Transmission Line, Transformer & Protection Laboratory
Transmission Line, Transormer & Protection Laboratory
Contents Re.no
Product
Page
MV 1431-1
Static Relay Trainer
4
MV 1434
Distance Protection Trainer
6
MV 1435
Dierential Relay Trainer
7
MV 1437
Frequency Relay Trainer
8
MV 1427
Relay Tester
9
MV 1918-1
Digital Timer
9
MV 1911
Transormer single-phase
10
MV 1915
Transormer 3-phase
11
MV 1972
Transormer 3-phase
11
MV 1919
Oil Immersed Transormer
12
MV 1931
Current Transormer
13
MV 1933
Current Transormer with Loads
13
MV 1934
Voltage Transormer with Loads
13
MV 1420
Line Model
14
MV 2221
Line Model
15
MV 2222
Line Model
15
MV 2225
Petersen Coil
15
MV 1424
Line Model
16
MV 1425
Line Model
17
MV 1438
Cabel Model
18
MV 1932-1
Universal Energy Meter
19
Loads
20
Rheostats
21
Power Distribution System
22
Laboratory Layout
23
Flexes
24
MV 1429
Terminal Board
25
MV 1104
Variable Transormer 1-ph
25
MV 1103
Variable Transormer 3-ph
25
MV 1300
Power Pack
25
MV 1305
Mobile Motor / Generator Unit
26
Terco reserves the right to make changes in the design and modifcations or improvements o the products at any time without incurring any obligations. 3
Transmission Line, Transormer & Protection Laboratory
Protective Relays MV 1431-1 Universal Relay Trainer The equipment is intended or practical training in static relay and relay protection engineering or applications i n power systems.
Following relays are provided: 1.
Microprocessor operated double over- and undervoltage relay
The Universal Relay Trainer MV 1431-1 is an integrated training system including dierent kinds o static relays, which are common in relay protection systems around the world.
2.
Microprocessor operated double over current relay
3.
Microprocessor operated multi-unction directional / reverse power relay
The static relays used in the experiment unit belong to the well known ABB COMBIFLEX relay system.
4.
Instantaneous over current relay
5.
Two types o auxiliary output relays
The Universal Relay Trainer MV 1431-1 does not only include static relays, it also contains a current transormer, a voltage transormer and an internal power supply. These components are all tted into a sturdy steel cabinet with a ront panel on which all sub units can be connected using either 4 mm saety sockets or 2 mm signal plug terminals. The choice o 2 mm signal plug terminals makes the unit compact and suitable or experiments with t he trainer standing on a table.
6.
Multirange time-lag relay
7.
Flag / signal relay, double unit
Built-in are also :
Mimic diagrams o the relays with large clear symbols are printed on the ront panel. Sockets are also provided or test objects.
•
Onecurrenttransformer
•
Onevoltagetransformer
•
Internalpowersupply
Supply voltage 220-240 V, 50-60 Hz, 1-ph
The rack carries a selection o the static relays used in modern electric power systems.
4
Dimensions
510 x 280 x 570 mm
Weight
30 kg
Transmission Line, Transormer & Protection Laboratory
Protective Relays The laboratory manual or the Universal Relay Trainer MV 1431-1 covers rom basic operation principles o each relay up to giving an introduction to the theory and the practical handling o typical situations where static relays are used to protect certain objects in or instance a power plant. The protected object may or example be a transormer, a generator, a bus bar or a eeder. The ocus o the proposed experiments is not only the dierent measuring relays, but the surrounding auxiliary relays are also described and used to build a relay protection.
8.
Operating the Reverse Power Relay Background and principle diagram The phase lag circuit Reverse power caused by low current Reverse power caused by low voltage Reverse power caused by the angle between the current and the voltage Reverse power setting Reverse power in unstable system
9.
From the basic operation principles, which can be understood by the experiments, the students obtain knowledge about how relay protection systems are built and how they will work in dierent situations.
Advanced Experiments Earth-ault protection (95%) Earth-ault protection using a current measuring relay Dierential protection Reverse Power / Loss o Synchronization protection
Experiment Manual
1.
Introduction
2.
Identiying the relays
3.
Auxiliary Equipment
Qty
Auxiliary relay
Basic and Medium Level
Recommended peripheral equipment or MV 1431-1:
Signal/fag relay
1 pc 1 pc 1 pc 1 pc 1 pc 2 pcs 2 pcs 1 set 3 pcs 1 pc
Current measuring relay, classic Current measuring relay, double Voltage measuring relay, double Power measuring relay Multiunction time relay Tripping relay 4.
Basic Experiments Operating the tripping relay Operating the signal relay
Description
Variable transormer Terminal board Load switch Digital timer Rheostat 200 W / 5 Ohm Rheostat 500 W / 2500 Ohm Dierential probe Flex set, saety plugs Digital multimeter Clip-on ammeter
Cat.Code
MV 1103 MV 1429 MV 1500 MV 1918-1 MV 1957 MV 1963 MV 1971 MV 1830-HF
Extended Level In addition to the equipment above
Operating the current relay Time delay o the tripping relay
1 pc 1 pc 1 pc 2 pcs 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc
Time delay o the current relay 5.
Modern Multiunctional Time Relay Time relay at DC-operation Time relay at AC-operation Time relay together with measuring current relay
6.
Double Overvoltage Relay Get amiliar with the relay Dene time over/under voltage unction
Rheostat 200 W / 5 Ohm Push button panel Contactor Current transormer Transormer, 1-phase Transormer, 3-phase Line model Load resistor 3-phase Digital multimeter Clip-on ammeter
MV 1957 MV 1400 MV 1402 MV 1931 MV 1911 MV 1915 MV 1420 MV 1100-235
Inverse time over voltage unction Advanced Level In addition to the levels above
The instantaneous over voltage unction The infuence o voltage transormers 7.
Double Over Current Relay
1 pc
Get amiliar with the relay Dene time over current unction Inverse time over current unction The instantaneous over current unction The infuence o current transormer
5
Mobile motor-generator unit
MV 1305-235
Transmission Line, Transormer & Protection Laboratory
Protective Relays MV 1434 Distance Protection Trainer This unit is intended or advanced training in static relay technology and relay protection engineering or applications on middle- and high voltage OH-transmission lines, cables and network sections in power systems.
• Settingsfortripfunctions • Howtosettheterminal • Creatingradiusnetworkandcalculatingtheimpedance map • Faultsonamediumvoltageline(MV1424) • Faultsonahighvoltageline(MV1425) • Faultsonacableline(MV1438)
The measuring technique used in the distance protection relay terminal is based on pure numerical methods. Versatile local man machine communication (MMC) rom the relay ront panel, together with a general purpose communication port, brings distance protection relay close to the user, whether he will be located in a substation, control centre or in the students laboratory oce.
Recommended external laboratory equipment
2 pcs 1 pc 1 pc 1 pc 1 pc 1 pc
Programming and readouts are perormed rom the MMC or rom a standard PC, close-by or remote.
Features The line distance protection terminal is based on an advanced version o the distance protection relay rom ABB and includes:
1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 2 pcs 1 set 1 pc 1 pc
• Fivedistanceprotectionzonesformultiphasefaults with individual setting o the directionality and reach in both reactive and resistive direction, mixed orward and reverse. • Separateandindependentimpedancemeasuring elements or the General Fault Criteria (GFC) with advanced characteristics. • Eventrecorder. • Disturbancerecorder. • Faultlocator. The trainer module contains, except or the protection relay, the ollowing unction modules: • • • • • •
InternalDC-powersupply Necessarycurrenttransformers Necessaryvoltagetransformers Breakersimulator Digitalinputspanel Outputpanelforcommunication,indications and tripping • AuxiliaryrelaysforACandDC • Software: DiscsorCDforinstallation User´s manual and technical specications Experiment manual Examples o topics described in Experiments Manual: • Electricaldiagramsandidentifyingcomponents • Conditionsfortripping • Introductiontoprogrammingandcalculationfor a distance relay • Calculatingimpedanceratio • Calculatingsecondaryimpedances • Settingparametersforimpedancezones • Settingoftimersforthedistanceprotectionzones • Selectingzonereach • SettinginstructionGFC(GeneralFaultCriteria) 6
Voltmeter 50-250-500 V A-meter 0-1-2 A A-meter 0-6-12 A 3-ph power supply 0-230 V Terminal board 1-ph load resistor 40 ohms, 2.25 A Line model OH line 40 kV Line model OH line 130 kV Cable model 5 kV 3-ph load resistor 230 V, 5 A Capacitor load bank Inductive load bank Load switch Laboratory leads Stand or lab. leads PC
MV 1926 MV 1922 MV 1923 MV 1103 MV 1429 MV 1966 MV 1424 MV 1425 MV 1438 MV 1100-235 MV 1102 MV 1101 MV 1500 MV 1830-HF MV 1904
Supply Voltage
220-240 V, 50-60 Hz, 1-ph
Dimensions Weight
510 x 280 x 570 mm 25 kg
Transmission Line, Transormer & Protection Laboratory
Protective Relays MV 1435 Dierential Relay Trainer Recommended external laboratory equipment
This unit is intended or practical training in static relay and relay protection engineering regarding dierential protections around transormers and busbars in power systems. The static relays used are ABB COMBIFLEX type. The dierential relay consists o the ollowing submodules: restraint- and dierential circuitry unit, lter and measuring unit, trip- and alarm unit, signal- and indication unit together with a test block to which an external relay tester can be connected. The trainer integrates the dierential relay blocks, 12 current transormers, a circuit breaker simulator, input terminals, output terminals, transormer connection panel and operating power supplies o 230 V AC and 110 V DC. Examples o experiments:
Electrical diagrams and identiying components Conditions or tripping Settings and indications o the dierential relay Characteristics o current transormers Primary and secondary CT-currents at symmetrical- and nonsymmetrical loads Protection o a single-phase transormer Protection o a three-phase transormer in Yy-connection Protection o a three-phase transormer in Yd-connection Busbar protection
7
1 pc 1 pc 2 pcs 1 pc 4 pcs 1 pc
Experiment transormer, 1-ph Experiment transormer, 3-ph Voltmeter 250 V A-meter 1A and 2A, or multimeters A-meter 6A and 12A, or multimeters Variable transormer 3-ph
1 pc 3 pcs 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 set 1 pc 1 pc 1 pc 1 pc
Terminal board Rheostat 0-5 ohm, 6.3A 3-ph load resistor 230 V, 5A Rheostat 0-50 ohm. 2.0A Pushbutton box or the breaker Switch Timer Capicator load bank Reactor load bank Laboratory leads Test handle Clip-on ammeter Ohmmeter (Multimeter) Oscilloscope
MV 1911 MV 1915 MV 1926 MV 1922 MV 1923 MV 1103 (or MV 1300) MV 1429 MV 1957 MV 1100-235 MV 1959 MV 1400 MV 1500 MV 1918-1 MV 1102 MV 1101 MV 1830-HF MV 1233
Supply Voltage
220-240 V, 50-60 Hz, 1-ph
Dimensions Weight
510 x 280 x 570 mm 32 kg
Transmission Line, Transormer & Protection Laboratory
Protective Relays MV 1437 Frequency Relay Trainer The trainer consists o industrial protection relays rom ABB which has been built into a suitable enclosure together with auxiliary relays, a contactor relay, external power supplies and a connection board with a mimic diagram.
Technical specifcations:
Mains supply Fuses Internal DC-supply DC-supply for electronics Frequency range over requency 1 Frequency range under requency 2 Rate o change o requency (d/dt) Trip relay or power circuits Contactor relay, three-phase or machine circuits
The integrated protection rom ABB is placed behind a glass door and each module in the integrated relay is covered by a plastic protection to protect rom dust when not used or experiments. The connections or experiments are to be connected by 4 mm saety plugs o the lab. fex cords but may also be connected by the earlier used contact type. The trainer can be used together with most types o laboratory equipment working on a voltage level o 220-400 V.
