2 MGP
Systems with two Multi-Stage stainless steel pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 50
20
0 Imp. g.p.m. 10
30
40
20
0 U.S. g.p.m.
30
40
50
20
0 Imp. g.p.m. 10
30
40
20
30
40
150
MGP 203
40 H
150
m 30
MGP 204
40
ft
H
ft
m 30
100
20
100
20 50
50
10 0
10
0 m3/h 2 Q l/min 40 0
8
6
4 80
120
0
10 160
0
0 m3/h 2 Q l/min 40 0
8
6
4 80
120
72.1145.1
0 U.S. g.p.m. 60
20
0 Imp. g.p.m. 10
30
72.1145.2
40
20
0 U.S. g.p.m. 20
30
0
10 160
40
0
50
Imp. g.p.m.
40 20
60 40 150
MGP 205
50 H
MGP 403
40 H
150
m 40 30
ft
m 30
100
20
ft 100
50 10
20 50 10
0 m3/h 2 0 Q l/min 40
8
6
4 80
120
0
10 160
0 0
Q
m3/h l/min
4
8
0 16
12 200
100
72.1145.1
0 U.S. g.p.m. 20 50
0
Imp. g.p.m.
40 20
72.1145.3
60
0 U.S. g.p.m. 20
40
60
0
Imp. g.p.m.
40 20
60 40
150
MGP 404
40 H
m 30
MGP 405
50
ft
H
150
m 40
100
20
ft 100
30 50
10
20 50
0
0 0
Q
m3/h l/min
4
8 100
12 200
10
0 16 72.1145.4
0 0
Q
m3/h l/min
4
8 100
12 200
16 72.1145.4
516
2 MGP
Systems with two Multi-Stage stainless steel pumps Fixed speed pump or Variable speed pump (frequency converter)
Characteristic, dimensions and weights
B
L2 DN 2 H DN 1
h2
h1 4.93.315
m1 L1
BS2F Mains: 400V 3~ 3 ~ Motor: 400V 3~ BS2F 2MG BS2F 2MGP P 203 203 BS2F BS 2F 2MG 2MGP P 204 204 BS2F BS 2F 2MG 2MGP P 205 205 BS2F BS 2F 2MG 2MGP P 403 403 BS2F BS 2F 2MG 2MGP P 404 404 BS2F BS 2F 2MG 2MGP P 405 405
BSM2F Mains: 230V 1~ 1~ Motor: 230V 1~
Motor
kW HP BSM2F BSM2 F 2MGP 2MGPM M 203 203 0,4 ,45+ 5+0 0,4 ,45 5 0, 0,6+ 6+0, 0,6 6 BSM2 BS M2F F 2MGP 2MGPM M 204 204 0,55 0, 55+0 +0,5 ,55 5 0,75 0,75+0 +0,7 ,75 5 BSM2 BS M2F F 2MGP 2MGPM M 205 205 0, 0,75+0,75 1+1 BSM2 BS M2F F 2MGP 2MGPM M 403 403 0,55+0 0,55 +0,5 ,55 5 0, 0,75 75+0 +0,7 ,75 5 BSM2 BS M2F F 2MGP 2MGPM M 404 404 0, 0,75+0,75 1+1 BSM2 BS M2F F 2MGP 2MGPM M 405 405 1,1+1,1 1,5+1,5
* Maximum pumps flow at minimum set pressure of 2
BS1V1F
nd
Q max* l/min 155 15 5 160 16 0 160 230 23 0 220 220
Pres. switch setting bar 1,4 ,4÷2 ÷2,6 ,6 2,0÷ 2, 0÷3, 3,2 2 3,0÷4,5 1,2÷ 1, 2÷2, 2,4 4 2,4÷3,6 3, 0÷ 0÷4,5
bar 1,0 ,0÷2 ÷2,2 ,2 1,5÷ 1, 5÷2, 2,7 7 2,5÷4,0 0,9÷ 0, 9÷2, 2,1 1 2,0÷3,2 2, 5÷ 5÷4,0
Manifolds DN1 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 84 8 40 840 84 840 84 840 84 840 84 840 84
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Weight B2 B2 B kg 41 46 52 625 62 5 60 600 0 46 48 54
Vessel Mem. Vessel litre litre 24x2 100 24x2 100 24x2 100 24x2 100 80 200 80 200
pressure switch.
BSM1V1F
Mains: 400V 3~ 3~ Motor: 400V 3~
Mains: 230V 1~ 1Motor: ~ 230V 3~ and 230V 1~
BS1V1F 2MGP 203 BS1V1F 2MGP 204 BS1V1F 2MGP 205 BS1V1F 2MGP 403 BS1V1F 2MGP 404 BS1V1F 2MGP 405
BSM1V1F 2MGP 203 BSM1V1F 2MGP 204 BSM1V1F 2MGP 205 BSM1V1F 2MGP 403 BSM1V1F 2MGP 404 BSM1V1F 2MGP 405
BS2V
B2
Motor kW 0,45+0,45 0,55+0, 55 55 0,75+0,75 0,55+0, 55 55 0,75+0,75 1,1+1,1
Manifolds HP 0,6+0,6 0,75+0,75 1+1 0,75+0,75 1+1 1,5+1,5
DN D N1 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm H 1100 1100 1100 1100 1100 1100
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Vessel Weight Membrane B2 B2 B litre kg 24x2 41 24x2 46 24x2 52 625 62 5 60 600 0 24x2 46 24x2 48 24x2 54
BSM2V
Mains: 400V 3~ 3Motor: ~ 400V 3~
Mains: 230V 1~ 1Motor: ~ 230V 3~
BS2V 2MGP 203 BS2V 2MGP 204 BS2V 2MGP 205 BS2V 2MGP 403 BS2V 2MGP 404 BS2V 2MGP 405
BSM2V 2MGP 203 BSM2V 2MGP 204 BSM2V 2MGP 205 BSM2V 2MGP 403 BSM2V 2MGP 404 BSM2V 2MGP 405
Motor kW 0,45+0,45 0,55+0, 55 55 0,75+0,75 0,55+0, 55 55 0,75+0,75 1,1+1,1
Manifolds HP 0,6+0,6 0,75+0,75 1+1 0,75+0,75 1+1 1,5+1,5
517
DN D N1 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm H 1100 1100 1100 1100 1100 1100
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Vessel Weight Membrane B2 B2 B litre kg 24x2 41 24x2 46 24x2 52 625 62 5 60 600 0 24x2 46 24x2 48 24x2 54
51
2 MXP
Systems with two Multi-Stage stainless steel pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 50
20
0 Imp. g.p.m. 10
30
40
20
0 U.S. g.p.m.
30
40
20
0 Imp. g.p.m. 10
50
30
40
20
30
40
150
MXP 203
40 H
MXP 204
40
ft
m 30
150 H
100
20
ft
m 30
100
20 50
10 0
50 10
0 m3/h 2 0 Q l/min 40
8
6
4 80
0
10 160
120
0
0 m3/h 2 0 Q l/min 40
8
6
4 80
120
72.1145.1
0 U.S. g.p.m. 60
20
0 Imp. g.p.m. 10
30
72.1145.2
0 U.S. g.p.m. 20
40
20
30
0
10 160
40
50
0
Imp. g.p.m.
40 20
60 40 150
MXP 205
50 H
MXP 403
40 150
m 40
ft 100
30
H
ft
m 30
100
20 50 10
20 50 10
0 m3/h 2 Q l/min 40 0
8
6
4 80
0
10 160
120
0 0
Q
m3/h l/min
4
8
0 16
12 200
100
72.1145.1
0 U.S. g.p.m. 20 50
0
Imp. g.p.m.
40 20
72.1145.3
60
0 U.S. g.p.m. 20
40
60
0
Imp. g.p.m.
40 20
60 40
150
MXP 404
40 H
m 30
MXP 405
50
ft
H
100
20
150
m 40
ft 100
30 50
10
20
0
10
50 0 0
Q
m3/h l/min
4
8 100
12 200
0 16 72.1145.4
0 0
Q
m3/h l/min
4
8 100
12 200
16 72.1145.4
518
2 MXP
Systems with two Multi-Stage stainless steel pumps Fixed speed pump or Variable speed pump (frequency converter)
Characteristic, dimensions and weights
B
L2 DN 2 H DN 1
h2
h1 4.93.315
m1 L1
BS2F
BSM2F
Mains: 400V 3~ 3~ Motor: 400V 3~
Mains: 230V 1~ 1~ Motor: 230V 1~
BS2F 2M BS2F 2MXP XP 20 203 3 BS2F BS2 F 2MXP 204/A 204/A BS2F BS 2F 2M 2MXP XP 20 205 5 BS2F BS2 F 2MXP 403/A 403/A BS2F BS2 F 2MXP 404/A 404/A BS2F BS 2F 2M 2MXP XP 40 405 5
BSM2F BSM2 F 2MX 2MXPM PM 20 203 3 BSM2F BSM 2F 2MXPM 2MXPM 204/A BSM2 BS M2F F 2MX 2MXPM PM 20 205 5 BSM2F BSM 2F 2MXPM 2MXPM 403/A BSM2F BSM 2F 2MXPM 2MXPM 404/A BSM2 BS M2F F 2MX 2MXPM PM 40 405 5
Motor kW HP 0,,45+0,45 0,6+0, 6 0 0,55 0, 55+0 +0,5 ,55 5 0, 0,75 75+0 +0,7 ,75 5 0,75+0,75 0, 1+1 0,55 0, 55+0 +0,5 ,55 5 0, 0,75 75+0 +0,7 ,75 5 0,75+0,75 1+1 1,1+1,1 1,5+1,5
* Maximum pumps flow at minimum set pressure of 2
BS1V1F Mains: 400V 3~ 3 ~ Motor: 400V 3~ BS1V1F 2MXP 203 BS1V1F 2MXP 204/A BS1V1F 2MXP 205 BS1V1F 2MXP 403/A BS1V1F 2MXP 404/A BS1V1F 2MXP 405
BS2V Mains: 400V 3~ 3~ Motor: 400V 3~ BS2V 2MXP 203 BS2V 2MXP 204/A BS2V 2MXP 205 BS2V 2MXP 403/A BS2V 2MXP 404/A BS2V 2MXP 405
nd
B2
Q max* l/min 155 160 16 0 160 230 23 0 220 220
Pres. switch setting bar 1, 4÷ 4÷2,6 2,0÷ 2, 0÷3, 3,2 2 3,0÷4,5 1,5÷ 1, 5÷2, 2,7 7 2,4÷3,6 3, 0÷ 0÷4,5
bar 1,0÷2,2 1,5÷ 1, 5÷2, 2,7 7 2,5÷4,0 1,2÷ 1, 2÷2, 2,4 4 2,0÷3,2 3, 5÷ 5÷4,0
Manifolds DN1 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 84 8 40 840 84 840 84 840 84 840 84 840 84
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Weight B2 B2 B kg 41 46 48 625 62 5 60 600 0 46 48 54
Vessel Mem. Vessel litre litre 24x2 100 24x2 100 24x2 100 24x2 100 80 200 80 200
pressure switch.
BSM1V1F Mains: 230V 1~ 1~ 230V Motor: 3~ and 230V 1~ BSM1V1F 2MXP 203 BSM1V1F 2MXP 204/A BSM1V1F 2MXP 205 BSM1V1F 2MXP 403/A BSM1V1F 2MXP 404/A BSM1V1F 2MXP 405
Motor kW 0,45+0,45 0,55+0, 55 55 0,75+0,75 0,55+0, 55 55 0,75+0,75 1,1+1,1
Manifolds HP 0,6+0,6 0,75+0,75 1+1 0,75+0,75 1+1 1,5+1,5
DN D N1 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm H 1100 1100 1100 1100 1100 1100
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Vessel Weight Membrane B2 B2 B litre kg 24x2 41 24x2 46 24x2 48 625 62 5 60 600 0 24x2 46 24x2 48 24x2 54
BSM2V Mains: 230V 1~ 1~ Motor: 230V 3~ BSM2V 2MXP 203 BSM2V 2MXP 204/A BSM2V 2MXP 205 BSM2V 2MXP 403/A BSM2V 2MXP 404/A BSM2V 2MXP 405
Motor kW 0,45+0,45 0,55+0, 55 55 0,75+0,75 0,55+0, 55 55 0,75+0,75 1,1+1,1
Manifolds HP 0,6+0,6 0,75+0,75 1+1 0,75+0,75 1+1 1,5+1,5
519
DN D N1 G2 G 2 G2 G 2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm H 1100 1100 1100 1100 1100 1100
h1 151 151 151 151 151 151
h2 206 206 206 206 206 206
L1 793 793 793 793 793 793
L2 355 355 355 355 355 355
m1
235 23 5
Vessel Weight Membrane B2 B2 B litre kg 24x2 41 24x2 46 24x2 48 625 62 5 60 600 0 24x2 46 24x2 48 24x2 54
51
2 NM, NMD
Systems with two Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 10
U.S. g.p.m. 20
U.S. g.p.m.
30
10 Imp. g.p.m.
20
30
Imp. g.p.m. 10
20
36
20
30
44
NMD 20/110B/A
140
NMD 20/110A/A
40
30
100
H
ft
m
80
H
120
H m
H
30
100
ft
20 60 16 1
3 50
m 3/h 2 Q l/min
4
5
6 100
7
24 1
8
3 50
m 3/h Q l/min
4
5
6 100
7
72.955.1C
U.S. g.p.m.
20
30
Imp. g.p.m.
