NeuViz
64e
is
during you busy work. The convenient
the
newest
work flow can save you much more
of
time, improve your working efficiency,
Neusoft. It will
and give you more comfortable work
bring
experience.
product
our
customs
more
comfortable application experience, higher quality images and lower dose.
N e w a d v a n c ed t e c h n o l o g y
Iterative algorithm, coronary and vessel analysis, lung nodes analysis and much more advanced application, application,
I n t e r n a t i o n a l q u a li t y e n s u r e d
The tube and detectors are also from Philips, lasts the NeuViz series’ high
bring our patient more safety, all-sided clinical application.
quality design. It also keeps the international classic level. B a se d
on
w indow s
7
o p er a t i o n
system .
NeuViz 64 console is based on windows 7 operation system. It brings us more safety operating environment, more
humanization
operation
interface.
NeuViz 64e New
o p e r a t io n
i n t e r f a ce
and
c o n v e n ie n t w o r k f l o w .
New interface designed, cool color collocation, it bring you cool feel
Bring us m ore……
H a r d w a r e Co n f i g u r a t io n
Number of Detector Elements: 1 Gantry System 672X32
Aperture: 70 cm
Total Channels per Slice: 1344
Scan Field: 50 cm Number of Projections: 4640
Tilt: ± 30° Rotation Time: 0.39s 0.5s 0.6s 0.8s 、
1.0s
1.5s
、
、
、
2.0s
、
、
Sequence Acquisition Modes: 64x0.625, 32x0.625, 16x0.625, 8x0.625,
Partial Scan Times (240°): 0.25s, 0.32s,
4x0.625,2x0.625
0.39s, 0.52s, 0.65s, 0.97s, 1.3s
Spiral Acquisition Modes:
Focus-to-isocenter Distance: 570mm
64x0.625, 32x0.625, 16x0.625
Focus-to-detector Distance: 1040mm
Detector: Up to 30% SNR improvement compared to conventional CT detectors;
2 Data acquisition system Max. number of Slices/Rotation: 64 Slices/Rotation
Number of Detector Rows: 32 Rows
Down to 1us~2us decay time for sub second scan application; Ultra low afterglow; Special design to minimize electronic noise; High geometric efficiency
3 X-ray tube & Generator
Tube Current Range: 30mA~667mA Tube Voltage: 80kV 、100kV 、120kV 、 140kV
Tube Anode Heat Storage Capacity: 8.0 MHU
2
processor
Standard Monitor: Flat Screen Monitor 19” (48 cm) 1,280 x 1,024 Resolution 1,024 x 1,024 Image Display Matrix 0.29 mm Pixel Size
Cooling Rate: 931 kHU/min Dual Monitor: Support Dual Monitor Focal Spot Size: 0.6×1.2(Small ); Flat Screen Monitor 19” (48 cm) 1.1×1.2(Large)
RAM Storage: 36 GB
Max. Power: 80kW
Image Storage: 500 GB; 960,000 Uncompressed Images
4 Patient Table
Additional Storage: CD-R 700 MB
Max. table Load: 205kg/452 lbs Table Feed Speed: 1mm/s-160mm/s
1,100 Images DVD DICOM Drive 4.7 GB DVD Media
Vertical Table/Travel Range: 430mm 8,400 Images -970mm
Vertical Travel Speed: 9 mm/s-15 mm/s
Write-RW/+RW/-DL/Read
DICOM Viewer: Included on each CD; Automatically started on the viewer’s PC
Scannable Range: 1750mm
5 Host Computer systems High-performance Computer: Host: 1 x Quad Core Intel(R) Xeon(R) Recon: 2 x Quad Core Intel Xeon 2.40GHz
3
6 AVW workplace systems
7 System software Patient Registration:
Direct
input
of
High-Performance AVW
Computer: Dell
patient information; Acquisition Workplace
workplace
Precision T1600
provides
Standard Monitor: Flat
the unique
Screen Monitor 19”
advantage
RAM Storage: 8GB
of an
Image Storage: 700
efficient
GB; 1,400,000
examination without entering patient data
multi-moda
Uncompressed Images
before
lity
Additional Storage:
diagnostic workflow
CD-R 700 MB
at a single
1,100 Images
workplace. It manages
DVD DICOM Drive 4.7 GB
the clinical
DVD Media
immediately prior to scan; Pre-registration of patients at any time prior to scan; Special emergency
patient
registration
scanning);Transfer
of
(allows
patient
information from HIS/RIS via DICOM get Worklist;
Transfer
of
examination
information from scanner into HIS/RIS via MPPS (Modality Performed Procedure Step)
diagnostic workflow
8,400 Images
anywhere
Write-RW/+RW/-DL/Rea
within the
d
clinical
DICOM Viewer:
environme nt
Included on each CD; Automatically started on the viewer’s PC
Up to 10,000 protocols can be edited, modified, and stored, the doctors can modify and create the protocols freely!
