Method Statement for retubing of Heat Exchanger.Full description
Deep ExcavationFull description
GoodFull description
Method StatementFull description
Method Statement
Full description
Deep Excavation
sika groutingFull description
Method StatementFull description
TOP BUILDERS INTERNATIONAL CO. LTD.
Method Statement For Gypsum Board Suspended Ceiling System
Method Statement for Gypsum Board Suspended Ceiling System
Table of Content
Content
…………..
2
Introduction
…………..
3
Relevant submission
…………..
3
Installation of suspended ceiling system
…………..
3-4
Preparation work
…………..
3
Concerns
…………..
3
Ceiling Installation
…………..
4
Method Statement for Gypsum Board Suspended Ceiling System
Scope of work Trade contractor of this project will be responsible for the execution of the work in accordance with the specifications and relevant approved documentations. The scope of work includes supply and installation of proposed gypsum board suspended ceiling system including proprietary KIRII SD-19 (Standard) System with W-Bar, C-38 Channel, Hanger, W-Clip, Z-Bracket and Bolt and moisture resistant board (MR - GypBoardTM) at the L33 to L37 tower suite bathroom areas.
Relevant submissi on •
•
Material Submission of the KIRII SD-19 (Standard) System including samples and catalogue. Material Submission of the GypBoardTM including samples and catalogue.
Installation of suspended ceiling system •
Preparation work 1. Site Cleaning 2. Site surveying and setting out 3. Erect working platform if necessary and according site safety
Method Statement for Gypsum Board Suspended Ceiling System
2. Mark carrying channel (C-38 channel) by stretch a string across the room at ceiling height. 3. Installation of the 8mm diameter threaded suspension, fixed by using Z-Bracket to the ceiling slab. Spacing of suspension both must be at 1200m max. in either direction and at perimeter of ceiling as r equired. 4. The C-38 channel must be placed at 1200mm Max. shall be hung to the lower part of the suspension bolts by means of galvanized steel hangers and nuts. 5. The W-Bar at a spacing of 400mm Max. shall be fixed to the C-38 channel with W-Clips at each intersection. W-Clips must as a rule alternate with the sides of the carrying channel. 6. Rigid and aligned system for the fixing of ceiling board must be provided with separated pieces of C-38 channel and W-Bar to be jointed by channel joint and double joint respectively. 7. Extra hangers to be provided where opening are required for light fittings and access panels. 8. All components must be well fixed and the suspension system must be correctly aligned and accurately leveled before attaching the
Method Statement for Gypsum Board Suspended Ceiling System
3. Measure the cornice length required and mark wall edge of moulding before screw fixing. Leave enough moulding length beyond the wall edge mark to allow for external mitre cuts. 4. As cutting the mitre in the corner angle, the mitres must be marked out and cut for each individual corner. 5. After cutting the cornice to be proper size, screw casting to wall and ceiling. 6. Fill, joints and screw holes first Herculite Fibrefix. Once the Fibrefix has set finish off the joints and screw holes with plaster, allow to dry and sand smooth.
Review No.
B
Date:
HAZARD IDENTICATION SHEET
16-06-02006
Page 1 of 3
Project:
Venetia Cotai, Macau – Prefabricated Bathroom
Work Package Code:
Subject:
Gypsum board Suspended Ceiling System
Analysis by:
Location:
Hotel Tower
Item 1
2
Job Task General works
Drilling
Hazard Personal injury
eye injury Noise nuisance Body Injury
People Affected worker and affected people nearby
worker and affected people nearby
Cause of Hazard
-
Lack of site safety knowledge
-
Inappropriate use of PPE
-
Defective electric tools being used.
-
Worker did not wear and use PPE
-
No Warning sign
Worst Harm Due to Hazard Severely injured
Fatality
Existing Control Measures
-
Worker should attend Safety Induction Training provided by GAMMON.
-
Provided appropriate PPE as job required.
-
Keep minimum stock of PPE to be maintained for issuing.
-
3
Manual handling and transporting of material
Twisted , slipping, tripping, hit by objects Muscle strain During manual handling
workers
-
Using improper lifting method to handle goods
Severely injured
WP 5115 (Top Builders) Edward Leung
-
-
poor housekeeping
-
-
Worker did not wear and use PPE
-
No patent defect on the electric tools to be used. Appropriate electric tools shall be selected. Monthly inspection of the tools by registered electrician. Fence off the working areas to prevent unauthorized entry. Ensure the workers Wear long sleeve Protective cloths & safety boot Safety gloves & eye protector. Provide pre-work body exercise to minimize the risk of injury Wear long sleeve safety shoes to protect the ankle and foot. Use the mechanical equipment if possible. Always keep the workplace dry and tidy.
Remark
Review No.
Item 4
B
Date:
Job Task Materials
HAZARD IDENTICATION SHEET
16-06-02006
Hazard Fire
storage
People Affected worker and affected people nearby
Cause of Hazard
-
-
Poor Housekeeping
Page 2 of 3
Worst Harm Due to Hazard Fatality
Smoking at the workplace and storage yards.
Existing Control Measures
- Flammable materials and goods must be kept away from the workplace.
- Provide fire extinguishers at the workplace and storage yards.