40
20
72.955.2C
U.S. g.p.m. 20
50
30
80 9 150
8
30
40
10 Imp. g.p.m. 20
40
30
56
35
180
110
NM 2/A/A
NMD 20/140BE
30
100
H
H
m
ft
25
50
160
H
H
ft
m
140
80 40 70
20 1
m /h 3 Q l/min 50 3
4
5
6 100
7
8
9 150
10
11
36 1
12 200
m3/h Q l/min
3 50
4
5
6 100
7
8
72.955.4C
72.955.3C
U.S. g.p.m. 20
30
U.S. g.p.m.
40
10 Imp. g.p.m. 20
30
NMD 20/140AE
20
50
30
40
NM 3/CE
130
200 120
H
H
35
m
ft
H
50
4
5
6 100
7
8
9 150
10
H ft
m
160
m3/h 3 Q l/min 50
40
40
1 ~
42 1
30
42
220
60
20
Imp. g.p.m.
40
68 3 ~
100
30
140 11
27 1
m 3/h 3 Q l/min 50
4
5
6 100
7
8
9 150
10
11
72.955.5C
U.S. g.p.m. 20
Imp. g.p.m.
120 10
9 150
30 20
40
50
30
60
40
50
90 12 200
72.955.6C
U.S. g.p.m. 20
70
Imp. g.p.m.
60
30 20
40
50
30
60
40
50
70 60
60
50 3 ~
NM 3/BE
150
NM 3/A/A
1 ~
H
40
H
50
ft
H
180
ft
H
m
m 100
30 26 1
m 3/h 4 Q l/min
6 100
8
10 150
12 200
14 16 250
140
40 36 1
18 300
520
m3/h 4 Q l/min
6 100
8
10 150
12 200
14 16 250
120 18 300
2 NM, NMD
Systems with two Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Characteristic, dimensions and weights B
L2
DN 2
H h2
DN 1
h1 3.93.042
m1 B2
L1
BS2F
BSM2F
Mains: 400V 3~ 3~ Motor: 400V 3~
Mains: 230V 1~ 1~ Motor: 230V 1~
BS2F 2NMD 20/110B/A BS2F 2NMD 20/110A/A BS2F 2NM 2/A/A BS2F 2NMD 20/140BE
BSM2F 2NMDM 20/110B/A BSM2F 2NMDM 20/110A/A BSM2F 2NMM 2/A/A BSM2F 2NMDM 20/140BE BSM2F 2NMDM 20/140AE
kW 0,45+0,45 0,75+0,75 0,75+0,75 1,1+1,1 1,5+1,5 BS2F 2NMD 20/140AE 1,5+1,5 BS2F 2NM 3/CE BSM2F 2NMM 3/CE 1,1+1,1 BSM2F 2NMM 3/BE 1,5+1,5 BS2F 2NM 3/BE 1,5+1,5 BS2F 2NM 3/A/A 2,2+2,2 Maximum pumps flow at minimum set pressure of 2 nd *
BS1V1F
Q max* HP l/min 0,6+0,6 120 1+1 130 1+1 200 1,5+1,5 160 2+2 160 2+2 180 1,5+1,5 200 2+2 200 2+2 270 3+3 280 pressure switch.
Motor
Mains: 230V 1~ 1~ Motor: 230V 3~ and 230V 1~
BS1V1F 2NMD 20/110B/A BS1V1F 2NMD 20/110A/A BS1V1F 2NM 2/A/A BS1V1F 2NMD 20/140BE
BSM1V1F 2NMD 20/110B/A BSM1V1F 2NMD 20/110A/A BSM1V1F 2NM 2/A/A BSM1V1F 2NMD 20/140BE BSM1V1F 2NMD 20/140AE BSM1V1F 2NM 3/CE BSM1V1F 2NM 3/BE
BS1V1F 2NM 3/BE BS1V1F 2NM 3/A/A
BS2V
Mains: 230V 1~ 1~ Motor: 230V 3~
BS2V 2 NMD 20/110B /A BS2V 2 NMD 20/110A /A BS2V 2NM 2/A/A BS2V 2NMD 20/140BE
BSM 2V 2N MD 2 0/110B/A BSM 2V 2N MD 2 0/110A/A BSM2V 2NM 2/A/A BSM2V 2NMD 20/140BE BSM2V 2NMD 20/140AE
BS2V 2NM 3/BE BS2V 2NM 3/A/A
bar 1,7÷2,7 2,4÷3,6 1 ,7÷2,7 3,2÷4,7 3,7÷5,0 4,7÷6,0 2,2÷3,2 2,7÷3,7 2,9÷4,2 3,7÷5,0
DN 1 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 8 40 8 40 8 40 8 40 840 8 40 8 40 8 40 8 40 8 40
h1 129 129 129 146 146 146 146 146 146 146
h2 277 277 295 295 295 295 325 325 325 325
L1 670 670 620 670 670 670 650 650 650 650
L2 315 315 262 320 320 320 267 267 267 267
m1
B2
B
235
625
600
Weight kg 51 55 54 72 75 77 71 75 76 78
Vessel Mem. Vessel litre litre 24x2 100 60 100 80 200 80 200 100 200 100 200 100 200 100 300 100 300 200 300
Motor kW 0,45+0,45 0,75+0,75 0,75+0,75 1,1+1,1 1,5+1,5 1,5+1,5 1,1+1,1 1,5+1,5 1,5+1,5 2,2+2,2
Manifolds HP 0,6+0,6 1+1 1+1 1,5+1,5 2+2 2+2 1,5+1,5 2+2 2+2 3+3
DN1 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 8 40 8 40 8 40 8 40 840 8 40 8 40 8 40 8 40 8 40
h1 129 129 129 146 146 146 146 146 146 146
h2 277 277 295 295 295 295 325 325 325 325
L1 670 670 620 670 670 670 650 650 650 650
L2 315 315 262 320 320 320 267 267 267 267
m1
B2
B
235
625
600
Vessel Weight Membrane litre kg 24x2 51 24x2 55 24x2 54 24x2 72 24x2 75 24x2 77 24x2 71 24x2 75 24x2 76 24x2 78
BSM2V
Mains: 400V 3~ 3~ Motor: 400V 3~
BS2V 2NMD 20/140AE BS2V 2NM 3/CE
bar 2,0÷3,0 2,8÷4,0 2,0÷3,0 3,4÷4,9 4,0÷5,3 5,0÷6,3 2,5÷3,5 3,0÷4,0 3,2÷4,5 4,0÷5,3
Manifolds
BSM1V1F
Mains: 400V 3~ 3~ Motor: 400V 3~
BS1V1F 2NMD 20/140AE BS1V1F 2NM 3/CE
Pres. switch setting
BSM2V 2NM 3/CE BSM2V 2NM 3/BE
Motor kW 0,45+0,45 0,75+0,75 0,75+0,75 1,1+1,1 1,5+1,5 1,5+1,5 1,1+1,1 1,5+1,5 1,5+1,5 2,2+2,2
Manifolds HP 0,6+0,6 1+1 1+1 1,5+1,5 2+2 2+2 1,5+1,5 2+2 2+2 3+3
521
DN1 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 8 40 8 40 8 40 8 40 840 8 40 8 40 8 40 8 40 8 40
h1 129 129 129 146 146 146 146 146 146 146
h2 277 277 295 295 295 295 325 325 325 325
L1 670 670 620 670 670 670 650 650 650 650
L2 315 315 262 320 320 320 267 267 267 267
m1
B2
B
235
625
600
Vessel Weight Membrane litre kg 24x2 51 24x2 55 24x2 54 24x2 72 24x2 75 24x2 77 24x2 71 24x2 75 24x2 76 24x2 78
51
2 NM, NMD
Systems with two Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 46
40
0 Imp g.p.m.
60
80
40
100
60
120
80
0 U.S. g.p.m.
100
0 Imp g.p.m.
60
80
40
100
60
120
80
100
200 180
40
H
45
ft
150 ft
140
140
160
30
120 0 m3/h 5 Q l/min 100 0
10
15
20
200
300
25 400
160
H m
H
H m
40 38
28
130 0 m3/h 5 Q l/min 100 0
10
15
20
200
300
25 400
50
0 Imp g.p.m.
100 50
0 U.S. g.p.m.
150 100 200
60
2NM 25/20S/A
66
0 Imp g.p.m.
40
60
20
80
40
60
2NMD 25/190C/A
60
H
28
72.956.2C
72.956.1C
0 U.S. g.p.m.
200 H
180
m
H ft 160
50
H
180 ft
m 50
160
140 40
140 40 120
120 34
0 m3/h Q l/min 0
10
20 200
30
36 600
400
34
0 m3/h Q l/min 0
5
10
15
100
20
200
300 72.956.4C
72.956.3C
0 U.S. g.p.m. 80
40
0 Imp g.p.m. 20
60
0 U.S. g.p.m. 20
80
40
40
0 Imp g.p.m. 20
60 260
2NMD 25/190B/A
H
240
m 70
60 40
100 m
220 ft
90
60
2NMD 25/190A/A
H
H
80
320 H
300 ft 280
200
60
180 50 46
170
2NM 25/20A/A
50
2NM 25/20B/A
24
40
160 0 m 3/h Q l/min 0
5
10 100
15 200
20
80
260 240
70
300
0 m3/h Q l/min 0
5
10 100
15 200
20 300 72.956.6C
72.956.5C
522
2 NM, NMD
Systems with two Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Characteristic, dimensions and weights
B
L2
DN 2
H h2
DN 1
h1 3.93.042
m1 L1
B2
BS2F Q Pres. switch setting max* kW HP l/min bar bar 2,2+2,2 3+3 400 3,0÷4,0 2,7÷3,7 BS2F 2NM 25/20B/A 3+3 4+4 440 3,8÷4,8 3,5÷4,5 BS2F 2NM 25/20A/A 4+4 5,5+5,5 560 4,0÷5,5 3,5÷5,0 BS2F 2NM 25/20S/A 2,2+2,2 3+3 280 4,3÷5,8 3,8÷5,3 BS2F 2NMD 25/190C/A 3+3 4+4 300 5,0÷7,0 4,5÷6,5 BS2F 2NMD 25/190B/A 4+4 5,5+5,5 320 7,5÷9,0 7,0÷8,5 BS2F 2NMD 25/190A/A nd * Maximum pumps flow at minimum set pressure of 2 pressure switch. Mains: 400V 3~ 3~ Motor: 400V 3~
Motor
Manifolds DN 1 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2
DN2 H G2 840 G2 840 G2 840 G2 840 G2 840 G2 840
mm h1 160 160 160 175 175 175
h2 330 330 330 330 330 330
L1 725 725 725 760 760 760
L2 373 373 373 407 407 407
m1
B2
235
625
Weight B kg 87 106 114 600 108 123 132
Vessel Mem. Vessel litre litre 300 500 500 800 500 800 200 300 200 300 300 500
BS1V1F Mains: 400V 3~ 3~ Motor: 400V 3~
Motor
BS1V1F 2NM 25/20B/A BS1V1F 2NM 25/20A/A BS1V1F 2NM 25/20S/A BS1V1F 2NMD 25/190C/A BS1V1F 2NMD 25/190B/A BS1V1F 2NMD 25/190A/A
kW 2,2+2,2 3+3 4+4 2,2+2,2 3+3 4+4
Manifolds
HP 3+3 4+4 5,5+5,5 3+3 4+4 5,5+5,5
DN1 G 21/2 G 21/2 G 21/2 G 21/2 G 21/2 G 21/2
DN2 H G2 840 G2 840 G2 840 G2 840 G2 840 G2 840
mm h1 160 160 160 175 175 175
h2 330 330 330 330 330 330
L1 725 725 725 760 760 760
L2 373 373 373 407 407 407
m1
B2
235
625
Vessel Weight Membrane B litre kg 24x2 87 24x2 106 24x2 114 600 108 24x2 24x2 123 24x2 132
BS2V Mains: 400V 3~ 3~ Motor: 400V 3~
BS2F 2NM 25/20B/A BS2F 2NM 25/20A/A BS2F 2NM 25/20S/A BS2F 2NMD 25/190C/A BS2F 2NMD 25/190B/A BS2F 2NMD 25/190A/A
Motor
kW 2,2+2,2 3+3 4+4 2,2+2,2 3+3 4+4
Manifolds
HP 3+3 4+4 5,5+5,5 3+3 4+4 5,5+5,5
DN1 G 21/2 G 21/2 G 21/2 G 21/2 G 21/2 G 21/2
523
DN2 H G2 840 G2 840 G2 840 G2 840 G2 840 G2 840
mm h1 160 160 160 175 175 175
h2 330 330 330 330 330 330
L1 725 725 725 760 760 760
L2 373 373 373 407 407 407
m1
235
B2
625
Vessel Weight Membrane B litre kg 24x2 87 24x2 106 24x2 114 600 108 24x2 24x2 123 24x2 132
51
2 NGL, NG
Systems with two self-priming Jet pumps Fixed speed pump
Coverage chart 0
U.S. g.p.m.
10
0
Imp. g.p.m.
20 10
50
U.S. g.p.m. 10
0
Imp. g.p.m.
