FIBER OPTICS AND DATA COMMUNICATION solution for wireless cellular sites and network
www.rosenberger.com www.rosenbergerap.com
Rosenberger HQ, Bavaria, Germany
INTRODUCTION Rosenberger Hochfrequenztechnik GmbH&Co. was founded in Germany in 1958 and ranks among the leading manufacturers of high-speed interconnect solutions worldwide. To serve the continuous growth and demand of the global market, Rosenberger Asia Pacific Electronic Co., Ltd. was established in China in 1997. With its long tradition of excellence and providing creative solutions, Rosenberger Asia Pacific has excelled and earned an outstanding reputation in the Asia Pacific region. Rosenberger Asia Pacific provides products and solutions for Telecommunication, Automotive Electronics, Information Technology, Test & Measurement, Aviation, and Medical & Industries. A sales network covering the entire Asia Pacific region generates an annual turnover close to 300 million USD. Reliability and competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading companies in their respective industries.
2
A
B
C
D
E Rosenberger Asia Pacific: A: Beijing, China− Headquarters, R&D and Production B: GOA, India − R&D and Production C: Guangdong Dongguan, China − R&D and Production D: Haryana, India − R&D and Production
F
E: Jiangsu Kunshan, China − R&D and Production F: Shanghai Pudong, China − R&D and Production
Rosenberger Asia Pacific maintains 6 modern manufacturing and R&D base locations in Beijing, Shanghai, Kunshan and Dongguan in China as well as Haryana & GOA in India, the largest of its kind in the Asia Pacific Region. Rosenberger Asia Pacific is an ISO 9001 quality system, ISO 14001 environmental system, and ISO/TS 16949 automotive industry system certified company. Equipped with advanced machining, electronic plating, cable manufacturing, assembly and testing centers and staffed with more then 200 R&D engineers, Rosenberger Asia Pacific has developed the first class production assembly lines and exercises stringent product and quality control. Presently, Rosenberger Asia Pacific maintains a far reaching network of R&D, Production, Sales and Service which extends to the whole Asia Pacific and Middle East region. For over 55 years Rosenberger has established its brand and reputation all over the world. Moving forward, Rosenberger Asia Pacific will continue to provide excellent product solutions and services for its customers in the entire region.
.
3
MISSION STATEMENT • Design, manufacture and deploy total solutions for telecommunication networks worldwide • Create value for our customers through innovative products, customized services and cost effective solutions • Maintain the highest quality standards, state-of-the-art manufacturing facilities and employ reliable supply chain management to achieve and exceed customer expectations • Be socially responsible to our community and environment • Be committed to employee's personnel development
Core Value • Value Innovation • Customer Focus • Sustainable Growth • Social Responsibility
4
PRODUCT PORTFOLIOS
Base Station Antenna Feeder Systems Wireless Coverage Solutions Microwave Backhaul Solutions RF Connectivity Solutions
Telecommunication System Solutions
Passive Intermodulation Measurement Systems FTTA Fiber Optic Site Solutions FTTx-ODN Passive Network Solutions Fiber Optic Connectivity Solutions Low Frequency Cables and Components Network Optimization Services
Premise Network Cabling Products
IT/Data Communication
Data Center/Cloud Computing Solutions Intelligent Infrastructure Management System
RF Test Cables
Test and Measurement
RF Precision Connectors Calibration Kits Accessories and Tools
FAKRA Connectors and Cable Assemblies
Automotive Electronics
HSD® System HVR® High Voltage Connectors RoPD® Power Data Connectors
Non-Magnetic RF Connectors Non-Magnetic RF Cable Assemblies
Medical & Industries
Data/RF/Power/DC Hybrid Connectors and Assemblies Customized Data/Power Connectivity System Fiber Optic Connectivity Products
5
The Advanced Fiber Optics and Data Communication Solution for today and tomorrow’s wireless cellular sites and network Remote radio head (RRH) has become one of the most important subsystems of today and tomorrow's distributed wireless infrastructure. Remote radio head has operation and management processing capabilities and it has standardized or customized optical, power, data and RF interfaces for connecting to the rest of wireless radio network. The evolution and deployment of remote radio systems significantly improve the network bandwidth and performance while at the same time reduce energy consumption. The ubiquitous data explosion continues today in the every place and every second which demands the upgrades or new deployments of 3G and 4G-LTE network infrastructure by applying remote radio technology. Rosenberger is committed to develop and supply the most reliable fiber optic, power and data cabling infrastructures for fiberto-the-antenna (FTTA) and power-to-the-antenna (PTTA) as well as the communication network requirements.
The New Generation of FTTA Cabling This becomes effective in streamlining operations when replacing traditional base station equipment with RRHs or upgrading a site to support RRHs. There is a huge demand for highspeed data transfer in today’s global mobile telecommunication networks. Fiber-feeder remote radio technology offers potential savings in both capital expenditure (CAPEX) and operating expense (OPEX) reductions compared with traditional coaxial cable based solutions. The connectivity and cable performance between the base station and RRH/antenna is essential for maintaining the quality of service between the networks and end users. A single hybrid cable provides multiple fiber and copper transmission lines. This is a clear advantage as it consolidates space and provides room for growth for additional RRHs besides many other benefits. Rosenberger EasyLinkTM hybrid solution benefits telecommunication operators with innovative interconnect technology which can meet the next-generation mobile network requirements.
Telecommunication Office Interconnect Solution The network performance is also assured by having a more reliable, high bandwidth and low latency switching and transmission system. Software defined networking (SDN) and radio (SDR) equipment and new silicon photonics technology require high quality interconnect solutions particularly the fiber optic connectivity and cable assemblies, in addition to traditional copper solutions. Rosenberger is sophisticated in offering both copper and fiber optic interconnect products in all available bandwidths and interfaces, which are designed and manufactured for achieving the optimum performance mechanically, environmentally and in the way of transmission. The Rosenberger passive interconnect cable products are compatible to all communication equipment vendor products and supports the future upgradability of active equipment.
Leading Connectivity and Cable Products Not only Rosenberger supplies the industry-standard connectivity products both fiber optics and copper, but also the specialized 2-fiber Rosenberger Duplex Connector (RDC), 4-fiber Rosenberger Quad Connector (RQC), 12/24-fber Rosenberger Multi-fiber Connector (RMCTM) and Rosenberger Fiber Enclosure (RFE) the field installable IP67 waterproof kit have been developed for realizing today and tomorrow’s high density FTTA cabling, smart-grid and industrial cabling applications in harsh environment. Rosenberger Cable Systems designs and manufacturers standard and customized fiber optic cables according to the highest quality standards both IEC and Telecordia. UL and/or Anatel certified cable are able to be fulfilled together with monkey-bite design for certain local market requirements.
6
+
+ 1991-2014
+
+
+
+
+
+
+
+
+
7
7
Superior Quality The quality of our products and services is an essential part of our corporate strategy. Rosenberger’s quality philosophy is not just to optimize components and products, but to continuously improve and optimize all processes to ensure customer satisfaction: from product development, planning, purchasing, production, sales, logistics and service to environmental policy – all in all, to offer maximum benefit to our customers all over the world. Responsibility for quality also means being proactive in protecting our environment and natural resources. We endeavour to avoid or minimize environmental pollution – even beyond the requirements of legal regulations whenever possible. Rosenberger is certified according to ISO/TS 16949, ISO 9001 and ISO 14001
Environmental Directives Connectors and cable assemblies manufactured by Rosenberger correspond to the following Directives: • 2011/65/EU - Restriction of the use of certain Hazardous Substances in electrical and electronic equipment (RoHS) • 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) The objective of the above mentioned European Directives is to avoid or to limit the use of the following hazardous substances: • Lead • Mercury • Cadmium • Chrome VI • PBB (Polybrominated Biphenyls) • PBDE (Polybrominated Diphenyl Ethers)
8
Content Introduction................................................ 2 Discrete FTTA Solution............................ 10 FTTA Cable Assembly E Series........................................... 11
Copper Connectivity Solution.................. 53 D-Sub Series Cable Assembly............................................ 54 RJ45 Ethernet Cable Assembly........................................... 55 Customized Assembly......................................................... 58
FTTA Cable Assembly H Series.......................................... 13
Ethernet Patch Panel.......................................................... 60
FTTA Cable Assembly N Series.......................................... 15
Balun Panel......................................................................... 63
FTTA Cable Assembly S Series........................................... 17
LSA Module and Distribution Unit........................................ 66
Pre-terminated Trunk FTTA Solution....... 19
Power Cable Assembly........................... 69
RDC Trunk Solution............................................................. 20
Indoor D-sub Type High Power Cable Assembly................. 70
RQC Trunk Solution............................................................ 21
Indoor ET 2 Pole Power Cable Assembly............................ 71
LC Trunk Solution................................................................ 22
Outdoor IP67 Power Cable Assembly................................. 72 Outdoor IP65 Power Cable Assembly................................. 73
EasyLinkTM FTTA Hybrid Solution............ 23 EasyLinkTM RDC Hybrid Solution......................................... 24 EasyLink
TM
RDC Hybrid Trunk Cable.................................. 25
EasyLink
TM
Fiber Optic Connectivity.......................... 74 Rosenberger Multi-fiber Connector (RMCTM)....................... 75
RQC Hybrid Solution........................................ 27
Rosenberger Quad Connector (RQC)................................. 76
EasyLinkTM RQC Hybrid Trunk Cable.................................. 28
Rosenberger Duplex Connector (RDC)............................... 77
EasyLinkTM RMCTM Hybrid Solution..................................... 30
Rosenberger Effcient Connector (REC).............................. 78
EasyLinkTM RMCTM Hybrid Trunk Cable............................... 31
LC Loopback Connector...................................................... 79
EasyLinkTM LC Hybrid Solution............................................ 33
LC Connector...................................................................... 80
EasyLinkTM LC Hybrid Cable Assembly............................... 34
SC Connector...................................................................... 81 MU Connector..................................................................... 82
RRH Jumper............................................ 35 RDC Fiber Jumper.............................................................. 36 RQC Fiber Jumper ............................................................. 37
E2000TM Connector............................................................. 83 Rosenberger Fiber Enclosure (RFE)................................... 84
RMCTM Fiber Jumper........................................................... 38
Rosenberger Cable Systems.................. 85
Hybrid Jumper..................................................................... 39
Quality and Environment..................................................... 86
Distribution Box....................................... 41
Simplex Fiber Optic Cable................................................... 92
Buffered Fiber...................................................................... 90
Fiber Distribution Box.......................................................... 42 Power Distribution Box........................................................ 43 Hybrid Distribution Box........................................................ 44
Installation Accessory.............................. 45
Duplex Fiber Optic Cable.................................................... 94 Distribution Fiber Optic Cable............................................. 96 Breakout Fiber Optic Cable................................................. 98 Distribution Fiber Optic Cable for FTTA............................. 100 Armored Fiber Optic Cable for FTTA................................. 101 Breakout Fiber Optic Cable for FTTA................................ 102
Cable Clamp........................................................................ 46 Grounding Kits..................................................................... 47 Hoisting Grips...................................................................... 47
Fiber Optic Interconnect Products........... 48 Patchcord & Pigtail.............................................................. 49 Fiber Patch Panel................................................................ 51 High Density VelaTM Modular Fiber Patch Panel................. 52
9
Discrete FTTA Solution Rosenberger discrete FTTA solution supports all kinds of cellular radio site installation scenario whatever the remote radio heads (RRH) are collocated on top of tower or distributed on rooftop of a building. Rosenberger has developed and manufactured various fiber optic connectors such as RDC, RQC, RMCTM, RFE for harsh environment applications, fiber optic cables as well as cable assemblies with most stringent quality standards for remote radio network systems. Rosenberger has been the close partners of the major radio equipment manufacturers worldwide for many years by providing the world-leading Fiber-To-The-Antenna technologies and solutions.
10
FTTA Cable Assembly E Series
Description This FTTA cable assembly is designed for connecting the Main Unit (MU) and the E Series of Radio Remote Head (RRH).
Feature and Benefit • Good for all common 3G/4G-LTE radio systems • IP67 ruggedized and compact cable divider • IP67 classed RFE for RRH connection • 100% factory assembled and tested
• Plug-and-play installation • Armored cable for monkey-bite and anti-rodent protection • UL(OFNR) and Anatel certified cable available on request • Customized cable and cable assembly available on request
Specification Profile/Outline Type A Side B B A
B A
Side A
Type B Side A
Side B
Type C Side A Side B B A B A
Type D Side A
Side B B A
Type E
B
A
Side A Side B B A
11
Type F Side A
Side B
Type G Side A
Side B B A
Mechanical and Optical Property Type A
Type B
Type C
Type D
Type E
Type F
Type G
Connector Side A
LCD, SM
LCD (c/w RFE), LCD (c/w RFE), LCD (c/w RFE), SM SM SM
LCD, SM
LCD (c/w RFE), LCD (c/w RFE), SM SM
Side B
LCD, SM
LCD (c/w RFE), SM
LCD, SM
LCD (c/w RFE), SM
Fiber Optic Cable Fiber Type Fiber Count Cable Diameter Jacket Material Armor Protection
2 fibers 4.8mm
2 fibers 4.8mm
No
No
Min. Bending Radius (Static)
20mm
20mm
60mm
20mm
20mm
20mm
20mm
Min. Bending Radius (Dynamic)
30mm
30mm
100mm
30mm
30mm
30mm
30mm
Max. Tension Strength (Long-Term)
300N
300N
300N
300N
300N
300N
300N
Max. Tension Strength (Short-Term)
450N
450N
400N
450N
450N
450N
450N
3000N/10cm
3000N/10cm
Cursh Resistance Flame Resistance
LCD, SM
Single-mode according to ITU-T G.657A2, IEC 60793-2-10 4 fibers 2 fibers 2 fibers 2 fibers 5.0mm 4.8mm 4.8mm 4.8mm LSZH NO NO YES YES
2000N/10cm 3000N/10cm 7000N/10cm 7000N/10cm IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)
Smoke and Halogen Emission UV Resistance
LCD, SM
Yes
Temperature Range Operation Temperature Range Storage Temperature Range Installation 2011/65/EU(RoHS)
Yes
Yes
Yes
Yes
-40 °C to +80 °C -40 °C to +80 °C -20 °C to +60 °C Compliant
Packing and Delivery
12
2 fibers 4.8mm YES
7000N/10cm
IEC 60754-2, IEC 61034-2
Environmental Data
L ≤100 m L >100 m
LCD, SM
1 pc in a bag 1 pc on cardboard/wooden drum
Yes
Yes
FTTA Cable Assembly H Series
Description This FTTA cable assembly is designed for connecting the Main Unit (MU) and the H Series of Radio Remote Head (RRH).
Feature and Benefit: • Good for all common 3G/4G-LTE radio systems • IP67 ruggedized and compact cable divider • 100% factory assembled and tested • Plug-and-play installation
• Armored branch cable for anti-rodent protection and bird-proof • UL(OFNR) certified cable available on request • Customized cable and cable assembly available on request
Specification Profile/Outline
Type A Side A
Side B 1A
2A
1B
2B
Type B Side B
Side A 2A 1A 1B 2B
Type C Side A
Side B
1A 1B
0A
0A
0B
0B
1A 1B
13
Type D Side B Side A 0A 0B
1A 1B 1A
1B
Mechanical and Optical Property Type A
Type B
Type C
Type D
Connector Side A
LCD
LCD
2*LCD
2*LCD
Side B
LCD
2*FC
2*LCD
4*FC
Side A
Yes
Yes
Yes
Yes
Side B
Yes
No
Yes
No
Armored fan-out tube
Fiber Optic Cable Fiber Type
G652D, G657A2, OM2 or OM3 according to ITU-T standard
Fiber Count
2 fibers
2 fibers
Cable Diameter
7.0mm
7.0mm
Jacket Material Armor Protection Min. Bending Radius (Static) Min. Bending Radius (Dynamic) Max. Tension Strength (Long-Term) Max. Tension Strength (Short-Term) Crush Resistance
4 fibers
7.0mm
7.0mm
LSZH No
No
No
No
70mm
70mm
70mm
70mm
140mm
140mm
140mm
140mm
200N
200N
200N
200N
400N
400N
400N
400N
2200N/10cm
2200N/10cm
2200N/10cm
2200N/10cm
Flame Resistance Smoke and Halogen Emission UV Resistance
4 fibers
IEC 60332-1, IEC 60332-3-24, UL 1666 (optional) IEC 60754-2, IEC 61034-2 Yes
Yes
Yes
Environmental Data Temperature Range Operation
-40 °C to +80 °C
Temperature Range Storage
-40 °C to +80 °C
Temperature Range Installation
-20 °C to +60 °C
2011/65/EU(RoHS)
Compliant
Packing and Delivery
14
L ≤40 m
1 pc in a bag
L >40 m
1 pc on cardboard/wooden drum
Yes
FTTA Cable Assembly N Series
Description This FTTA cable assembly is designed for connecting the Main Unit (MU) and the N Series of Radio Remote Head (RRH).
Feature and Benefit • Good for all common 3G/4G-LTE radio systems • IP67 classed IP seal boot for RRH connection • 100% factory assembled and tested • Plug-and-play installation
• Standard or flexible (FLEX) connector boot • UL(OFNR) certified cable available on request • Customized cable and cable assembly available on request
Specification Profile/Outline Type A
Side B
Side A
Type B
Side A
Side B
Type C Side B
Side A B A
B
15
A
Type D B
A
A
Side B B
B
Side A A
B
A
Type E Side A
Side B
A
B
B
A
A
B
B
A
Mechanical and Optical Property Type A
Type B
Type C
Type D
Type E
Side A
LC SM(90°)
LC SM(Flex)
LCD SM(90°)
LCD SM(Flex)
LCD SM
Side B
LC SM(90°)
LC SM(Flex)
LCD SM
LCD SM(Flex)
LCD SM
Fiber Type
G652D/G657A
G657A2
G657A2
G657A2
G652D
Fiber Count
1 fiber
1 fiber
2 fibers
2 fibers
4 fibers
Cable Diameter
5.0mm
5.0mm
5.0mm
5.0mm
5.2mm
Jacket Material
PVC
PVC
PVC
PVC
LSZH
Connector
Fiber Optic Cable
No
No
No
No
No
Min. Bending Radius (Static)
Armor Protection
50mm
50mm
50mm
50mm
50mm
Min. Bending Radius (Dynamic) Max. Tension Strength (Long-Term) Max. Tension Strength (Short-Term)
75mm
75mm
75mm
75mm
75mm
600N
600N
600N
600N
600N
1200N
1200N
1200N
1200N
1200N
7500N/10cm
7500N/10cm
7500N/10cm
7500N/10cm
7500N/10cm
Cursh Resistance Flame Resistance
IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)
Smoke and Halogen Emission UV Resistance
IEC 60754-2, IEC 61034-2 (optional) Yes
Yes
Yes
Yes
Environmental Data Temperature Range Operation
-40 °C to +80 °C
Temperature Range Storage
-40 °C to +80 °C
Temperature Range Installation
-20 °C to +60 °C
2011/65/EU(RoHS)
Compliant
Packing and Delivery
16
L ≤100 m
1 pc in a bag
L >100 m
1 pc on cardboard drum
Yes
FTTA Cable Assembly S Series
Description This FTTA cable assembly is designed for connecting the Main Unit (MU) and the S Series of Radio Remote Head (RRH).
Feature and Benefit • Good for all common 3G/4G-LTE radio systems • IP67 ruggedized and compact cable divider • 100% factory assembled and tested • Armored cable for monkey-bite and anti-rodent protection
• Plug-and-play installation • UL(OFNR) certified cable available on request • Customized cable and cable assembly available on request
Specification Profile/Outline Type A
Grounding kit
Side B
Side A RX
RX
DU
RU
TX
Type B
TX
Grounding Kit
Side A A
Side B DU
TX
RX
Type C Side B A
Side A DU
TX
RX
17
Mechanical and Optical Property Type A
Type B
Type C
Side A
2*LC, SM
LCD(c/w PDLC03J-02) SM
LCD(c/w PDLC03J-01) SM
Side B
2*LC, SM
2*LC, SM
2*LC, SM
Fiber Type
G652D
G657B3
G657B3
Connector
Fiber Optic Cable Fiber Count
2 fibers
2 fibers
2 fibers
Cable Diameter
4.8mm
4.8mm
6.3mm
Jacket Material
LSZH
LSZH
LSZH
Yes
Yes
NO
Armor Protection Min. Bending Radius (Static)
50mm
50mm
60mm
Min. Bending Radius (Dynamic)
100mm
100mm
120mm
Max. Tension Strength (Long-Term)
300N
300N
600N
Max. Tension Strength (Short-Term)
450N
450N
1500N
7000N/10cm
7000N/10cm
3000N/10cm
Cursh Resistance Flame Resistance
IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)
Smoke and Halogen Emission UV Resistance
IEC 60754-2, IEC 61034-2 Yes
Yes
Environmental Data Temperature Range Operation
-40 °C to +80 °C
Temperature Range Storage
-40 °C to +80 °C
Temperature Range Installation
-20 °C to +60 °C
2011/65/EU(RoHS)
Compliant
Packing and Delivery
18
L ≤100 m
1 pc in a bag
L >100 m
1 pc on cardboard drum
Yes
Pre-terminated Trunk FTTA Solution The FTTA trunk solution utilizes one fiber cable trunk with 3 to 18 pairs / channels of optical fiber connecting base stations and remote radio heads (RRH) in wireless communication network, with or without a FTTA distribution box. One trunk can provide fiber for supporting up to 18 RRHs. Developing a fiber cable trunk system provides the fiber needed for today and future network growth requirements. All Rosenberger trunk fiber cables assemblies are 100% factory assembled and tested with performance guaranteed. Fiber optic jumpers with standard fiber optic LC connector interface are used in conjunction with Rosenberger FTTA trunk system.
19
RDC Trunk Solution
Description 2-fiber RDC (Rosenberger Duplex Connector) trunk is an innovative solution with multi-fibers in a single cable to simply the RRH deployments. The trunk is designed with slim dividers which split multi-fibers into individual outdoor cables. The trunk cables are terminated with IP67-rated RDC connectors. Different types of jumpers are available to allow connection between the trunk cable
and any vendor-specific hardware interface. Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • Up to 24 fibers • IP67 robust and compact divider • IP67 RDC connectors for water immersion and dust protection • Plug-and-play installation
• Reduced tower loading and leasing costs • Terminated with RDC in top breakout to connect with RRH by matching RDC fiber jumpers
Specification Profile/Outline 12 fibers RDC - LCD Length±Tolerance
Key B A
A
A-A
B
A
B
A
B
24 fibers RDC - LCD Length±Tolerance
Key B A
A
A-A
B
Trunk Cable Side A (Top) Side B (Bottom) Breakout Cable Length Cable Retention Force (Fiber Breakout) Cable Retention Force (Trunk Cable) Cable Bending Radius Min. (Installation) Cable Bending Radius Min. (Operation) Outer Diameter Nominal Jacket Material Fiber Type Flammability 2011/65/EU(RoHS) Temperature Range Packing
20
12 fibers 6*RDC
24 fibers 12*RDC
6*LC duplex
12*LC duplex 600mm, 700mm, 800mm 200N 1000N 10 times the cable diameter 20 times the cable diameter
6.2 ± 0.3mm
8.5 ± 0.5mm LSZH G657A, OM2, OM3 IEC 60332-1 Compliant -40°C ~ +70°C Wood board drum
RQC Trunk Solution
Description 4-fiber RQC (Rosenberger Quad Connector) trunk is an innovative solution with multi-fibers in a single cable to simply the RRH deployments. The trunk is designed with slim dividers which split multi-fibers into individual outdoor cables. The trunk cables are terminated with IP67-rated RQC connectors. Different types of jumpers are available to allow connection between the trunk cable
and any vendor-specific hardware interface. Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • Up to 24 fibers • IP67 robust and compact divider • IP67 RQC connectors for water immersion and dust protection • Plug-and-play installation
• Reduced tower loading and leasing costs • Terminated with RQC in top breakout to connect with RRU by matching RQC fiber jumpers
Specification Profile/Outline 12 fibers RQC - LCD Length±Tolerance
key
B A A
2B 2A 1B 1A
B
24 fibers RQC - LCD Length±Tolerance
key
B A A
2B 2A 1B 1A
B
Trunk cable Side A (Top) Side B (Bottom) Breakout Cable Length Cable Retention Force (Fiber Breakout) Cable Retention Force (Trunk Cable) Cable Bending Radius Min. (Installation) Cable Bending Radius Min. (Operation) Outer Diameter Nominal Jacket Material Fiber Type Flammability 2011/65/EU(RoHS) Temperature Range Packing
12 fibers 3*RQC 6*LC duplex
24 fibers 6*RQC 12*LC duplex 600mm, 700mm, 800mm 200N 1000N 10 times the cable diameter 20 times the cable diameter
6.2 ± 0.3mm
8.5 ± 0.5mm LSZH G657A, OM2, OM3 IEC 60332-1 Compliant -40°C ~ +70°C Wood board drum
21
LC Trunk Solution
Description Traditional trunk solution is a typical design using a LC connector terminated trunk cable and distribution box. The cable runs from the BBU up to a weatherproof distribution box at the tower top. The distribution box provides the interconnection point for fibers between the trunk cable and the jumpers leading to the RRHs.
Trunk Solution is the good choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • Up to 36 fibers • PRECONNECT® technologies • Loose tube cable with high tensile strength and crush resistance
• Fiber jumpers available to support vendor-specific interfaces • Connects to FO patch panel at base station side • Reduced tower loading and leasing costs
Specification Profile/Outline 12 fibers LCD - LCD
A
B A
B A
Length±Tolerance
B
A
B
A
B
24 fibers LCD - LCD
A
B A
B A
Length±Tolerance
B
Trunk cable 12 fibers
24 fibers
Side A (Top)
6*LC duplex
12*LC duplex
Side B (Bottom)
6*LC duplex
Breakout Cable Length Cable Retention Force (Fiber Breakout)
200N
Cable Retention Force (Trunk Cable)
1000N 10 times the cable diameter
Cable Bending Radius Min (Installation)
20 times the cable diameter
Cable Bending Radius Min (Operation) Outer Diameter Nominal Jacket Material Fiber Type Flammability
22
12*LC duplex 600mm, 700mm, 800mm
6.2 ± 0.3mm
8.5 ± 0.5mm LSZH G657A, OM2, OM3 IEC 60332-1
2011/65/EU(RoHS)
Compliant
Temperature Range Packing
-40°C ~ +85°C Wood board drum
EasyLinkTM FTTA Hybrid Solution The New Generation of FTTA Cabling−Hybrid Solutions are effective in streamlining operations when replacing traditional base station equipment with RRH or upgrading a site to support RRH. A single hybrid cable provides multiple fiber and power transmission lines. This is advantageous as it consolidates space and provides room for growth for additional RRHs. Rosenberger pre-terminated hybrid cable assemblies minimize the amount of cables running up the tower. A single hybrid cable provides several fibers and power conductors to support multiple RRHs. The flexible lightweight aluminum corrugated cable allows operators to ground the cabling system. To simplify installation, the Rosenberger hybrid cable outer dimension follows standard feeder dimensions (1/2", 7/8"or 1-1/4") and enables the use of standard feeder clamps and grounding kits.
23
EasyLinkTM RDC Hybrid Solution
Description EasyLink TM RDC (2-fiber Rosenberger Duplex Connector) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLinkTM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. The hybrid trunk cables are terminated with IP67rated RDC connectors. Different types of jumpers are available
to allow connection between the hybrid cable and any vendorspecific hardware interface. EasyLink TM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • Support up to 6 RRH • IP67 robust and compact divider • IP67 RDC and power connectors for water immersion and dust protection • Corrugated aluminum or copper tape armored design
24
• Plug-and-play installation • Reduced tower loading and leasing costs • Terminated with RDC on top breakout to connect with RRHs by matching RDC fiber jumpers • Easy adjustment of length of bottom breakout point
EasyLinkTM RDC Hybrid Trunk Cable Specification
Profile/Outline 3X3 (Top side 3 power connectors and 3 RDC)
Length±Tolerance
B A B A B A
3X6 (Top side 3 power connectors and 6 RDC)
B A B A
Length±Tolerance
B A B A B A B A
6x6 (Top side 6 power connectors and 6 RDC)
B A
Length±Tolerance
B A B A B A B A B A
25
Hybrid Trunk Number of RRH
3 RRH
Structure
6 RRH
3X3, 3X6 6X6 RDC (Rosenberger Duplex Connector) DC power Connector or open ended LC duplex open ended Aluminum Min. Ф63mm Min. Ф80mm 180mm 220mm 600mm, 700mm, 800mm 500mm 1500mm 1500mm 200N 500N 1000N 10 times the cable diameter 20 times the cable diameter -40°C ~ +70°C Wood board drum
Fiber Power Fiber Side B (Bottom) Power Material Divider Diameter Height Fiber Breakout Cable Length (Top)* Power Fiber Breakout Cable Length (Bottom)* Power Fiber Breakout Cable Retention Force (Divider) Power Breakout Hybrid Trunk Installation Cable Bending Radius Min. Operation Temperature Range Packing
Side A (Top)
Hybrid Cable Number of RRH Number of Copper Conductor Number of Fiber Conductor Size
3 RRH 6 (3 pairs) 6~12 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (6mm2) 27.5 ± 0.5mm (10mm2)
Outer Diameter Nominal Jacket Material Armored Type
6 RRH 12 (6 pairs) 12 (8AWG) 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (6mm2) 32± 0.8mm (10mm2)
FRPE, UV resistance Corrugated aluminum Copper tape Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 Uo/U 600/1000V IEC 60332-1, IEC 60754-2, IEC 61034-2 Compliant
Fiber Type Nominal Voltage Flammability 2011/65/EU(RoHS)
Ordering Information EasyLinkTM RDC Hybrid Series L98Y-C0001-XXX
Number of RRH
Number of fiber
3
6
Number of power conductor 6
L98Y-C0002-XXX
3
6
6
6
L98Y-C0003-XXX
3
6
6
10
3
12
6
4
3
12
6
6
L98Y-C0027-XXX
3
12
6
10
L98Y-C0103-XXX
6
12
12
4
L98Y-C0104-XXX
6
12
12
6
L98Y-C0105-XXX
6
12
12
10
L98Y-C0004-XXX
3
6
6
4
L98Y-C0005-XXX
3
6
6
6
L98Y-C0006-XXX
3
6
6
10
3
12
6
4
3
12
6
6
L98Y-C0030-XXX
3
12
6
10
L98Y-C0106-XXX
6
12
12
4
L98Y-C0107-XXX
6
12
12
6
L98Y-C0108-XXX
6
12
12
10
Fiber type
L98Y-C0025-XXX L98Y-C0026-XXX
G657A
L98Y-C0028-XXX L98Y-C0029-XXX
26
OM2
*XXX represents length (mm). E. g. L98Y-C0001-20000 means trunk length 20m
Power conductor(mm2) 4
EasyLinkTM RQC Hybrid Solution
Description EasyLinkTM RQC ( 4-fiber Rosenberger Quad Connector ) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLinkTM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. The hybrid trunk cables are terminated with IP67-rated RQC connectors. Different types of jumpers are available to allow
connection between the hybrid cable and any vendor-specific hardware interface. EasyLinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • • • • • • • •
Support up to 9 RRH IP67 robust and compact divider IP67 RQC and power connectors for water immersion and dust protection Corrugated aluminum or copper tape armored design Plug-and-play installation Reduced tower loading and leasing costs Terminated with RQC on top breakout to connect with RRH by matching RQC fiber jumpers Easy adjustment of length of bottom breakout point
27
EasyLinkTM RQC Hybrid Trunk Cable
Specification Profile/Outline 3X6 (Top side 3 power connectors and 3 RQC)
Length±Tolerance B A B A B A B A B A B A
B A
6X12 (Top side 6 power connectors and 6 RQC)
B A B A B A B A B A B A
Length±Tolerance
B A B A B A B A B A
9X18 (Top side 9 power connectors and 9 RQC)
Length±Tolerance
28
Hybrid Trunk 3 RRH
Number of RRH
Structure
6 RRH
9 RRH
3X6
Side A (Top) Side B (Bottom) Divider Breakout Cable Length (Top)* Breakout Cable Length (Bottom)* Cable Retention Force (Divider) Cable Bending Radius Min.
6X12 9X18 RQC (Rosenberger Quad Connector) DC power Connector or open ended LC duplex MTP open ended Aluminum Min. Ф63mm Min. Ф80mm Min. Ф80mm 180mm 220mm 220mm 600mm, 700mm, 800mm 500mm 1500mm 1500mm 200N 500N 1000N 10 times the cable diameter 20 times the cable diameter -40°C ~ +70°C Wood board drum
Fiber Power Fiber Power Material Diameter Height Fiber Power Fiber Power Fiber Breakout Power Breakout Hybrid Trunk Installation Operation
Temperature Range Packing *customized lengths available
Hybrid Cable 3 RRH 6 (3 pairs) 12
6 RRH 9 RRH 12 (6 pairs) 18 (9 pairs) 24 36 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG) 27.5 ± 0.5mm (4mm2) 32± 0.8mm (4mm2) 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (6mm2) 27.5 ± 0.5mm (6mm2) 32± 0.8mm (6mm2) 2 2 27.5 ± 0.5mm (10mm ) 32± 0.8mm (10mm ) 36± 0.8mm (10mm2) FRPE, UV resistance Corrugated aluminum Copper tape Copper tape Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG) Uo/U 600/1000V IEC 60332-1, IEC 60754-2, IEC 61034-2 Compliant
Number of RRU Number of Copper Conductor Number of Fiber Conductor Size Outer Diameter Nominal Jacket Material Armored Type Fiber Type Conductor Size Nominal Voltage Flammability 2011/65/EU(RoHS)
Ordering Information EasyLinkTM RQC Hybrid Series L98Y-C0109-XXX L98Y-C0110-XXX L98Y-C0111-XXX L98Y-C0115-XXX L98Y-C0116-XXX L98Y-C0117-XXX L98Y-C0121-XXX L98Y-C0122-XXX L98Y-C0123-XXX L98Y-C0112-XXX L98Y-C0113-XXX L98Y-C0114-XXX L98Y-C0118-XXX L98Y-C0119-XXX L98Y-C0120-XXX L98Y-C0124-XXX L98Y-C0125-XXX L98Y-C0126-XXX
Fiber type
G657A
OM2
Number of RRH
Number of fiber
3 3 3 6 6 6 9 9 9 3 3 3 6 6 6 9 9 9
12 12 12 24 24 24 36 36 36 12 12 12 24 24 24 36 36 36
*XXX represents length (mm). E.g. L98Y-C0109-20000 means trunk length 20m
Number of power conductor 6 6 6 12 12 12 36 36 36 6 6 6 12 12 12 36 36 36
Power conductor(mm2) 4 6 10 4 6 10 4 6 10 4 6 10 4 6 10 4 6 10
29
EasyLinkTM RMCTM Hybrid Solution
Description EasyLinkTM RMCTM (Rosenberger Multi-fiber Connector) terminated hybrid cable is an innovative solution to combine optical fibers and DC power lines in a single cable to simply the RRH deployments. The EasyLink TM hybrid system is designed with slim dividers which split multi-fiber and DC cables into individual outdoor cables. RMCTM adopt standard MPO fiber interface with additional protection to work under harsh environments which particularly applicable for 6 RRH and 9 RRH solution. The hybrid trunk cables
are terminated with IP67-rated RMCTM connectors. Different types of jumpers are available to allow connection between the hybrid cable and any vendor-specific hardware interface. EasyLinkTM Hybrid Solution is the best choice for operators who lease space on tower cell sites. It reduces annual leasing costs by reducing the space utilized on the tower. Plug-and-Play connections minimize installation time and require no tools.
Feature and Benefit • • • • • • • • •
30
Support 6 RRH and 9 RRH IP67 robust and compact divider IP67 RMCTM and power connectors for water immersion and dust protection 8 fibers and 12 fibers RMCTM as option Corrugated aluminum or copper tape armored design Plug-and-play installation Reduced tower loading and leasing costs Terminated with RMCTM in top breakout to connect with RRH by matching RMCTM fiber jumpers Easy adjustment of length of bottom breakout point
EasyLinkTM RMCTM Hybrid Trunk Cable
Specification Profile/Outline 6X12 ( Top side 6 power connectors and 3 RMCTM )
Length±Tolerance
9X18 ( Top side 9 power connectors and 3 RMCTM ) B A B A B A B A B A B A B A
Length±Tolerance
B A B A B A B A B A
31
Hybrid Trunk Number of RRU
6 RRH
Structure
6X12
9X18
RMCTM 8 fibers
RMCTM 12 fibers
Fiber
Side A (Top)
Power
DC power Connector or open ended
Fiber
Side B (Bottom)
9 RRH
LCD
MTP 12 fibers
Power
Open ended
Material Divider
Aluminium
Diameter
Min. Ф63mm
Min. Ф80mm
180mm
220mm
Height Breakout Cable Length (Top)* Breakout Cable Length (Bottom)*
Fiber
600mm, 700mm, 800mm
Power
500mm
Fiber
1500mm
Power
1500mm
Fiber Breakout Cable Retention Force (Divider)
Cable Bending Radius Min.
200N
Power Breakout
500N
Hybrid Trunk
1000N
Installation
10 times the cable diameter
Operation
20 times the cable diameter -40°C ~ +70°C
Temperature Range
Wood board drum
Packing *customized lengths available
Hybrid Cable Number of RRU Number of Copper Conductor Number of Fiber Conductor Size
6 RRH 9 RRH 6 (3 pairs) 18 ( 9 pairs) 24 36 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG) 32± 0.8mm ( 4mm2) 27.5 ± 0.5mm (4mm2) 2 27.5 ± 0.5mm (6mm ) 32± 0.8mm ( 6mm2) 32± 0.8mm (10mm2) 36± 0.8mm (10mm2) FRPE, UV resistance Copper tape Copper tape Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 Uo/U 600/1000V IEC 60332-1, IEC 60754-2, IEC 61034-2 Compliant
Outer Diameter Nominal Jacket Material Armored Type Fiber Type Nominal Voltage Flammability 2011/65/EU(RoHS)
Ordering Information RMCTM Hybrid Series Fiber type
Number of RRH
Number of fiber
Number of power conductor
Power conductor(mm2)
L98Y-C0127-XXX
6
24
12
4
L98Y-C0128-XXX
6
24
12
6
6
24
12
10
9
36
36
4
L98Y-C0134-XXX
9
36
36
6
L98Y-C0135-XXX
9
36
36
10
L98Y-C0130-XXX
6
24
12
4
L98Y-C0131-XXX
6
24
12
6
6
24
12
10
9
36
36
4
L98Y-C0137-XXX
9
36
36
6
L98Y-C0138-XXX
9
36
36
10
L98Y-C0129-XXX L98Y-C0133-XXX
L98Y-C0132-XXX L98Y-C0136-XXX
G657A
OM2
*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m
32
EasyLinkTM LC Hybrid Solution
Description Traditional Hybrid Solution is a typical design using a LC connector terminated hybrid cable and distribution box. The cable runs from the BBU up to a weatherproof distribution box at the tower top. The distribution box provides the interconnection point for power and fiber between the hybrid cable and the jumpers leading to the RRH. The Distribution box can include over-voltage protection
(OVP). A secondary distribution box at the bottom is optional. Towers containing multiple sectors can be supported by multiple LC terminated hybrid trunks. For example, 12 RRHs can be supported with only three LC terminated trunk cables running up to the tower.
Feature and Benefit • • • • • • • •
Support up to 6 RRH per distribution box Support up to 4 RRH per hybrid cable Hybrid tail jumpers instead of individual fiber and power jumpers to support vendor- specific interface Flexibility to replace or upgrade RRH by changing hybrid tail jumpers IP67 Hybrid distribution box for fiber and power Easily grounded within the distribution box Easy adjustment of length of breakout point in hybrid cable Connects to FO patch panel at base station side
33
EasyLinkTM LC Hybrid Trunk Cable
Specification Hybrid Trunk Side A (Top) Side B (Bottom) Breakout Cable Length (Top)* Breakout Cable Length (Bottom)* Cable Bending Radius Min.
Fiber
LC duplex
Power
Open ended
Fiber
LC duplex
Power
Open ended
Fiber
600mm, 700mm, 800mm
Power
500mm
Fiber
4m
Power
4m
Installation
10 times the cable diameter
Operation
20 times the cable diameter
Temperature Range
-40°C ~ +70°C
Packing
Wood board drum *customized lengths available
Trunk Cable Number of RRH Number of Copper Conductor Number of Fiber Conductor Size
4 RRH 8 (4 pairs) Up to 16 4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG) 27.5 ± 0.5mm (4mm2) 27.5 ± 0.5mm (6mm2) 27.5 ± 0.5mm (10mm2) FRPE, UV resistance Corrugated aluminum Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 Uo/U 600/1000V IEC 60332-1, IEC 60754-2, IEC 61034-2 Compliant
Outer Diameter Nominal Jacket Material Armored Type Fiber Type Nominal Voltage Flammability 2011/65/EU(RoHS)
Ordering Information LC Hybrid Series L98Y-C0081-XXX L98Y-C0082-XXX L98Y-C0083-XXX L98Y-C0084-XXX L98Y-C0085-XXX L98Y-C0086-XXX
Fiber type G657A
OM2
Number of RRH
Number of fiber
4 4 4 4 4 4
12 12 12 12 12 12
*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m
34
Number of power conductor 6 6 6 6 6 6
Power conductor (mm2) 4 6 10 4 6 10
RRH Jumper Rosenberger provides standard and customized RRH jumpers for connection between Rosenberger FTTA trunk cable assemblies or Rosenberger FTTA hybrid cable assemblies and remote radio heads (RRHs). RRH jumper provides installation and upgrade flexibility for different cellular site scenarios. Fiber optic jumper, power jumper as well as hybrid jumper are available from Rosenberger with 100% factory assembled and tested, and are compatible with all types of system vendor equipment interfaces. Particularly the Rosenberger RDC, RQC and RMCTM terminated fiber jumpers provide IP67-rated direct connection without extra distribution box required, which significantly ease the installation and reduce labor costs.
35
RDC Fiber Jumper
Description The RDC (2-fiber Rosenberger Duplex Connector) fiber jumper can directly connect RRHs and EasyLinkTM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with
RDC connector, these jumpers provide convenient and quick interconnection between the trunk cable and RRH or other equipment.
Feature and Benefit • Plug-and-play installation and convenient maintenance • IP67 outdoor waterproof 2- fiber connector • Flexibility to replace or upgrade RRH by changing RDC jumpers
Specification Profile/Outline Side B
Side A
Side B Side A
Side B
B A
Side A
B
A
For Nokia RRH
For Ericsson RRH
0.5dB 0.3dB 50dB 50dB 4.8mm Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 50mm 30mm 450N 300N 3KN/100mm -40°C ~ +80°C -40°C ~ +80°C -20°C ~ +65°C Compliant
RDC LC RDC LC
Insertion Loss Max. Return Loss Min. (Singlemode) Cable Diameter* Fiber Type
Installation Operation Installation Operation
Cable Bending Radius Min. Cable Tensile Strength Max. Cable Crush Resistance
Operation Storage Installation
Temperature Range
For Huawei RRH
2011/65/EU (RoHS) * Other cable size options are available upon request.
Ordering Information RDC Jumper Series L98B-893-XXX L98B-894-XXX L98B-895-XXX L98C-853-XXX L98C-854-XXX L98C-855-XXX
Fiber Type G657A
OM2
Number of Fiber 2 2 2 2 2 2
Top Connector LCD with RFE LCD LCD with IP seal LCD with RFE LCD LCD with IP seal
Bottom Connector RDC RDC RDC RDC RDC RDC
*XXX represent length (mm) from end to end. E.g. L98B-893-XXX means jumper length 5m.
36
Ericsson Huawei Nokia Ericsson Huawei Nokia
RQC Fiber Jumper
Description The RQC (4-fiber Rosenberger Quad Connector) fiber jumper can divectly connect RRHs and EasyLinkTM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with
RQC connector, these jumpers provide convenient and quick interconnections between the trunk cable and RRH or other equipment.
Feature and Benefit • Plug-and-play installation and convenient maintenance • High density 4-fiber Jumper • IP67 outdoor waterproof fiber 4-fiber connector
• Flexibility to replace or upgrade RRHs by changing RQC jumpers
Specification Profile/Outline Side A
Side A
Side B
Side B
Side B
A
B
A
B
B A
B A
Side A
For Nokia RRH
For Ericsson RRH
0.5dB 0.3dB 50dB 50dB Singlemode: G652D, G657A Mulitmode: OM1, OM2, OM3, OM4 4.8mm 50mm 30mm 450N 300N 1KN/100mm -40°C ~ +80°C -40°C ~ +80°C -20°C ~ +65°C Compliant
RQC LC RQC LC
Insertion Loss Max. Return Loss Min. (Singlemode) Fiber Type Cable Diameter*
Installation Operation Installation Operation
Cable ending Radius Min. Cable Tensile Strength Max. Cable Crush Resistance
Operation Storage Installation
Temperature Range
For Huawei RRH
2002/95/EC (RoHS) * Other cable size options are available upon request.
Ordering Information: RQC Jumper Series L98B-896-XXX L98B-897-XXX L98B-898-XXX L98C-856-XXX L98C-857-XXX L98C-858-XXX
Fiber Type G657A
OM2
Number Of Fiber 4 4 4 4 4 4
Top Connector LCD with RFE LCD LCD with IP seal LCD with RFE LCD LCD with IP seal
Bottom Connector RQC RQC RQC RQC RQC RQC
Ericsson Huawei Nokia Ericsson Huawei Nokia
*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.
37
RMCTM Fiber Jumper
Description The RMC TM (Rosenberger Multi-fiber Connector) fiber jumper can directly connect RRHs and EasyLink TM hybrid trunk cable assembly or FTTA trunk cable assembly. Terminated with
RMCTM connector, these jumpers provide convenient and quick interconnections between the trunk cable and RRH or other equipment.
Feature and Benefit • • • •
Plug-and-play installation and convenient maintenance High density up to 12/24 fiber IP67 outdoor waterproof fiber multi-fiber connector Flexibility to replace or upgrade RRHs by changing RMCTM jumpers
Specification RMCTM LC RMCTM LC
Insertion Loss Max. Return Loss Min. (Singlemode)
0.5dB 0.3dB 50dB 50dB G657A OM2 6.0mm 50mm 30mm 450N 300N 3KN/100mm -40°C ~ +80°C -40°C ~ +80°C -20°C ~ +65°C Compliant
Fiber Type Cable Diameter* Installation Operation Installation Operation
Cable ending Radius Min. Cable Tensile Strength Max. Cable Crush Resistance
Operation Storage Installation
Temperature Range 2011/65/EU (RoHS)
* Other cable size options are available upon request.
Ordering Information RMCTM Jumper Series L98B-899-XXX L98B-900-XXX L98B-901-XXX L98C-859-XXX L98C-860-XXX L98C-861-XXX L98B-902-XXX L98B-903-XXX L98B-904-XXX L98C-862-XXX L98C-863-XXX L98C-864-XXX
Fiber Type G657A
OM2
G657A
OM2
Number Of Fiber 8 8 8 8 8 8 12 12 12 12 12 12
Top connector LCD with RFE LCD LCD with IP seal LCD with RFE LCD LCD with IP seal LCD with RFE LCD LCD with IP seal LCD with RFE LCD LCD with IP seal
Bottom Connector RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM RMCTM
*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.
38
Ericsson Huawei Nokia Ericsson Huawei Nokia Ericsson Huawei Nokia Ericsson Huawei Nokia
Hybrid Jumper
Description The hybrid jumper can be used to connect RRH and EasyLinkTM hybrid cable assembly with a hybrid distribution box on top of tower. One end of jumper is usually terminated with LC connector or other equipment vendor-specific interface, and the other
end is terminated with standard LC connector. Power line ends are opened but possibly be terminated with customer-specific connectors upon request.
Feature and Benefit • Corrugated hybrid cable • IP67 waterproof protection at RRH side • Standard or customized length • Flexibility to replace or upgrade RRH by changing hybrid jumpers
Specification Profile/Outline Side A
Side B Side A
Side B Side A
Side B B A
B A
B A
B A
B A
A
B
A
B
B A
For Nokia RRH
For Ericsson RRH
For Huawei RRH
Specification Fiber
LC duplex or vendor-specific interfaces
Power
Open ended
Fiber
LC duplex
Power
Open ended
Fiber
0.75m
Power
0.75m
Fiber
0.5m
Power
0.5m
Insertion Loss Max.