- Clean all the rubbish, paper, scraps all the time.
Insufficient Ventilation
- Display “no smoking’ signage and no smoking is allowed at the workplace.
5
Ceiling Installation
Collapse of working platform
6
Ceiling installation
Fall of person at height
worker and affected people nearby worker
Platform erected by non-experience competent workers.
Serious injury
- Adequate ventilation - Appointed Registered professional
-
Inadequate platform being used by workers.
Fatality
-
-
Workers did not wear and use PPE.
-
inspect and sign for the workability of working platform of height above 1.8m.
-
200mm high toe-board and fence at 450mm and 900mm to be installed. Prohibit to move the working platform if any worker on it.
Remark
Review No.
Item 7
B
Job Task Ceiling installation
Date:
HAZARD IDENTICATION SHEET
16-06-02006
Hazard Falling objects from the working platform
People Affected Worker and affected people nearby
Cause of Hazard
-
Worker working under the working platform.
-
No Warning sign
Page 3 of 3
Worst Harm Due to Hazard Severely injured
Existing Control Measures
-
Working platform should be closely planked with 200mm toe-board equipped.
-
No other works shall be carried out under the activities that are working above.
-
Chain block shall be used to the materials that are heavy in weight and large in size.
-
Fence off the working area with barrier and notice / warning sign should be provided.
Remark
Review No.
B
Date:
Works Related Projects/Department: Type of Activity Operation: Location:
Hotel Tower
Item
Risk
1
Personal injury
-
Worker should attend Safety Induction Training provided by GAMMON.
-
Provided appropriate PPE as job required.
eye injury
-
Noise nuisance
-
Body Injury
-
3
Twisted , slipping, tripping, hit by objects
-
Muscle strain During manual handling
Note:
Venetia Cotai, Macau
-
Keep minimum stock of PPE to be maintained for issuing. No patent defect on the electric tools to be used. Appropriate electric tools shall be selected. Monthly inspection of the tools by registered electrician. Fence off the working areas to prevent unauthorized entry. Ensure the workers Wear long sleeve Protective cloths & safety boot Safety gloves & eye protector. Provide pre-work body exercise to minimize the risk of injury Wear long sleeve safety shoes to protect the ankle and foot. Use the mechanical equipment if possible. Always keep the workplace dry and tidy.
Probability or Likelihood Rating: Consequence Rating: Risk Level:
Almost Certain ( 5 )
Page 1 of 3
Works Related Projects/Department Code:
Prefabricated Bathroom
Existing Control Measures
2
RISK ASSESSMENT SHEET
16-06-2006
Analysis by: Rating of Harm 1
2
Risk 3 Level
Recommended Action
Probability
Consequences
3
1
3 (Green)
2
3
6
2
WP 5115 (Top Builders)
Edward Leung
2
Probable ( 4 )
Possible ( 3 )
Very High ( 5 )
High ( 4 )
( RED )
( ORANGE )
Safety Induction Training, Specific PPE required
Specific PPE required
(Green)
Training required
4 (Green)
Morning Pre-work exercise
Remote (2 )
Impossible (1)
Medium ( 3 )
Low ( 2 )
Very Low ( 1)
( YELLOW )
(GREEN)
Remark
Review No.
Item 4
5
6
Note:
B
Risk
Date:
RISK ASSESSMENT SHEET
16-06-2006
Existing Control Measures
Fire
- Flammable materials and goods must be kept away from the workplace. - Provide fire extinguishers at the workplace and storage yards. - Clean all the rubbish, paper, scraps all the time. - Display “no smoking’ signage and no smoking is allowed at the workplace. - Adequate ventilation
Collapse of working platform
- Appointed Registered professional
Fall of person at height
- 200mm high toe-board and fence at
inspect and sign for the workability of working platform of height above 1.8m.
450mm and 900mm to be installed. - Prohibit to move the working platform if any worker on it.
Probability or Likelihood Rating: Consequence Rating: Risk Level:
Almost Certain ( 5 )
Page 2 of 3
Rating of Harm 1
2
Risk 3 Level
Recommended Action
Probability
Consequences
1
5
5 (Green)
Fire equipments Training, Specific Training
3
3
9 (Yellow)
Specific Training
2
4
8 (Yellow)
Specific Training & Safety Harness required
Probable ( 4 )
Possible ( 3 )
Remote (2 )
Impossible (1)
Very High ( 5 )
High ( 4 )
( RED )
( ORANGE )
Medium ( 3 )
Low ( 2 )
Very Low ( 1)
( YELLOW )
(GREEN)
Remark
Review No.
Item 7
B
Date:
Risk Falling objects from the working platform
RISK ASSESSMENT SHEET
16-06-2006
Existing Control Measures -
Working platform should be closely
Page 3 of 3
Rating of Harm 1
2
Probability
Consequences
4
2
planked with 200mm toe-board
Risk 3 Level
Recommended Action
8 (Yellow)
Specific Training & Safety Harness required
equipped.
-
No other works shall be carried out under the activities that are working above. Chain block shall be used to the materials that are heavy in weight and large in size. Fence off the working area with barrier and notice / warning sign should be provided.
Note:
Probability or Likelihood Rating: Consequence Rating: Risk Level: