Flow Computer and Loading Control System MFX_4
M+F
Mess– und Fördertechnik Gwinner GmbH
[02]
[MFX _4]
The MFX _4 reflects the vast experience of M+F, one of the pioneers of Flow Computers for custody transfer measurement. The MFX _4 incorporates proven proven technology never before used in the design of industrial Flow Computers.
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[03]
[MFX _4]
Competence in Liquids Handling
Designed for many challenges: MFX_4 Applications The Flow Computer System MFX_4 is the 4th generation of M+F’s Flow Computer series. There are more than 10.000 MFX Flow Computers in operation throughout the world. The MFX _ 4 Flow Computer is capable of covering a wide variety of applications, ranging from truck loading, pipeline metering/proving to multi–component blending applications.
MFX _4
Applications
Truck Loading
Top Top
Rail Car Loading CONTROL ROOM
Bottom
Ship / Barge CONTROL ROOM
Pipeline Metering
Blending SCADA
On Truck Applications
Heating Oil Truck
CONTROL ROOM
SCADA
Refueller
COMPACT
COMPACT
Dispenser
CONTROL ROOM
M+F
Mess– und Fördertechnik Gwinner GmbH
[04]
[MFX _ 4]
The MFX _4’s flexibility comes from its vast number of optional features.
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[05]
[MFX_ 4]
Competence in Liquids Handling
Supreme capabilities: MFX _ 4 Features
MFX _ 4 Controller is the Flow Computer Module
MFX_4 Terminal is the Human–Machine–Interface Human–Machine–Interfa ce Module
Standard Features
Optional Features
Single or multi product operation
Interface to density meter
Flow control for digital or analog valves valves Dual pulse security
• freq frequency uency direc directt from density density meter meter • 4–20 mA 24 24 bit from from density density conv converter erter
Configurable Configurab le inputs/outp inputs/outputs uts
Inline blending ratio and sequential
Automatic Temperature and Pressure Compensation
Multi–product blending [max. 16 products]
Preset for Batching with Automatic Trip Correction
Additive Control
Meter Factor Calculation and Meter Curve Li nearisation [4 points per product] Configurable Configurab le Pulse Outputs Graphic Display with Multi –Language Capability
• Integ Integrat rated ed Controlle Controllerr analog and and digital digital for max. 10x additives [e.g. M+F CBU] • Seria Seriall Interface Interface to Smart Smart Additive Additive Controlle Controllerr [e.g. M+F/Lubrizol]
Automatic Error Handling and Reporting
Pipeline Metering Application
Integrated Integrate d Log–Book for Selected Events
Meter Prover Application
Manual or Automatic Mode Selection
Integrated ID Card Reader
Configurable Configurab le I/O Sequencing 7 Security Levels Field Bus Communication CANopen
• Pr Proxi oximit mity/Tr y/Trans anspon ponder der • Wi eg egand PC–based features:
LAN Communication Ethernet TCP/IP
• O PC PC Se Se rv rve r
Serial Interfaces RS232/RS485/RS422
• Mete Metering ring and and Proving Proving Cont Controlle rollerr MPC
Storage of up to 200 Tr Transactions ansactions per Meter Remote Maintenance via Diagnostic Interface
• Multi Prod Product uct Blendin Blending g Contro Controller ller PC–based Service Tools • MFX _4 Explorer
M+F
Mess– und Fördertechnik Gwinner GmbH
[06]
[MFX _4]
Competence in Liquids Handling
The MFX _4 Architecture: Modules
M+F
Mess- und Fördertechnik Gwinner GmbH
[07]
[MFX_4]
Competence in Liquids Handling
Integrated ID–Card Readers
Bat atch ch Pr Pro oxi ximi mitty Car Card d Re Read ader er
Wieg Wi egan and d Car Card d Re Read ader er
The system architecture of MFX_4 is modular: its functions are distributed among individual modules that communicate communicate via CANopen.