LC
0.3dB
Return Loss Min. (Singlemode)
LC
50dB
Installation
50mm
Operation
30mm
Installation
450N
Operation
300N
Side A(Top) Side B(Bottom) Breakout Cable Length*(Top) Breakout Cable Length*(Bottom)
Cable Bending Radius Min. Cable Tensile Strength Max. Cable Crush Resistance
1KN/100mm
39
Temperature Range
Operation
-40°C ~ +80°C
Storage
-40°C ~ +80°C
Installation
-20°C ~ +65°C
2011/65/EU(RoHS)
Compliant
* Other cable length options are available upon request.
Hybrid Cable Number of RRH
1 RRH
Number of Fiber
2 to 4
Number of Conductor
2 (1 pair)
Outer Diameter Nominal
15.8 ± 0.5mm (1/2" cross-section)
Conductor Size
4mm2 (12AWG), 6mm2 (10AWG)
Jacket Material
LSZH, UV resistance
Armored Type
Corrugated aluminum Singlemode: G652D, G657A
Fiber Type
Multimode: OM1, OM2, OM3, OM4
Nominal Voltage
Uo/U 600/1000V
Flammability
IEC 60332-1
2011/65/EU(RoHS)
Compliant
Ordering Information Hybrid Jumper Series
Fiber Type
L98Y-718-XXX L98Y-717-XXX
G657A
L98Y-716-XXX L98Y-727-XXX L98Y-726-XXX L98Y-725-XXX
OM2
Number Of Fiber
Conductor
Top Connector
Bottom Connector
4
6mm2
LCD with RFE
LCD
Ericsson
4
2
6mm
LCD
LCD
Huawei
4
6mm2
LCD with IP seal
LCD
Nokia
2
4
6mm
LCD with RFE
LCD
Ericsson
4
6mm2
LCD
LCD
Huawei
4
2
LCD with IP seal
LCD
Nokia
6mm
*XXX represents length (mm) from end to end. E.g. L98Y-718-XXX means jumper length 5m.
40
Distribution Box Rosenberger ruggedized distribution box made of high-grade engineering plastic material provides the interconnection point between RRH jumpers and main FTTA trunk or hybrid cable assemblies. The distribution and interconnection of whatever main FTTA hybrid cable, fiber trunk cable and DC power trunk cable can be implemented seamlessly and flexibly over cost-effective Rosenberger distribution boxes. It supports up to 6/12 RRHs which makes the network cabling system installation, maintenance, upgrade and expansion possible and supports multi-vendor installations. Standard and customized distribution boxes are available.
41
Fiber Distribution Box
Description Rosenberger fiber distribution box can be used at tower top or at bottom for fiber management, and it provides cost-effective and flexible solution for installing multiple RRHs.
Feature and Benefit • Support up to 12 RRH • LC adapters pre-assembled • IP66 waterproof protection to fiber connections • One main entry for FTTA trunk • Up to three fiber jumper entries • Hinged cover • UV resistant • Mounting brackets and cable glands included
Specification
42
Number of RRH
Up to 12 RRH
Dimension (L x W x H)
300mm x 200mm x 132mm
Fiber Cores
Up to 24 fibers
Fiber Type
Both singlemode and multimode
Mounting
Pole, wall
Material
Polycarbonate
Cable Gland M25x1.5mm (Φ3-Φ7, mm)
Up to 4
Input Cable Diameter
FO cable (Φ3-Φ7mm)
output Cable Diameter
FO cable (Φ3-Φ7mm)
Sealing of Jumpers
Multihole cable glands
IP Rating
IP66
Operation Temperature
-40°C ~ +85°C
Earthing
Grounding cable
2011/65/EU (RoHS)
Compliant
Power Distribution Box
Description Rosenberger power distribution box can be used at tower top or at bottom for power management, and it provides cost-effective and flexible solution for installing multiple RRHs. The box can be supplied with overvoltage protective (OVP) device.
Feature and Benefit • Support up to 6 RRH • Power terminal block pre-assembled • IP66 waterproof protection to power connections • One main entry for power trunk • Up to three power jumper entries • Hinged cover • UV resistant • Mounting brackets and cable glands included • Circuit breaker options
Specification Number of RRH Dimension (L x W x H)
Up to 3 RRH and 4 RRH
Up to 6 RRH
200mm x 200mm x 132mm
300mm x 200mm x 132mm
Mounting
Pole, wall
Material
Polycarbonate 1
Cable Gland M40x1.5mm (Φ19-Φ28mm) Cable Gland M20x1.5mm (Φ8-Φ13mm) Sealing of Jumpers IP Rating Operation Temperature 2011/65/EU (RoHS)
2
2
6x6mm , 6x10mm , 2x16mm2, 2x25mm2
3
6 2
2
2x4mm , 2x6mm
Multihole cable glands IP66 -40°C ~ +85°C Compliant
43
Hybrid Distribution Box
Description Rosenberger Hybrid distribution box can be used at tower top or at bottom for both fiber and power management, and it provides costeffective and flexible solution for installing multiple RRHs. The box is with patented design by Rosenberger and is most suitable to be installed with Rosenberger EasyLinkTM hybrid cables.
Feature and Benefit • Support up to 6 RRH • LC adapters pre-assembled • Power terminal block pre-assembled • IP66 waterproof protection to fiber and power connections • One main entry for hybrid cable • Up to six hybrid jumper entries
• Hybrid cable and jumper grounded within box • Hinged cover • UV resistant • Mounting brackets and cable glands included • Circuit breaker options
Specification Number of RRH
Dimension (L x W x H) DC Power Fiber Cores
Up to 4 RRH
Up to 6 RRH
300mm x 300mm x 130mm
300mm x 400mm x 130mm
up to 4 pairs
up to 6 pairs
up to 16 fibers
Both singlemode and multimode
Mounting
Pole, wall
Material
Polycarbonate
Hybrid Trunk Cable
1 (7/8" cross-section)
2 (7/8" cross-section)
Hybrid Jumper
4 (1/2" cross-section)
6 (1/2" cross-section)
Sealing of Jumpers IP Rating Operation Temperature Earthing 2011/65/EU (RoHS)
44
up to 24 fibers
Fiber Type
Cable Gland M25x1.5mm(Φ11-Φ17mm) IP66 -40°C ~ +85°C Grounding cable Compliant
Installation Accessory Rosenberger designs, manufactures and supplies the complete series of installation accessories for wireless cellular site feeder system including cable clamp, hoisting grip, cable tie, grounding kit, grounding bar, hose clamp, weatherproof kit, cable entry kit, circuit breaker and etc. Particularly the standard sized cable clamps and grounding kits can be used as necessary for installing Rosenberger FTTA fiber cables and EasyLinkTM hybrid cables.
45
Cable Clamp
Description Rosenberger cable clamps are universal parts which work with different feeder cables and FTTA RRH installation solutions. They are easy to install and allow for an upgrade or exchange
of cables. The selected stainless steel and UV-resistant material guarantees the long-term site material installation quality which has been proven by many customers’ field application.
Ordering Information
46
Part Number
Description
Suitable Cable Size
SLCC111-C03
Single Hole Cable Clamp, 1-way
1/2"
SLCC121-C03
Single Hole Cable Clamp, 2-way
1/2"
SLCC131-C03
Single Hole Cable Clamp, 3-way
1/2"
SLCC111-C05
Single Hole Cable Clamp, 1-way
7/8"
SLCC121-C05
Single Hole Cable Clamp, 2-way
7/8"
SLCC131-C05
Single Hole Cable Clamp, 3-way
7/8"
SLCC111-C06
Single Hole Cable Clamp, 1-way
1-1/4"
SLCC121-C06
Single Hole Cable Clamp, 2-way
1-1/4"
SLCC131-C06
Single Hole Cable Clamp, 3-way
1-1/4"
SLCC211-C03
Double Hole Cable Clamp, 1-way
1/2"
SLCC221-C03
Double Hole Cable Clamp, 2-way
1/2"
SLCC231-C03
Double Hole Cable Clamp, 3-way
1/2"
SLCC211-C05
Double Hole Cable Clamp, 1-way
7/8"
SLCC221-C05
Double Hole Cable Clamp, 2-way
7/8"
SLCC231-C05
Double Hole Cable Clamp, 3-way
7/8"
SLCC211-C06
Double Hole Cable Clamp, 1-way
1-1/4"
SLCC221-C06
Double Hole Cable Clamp, 2-way
1-1/4"
SLCC231-C06
Double Hole Cable Clamp, 3-way
1-1/4"
SLCC211-ZF1
Two-Size Cable Clamp, 1-way
SLCC241-ZF1
Two-Size Cable Clamp, 2-way
SLCC261-ZF1
Two-Size Cable Clamp, 3-way
SLCC111-36.5
Hybrid Cable Clamp, 1-way
D36-37mm
SLCC121-36.5
Hybrid Cable Clamp, 2-way
D36-37mm
SLCC131-36.5
Hybrid Cable Clamp, 3-way
D36-37mm
SLCC115-32.5
Hybrid Cable Clamp, 1-way
D32-33mm
Fiber: Φ4.5 - Φ7mm ( Grey ) Power: Φ9 - Φ13mm ( Black )
Grounding Kits Description Considering the expensive telecommunication equipments, it is very important to set up the grounding well to prevent the equipment from the lighting strikes. The grounding kits are the key components which will be installed in field system every 4060m. Rosenberger grounding kits provide best diversion function and the selected material guarantees the long-term site material installation quality which has been proven by many customers’ field application.
Ordering Information Part Number
Description
Suitable Cable Size
SLGK001-C03-xxx1)
Grounding Kit with quick lock shielding
1/2"
1)
Grounding Kit with quick lock shielding
7/8"
SLGK001-C06-xxx1)
Grounding Kit with quick lock shielding
1-1/4"
1)
Grounding Kit with tread lock shielding
1/2"
SLGK004-C05-xxx1)
Grounding Kit with tread lock shielding
7/8"
1)
Grounding Kit with tread lock shielding
1-1/4"
Grounding kits for different series cable
All sizes
SLGK001-C05-xxx SLGK004-C03-xxx SLGK004-C06-xxx SLGKT003D-xxx
2)
Note 1), XXX is the length of grounding wire which in cm. E.g. P/N: SLGK001-C03-150 The length of grounding wire is 150cm.
Hoisting Grips Description Hoisting Grips are available for a wide range of coaxial and hybrid cable sizes, made up of mesh grip with single eye support and it allows for quick and efficient installation. Different types are available to be fit for most of different feeder cables and FTTA RRH installation solutions.
Ordering Information Part Number
Description
Suitable Cable Size
SLHG001-C03
Pre-placed Hoisting grips
1/2"
SLHG001-C05
Pre-placed Hoisting grips
7/8"
SLHG001-C06
Pre-placed Hoisting grips
1-1/4"
SLHG003-C03
Hoisting grips with open edge
1/2"
SLHG003-C05
Hoisting grips with open edge
7/8"
SLHG003-C06
Hoisting grips with open edge
1-1/4"
47
Fiber Optic Interconnect Products Rosenberger provides high quality fiber optic inter-connect products for supporting the communication equipment cross connection in switching and transmission rooms. All fiber optic patchcord and pigtail are designed, manufactured and tested to international standards IEC and Telecordia by long-term reliability performance guaranteed. Rosenberger fiber optic patch panel system is designed for EIA 19” rack and compatible with all common factory assembled or site-installed fiber cables, and most suitable to work with pre-assembled Rosenberger FTTA cables. Rack-mountable Rosenberger VelaTM fiber patch panel can reach up to 96-fibers LC connectivity in one height unit (1HU) dimension by also supporting MTP/MPO interface.
48
Patchcord & Pigtail
Description All industry standard fiber optic connectivity together with customized connectors are available from Rosenberger for terminating to all kinds of patchcord and/or pigtail at different
lengths. With great in-house manufacturing of fiber optic connector, cable and cable assembly, it provides Rosenberger the advantages of flexibility, superior quality and quick turn-around.
Application • Channel to channel connection of fiber optic lines installed within distribution panels or equipment • Connection of peripheral devices with a fiber optic interface
• On-site splicing with bulk cable • Other scenarios where fiber connection is required
Feature and Benefit • Fiber types: Singlemode 9/125μm (G652D, G657A/B), Multimode 50/125μm (OM2/OM3/OM4), Multimode 62.5/125μm (OM1) • Outer sheath made of riser, plenum or LSZH rated material • Available with simplex cable, duplex cable, mini-zipcord cable, ribbon cable, and other types of cables on request • UL or Anatel approved cable available • Available with ST, SC, FC, LC, MU, MTP/MPO, E2000, and other
types of connector on request • 100% performance tested • Providing test report for 3D geometric characteristics of connector end-face as required • Separately packed in plastic bag, including serial number and attenuation data, and other types of packing on request
Specification Fiber Fiber Type Multimode 62.5/125μm
Standard IEC 60793
ISO 11801
ITU-T G65X Series
A1b
OM1
N/A
OM2 Multimode 50/125μm
A1a
OM3
G651
OM4 B1.1
Singlemode 9/125μm
OS1
G652A/G652B
B1.2
N/A
G654
B1.3
OS2
G652C/G652D
B2
N/A
G653
B4
N/A
G655
B5
N/A
G656
B6
N/A
G657A/G657B
49
Optical Cable Cable Construction
Simplex Cable
Duplex Cable
1
2
Fiber QTY
Multi-Fiber Optical Cable
Mini-Cable 1
2
4/6/8/12
24
Diameter (mm)
2.0
3.0
2.0*4.1
2.9*5.8
1.6
1.6*3.3
3.0
3.6
Max. Tensile (N)
120
150
150
200
80
120
100
120
Max. Crush (N/10cm)
500
500
500
500
300
300
100
100
Min. Bending Radius (mm)
20
30
20
30
16
16
30
36
Temperature Range
-25℃ to +70℃
-20℃ to +70℃
Connector Connector Optical Interface Standard
Connector Type
Interfaces Standard
SC
IEC 61754-4
Radius
7~25mm
Radius
5~12mm
FC
IEC 61754-13
Fiber Height
-100~+50nm
Fiber Height
-100~+50nm
ST
IEC 61754-2
Apex Offset
≤ 50 μm
Apex Offset
≤ 50 μm
N/A
Angle
8± 0.3°
PC
8 degrees angled-PC (APC)
LC
IEC 61754-20
Angle
MU
IEC 61754-6
E2000
IEC 61754-15
Other parameter according to IEC 61755-3-1
MTP
IEC 61754-7
Other parameter according to IEC 61755-3-2
IEC 61755-3-32
Cable Assembly LC, SC, FC, ST, MU
Connector Type Fiber Type
SM
Insertion Loss (IL, dB) Return Loss (RL, dB) For UPC Return Loss (RL, dB) For 8°APC Max. Tensile (N) (Cable & Connector) Temperature Range
MM
E2000 SM
Max 0.3
MPO/MTP MM
Max 0.3
Standard
SM
MM
≤0.6
≤0.5
See table1 IEC 61300-3-4 Method B IEC 61300-3-6 Method 1 IEC 61300-3-6 Method 1
50
35
55
40
/
20
60
/
70
/
60
/
100
100
80
80
IEC 61300-2-4
-20℃ to +60℃
IEC 61300-2-22
70
-25℃ to +70℃
Ordering Information
HECM -
-
Fiber Optical Cable Assembly
Length (<1KM) XXXXXX = XXXXXX mm (≥1KM) XXX KM =XXX KM
Cores 1=1F 2=2F Cable Type O=naked H=LSZH G=PVC(OFNG) R=PVC(OFNR) P=PVC(OFNP)
50
Type Of Fiber 1=OM1 62.5/125um 2=OM2 50/125um 3=OM3 50/125um 7=G657A1 9=G652D A=G657A2
Shape of Cable Y=roll P=drop cable Z=8 figure
Cable Dia. 2=2.0mm 3=3.0mm 6=1.6mm 8=1.8mm 9=0.9mm
Cable color (If to be defined) BL=Blue OR=Orange GR=Green BR=Brown SL=Slate WH=White RD=Red BK=Black YL=Yellow VT=Violet RS=Rose RS=Rose AQ=Aqua
Connector A 1=ST 2=SC 3=FC 4=LC 5=LCD 9=E2000 C=MU D=SCD
Connector B 0=empty 1=ST 2=SC 3=FC 4=LC 5=LCD 9=E2000 C=MU D=SCD
Polishing Level (If to be defined) A=APC(pigtail) B=APC-APC C=PC-APC D=APC-PC E=PC(pigtail)
Fiber Patch Panel
Description Rosenberger HDCS® distribution & splice fiber optic patch panel insures good management for the four critical elements of fiber optic cable: bend radius protection, cable routing path, cable access and physical protection. Those four aspects directly affect the reliability, functionality and the operational cost of the network.