20
150
m 40
30
10
20
50
NGL 2
H
0
NGL 3/A
H
150
m 40
ft
ft 100
30
100
30 20
20
50
50 10 0 m3/h 1 Q l/min 20 0
2
3
4
40
10
5
60
80
0 m3/h Q 0 l/min 20
2
3
4
40
5 80
60
6 100
72.1146.1
0 U.S. g.p.m.
20
30
0 Imp. g.p.m. 10
72.1146.2
0 U.S. g.p.m.
40
20
15
20
10
25
15
20
60
NGL 4/A
H
10
0 Imp. g.p.m.
30
50
7
150
m 40
H
150
40
100
30
NG 3/A
m
ft
H
ft 100
20 50 10
m3/h 2 0 Q l/min 0
4
6 100
50
8
20
10 150
0 m3 /h 1 Q 0 l/min 20
2
3
4
40
5 80
60
6 100
72.1146.3
0 U.S. g.p.m. 10 0 Imp. g.p.m.
20 10
72.954.3C
0 U.S. g.p.m.
30
20
30
0 Imp. g.p.m. 10
20
40
20
30
70
50 150 H
H
NG 4/A
m
200
NG 5/16E
m
H
H
ft
ft
50
100
30
150 40
15
0 m3 /h Q l/min 0
2
4
6
40
8
80
50
30
120
0 m3 /h 2 Q 0 l/min
4
6 100
50
150 72.954.5C
72.954.4C
0 U.S. g.p.m.
30
0 Imp. g.p.m. 20
40
50
30
40
60
70
50
0 U.S. g.p.m.
80
60
30
0 Imp. g.p.m. 20
70
60
40 30
50 40
60
70
50
80
60
70
60
H
NG 6/22E
m
H
H
3 1
3 1 0 m3 /h 0 Q l/min
5 100
10 200
40
100
15
150
m
ft 30
NG 7/22/A
50
150
40
20
100 10
8
H
ft 30
20 300 72.954.6C
0 m3 /h 0 Q l/min
5 100
10
100 20
15 200
300 72.954.7C
524
2 NGL, NG
Systems with two self-priming Jet pumps Fixed speed pump
Characteristic, dimensions and weights B
L2
DN 2
H DN 1
h2
h1 3.93.044
m1 B2
L1
BS2F
BSM2F
Mains: 400V 3~ 3~ Motor: 400V 3~
Mains: 230V 1~ Motor: 230V 1~
BS2F 2NGL 2 BS2F 2NGL 3/A BS2F 2NGL 4/A
BSM2F 2NGLM 2 BSM2F 2NGLM 3/A BSM2F 2NGLM 4/A
Motor kW HP 0,45+0,45 0,6+0,6 0,55+0,55 0,75+0,75 0,75+0,75 1+1
* Maximum pumps flow at minimum set pressure of 2
BS2F Mains: 400V 3~ 3~ Motor: 400V 3~ BS2F 2NG 3/A BS2F 2NG 4/A BS2F 2NG 5-16E BS2F 2NG 6-22E BS2F 2NG 7-22 /A
nd
Q max* l/min 70 90 160
Pres. switch setting bar 2,4÷3, 6 2,8÷4,0 2,2÷3,4
bar 2,0÷3,2 2,4÷3,6 1,8÷3,0
Manifolds DN1 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2
mm
H 840 840 840
h1 151 151 151
h2 206 206 206
L1 793 793 793
L2 355 355 355
m1 235
Weight B2 B kg 42 625 6 00 46 49
Vessel Mem. Vessel litre litre 24x2 100 24x2 100 24x2 100
Weight B kg 61 62 86 600 89 90 92
Vessel Mem. Vessel litre litre 24x2 100 24x2 100 24x2 100 100 200 100 200 200 300
pressure switch.
BSM2F Mains: 230V 1~ 1~ Motor: 230V 1~
Motor
kW HP BSM2F 2NGM 3/A 0,55+0,55 0,75+0, 75 BSM2F 2NGM 4/A 0,75+0,75 1+1 BSM2F 2NGM 5-16E 1,1+1,1 1, 5+1, 5 BSM2F 2NGM 6-22E 1,5+1,5 2+2 1,5+1,5 2+2 2,2+2,2 3+3
* Maximum pumps flow at minimum set pressure of 2
nd
Q max* l/min 95 130 140 290 290 300
Pres. switch setting bar 3, 0÷4,2 2,4÷3,6 3, 8÷5,3 3,0÷4,2 3,2÷4,5 3,8÷5,3
bar 2, 5÷3,7 2,0÷3,2 3, 4÷4,9 2,5÷3,7 2,8÷4,0 3,4÷4,9
Manifolds DN 1 G2 G2 G 21/2 G 21/2 G 21/2 G 21/2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 8 40 8 40 8 40 8 40 8 40 8 40
h1 184 184 200 200 200 200
h2 188 188 202 202 202 202
L1 775 775 935 935 935 935
L2 345 345 470 470 470 470
m1
B2
235
625
pressure switch.
51
525
2 NGX
Systems with two self-priming Jet pumps Fixed speed pump
Coverage chart
0
U.S. g.p.m.
0
Imp. g.p.m.
10
20 10
50
U.S. g.p.m. 10
0
Imp. g.p.m.
20
150
m 40
30
10
20
50
NGX 2
H
0
NGX 3
H
150
m 40
ft
ft
100
30
20
100
30
20 50
10 0 m3/h 1 Q l/min 20 0
2
3
4
40
50 10
5
60
80
0 m3/h Q 0 l/min 20
2
3 40
4 60
5 80
6 100
72.1146.1
0 U.S. g.p.m.
20
0 Imp. g.p.m.10
30 20
7 72.1146.2
40 30
50
NGX 4
H
150
m 40
ft 100
30
20 50 10
m3/h 2 0 Q l/min 0
4
6 100
50
8
10 150 72.1146.3
0 U.S. g.p.m.
20
0 Imp. g.p.m. 10
30 20
0 U.S. g.p.m.
40
30
0 Imp. g.p.m. 20
30
60
40 30
50 40
60
70
50
80
60
70
60
H
H
NGX 5/16
m
150 H
40
NGX 6/22
m
150 H
40
ft 100
30 20
ft
0 m3 /h 2 Q 0 l/min
4 50
6 100
8
20
10 150 72.1146.4
100
30
0 m3 /h Q 0 l/min
5 100
10
15 200
20 300 72.1146.5
526
2 NGX
Systems with two self-priming Jet pumps Fixed speed pump
Characteristic, dimensions and weights B
L2 DN 2 H DN 1
h2
h1 4.93.315
m1 L1
BS2F Mains: 400V 3~ 3~ Motor: 400V 3~ BS2F 2NGX 2 BS2F 2NGX 3/A BS2F 2NGX 4/A BS2F 2NGX 5-16 BS2F 2NGX 6-22
B2
BSM2F Mains: 230V 1~ Motor: 230V 1~
Motor
kW HP BSM2F 2NGXM 2 0,45+0,45 0,6+0, 6 BSM2F 2NGXM 3/A 0,55+0,55 0,75+0,75 BSM2F 2NGXM 4/A 0,75+0,75 1+1 BSM2F 2NGXM 5-16 1, 1+1,1 1,5+1, 5 BSM2F 2NGXM 6-22 1,5+1,5 2+2
* Maximum pumps flow at minimum set pressure of 2
nd
Q max* l/min 70 90 160 140 280
Pres. switch setting bar 2, 4÷3,6 2,8÷4,0 2,2÷3,4 3, 4÷4,9 3,0÷4,2
bar 2,0÷3,2 2,4÷3,6 1,8÷3,0 3,0÷4,5 2,5÷3,7
Manifolds DN1 G2 G2 G2 G2 G2
DN2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2
mm
H 840 840 840 840 840
h1 151 151 151 187 187
h2 206 206 206 212 212
L1 793 793 793 836 836
L2 355 355 355 380 380
m1
235
Weight B2 B kg 42 46 625 6 00 49 61 65
Vessel Mem. Vessel litre litre 24x2 100 24x2 100 24x2 100 24x2 100 100 200
pressure switch.
51
527
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 10 U.S. g.p.m. 30 40 50 10 Imp. g.p.m.
70
30 40 50
100 100
200
300
150 200
800
400 500
300
400 500
700
200
60
H
ft 50 150 40
1-3MXH
H m
100
30
20 50 10
0 2
m3/h Q l/min
5 100
10 15 20 30 40 50 150 200 300 400 500 1000
100 150 200 2000 3000 72.949.C
Operation BS 1-6F
Electrical control boards: - with microprocessor for fixed speed pump units (see page 486). Motor starting is D.O.L. up to 5,5 kW and Y/∆ for power rating 7,5 kW. - with frequency converter for variable speed pump units (see page 487).
Pressure boosting sets with 1 to 6 fixed speed pump. Sets with 4,5 and 6 pumps on request. Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the microprocessor alternates the starts.
The unit includes one pressure gauge and three adjustable differential pressure switches or pressure transducer (for sets with frequency converter).
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with frequency converter into the control panel) and from 1 to 5 fixed speed pumps Sets with 4,5 and 6 pumps on request. According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water quantity required at the set pressure. BS1-6V
Applications To supply water in civil and industrial buildings. As pressure boosting pump to increase water pressure when needed (follow local rules).
Pressure boosting sets with 1 to 6 variable speed pumps (with frequency converter into the control panel). Sets with 4,5 and 6 pumps on request. Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set pressure.
Motors 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with frequency converter. - Three-phase 230/400V ± 10% up to 3 kW; 400/690V ± 10% for 4 kW to 7,5 kW; - Single-phase 230 V ± 10%, with thermal protector. Insulation class F. Protection IP 54. Constructed in accordance with: IEC 60034. Other voltages and frequencies on request.
Construction - Automatic pressure boosting plant consisting of 1 horizontal multi-stage close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.
Vessels on request - Automatic pressure boosting plant consisting of 2 to 6 horizontal multistage pumps complete with ball, non return valve on the suction side and ball valves on the delivery side. Suction and delivery manifolds are in AISI 304. Connections are located on the delivery manifold for the installation of 20 litres cylindrical vessels: - 2 vessels for 2-pump sets. - 3 vessels for 3-pump sets.
When installing the unit, connect in the delivery section to a diaphragm or galvanised tank. The recommended sized are shown in the following page.
Special features on request Pressure boosting sets with 4,5 and 6 pumps.
528
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0
70
Imp. g.p.m.
15
30
45
70
1-3MXH 2
60
200
0
30
Imp. g.p.m.
60
1-3MXH 4
60
200
50
50 H
H
150
m 40
ft
ft 5
5
100
30
100
30
4
4
20
50
2
3
m /h
0 0
0
Q
3
l/min
60
Imp g.p.m.
0 15
12
120
180
50
0
150
4
150
0
300
100
200
280
1-3MXH 16 200
H
50
6
150
m
5
40
100
ft 4
30
3
20
l/min
24
18
60
ft
5
30
12
70
150 40
Q
6
0 Imp g.p.m.
200
1-3MXH 8
50
m3/h
0
240
100
60 H m
50
2
10
9
6
3
20
3
10
150
6
m 40
6
100
3 2
20
50
10
2
50
10
0 0 0
0
m3/h Q
l/min
Imp. g.p.m.
20 200
300
200
30 400
300
600
400
m3/h
0
40
500
0
0
0 10
0
700
Q
l/min
0 Imp. g.p.m.
500
80
20
30
40
400
200
50
600
300
60
800
400
1000
500
600
70
80
1200
700
70 ft
70
1-3MXH 32 60
200
60 200
1-3MXH 48
H
m
H
ft
4
m
40
3
40 3
2
2
20
20
0 0 0
m 3/h Q
l/min 500
50
10 0
0 150
100
51
1
1
10
100
30
100
30
0 m3/h 30
60
90
120
150
180
0 210
0 l/min 500
1000
1500
2000
2500
3000
3500
Q
1000
1500
2000
2500
529
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F Mains: 400V 3~ Motor: 400V 3~ BS1F 1MXH 203E BS1F 1MXH 204/A BS1F 1MXH 205/A BS1F 1MXH 206/B BS1F 1MXH 403/A BS1F 1MXH 404/A BS1F 1MXH 405/B BS1F 1MXH 406 BS1F 1MXH 803 BS1F 1MXH 804 BS1F 1MXH 805/A BS1F 1MXH 1603/A BS1F 1MXH 1604/A BS1F 1MXH 1605/A BS1F 1MXH 1606/A BS1F 1MXH 3202/A BS1F 1MXH 3203/A BS1F 1MXH 3204/A BS1F 1MXH 4802/A BS1F 1MXH 4803/A
BSM1F Mains: 230V 1~ Motor: 230V 1~
Pres. switch 1 bar
Motor kW 0,45 0,55 0,75 1,1 0,55 0,75 1,1 1,5 1,1 1,5 1,8 1,8 3 3,7 4 4 5,5 7,5 5,5 7,5
BSM1F 1MXHM 203E BSM1F 1MXHM 204/A BSM1F 1MXHM 205/A BSM1F 1MXHM 206 BSM1F 1MXHM 403/A BSM1F 1MXHM 404/A BSM1F 1MXHM 405 BSM1F 1MXHM 406 BSM1F 1MXHM 803 BSM1F 1MXHM 804
HP 0,6 0,75 1 1,5 0,75 1 1,5 2 1,5 2 2,5 2,5 4 5 5,5 5,5 7,5 10 7,5 10
min 1,4 2,8 3,5 4 1,4 2,4 3,4 4 1,6 2,8 3,5 1,5 2,8 3,8 4,5 1,8 3,1 4,7 2,4 3
max 2,8 4 5 6 2,6 3,6 4,9 6 2,8 4 5 3 4 5,3 6,5 3 4,6 6,2 3,6 4,5
Maximum capacity * Q l/min
H m
Vessel Membrane litre
70 55 56 61 122 107 102 111 209 186 186 382 353 331 329 718 666 633 743 886
14 29 36 41 14 24 35 41 16 29 36 15 29 39 46 18 32 48 24 31
24 40 40 50 60 80 100 100 100 200 200 300 500 500 500 1000 1000 1500 1000 2000
Vessel 100 100 100 100 100 200 200 200 300 300 500 500 1000 1000 800 1500 2000 3000 2000 3000
litre
* Maximum pumps flow at minimum setting pressure switch.