Dimensions Weight
220-240 V, 50-60 Hz glass tube 5 x 20 mm, 2 A F 230 V DC ± 24 V 50 ± 5 Hz 50 ± 10 Hz 0,5-10 mHz/sec 5 A/250 V 16 A/500 V
510 x 280 x 570 mm appr. 25 kg
Recommended external equipment: Setting possibilities:
• Settingrangefor±10Hzvariant – Stage 1 ( 1) or 45-55 Hz or 55-65 Hz – Stage 2 ( 2) or 40-60 Hz or 50-70 Hz Stage 2 can also be used or rate-o-change o requency (d/dt) • Combinesfrequency,rate-of-change(df/dt)andtime delay unctions in one module • Absolutevaluedf/dtornegativedf/dtonly • Measuringvoltagerange20-320VAC(inputvoltage transormer included) • Timedelaysettableupto20s.
Technical description o the protection:
The over/under requency relay is a static microprocessor based relay with two delayed stages. The relay consists mainly o an input voltage transormer, lter circuits, microprocessor, MMI, LEDs or start, trip indications and three output units which provide separate change-over contacts or start indication o stages 1 and 2, trip o stage 1 and trip o stage 2 Operate values or both stage 1 and 2, are set with the potentiometers and programming switches. Both measuring stages can independently be programmed or over- or under requency unctions. Operation occurs or a requency equal to or larger/lower than the set scale value and the selected scale constant.
8
1 pc
Mobile motor-generator unit
1 pc 1 set
Load resistor Flex set
MV 1305-405 (or MV 1305-235) MV 1100-235 MV 1830-H
Transmission Line, Transormer & Protection Laboratory
Protective Relays MV 1427 Relay Tester Range o application
Testing o current-, voltage-, time- and power-relays. Start-up operations where variable current and voltage are required. Testing o current transormers – ratio tests – plotting o magnetisation curves. In electrical and measuring departments or in laboratories and technical schools. Specifcations
AC current 0-10 A (85 V), 0-40 A (25 V), 0-100 A (10 V) Built-in ammeter, ranges 0-10 A, 0-100 A Terminal or an external ammeter AC voltage 0-250 V, 3 A DC voltage 0-350 V, 2 A 110 V AC, 0.3 A terminal 20-220 V DC, 0.3 A terminal (independently adjustable) Built-in capacitor or testing o reactive power relays Terminal or synchronous start o an external device Electronic timer, independent o mains requency. Measuring range 0-999.999 sec. Accuracy 0.02 % o readouts +2 ms. Terminal or external start and stop o timer The tripping circuit is equipped with a signal lamp Resistor set or voltage division etc. Thermal protection o the output transormer Mains supply
The Relay Tester can be delivered or 110, 220 or 240 V AC, 50-60 Hz. Please speciy one
Dimensions Weight
280 x 178 x 178 + 63 mm 15 kg
MV 1918-1 Digital Timer Suitable or measuring the pick-up and drop-out times o relays and or physical experiments. The timer has two inputs that can be wired either to start or stop timing. Timing is started or stopped by every change at the inputs (make or break). It is also possible to connect the timer to one o the inputs only, in which case the closing o a make contact starts the timer, and the opening o the circuit stops it. The inputs are protected or over-voltage, AC and DC. General Data
Two measuring ranges
Accuracy Resolution Height o digits Mains supply
Timer 1 msec - 60 sec Counter 1 - 65 000 counts 230 V DC max. ±0.1%ofreading±1digit 1 msec 7 mm 220-240 V, 50-60 Hz
Dimensions Weight
175 x 200 x 90 mm 1 kg 9
Transmission Line, Transormer & Protection Laboratory
Transformers Experiment Transormers These transormers are designed or studies o single and three-phase transormers, by the completion o a series o experiments, which are described in detail in the instruction manuals. These include: Eciency and short circuit impedance. Waveorm o the no-load current. Inrush current. Three-phase connections. Unbalanced loading. To complete all those experiments the ollowing peripheral equipment is required:
Qty
Description
Cat.Code
1 pc 1 pc 1 pc 1 pc 1 pc 2 pcs 3 pcs 4 pcs 3 pcs 4 pcs 1 pc 1 set
Variable 3-phase transormer Terminal board Load resistor Load reactor Load capacitor Voltmeter 0-500 V Ammeter 0-2 A Ammeter 0-12 A Wattmeter 1 A, 0-500 V Wattmeter 5 A, 0-500 V Load switch Laboratory leads, 4 lengths, 5 colours Floor stand or laboratory leads Multimeter Memory oscilloscope
MV 1103 MV 1429 MV 1100-235 MV 1101 MV 1102 MV 1926 MV 1922 MV 1923 MV 1927 MV 1928 MV 1500
1 pc 1 pc 1 pc
MV 1911 Transormer single-phase Ratings
Single-phase 1 kVA, 50-60 Hz Primary: 230 V ± 5 % Secondary: 4 x 57.5 V ± 5 %
The secondary winding is divided into our windings or series or parallel connection. No load losses Po = 25 W Impedancevoltageek=8% Resistancevoltage ek=3% MV 1911 can be used or determination o operating characteristics, losses and eciency o a single-phase transormer by means o no load, short-circuit and load tests. The transormer has saety sockets mounted on a rontpanel with mimic diagrams. Dimensions Weight
210 x 150 x 210 mm 22 kg
MV 1500 Load Switch Three-pole, 16 A, 250 V- DC / 440 V-AC, switch in metal case. Front panel showing symbols and technical data. Marking o terminals
input output
Dimensions Weight
95 x 200 x 80 mm 1 kg
R, S, T U, V, W
10
MV 1830-HF MV 1904
Transmission Line, Transormer & Protection Laboratory
Transformers MV 1915 Transormer 3-phase Ratings Primary Secondary
Three-phase, 2 kVA, 50-60 Hz, 230/2 x 66.5 V per phase 0-133-230V ±5%perphase Two 66.5 V windings per phase, each winding having tappings or 0-38.4-44-66.5 V (± 5 %)
The tappings are so arranged that 230 V (star or delta connection) and 133 V (star, delta or zig-zag connection) can be obtained or all standard connections. This transormer has saety sockets mounted on a rontpanel with mimic diagrams. No load losses Po = 35 W Impedancevoltageek=8% Resistancevoltage ek=3% With MV 1915, asymmetrical loading and parallel connection o three-phase transormers or dierent three-phase combinations on the primary and secondary side, can be studied. It can also be used or determination o operating characteristics, losses and eciency. Dimensions Weight
300 x 190 x 345 mm 33 kg
MV 1972 Transormer 3-phase This transormer has an E-type core and is suitable or setting up a variety o circuits or 3-phase transormers. MV 1972 has saety sockets mounted on a rontpanel with mimic diagrams. General Data
Power rating Primary voltage
Three-phase 2 kVA, 50-60 Hz 400 V ± 5 % or 230 V ± 5 % per phase 2x66.5V±5%perphase 2.5 kV 92 %
Secondaryvoltage Test voltage Eciency Percentage impedance voltage 4 % approx. Dimensions Weight
350 x 165 x 260 mm 30 kg
11
Transmission Line, Transormer & Protection Laboratory
Transformers MV 1919 Oil Immersed Transormer MV 1919 is designed and equipped as a normal, industrial transormer and suitable or practicing installation, commissioning, operation and maintenance.
Technical Data
Oil immersed 3-phase transormer Rated power 10 kVA Rated requency 50/60 Hz Rated voltage Primary voltage 400 V, terminals for ± 5% Secondary voltage 230/400 V Cooling designation ONAN Connection designation Dyn 11/Dzn 10 Impedance voltage 3.8 % No-load losses 120 W Load losses 320 W
A small size tank is included or compressed air. The tank is provided with a lling valve and a connection to test the Buchholz relay (gas detector). Necessary peripheral equipment Qty
Description
Cat.Code
1 pc 1 pc 3 pcs 3 pcs 3 pcs 1 pc 1 set 1 pc 1 set
Load switch 440 V, 16 A Terminal board Wattmeter 1-phase 1 A, 0-500 V Voltmeter 0-500 V Current transormer Variable three-phase transormer Lab leads, 4 lengths, 5 colours Floor stand or laboratory leads Spare parts or oil immersed transormer Multimeter LCR-meter
MV 1500 MV 1429 MV 1927 MV 1926 MV 1931 MV 1103 MV 1830 MV 1904 MV 7002
3 pcs 1 pc
Dimensions Weight
Standard accessories:
01. 02. 03. 04. 05. 06. 07. 08.
09. 10. 11. 12. 13.
Expansion vessel with oil level indicator, oil ller hole and test tap Drying unit with oil seal (Dehydrating breather) Gas detector relay with signalling and tripping contacts Signal thermometer with signalling and tripping contacts Porcelain bushings or 1 kV O-circuit tap changer with three positions Rating plate Control cubicle with terminal blocks, a protector (fashover protection with a non-linear resistor or connection to the transormer neutral point) and a voltage transormer, 400 /110 V 3 Drain tray and drain valve Earthing terminal Liting lugs Testing equipment (tank) or gas detector relay Open core current transormer, 200/1 A
Documentation
A comprehensive manual contains a description o the equipment, applied theory and instructions or a number o experiments. The exercises include tests stipulated in IEC recommendations.
12
700 x 460 x 1260 mm 220 kg
Transmission Line, Transormer & Protection Laboratory
Current and Voltage Transformers MV 1931 Current Transormer Primary 20-15-5 A/Sec. 1 A Saety sockets Accuracy class
1.0
Dimensions Weight
95 x 200 x 80 mm 6 kg
MV 1933 Current Transormer with load combinations Current Transormer with load combinations a. Load or the single-phase current transormer consisting o two isolated ohmic resistors. b. Fixed resistor: about 0.5 ohm, load capacity about 7 A c. Variable resistor: about 0 - 60 ohm, load capacity about 7 A d. The variable resistor is protected with a use. e. Scale: 0 - 100 % Dimensions Weight
410 x 245 x 175 mm 12 kg
MV 1934 Voltage Transormer with load combinations a. b. c.
Load or the single-phase voltage transormer consisting o two isolated ohmic resistors. Fixed resistor: about 220 ohm, load capacity 0.5 A (0.5 A use) Variable resistor: range rom 300 - 1930 ohm, load capacity 0.25 A (0.25 A use)
Dimensions Weight
410 x 245 x 175 mm 12 kg
13
Transmission Line, Transormer & Protection Laboratory
Transmission The ollowing studies can be made:
The network model can be used to complete a series o experiments with transmission lines. Those listed and described in detail in the instruction manual include:
1. Measurements o characteristic data, resistance, reactance and capacitance o a line. 2. As transmission line: Measurement o voltage drop and losses or dierent loads. 3. For two-phase and especially three-phase short-circuit measurements with two three-phase transormers, one at each end. 4. For single-phase and two-phase earth ault measurements.
Characteristic data o the line. Voltage drop on the lines. Short circuit tests. Earth ault.
MV 1420 Line Model The model corresponds to a power transmission line o a length 136 km, voltage 77 kV, amperage 100 A, power rating 13 MW. To complete all the experiments the ollowing peripheral equipment (or similar) is required to MV 1420. Qty
Description
Cat.Code
1 pc 1 pc 1 pc 1 pc 1 pc 3 pcs 3 pcs 3 pcs 3 pcs 1 pc 1 pc 1 pcs 1 set 1 pc
Variable transormer Terminal board Load resistor Load reactor Load capacitor Voltmeter 0-500 V Ammeter 0-2 A Ammeter 0-12 A Wattmeter 5 A, 0-500 V Load switch Power actor meter Three-phase transormer Laboratory leads Floor stand or lab. leads
MV 1103 MV 1429 MV 1100-235 MV 1107 MV 1102 MV 1926 MV 1922 MV 1923 MV 1928 MV 1500 MV 1929 MV 1915 MV 1830-HF MV 1904
General Data
Voltage Amperage Line resistance Line reactance
220-240 V, three-phase (corresponding to 77 kV) 5 A (corresponding to 100 A) 1.5 ohms 3.15 ohms
Line capacitance divided into capacitance to earth (4 µF) and mutual line capacitance between phases (8 µF). Earth impedance Fuses
0.8 ohm 5 A
Dimensions Weight
410 x 245 x 160 mm 10 kg
Many different line models are available in the Terco programme: MV 1420 Line Model 77 kV, experiment voltage 220-240 V 3-ph. MV 2221 Line Model 230 kV, experiment voltage 380-415 V 3-ph. MV 2222 Line Model 11 kV, experiment voltage 380-415 V 3-ph. MV 1424 Line Model 40 kV, experiment voltage 380-415 V 3-ph. MV 1425 Line Model 130 kV, experiment voltage 380-415 V 3-ph. MV 1438 Line Model 11 kV, experiment voltage 380-415 V 3-ph.