Integration into Automation Environment
OPC SERVER SCADA
These modules are available in [Ex]– and non–[Ex] housings and can be positioned and configured in exactly the way that is required by the application. TCP/IP
• The core core module is the Flow Computer Computer,, the MFX _4 Controller. • The Human–Machine–Interface is the MFX _ 4 Terminal with integrated CAN interface. • The CUT and EDI are gateways gateways to TCP/IP.
Flow Computer
MFX_4 Controller
Human–Machine–Interface [HMI]
Flow Computer and HMI combined in one [Ex] housing
Communication Gateways Gateways
MFX_4 Terminal
MFX_4 Compact
MFX _4 EDI
MFX_4 CUT
Field
Rack
Field
Field /Rack
Field
Rack
Rack
Controller [EX]
Controller rack mounted
Terminal [Ex]
Terminal non–[Ex]
Compact [Front]
EDI
CUT
OPC Server
The MFX_4 EDI is a gateway between between the MFX_4 modules [CANopen] and a Local Area Network [TCP/IP].
The MFX_4 CUT module offers the same interfaces as the MFX _4 Terminal and is used when a HMI like the MFX_4 Terminal is not required.
The MFX _4 OPC Server is a PC– program [MS Windows–based] that can run on the same PC as the Terminal Automation system [TAS]. It offers complete access to all process data of the MFX _4. The TAS can read and write to tables on the OPC Server with no need to directly interface to the MFX _4.
• • • • • • •
Flow computer for 1 or 2 meter positions positions Digital and analog I/O s Densitometer frequency input Blending Multi–component Additive Injection Bio Ethanol Blending Preset
• • • • • •
Large graphical display Alphanumeric keypad Configurable menu’s Multi language capability Card reader Proximity technology Card reader Wiegand technology
Interfaces
Interfaces
• CANopen • RS 232/485
• CANopen • RS 232 • RS 485 4 wire TCP/IP with 5 ports in parallel
Compact [Back]
The MFX_4 Compact combines a Controller module with a Terminal module in one [Ex]–proof housing. This product is especially suited to small installations where a one–box–design is preferable.
MFX_4 OPC Server
This industry standard field communication is used by a wide variety of instrumentation vendors and guarantees flexibility when adjusting TAS and SCADA systems to the field instruments.
M+F
Mess– und Fördertechnik Gwinner GmbH
[08]
[MFX _4]
Competence in Liquids Handling
Connecting to the Field and Remotely Remotely:: Communication
M+F
Mess– und Fördertechnik Gwinner GmbH
[09]
[MFX _ 4]
Function of the Local Area Network
Competence in Liquids Handling
TCP/IP
Optionally on one PC
Due to its superior communication communication capabilities, the MFX_4 System is very flexible when communicating with the field and remotely. Remote maintenance via the internet or SCADA system becomes a standard feature.
The MFX _4 system communicates to SCADA and Terminal Automation systems [TAS] via TCP/IP on a Local Area Network [LAN]. The SCADA or Automation System does not need to know the proprietary proprietary communication protocols protocols of the MFX _4. It interfaces with the OPC Server on the LAN.
TAS/SCADA
TCP/IP
It can thus read and write data in the tables of the OPC–Server which can be installed on the same machine as the automation system, or can be accessed via the LAN from another machine. [See page 18: „Communication between MFX_4 and Te Terminal rminal Automation“] Alternatively, Alternatively, the MFX _4 can communicate with the SCADA or Automation System in a more traditional manner via RS232 or RS 485 serial communication.
OPC SERVER
TCP/IP
5 Ports
Communication via Fieldbus
CANopen
The MFX_4 modules communicate via the fieldbus CANopen. This ultra fast and highly secured bus system has been field proven for many years and is widely used in industrial areas where high speed data exchange is required [i.e. the automotive industry].
• Terminal HMI • CUT • EDI • Compact
CANopen Field bus
The CANopen controllers are integrated into any MFX _4 module.
Connection to the field instruments
Field I/0s
• Controller [Ex] • Controller rack • Controller non [Ex] • Compact
The field instruments connect directly into the MFX _4 Controller. The MFX _4 design allows for optimum integration of field I/Os into the system: i.e. densitometer frequency signals can be directly connected without need for an extra converter.