BS2F Mains: 400V 3~ Motor: 400V 3~ BS2F 2MXH 203E BS2F 2MXH 204/A BS2F 2MXH 205/A BS2F 2MXH 206/B BS2F 2MXH 403/A BS2F 2MXH 404/A BS2F 2MXH 405/B BS2F 2MXH 406E BS2F 2MXH 803 BS2F 2MXH 804 BS2F 2MXH 805/A BS2F 2MXH 1603/A BS2F 2MXH 1604/A BS2F 2MXH 1605/A BS2F 2MXH 1606/A BS2F 2MXH 3202/A BS2F 2MXH 3203/A BS2F 2MXH 3204/A BS2F 2MXH 4802/A BS2F 2MXH 4803/A
BSM2F Alimentazione 230V 1~ Motore 230V 1~
Motor kW 0,45 x2 0,55 x2 0,75 x2 1,1 x2 0,55 x2 0,75 x2 1,1 x2 1,5 x2 1,1 x2 1,5 x2 1,8 x2 1,8 x2 3 x2 3,7 x2 4 x2 4 x2 5,5 x2 7,5 x2 5,5 x2 7,5 x2
BSM2F 2MXHM 203E BSM2F 2MXHM 204/A BSM2F 2MXHM 205/A BSM2F 2MXHM 206 BSM2F 2MXHM 403/A BSM2F 2MXHM 404/A BSM2F 2MXHM 405 BSM2F 2MXHM 406 BSM2F 2MXHM 803 BSM2F 2MXHM 804
* Maximum pumps flow at minimum setting pressure of 2
nd
HP 0,6 x2 0,75 x2 1 x2 1,5 x2 0,75 x2 1 x2 1,5 x2 2 x2 1,5 x2 2 x2 2,5 x2 2,5 x2 4 x2 5 x2 5,5 x2 5,5 x2 7,5 x2 10 x2 7,5 x2 10 x2
Pres. switch 1 bar
Pres. switch 2 bar
min 1,4 2,8 3,5 4 1,4 2,4 3,4 4 1,6 2,8 3,5 1,5 2,8 3,8 4,5 1,5 3 4 1,5 3
min 1 2,4 3 3,5 1 2 3 3,5 1,2 2,4 3 1,2 2,4 3,4 4 1,2 2,5 3,5 1,2 2,5
max 2,8 4 5 6 2,6 3,6 4,9 6 2,8 4 5 3 4 5,3 6,5 3 4,5 6 3 4,5
max 2,4 3,6 4,5 5,5 2,2 3,2 4,5 5,5 2,4 3,6 4,5 2,7 3,6 4,9 6 2,7 4 5,5 2,7 4
Maximum capacity * Q l/min
H m
Vessel Membrane litre
156 128 130 136 264 237 224 241 442 406 405 805 770 728 725 1594 1474 1404 1950 1946
10 24 31 36 10 20 31 36 12 24 31 12 24 35 41 13 27 43 15 25
24 40 40 50 60 80 100 100 100 200 200 300 500 500 500 1000 1000 1500 1000 2000
pressure switch.
BS3F Mains: 400V 3~ Motor: 400V 3~ BS3F 3MXH 203E BS3F 3MXH 204/A BS3F 3MXH 205/A BS3F 3MXH 206/B BS3F 3MXH 403/A BS3F 3MXH 404/A BS3F 3MXH 405/B BS3F 3MXH 406E BS3F 3MXH 803 BS3F 3MXH 804 BS3F 3MXH 805/A BS3F 3MXH 1603/A BS3F 3MXH 1604/A BS3F 3MXH 1605/A BS3F 3MXH 1606/A BS3F 3MXH 3202/A BS3F 3MXH 3203/A BS3F 3MXH 3204/A BS3F 3MXH 4802/A BS3F 3MXH 4803/A
Motor kW 0,45 x3 0,55 x3 0,75 x3 1,1 x3 0,55 x3 0,75 x3 1,1 x3 1,5 x3 1,1 x3 1,5 x3 1,8 x3 1,8 x3 3 x3 3,7 x3 4 x3 4 x3 5,5 x3 7,5 x3 5,5 x3 7,5 x3
HP 0,6 x3 0,75 x3 1 x3 1,5 x3 0,75 x3 1 x3 1,5 x3 2 x3 1,5 x3 2 x3 2,5 x3 2,5 x3 4 x3 5 x3 5,5 x3 5,5 x3 7,5 x3 10 x3 7,5 x3 10 x3
* Maximum pumps flow at minimum setting pressure of 3
Pres. switch 1 bar min 1,8 2,8 3,5 4 1,6 2,4 3,4 4 1,9 2,8 3,5 1,8 2,8 3,8 4,5 2 3,1 4,7 2 3 nd
max 2,8 4 5 6 2,6 3,6 4,9 6 2,9 4 5 3 4 5,3 6,5 3 4,6 6,2 3,2 4,5
Pres. switch 2 bar min 1,4 2,4 3 3,5 1,1 2 3 3,5 1,5 2,4 3 1,4 2,4 3,4 4 1,5 2,6 4,2 1,5 2,5
max 2,4 3,6 4,5 5,5 2,3 3,2 4,5 5,5 2,5 3,6 4,5 2,6 3,6 4,9 6 2,5 4,1 5,7 2,7 4
pressure switch.
530
Pres. switch 3 bar min 1 1,9 2,5 3 1 1,5 2,5 3 1 1,9 2,5 1 1,9 2,9 3,5 1 2,1 3,7 1 2
max 2 3,1 4 5 2 2,7 4 5 2 3,1 4 2,2 3,1 4,4 5,5 2 3,6 5,2 2,2 3,5
Maximum capacity * Q l/min
H m
Vessel Membrane litre
234 220 217 223 396 388 367 383 673 651 643 1237 1228 1180 1166 2470 2365 2270 3193 3141
10 19 25 31 10 15 25 31 10 19 25 10 19 30 36 10 21 38 10 20
24 40 40 50 60 80 100 100 100 200 200 300 500 500 500 1000 1000 1500 1000 2000
Vessel 100 100 100 100 100 200 200 200 300 300 500 500 1000 1000 800 1500 2000 3000 2000 3000
litre
Vessel 100 100 100 100 100 200 200 200 300 300 500 500 1000 1000 800 1500 2000 3000 2000 3000
litre
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS.. PUMPS Nos N. POMPE 1
2
3
PUMP TYPE TIPO POMPE
4
5
6 MXH 203E MXH 204/A MXH 205/A MXH 206/B MXH 403/A MXH 404/A MXH 405/B MXH 406E
BS1V
BS2V
BS3V
BS4V
BS5V
BS6V
BS1V1F
BS1V2F
BS1V3F
BS1V4F
BS1V5F
MXH 803 MXH 804 MXH 805/A
BSM1V1F*
MXH 1603/A
BSM2V**
MXH 1604/A MXH 1605/A MXH 1606/A MXH 3202/A MXH 3203/A MXH 3204/A MXH 4802/A MXH 4803/A
(*) SYSTEMS WITH: 1 variable speed pump three-phase motor 1 fixed speed pump single-phase motor Power supply to control panel 230 V single-phase
PP22 pompa ForPer each pump kW 0,45 0,55 0,75 1,1 0,55 0,75 1,1 1,5 1,1 1,5 1,8 1,8 3 3,7 4 4 5,5 7,5 5,5 7,5
HP 0,6 0,75 1 1,5 0,75 1 1,5 2 1,5 2 2,5 2,5 4 5 5,5 5,5 7,5 10 7,5 10
(**) Three-phase motor 230 V. Power supply to control panel: - 230 V three-phase - 230 V single-phase Frequency converter output is alwais 230 V three-phase.
51
531
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hv Hf DN 2
h2
DN1
h1
B2
m1
TYPE
Connection Collettori
mm
DN 1
DN 2
Hv
Hf
h1
h2
m1
B2
G 1 1/4
G1
1045
875
170
145
625
365
G 1 1/4
G1
1045
875
170
145
625
365
G 1 1/2
G1
1045
875
170
145
625
365
1045
875
175
195
625
365
BS.. 1MXH 203E BS.. 1MXH 204/A BS.. 1MXH 205/A
weight Peso kg -
BS.. 1MXH 206/B BS.. 1MXH 403/A BS.. 1MXH 404/A BS.. 1MXH 405/B BS.. 1MXH 406E BS.. 1MXH 803 BS.. 1MXH 804 BS.. 1MXH 805/A BS.. 1MXH 1603/A BS.. 1MXH 1604/A BS.. 1MXH 1605/A
G 1 1/2 G 1 1/2
BS.. 1MXH 1606/A
DN 2
h2
Hv Hf
DN 1
h1
m1
TYPE
B2
Connection Collettori
weight Peso
mm
DN 1
DN 2
Hv
Hf
h1
h2
m1
B2
65
50
1045
875
195
265
625
365
80
65
1145
1145
195
275
625
365
BS.. 1MXH 3202/A BS.. 1MXH 3203/A BS.. 1MXH 3204/A BS.. 1MXH 4802/A BS.. 1MXH 4803/A
532
kg
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights BS.. 2MXH 2,4,8
BS.. 2MXH 16 L2
B
B
DN 2
L2 DN 2 H
H
2 h
DN 1
DN 1
h2
1 h
h1
3.93.159
3.93.043
m1
m1 L1
Connection Collettori
TYPE BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS..
DN 1 G2 G2 G2 G2 G2 G2 G2 G2 G 21/2 G 21/2 G 21/2 G3 G3 G3 G3
2MXH 203E 2MXH 204/A 2MXH 205/A 2MXH 206/B 2MXH 403/A 2MXH 404/A 2MXH 405/B 2MXH 406E 2MXH 803 2MXH 804 2MXH 805/A 2MXH 1603/A 2MXH 1604/A 2MXH 1605/A 2MXH 1606/A
B2
L1
B2
DN 2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G 11/2 G2 G2 G2 G 21/2 G 21/2 G 21/2 G 21/2
mm H 840 840 840 840 840 840 840 840 840 840 840 985 985 985 985
h1 162 162 162 162 162 162 162 162 162 162 162 250 265 265 265
h2 202 202 202 202 202 202 202 202 208 208 208 295 295 295 295
L1 773 796 820 845 773 796 820 845 866 896 926 945 1045 1085 1120
L2 335 358 382 406 335 358 382 406 428 458 488 490 530 565 605
m1
B2
B
235
625
600
625
600
weight Peso kg 42 47 50 54 46 49 53 57 61 66 68 87 114 122 124
905 1040
L2
B DN 2
DN 1
2 h
H
1 h 3.93.155
m1
B2
L1
TYPE BS.. BS.. BS.. BS.. BS..
2MXH 3202/A 2MXH 3203/A 2MXH 3204/A 2MXH 4802/A 2MXH 4803/A
Collettori Connection DN 1 100 100 100 125 125
DN 2 80 80 80 100 100
mm H 1510 1510 1510 1510 1510
h1 285 285 285 285 285
h2 435 435 435 465 465
533
L1 1265 1270 1320 1380 1420
L2 565 615 660 665 725
weight Peso m1 1175 1175 1175 1175 1220
B2
B
800
750
kg 214 243 260 268 286
51
BS. MXH
Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights BS.. 2MXH 2,4,8
BS.. 2MXH 16
B
B
L2 DN 2 L2 DN 2 H
H
2 h
DN 1
DN 1
h2
1 h
h1
3.93.159
3.93.043
m1
m1
L1
B2
Collettori
TYPE BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS.. BS..
DN 1 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G 2 1/2 G3 G3 G3 DN 100 DN 100 DN 100 DN 100
3MXH 203E 3MXH 204/A 3MXH 205/A 3MXH 206/B 3MXH 403/A 3MXH 404/A 3MXH 405/B 3MXH 406E 3MXH 803 3MXH 804 3MXH 805/A 3MXH 1603/A 3MXH 1604/A 3MXH 1605/A 3MXH 1606/A
B2
L1
DN 2 G2 G2 G2 G2 G2 G2 G2 G2 G 21/2 G 21/2 G 21/2 DN 80 DN 80 DN 80 DN 80
mm H 840 840 840 840 840 840 840 840 840 840 840 985 985 985 985
h1 162 162 162 162 162 162 162 162 162 162 162 250 265 265 265
h2 202 202 202 202 202 202 202 202 208 208 208 295 295 295 295
L1 773 796 820 845 773 796 820 845 866 896 926 945 1045 1085 1120
L2 335 358 382 406 335 358 382 406 428 458 488 490 530 565 605
L2
m1
B2
B
235
1350
1200
1350
1200
Peso kg -
905 1040
B DN 2
H
DN 1
2 h
1 h 3.93.155
m1
B2
L1
TYPE BS.. BS.. BS.. BS.. BS..