14
Transmission Line, Transormer & Protection Laboratory
MV 2221 Line Model Line Model 230 kV, 100 km, 400 V 3-phase Three-phase model o an overhead power transmission line 100 km long, voltage 230 kV and ability 110 MVA Model value 400 V : R + 2.20 ohm, L 25 mH, C + 4uF, Co 2.5 uF. The network model can be used to complete a series o experiments with transmission lines. Those listed and described in detail in the instruction manual include characteristic data o the li ne. Voltage drop on the lines. Short circuit. Earth ault. Dimensions Weight
410 x 245 x 160 mm 10 kg To complete all the experiment, the ollwing peripheral equipment (or similar) i s required or MV 2221 and MV 2222.
MV 2222 Line Model Line Model 11 kV, 5 km, 400 V 3-phase Three-phase model o an overhead power transmission line 5 km long, voltage 11 kV and ability 5 MVA Model value 400 V : R + 2.4 ohm, L 17 mH, C + 30 nF, Co 20 nF. The network model can be used to complete a series o experiments with transmission lines. Those listed and described in detail in the instruction manual include characteristic data o the li ne. Voltage drop on the lines. Short circuit. Earth ault. Dimensions Weight
410 x 245 x 160 mm 10 kg
Qty
Description
Cat. Code
1 pc 1 pc 1 pc 1 pc 1 pc 3 pcs 3 pcs 3 pc 3 pcs 1 pc 1 pc 1 pc 1 set 1 pc
Variable transormer Terminal board Load resistor Load reactor Load capacitor Voltmeter 0-500 V Ammeter 0-2 A Ammeter 0-12 A Wattmeter 5 A, 0-500 V Load switch Power actor meter Three-phase transormer Laboratory leads Floor stand or laboratory leads
MV 1103 MV 1429 MV 1100-235 MV 1107 MV 1102 MV 1926 MV 1922 MV 1923 MV 1928 MV 1500 MV 1976 MV 1915 MV 1830-HF MV 1904
MV 2225 Petersen Coil, Multi Terminal Unit A Petersen coil is used together with OH-lines in the range o distribution voltage to medium voltage (MV). The most common ault is line-to-earth where the current is limited by the phase voltage rom the two healthy leads divided by the capacitive impedance added by the arc resistance and the remaining zero sequence impedance. Since this current is mainly capacitive it could be balanced by an inductance between the neutral point o the transormer and ground. That is to say: when a line-to-earth ault occurs it will be extinguished automatically by the current in the Petersen coil and the re-closing device will connect power again in a raction o a second. NormallyaHV-linehasarmground.However,inthiscasewemayalsostudya230kVmodelbecauseoftutorialaspects. Each inductance coil has three steps to optimize the reactance value or each line o “11 kV”, “70 kV” and “230 kV”. The 3 coils have ollowing values L=0.63Hand+/-30%terminals(70kV) L=1.00Hand+/-30%terminals(230kV) L=100Hand+/-30%terminals(11kV) MV 2225 is to be used together with the Line Models MV 1420, MV 2221 and MV 2222. Dimensions Weight
410 x 245 x 160 mm 11 kg
15
Transmission Line, Transormer & Protection Laboratory
Transmission Line Models The ollowing Line Models and Cable Model are designed or realistic conditions, such as overvoltage, overcurrent, and a certain magnetic coupling between the wires. As linear behaviour or excess values is required, the line inductances must be represented by non-saturable induction coils. To withstand certain overvoltages, overdimensioning o wiring and capacitors is necessary. One o the overhead models is representing a high voltage line o 220 kV, and the other a eeder at medium level 40 kV. All models are constructed as π-links, the HV model and the cable model as a double π-link. Flexibility to simulate typical situations, such as compensating a long line at both ends and also in the middle, must also be available. Combination o the π-links make it possible to create other characteristic data, e.g. capacitors can be connected in ∆ instead o Y.
MV 1424 Line Model Real line parameters Nominal length Nominal voltage Nominal current Positive sequence reactance X+ Zero sequence reactance X0 Positive sequence resistance R+ Zero sequence resistance R0 Positive sequence capacitance C+ Zero sequence capitance Co
40 km 40 kV 350 A 15 ohm 23 ohm 8.4 ohm
16.0 ohm 400 nF 265 nF
Line Model specifcations
Represented length Nominal voltage Maximum voltage Nominal current Maximum current R1=4.7ohm R0=0.8ohm X1=2πω x 5.45 mH X0=2.62ohm C1=1.0µF C0=0.6µF Dimensions Weight
40 km 400 V 600 V 10 A 32 A (60 sec)
600 x 600 x 1720 mm 190 kg
Terco reserves the right to make changes in the design and modications or improvements o the products at any time without incurring any obligations
16
Transmission Line, Transormer & Protection Laboratory
Transmission MV 1425 Line Model Line Model specifcations
Real line parameters
Nominal length Data or one 50 km section: Nominal voltage Nominal current Positive sequence reactance X+ Zero sequense reactance X0 Positive sequence resistance R+ Zero sequence resistance R0 Positive sequence capacitance C+ Zero sequence capacitance C0
100 km (2 sections, each 50 km)
Represented length
220 kV 775 A
Data or one π-link Nominal voltage Maximum voltage Nominal current Maximum current (60 sec)
18 ohm 24 ohm 1.77 ohm 8.0 ohm 475 nF
100 km with two π-links, each corresponding to a 50 km section 400 V 600 V 10 A 32 A
R1=0.5ohm R0=0.8ohm X1=2πω x 3.77 mH X0=1.57ohm C1=8.9µF C0=0.6µF
315 nF
Dimensions Weight
17
600 x 600 x 1720 mm 220 kg
Transmission Line, Transormer & Protection Laboratory
Transmission MV 1438 Cable Model MV 1438 consists o two cable sections with a nose section cable area o 150 square mm and 240 square mm respectively.