CANopen Field signals
M+F
Mess– und Fördertechnik Gwinner GmbH
[14]
[MFX _4]
Truck Bottom Loading
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[15]
[MFX _4]
Aircraft Refuelling
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[16]
[MFX _4]
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[17]
[MFX_4]
Competence in Liquids Handling
MFX_4 Flowcomputer System OPC Server for MFX _ 4 The MFX_4 System can be connected to an OPC Server via TCP/IP on the LAN. The OPC Server is a program that runs on a PC, either separate separate or on the same PC as the Automation System.
instruments. Thus, the OPC technology makes communication more transparent and flexible in case of future changes to the field instrumentation.
The OPC Server makes all data from the MFX _4 Flow Computer available for other systems [like Terminal Automation or SCADA Systems] to use. The data is easily accessible to an OPC Client through read/write tables.
OPC is an international standard for field–to–Control Room communication. Many major suppliers of field instrumentation are offering OPC Servers and Clients for their products.
The OPC structure is similar to that of the Windows Explorer. Explorer. Without knowledge of the field instrument or OPC Server, the SCADA System’s OPC client can access all process data in a hierarchical hierarchical structure, as shown in the example below. In this example, the SCADA system reads the Loading Data from the MFX_4 Controller No. 1 [Meter Run No. 1]. All Loading Data is accessible by Reading/Writing from/to a table within the OPC Server.
Communication between MFX _4 and OPC Server is at high speed and ful fills all requirements for automation systems. systems. By accessing the data from tables on the OPC Server, the Automation System does not require proprietary protocol protocol drivers for the field
Communication between MFX _4 and TAS via OPC Server
Fast Availability Availability of all Data of MFX _04 in Tables for Read/Write
An example of data exchange between TAS and MFX_4 during loading operations.
The TAS needs no knowledge of the MFX _4’s communication protocol, since it reads/writ reads/writes es all data in structured tables from the OPC Server Server..
OPC Server
OPC Client
OPC
TAS
TCP/IP
The MFX_4 communicatess directly communicate with the OPC Server. MFX_4 CANopen
The TAS system has written the Preset Values into the relevant OPC table.
After loading is completed, the MFX _4 transmits the data to the OPC Server where it is made available to the TAS.
The OPC Server transmits the Preset values for the next load to the MFX _4.
The TAS reads this data from the relevant tables.
M+F
Mess– und Fördertechnik Gwinner GmbH
[18]
[MFX _4]
Competence in Liquids Handling
Communication between MFX _4 and Terminal Automation There are several ways to connect a Terminal Automation System [TAS] with the MFX_4. Ideally, the TAS communicates on a LAN via the OPC Server with the MFX_4. But there are also other possibilities to connect the automation level with the flow computer.
TAS peer to peer with MFX _4
The TAS can communicate directly with the MFX_4 using the serial interfaces RS 232 or RS 485. It uses M+F’s MCO1 protocol. In case of this kind of connection to the MFX _4, the TAS needs to handle handshake communication. Also, the TAS needs to be programmed programmed in such a way to handle this proprietary protocol.
TAS peer to peer with OPC
TAS on LAN with OPC
OPC peer to peer with MFX _4
OPC on LAN with MFX _4
The TAS communicates communicates directly with the MFX_4’s OPC Server.
The TAS communicates communicates on the LAN w ith the MFX_4’s OPC Server. The OPC Server can run on the same PC as the TAS.
In fact, the OPC Server can run on the s ame PC as the TAS. The OPC Server can communicate directly with the MFX_4 using RS 232 or RS 485. The OPC Server is linked via serial interface with the MFX_4, using the MCO1 protocol.