4
Topogram
8 image reconstruction Real-Time
Display:
Real-time
Length: 50–1700mm
display during spiral acquisition.
Scan Times: 1.5–18 s
Scan Field: 50 cm
image
Recon Field: 5–50 cm Views: A.P., Lateral, Dual
Recon Time: Up to 20 images/s with full
Real-Time Topogram: Yes
cone beam reconstruction
Recon
Matrix:
512x512,
Sequence Acquisition
1024x1024
Reconstructed Slice Widths: 0.625, 1.25,
HU Scale: –1,0240 to +3,2767
768x768,
9 CINE Display 2.5, 5, 10mm
Dynamic Multi-Scan: Multiple
Display of Image Sequences Automatic or Interactive with Mouse Control
Max. Image Rate: 30 frames/s (continuous) sequence scanning without
10 Filming
table movement for fast dynamic contrast
Digital film documentation, connection to a suitable digital camera.
studies with maximum slice thickness of 20
Connection via DICOM Basic Print
mm
Interactive Virtual film Sheet
10 Image transfer/Networking Contrast studies with maximum slice thickness of 20 mm.
Multi-slice Spiral Acquisition Reconstructed Slice Widths: 0.625,0.8,1,1.25,1.5,2,2.5,3,4,5,6,7,8,9,10 mm
Slice Increment: 0.1–20 mm Spiral Scan Time: Max. 100 s Scan Length: Max. 1700mm
Interface for transfer of medical images and information using the DICOM standard. Facilitates communication with devices from different manufacturers. DICOM Storage (Send/Receive) DICOM Query/Retrieve DICOM Basic print DICOM Get Worklist (HIS/RIS) DICOM MPPS DICOM Storage Commitment DICOM Viewer on CD
5
11 RawData Capacity: 800GB 12 Report Report has following features: Edit report document, save and print Manage report document, list, filter Support report template design Support multiple page Supply case management
13 Image Quality High-contrast resolution Isotropic high-contrast resolution in all three planes (x, y, and z).
X-Y-plane: 0%MTF 17lp/cm, 0.29mm
Dose, CTDI100 Values (mGy)
10%MTF 11lp/cm, 0.45mm
Phantom
Position
80
100
120
140
KV
KV
KV
KV
A
4.7
9.5
15.3
22.0
B
5.2
10.
16.7
24.0
50%MTF 7.5lp/cm, 0.66mm
Z-Plane: 0%MTF 15.4lp/cm, 0.32mm
16cm 10%MTF 10.9lp/cm, 0.46mm
4
50%MTF 6.5lp/cm, 0.77mm
Technique:Technique 245 mA, 120 kV, 1.0
A
1.3
2.8
4.9
7.4
B
2.5
5.5
9.6
14.4
32cm
s, 0.625 mm
*A: at center B: 1 cm below surface
6
So f t w a r e f o r A p p l ic a t i o n
M I P / M in I P / A ve I P
Maximum,Average orMinimum
1 Post-processing M P R / CM P R
Real-time reformation of axial images into any user-defined plane coronal, sagittal or general oblique or curved plane. Interactive and friendly user interface is provided. 3 D / SSD
Provides fast reconstruction of 3D images and easy to understand presentation of complex anatomy
7
Intensity Projection. projection images can be interactively
2 Advanced Software Bolus Tracking
generated in any arbitrary viewing angle, and can be windowed, zoomed and panned VE
Fly-through images within and around hollow organs. Clinical applications include virtual colonoscopy bronchoscopy, and angioscopy. VR
3-D visualization software provides unique simultaneous visualization of vasculature, soft tissue and bone. Unlike conventional 3-D or MIP, volume rendering visualization offers real time interactive control over opacity and transparency values to permit viewing through and beyond surrounding structures.
An automated injection planning technique that permits the user to monitor actual contrast enhancement and initiate scanning at a predetermined enhancement level. Combine with SAS for full automation and efficacy.
SAS Spiral Auto Start integrates the injector with the scanner, allowing the technologist to monitor the contrast injection to check for extravasation and to initiate and stop the scan (with the pre-determined delay) while in the scan room.
Vessel Measurable Analysis Following functions is supported in Vessel Analysis
NeuViz 64 brings us high quality images and gives doctors more
Application:
fine-detail information.
8
One click bone removal;
Dental Analysis is designed for assisting oral
Vessel centerline extraction;
surgeons
Various review modes may be used: Volume
in
planning
implantation
of
prostheses. It has following features:
Rendering ,MIP,MPR,CPR;
Display panoramic views of dental.
Measurements are provided for vessel
Display cross-sectional planes of dental.
assessment, including maximum and minimum
Filming the panoramic and cross sectional
cross section diameters, lumen areas.
images in true size.
Nerve System DSA Nerve System DSA Application is used to remove
boney
structures
and
reveals
vascular structure in the skull. It has following features; Auto registration of contrast and without contrast series; Auto subtraction of bone structures; Rendering Modes: VR, MIP and MPR.