Real line parameters
Line Model specs
PEX Cable 150 square mm Al
(one π-link)
Length
5 km
corr. 5 km
Nominal voltage
11 kV
400 V
Nominal current
260 A
6A
Transmission ability
5.0 MVA
2.4 kVA
Positive sequence capitance C+
0.45 µF
0.28 µF
Zero sequence capitance C0
0.45 µF
0.28 µF
Inductance
1.8 mH
2.84 mH
Resistance
1.1 ohm
1.8 ohm
Zero sequence reactance X0 (approx.)
2.3 ohm
3.7 ohm
Real line parameters
Line Model specs
PEX Cable 240 square mm Al
(one π-link)
Length
5 km
corr. 5 km
Nominal voltage
11 kV
400 V
Nominal current
340 A
6A
Transmission ability
6.5 MVA
2.4 kVA
Positive sequence capitance C+
0.55 µF
0.26 µF
Zero sequence capitance C0
0.55 µF
0.26 µF
Inductance
1.6 mH
3.30 mH
Resistance
0.7 ohm
1.5 ohm
Zero sequence reactance X0 (approx.)
2.1 ohm
4.3 ohm
Dimensions Weight
600 x 600 x 1720 mm 190 kg
18
Transmission Line, Transormer & Protection Laboratory
Three-phase Universal Energy Meter / Analyser
MV 1932-1 Three-phase Universal Energy Meter / Analyser This unit is a microprocessor controlled three-phase energy meter / analyser with three or our wire unbalanced load
All experiments ollow about the same set-up which consist o: 1. 2. 3. 4. 5. 6.
MV 1932-1 is an universal energy meter or measuring kWh, kVAr and Maximum Demand. The ollowing will be applied or all three instrument unctions.
General data :
1. Use a power supply which can give a 3-phase voltage and a corresponding current according to what is written on the ront o the instrument. 2. It is not necessary to keep a constant voltage exactly according to what is given as nominal voltage. I, or example, you use an instrument designed or 3 x 230 V, it is recommended to connect a supply voltage around this value like 200-250 V. 3. It is not necessary to keep a constant current exactly according to what is given as nominal current. I, or example, you use an instrument designed or 10 A, it is recommended to run a current around 1-6 A because o practical reasons regarding the load congurations.
A power supply The power meter Three loads – resistive, inductive and capacitive An ammeter or rather a clamp-on ammeter A voltmeter A timer or a wrist-watch with a timer unction.
Programming Main unctions Secondary read-outs
From the ront kWh, kVArh (cap/ind), Max demand cosj, W, VAr (cap/ind), voltages, values o power
Voltage input Current input Operation requency possible Number of scales Scale response Power supply
3 x 230 V and 3 x 400 V 10A nominal, 20 A max 50-60 Hz nominal, 20 – 800 Hz 3 x 4 digits 1.5 sec From test circuit
Dimensions Weight
410 x 245 x 175 mm 17 kg
Terco reserves the right to make changes in the design and modications or improvements o the products at any time without incurring any obligations
19
Transmission Line, Transormer & Protection Laboratory
Load Units MV 1100 Load Resistor Load resistor MV 1100 contains three ganged resistors with continuous spindle regulation. The resistors are connected to terminals or 3-ph, single-phase or DC-voltage. The current in the resistor is limited by tubular wire uses in each phase. The unit has handles and wheels or simple and quick movement and is enclosed in a perorated metal cabinet. A cooling an is placed in the bottom o the resistor.
MV 1100-235 Cooling an supply 230 V AC 50 - 60 Hz MV 1100-116 Cooling an supply 110 V AC 60 Hz General Data 3-phase 3.3 kW, continuously adjustable. Star connection 400 / 230 V 0.8-5 A Star connection 230 / 133 V 0.5-5 A Delta connection 400 / 230 V 2.4-8.7 A Delta connection 230 / 133 V 1.3-8.7 A DC parallel connection 220 V 2.3-15 A Overload capacity, brie duration, approx. 20 %. Dimensions Weight
630 x 250 x 890 mm 46 kg
MV 1101 Load Reactor Enclosed in a strong metal cabinet. The ront panel has mimic diagram, terminals, uses and electrical data. The unit can be used on 1- and 3-phase systems. 12 step regulation.
General Data 2.5 kVAr, 50-60 Hz
V 230 230 400 230 230 400
Connection
Hz
A
star delta star star delta star
50 50 50 60 60 60
0.2-2.2 0.6-6.6 0.4-3.8 0.2-1.9 0.5-5.6 0.3-3.3
Dimensions Weight
510 x 220 x 320 mm 40 kg
MV 1102 Load Capacitor Housed in a metal cabinet. Electrical data and symbols on the ront panel with terminals and uses. This unit can be used on 1- and 3-phase systems. 6 step regulation.
General Data 2.8 kVAr at 50 Hz, 3.3 kVAr at 60 Hz.
V 230 230 400 230 230 230 400 230 Dimensions Weight
Connection
Hz
A
star delta star III star delta star III
50 50 50 50 60 60 60 60
0.4-2.4 1.2-7.2 0.7-4.2 2.1-12.6 0.5-2.8 1.4-8.6 0.8-5.0 2.5-15
185 x 370 x 170 mm 7 kg
20
Transmission Line, Transormer & Protection Laboratory
MV 1107 Load Reactor The reactor is continuously variable within the range 0.5-3.0 kVAr. When the reactor is connected to a system with 230 V between lines, the setting range can be increased to 0.15-3.0 kVAr by using Y-connection. The required reactive power is set by means o a crank. For easier setting, the load reactor has a ten-turn scale with 100 scale divisions or each turn. Each winding is tted with a use.
General Data 3-phase 0.5-3.0 kVAr, 400 V Y, 230 V Y, 50-60 Hz
V 230 400 230 400
Connection
Hz
A
star / delta star star / delta star
50 50 60 60
0.4-7.8 0.7-4.5 0.3-7.6 0.6-3.7
Dimensions Weight
340 x 170 x 380 mm 30 kg
Rheostats
Rheostats 100-500 W Standard Types
Each rheostat is enclosed in a robust metal case. The back, bottom and top o the case are perorated to provide optimum cooling. 2 glass uses protect the resistor agains excessive current and incorrect connection. A scale with 100 scale divisions shows the resistance setting. A ront panel o yellow painted steel with black screen painted symbols simplies series and potentiometer connection. Constructional eatures
The insulation is o high class ceramic material. The resistance wire used is o highest quality with very good linearity. Large fat brush with a sliding contact o copper graphite with specially balanced mounting guarantees perect contact with negligible wear on the resistance. 21
Resistance Ohm
Max. current A
Order No.