3MXH 3202/A 3MXH 3203/A 3MXH 3204/A 3MXH 4802/A 3MXH 4803/A
Collettori DN 1 125 125 125 150 150
DN 2 100 100 100 125 125
mm H 1510 1510 1510 1510 1510
h1 285 285 285 285 285
534
h2 435 435 435 465 465
L1 1265 1270 1320 1380 1420
L2 565 615 660 665 725
Peso m1 1175 1175 1175 1175 1220
B2
B
1250
1200
kg -
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 5 U.S. g.p.m. 10 4
20
30
5 Imp. g.p.m. 10
20
40 50 30
40 50
100
200 100
120 100
300
H
m
200
1-3 MXV-B 50 H
40
ft 100
30
20
15
1
3 m3/h 2 20 l/min 30 40 50 Q
4
5 100
10 150 200
20 30 300 400 500
40 50
50
72.1002/1
Operation BS 1-6F
Electrical control boards: - with microprocessor for fixed speed pump units (see page 486). Motor starting is D.O.L. up to 5,5 kW and Y/∆ for power rating 7,5 kW. - with frequency converter for variable speed pump units (see page 487).
Pressure boosting sets with 1 to 6 fixed speed pump. Sets with 4,5 and 6 pumps on request. Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the microprocessor alternates the starts.
The unit includes one pressure gauge and three adjustable differential pressure switches or pressure transducer (for sets with frequency converter).
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with frequency converter into the control panel) and from 1 to 5 fixed speed pumps Sets with 4,5 and 6 pumps on request. According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water quantity required at the set pressure. BS1-6V
Applications To supply water in civil and industrial buildings. As pressure boosting pump to increase water pressure when needed (follow local rules).
Pressure boosting sets with 1 to 6 variable speed pumps (with frequency converter into the control panel). Sets with 4,5 and 6 pumps on request. Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set pressure.
Motors 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with frequency converter. - Three-phase 230/400V ± 10% up to 3 kW; 400/690V ± 10% for 4 kW to 7,5 kW; - Single-phase 230 V ± 10%, with thermal protector. Insulation class F. Protection IP 54. Constructed in accordance with: IEC 60034. Other voltages and frequencies on request.
Construction - Automatic pressure boosting plant consisting of 1 vertical multi-stage close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.
Vessels on request - Automatic pressure boosting plant consisting of 2 to 6 vertical multistage close coupled pumps complete with ball, non return valve on the suction side and ball valves on the delivery side. Suction and delivery manifolds are in AISI 304. Connections are located on the delivery manifold for the installation of 20 litres cylindrical vessels: - 2 vessels (for 2MXV-B 25-32-40), 1 vessel (for 2MXV-B 50). - 3 vessels (for 3MXV-B 25-32-40), 2 vessels (for 3MXV-B 50).
When installing the unit, connect in the delivery section to a diaphragm or galvanised tank. The recommended sized are shown in the following page.
Special features on request Pressure boosting sets with 4,5 and 6 pumps.
540
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0
U.S. g.p.m.
0
Imp. g.p.m.
20
30 20
40
50
30
60
40
50
140
0
U.S. g.p.m.
30
0
Imp. g.p.m.
40 30
50
60
40
70
50
80
60
90 70
100 80
110 90
140
1-3MXV-B 25
1-3MXV-B 32
400
120
400
120
100
100 300
H
10
80
300 80
ft
H m
8 7
7
6
6
200
5
40
4
4
100
20
0
8
60
5
40
ft
H m
200
60
H
10
100
20
0 0
m 3/h Q l/min
3 50
6 100
9 150
0 15 250
12 200
0
0 0
m 3/h Q l/min
6 100
12 200
18 300
24 400
72.951.1C
0 U.S. g.p.m. 40 0 Imp. g.p.m.
60 40
80 60
100 80
120
140
100
160
120
27
0
72.951.2C
180
140
0
U.S. g.p.m.
0
Imp. g.p.m.
140
140
100
200 100
150
300 200
250
1-3MXV-B 50
1-3MXV-B 40
400
120
400
120 Series cannot be sold in the EU
ft 100
100
10
10
300
300
9 H
80
8
H m
80
ft
8 H
7
60
7
m
200
6
6
5 40
ft
5
40
4
4 100
100
3
20
20
0
200
51 0 m 3/h 6 0 Q l/min
12 200
18 300
24 400
30 500
36 600
0
0 42 700 72.951.3C
0 0
Q
m 3/h 15 300 l/min
30
45 600
60 900
75 1200 72.953.1C
541
0
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F Mains: 400V 3~ Motor: 400V 3~
BSM1F Mains: 230V 1~ Motor: 230V 1~
BS1F 1MXV-B 25-204
BSM1F 1MXV-BM 25-204
BS1F 1MXV-B 25-205
BSM1F 1MXV-BM 25-205
BS1F 1MXV-B 25-206 BS1F 1MXV-B 25-207
BSM1F 1MXV-BM 25-206 BSM1F 1MXV-BM 25-207
BS1F 1MXV-B 25-208
BSM1F 1MXV-BM 25-208
BS1F 1MXV-B 25-210 BS1F 1MXV-B 32-404
BSM1F 1MXV-BM 25-210 BSM1F 1MXV-BM 32-404
BS1F 1MXV-B 32-405
BSM1F 1MXV-BM 32-405
BS1F 1MXV-B 32-406 BS1F 1MXV-B 32-407
BSM1F 1MXV-BM 32-406 BSM1F 1MXV-BM 32-407
BS1F 1MXV-B 32-408/A BS1F 1MXV-B 32-410/A BS1F 1MXV-B 40-804
Pres. switch 1 bar
Motor
BSM1F 1MXV-BM 40-804
BS1F 1MXV-B 40-805/A BS1F 1MXV-B 40-806/A BS1F 1MXV-B 40-807/A BS1F 1MXV-B 40-808/A BS1F 1MXV-B 40-810/A BS1F 1MXV-B 50-1803/A BS1F 1MXV-B 50-1804/A BS1F 1MXV-B 50-1805/A BS1F 1MXV-B 50-1806/A BS1F 1MXV-B 50-1807/A BS1F 1MXV-B 50-1808/A BS1F 1MXV-B 50-1809/A BS1F 1MXV-B 50-1810/A
kW 0,75 0,75 1,1 1,1 1,5 1,5 1,1 1,1 1,5 1,5 2,2 2,2 1,5 2,2 2,2 3 3 3,7 2,2 3 3,7 4 5,5 5,5 7,5 7,5
HP 1 1 1,5 1,5 2 2 1,5 1,5 2 2 3 3 2 3 3 4 4 5 3 4 5 5,5 7,5 7,5 10 10
min 2,5 3,5 4 5 6 6,5 2,3 3,4 4 5 6 6 2,5 3,5 4 5 6 8 1,5 2,5 3,5 4 5 6 7 8
max 4 5 6 7 8 9,5 3,8 4,9 6 7 8 9 4 5 6 7 8 10 3 4 5 6 7 8 9 10
Maximum capacity * Q
l/min
62 56 59 55 51 60 114 103 105 99 93 114 214 211 211 208 199 188 395 373 357 359 358 341 343 333
H
m
25 36 41 51 61 66 23 35 41 51 61 61 25 36 41 51 61 82 15 25 36 41 51 61 71 82
Vessel Membrane litre
Vessel
40 50 50 50 60 60 80 100 100 100 150 150 200 300 300 300 300 500 300 500 500 500 750 750 1000 1000
100 100 100 100 100 100 100 100 100 300 300 300 300 500 500 500 500 800 500 800 1000 800 1000 1000 2000 2000
litre
* Maximum pumps flow at minimum setting pressure switch.
BS2F Mains: 400V 3~ Motor: 400V 3~
BSM2F Alimentazione 230V 1~ Motore 230V 1~
BS2F 2MXV-B 25-204
BSM2F 2MXV-BM 25-204
BS2F 2MXV-B 25-205 BS2F 2MXV-B 25-206
BSM2F 2MXV-BM 25-205 BSM2F 2MXV-BM 25-206
BS2F 2MXV-B 25-207
BSM2F 2MXV-BM 25-207
BS2F 2MXV-B 25-208 BS2F 2MXV-B 25-210
BSM2F 2MXV-BM 25-208 BSM2F 2MXV-BM 25-210
BS2F 2MXV-B 32-404
BSM2F 2MXV-BM 32-404
BS2F 2MXV-B 32-405 BS2F 2MXV-B 32-406
BSM2F 2MXV-BM 32-405 BSM2F 2MXV-BM 32-406
BS2F 2MXV-B 32-407
BSM2F 2MXV-BM 32-407
Motor kW 0,75 x2 0,75 x2 1,1 x2 1,1 x2 1,5 x2 1,5 x2 1,1 x2 1,1 x2 1,5 x2 1,5 x2 2,2 x2 2,2 x2 1,5 x2 2,2 x2 2,2 x2 3 x2 3 x2 3,7 x2 2,2 x2 3 x2 3,7 x2 4 x2 5,5 x2 5,5 x2 7,5 x2 7,5 x2
BS2F 2MXV-B 32-408/A BS2F 2MXV-B 32-410/A BS2F 2MXV-B 40-804
BSM2F 2MXV-BM 40-804
BS2F 2MXV-B 40-805/A BS2F 2MXV-B 40-806/A BS2F 2MXV-B 40-807/A BS2F 2MXV-B 40-808/A BS2F 2MXV-B 40-810/A BS2F 2MXV-B 50-1803/A BS2F 2MXV-B 50-1804/A BS2F 2MXV-B 50-1805/A BS2F 2MXV-B 50-1806/A BS2F 2MXV-B 50-1807/A BS2F 2MXV-B 50-1808/A BS2F 2MXV-B 50-1809/A BS2F 2MXV-B 50-1810/A
* Maximum pumps flow at minimum setting pressure of 2
nd
HP 1 x2 1 x2 1,5 x2 1,5 x2 2 x2 2 x2 1,5 x2 1,5 x2 2 x2 2 x2 3 x2 3 x2 2 x2 3 x2 3 x2 4 x2 4 x2 5 x2 3 x2 4 x2 5 x2 5,5 x2 7,5 x2 7,5 x2 10 x2 10 x2
Pres. switch 1 bar min max 2,5 4 3,5 5 4 6 5 7 6 8 6,5 9,5 2,3 3,8 3,4 4,9 4 6 5 7 6 8 6 9 2,5 4 3,5 5 4 6 5 7 6 8 8 10 1,5 3 2,5 4 3,5 5 4 6 5 7 6 8 7 9 8 10
pressure switch.
542
Pres. switch 2 bar min max 2,2 3,7 3 4,5 3,5 5,5 4,5 6,5 5,5 7,5 6 9 1,8 3,3 3 4,5 3,5 5,5 4,5 6,5 5,5 7,5 5,5 8,5 2,2 3,7 3 4,5 3,5 5,5 4,5 6,5 5,5 7,5 7,5 9,5 1,2 2,7 2,2 3,7 3 4,5 3,5 5,5 4,5 6,5 5,5 7,5 6,5 8,5 7,5 9,5
Maximum capacity * Q
l/min
135 128 130 122 113 128 253 226 232 218 205 239 435 438 435 434 418 399 822 784 777 771 764 733 731 711
H
m
22 31 36 46 56 61 18 31 36 46 56 56 22 31 36 46 56 76 12 22 31 36 46 56 66 76
Vessel Membrane litre 40 50 50 50 60 60 80 100 100 100 150 150 200 300 300 300 300 500 300 500 500 500 750 750 1000 1000
Vessel litre 100 100 100 100 100 100 100 100 100 300 300 300 300 500 500 500 500 800 500 800 1000 800 1000 1000 2000 2000
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS3F Mains: 400V 3~ Motor: 400V 3~
Pres. switch 1 bar min max 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 6,5 9,5 2,3 3,8 3,4 4,9 4,4 5,9 5,5 7 6,5 8 6 9 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 8 10 1,8 3 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 7 9 8 10
Motor kW 0,75 x3 0,75 x3 1,1 x3 1,1 x3 1,5 x3 1,5 x3 1,1 x3 1,1 x3 1,5 x3 1,5 x3 2,2 x3 2,2 x3 1,5 x3 2,2 x3 2,2 x3 3 x3 3 x3 3,7 x3 2,2 x3 3 x3 3,7 x3 4 x3 5,5 x3 5,5 x3 7,5 x3 7,5 x3
BS3F 3MXV-B 25-204 BS3F 3MXV-B 25-205 BS3F 3MXV-B 25-206 BS3F 3MXV-B 25-207 BS3F 3MXV-B 25-208 BS3F 3MXV-B 25-210 BS3F 3MXV-B 32-404 BS3F 3MXV-B 32-405 BS3F 3MXV-B 32-406 BS3F 3MXV-B 32-407 BS3F 3MXV-B 32-408/A BS3F 3MXV-B 32-410/A BS3F 3MXV-B 40-804 BS3F 3MXV-B 40-805/A BS3F 3MXV-B 40-806/A BS2F 3MXV-B 40-807/A BS2F 3MXV-B 40-808/A BS2F 3MXV-B 40-810/A BS3F 3MXV-B 50-1803/A BS3F 3MXV-B 50-1804/A BS3F 3MXV-B 50-1805/A BS3F 3MXV-B 50-1806/A BS3F 3MXV-B 50-1807/A BS3F 3MXV-B 50-1808/A BS3F 3MXV-B 50-1809/A BS3F 3MXV-B 50-1810/A
HP 1 x3 1 x3 1,5 x3 1,5 x3 2 x3 2 x3 1,5 x3 1,5 x3 2 x3 2 x3 3 x3 3 x3 2 x3 3 x3 3 x3 4 x3 4 x3 5 x3 3 x3 4 x3 5 x3 5,5 x3 7,5 x3 7,5 x3 10 x3 10 x3
* Maximum pumps flow at minimum setting pressure of 3
nd
Pres. switch 2 bar min max 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 6 9 2 3,5 3,1 4,6 4,1 5,6 5,2 6,7 6,2 7,7 5,5 8,5 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 8,5 10,5 1,5 2,7 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 6,5 8,5 7,5 9,5
Pres. switch 3 bar min max 1,9 3,4 2,9 4,4 3,9 5,4 4,9 6,4 5,9 7,4 5,5 8,5 1,7 3,2 2,8 4,3 3,8 5,3 4,9 6,4 5,9 7,4 5 8 1,9 3,4 2,9 4,4 3,9 5,4 4,9 6,4 5,9 7,4 8 10 1,2 2,4 1,9 3,4 2,9 4,4 3,9 5,4 4,9 6,4 5,9 7,4 6 8 7 9
Maximum capacity * l/min 216 197 180 168 157 203 385 353 330 304 285 373 643 658 640 632 604 565 1233 1218 1181 1096 1090 1041 1153 1123
Q
m 19 30 40 50 60 56 17 29 39 50 60 51 19 30 40 50 60 82 12 19 30 40 50 60 61 71
H
Vessel Membrane litre
Vessel
40 50 50 50 60 60 80 100 100 100 150 150 200 300 300 300 300 500 300 500 500 500 750 750 1000 1000
100 100 100 100 100 100 100 100 100 300 300 300 300 500 500 500 500 800 500 800 1000 800 1000 1000 2000 2000
litre
pressure switch.
