OPERATIONS PA-F PA -FDD-ID ID FA FA NS
Tanjung Jati B Training
PA-FD-ID Fans Location
PA FA NS
FD FANS
ID FA NS Tanjung Jati B Training
PA-FD-ID Fans Function
The fans serve serve to provid pro vide e the followi foll owing ng re r egarding The operation operati ons s of o f the t he Boiler, Boi ler, ES ESP & FGD FGD Sys ystems tems… … FD FANS:
Combus ombustion tion Air A ir for fo r the Burners
ID FANS:
Remo move ve Flu Flue e Ga Gas fro f rom m the t he Boiler Boi ler & ESP and force fo rce the fl flue ue ga gas s throu th rough gh the th e FGD Sys System tem to t o the t he Stack Stack
PA FANS:
Prov rovide ide air air for f or the t he opera operati tion on of the Pulv ulve eri riz zers and tr tra ansp nsport ort of pul pulveriz verize ed coal to the th e Bur Burne ners rs Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD) Induced Draft (ID) Primary Air (PA)
Tanjung Jati B Training
FD Fans Each FD Fan has a single inlet and provide 50% of the total air requirement at Boiler Maximum Continuous Rating firing Bengalon Coal at 1% sulfur. The FD Fans are the Axial type versus the Centrifugal type PA and ID Fans. Air flow through the fan is controlled by the Variable Pitch Blades.
Tanjung Jati B Training
FD Fans Axial Design
OUTLET AIR
AIR FL OW
BLADES STRAIGHTENING VANES
INLET BOX MOTOR
DIFFUSER
LUBE A ND/OR HYDRAULIC UNIT
Tanjung Jati B Training
FD Fans Secondary Air System Inlet Silencer FD Fan
Air Foil “ A”
Air Heater
SCAH Screen
Bur ner Level Windbox (typical)
Hot Crossover Duct
Air Heater
N Air Foil “ B”
SCAH
FD Fan
Tanjung Jati B Training
ID Fans Fan Bearings The ID Fans have sleeve-type bearings which require continuous water flow for cooling. Water is supplied by the Closed Circuit Cooling Water (CCCW) system. The bearing are also equipped with a oil level site gauge. If the oil appears cloudy or frothy, most likely cooling water has entered the oil cavity and has contaminated.
Tanjung Jati B Training
FD Fans Some Components and Terms to remember… Variable Pitch Blades Hydraulic-Lube Unit Fan Stall
Tanjung Jati B Training
FD Fans Variable Pitch Blades
Variable Pitch Blades, internal to the Fan Housing are used to control air flow through the fan. A stand alone Hydraulic Oil Unit provides the necessary oil pressure to adjust the pitch of the Blades.
Tanjung Jati B Training
FD Fans Hydraulic Unit
The Hydraulic Unit serves two functions… Adjust the pitch of the Blades Provide Lube Oil for the Fan Bearings
Tanjung Jati B Training
FD Fans Hydraulic Unit
The Hydraulic Oil Unit consists of the following… Local Control Cabinet Two (2) motor-driven oil pumps Oil Heater Oil Cooler Oil Sump Filters Instrumentation (Flow switch, Level switch…)
Tanjung Jati B Training
FD Fans Hydraulic Unit
The Control Cabinet has the following features… Indication Lamps Oil Pump Status Oil Heater Status High/Low Oil Temperature Low Oil Level Low Oil Flow Low Oil Pressure
Tanjung Jati B Training
FD Fans Hydraulic Unit
…The Control Cabinet has the following features… Buttons & Switches Oil Pump Select Oil Pump Start Oil Pump Stop Oil Pump Hand/Off/Auto (x2) Alarm Reset
Tanjung Jati B Training
FD Fans Hydraulic Unit
The Oil Pumps are interlocked such that a significant drop in oil pressure from the operating pump will start the stand-by pump.
