) Senior executive desk
Q133 Which is not a facility? a. game room
b. cafeteria c. business center d. gym
Q134 Which of the following is NOT to be located at the basement? a.
Elevator Lobby
b. Electric Room c.
Solid Waste Storage
d. Parking / Ramps
Q135 For a massive factory structure, what should be the prominent architectural „lines‟ to be seen from the street? a.
Vertical
b. Horizontal c.
Diagonal
d. Curves
Q136 In a Multi-Storey Apartment, what is the best use to complement the residential area? a.
Business (Office)
b. Commercial c.
Recreational
d. Entertainment
Q137 What type of foundation should be used so that the construction would not affect the adjacent structures? a) Pile/caisson b) Strip footing c) Sheet piling d) Matt footing
Q138 Which is not a utility? a. STP b. generator room c. cistern d. parking
Q139 What should be the ideal treatment for the facade of the Warehouse? a.
Glass and Concrete
b. More on steel c.
More on Concrete and Less Glass
d. Concrete and some Plastic
Q140 Highest position?
a) Vice President b) Executive Vice President c) Assistant Vice President d) Division Chief
Q141 Which is not an amenity?
a. restaurant b. condo office c. bar d. video conference room
Q142 For a proposed low-rise national government office building, what is the best use to complement the area? a.
Business Office
b. Commercial c.
Recreational
d. Entertainment
Q143 Which of the following is NOT an ideal height of a door knob?
a.
0.82 m
b. 1.06 m c.
1.02 m
d. 1.12 m
Q144 If the project site is located in a lake, what should be the ideal roofing material? a.
Concrete (deck)
b. Long Span G.I c.
Asphalt Shingles
d. Steel deck
Q145 Which is NOT a service provision?
a) Safe and security office b) Executive lounge c) Maintenance room d) Motor pool
Q146 Which is not a service provision? a. security office b. AHU room c. water tank d. workshop/carpentry room
Q147 What type of road finish has the least traction when heavy rain is pouring? a.
Cast concrete
b. Asphalt c.
Gravel
d. Dirt
Q148 What plan guides the design of a structure? a.
CLUP
b. Zoning c.
Land Use
d. Physical Plan
Q149 What paint color is NOT recommended for the exterior of a Firewall?
a) Light Gray to Medium Gray b) Dark Gray c) Black d) Beige
Q150 Where will you locate Trees as Buffers from the “Habagat” wind? a.
East, Southeast and Southern part
b. North, Northeast and Eastern part c.
West, Northwest and Northern part
d. West, Southwest and Southern part
Architectural Design & Site Planning (ADSP) Sample Questions PART FOUR
Q151 Ideal size of one side of a square table for 8 persons? a.
1.22 m
b. 1.33 m c.
1.11 m
d. 1.44 m
Q152 At what stage should you consider provisions of NBCP Rules 7&8? a.
At the very onset, during the Pre design Stage
b. Anytime during the Design Development Stage c.
During Contract Documentation
Q153 Which of the following is NOT part of the GFA? a.
Balcony
b. Basement Parking c.
Elevator Lobby
d. Hallway
Q154 Which is not a service provision?
a. safe and security office b. maintenance room c. executive lounge d. motor pool
Q155 If there are 2 cars in between columns, which cannot be the clear span distance between columns? a) 4.80 m b) 5.40 m c) 6.00 m d) 7.20 m
Q156 Which of the following gives general high amount of reflected light and heat? a. red brick b. poured or cast on-site concrete c. asphalt d. coarse gravel
Q157 Where should the excavation start, if the structure has a basement?
a) front b) rear c) middle d) side
Q158 What would be the size of a side table? a.
0.40 x 0.40 m
b. 0.50 x 0.50 m c.
0.30 x 0.30 m
d. 0.45 x 0.45 m
Q159 What is NOT included in the Design Development Stage? a.
Preparation of Technical Specifications
b. Preparation of Roof Plan c.
Preparation of Ceiling Plan
d. Finalization of Layouts & Floor Plans
Q160 Which is not an interior installation? a. Exhaust fan
b. Air-conditioning unit c. Hand dryer d. Microwave
Q161 Which of the following should NOT be provided at the basement component of the project? a. parking (below grade or lower than the elevation of the street); driveways, ramps, etc. b. elevator lobby and service stairs c. telecommunications equipment room d. garbage chute room and solid waste storage
Q162 Where on a property is the best place to plant trees to Shade the Lower floors? a.
Right and Left Side
b. Front and Rear c.
Southeast
d. Northeast
Q163 Which is NOT a neutral color?
a. gray b. blue c. black d. white
Q164 What type of window is not recommended in a high rise building?
a. Hopper b. Pivoted c. Casement d. Awning
Q165 Which is a warm color?
a. brown b. green c. yellow orange d. gray
Q166 Which is more expensive?
a) 1.22 x 2.44 Italian granite b) 0.60 x 0.60 Asian granite c) 1.00 x 2.00 Asian granite d) 0.60 x 2.40 Italian marble
Q167 Dining table in square meters for 8 persons? a. 1.33 b. 1.22 c. 1.44 d. 1.11
Q168 Shall not precede the architectural design activity for the project?
a. specifications b. end-user identification c. architectural programming d. space planning
Q169 What type of road finish will emit less Radiant Heat? a.
Asphalt
b. Concrete c.
Earth/Soil
d. Macadam
Q170 Which tree is the best to locate beside the building? a.