Power W
MV 1953 MV 1954 MV 1955 MV 1956
100 100 100 100
1 10 100 1000
10.00 3.20 1.00 0.30
MV 1957 MV 1958 MV 1959 MV 1960 MV 1966
200 200 200 200 200
5 15 50 300 40
6.30 3.70 2.00 0.80 2.25
MV 1961 MV 1962 MV 1963 MV 1964 MV 1965
500 500 500 500 500
150 500 2500 5000 10000
1.80 1.00 0.45 0.30 0.20
Dimensions
140x130 x 145
215x195 x 230
Transmission Line, Transormer & Protection Laboratory
Power Distribution System increases Saety in School Laboratories Terco´s Power Distribution System consists o a distribution board which is installed near the classroom. Each circuit is protected by a MCB, making energising and isolating a simple process or the teacher. There is also a protection device which breaks the voltage in the event o accidental disturbance in any phase. An emergency stop is placed in a prominent position in the classroom and will break all supplies when operated. Other voltages available Voltage system in the lab: 400/230 V 3-ph and 230 V 1-ph on request. Incoming voltage 400/230 V 3-ph
TF 1251 Distribution Panel The distribution panel is manuactured in varnished sheet metal and used or separate distribution o power to each lab. group (student panel). It contains one main switch, eleven 3-pole 16 A MCB (miniature circuit breakers), one ELCB (earth leakage circuit breaker), oneindicatorlampandlockableON-key.Thedistributionpanel breaks the supply voltage when a current > 30 mA fows in the protection lead. TF 1251 is wired or connection o outgoing groups to each MCB. The incomming wires to be connected to the main switch. Dimensions 480 x 330 x 60 mm Weight 10 kg
TF 1252 Student Panel or table mounting Comprising: One 3-pole main switch 16 A One MCB (Micro Circuit Breaker) 10 A Three 2-pole, 2-way earthed wall sockets One 3-ph socket CEE One protective earth terminal Junction line or distribution o any AC or DC voltage Dimensions 600 x 120 x 75 mm Weight approx. 4 kg
TF 1253 Transormer 10 kVA intermittent The transormer is air cooled and enclosed in sheet metal or placement on the foor. Main voltage 3-ph 380-415 V +/-5% 50-60 Hz Connection D/Y-0 Secondary 3-ph 380-415 / 220-240 V 50-60 Hz Dimensions 420 x 250 x 420 mm Weight 85 kg
TF 1229 Contactor with Thermal Protection Enclosed in a plastic cover Current: 16-24 A For transormer TF 1226 and TF 1253 Dimensions 142 x 115 x 112 mm Weight 1 kg
TF 1211 Emergency Stop Dimensions excluding the sign: Weight
70 x 70 x 70 mm 0.2 kg
Emergency sign in English enclosed See also our brochure: Power Distribution System and Furniture for Laboratories
22
Transmission Line, Transormer & Protection Laboratory
Laboratory Layout The layout is most important when designing a unctional laboratory. It is o great importance that equipment and urniture are taken into account early in the planning stage. A standard solution or planning a laboratory or 16 students can be seen below. I the space o the laboratory has been determined already, the standard solution may not be applicable. Our engineers will be pleased to advise on any individual requirements. See also our brochures or Power Distribution System and Furniture or Laboratories.
➐
➐ ➏ ➎
➊
➌
➊
➌ ➐ ➍
➊
➌
➊
➌
➑ ➍
➋
➊ Three-phase benches or accessories such as protective relays, loads, power supplies, switches, fex stands with fexes. ➋ Line models, foor standing. ➌ Four benches or experiments on transormers or or theoretical ollow-up o the experiments. ➍ Cabinets or instruments, tools and accessories. ➎ Teacher desk. ➏ Roller table. ➐ Terco Saety Power Distribution System with key-operated central, transormer, student-panels and emergency stops. ➑ Oil immersed transormer. 23
Transmission Line, Transormer & Protection Laboratory
Flexes MV 1830 Flex Set Set o 100 Leads in 5 colours. Area 2.5 mm 2 25 cm 50 cm 100 cm Red 5 5 5 Yellow 5 5 5 Blue 5 5 5 Black 5 5 5 Yellow/green 5 5 5
200 cm 5 5 5 5 5
MV 1830 Flex set also exists with double quantities o fexes as code no MV 1801
Separate Flexes
Terco Flex The Terco Flex complies with the saety requirement that connection shall not be made sideways, as well as with all reasonable demands on a laboratory fex.
Area 2.5 mm2.Pleasenote,eachRef.No.referstoapack o 10 leads. 25 cm 50 cm 100 cm 200 cm Red MV 1802 MV 1807 MV 1812 MV 1817 Yellow MV 1803 MV 1808 MV 1813 MV 1818 Blue MV 1804 MV 1809 MV 1814 MV 1819 Black MV 1805 MV 1810 MV 1815 MV 1820 Yellow/green MV 1806 MV 1811 MV 1816 MV 1821
Moulded sot PVC covering or high reliability cable anchorage.
▲
▲
6
4
General Data
Standard colours Standard area Rated current
▲ ▲
blue, read, yellow, black, yellow/green 2.5 mm2 containing 650 wires o 0.07 mm diameter 25 A
21 ▲
50 ▲
▲ ▲
Laboratory Flexes with Saety Plugs Saety lead with 2 covered spring plugs o 4 mm diameter, with sti protection sockets covering the plugs, and 4 mm diameter axial bushings moulded with Polypropylen, xed to 1.5 mm2 copper thread, PVC isolated, outer diameter 4 mm. Colours black, red, blue, yellow, green/yellow. Rated current 16 A.