Tanjung Jati B Training
FD Fans Hydraulic Unit CONTROL PANEL
OIL PUMPS
OIL SUMP
Tanjung Jati B Training
FD Fans Start-Up
Prior to starting an FD Fan, the Hydraulic Unit must be available and operating. If the Hydraulic Unit panel indicates any alarms, these should be investigated and cleared prior to starting the Fan. An Induced Draft Fan must be in service prior to starting an FD Fan.
Tanjung Jati B Training
FD Fans Automatic Operation
During automatic operation the FD Fan Inlet Vanes will control air pressure in the Secondary Hot Crossover Duct to the desired set point.
Tanjung Jati B Training
FD Fans Trip Interlocks
Fans will trip under the following conditions… Secondary Air Duct Pressure High-High High Fan Bearing Vibration High Fan Bearing Oil Temperature Furnace Pressure High-High Loss of Flow Path Loss of Breaker (power failure) High Motor Amps (time delay) Hydraulic Oil Unit Failure
Tanjung Jati B Training
FD Fans Shutdown
Prior to stopping the FD Fan, the fan’s loading should be reduced manually and slowly. This will allow the other operating FD Fan to maintain control of the Secondary Air Duct pressure.
Tanjung Jati B Training
FD Fans Stall
Fan stall is a condition where there is a sudden and significant drop in the differential pressure (air flow) between the fan inlet and outlet. A differential pressure transmitter is provided to monitor air flow conditions.
Tanjung Jati B Training
FD Fans Stall
Fan stall is a serious and potentially danger situation which is usually accompanied by vibration and increased noise. Fan blade failure can occur. When fan stall is suspected, the fan should be SHUT DOWN immediately.
Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD) Induced Draft (ID) Primary Air (PA)
Tanjung Jati B Training
ID Fans Description The Induced Draft (ID) Fans are single-speed, double-inlet, centrifugal-type fans. The ID Fans operate at a relatively low speed compared to the FD Fans and Primary Air Fans.
Tanjung Jati B Training
ID Fans Function The ID Fans remove flue gas from the Boiler and the Precipitator and force those flue gasses through the FGD System to the stack.
Tanjung Jati B Training
PA-FD-ID Fans Location
PA FANS
FD FANS
ID FANS Tanjung Jati B Training
ID Fans Operation
ID Fans, serve to control Furnace Draft Pressure during Unit operation. During start-up of the Boiler, the ID Fan Inlet vanes and Start-Up Damper work in unison to control the flow through the ID Fan.
Tanjung Jati B Training
ID Fans Flue Gas System Boiler Guillotine Isolation Damper with Seal Air Start-Up Control Damper
Man-Safe Double Dampers with Seal Air
Tri-Sector Ai r Heater s
Precipitators
ID Fans
To FGD
Tanjung Jati B Training
ID Fans Fan Bearings The ID Fan have sleeve-type bearings which require continuous water flow for cooling. Water is supplied by the Closed Circuit Cooling Water (CCCW) system. The bearing are also equipped with a oil level site gauge. If the oil appears cloudy or frothy, most likely cooling water has entered the oil cavity and has contaminated.
Tanjung Jati B Training
ID Fans Start-Up
Prior to starting an ID Fan, an operator should check the oil level in the bearing and be sure that the CCCW isolation valves are open. Be sure all housing doors are closed and an operator should be present when the fan is started.
Tanjung Jati B Training
ID Fans Start-Up When the ID Fan is commanded to start, the fan’s Outlet Isolation Guillotine Damper will close. Once the damper’s close limit switch is activated the fan will start. The isolation damper will open after a time delay. After the ID Fan is started, the operator will manually modulate both the FD & ID Fans to achieve the desired air flow and furnace pressure prior to putti ng control in automatic.
Tanjung Jati B Training
ID Fans Automatic Operation
The ID Fans inlet vanes modulate to control Furnace Pressure only. If two fans are running and one trips, the remaining ID fan will control Furnace Draft while the unit runs back or reduces load towards 50%.
Tanjung Jati B Training
ID Fans Automatic Operation
How does an operator know both fans are operating at the same load?... The motor running amps will be the same!