Performance
BS.. PUMPS Nos N. POMPE 1
2
3
PUMPPOMPE TYPE TIPO
4
5
6 MXV-B 25-204 MXV-B 25-205 MXV-B 25-206 MXV-B 25-207 MXV-B 25-208 MXV-B 25-210 MXV-B 32-404 MXV-B 32-405 MXV-B 32-406
BS1V
BS2V
BS3V
BS4V
BS5V
BS6V
BS1V1F
BS1V2F
BS1V3F
BS1V4F
BS1V5F
BSM1V1F* BSM2V**
MXV-B 32-407 MXV-B 32-408/A MXV-B 32-410/A MXV-B 40-804 MXV-B 40-805/A MXV-B 40-806/A MXV-B 40-807/A MXV-B 40-808/A MXV-B 40-810/A MXV-B 50-1803/A MXV-B 50-1804/A MXV-B 50-1805/A MXV-B 50-1806/A MXV-B 50-1807/A MXV-B 50-1808/A MXV-B 50-1809/A MXV-B 50-1810/A
(*) SYSTEMS WITH: 1 variable speed pump three-phase motor 1 fixed speed pump single-phase motor Power supply to control panel 230 V single-phase
PP22 pompa ForPer each pump kW 0,75 0,75 1,1 1,1 1,5 1,5 1,1 1,1 1,5 1,5 2,2 2,2 1,5 2,2 2,2 3 3 3,7 2,2 3 3,7 4 5,5 5,5 7,5 7,5
HP 1 1 1,5 1,5 2 2 1,5 1,5 2 2 3 3 2 3 3 4 4 5 3 4 5 5,5 7,5 7,5 10 10
(**) Three-phase motor 230 V. Power supply to control panel: - 230 V three-phase - 230 V single-phase Frequency converter output is alwais 230 V three-phase.
543
51
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hv Hf
DN 2
DN1
h1 L1
m1 TYPE BS1. 1MXV-B 25-204 BS1. 1MXV-B 25-205 BS1. 1MXV-B 25-206 BS1. 1MXV-B 25-207 BS1. 1MXV-B 25-208 BS1. 1MXV-B 25-210 BS1. 1MXV-B 32-404 BS1. 1MXV-B 32-405 BS1. 1MXV-B 32-406 BS1. 1MXV-B 32-407 BS1. 1MXV-B 32-408/A BS1. 1MXV-B 32-410/A BS1. 1MXV-B 40-804 BS1. 1MXV-B 40-805/A BS1. 1MXV-B 40-806/A BS1. 1MXV-B 40-807/A BS1. 1MXV-B 40-808/A BS1. 1MXV-B 40-810/A BS1. 1MXV-B 50-1803/A BS1. 1MXV-B 50-1804/A BS1. 1MXV-B 50-1805/A BS1. 1MXV-B 50-1806/A BS1. 1MXV-B 50-1807/A BS1. 1MXV-B 50-1808/A BS1. 1MXV-B 50-1809/A BS1. 1MXV-B 50-1810/A
Connection Collettori
TYPE BSM1. BSM1. BSM1. BSM1. BSM1. BSM1. BSM1. BSM1. BSM1. BSM1.
1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM 1MXV-BM
25-204 25-205 25-206 25-207 25-208 25-210 32-404 32-405 32-406 32-407
mm
DN 1
DN 2
Hv
Hf
h1
L1
m1
G1
G1
1345
1065
120
625
410
G 1 1/4 G 1 1/4
1345
1065
120
625
410
G 1 1/2 G 1 1/2
1345
1065
125
625
410
135
625
410
BSM1. 1MXV-BM 40-804
1345 1065 G2
G2 1445 1445
544
weight Peso kg -
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hf Hv DN 2 DN 1 h2 h1 4.93.233.N
m1 L1
TYPE
Connection Collettori
TYPE BSM.. BSM.. BSM.. BSM.. BSM.. BSM.. BSM.. BSM.. BSM.. BSM..
2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM 2MXV-BM
B3f B3v
L2
DN 1 BS.. 2MXV-B 25-204 BS.. 2MXV-B 25-205 BS.. 2MXV-B 25-206 BS.. 2MXV-B 25-207 BS.. 2MXV-B 25-208 BS.. 2MXV-B 25-210 BS.. 2MXV-B 32-404 BS.. 2MXV-B 32-405 BS.. 2MXV-B 32-406 BS.. 2MXV-B 32-407 BS.. 2MXV-B 32-408/A BS.. 2MXV-B 32-410/A BS.. 2MXV-B 40-804 BS.. 2MXV-B 40-805/A BS.. 2MXV-B 40-806/A BS.. 2MXV-B 40-807/A BS.. 2MXV-B 40-808/A BS.. 2MXV-B 40-810/A BS.. 2MXV-B 50-1803/A BS.. 2MXV-B 50-1804/A BS.. 2MXV-B 50-1805/A BS.. 2MXV-B 50-1806/A BS.. 2MXV-B 50-1807/A BS.. 2MXV-B 50-1808/A BS.. 2MXV-B 50-1809/A BS.. 2MXV-B 50-1810/A
B
25-204 25-205 25-206 25-207 25-208 25-210 32-404 32-405 32-406 32-407
DN 2
G 1 1/2 G 1 1/2
G2
G2
B2
mm
Hf
Hv
h1
h2
L1
L2
m1
B
B2
B3f
B3v
875
1145
119
218
335
254
365
600
625
195
260
875
1145
119
225
360
295
365
600
625
195
260
BSM.. 2MXV-BM 40-804
G 2 1/2 G 2 1/2
G3
G3
875
965
1145
1445
124
225
245
225
400
495
305
405
365
550
600
700
625
950
195
160
260
220
weight Peso kg 105 107 109 111 118
108 111 115 118 121 116 119 121 143 145 208 228 238 240 262 264
51
545
BS. MXV-B
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hf Hv
DN 2 DN 1 h2 h1 4.93.233.N
m1 L1
TYPE BS.. 3MXV-B 25-204 BS.. 3MXV-B 25-205 BS.. 3MXV-B 25-206 BS.. 3MXV-B 25-207 BS.. 3MXV-B 25-208 BS.. 3MXV-B 25-210 BS.. 3MXV-B 32-404 BS.. 3MXV-B 32-405 BS.. 3MXV-B 32-406 BS.. 3MXV-B 32-407 BS.. 3MXV-B 32-408/A BS.. 3MXV-B 32-410/A BS.. 3MXV-B 40-804 BS.. 3MXV-B 40-805/A BS.. 3MXV-B 40-806/A BS.. 3MXV-B 40-807/A BS.. 3MXV-B 40-808/A BS.. 3MXV-B 40-810/A BS.. 3MXV-B 50-1803/A BS.. 3MXV-B 50-1804/A BS.. 3MXV-B 50-1805/A BS.. 3MXV-B 50-1806/A BS.. 3MXV-B 50-1807/A BS.. 3MXV-B 50-1808/A BS.. 3MXV-B 50-1809/A BS.. 3MXV-B 50-1810/A
B
B3f B3v
L2
Connection Collettori
B2
mm
DN 1
DN 2
Hf
Hv
h1
h2
L1
L2
m1
B
B2
B3f
B3v
G2
G2
1090
1160
134
233
340
254
406
950
1000
220
220
G 2 1/2 G 2 1/2
G3
100
G3
100
1090
1090
1190
1160
1160
1360
134
139
280
240
260
280
546
368
405
507
295
305
418
406
406
550
950
950
1200
1000
1000
1400
220
220
220
220
220
220
weight Peso kg 103 105 107 118 120
104 108 113 118 122 111 117 123 156 159 251 281 296 299 332 335
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 10 U.S. g.p.m. 30 40 50 10 Imp. g.p.m.
140
30 40 50
100 100
200
300 400 500
150 200
800
300 400 500 700
400
120
H
ft 100 300 80
1-3MXV
H m
200
60
40 100 20
0 2
m3 /h Q l/min
5 100
10 15 20 30 40 50 150 200 300 400 500 1000
100 150 200 2000 3000 72.949.C
Operation BS 1-6F
Electrical control boards: - with microprocessor for fixed speed pump units (see page 486). Motor starting is D.O.L. up to 5,5 kW and Y/∆ for power rating 7,5 up to 15 kW. - with frequency converter for variable speed pump units (see page 487).
Pressure boosting sets with 1 to 6 fixed speed pump. Sets with 4,5 and 6 pumps on request. Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the microprocessor alternates the starts.
The unit includes one pressure gauge and three adjustable differential pressure switches or pressure transducer (for sets with frequency converter).
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with frequency converter into the control panel) and from 1 to 5 fixed speed pumps Sets with 4,5 and 6 pumps on request. According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water quantity required at the set pressure. BS1-6V
Applications To supply water in civil and industrial buildings. As pressure boosting pump to increase water pressure when needed (follow local rules).
Pressure boosting sets with 1 to 6 variable speed pumps (with frequency converter into the control panel). Sets with 4,5 and 6 pumps on request. Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set pressure.
Motors 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with frequency converter. - Three-phase 230/400V ± 10% up to 3 kW; 400/690V ± 10% for 4 kW to 18,5 kW; - Single-phase 230 V ± 10%, (on request). Insulation class F. Protection IP 54. Constructed in accordance with: IEC 60034. Other voltages and frequencies on request.
Construction - Automatic pressure boosting plant consisting of 1 vertical multi-stage close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.
Vessels on request - Automatic pressure boosting plant consisting of 2 to 6 vertical multistage close coupled pumps complete with ball, non return valve on the suction side and ball valves on the delivery side. Suction and delivery manifolds are in AISI 304. Connections are located on the delivery manifold for the installation of 20 litres cylindrical vessels: - 2 vessels (for 2MXV 25-32-40), 1 vessel (for 2MXV 50-65-80). - 3 vessels (for 3MXV 25-32-40), 2 vessels (for 3MXV 50-65-80).
When installing the unit, connect in the delivery section to a diaphragm or galvanised tank. The recommended sized are shown in the following page.
Special features on request Pressure boosting sets with 4,5 and 6 pumps.
547
51
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0
U.S. g.p.m.
0
Imp. g.p.m.
20
30 20
40
50
30
60
40
50
140
0
U.S. g.p.m.
30
0
Imp. g.p.m.
40 30
50 40
60 50
70
80
60
90 70
100 80
110 90
140
1-3MXV 25
1-3MXV 32
400
120
400
120
100
100
12
12 300
H
10
80
300 80
ft
H m
8 7
7
6
6
4
100
20
100
20
0 0
m 3/h Q l/min
3 50
6 100
9 150
0 15 250
12 200
0
72.951.1C
0 U.S. g.p.m. 40 0 Imp. g.p.m.
60 40
80 60
100 80
120
140
100
160
120
180
140
1-3MXV 40
400
120
11
100
10
300
H
80
8
H m
ft
7 200
60
6 5
40
4 100
20
0 m 3/h 6 0 Q l/min
12 200
18 300
24 400
30 500
36 600
0 0
m 3/h Q l/min
6 100
12 200
18 300
24 400
27 72.951.2C
140
0
200
5
40
4
0
8
60
5
40
ft
H m
200
60
H
10
0 42 700 72.951.3C
548
0
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0
U.S. g.p.m.
0
Imp. g.p.m.
140
100
200 100
150
300 200
250
0
U.S. g.p.m.
0
Imp. g.p.m.