Brain Perfusion
Dental Analysis
9
Left and right lung emphysema Brain
Perfusion
is
a
blood
flow
imaging
measurements;
application ,It has following features:
Visual representation of the diffusion of the
Preprocess image(delete bad, sort, recalculate)
emphysema
Calculate CBF, CBV, MTT, TTP Map
Three-Dimensional Lung Nodule
ROI and TDC display Send result to Film & Report
Analysis The Lung Nodule Analysis application assists
Body Perfusion
the
Body Perfusion application is an advanced
quantification of pulmonary nodules and
application for the quantitative analysis of
lesions:
renal, hepatic, and pancreatic blood flow. It has following features: Calculate CBF, CBV, MTT, TTP,PS Map ROI and TDC display
radiologist
with
the
detection
and
Single click segmentation Nodule volume calculation Follow up support: growth of nodules can be tracked over time
Coronary Calcium Scoring* Send result to Film & Report
Coronary Calcium Scoring application is used
Lung Density
to estimate the amount of calcium in the
Lung Density is an automated application
coronary arteries.
that provides quantitative (volumetric) lung
Coronary Artery Analysis**
emphysema measurements and a visual
Coronary Artery Analysis application is used
representation of the diffusion of the
to analysis coronary artery disease from CT
emphysema. It has following features:
Scan data.
Automated left and right lung segmentation;
It has following features:
Automatic Cardiac cage removal
10
Automatic Cardiac Segmentation and Cardiac Artery tree extraction
Virtual Colonoscopy Virtual colonoscopy application is a clinical
Manual Segment of cardiac artery Render modes: VR,MIP,MPR,CPR Reporting
application for the viewing and evaluating of virtual colonoscopy CT images. The application is an interactive tool to help
Stenosis measurement
visualize colon anatomy, find polyps and
Cardiac Function
Analysis **
The Cardiac Function
Analysis application
allows you to analyze a variety of heart functions, including:
assess their characteristics.
Optional feature for Host workplace and AVW workplace
Left ventricular volumes
Optional feature for AVW workplace
Ejection fraction Left ventricle wall motion and thickening Using Simpson or Segmentation methods of calculation
isotropic
Tumor Evaluation **
and
volume
acquisition
using
prospective ECG triggered or retrospective
Tumor Evaluation Application can provide segmentation
Heart Scan System Heart-scan CT with ECG-synchronized true
4D Rendering
tumor
only
measurements
from CT Scan series: One click tumor segmentation Tumor diameter and volume calculation Follow up support
ECG-gating mode. The ECG signal used for gating the CT images is acquired by an ECG device. The ECG signal is displayed on the ECG device and the scan interface. Temporal resolution can reach down to 66.7High/83Low ms.
RECIST measurement support
11
80/400/415/440/460/480VAC)
Installation
Voltage Variation: ±10%
Gantry Dimensions: 2244mm (L) x 890mm (W) x 1920mm (H)
Package:
2370mm
≤5%
Frequency: 50/60Hz±1Hz
Gantry Weight: 1800Kg Gantry
3-phase Unbalance:
Grounding (L)
Resistance:
4Ω
x (independent grounding system);
1030mm (W) x 2250mm (H)
Dimensions
1Ω(complex grounding system)
Couch Dimensions: 2400mm (L) x
Min.
610mm (W) x 1055mm (H)
5550mm×3650mm
Couch Weight: 350Kg
Min. Area of Operating Room:
Couch
Package
Dimensions:
Area
of
Scanning
room:
1700mm×3650mm
2570mm (L) x 970mm (W) x 1230mm
Recommended Room Size:
(H)
Operating Room: 3000mm×4600mm
Console
Table
Dimensions:
Scanning Room: 6000mm×4600mm
1400mm (L) x 800mm (W) x 760mm (H)
Min. Height of Ceiling: 2010mm
Power Supply Requirements
Temperature of Scanning Room:
Power Capacity: 100KVA
Scan room 18℃~24℃;
Input Voltage: 380/400VAC Control room 18℃ ∼ 28℃ 3-phase 5-line 3-phase 4-line(Export is
Humidity of Scanning room:
equipped with isolate
Scan room 30%~60%;
transformer), power supply from below
Control room 20%~80%
options:190/200/208/220/230/240/3
Atmospheric Pressure:
12
70kPa~106kPa
Temperature of Transportation and Storage: -20℃~+55℃ Humidity of Transportation and Storage: 10%~90%, no-condensing Running Noise: no more than 70dBA
***A l l p a r a m e t e r s s u b j e c t t o c h a n g e w i t h o u t n o t i ce .
Neusoft Medical SystemsNeusoft Park, Hun Nan Industrial Area,New & High-Tech. Development Zone,Shenyang 110179, P. R. ChinaTel : +86 24 8366 1883 Fax : +86 24 2378 2797
Authorized Distributor:
13