Tanjung Jati B Training
ID Fans Trip Interlocks
Fans will trip under the following conditions… High Fan Bearing Vibration High Fan Bearing Oil Temperature Furnace Pressure High-High Loss of Flow Path Loss of Breaker (power failure) High Motor Amps (time delay)
Tanjung Jati B Training
ID Fans Shutdown
Similar to the FD Fan, the inlet vane controls should be put into manual and the Inlet Vanes should be closed slowly. When the fan is at minimum loading, the fan can be stopped.
Tanjung Jati B Training
PA-FD-ID Fans
Forced Draft (FD) Induced Draft (ID) Primary Air (PA)
Tanjung Jati B Training
PA-FD-ID Fans Location
PA FANS
FD FANS
ID FANS Tanjung Jati B Training
Primary Air (PA) Fans Function Two (2) 60% capacity, single-speed, centrifugal-type primary air fans are needed for the following… Circulation of coal in the pulverizers Hot air to dry the coal Transport pulverized coal to the burners Primary air accounts for approximately 25% of the air flow required for combustions Tanjung Jati B Training
Primary Air Guillotine Isolation Damper
Air Measurement
Control Dampers
Cold Air Duct MILL A Hot Air Duct
Tri-Sector Air Heater Inlet Scr een and Silencer
MILL B
MILL C PA Fans MILL D
MILL E Isolation Dampers
MILL F To Seal Air Fans
Tanjung Jati B Training
PA Fans Fan Bearings The PA Fans have sleeve-type bearings which require continuous water flow for cooling. Water is supplied by the Closed Circuit Cooling Water (CCCW) system. The bearing are also equipped with a oil level site gauge. If the oil appears cloudy or frothy, most likely cooling water has entered the oil cavity and has contaminated.
Tanjung Jati B Training
PA Fans Fan Motors
The PA Fan Motors have oil-lubricated bearings which requires a stand alone lube oil skid. One lube oil skid supplies oil to both motors.
Tanjung Jati B Training
PA Fans Fan Motor Lube Oil Skid
The lube skid has very similar components to the FD Fan oil skid… Two (2) Oil Pumps Oil Sump Filters Air Cooler Oil Pressure & Temperature Switches Gauges Junction Box
Tanjung Jati B Training
PA Fans Start-Up
Prior to starting an PA Fan, an operator should check the oil level in the bearing and be sure that the CCCW isolation valves are open. Be sure all housing doors are closed and an operator should be present when the fan is started.
Tanjung Jati B Training
PA Fans Start-Up
Prior to starting an PA Fan, an operator should also check to be sure that the Motor Lube Oil Skid is started and functioning properly (no alarms
PA Fans Start-Up
Prior to starting a pulverizer, a PA must be started first. When the fan is commanded to start, the fan’s Outlet Isolations Damper will be commanded to close. once the Damper’s closed limit switch is activated, the PA Fan starts. After a specified time delay, the Outlet Isolation Damper opens.
Tanjung Jati B Training
PA Fans Automatic Operation
The loading of the PA Fans is controlled by variable Inlet Vanes. This is determined by the Primary Air Hot Crossover Duct Pressure Set Point. If two fans are in service and one trips, the Boiler load will runback to approximately 60% load.
Tanjung Jati B Training
PA Fans Trip Interlocks
Fans will trip under the following conditions… Boiler MFT (pulverizers tripped) High Fan Bearing Vibration High Fan Bearing Oil Temperature Loss of Flow Path Loss of Breaker (power failure) High Motor Amps (time delay)
Tanjung Jati B Training
PA Fans Shutdown
Similar to the other fans, the inlet vane controls should be put into manual and the Inlet Vanes should be closed slowly. When the fan is at minimum loading, the fan can be stopped.
Tanjung Jati B Training
PA Fans Shutdown
Once the last pulverizer has been shutdown, the Primary Air Fans can be stopped.
Tanjung Jati B Training
PA-FD-ID Fans General Start-Up Sequence
The start-up sequence for the fans is as follows. This assumes all fans are available… ID Fan A or ID Fan B FD Fan A FD Fan B ID Fan B ID Fan A FD Fan B FD Fan A PA Fans A/B (prior to starting a pulverizer)