Rosenberger HDCS® patch panel is designed for 19" EIA rack, and compatible with all common factory assembled or siteinstalled fiber cables.
Feature and Benefit • • • • •
Patching and splicing The panel surface is treated with electro-static spraying Silk-screen printing for front plate labeling 45° entry for back cable, flexible cabling from left and right side Aluminum or steel material available
• Sliding-type and fixed-type available • Standard black and other colors available • Panel accessories can be ordered separately
Specification Sliding-type: 483 x 300 x 1HU (mm) and 483x 300 x 2HU (mm)
Fixed-type: 483 x 250 x 1HU (mm) and 483x 250 x 2HU (mm)
Delivery Form • Complete factory assembled panel • Dummy plugs in unused cable entries • Dummy plugs in unused front plate ports • Adapters ready in complete panel set
• 4 installation screws and caged-nuts as mounting kit • Cable gland & guiding clip • Splice trays included for complete panel set
Ordering Information
10 Digit 1 1: 1 HU Distribution Panel 2: 1 HU Splice Panel 3: 1 HU Sliding Distribution Panel 4: 1 HU Sliding Splice Panel
-
Digit 2 1: SC/SC simplex SM 4: SC/SC simplex MM 5: SC/SC Duplex SM 6: SC/SC Duplex MM C: LC/LC Duplex SM D: LC/LC Duplex MM E: FC/FC simplex G: SC/APC simplex K: E2000/E2000
Digit 3 2: 12 Fibers 3: 24 Fibers 4: 48 Fibers 6: 8 Fibers 7: 32 Fibers 8: 4 Fibers C: 6 Fibers D: 36 Fibers
Digit 4 5: Black
Digit 5 1A: Steel material
51
High Density VelaTM Modular Fiber Patch Panel
Description Rosenberger high density fiber optic patch panels are designed for 19" racks and compatible with common factory assembled or
on-site assembled cables, especially for Rosenberger factory preassembled cabling system.
Application Rosenberger distribution & splice fiber optic patch panel insures good management for the four critical elements of fiber optic cable: bend radius protection, cable routing path, cable access
and physical protection. Those four aspects directly affect the reliability, functionality and the operational cost of the network.
Feature and Benefit • Modular and ergonomic design with front and rear drawers for ease of installation and maintenance • Installable with standard 19" EIA rack • Max. 96 fibers capacity in 8 modules (2 layer x 4 modules/layer) • 12-fiber capacity of each module
• Fiber module accepts multimode 50/125μm OM2, 10G OM3, OM4 or a low water-peak singlemode fiber cable harness • Rear cabling manager with layered design and pull-out rotation function • Hidden draw-type label panel design
Specification Dimension MTP-LC Module Number of Fiber Slots Number for MTP-LC Module Max. Number of Fiber MTP-LC Module Attenuation(Typical)
Single-mode Multi-mode
Salt Mist Cyclic Test Installation Type Storage Temperature Operation Temperature
483mm x 509mm x 44.45mm 12F 8 96F 0.5dB 0.4dB 24H Fixed type and sliding type -40°C ~ +70°C -20°C ~ +60°C
Module and Accessories
VelaTM Blind Cover
12F MTP-LC duplex VelaTM Modules
Ordering Information Ordering Number Fiber Patch Panel CPB1-110-41 CPB1-110-51 MTP-LC Module CPB2-251-12 CPB2-253-12 CPB2-254-12 CPB2-255-12 Blind Cover CPB4-611-11
52
Description VelaTM 1HU Modular Fiber Patch Panel Fixed Type, Black, without Module VelaTM 1HU Modular Fiber Patch Panel Pull-out, Black, without Module VelaTM MTP -LC Module B, 12F, SM VelaTM MTP -LC Module B, 12F, OM2 VelaTM MTP -LC Module B, 12F, OM3 VelaTM MTP -LC Module B, 12F, OM4 VelaTM Blind Cover
Copper Connectivity Solution Rosenberger has leading copper connectivity solution which covers data, video and voice transmission application in telecommunication and electronics industry. All kinds of copper cable assembly, terminal module, distribution frame and box are available to help operators and other customers set up a high efficiency communication transmission network. High quality product, technical consultancy and support, best lead time and excellent after-sales service are supported by Rosenberger. • D-Sub Series Cable Assembly • Ethernet Patch Panel • LSA Module and Distribution Unit
• RJ45 Ethernet Cable Assembly • Balun Panel • Other Customized Solution
53
D-Sub Series Cable Assembly
Description Rosenberger provides different forms of D-sub cable assembly whice are to be widely used for data transmission between communication and control equipments.
Application • • • •
• • • •
Cellular base station Network switching Transmission Routers
Multiplexers Mainframes Engineering Workstations Computers/Printers/Scanners
Feature and Benefit • Small to large size with different pins • Easy to install and unload without specialized tooling • 100% factory assembled and tested
• Applicable to various equipments and interfaces • Series of standard density and high density • Standard or customized cable
Specification
54
Product Series
Shell Size (mm)
Current (A)
Wire Size (AWG)
Contact Styles
Standard Density
9, 15, 25, 37, 50
5
28-18
Solder or Crimp
High Density
15, 26, 44, 62, 78
2
28-22
Solder or Crimp
RJ45 Ethernet Cable Assembly CAT5e Patch Cord
Description Rosenberger CAT5e patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth network applications and is especially suitable to IEC 11801 Class D standard requirements.
Application • • • •
VoIP ISDN Token ring 100 Mbps TP-PMD
• • • •
Analog and digital video TR-16 Active and Passive 155 Mbps /622 Mbps ATM 10BASE-T/100BASE-TX Fast Ethernet
Feature and Benefit • Designed for both unshielded and shielded cabling system • Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard and 100% factory tested • Adopt arc-shaped snagless boot design for elastic latch protection • Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance
• Outer jacket PVC or LSZH • Different colored cable jacket option • Flexible ladder-shaped boot design provides better cable bending protection
Specification Electrical Performance Frequency (MHz)
2m Cord
NEXT (dB) 5m Cord
10m Cord
RL (dB)
1
65.0
65.0
65.0
19.8
4
62.3
61.5
60.4
21.6
8
56.4
55.6
54.7
22.5
10
54.5
53.7
52.8
22.8
16
50.4
49.8
48.9
23.4
20
48.6
47.9
47.1
23.7
25
46.7
46.0
45.3
24.0
31.25
44.8
44.2
43.6
23.0
62.5
39.0
38.5
38.1
20.0
100
35.1
34.8
34.6
18.0
55
RJ45 Ethernet Cable Assembly CAT6 Patch Cord
Description Rosenberger CAT6 patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth network applications, and is especially suitable to IEC 11801 Class E standard requirements.
Application • • • •
• • • •
VoIP ISDN Token ring 100 Mbps TP-PMD
Analog and digital video TR-16 Active and Passive 155 Mbps /622 Mbps /1.2 Gbps ATM 10BASE-T/100BASE-TX Fast /1000BASE-TX Gigabit Ethernet
Feature and Benefit • Designed for both unshielded and shielded cabling system • Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard and 100% factory tested • Adopt arc-shaped snagless boot design for elastic latch protection • Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance
• Outer jacket PVC or LSZH • Different colored cable jacket option • Flexible ladder-shaped boot design provides better cable bending protection
Specification Electrical Performance
56
NEXT (dB)
Frequency (MHz)
2m Cord
5m Cord
10m Cord
RL (dB)
1
65.0
65.0
65.0
19.8
4
65.0
65.0
65.0
21.6
8
65.0
65.0
64.8
22.5
10
65.0
64.5
62.9
22.8
16
62.0
60.5
59.0
23.4
20
60.1
58.6
57.2
23.7
25
58.1
56.8
55.4
24.0
31.25
56.2
54.9
53.6
23.0
62.5
50.4
49.2
48.1
20.0
100
46.4
45.3
44.4
18.0
125
44.5
43.5
42.7
17.0
150
43.0
42.1
41.4
16.2
175
41.8
40.9
40.2
15.5
200
40.6
39.8
39.3
15.0
225
39.7
38.9
38.4
14.5
250
38.8
38.1
37.6
14.0
RJ45 Ethernet Cable Assembly CAT6A Patch Cord
Description Rosenberger CAT6A patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth applications, and is especially suitable IEC 11801 to Class EA standard requirements.
Application • • • • •
VoIP SDN Token ring 100 Mbps TP-PMD Analog and digital video
• TR-16 Active and Passive • 155 Mbps /622 Mbps /1.2 Gbps ATM • 10BASE-T/100BASE-TX Fast /1000BASE-TX Gigabit Ethernet/10Gbase-T Gigabit Ethernet
Feature and Benefit • Designed for both unshielded and shielded cabling system • Comply with Fluke DTX-1800 / TIA568C.2 patch cord standard and 100% factory tested • Adopt arc-shaped snagless boot design for elastic latch protection • Utilizing flexible stranded patch cable • Connector contacts 50μ” gold plated minimizing contact resistance
• Outer jacket PVC or LSZH • Different colored cable jacket option • Flexible ladder-shaped boot design provides better cable bending protection
Specification Electrical Performance NEXT (dB)
Frequency (MHz)
2m Cord
5m Cord
10m Cord
RL (dB)
1
65.0
65.0
65.0
19.8
4
65.0
65.0
65.0
21.6
8
65.0
65.0
64.8
22.5
10
65.0
64.5
63.0
22.8
16
62.0
60.5
59.1
23.4
20
60.1
58.6
57.3
23.7
25
58.1
56.8
55.4
24.0
31.25
56.2
54.9
53.6
23.0
62.5
50.4
49.2
48.1
20.0
100
46.4
45.4
44.5
18.0
200
40.7
39.9
39.3
15.0
250
38.9
38.1
37.7
14.0
300
36.2
35.9
35.8
12.8
400
31.9
32.1
32.5
10.9
500
28.4
29.0
29.8
9.5
57
Customized Assembly Type
Description
Specification
8 Pair 120Ω PCM cable assembly is used for the serial transmission of data with good EMI performance, low bit-error and steady transmission rate.
Parts • Connector: RJ45 8P8C connector (shielded) • Cable: AWG 26 120Ω 8-pair Assembly • Insulation resistance ≥100MΩ • Dielectric strength AC, 250V, 1sec
16 Pair 120Ω PCM cable assembly is used for the serial transmission of data with good EMI performance, low bit-error and steady transmission rate.
Parts • Connector: RJ45 8P8C connector (shielded) • Cable: AWG 26 120Ω 8-pair Assembly • Insulation resistance ≥100MΩ • Dielectric strength AC, 250V,1sec
RS BT43 straight single cable assembly connects to DDF or communication switching equipment for transferring the digital signals.
Parts • Connector: BT43 75Ω connector • Cable: RS Multi 8*Coax Cable Assembly • Insulation resistance ≥100MΩ • Dielectric strength AC, 250V, 1sec
Multi-RJ45
Multi-RJ45
BT43 (SMZ) R S E 1 / T 1 1 2 0 Ω C a b l e A s s e m b l y Parts p r o v i d e s t h e d i g i t a l t r a n s m i s s i o n • Connector: 4*TQ connector, 120Ω • Cable: AWG 26 120Ω 8-pair between communication equipments. Assembly • Dielectric strength AC, 250V, 1sec TQ Straight SCSI PCM cable assembly provides the digital transmission between communication equipments. High compact design with metal shell for good EMI performance.
Parts • Connector: MDR IDC Plug 36Pin, Male • Shell: MDR Metal Junction shell 180°exit • Cable: AWG26 120Ω SFTP PCM Cable Assembly • Insulation resistance ≥100MΩ • Dielectric strength AC, 250V, 1sec
MDR68-MDR68 with IP seal cable assembly provides the digital transmission between communication equipments. It can be used in outdoor enviroment with good water/dust proof performance.
Parts • Connector: MDR 68Position, Male • Shell: MDR metal junction shell • Cable: AWG26 100Ω SFTP PCM Cable, Halogen free, Black Assembly • Insulation resistance ≥10MΩ • Dielectric strength AC, 250V, 1sec
SCSI
SCSI
58
Type
Description
Specification
Mini SNAP cable assembly is widely used in automation control and communication industry. Push-pull self-locking results safe and quick connection or release.
Parts • Connector: Mini SNAP 4Pin Female • Cable: SEYVP 1*2/2*0.4 120Ω Assembly • Insulation resistance ≥100MΩ • Dielectric strength AC, 250V, 1sec
This cable assembly is used for signal transmission. One end is RJ45 plug with seal boot, and the other end is Coax 1.0/2.3 plug with seal boot. It can be used in outdoor enviroment with good water/dust proof performance..
Parts • Connector: RJ45 8P8C with seal boot • Connector: 1.0/2.3 straight plug with seal boot, 75 Ohm • Cable 1: Cat.5e 24AWG*4P SFTP • Cable 2: RG179 Assembly • Insulation resistance ≥20MΩ • Dielectric strength AC, 250V,1sec
Mini SNAP
RJ45- coax 1.0/2.3
Emily-RJ45 signal cable assembly Parts combines signal and power transmission • Connector A&B: Emily connector, Female • Cable: 30AWG 6PR parallel cable, LSZH in one connector system. Assembly • Insulation resistance ≥10MΩ • Dielectric strength AC, 250V, 1sec Emily-RJ45 Socket Emily cable assembly combines signal Parts and power transmission in one connector • Connector A&B: Emily connector, Female • Cable: 30AWG 6PR parallel cable, LSZH system. Assembly • Insulation resistance ≥10MΩ • Dielectric strength AC, 250V, 1sec Emily- Emily
Densi Shield
This cable assembly supports the transmission of high-speed serial differential signals. It combines high density, mechanical robustness and PCB assembly with excellent shielding and signal integrity performance.
Parts • Connector: Densi-shield I/O Plug • Cable: AWG26 100Ω 4P SF/UTP, LSZH Assembly • Insulation resistance ≥5MΩ • Dielectric strength AC, 250V, 1sec
59
Ethernet Patch Panel Description Rosenberger Ethernet modular patch panel is designed for both unshielded and shielded cabling system with excellent transmission performance, and which are compatible with all Rosenberger HDCS® modules. It has extremely high flexibility, adaptability and most compact design for supporting up 48 ports per height unit (HU). Rosenberger develops and supplies all levels
of Ethernet patch panel including for supporting CAT5e, CAT6 and CAT6A performance transmission as per IEC 11801 and TIA568-C.2 standards. Many of Rosenberger Ethernet patch panels are tested and certified by ETL-USA laboratory and other 3 rd parties.
CAT5e Modular Patch Panel
Application • 10baseT Ethernet • 100baseTX Fast Ethernet • 155Mbit ATM • 622Mbit ATM • TR-16 Active • TR-16 Passive
Feature and Benefit • Exceed the specification of TIA 568-C. 2 Category 5e requirements • Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence • Delivered with plastic cable management bar, installation screws and labeling system • Unshielded and shielded option • 24-port or 48-port per height unit (HU)
Specification Material
Electrical Property
Front Pane
Steel, powder coating
Plastic
High impact flame retardant Contact Resistance plastic, UL94V-0 rated
20MΩ Max.
Contact
Phosphor bronze C5210EH
500MΩ Min.
Contact Plating
Gold plating 50μ" over nickel Dielectric Strength plating 50~100μ"
Mechanical Property
60
Plug Insertion Life
≥750 times
Plug Retention Force
≥30 Lbs
Temperature Range
-40°C to +70°C
Current Rating
Insulation Resistance
1.5 AMP
750V AC RMS 60Hz 1MIN
Ethernet Patch Panel
CAT6 Modular Patch Panel
Application • 10baseT Ethernet • 100baseTX Fast Ethernet • 1000baseTX Gigabit Ethernet • 155Mbit ATM • 622Mbit ATM • TR-16 Active • TR-16 Passive
Feature and Benefit • Exceed the specification of TIA 568-C. 2 Category 6 requitments • Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence • Delivered with plastic cable management bar, installation screws and labeling system • Unshielded and shielded option • 24-port or 48-port per height unit (HU)
Specification Material
Electrical Property
Front Panel
Steel, powder coating
Plastic
High impact flame retardant Contact Resistance plastic, UL94V-0 rated
Current Rating
20MΩ Max.
Contact
Phosphor bronze C5210EH
500MΩ Min.
Contact Plating
Gold plating 50μ" over nickel Dielectric Strength plating 50~100μ"
Insulation Resistance
1.5 AMP
750V AC RMS 60Hz 1MIN
Mechanical Property Plug Insertion Life
≥750 times
Plug Retention Force
≥30 Lbs
Temperature Range
-40°C to+70°C
61
Ethernet Patch Panel
CAT6A Modular Patch Panel
Application • 10baseT Ethernet • 100baseTX Fast Ethernet • 1000baseTX Gigabit Ethernet • 10Gbase-T Gigabit Ethernet • 155Mbit ATM • 622Mbit ATM • 1.2 Gbit ATM • TR-16 Active/ Passive
Feature and Benefit • Exceed the specification of TIA 568-C. 2 Category 6A requirements • Outstanding performance including IL, NEXT/FEXT and RL guaranteeing good channel performence • Delivered with plastic cable management bar, installation screws and labeling system • Unshielded and shielded option • 24-port per height unit (HU)
Specification Material
Electrical Property
Front Panel
Steel, powder coating
Plastic
High impact flame retardant plastic, Contact Resistance UL94V-0 rated
20MΩ Max.
Contact
Phosphor bronze C5210EH
500MΩ Min.
Contact Plating
Gold plating 50μ over nickel plating Dielectric Strength 50~100μ
Mechanical Property Plug Insertion Life Plug Retention Force
≥30 Lbs
Temperature Range
-40°C to+70°C
62
≥750 times
Current Rating
Insulation Rresistance
1.5 AMP
750V AC RMS 60Hz 1MIN
Balun Panel
Balun Panel BNC to RJ45
Description BNC to RJ45 impedance matching balun panel provides 75Ω coax (BNC connector) to 120Ω twisted pair (RJ45 connector) conversion for 16 E1 channels (Tx and Rx). The panel conforms to
ITU-T G.703, matching the impedance and signal characteristics of up to 32 unbalanced 75Ω coax connections with up to 16 balanced 120Ω twisted pair connections.
Application The balun panel can be used for T1/E1/CPE network transmission equipment and other applications.The balun panel can provide
120Ω G.703 service whereas customers retaining 75Ω CPE hardware and vice versa
Feature and Benefit • Connects 75Ω dual coax to 120Ω twisted pair (or vice versa) • Bi-directional signal conversion according to ITU-T G.703 • Data rates up to 2.048 Mbps • Low profile design
• Mounts in standard 19" rack (1HU) • No power supply required • Female coax BNC connectors
Specification Parts Coaxial Connector Twisted Pair Connector Panel Electrical Data At 20°C Insertion Loss Cross Talk @1~100MHz Return Loss Insulation Resistance Operating Condition
Female BNC, 32pcs Female shielded RJ45, 16pcs 19", Steel, Zinc sealed and power coated, black ≤ 0.35dB ≥ 50dB ≥ 18dB ≥ 100MΩ
Matching Impedance
75Ω unbalanced coaxial to 120Ω balanced twisted pair connections
Bit Rate Environmental Data Temperature Range 2011/65/EC (RoHS)
2Mbit/s(E1) ITU-T G.703 -40°C to +85°C Compliant
63
Balun Panel
Balun Panel Coax to IDC
Description The rack mounting Balun Panel converts 16 G.703 E1 or E2 circuits from unbalanced 75Ω coaxial to balanced 120Ω twisted pair transmissions. Modular construction allows the user to hot swap modules for other bit rates, functions or interfaces. G.703/G.704 toolless insulating displacement connecting (IDC)
baluns are impedance matching 75Ω coax to 120Ω singleconductor connections. Various industry standard types of coaxial connectors (75Ω) are available including male and female combinations of BNC, 1.6/5.6, 1.0/2.3, and Type 43.
Application A bi-directional device requiring no external power which connects telecommunications equipment with mismatching interfaces or
facilitates the conversion from coaxial to twisted pair distribution wiring.
Feature and Benefit • Convert 75Ω Coax to 120Ω twisted pair--resolves impedance mismatch between twisted pair and coax cabling • Ultra-miniature IDC balun providing maximum density • Industry standard coax connectors including BNC, 1.6/5.6, 1.0/2.3 and Type 43 are available
64
• Mounts in standard 19" rack (1HU) • Low insertion loss meeting ITU-T (CTR-12) G.703 standards • No power supply required
Specification Parts Type
1.0/2.3 female to IEC169-29 Body Material
Coaxial Connector
Brass gold plated
Pin Material
Beryllium copper, plated cu/Ni5/Au1.25
Insulator Material
Teflon
Mating cycles
500min
Wire Conductor Size IDC Connector
Φ0.4 to Φ0.63mm
Insulation
0.7 to 1.1mm
Moulding Material
Polycarbonate White
Mating Cycles
50min
Coaxial IDC Moulding Material Panel
PC, Black Size Material
Standard 19" rack mountable Steel, Zinc sealed and power coated black
Electrical Data At 20°C Insertion Loss
≤0.15dB from 51KHz to 3.072MHz(2M bit/s) ≤0.20dB from 211KHz to 12.673MHz(8M bit/s)
Return Loss Pulse Shape Cross Talk Isolation Voltage
Exceeds G.703 requirements by >13dB for 2M bit/s
by >8dB for 8M bit/s
Exceeds G.703 requirements for 2Mbit/s and 8Mbit/s >65dB from 211KHz to 12.673MHz between channel >55dB for adjacent module contacts >250V DC
Operating Condition Matching Impedance Bit Rate Signal Level
75Ω unbalanced coaxial to 120Ω balanced twisted pair connections 2Mbit/s(E1) and 8Mbit/s(E2) ITU-T G.703 Line code 2.37V nominal peak voltage at the coaxial end per G.703
Environmental Data Temperature Range
-40 °C to +85 °C
2011/65/EC (RoHS)
Compliant
65
LSA Module and Distribution Unit LSA Termination Module
Description Rosenberger LSA module is specially designed for wall wounted box and MDF rack. It has connection and disconnection models, and is convenient to be used for PCM cable connection. It is suitable for use in all communication networks such as DSL and IP network.
Application • Main distribution frames • Data and PABX distribution • Cross-connection cabinets
• Internal and external distribution point • VDSL2-capable • Outdoor enclosures with restricted space for cable termination
Feature and Benefit • 5, 8, 10 pairs disconnection and connection module available • Folded double–layer and double-slot terminal with silver–plated surface • Lower contact resistance and high pull off force
• Aligning slot for each pair of wiring • Plastic shield over the terminals prevents from getting hurt • Clear identification mark for each pair of wiring
Specification Mechanical Property Housing Material
PBT fire-retardant, UL94V-0
Contact Material
Phosphor bronze, C5191H
Plating
200μ’’ silver plating over nickel plating
Allowed Wire
0.32-0.8mm
Contact Pin Life
≥ 200 times
Pull Off Force
≥ 25N
Electrical Characteristics
66
Voltage Rating
12 VAC
Current Rating
1.5AMP
Insulation Resistance
≥ 1000Mohm@ 500VDC
Contact Resistance Between Terminals
≤3 milliohm
Dielectric Strength 1000V
1min, (45~60) Hz
LSA Module and Distribution Unit LSA Distribution Box
Description The LSA distribution box is designed for both indoor and outdoor application, and can be mounted on the wall. There is a mounting frame for fixing 2/10 or 2/8 LSA connection module or compatible disconnection module inside the box.
Application It is suitable for PCM cable connection in all communication networks such as DSL and IP network.
Feature and Benefit • Supplied with or without LSA modules • Support up to 20pcs of LSA module or other capacity • Lockable design • Over-voltage protection (OVP) device option • Customized design available on request
Specification Box Capacity Box Size Box Material Frame Material Modules Endurance Operating Temperature
50 pair
100 pair
200 pair
320x240x110mm
320x320x110mm
400x600x110mm
ABS, thickness 3mm Stainless steel 100 Cycles (Min) -40°C to +65°C
2011/65/EU (RoHS)
Compliant
Flammability Rating
UL94V-0
Waterproof Performance
IP54
67
LSA Module and Distribution Unit LSA Distribution Frame
Description Rosenberger LSA distribution frame is very convenient to be used for connecting and distributing PCM cables, which is designed in a shape of ESTI 3HU for installing on a standard 19” open frame or rack. The distribution frame can be installed with up to 15pcs of LSA terminal module providing 150-pair wiring and transmission capacity.
Application It is suitable for PCM cable connection in all communication networks such as DSL and IP network.
Feature and Benefit • Termination block with 120Ω characteristic impedance • Installed on standard 19" open frame for better cable management • 3HU frame is suitable for small size exchange office
• Clear and tidy cabling • 50 pairs, 100 pairs, 150 pairs capacity available • Installation accessory attached
Specification Material Frame Material
Stainless steel
Thickness
1.5mm
Terminal Material
PBT fire-retardant ,UL94V-0
Contact Material
Phosphor bronze
Plating
200μ’’ silver plating over nickel plating
Allowed Wire
0.32-0.8mm
Contact Pin Life
≥ 200 times
Pull Off Force
≥ 25N
Electrical Characteristics
68
Voltage Rating
12 VAC
Current Rating
1.5AMP
Insulation Resistance
≥ 1000Mohm@ 500VDC
Contact Resistance Between Terminals
≤3 milliohm
Dielectric Strength 1000V
1min, (45~60) Hz
Power Cable Assembly Many of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connectivity interface. Particularly for remote radio head (RRH) application which requires power-to-the-antenna (PTTA), Rosenberger has a power design tool including calculation formula to tell following questions. • What
is the maximum allowable power consumption of RRH load with a desired cable design? is the required cable configuration including conductor cross section of DC power cable at a certain tower height? • What is the maximum allowed cable length between RRH and power supply unit with a specified cable cross section and RRH (power consumption level)? • What
69
Indoor D-sub Type High Power Cable Assembly
Description Rosenberger D-sub type cable assembly is used for high-power DC transmission in an indoor enviroment. The cable assembly has multi-pin D-sub connectors at both ends with male or female terminals.
Application Ideal as an input/output of D-sub power interface. The high quality D-sub connector has mixed contact sizes for signal, power, coax, thermocouple and high voltage applications.
Feature and Benefit • Power supply between transmission equipment • High Power Connector/ Combo D-sub connector • Support up to 40A high current
Specification Parts Connector A Connector B
D-sub body 2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8… D-sub body 2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8…
Connector Material
Brass, gold plated over nickel
Back Shell
Zinc Alloy, Matt nickel plated
Cable
Power Cable, Shielded, LSZH or PVC Jacket
Connector Electrical Characteristics Current Rating
10A, 20A, 30A, 40A
Contact Resistance
10MΩ Max.
Insulation Resistance
5000MΩ, Min.
Dielectric Withstanding
1000V AC
Environmental Data Installation Temperature
70
-10 °C to +65 °C
Operation Temperature
-20 °C to +75 °C
2011/65/EU (RoHS)
Compliant
Indoor ET 2-Pole Power Cable Assembly
Description The ET 2 pole power cable assembly is used for power distribution units with small form connector. The ET connector is a low loss, highly reliable and cost effective solution for cable-to-pcb application.
Application • • • •
Power distribution Cellular base station sites Computer servers and storage systems Industrial electronic equipment cabinets
Feature and Benefit • • • • •
High reliability Low profile right angle Right-angle and vertical mounts available for ET connector 16AWG, 14AWG, 12AWG, 10AWG wire cables for option Up to 30 Amps per contact
Specification Parts Connector
ET Power connector
Power Contact
Copper alloy with coating
Cable Conductor Size
16AWG, 14AWG, 12AWG, 10AWG
Cable Conductor Structure
Stranded / Solid tinned copper
Cable Jacket
Halogen free, Black
Electrical Characteristics Current
Max 30A per contact
Environmental Data Installation Temperature
-10 °C to +65 °C
Operation Temperature
-40 °C to +70 °C
2011/65/EU (RoHS)
Compliant
71
Outdoor IP67 Power Cable Assembly
Description Many of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connection interface. Rosenberger provides such power cable assembly in conjunction with hybrid FTTA solution, which is usually terminated at one end with 2-pole or 3-pole outdoor power connector for connecting with hybrid cable and the other end left open.
Application Most applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid cable assembly.
Feature and Benefit • • • • •
Compatible with EasyLinkTM hybrid trunk Terminated with a IP67 connector and blunt cut on the RRH side Pluggable power supply interface 12AWG or 10AWG gauge wire for option Strong tensile and crush capability
Specification Parts Number of Connector Poles Cable Conductor Cable Ingress Protection Cable Jacket Material Cable Braid Cable Diameter Cable Bending Radius
2 or 3 4mm2 (12AWG) IP67 PVC, UV-resistant, Black
Bare copper 9.2mm
Environmental Data Operation Temperature Installation Temperature 2011/65/EU (RoHS)
72
11.2mm
Operation Installation
12×outer diameter 6×outer diameter
Wire to Earth Wire to Wire
≤ 3.30Ω/km ≥ 5 MΩ•km 0.6 kV 1 kV
Electrical Characteristics DC resistance of conductor Insulation resistance Rating Voltage
6mm2 (10AWG)
-40 °C to +70 °C -20 °C to +60 °C Compliant
Outdoor IP65 Power Cable Assembly
Description Many of today’s communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and connection interface. Rosenberger provides such multi-beam 2-pole power cable assembly in conjunction with hybrid FTTA solution, which is usually terminated at one end with 2-pole multi-beam connector for connecting with RRH and the other end left open.
Application Most applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid cable assembly.
Feature and Benefit • • • • • •
Provides contacts for power distribution and power control Rugged Blind-Mate connector system Pluggable power supply interface Flexible Power crimp-to-wire terminations accommodate 8AWG, 10AWG and 12AWG wire for option Stamped and selectively plated power contacts provide a cost effective solution
Specification Parts Connector Type
Multi-beam 2P power connector with seal boot, IP65
Connector Contacts Material
Copper based alloy
Connector Housing Material
Glass-filled high temperature nylon, black
Cable Conduct Size
8 AWG
Cable Conduct Structure
10 AWG
12 AWG
14 AWG
Stranded bare copper
Cable Jacket Material
PVC, UV-resistant, Black
Electrical Characteristics Current Rating Voltage Rating Dielectric Strength Insulation Resistance Dielectric Strength
45A
35A
25A
20A
105C, 600V DC 1500V, 1min ≥20 MΩ AC 500V, 1sec
Environmental Data Installation Temperature
-15 °C to +60 °C
Operation Temperature
-35 °C to +80 °C
2011/65/EU (RoHS)
Compliant
73
Fiber Optic Connectivity A fiber optic connector is a disconnectable device used to connect a fiber to a source, detector or another fiber. It is targeted to be designed for easy connecting and disconnecting many times. Connection by fiber optic connectors couples light from one component to another with as little loss of optical power as possible, since the interconnection of various components of a fiber optic network system is a vital part of system performance. Rosenberger, with over 20 years of experience, has designed and supplied various fiber optic connectors to the market with desirable features including low loss, easy installation, high repeatability, consistency quality and cost-effective material. Particularly for today and tomorrow’s wireless communication network and cellular sites, Rosenberger can provide all industry standard and specialized fiber connectivity solution to fulfill high performance requirements.
