Entre las causa que explican la continuidad de la violencia en Colombia se encuentra la modernización de la nación acompañada de un desarrollo desigual. Este documento explora dicho fenómeno…Descripción completa
Full description
Baron's TOEFL ReadingDeskripsi lengkap
Baron's TOEFL Reading
luDescripción completa
Effects of text messaging to the spelling ability of students.
Practice for students
Conceptos basicos para diseño de jardines
DRY EXCAVATION USING A TIE BACK WALL (LESSON 4).
Colreg question part 1Full description
Children activityFull description
Get ready to learn the little known secrets that airlines use to weed out 90% of the applications they receive each month - the unspoken hiring practices that stop even the most confident applicant...
EN 12464-1:2002 (E)
Table 5.7 — Health care premises 7.1
Rooms for general use
Ref. Ref. no. no.
Type Type of inte interi rior or,, tas task k or or act activ ivity ity
m
UGRL -
lx
Ra -
Remarks All illuminances at floor level.
7 .1 . 1
W aiting rooms
2 00
22
80
7 .1 . 2
Corridors: during the day
200
22
80
7 .1 . 3
Corridors: during the night
50
22
80
7 .1 . 4
Day rooms
2 00
22
80
7.2
Staff rooms
Ref. Ref. no. no.
Type Type of inte interi rior or,, tas task k or or act activ ivity ity
UGRL -
Ra -
m
lx 7 .2 . 1
Staff office
500
19
80
7 .2 . 2
Staff rooms
300
19
80
7.3
Wards, maternity wards
Ref. Ref. no. no.
Type Type of inte interi rior or,, tas task k or or act activ ivity ity
UGRL -
Ra -
m
lx
Remarks
Remarks Prevent too high luminances in the patients' field of view.
7 .3 . 1
General lighting
100
19
80
7 .3 . 2
Reading lighting
3 00
19
80
7 .3 . 3
Simple examinations
30 0
19
80
7 .3 . 4
Examination and treatment
10 00
19
90
7 .3 . 5
Night lighting, observation lighting
5
-
80
7 .3 . 6
Bathrooms and toilets for patients
20 0
22
80
7.4
Examination rooms (general)
Ref. Ref. no. no.
Type Type of inte interi rior or,, tas task k or or act activ ivity ity
UGRL -
Ra -
500
19
90
10 00
19
90
m
lx 7 .4 . 1
General lighting
7 .4 . 2
Examination and treatment
Illuminance at floor level.
Remarks
27
EN 12464-1:2002 (E)
Table 5.7 — Health care premises (continued) 7.5
Eye examination rooms
Ref. no.
Type of interior, task or activity
m
Ra -
300
19
80
1000
-
90
500
16
90
UGRL -
Ra -
19
80
-
90
UGRL -
Ra -
300
19
80
50
19
80
DSE-work: see 4.11.
UGRL -
Ra -
Remarks
300
19
80
1000
19
80
UGRL -
Ra -
Remarks Lighting should be controllable.
lx 7.5.1
General lighting
7.5.2
Examination of the outer eye
7.5.3
Reading and colour vision tests with vision charts
7.6
Ear examination rooms
Ref. no.
Type of interior, task or activity
m
lx 7.6.1
General lighting
300
7.6.2
Ear examination
1000
7.7
Scanner rooms
Ref. no.
Type of interior, task or activity
m
lx 7.7.1
General lighting
7.7.2
Scanners with image enhancers and television systems