200
300 200
400
500
300
400
600 500
140
1-3MXV 50-16
400
120
1-3MXV 65-32
400
120
ft
8
100
ft 100
7
7
300
300 6
80
6
80
5 H
5
H
200
m
4
3
3
40
40 2
100 20
0
200
4
m
100
20
0 0
Q
m 3/h 15 300 l/min
30
45 600
60
75 1200
900
0
0
72.953.1C
0 U.S. g.p.m. 200 0 Imp. g.p.m.
300
200
400 300
500 400
600
700
500
0 m 3/h Q l/min 500 0
50
100 1000
1500
2000
0 150 2500 72.953.2C
800
600
140
1-3MXV 80-48 120
400
100 7
300
6
80
H ft
H 5
m
200
60 4
3
40
100
2
20
0
51 0 m3/h 40 Q 0 l/min 500
60 1000
80 100 1500
120 2000
140 160 2500
180 3000
0
72.953.3C
549
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F Mains: 400V 3~ Motor: 400V 3~
BSM1F Mains: 230V 1~ Motor: 230V 1~
BS1F 1MXV 25-204/C
BSM1F 1MXV 25-204M/C
BS1F 1MXV 25-205/C BS1F 1MXV 25-206/C
BSM1F 1MXV 25-205M/C BSM1F 1MXV 25-206M/C
BS1F 1MXV 25-207/C
BSM1F 1MXV 25-207M/C
BS1F 1MXV 25-208/C BS1F 1MXV 25-210/C
BSM1F 1MXV 25-208M/C
BS1F 1MXV 25-212/C BS1F 1MXV 32-404/C BS1F 1MXV 32-405/C
BSM1F 1MXV 32-404M/C BSM1F 1MXV 32-405M/C
BS1F 1MXV 32-406/C
BSM1F 1MXV 32-406M/C
BS1F 1MXV 32-407/C BS1F 1MXV 32-408/C
BSM1F 1MXV 32-407M/C
BS1F 1MXV 32-410/C BS1F 1MXV 32-412/C BS1F 1MXV 40-804/C BS1F 1MXV 40-805/C
BSM1F 1MXV 40-804M/C
BS1F 1MXV 40-806/C BS1F 1MXV 40-807/C BS1F 1MXV 40-808/C BS1F 1MXV 40-810/C BS1F 1MXV 40-811/C BS1F 1MXV 50-1603/C BS1F 1MXV 50-1604/C BS1F 1MXV 50-1605/C BS1F 1MXV 50-1606/C BS1F 1MXV 50-1607/C BS1F 1MXV 50-1608/C BS1F 1MXV 65-3202/C BS1F 1MXV 65-3203/C BS1F 1MXV 65-3204/C BS1F 1MXV 65-3205/D BS1F 1MXV 65-3206/D BS1F 1MXV 65-3207/D BS1F 1MXV 80-4802/C BS1F 1MXV 80-4803/C BS1F 1MXV 80-4804/D BS1F 1MXV 80-4805/D BS1F 1MXV 80-4806/D BS1F 1MXV 80-4807/D
BS2F Mains: 400V 3~ Motor: 400V 3~ BS2F 2MXV 25-204/C BS2F 2MXV 25-205/C BS2F 2MXV 25-206/C
Alimentazione 230V 1~ Motore 230V 1~
HP 1 1 1,5 1,5 2 2 3 1,5 1,5 2 2 3 3 4 2 3 3 4 4 5,5 5,5 4 5,5 7,5 7,5 10 10 5,5 7,5 10 15 15 20 7,5 10 15 20 20 25
Motor kW
BSM2F 2MXV 25-204M/C BSM2F 2MXV 25-205M/C BSM2F 2MXV 25-206M/C BSM2F 2MXV 25-207M/C
BS2F 2MXV 25-208/C BS2F 2MXV 25-210/C
BSM2F 2MXV 25-208M/C
BS2F 2MXV 25-212/C BS2F 2MXV 32-404/C BS2F 2MXV 32-405/C
BSM2F 2MXV 32-404M/C BSM2F 2MXV 32-405M/C
BS2F 2MXV 32-406/C
BSM2F 2MXV 32-406M/C
BS2F 2MXV 32-407/C BS2F 2MXV 32-408/C
BSM2F 2MXV 32-407M/C
BS2F 2MXV 32-410/C BS2F 2MXV 32-412/C BSM2F 2MXV 40-804M/C
BS2F 2MXV 40-806/C BS2F 2MXV 40-807/C BS2F 2MXV 40-808/C BS2F 2MXV 40-810/C BS2F 2MXV 40-811/C BS2F 2MXV 50-1603/C BS2F 2MXV 50-1604/C BS2F 2MXV 50-1605/C BS2F 2MXV 50-1606/C BS2F 2MXV 50-1607/C BS2F 2MXV 50-1608/C BS2F 2MXV 65-3202/C BS2F 2MXV 65-3203/C BS2F 2MXV 65-3204/C BS2F 2MXV 65-3205/D BS2F 2MXV 65-3206/D BS2F 2MXV 65-3207/D BS2F 2MXV 80-4802/C BS2F 2MXV 80-4803/C BS2F 2MXV 80-4804/D BS2F 2MXV 80-4805/D BS2F 2MXV 80-4806/D BS2F 2MXV 80-4807/D
* Maximum pumps flow at minimum setting pressure of 2
kW 0,75 0,75 1,1 1,1 1,5 1,5 2,2 1,1 1,1 1,5 1,5 2,2 2,2 3 1,5 2,2 2,2 3 3 4 4 3 4 5,5 5,5 7,5 7,5 4 5,5 7,5 11 11 15 5,5 7,5 11 15 15 18,5
min 2,3 3,5 4,5 5,5 6,5 7,5 8,5 2,3 3,4 4,5 5,5 6,5 7,5 8,5 2,5 3,5 4,5 5,5 6,5 7,5 8,5 3 4,5 6 7,5 9 10,5 2,2 3,8 5 6,5 8 9,5 2,2 3,8 5 6,5 8 9,5
max 3,8 5 6 7 8 9 10 3,8 4,9 6 7 8 9 10 4 5 6 7 8 9 10 4,5 6 7,5 9 10,5 12 3,1 4,8 6,5 8 9,5 11 3,2 5 6,5 8 9,5 11
Maximum capacity * Q
l/min
66 56 51 48 45 51 55 114 103 93 88 83 94 100 214 211 198 194 184 199 195 367 341 313 297 286 272 670 587 602 572 555 538 869 778 820 782 756 741
H
Vessel Membrane litre
m
23 36 46 56 66 76 87 23 35 46 56 66 76 87 25 36 46 56 66 76 87 31 46 61 76 92 107 22 39 51 66 82 97 22 39 51 66 82 97
Vessel litre
40 50 50 60 100 100 200 100 100 100 100 200 300 300 200 300 300 500 500 1000 1000 500 750 1000 1000 1500 1500 1000 1500 1500 2000 3000 4000 1500 2000 3000 4000 5000 5000
100 100 100 100 100 200 200 100 200 200 200 300 500 500 300 500 500 800 800 1000 1000 800 1000 1500 1500 2000 2000 2000 3000 3000 4000 4000 5000 3000 3000 4000 5000 -
* Maximum pumps flow at minimum setting pressure switch.
BSM2F
BS2F 2MXV 25-207/C
BS2F 2MXV 40-804/C BS2F 2MXV 40-805/C
Pres. switch 1 bar bar
Motor
nd
0,75 x2 0,75 x2 1,1 x2 1,1 x2 1,5 x2 1,5 x2 2,2 x2 1,1 x2 1,1 x2 1,5 x2 1,5 x2 2,2 x2 2,2 x2 3 x2 1,5 x2 2,2 x2 2,2 x2 3 x2 3 x2 4 x2 4 x2 3 x2 4 x2 5,5 x2 5,5 x2 7,5 x2 7,5 x2 4 x2 5,5 x2 7,5 x2 11 x2 11 x2 15 x2 5,5 x2 7,5 x2 11 x2 15 x2 15 x2 18,5 x2
HP 1 x2 1 x2 1,5 x2 1,5 x2 2 x2 2 x2 3 x2 1,5 x2 1,5 x2 2 x2 2 x2 3 x2 3 x2 4 x2 2 x2 3 x2 3 x2 4 x2 4 x2 5,5 x2 5,5 x2 4 x2 5,5 x2 7,5 x2 7,5 x2 10 x2 10 x2 5,5 x2 7,5 x2 10 x2 15 x2 15 x2 20 x2 7,5 x2 10 x2 15 x2 20 x2 20 x2 25 x2
pressure switch.
Pres. switch 1 bar min max 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 2,3 3,8 3,4 4,9 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 3 4,5 4,5 6 6 7,5 7,5 9 9 10,5 10,5 12 2,1 3,1 3,8 4,8 5 6,5 6,5 8 8 9,5 9,5 11 2,2 3,2 3,8 5 5 6,5 6,5 8 8 9,5 9,5 11
550
Pres. switch 2 bar min max 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 7 8,5 8 9,5 2 3,5 3,1 4,6 4,2 5,7 5,2 6,7 6,2 7,7 7 8,5 8 9,5 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 7 8,5 8 9,5 2,5 4 4 5,5 5,5 7 7 8,5 8,5 10 10 11,5 1,8 2,8 3,3 4,3 4,5 6 6 7,5 7,5 9 9 10,5 1,9 2,9 3,3 4,5 4,5 6 6 7,5 7,5 9 9 10,5
Maximum capacity * Q
l/min
135 122 111 104 97 112 118 244 222 202 190 178 203 213 435 435 414 407 387 416 408 785 743 686 650 623 592 1451 1340 1325 1255 1212 1165 1877 1755 1788 1696 1628 1586
H
m
22 33 43 53 63 71 82 20 32 43 53 63 71 82 22 33 43 53 63 71 82 25 41 56 71 87 102 18 34 46 61 76 92 19 34 46 61 76 92
Vessel Membrane litre
Vessel
40 50 50 60 100 100 200 100 100 100 100 200 300 300 200 300 300 500 500 1000 1000 500 750 1000 1000 1500 1500 1000 1500 1500 2000 3000 4000 1500 2000 3000 4000 5000 5000
100 100 100 100 100 200 200 100 200 200 200 300 500 500 300 500 500 800 800 1000 1000 800 1000 1500 1500 2000 2000 2000 3000 3000 4000 4000 5000 3000 3000 4000 5000 -
litre
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS3F Mains: 400V 3~ Motor: 400V 3~
Pres. switch 1 bar min max 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 2,3 3,8 3,4 4,9 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 2,5 4 3,5 5 4,5 6 5,5 7 6,5 8 7,5 9 8,5 10 3 4,5 4,5 6 6 7,5 7,5 9 9 10,5 10,5 12 2,1 3,1 3,8 4,8 5 6,5 6,5 8 8 9,5 9,5 11 2,2 3,2 3,8 5 5 6,5 6,5 8 8 9,5 9,5 11
Motor kW 0,75 x3 0,75 x3 1,1 x3 1,1 x3 1,5 x3 1,5 x3 2,2 x3 1,1 x3 1,1 x3 1,5 x3 1,5 x3 2,2 x3 2,2 x3 3 x3 1,5 x3 2,2 x3 2,2 x3 3 x3 3 x3 4 x3 4 x3 3 x3 4 x3 5,5 x3 5,5 x3 7,5 x3 7,5 x3 4 x3 5,5 x3 7,5 x3 11 x3 11 x3 15 x3 5,5 x3 7,5 x3 11 x3 15 x3 15 x3 18,5 x3
BS3F 3MXV 25-204/C BS3F 3MXV 25-205/C BS3F 3MXV 25-206/C BS3F 3MXV 25-207/C BS3F 3MXV 25-208/C BS3F 3MXV 25-210/C BS3F 3MXV 25-212/C BS3F 3MXV 32-404/C BS3F 3MXV 32-405/C BS3F 3MXV 32-406/C BS3F 3MXV 32-407/C BS3F 3MXV 32-408/C BS3F 3MXV 32-410/C BS3F 3MXV 32-412/C BS3F 3MXV 40-804/C BS3F 3MXV 40-805/C BS3F 3MXV 40-806/C BS3F 3MXV 40-807/C BS3F 3MXV 40-808/C BS3F 3MXV 40-810/C BS3F 3MXV 40-811/C BS3F 3MXV 50-1603/C BS3F 3MXV 50-1604/C BS3F 3MXV 50-1605/C BS3F 3MXV 50-1606/C BS3F 3MXV 50-1607/C BS3F 3MXV 50-1608/C BS3F 3MXV 65-3202/C BS3F 3MXV 65-3203/C BS3F 3MXV 65-3204/C BS3F 3MXV 65-3205/D BS3F 3MXV 65-3206/D BS3F 3MXV 65-3207/D BS3F 3MXV 80-4802/C BS3F 3MXV 80-4803/C BS3F 3MXV 80-4804/D BS3F 3MXV 80-4805/D BS3F 3MXV 80-4806/D BS3F 3MXV 80-4807/D
HP 1 x3 1 x3 1,5 x3 1,5 x3 2 x3 2 x3 3 x3 1,5 x3 1,5 x3 2 x3 2 x3 3 x3 3 x3 4 x3 2 x3 3 x3 3 x3 4 x3 4 x3 5,5 x3 5,5 x3 4 x3 5,5 x3 7,5 x3 7,5 x3 10 x3 10 x3 5,5 x3 7,5 x3 10 x3 15 x3 15 x3 20 x3 7,5 x3 10 x3 15 x3 20 x3 20 x3 25 x3
Pres. switch 3 bar min max 1,9 3,4 2,9 4,4 3,9 5,4 4,9 6,4 5,9 7,4 6,5 8 7,5 8 1,7 3,2 2,8 4,3 3,9 5,4 4,9 6,4 5,9 7,4 6,5 8 7,5 9 1,9 3,4 2,9 4,4 3,9 5,4 4,9 6,4 5,9 7,4 6,5 8 7,5 9 2 3,5 3,5 5 5 6,5 6,5 8 8 9,5 9,5 11 1,5 2,5 2,8 3,8 4 5,5 5,5 7 7 8,5 8,5 10 1,6 2,6 2,8 4 4 5,5 5,5 7 7 8,5 8,5 10
PUMPS Nos N. POMPE 2
3
4
PUMP TYPE TIPO POMPE 5
6 MXV 25-204/C MXV 25-205/C MXV 25-206/C MXV 25-207/C MXV 25-208/C MXV 25-210/C MXV 25-212/C MXV 32-404/C MXV 32-405/C MXV 32-406/C MXV 32-407/C MXV 32-408/C MXV 32-410/C MXV 32-412/C MXV 40-804/C MXV 40-805/C MXV 40-806/C
BS1V
Maximum capacity * l/min 216 197 180 168 157 181 187 385 353 323 304 285 325 335 643 658 640 632 604 642 633 1201 1173 1101 1045 1003 952 2208 2159 2116 2017 1945 1865 2969 2864 2857 2713 2598 2520
Q
m 19 30 40 50 60 66 76 17 29 40 50 60 66 76 19 30 40 50 60 66 76 20 36 51 66 82 97 15 29 41 56 71 87 16 29 41 56 71 87
H
* Maximum pumps flow at minimum setting pressure of 3
BS..