MV 1830-HF Flex Set Area 1.5 mm2 Set o 100 leads in 5 dierent colours, red, yellow, blue, black, yellow/green, and 4 dierent lengths, 25, 50, 100 and 200 cm, 5 o each. 25 cm 50 cm 100 cm 200 cm Red 5 5 5 5 Yellow 5 5 5 5 Blue 5 5 5 5 Black 5 5 5 5 Yellow/green 5 5 5 5
Separate Flexes
MV 1830-HF Flex set also exists with double quantities o fexes as code no MV 1801-HF
Area 1.5 mm2 Pleasenote,eachRef.No.referstoapackof10leads. 25 cm 50 cm 100 cm Red MV 1802-HF MV 1807-HF MV 1812-HF Yellow MV 1803-HF MV 1808-HF MV 1813-HF Blue MV 1804-HF MV 1809-HF MV 1814-HF Black MV 1805-HF MV 1810-HF MV 1815-HF Yellow/Green MV 1806-HF MV 1811-HF MV 1816-HF 24
200 cm MV 1817-HF MV 1818-HF MV 1819-HF MV 1820-HF MV 1821-HF
Transmission Line, Transormer & Protection Laboratory
Accessories MV 1429 Terminal Board The box has saety outlets or laboratory leads with 4 mm diameter plug pins. These outlets are connected to a 5 x 2.5 mm2 cable o 1.5 m length and cable connection or a diameter o 5.5 mm. The connection box is equipped with miniature circuit breakers or 20 A. Dimensions Weight
250 x 240 x 75 mm 2.0 kg
MV 1104 Variable Transformer 1-phase The annular core o this variable transormer is o high alloy transormer sheet with small losses. The contact point on the winding, which is wound or a constant current obtained throughout the entire range, is provided by a sliding carbon contact. Thermal overload protector. Switch with pilot lamp. Rubber pedestals at the bottom and rear or convenient placing in the most suitable position at any time. 4 mm saety outlets. Input Output-maximum Dimensions Weight
230 V 0-260 V, 8 A, 50-60 Hz 200 x 190 x 205 mm 9 kg
MV 1103 Variable Transformer 3-phase Supplied with a scale showing output voltage. Thermal overload protection or three output phases are placed on the ront panel. A common shat rotates all output voltage sliders in parallel. The unit is mobile on 4 wheels. Same technical data as MV 1104 above. Input Output Dimensions Weight
3 x 400 V, 8 A, 50-60 Hz 3 x 0-450 V, 8 A 280 x 290 x 560 mm 34 kg
MV 1103-415 Variable Transformer Input 3 x 415 V, 8 A (maximum values), 50-60 Hz Output 3 x 0-415 V, 8 A Same technical data as MV 1103 above.
MV 1300 Power Pack This power supply unit i s especially adapted or laboratory experiments on electric machines and power systems. It can be used where variable or xed AC or DC is required. All outputs are used by MCB´s and have load switches. The Power Pack has also Earth Leakages Circuit Breaker (ELCB).
General Data MV 1300-235 Supply voltage 220-240 / 127-140 V 50 / 60 Hz 3-ph. MV 1300-405 Supply voltage 380-400 / 220-230 V 50 / 60 Hz 3-ph. MV 1300-415 Supply voltage 415 / 240 V 50 / 60 Hz 3-ph.
Output voltage
Standard
DC xed DC variable AC xed AC variable Fixed AC
Dimensions Weight
660 x 435 x 790 mm 103 kg 25
220 V 3.5 A 0-220 V 16 A 230/133 V 10 A 3-ph 3 x 0-230 V 10 A 3-ph 230 V 10 A
Transmission Line, Transormer & Protection Laboratory
MV 1305 Mobile Motor / Generator Unit A standard laboratory or power transmission normally consists o one or two generators, which are connected to one or more transmission links which nally reach transormers, distribution units and loads. Energy transer, load shedding, static and dynamic stability at disturbances as well as sophisticated protection schemes can be studied under realistic forms.Nottoforgetcompensationpossibilities. Power- and current- paths in grid networks are complicated. The TERCO system will give understanding or this problem. The wide range fexibility will be given by the mobile generator station / synchronous alternator (compensator) MV 1305. Two sets o MV 1305 can operate as described or work in parallel. In this case mechanical and electrical parameters might be changed by using e.g. fywheel (MV 1010) and dierent electrical connections. This unit is also suitable to be used together with Terco´s Frequency Relay Trainer MV 1437
Technical Specifcation
MV 1305-405
MV 1305-235
Power Supply
Voltage Frequency Max current
380-415 V AC 3-ph 50-60 Hz 16 A
380-415 V AC 3-ph 50-60 Hz 16 A
Turbine/DC-machine
Armature volt Field volt Armature current Field current Power Speed
0-240 V DC 190 V DC 12 A 0.8 A 2.0 kW 0-1800 rpm
0-240 V DC 190 V DC 12 A 0.8 A 2.0 kW 0-1800 rpm
Armature volt Power Cos j Field volt Speed
0-240 / 415 V AC 1.2 kVA 0.8 0-230 V DC 0-1800 rpm
0-140 / 240 V AC 1.2 kVA 0.8 0-230 V DC 0-1800 rpm
Synchronous generator
Speed control/ Active power control Feedback systems
SCR-converter, electronic current limit setting, start- and stop ramps. Manual requency setting Automatic/Constant setting
Field current supply
Integrated
Voltage control/ Reactive power control
PWM min. ripple-converter, electronic current limit setting
Feedback systems
Manual voltage setting Automatic/Constant setting Separate voltage eedback
Instruments: DC-machine (Turbine simulator)
AC-machine
Armature voltage Armature current Indication lamp or eld voltage Speed control potentiometer (=frequency control) Control method selector Armature voltage Voltage selector switch Armature current Voltage control potentiometer Control method selector Field current ammeter 26
Synchronizing devices
Synchronizing instrument Double voltmeter Double requency meter Synchronizing switch
Dimensions Weight
1550 x 800 x 1200 mm 200 kg (approx.)
to Hof
to hof o ou sokhol, sw.
scan drive system sd 2000
TERCO AB • P.O. Box 5014 • S E-141 05 HUDDINGE – STOCKHOLM • SwEDEN Telephone: +46 8 506 855 00 • Telefax +46 8 506 855 01 • http://.terco.se • e-mail
[email protected]
e j l ä t r e d ö S , B A i r e k c y r T e j l ä t r e t s Ö / 0 0 5 . 3 / 7 0 . 7 0 0 2