74
Rosenberger Multi-fiber Connector (RMC™)
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Feature and Benefit • • • •
Multi-fibers connector, 4/6/8/12/24 fibers are available Support singlemode and multimode Robust connector system with screwed locking mechanism Components of the N coaxial connector according to MILPRF-39012 enable a conversion • With the standard panel cutout, the receptacle can easily replace a coaxial connector type
• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67 • Captive protection cap, plastic dust cap and metal cap without rope are available • Cable connector (male/female) and flange connector (female) are available
Specification Standard
IEC 61753-1 Cat. E
Housing Material
Nickel-plated brass
Ferrule Material
PPS
Operating Temperature
-40°C~+80°C (dependent on cable type)
Ingress Protection (Mated)
IP67 (IEC 60529)
Mechanical Resistance
>600N
Mating Cycles
>=500
Suitable Cables (mm)
D2.0/ D6.0/ D7.0
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
75
Rosenberger Quad Connector (RQC)
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Feature and Benefit • • • •
4 fibers connector Support singlemode and multimode Robust connector system with screwed locking mechanism Components of the N coaxial connector according to MILPRF-39012 enable a conversion • With the standard panel cutout, the receptacle can easily replace a coaxial connector type
• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67 • Captive protection cap, plastic dust cap and metal cap without rope are available • Cable connector (male/female) and flange connector (female) are available
Specification
76
Standard
IEC 61753-1 Cat. E
Housing Material
Nickel-plated brass
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+125°C (dependent on cable type)
Ingress Protection (mated)
IP67 (IEC 60529)
Mechanical Resistance
>600N
Mating Cycles
>=1000
Suitable Cables (mm)
D4-D7 (Mini) breakout or D1.7 Simplex cable
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
Rosenberger Duplex Connector (RDC)
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Feature and Benefit • • • •
2 fibers connector Support singlemode and multimode Robust connector system with screwed locking mechanism Components of the N coaxial connector according to MILPRF-39012 enable a conversion • With the standard panel cutout, the receptacle can easily replace a coaxial connector type
• Mated or with attached protection cap, plug and receptacle are sealed according to IEC 60529 IP67 • Captive protection cap, plastic dust cap and metal cap without rope are available • PC and APC are available • Cable connector (male/female) and flange connector (female) are available
Specification Standard
IEC 61753-1 Cat. E
Housing Material
Nickel-plated brass
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+125°C (dependent on cable type)
Ingress Protection (mated)
IP67 (IEC 60529)
Mechanical Resistance
>600N
Mating Cycles
>=1000
Suitable Cables (mm)
D4-D7 (Mini) breakout or D1.7 Simplex cable
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
77
Rosenberger Efficient Connector (REC)
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Feature and Benefit • • • • • •
Standard LC duplex connector interface Support singlemode and multimode Robust connector system with bayonet locking mechanism Support connection with SFP module Easy manual installation Waterproof, dust proof and corrosion resistant
Specification
78
Mating with ODVA connector
From TE and Conec
Nut Material
Aluminium alloy, black oxide treated
Housing Material
PA
Gasket Material
Silicon
Operating Temperature
-40°C~+85°C (dependent on cable type)
Ingress Protection (mated)
IP67 (IEC 60529)
Mechanical Resistance
>600N
Mating Cycles
>=1000
Suitable Cables (mm)
D4-D7
Connector Type
Standard LC duplex
2011/65/EU(RoHS)
Compliant
LC Loopback Connector
Description LC Loopback is with standard LC duplex connector interface, available both single mode and multimode version. It is to make both optical contacts connected together inside the packing which allows a self-test for device or a measurement of a link from one side. It can be used for trouble shooting in field and also can be used to make transceiver test in research and development labs.
Feature and Benefit • Standard LC duplex connector interface • Support singlemode and multimode individually • Packing sizes fit for small space application • Reliable protection for loopback fiber • Easy manual installation
Specification Standard
IEC 60754-20
Housing Material
PEI
Ferrule Material
Zirconica ceramic
Insertion Loss (Typical) Insertion Loss (Max.)
Singlemode ≤0.5dB @1310nm&1550nm Multimode ≤0.4dB @850nm&1300nm Singlemode≤1.0dB @1310nm&1550nm Multimode ≤0.7dB @850nm&1300nm
Operating Temperature
-40~+75°C
Mating Cycles
>=500
Flammability Rating
UL 94-V0
2011/65/EU (RoHS)
Compliant
Order Information Part number
Description
98E-118
LC Loopback, Singlemode, 9/125μm fiber
98E-119
LC Loopback, Multimode, 50/125μm fiber
98E-120
LC Loopback, Multimode, 62.5/125μm fiber
79
LC Connector
Description Using as flexible connection joint in fiber optic network, where there is devices with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.
Feature and Benefit • • • • • • • •
Small Form Factor (SFF) single-fiber connector Support singlemode and multimode Simplex and duplex Latched push-pull locking mechanism Spring loaded ferrule, aligned in a slotted sleeve Tuning possible Dust caps are available PC/UPC/APC is available
Specification
80
Standard
IEC 61754-20
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+85°C (dependent on cable type)
Mating Cycles
>=1000
Suitable Cables (mm)
D0.9-D3.0 or D5.0 with duplex connector
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
SC Connector
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.
Feature and Benefit • Single-fiber connector • Support singlemode and multmode • Simplex and duplex • Push-pull locking mechanism • Spring loaded ferrule, aligned in a slotted sleeve • Tuning possible • Dust caps are available • PC/UPC/APC is available
Specification Standard
IEC 61754-4, EN 50377-4
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+85°C (dependent on cable type)
Mating Cycles
>=1000
Suitable Cables (mm)
D0.9-D3.0 or D5.0 with duplex connector
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
81
MU Connector
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.
Feature and Benefit • Single-fiber connector • Support singlemode and multimode • Simplex, duplex horizontal and vertical • Push-pull locking mechanism • Spring loaded ferrule, aligned in a slotted sleeve • Tuning possible • Dust caps are available • PC/UPC/APC are available
Specification
82
Standard
IEC 61754-6; EN50377-10
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+85°C (dependent on cable type)
Mating Cycles
>=1000
Suitable Cables (mm)
D0.9-D3.0
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
E2000TM Connector
Description Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment. Typical is for mobile communication (FTTA), LAN, Data center network application.
Feature and Benefit • • • • • •
Single-fiber connector Singlemode and multimode Simplex, duplex and duplex-compact Latched push-pull locking mechanism Spring loaded ferrule, aligned in a slotted sleeve Metal cap and plastic cap are available
Specification Standard
IEC 61754-15, EN 50377-8
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
-40°C~+85°C (dependent on cable type)
Mating Cycles
>=1000
Suitable Cables (mm)
D0.9-D3.3, Diamond up to D3.5mm
Fiber Types
OS2, OM1, OM2, OM3, OM4
2011/65/EU(RoHS)
Compliant
83
Rosenberger Fiber Enclosure (RFE) Description possible for outdoor use and applicable for small cells, radio links, RRHs, and distribution boxes.
• For cable diameters from 4.5mm up to 9mm and the connectors with outer diameter of < 17.3mm. e.g. LC-Duplex, MTP®, RJ45 and USB • Enables pre-assembling of cables or connecting to cables
• • • •
Easy to install by hand Snap-on locking mechanism Waterproof according to IP 67 UV resistant
Housing Material
PA
Sealing Material
Silicone
Tightening Torque Gland
3Nm
Operating Temperature
-40°C~+70°C
Mating Cycles
>25
Suitable Cable Diameters
D4.5-D9
Pulling Axial
>150N
Ordering Information Part Number
Description
98Z105-S00 98Z105-S05
84
98Z105-S00/53
RFE - Protection cap plug
98Z105-S04
RFE - Coupler kit for RFE to RFE connection with LCD
98Z105-S90-XXX
RFE – Extension tube
R99220107
RFE - Protection cap plug (P)
Rosenberger Cable Systems Rosenberger Cable Systems develops, manufactures and supplies various outdoor, indoor and universal fiber optic cables for telecommunication industry, IT data center network, enterprise cabling network as well as many specialized cables for harsh environment applications. Rosenberger has supported remote radio Fiber-To-The-Antenna technologies by developing many cables with the most stringent specifications which are collaborated with world-leading network system vendors.
85
Quality and Environment A wide range of Rosenberger fiber optic cables are designed and manufactured with performance and future proofing in mind. Bandwidth and Attenuation are the key specification areas that ensure your fiber investment will stand the test of time. Internationally recognized standards have defined today’s level of performance. Rosenberger has selected a level of Attenuation and Bandwidth exceeds this level of performance for no significant cost penalty. It is vital that any investment in a fiber networking strategy provides long-term performance and reliability for these evolving international standards which will continue to advance and develop. Rosenberger fiber optic cables provide this long-term support when installed and used in well designed systems. Rosenberger has ensured the performance and reliability by specifying key optical attributes in the cable design and manufacturing. • Attenuation • Bandwidth • Fiber Geometry • Proof Test
Cable Standard Rosenberger fiber optic cable complies with one or several of the following international standards. • DIN VDE 0888
• ITU-T G.651 to G.657
• DIN VDE 0472
• TIA-EIA 598-B
• IEC 60793
• Telcordia GR-20
• IEC 60794
• Telcordia GR-409
• IEC 60332-1/3
Pictograph
Flame-Retardant The outer sheath of the cable is self-extinguishing and not fire conductive.
UV-Resistant The outer jacket of the cable is good performance on UVresistant
Rodent- Retardant The cable is protested against damage from the rodent.
86
UL Certification
Waterproof
The cable is UL certification and applying with OFNR or OFNP grade
Water in the core can not spread in the longitudinal and transverse direction
Enhanced Rodent- Retardant
RoHS-Compliant
The cable is protested against serious damage from the rodent
The cable is RoHS compliant according to 2011/65/EU (RoHS) and 2012/19/EU (WEEE)
Cable Jacket Material Designation
Polyolefine Flame Retardant
Polyvinyl Chloride
Polyethylene
Polyurethane Flame Retardant
Polyamide
Abbreviation
LSZH
PVC
PE
TPU/PR
PA(Nylon)
Combustion Properties Halogen Free
Yes
No
Yes
Yes
Yes
Flame Retardant
Yes
Yes
No
Yes
No
Smoke Emission
Low
Strong
Medium
Medium
Strong
Corrosive Fumes
Low
High
No
Low
No
Low
Medium
Good
Good
Good
Flexibility
High
High
Low
High
Low
Hardness
Medium
Soft
Hard
Soft
Hard
Oil/Fuel
Good
Good
Good
Satisfactory
Good
Water
Good
Good
Very Good
Good
Satisfactory
Weathering
Good
Good
Very Good
Good
Good
Mechanical Properties Abrasion Resistance
Resistance Against
• Information given in the table is based on plastic materials used for cable jackets. Properties and resistance for cables can not bederived from it. • The resistance against oil/fuel is meant as decision guidance to the best of our today’s knowledge. It is based on typical values. The resistance of cables has to be verified due to the wide variety of oils and fuels. • The resistance against weathering is same as the UV resistance and it highly depends on the color of jacket material used.
Test Procedure Tensile Performance • Standard: IEC 60794-1-2 E1 • Object: Detect the attenuation behavior and/or fiber elongation strain as a function of the load on the cable when occur during installation. Meanwhile the tension applied shall be within the maximum allowable tensile force. • Requirement: the result data shall not exceed the values given in the relevant detail specification. Abrasion • Standard: IEC 60794-1-2 E2 • Object: Determines the ability of the cable sheath to resist abrasion and the ability of cable markings to resist abrasion. • Requirement: No perforation of the sheath and optical continuity shall be maintained andthe marking shall be legible after performing the number of cycles specified in the detail specification.
87
Crush Resistance • Standard: IEC 60794-1-2 E3 • Object: Determines the ability of the cable to withstand crushing and detect the influence of the constant load on the attenuation. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including the degradation transmission or physical damage to the cable. Impact Performance • Standard: IEC 60794-1-2 E4 • Object: Determines the ability of the cable to withstand repeated impacts on the attenuation and it simulates the dropping heavy objects such as stones and tools when on operation. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including the degradation transmission or physical damage to the cable. Repeated Bending • Standard: IEC 60794-1-2 E6 • Object: Determines the ability of the cable to withstand repeated bending under tension load and the two extreme positions make an angle of 90 degree on both sides of the vertical. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including the degradation transmission or physical damage to the cable Torsion • Standard: IEC 60794-1-2 E7 • Object: Detects the ability of the cable to withstand the mechanical twisting and measures any variation in the optical transmission when the cable is subjected to torsional forces external to the cable jacket and evaluates the possibility of physical damage. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket or components Flexing Performance • Standard: IEC 60794-1-2 E8 • Object: Determines the ability of the cable to withstand repeated flexing, for example elevator cable and measures any variation in the optical transmission when the cable is on repeated flexing state and evaluates the possibility of physical damage. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket. Temperature Cycling • Standard: IEC 60794-1-2 F1 • Object: Determines the stability behavior of the attenuation of optical cables when the temperature changes. It is generally the result of buckling or tensioning of fibers resulting from differences between their thermal expansion coefficient and the coefficients of strength and jacket members. • Requirement: the result data shall not exceed the values given in the relevant detail specification and no typical failure modes including loss of optical continuity or physical damage to the jacket Water Penetration
88
• Standard: IEC 60794-1-2 F5A/F5B • Object: Applies to the continuously water-blocked cables and determines the ability of a cable to block water migration along a specified length and evaluates the resistance ability to the water and humidity. • Requirement: No water shall be detected at the unsealed end of the sample cable and thetime and dispersal of the water within the sample are the determining test criteria. Vertical Flame Propagation for a Single Cable • Standard: IEC 60332-1 • Object: Evaluates the flame propagation on the single cable, which is for communication, installed on the surface of walls inside buildings under the fire condition. • Requirement: 60mm length sample cable is mounted vertically and the flame must extinguish itself in relevant time and the fire damage must not reach the upper end of the sample cable. Vertical Flame Propagation for the Bundle Cables • Standard: IEC 60332-3 • Object: Evaluates the flame propagation on the bundle cables, which are depend on the volume of flammable material, fixed on a 3.5m long ladder and flame is applied at the base during 20 minutes. • Requirement: the height of fire damage must not exceed 2.5m and cables have an improved characteristics regarding fire propagation when it pass the test. Smoke Emission • Standard: IEC 61034 • Object: The measurement of smoke density is an important aspect in the evaluation of the burning performance of cables as it is related to the evacuation of persons and accessibility for fire-fighting. In a defined test environment the cable is exposed to an open fire of burning alcohol and it allows a statement of the expected line-of-sight obstruction in case of fire. • Requirement: the result data shall not exceed the values given in the relevant detail specification. Corrosive Fire Gases and Free of Halogen • Standard: IEC 60754-1/60754-2 • Object: Determines the volume of the corrosive fire gas and the halogen gas emission, which are washed out when the flammable materials are combusted at over 900 degree. The corrosiveness is determined by means of ph-values and electric conductivity. Halogen materials can release a considerable quantity of corrosive gases, which can cause consequential damage to the surrounding area as well as respiratory problems. • Requirement: the result data shall not exceed the values given in the relevant detail specification.
89
Buffered Fiber
Description Buffered fiber is made of bare fiber, fiber coating and buffer material. It is usually used for fiber optic link interconnection by terminating with fiber optic connectors.
Feature and Benefit • • • • •
Tight buffer, semi-tight buffer or loose buffer 0.6mm or 0.9mm diameter Buffer material options PVC, Hytrel, LSZH, Nylon All fiber type options Low attenuation
Specification Profile/Outline
Core Cladding Coating Buffer
Construction/Material Fiber Type
250μm or 500μm optical fiber
Fiber Color
Nature or other standard color
Buffer Material
PVC or LSZH or other specified
Buffer Color
White or other color specified available
Temperature Range
90
Transport and Storage Temperature
-30℃ ~ +65℃
Installation Temperature
-20℃~ +50℃
Operation Temperature
-30℃ ~ +65℃
Mechanical Properties Fiber Count
Nominal Buffer Diameter (mm)
Nominal Cable Weight (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Strip Length In One Piece Min.(mm)
Min. Bend Radius Static/Dynamic (mm)
0.6/0.9
0.9
3/6
100/500
30
30/50
1
Cable Transmission Performance Fiber Symbol Fiber Type Wavelength (nm) Attenuation (dB/Km)
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
≤0.36
≤0.36
≤0.22
≤0.22
≤0.25
≤3.2
≤1.0
≤2.7
≤1.0
≤2.7
≤1.0
Ordering Information
RB□□ - □□ □□ - □ □ - □□□□□ 1
2
3
1 Product Type RB01 = Tight Buffer RB02 = Semi-Tight Buffer RB03 = Loose Buffer
2 Jacket Color YL = Yellow OR = Orange BL = Blue AQ = Aqua GR = Green
3 Jacket Material 02 = LSZH 04 = PVC
05 = PVC 09 = Nylon
4
5
6
4 Fiber Buffer Diameter 6 = 600 μm 9 = 900 μm
5 Fiber Buffer Type T = Tight Buffer S = Semi-Tight Buffer L = Loose Buffer
6 Fiber Symbol G652D = Fiber G.652D OM3 = Fiber OM3 OM4 = Fiber OM4
91
Simplex Fiber Optic Cable
Description Simplex fiber optic cable is made of buffered fiber, strength member and jacket material. It is usually used for fiber optic link interconnection and patching by terminating with fiber optic connectors.