Palm Tree
b. Coconut c.
Mahogany
d. Acacia
Q171 Which is not a sanitary spatial provision?
a. sump pit and sump pump b. STP c. pump room d. solid waste storage
Q172 Which is not a good keyhole height from FFL?
a. 0.975 m b. 0.963 m c. 1.055 m d. 1.55 m
Q173 Which is not a facility provision? a.
mess hall
b. commissary/grocerette c. kitchen d.
multipurpose room
Q174 Under the National Building Code of the Philippines (NBCP), which is NOT part of the Gross Floor Area (GFA) for the Project? a.
Elevator Lobby
b. Cooling Tower Area, if Introduced c.
Balcony
d. Corridor
Q175 Deep rooted tree?
a. acacia b. mahogany c. coconut tree d. palm tree
Q176 What is the minimum elevator shaft at BP 344?
a. 1.5 x 1.8 b. 1.9 x 2.2 c. 1.3 x 1.6 d. 1.7 x 2.0
Q177 Where will you locate the sump pit in a high-rise building with basements? a.
Ground Floor
b. Upper Basement c.
Lowest Basement
Q178 What is the best paint color for exterior walls?
a) Dark gray b) Dark beige c) Light gray d) Light beige
Q179 On a swampy area, what type of soil should the foundation rest on?
a) Hard to very hard b) Very soft to soft c) Medium coarse d) sandy
Q180 Which is not provided in a Senior Manager‟s room
a. filing cabinet b. Jr. executive desk c. clerical chair d. visitor‟s chair
Q181 Which of the following is the most pervious?
a.
Lawn with macadam
b. Lawn with Carabao Grass c.
Lawn with Flagstones
d. Lawn with Pavers
Q182 Under the 1977 National Building Code of the Philippines (NBCP), what is covered by the Building Height Limit (BHL) for the Project? a) mast b) antenna c) Electrical or electronic devices mounted on top of the parapet wall, if introduced d) Deck roof level parapet wall, if introduced
Q183 Which should you use to minimize disturbance to adjoining properties? a. bored piles b. driven piles c. floating foundation d. matt foundation
Q184 Which of the following is a good lighting device for a general production area with the ceiling consisting of the soffit of a suspended slab? a) Pendant lighting (suspended incandescent lamps) b) Industrial lighting (suspended flourescent lamps with reflectors) c) Pendant lighting (suspended CFLs with housing) d) Troffer lighting (flourescent lamps with soffit-mounted lightboxes and diffusers)
Q185 Not precede architectural design? a. end-user interviews b. specifications c. space brief preparation d. architectural program
Q186 Which of the following is the most impervious? a.
Pavers with pockets for plants
b. Pavers with mortar in between c.
Pavers with gravel in between
d. Lawn Pavers
Q187 Given Government Office Building with a Beam with a span of about 8.50m-10.00 m. What is the ideal Column size at the 4th floor to support it? a.
0.80 x 0.80
b. 1.00 x 1.00 c.
1.20 x 1.20
d. 1.60 x 1.60
Q188 What should be the size of a Column at the Ground Floor if it has an 8m span? a.
0.50 m x 0.50 m
b. 0.70 m x 0.70 m c.
1.20 m x 1.20 m
d. 1.60 m x 1.60 m
Q189 What should be the size of a Column at the Fourth Floor if it has an 8m span? a.
0.50 m x 0.50 m
b. 0.70 m x 0.70 m c.
1.20 m x 1.20 m
d. 1.60 m x 1.60 m
Q190 What is the ideal room size, in square meters, for a Junior Executive Office with Side Return, 2 Client Chairs and a Filing Cabinet, and a Personal Computer? a.
2.20
b. 2.80 c.
3.20
d. 4.50
Q191 According to NBC, what is the maximum riser height and minimum run? a.
250 mm x 200 mm
b. 250 mm x 300 mm c.
200 mm x 250 mm
d. 200 mm x 300 mm
Q192 As per NBC what is the maximum door leaf width? a.
0.75
b. 0.90 c.
1.10
d. 1.20
Q193 Which flooring material is the LEAST resilient? a.
Vinyl Sheet
b. Linoleum c.
Ceramic Tiles
d. Vinyl Tiles
Q194 Given a ceiling area 4 m x 6.5 m, compute how many 0.60 x 1.20 pcs. acoustical ceiling board is needed? a.
35
b. 36 c.
37
d. 38
Q195 According to BP 344, what is the minimum width of toilet stall? a.
1.40 m
b. 1.50 m c.
1.80 m
d. 1.70 m
Q196 What is the ideal room size, in square meters, for a Junior Executive Office with 2 Client Chairs and a Filing Cabinet? a.
2.20
b. 2.80 c.
3.20
d. 4.50
Q197 Which color signifies purity and authority? a.
Yellow
b. Beige c.
White
d. Brown
Q198 On an ordinary site, where should the foundation rest? a.
Hard to very hard
b. Very soft to soft
c.
Medium to Hard
d. Soft to Medium hard
Q199 What is the Incremental Setback at the 10th floor at the front side facing the lot for a C-3 building on a C-3 lot fronting a 14-meter wide RROW?
a.
1.17
b. 3.51 c.
0.30
d. 0.00
Q200 Maximum height of fence wall without beam above grade? (Industrial) a.
2.00 m
b. 1.80 m c.
2.40 m
d. 3.00 m