Rapid Sand Filter Design Design a rapid sand filter to treat 10 million litres of raw water per day allowing 0.5% of filtered water for backwashing. Half hour per day is used for bakwashing. Assume necessary data.
Problem:
6
=10.05 x 24 x 10 Solution: Total filtered water =10.05
=0.42766 Ml / h
24 x 23.5 2
Let the rate of filtration be 5000 l / h / m of bed. 6
2
Area of filter =10.05 = 10.05 x 10 x 1 =85.5 m 23.5 5000
2
P rovide rovide two two units. units. Each E ach bed area 85.5/2 85.5/2 =42.77. L/B =1.3; 1.3B =42.77 B =5.75 m ; L =5.75 x 1.3 =7.5 m Assume depth of sand =50 to 75 cm. Underdrainage system: Total Total area area of hole holes s =0.2 =0.2 to 0.5% 0.5% of bed bed area area.. 2
Assum Ass ume e 0.2% of bed bed area = 0.2 x 42.77 =0.086 m 100 100 Area of lateral =2 (Area of holes of lateral) Area of manifold =2 (Area of laterals) laterals)
2
So, area of manifold =4 x area of holes =4 x 0.086 =0.344 =0.35 m . 1/2 1/2
Diameter of manifold =(4 x 0.35 /p)
=66 cm
Assum Ass ume e c/c of lateral lateral =30 = 30 cm. Total numbers numbers =7.5/ = 7.5/ 0.3 =25 = 25 on either either side. Length of lateral =5.75/2 - 0.66/2 =2.545 m. C.S. area of lateral =2 x area of perforations per lateral. Take dia of holes =13 mm Number of holes:
2
4
2
n p (1.3) =0.086 x 10 =860 cm 4
n = 4 x 860 =648, say 650 p (1.3)
2
Number of holes per lateral =650/50 =13 2
2
Area of perforations per lateral =13 x p (1.3) /4 =17.24 cm Spacing of holes =2.545/13 =19.5 cm.
2
C.S. area of lateral =2 x area of perforations per lateral =2 x 17.24 =34.5 cm . Diameter of lateral =(4 x 34.5/p)
1/2 1/2
=6.63 cm
Check: Length of lateral <60 d =60 x 6.63 =3.98 m. l =2.545 m (Hence acceptable). Rising washwater velocity in bed =50 cm/min. 3
Washwater discharge per bed =(0.5/60) x 5.75 x 7.5 =0.36 m /s. 4
Velocity of flow through lateral = 0.36 = 0.36 x 10 =2.08 m/s (ok) Total lateral area 50 x 34.5 Manifold velocity = 0.36 0.345
=1.04 m/s <2.25 m/s (ok)
Washwater gutter 3
Discharge of washwater per bed =0.36 m /s. Size of bed =7.5 x 5.75 m. Assume 3 troughs running lengthwise at 5.75/3 =1.9 m c/c. 3
Discharge of each trough =Q/3 =0.36/3 =0.12 m /s. Q =1.71 x b x h
3/2
Assume b =0.3 m 3/2
h
= 0.12 =0.234 1.71 x 0.3
h =0.378 m =37.8 cm =40 cm =40 +(free board) 5 cm =45 cm; slope 1 in 40 Clear water reservoir for backwashing 3
For 4 h filter capacity, Capacity of tank =4 x 5000 x 7.5 x 5.75 x 2 =1725 m 1000 2
Assume depth d =5 m. Surface area =1725/5 =345 m 2
L/B =2; 2B =345; B =13 m & L =26 m. Dia of inlet pipe coming from two filter =50 cm. Velocity <0.6 m/s. Diameter of washwater pipe to overhead tank =67.5 cm. 2
Air compressor unit =1000 l of air/ min/ m bed area. 3
For 5 min, air required =1000 x 5 x 7.5 x 5.77 x 2 =4.32 m of air.