Feature and Benefit • 1.6-3.0mm diameter • Aramid yarn high strength material • All fiber type options • Low attenuation • Jacket color options • OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2
Specification Profile/Outline Core Cladding Coating Buffer Aramid Yarns Strength Member Jacket
Construction/Material Buffer
Tight buffer or semi-tight buffer
Buffer Color
White or other color specified
Strength Member
Aramid yarn (Kevlar)
Cable Jacket
PVC or LSZH or other specified Yellow for Singlemode
Color of Jacket
Orange for Multimode Aqua for OM3 Other color specified available
Temperature Range
92
Transport and Storage Temperature
-20℃ ~ +70℃
Installation Temperature
-5℃ ~ +50℃
Operation Temperature
-20℃ ~ +70℃
Mechanical Properties Nominal Fiber Cable Diameter Count (mm)
Nominal Buffer Diameter (Kg/Km)
Nominal Cable Weight (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
1
1.6
0.6
2.9
60/120
100/500
30/50
1
1.8
0.9
3.7
60/120
100/500
30/50
1
2.0
0.9
5.0
60/120
100/500
30/50
1
2.4
0.9
5.7
80/150
100/500
30/50
1
2.8
0.9
7.9
80/150
100/500
30/50
1
3.0
0.9
8.1
80/150
100/500
30/50
Cable Transmission Performance Fiber Symbol
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Fiber Type Wavelength (nm) Attenuation (dB/Km)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
Ordering Information
RI07- □□ □□ □□ - □□ - 0 0 1 - □□□□□ 1
2
3
4
5
6
7
8 5 Fiber Buffer Diameter
1 Product Type
6 = 600 um 9 = 900 um
RI07 = Product No.
6 Fiber Buffer Type
2 Jacket Color YL = Yellow OR = Orange BL = Blue AQ = Aqua GR = Green
T = Tight Buffer S = Semi-Tight Buffer L = Loose Buffer
7 Fiber Count
3 Jacket Material
001 = 1 Core
02 = LSZH 04 = PVC 05 = PVC
8 Fiber Symbol
4 Cable Diameter 16 = 1.6mm
24 = 2.4mm
18 = 1.8mm
28 = 2.8mm
G652D = Fiber G.652D OM3 = Fiber OM3
20 = 2.0mm
30 = 3.0mm
OM4 = Fiber OM4
93
Duplex Fiber Optic Cable
Description Duplex fiber optic cable is made of two buffered fibers, strength member and jacket material and in a figure of eight. It is usually used for fiber optic link interconnection and cross-connect patching by terminating with fiber optic connectors.
Feature and Benefit • Single cable diameter 1.6-3.0mm • Aramid yarn high strength material • All fiber type options • Low attenuation performance • Jacket color options • OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2
Specification Profile/Outline
Core Cladding Coating Buffer Aramid Yarns Strength Member Jacket
Construction/Material Buffer
Tight buffer or semi-tight buffer
Buffer Color
White/Blue or Blue/Orange Other color specified available
Strength Member
Aramid yarn (Kevlar)
Cable Jacket
PVC or LSZH or other specified Yellow for Singlemode
Color of Jacket
Orange for Multimode Aqua for OM3 Other color specified available
Temperature Range
94
Transport and Storage Temperature
-20℃ ~ +70℃
Installation Temperature
-5℃ ~ +50℃
Operation Temperature
-20℃ ~ +70℃
Mechanical Properties Nominal Cable Diameter (mm)
Nominal Buffer Diameter (mm)
Nominal Cable Weight (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
2
1.6*3.3
0.6
5.8
60/120
100/500
30/60
2
1.8*3.7
0.9
7.4
60/120
100/500
30/60
2
2.0*4.1
0.9
10.0
60/120
100/500
30/60
2
2.4*4.9
0.9
11.4
80/150
100/500
30/60
2
2.8*5.7
0.9
15.8
80/150
100/500
30/60
2
3.0*6.1
0.9
16.2
80/150
100/500
30/60
Fiber Count
Cable Transmission Performance Fiber Symbol Fiber Type Wavelength (nm) Attenuation (dB/Km)
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
Ordering Information
RI08- □□ □□ □□ - □□ - 0 0 2 - □□□□□ 1
2
3
4
5
6
7
8 5 Fiber Buffer Diameter
1 Product Type
6 = 600 μm 9 = 900 μm
RI08 = Product No.
6 Fiber Buffer Type
2 Jacket Color YL = Yellow OR = Orange BL = Blue AQ = Aqua GR = Green
T = Tight Buffer S = Semi-Tight Buffer L = Loose Buffer
7 Fiber Count
3 Jacket Material
002 = 2 Cores
02 = LSZH 04 = PVC 05 = PVC
8 Fiber Symbol
4 Cable Diameter 16 = 1.6mm
24 = 2.4mm
18 = 1.8mm
28 = 2.8mm
G652D = Fiber G.652D OM3 = Fiber OM3
20 = 2.0mm
30 = 3.0mm
OM4 = Fiber OM4
95
Distribution Fiber Optic Cable
Description Distribution fiber optic cable is made of multiple buffered fibers, strength member and jacket material as well as a ripcord as option. It is usually used for fiber optic link interconnection, main trunk and building riser distribution with or without fiber optic connector terminated.
Feature and Benefit • Up to 24 fibers or more on request • Aramid yarn high strength material • All fiber type options • Low attenuation performance • Jacket color options • OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2
Specification Profile/Outline
Fiber Buffer Aramid Yarns Strength Member Ripcord (option) Jacket
Construction/Material Buffer
Tight buffer or semi-tight buffer
Buffer Color
Per TIA 598-B
Strength Member
Aramid yarn (Kevlar)
Ripcord
Easily ripping the cable jacket
Cable Jacket
PVC or LSZH or other specified
Color of Jacket
Yellow for Singlemode Orange for Multimode Aqua for OM3 Other color specified available
Temperature Range
96
Transport and Storage Temperature
-20℃ ~ +70℃
Installation Temperature
-5℃ ~ +50℃
Operation Temperature
-20℃ ~ +70℃
Mechanical Properties Fiber Count
Subunit Count
Nominal Cable Diameter (mm)
Nominal Cable Weight(LSZH/PVC) (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
1
4.0
14/13
130/440
200/1000
40/80
2 4
1
4.8
18/16
130/440
200/1000
48/96
6
1
5.1
23/20
130/440
200/1000
51/102
8
1
5.6
31/27
130/440
200/1000
55/110
10
1
5.8
34/29
130/440
200/1000
58/116
12
1
6.2
36/32
130/440
200/1000
62/124
18
1
8.1
57/53
130/440
200/1000
81/162
24
1
8.1
57/53
130/440
200/1000
81/162
Cable Transmission Performance Fiber Symbol
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Fiber Type Wavelength (nm) Attenuation (dB/Km)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
Ordering Information
RI12- □□ □□ - □□ - □□□ - □□□□□ 1
2
3
1 Product Type RI12 = Product code
2 Jacket Color YL = Yellow OR = Orange BL = Blue AQ = Aqua GR = Green
3 Jacket Material 02 = LSZH 04 = PVC 05 = PVC
4 5
6
7 4 Fiber Buffer Diameter 6 = 600 μm 9 = 900 μm
5 Fiber Buffer Type T = Tight Buffer S = Semi-Tight Buffer L = Loose Buffer
6 Fiber Count 004 = 4 Cores ... 024 = 24 Cores
7 Fiber Symbol G652D = Fiber G.652D OM3 = Fiber OM3 OM4 = Fiber OM4
97
Breakout fiber Optic Cable
Description Breakout fiber optic cable is made of multiple 2.0mm simplex cables, dielectric central strength member, wrap tape, jacket material and a ripcord. It is usually used for fiber optic link interconnection, main trunk and building riser distribution by terminating with fiber optic connectors.
Feature and Benefit • Up to 24 fibers or more on request • Aramid yarn high strength material for subunits • All fiber type options • Low attenuation performance
Specification Profile/Outline
• Jacket color options • OFNR per UL-1666 and OFNP per UL-910 • LSZH per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2
Fiber 900um Buffer Aramid Yarns Strength Member 2.0mm Fiber Subunit FRP Wrap Tape (option) Ripcord (option) Jacket
Construction/Material Buffer
900μm tight buffer or semi-tight buffer
Buffer Color
White or other color specified
Strength Member
Aramid yarn (Kevlar)
Subunit Diameter
2.0mm
Subunit Jacket
PVC or LSZH jacket
Central Member
FRP as the dielectric member for central strength element with no bonding
Ripcord
Easily ripping the cable jacket
Cable Jacket
PVC or LSZH or other specified
Color of Jacket and Subunit Jacket
Yellow for Singlemode Orange for Multimode Aqua for OM3 Other color specified available
Temperature Range
98
Transport and Storage Temperature
-20℃ ~ +70℃
Installation Temperature
-5℃ ~ +50℃
Operation Temperature
-20℃ ~ +70℃
Mechanical Properties Nominal Cable Diameter (mm)
Nominal Cable Weight(LSZH/PVC) (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
2
7.4
56/50
250/500
300/1000
74/148
4
7.4
56/50
250/500
300/1000
74/148
6
8.4
74/66
250/500
300/1000
84/168
Fiber Count
8
9.8
101/91
500/1000
300/1000
98/196
12
12.0
134/121
500/1000
300/1000
120/240
16
12.4
155/140
500/1000
300/1000
124/248
24
14.4
201/181
500/1000
300/1000
144/288
Cable Transmission Performance Fiber Symbol Fiber Type Wavelength (nm) Attenuation (dB/Km)
G652D/G657A1/A2/B2/B3 B1.3/B6a.1/2 B6b.2/3
G655C/D/E B4
OM1 A1b
OM2/OM2+ A1a/A1a.1
OM3/OM4 A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
Ordering Information
RI14- □□ □□ □□ - □□ - □□□ - □□□□□ 1
2
3
1 Product Type RI14 = Product No.
2 Jacket Color YL = Yellow OR = Orange BL = Blue AQ = Aqua GR = Green
3 Jacket Material 02 = LSZH 04 = PVC 05 = PVC
4 Cable Diameter 20 = 2.0mm
4
5
6
7
8 5 Fiber Buffer Diameter 6 = 600 μm 9 = 900 μm
6 Fiber Buffer Type T = Tight Buffer S = Semi-Tight Buffer L = Loose Buffer
7 Fiber Count 002 = 2 Cores ... 024 = 24 Cores
8 Fiber Symbol G652D = Fiber G.652D OM3 = Fiber OM3 OM4 = Fiber OM4
99
Distribution Fiber Optic Cable for FTTA
Description This specialized distribution fiber optic cable is designed for harsh environment application such as high performance fiber-to-theantenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.
Feature and Benefit • Up to 4 fibers or more on request • All fiber type options • Low attenuation performance • Compact cable size
• Water proof design • Support rigorous temperature range • LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2 • OFNR (UL-1666) approval option
Specification Profile/Outline
Fiber Tight Buffer Strength Member Jacket
Construction/Material Buffer Type
600μm/900μm tight buffer
Buffer Color
2 Cores: Blue/Red 4 Cores: Blue/Red/Green/Yellow
Strength Member
Aramid yarn (Kevlar) or Glass yarn
Cable Jacket
LSZH, PVC or other specified
Color of Jacket
Black (UV resistant)
Temperature Range Transport and Storage
-40℃ ~ +85℃ (+95℃)
Installation
-20℃ ~ +60℃
Operation
-40℃ ~ +85℃
Mechanical Properties
2
Nominal Cable Diameter (mm) 4.8
Nominal Cable Weight (Kg/Km) 18
Tensile Strength Long-term/Short-term (N) 300/450
Crush Resistance Long-term/Short-term (N/10cm) 1000/2200
Min. Bend Radius Static/Dynamic (mm) 48/96
4
5.2
18
300/450
1000/2200
48/96
Fiber Count
Cable Transmission Performance Fiber Symbol Fiber Type
100
G652D/G657A1/A2/B2/B3
G655C/D/E
B1.3/B6a.1/2 B6b.2/3
OM1
B4
OM2/OM2+
A1b
A1a/A1a.1
OM3/OM4 A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
Armored Fiber Optic Cable for FTTA
Description This type of armored fiber optic cable is designed for harsh environment application such as high performance fiber-to-the-antenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, spiral stainless steel amore tube, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance as well as rodent protection capability.
Feature and Benefit • Up to 4 fibers or more on request • All fiber type options • Low attenuation performance • Compact cable size • Water proof design
• Support rigorous temperature range • Rodent protection and monkey bite • LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2 • OFNR (UL-1666) approval option
Specification
Fiber
Profile/Outline
Tight Buffer Spiral Amored Tube Strength Member Jacket
Construction/Material Buffer Type
600μm/900μm tight buffer
Buffer Color
Singlemode: Red/Blue Multimode: Orange/White
Armored
Spiral stainless tube
Strength Member
Aramid yarn (Kevlar) or Glass yarn
Cable Jacket
LSZH, PVC or other specified
Color of Jacket
Black (UV resistant)
Temperature Range Transport and Storage Temperature
-40℃ ~ +85℃
Installation Temperature
-20℃ ~ +65℃
Operation Temperature
-40℃ ~ +85℃
Mechanical Properties Fiber Count
Nominal Cable Diameter (mm)
Nominal Cable Weight (Kg/Km)
Tensile Strength Longterm/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
4.8
38.5
300/450
1000/3000
48/96
2
Cable Transmission Performance Fiber Symbol Fiber Type
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
101
Breakout Fiber Optic Cable for FTTA
Description This type of specialized breakout fiber optic cable is designed for harsh environment application such as high performance fiber-to-theantenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple 2.0mm subunits, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.
Feature and Benefit • Up to 4 fibers or more on request • All fiber type options • Low attenuation performance • Water proof design
• Support rigorous temperature range • LSZH-rated per IEC 60332-1/3, IEC 60754-2 and IEC 61034-2 • OFNR (UL-1666) approval option Fiber
Specification
Tight Buffer
Profile/Outline
Aramid Yarns Strength Member Subunit Cable Jacket Filler Jacket
Jacket
Construction/Material Buffer Type Buffer Color Sub-unit Jacket Sub-unit Jacket Color (2-core) Sub-unit Jacket Diameter Strength Member Cable Jacket Color of Jacket Temperature Range Transport and Storage Temperature Installation Temperature Operation Temperature
600μm/900μm tight buffer White or other specified LSZH Singlemode: Yellow/Blue Multimode: Orange/Grey 2.0mm Aramid yarn (Kevlar) LSZH Black (UV resistant) -40℃ ~ +80℃ -20℃ ~ +60℃ -40℃ ~ +80℃
Mechanical Properties Fiber Count
Nominal Cable Diameter (mm)
Fiber Structure (mm)
Nominal Cable Weight (Kg/Km)
Tensile Strength Long-term/Short-term (N)
Crush Resistance Long-term/Short-term (N/10cm)
Min. Bend Radius Static/Dynamic (mm)
7.0
0.6/0.9
38
200/400
1000/2200
70/140
2
Cable Transmission Performance Fiber Symbol Fiber Type
102
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
≤0.45
≤0.45
≤0.35
≤0.35
≤0.40
≤3.5
≤1.5
≤3.2
≤1.2
≤3.0
≤1.0
103
www.rosenberger.com www.rosenbergerap.com
Rosenberger Hochfrequenzetechnik GmbH & Co. KG P. O. BOX 1260 D-84526 Tittmoning Tel: +49-86 84-18-0 I E-mail: [email protected] Fax: +49-86 84-18-499 I Web: www.rosenberger.com
No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China 101300 Tel : (+86 10) 80481995 I E-mail: [email protected] Fax : (+86 10) 80497052 I Web: www.rosenbergerap.com Rosenberger (Shanghai) Technology Co., Ltd. B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park, Shanghai, China 201201 Tel : (+86 21) 58995997 I E-mail: [email protected] Fax : (+86 21) 58995994 I Web: www.rosenbergerap.com Rosenberger Technology (Kunshan) Co., Ltd. No.6, Shenan Road, Dianshanhu Town, Kunshan, Jiangsu, China 215345 Tel : (+86 512) 86896789 I E-mail: [email protected] Fax : (+86 512) 86890666 I Web: www.rosenbergerap.com
8
4