The OPC Server communicates with the MFX _4 using TCP/IP on the LAN. Advantage: •
TAS does not not use proprie proprietary tary protocol protocol and handshake with MFX_4 all MFX_4 data available on OPC in tables for read/write • in case of changes changes of of flow comput computers ers in the the field, no need for reprogramming of TAS communication •
OPTIONALLY ON ONE PC
TAS OPC
TAS
TAS
RS 232 RS 485
RS 232 RS 485
proprietary protocol
proprietary protocol
OPC
TAS
TCP/IP
M+F
Mess– und Fördertechnik Gwinner GmbH
[19]
[MFX_4]
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[20]
[MFX _4]
Competence in Liquids Handling
M+F
Mess- und Fördertechnik Gwinner GmbH
[21
[MFX_4]
Competence in Liquids Handling
MFX_4 Explorer
Remote Maintenance with the MFX _4 Explorer
The MFX_4 Explorer is PC–based software software that provides access This program provides the following functionality to all parameters of the MFX_4 system. • Parameter Parameter setting
Due to the MFX_4’s TCP/IP communication capabilities, the system can easily be serviced via the internet over large distances, even internationally.
This software is used as the main access tool by operators and service personnel for configuring the MFX_4. It also provides a wide variety of additional features that make the MFX_4 simple and flexible to use. Its layout offers easy navigation through its many functions.
•
Logging of communication
•
Log book [History of data]
•
Parameter Parameter and configuration data base base
•
Setting of prover variables
•
Access to to all variables of the OPC Server Server for MFX _4
Since uploads are separately possible for the weights and measures or for the general part of the software, it is possible to upload firmware updates without breaking the calibration seal.
Using the MFX_4 Explorer as a Service tool, it is possible to access the MFX _4 during full loading operations, to analyse the real–time data. It is also possible to view and alter parameter settings and upload firmware updates via this software.
Firmware Upload
Display of current Loading Data
For servicing: analysis of current pulses during loading operation
Remote Maintenance via the internet
CENTRAL SERVICE SUPPORT OF OIL COMPANY
INTERNATIONAL SERVICE SUPPORT
SERVICE LAN AT M+F MFX_4 EXPLORER
VIRTUAL PRIVATE NETWORK
TERMINAL LAN OF OPERATOR
SERVICE LAN
VPN
VIRTUAL PRIVATE NETWORK VPN
SERVICE HEAD–QUARTER
LAN OF TERMINALS
Real time update of pulse data
Uploading of Firmware Update
M+F
Mess– und Fördertechnik Gwinner GmbH
[22]
[MFX _4]
Competence in Liquids Handling
Metering and Proving Control Manager MPC Manager
M+F
Mess– und Fördertechnik Gwinner GmbH
[23]
[MFX_4]
Competence in Liquids Handling
Dual Chronometry
PC Program for batch and prover handling in conjunction wih Flow Computer MFX_4
Actual time interval
In a typical pipeline metering system, an MFX _4 Controller is dedicated to each meter run as well as the prover. Since the hardware functionality [like dual chronometry] of the MFX _4 Controller is standard, the same hardware can be used for the meter-dedicated meter-dedicated and prover–dedicated units.
Due to the MFX_4's direct link via TCP/IP communications, all process control functions can be handled on the LAN. This applies to the Pipeline Process Manager program and the SCADA system; all existing data from the field instrumentation can be accessed via the OPC Server for the MFX_4 System.
The Start/Stop signals from the prover are directly connected to all MFX_4 Controllers within a system, allowing the controllers to monitor the pulses from the relevant meters. meters. All other communication is directed via the CANopen Field Bus to the OPC Server located in the TCP/IP Local Area Network [LAN].
OPC Server MFX_4 Explorer
SCADA System
PRINTER
TCP/IP
MFX_4 EDI
MFX_4 CONTROLER non[Ex] FOR METER RUN NO. 1
MFX_4 CONTROLER non[Ex] FOR METER RUN NO. 2
START / STOP PROVING
Field
Field Signals
METER RUN 1
Field Signals
METER RUN 2
Advantage: Advantage: Higher accuracy of measurement. measurement.
Resolution without Dual Chronometry Pulses
Resolution with Dual Chronometry
The MFX_4 Controllers with Non–[Ex]Housing installed in the Control Room MPC Manager Metering and Proving Control
Dual Chronometry increases the pulse resolution of the flowmeter by dividing each pulse into accurate sub–pulses.
MFX_4 CONTROLER non[Ex] FOR METER RUN NO. 3
START / STOP PROVING
Field Signals
METER RUN 3
MFX_4 CONTROLER non[Ex] FOR PROVER CONTROL
START / STOP PROVING
Field Signals
IE BIDI PROVER
M+F
Mess– und Fördertechnik Gwinner GmbH
[24]
[MFX_4]
Competence in Liquids Handling
M+F
Mess– und Fördertechnik Gwinner GmbH
[25]
[MFX_4]
Technical Data MFX _ 4 Controller
Technical Data MFX _4 Terminal
The MFX_4 Controller is the Flow Computer in the MFX_4 system. It is available in three different housing versions, although the technical specifications of the electronics are the same for all versions. The MFX_4 Controller can both be installed in the field [in hazardous or non–hazardous areas] or inside a rack in the control room.
The MFX_4 Terminal is the Human–Machine Interface [HMI] between the Flow Computer and the operator operator in the field.
Competence in Liquids Handling
It is ruggedly designed for rough field operation and offers a large graphic display which can display clearly readable characters in any languages. The Terminal’s robust keypad has large pushbuttons with a notable ‚click‘ even when used with gloves. The Terminal can also be used as a stand–alone Access Controller for security control within a terminal.
MFX_4 Controller in [Ex]–housing
Technical Data MFX _4 Controller MFX_4 Controller
MFX_4 Terminal [Ex]–version
• Dual Pulse Security
Technical Data MFX _4 Terminal Display
1 4 VGA • Large, Full Graphic Display ⁄
• LED backlit I/Os
• Pulse Input for Additive/Blending • 2x RTD Pt100 4wire
Keypad
• 2x Analog Input 4–20 4–20 mA [expandable — refer data sheet]
• Alphanumeric • 32 keys + 4 Soft Keys
• 2x Analog Output 4–20 4–20 mA [expandable — refer data sheet] • 1x direct direct Density Density Input [Frequency] [Frequency]
I/Os
•
Et Ethernet [TCP/IP] 5 ports
• 12x relais Output AC and and DC [expandable [expandable — refer refer data sheet]
• 2x CANopen Field Bus
• 7x Opto–Input [expandable [expandable — refer data sheet]
• 1x RS 232
• 3x Pulse Output [expandable [expandable — refer refer data sheet]
• 1x RS 485
• 2x Communication Port • 1x CANopen CANopen
Integ Integra rate ted d Batc Batch/ h/Ca Card rd Read Reader erss
• 1x RS 232/RS 232/RS 485 MFX_4 Controller in rack–version
Display
• LCD backlit
• Transp ranspond onder er • Wiegand
MFX_4 Terminal Non–[Ex]–version
Multi–Language
• 2 [4] columns 16 characters characters • 5 Sta Statu tuss LED LEDss
Power Supply
• 24 VDC
Power Supply
• DC or AC
Explosion Proof
• EEX d IIB T6 IP65
Oper Operat atin ing g Tempe empera ratu ture re
• –30/40 30/40°C °C to 60°C 60°C
Operating Temperature
• –30/40°C to +60°C
See Datasheet MFX _4 Terminal for full Technical Technical Data Housing
• Explosion Proof EEX d IIB T6/IP65 • Rack mounted [non–Ex]
Optional
• Plug–in Boards available to expand the number of digital and analog I/Os
M+F
Mess– und Fördertechnik Gwinner GmbH
[26]
[MFX _4]
Competence in Liquids Handling
MFX_4 Compact Combining the MFX_4 Controller with the MFX_4 Terminal in „One Box”
MFX_4 Compact [Ex]–version Front
Technical Data MFX _4 Compact • Technical data same as MFX _4 Controller and MFX _4 Terminal • Explosion proof EEX dIIB IP65 • Power Supply AC and DC • Batch/Card Reader integrated •
Proximity/Transponder
• Wiegand
MFX_4 Compact [Ex]–version Back
M+F
Mess– und Fördertechnik Gwinner GmbH
[27]
[MFX _4]
Competence in Liquids Handling