OUTLINED SPECIFICATIONS PROJECT:
PROPOSED TWO- STOREY RESIDENCE W/ ATTIC AND DECK
LOCATION:
TUYO BALANGA CITY, BATAAN
OWNER:
ATTY & MRS. DENTE ILAYA
ITEM NO. I
II
III
PARTICULARS GENERAL REQUIREMENTS 1. Mobilization/Demobilization
SPECIFICATIONS Moving in of the necessary manpower, tools equipment at site for the start of construction & thereafter moving out of all these upon completion of the project.
2. Site Clearing
Clearing of the site from all unnecessary plants, garbage and other things that may hamper in the construction.
3. Staking & Layout
Construction of batter boards to establish the buildings line & grade.
4. Temporary Facilities
Construction of temporary fence enclosing the site, bunkhouse and toilet for all stayin workers, filed office for all concerned project personnel, bodega for storage of materials and provision of electrical & water connections all of which to be dismantled and removed from the site upon completion of the project.
EARTHWORKS 1. Excavation
All column footings & wall footings shall be excavated to the desired depth and all such structures shall in no case rest on fill.
2. Backfilling & Construction
Excavated soil shall be backfilled with thorough compaction upon concreting of footings and other sub- grade structures.
3. Earthfilling & Compaction
All area with elevated floor lines shall be filled with selected borrow fill materials and shall be thoroughly compacted layer by layer.
4. Gravel Filling & Compaction
Provision of 0.05 meter thick (min) gravel bedding with compaction as base for all footings & slab on fill.
5. Soil Treatment
Application of chlordance or equivalent soil poisoning material properly diluted with water poured into the ground surfaces here footings and slab on fill shall rest.
CONCRETE WORKS 1. Concrete
20.685 MPa (3000 psi) concrete strength at 28 days using jobstite mixed concrete for all footings, columns, beams, stair and suspended slab and 17.24 MPa (2500 psi) concrete strength for slab on fill.
IV
2. Steel Reinforcing Bars
275.8 MPa (44000 psi) tensile yield strength of deformed bars for 12 mmØ and above and 227.5 MPa (33000 psi) for 10 mmØ and below.
3. Formworks & Scaffoldings
Using 12mm thick form plywood applied with form oil at side in contact with concrete and for frame & scaffoldings using a combination of good lumber and coco lumber.
WALLS & WALL FINISHES 1. Exterior Walls
2. Interior Walls
3. Exterior & Interior Finishing of Wall Except Toilet & Bath
V
VI
VII
Using 150 mm thick non-load bearing CHB with 10 mmØ vertical &horizontal rebars at 0.60 m.o.c. Using 100 mm thick non-load bearing CHB with 10 mmØ vertical &horizontal rebars at 0.60 m.o.c. 12 mm thick (min.) to w5 mm thick plain cement plaster finish.
4. Toilet & Bath Wall
Using 200 mm x 300 mm imported glazed wall tiles up to the ceiling line with a single line accent samples of which were approved by the owner.
5. Exterior Window Casting
Using pre- cast moulding along lower edge and cast in place moulding along upper and vertical edges.
6. Baseboard
Using from 25 mm x 100 mm Tanguile, kiln dried along all corners of wall & flooring except T & B.
FLOOR & FLOOR FINISHES 1. Balcony, Foyer, Living, Dining and Kitchen
Using 300 mm x 300 mm floor tiles for exterior sample of which was approved the owner.
2. Bedrooms
Plain cement finish.
3. Toilet& Bath
Using 200 mm x 200 mm floor tiles whose shade shall match the walls’ as verbally agreed with the owner.
4. Second Floor
30 mm to 400 mm thick concrete topping with plain cement finish.
CEILING & CEILING FINISHES 1. Living and Dining, Kitchen & All Bedrooms
Using 12 mm thick Gypsum board on metal framing.
2. Balcony & Eaves
Using 12 mm thick Fibercement board on metal framing.
3. Ceiling Cornice
Using from 25 mm x 75 mm wooden cornice at T & B area and from 25 mm x 100 mm at all other areas.
STRUCTURAL STEEL ROOF
Using open web angular steel trusses as
FRAMING
main frame anchored on 10 mm thick base plate with 16 mmØ anchor bolts, Ga. 16 mm x 50 mm x 100 mm cee purling with 12 mm Ø sag rods all of wich conforming to ASTM- A36.
VIII
PRE- PAINTED LONG SPAN G.I. ROOFING & ACCESSORIES
Using Ga. 26 stile roof profile, Ga 26 ridge cap and Spanish gutter.
IX
DOORS AND WINDOWS 1. Main Door
X
XI
using from 50 mm x 150 mm Narra door jamb and solid Narra panel door with carving design.
2. Bedrooms Door
Molded panel with rectangular shaped designs on 50 mm x 150 mm Tanguile floor jamb, kiln dried.
3. T & B Doors
Using PVC hollow core flush door and jamb.
4. Exit Door at Kitchen
Using Tanguile panel door.
5. Windows at Living, Dining, Bedrooms, T & B and Kitchen
French type window frame using Z- bar, Ibar and T- bar with 4.5 mm thick clear glass.
MISCELANEOUS HARDWARE 1. Door Hinges
Using 75 mm x 75 mm brass plated, loose pin, butterfly hinges or equivalent.
2. Main Door Lockset
Using Schlage with double lock made in US or equivalent.
3. Bedroom Locksets
Using Schlage orbit type.
4. Barrel Bolt
Ordinary barrel bolt to be used for doors @ water closet enclosure.
5. Flush Bolt
Shall be used at upper and lower corners of sliding door.
OTHER FINISHING WORKS 1. Main Kitchen Counter
Concrete granite countertop and 100 mm splashboard over which shall be 200 mm x 200 mm glazed tiles up to the bottom of overhead cabinet.
2. Dirty Kitchen Counter
Concrete with 200 mm x 200 mm tile finish including the splashboard.
3. Kitchen Base Cabinet
Using solid wood with design for doors and for the other parts using moistureresistant melamine laminated boards.
4. Kitchens Overhead Cabinet
Same as base cabinet
5. Pantry Cabinet
Using melamine laminated boards as shown and approved by the Owner.
6. Stair’s Steps Finish
Using 50 mm x 300 mm solid Tanguile.
XII
XIII
7. Stair’s Risers Finish
Using 12 mm thick plywood.
8. Stair’s Railing and Handrail
Using from 75 mm x 100 mm Tanguile kiln dried Handrail and from 50 mm x 50 mm baluster railing.
WATERROOFING WORKS 1. T & B
PLUMBING WORKS 1. Plumbing Works
Using PVC pipes and fittings, Netlex or equivalent, Sch. 40, S- 6000 for sanitary & vent lines and PPR pipes & fittings.
2. Plumbing Fixtures
Using Kohler brand for water closets, bath tub and lavatory fixtures. Single and double bowl kitchen sink shall be stainless of imported brand including their goose neck faucets and other accessories.
3. Downspout
Using 75 mmØ PVC pipes and fittings, Netlex or equivalent, Sch. 40, S- 1000.
4. Drainage Line
Using 150 mmØ and up non- reinforced concrete pipes with mortar jointing.
5. Catch Basins
0.40 m x 0.60 m deep CHB catch basins with concrete base and cover.
XIV
SEPTIC VAULT
XV
ELECTRICAL WORKS 1. Electrical Conduits
XVI
Using three (3) coats of Weathercoat by brush applications.
Construction of 1.50 m wide by 2.50 m long by 1.50 m deep two- chambered septic tank using 150 mm thick non- load bearing CHB with vertical & horizontal rebar and with reinforced concrete base and cover
Using PVC pipes & fittings by Netlex or equivalent.
2. Utility Boxes, Junction Boxes
Using Ga. 16; G.I., deep type.
3. Wiring Devices
Using National brand or equivalent.
4. Wires and Cables
Using stranded wire, Phelps Dodge or equivalent.
5. Panel Boards and Circuit Breakers
Using brand manufactured by duly accredited supplier and in accordance with the electrical code of the Philippines.
6. Lighting Fixtures
Using fluorescent bulbs and pinlights by G.E. or equivalent.
PAINTING WORKS 1. Concrete Wall and Ceiling
2. Wooden Ceiling
Using gloss latex by roller application, Boysen brand. Using flat wall enamel by roller
application, Boysen brand. 3. Doors and Jambs Except Main Door
All painted with enamel by Boysen brand.
4. Main Door & Jamb
Natural Varnish, Boysen brand or equivalent.
5. Steel Railings, Window and Grilles and Sliding Doors
Enamel paint by brush application, Boysen brand.
6. Baseboard, Cornice Casting, Stair Handrail and Balluster
All varnish with same color/shade to match the laminated flooring.