1
Pres. switch 2 bar min max 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 7 8,5 9,5 8 2 3,5 3,1 4,6 4,2 5,7 6,7 5,2 6,2 7,7 7 8,5 9,5 8 2,2 3,7 3,2 4,7 4,2 5,7 5,2 6,7 6,2 7,7 7 8,5 8 9,5 2,5 4 4 5,5 5,5 7 7 8,5 8,5 10 10 11,5 1,8 2,8 3,3 4,3 4,5 6 6 7,5 7,5 9 9 10,5 1,9 2,9 3,3 4,5 4,5 6 6 7,5 7,5 9 9 10,5
BS2V
BS3V
BS4V
BS5V
BS6V
BS1V1F
BS1V2F
BS1V3F
BS1V4F
BS1V5F
BSM1V1F* BSM2V**
MXV 40-807/C MXV 40-808/C MXV 40-810/C MXV 40-811/C MXV 50-1603/C MXV 50-1604/C MXV 50-1605/C MXV 50-1606/C MXV 50-1607/C MXV 50-1608/C MXV 65-3202/C MXV 65-3203/C MXV 65-3204/C MXV 65-3205/D MXV 65-3206/D MXV 65-3207/D MXV 80-4802/C MXV 80-4803/C MXV 80-4804/D MXV 80-4805/D MXV 80-4806/D MXV 80-4807/D
551
nd
Vessel Membrane litre
Vessel
40 50 50 60 100 100 200 100 100 100 100 200 300 300 200 300 300 500 500 1000 1000 500 750 1000 1000 1500 1500 1000 1500 1500 2000 3000 4000 1500 2000 3000 4000 5000 5000
100 100 100 100 100 200 200 100 200 200 200 300 500 500 300 500 500 800 800 1000 1000 800 1000 1500 1500 2000 2000 2000 3000 3000 4000 4000 5000 3000 3000 4000 5000 -
litre
pressure switch.
PP2 2 pompa ForPer each pump kW 0,75 0,75 1,1 1,1 1,5 1,5 2,2 1,1 1,1 1,5 1,5 2,2 2,2 3 1,5 2,2 2,2 3 3 4 4 3 4 5,5 5,5 7,5 7,5 4 5,5 7,5 11 11 15 5,5 7,5 11 15 15 18,5
HP 1 1 1,5 1,5 2 2 3 1,5 1,5 2 2 3 3 4 2 3 3 4 4 5,5 5,5 4 5,5 7,5 7,5 10 10 5,5 7,5 10 15 15 20 7,5 10 15 20 20 25
(*) SYSTEMS WITH: 1 variable speed pump three-phase motor 1 fixed speed pump single-phase motor Power supply to control panel 230 V single-phase
(**) Three-phase motor 230 V. Power supply to control panel: - 230 V three-phase - 230 V single-phase Frequency converter output is alwais 230 V three-phase.
51
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hv Hf
DN 2
DN1
h1
L1
m1
TYPE
Connection Collettori
TYPE
BS1. 1MXV 25-204 BS1. 1MXV 25-205
BSM1. 1MXV 25-204M BSM1. 1MXV 25-205M
BS1. 1MXV 25-206 BS1. 1MXV 25-207 BS1. 1MXV 25-208 BS1. 1MXV 25-210 BS1. 1MXV 25-212
BSM1. 1MXV 25-206M BSM1. 1MXV 25-207M BSM1. 1MXV 25-208M
BS1. 1MXV 32-404 BS1. 1MXV 32-405 BS1. 1MXV 32-406 BS1. 1MXV 32-407
BSM1. 1MXV 32-404M BSM1. 1MXV 32-405M BSM1. 1MXV 32-406M BSM1. 1MXV 32-407M
BS1. 1MXV 32-408 BS1. 1MXV 32-410 BS1. 1MXV 32-412 BS1. 1MXV 40-804 BS1. 1MXV 40-805 BS1. 1MXV 40-806 BS1. 1MXV 40-807 BS1. 1MXV 40-808 BS1. 1MXV 40-810
mm
DN 1
DN 2
Hv
Hf
h1
L1
m1
G1
G1
1345
1065
120
625
410
G 1 1/4 G 1 1/4
1345
1065
120
625
410
G 1 1/2 G 1 1/2
1345
1065
125
625
410
BSM1. 1MXV 40-804M
BS1. 1MXV 40-811
Hv Hf
DN1
DN 2
h1
L1
m1
TYPE
Connection Collettori DN 1
BS.. 1MXV 50-1603 BS.. 1MXV 50-1604 BS.. 1MXV 50-1605 BS.. 1MXV 50-1606 BS.. 1MXV 50-1607 BS.. 1MXV 50-1608 BS.. 1MXV 65-3202 BS.. 1MXV 65-3203 BS.. 1MXV 65-3204 BS.. 1MXV 65-3205 BS.. 1MXV 65-3206 BS.. 1MXV 65-3207 BS.. 1MXV 80-4802 BS.. 1MXV 80-4803 BS.. 1MXV 80-4804 BS.. 1MXV 80-4805 BS.. 1MXV 80-4806 BS.. 1MXV 80-4807
DN 2
mm Hv
Hf
h1
L1
m1
225
950
550
240
950
550
240
950
550
1485 1155 G2
G2 1585 1585 1485
1155
1585 G 2 1/2 G 2 1/2 1685 1585 G3
G3
1685 1785
552
1585 1155
1585
weight Peso kg
weight Peso kg -
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hf Hv DN 2 DN 1 h2 h1 4.93.233.N
m1 L1
TYPE
B B3f B3v
L2
B2
Connection Collettori
TYPE
DN 1 BS.. 2MXV 25-204
BS.. 2MXV 25-204M
BS.. 2MXV 25-205
BS.. 2MXV 25-205M
BS.. 2MXV 25-206
BS.. 2MXV 25-206M
BS.. 2MXV 25-207
BS.. 2MXV 25-207M
BS.. 2MXV 25-208
BS.. 2MXV 25-208M
BS.. 2MXV 25-210
BS.. 2MXV 25-210M
BS.. 2MXV 25-212
BS.. 2MXV 25-212M
BS.. 2MXV 32-404
BS.. 2MXV 32-404M
BS.. 2MXV 32-405
BS.. 2MXV 32-405M
BS.. 2MXV 32-406
BS.. 2MXV 32-406M
BS.. 2MXV 32-407
BS.. 2MXV 32-407M
DN 2
G 1 1/2 G 1 1/2
G2
G2
mm Hf
Hv
h1
h2
L1
L2
m1
B
B2
B3f
B3v
875
1145
119
218
335
254
365
600
625
195
260
875
1145
119
225
360
295
365
600
625
195
260
BS.. 2MXV 32-408
weight Peso kg 110 112 114 116 126
113 115 125 127 137
BS.. 2MXV 32-410 BS.. 2MXV 32-412 BS.. 2MXV 40-804
BS.. 2MXV 40-804M
BS.. 2MXV 40-805 BS.. 2MXV 40-806
G 2 1/2 G 2 1/2
BS.. 2MXV 40-807
875
1145
124
245
400
305
365
600
625
BS.. 2MXV 40-808
195
260
126 136 138 164 166
BS.. 2MXV 40-810 BS.. 2MXV 40-811
Hf Hv
DN 1
DN 2
h1 B
m1 L1
TYPE
L2
B4 B2
Connection Collettori
mm
DN 1
DN 2
Hf
Hv
h1
L1
L2
m1
B
B2
B3f
G3
G3
965
1445
225
455
355
550
700
950
160
B3f B3v
B3v
B4
BS.. 2MXV 50-1603 BS.. 2MXV 50-1604 BS.. 2MXV 50-1605 BS.. 2MXV 50-1606
170
225
weight Peso kg 282 298 336 340
BS.. 2MXV 50-1607 BS.. 2MXV 50-1608 BS.. 2MXV 65-3202
965
BS.. 2MXV 65-3203 BS.. 2MXV 65-3204 BS.. 2MXV 65-3205
100
100
240 1445
BS.. 2MXV 65-3206
160
1445 560
425
550
750
170
950
200 170
1545
358 396 420 480
220
BS.. 2MXV 65-3207 BS.. 2MXV 80-4802
965
BS.. 2MXV 80-4803 BS.. 2MXV 80-4804 BS.. 2MXV 80-4805 BS.. 2MXV 80-4806
125
125
160
1445
1445
240
640
500
1545
BS.. 2MXV 80-4807
550
750
950
170
170 220 270
553
200
408 432 490 520
51
BS. MXV
Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and weights
Hf Hv
DN 2 DN 1 h2 h1 4.93.233.N
m1 L1
B
B3f B3v
L2
B2
Connection Collettori
TYPE
mm
DN 1
DN 2
Hf
Hv
G2
G2
1090
1160
h1
h2
L1
L2
m1
B
B2
B3f
B3v
134
233
340
254
406
950
1000
220
220
BS.. 3MXV 25-204 BS.. 3MXV 25-205 BS.. 3MXV 25-206 BS.. 3MXV 25-207 BS.. 3MXV 25-208
weight Peso kg 110 112 114 116 126
BS.. 3MXV 25-210 BS.. 3MXV 25-212 BS.. 3MXV 32-404 BS.. 3MXV 32-405 BS.. 3MXV 32-406
G 2 1/2 G 2 1/2
BS.. 3MXV 32-407
1090
1160
134
240
368
295
406
950
1000
220
220
BS.. 3MXV 32-408
113 115 125 127 137
BS.. 3MXV 32-410 BS.. 3MXV 32-412 BS.. 3MXV 40-804 BS.. 3MXV 40-805 BS.. 3MXV 40-806
G3
BS.. 3MXV 40-807
G3
1090
1160
139
260
405
305
406
950
1000
220
220
BS.. 3MXV 40-808 BS.. 3MXV 40-810 BS.. 3MXV 40-811
Hf Hv
DN 1
DN 2
h1 B
m1 L1
B2
Connection Collettori DN 1
DN 2
Hf
BS.. 3MXV 50-1603
BS.. 3MXV 50-1606
100
100
L1
L2
m1
B
B2
B3f
BS.. 3MXV 65-3202
1160
BS.. 3MXV 65-3203
275
BS.. 3MXV 65-3206
B4
470
365
550
1200
1400
200 220
weight Peso kg 282 298 336 340
220 1440
125
200
170 220
290 1540
B3v 170
1540 125
B3f B3v
200
1160 1540
BS.. 3MXV 50-1608
BS.. 3MXV 65-3205
h1
1540
BS.. 3MXV 50-1607
BS.. 3MXV 65-3204
Hv
mm
1440
BS.. 3MXV 50-1604 BS.. 3MXV 50-1605
B4
L2
672
487
550
1200
1400
200 220
*
358 396 420 480
*
BS.. 3MXV 65-3207 BS.. 3MXV 80-4802
1160
BS.. 3MXV 80-4803 BS.. 3MXV 80-4804 BS.. 3MXV 80-4805 BS.. 3MXV 80-4806
150
200
1540
150
290 1540
655
*
550
1200
1400
200 220
BS.. 3MXV 80-4807
* Cabinet version
515
554
220
*
408 432 490 520
126 136 138 164 166
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 50
100
50
U.S. g.p.m.
100
300
Imp. g.p.m.
500
300
1000
500
2000
1000
2000
120
100 90
30
80
H
m
H m
1-3NM-NMD 20
60
50
40
10
30
90 80 70 20 10
m /h 20 Q l/min 200 3
30 500
40 50 1000
100 2000
200 3000
400 5000
600 10000 72.961.C
Operation BS 1-6F
Electrical control boards: - with microprocessor for fixed speed pump units (see page 486). Motor starting is D.O.L. up to 5,5 kW and Y/∆ for power rating 7,5 up to 55 kW. - with frequency converter for variable speed pump units (see page 487).
Pressure boosting sets with 1 to 6 fixed speed pump. Sets with 4,5 and 6 pumps on request. Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the microprocessor alternates the starts.
The unit includes one pressure gauge and three adjustable differential pressure switches or pressure transducer (for sets with frequency converter).
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with frequency converter into the control panel) and from 1 to 5 fixed speed pumps Sets with 4,5 and 6 pumps on request. According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water quantity required at the set pressure. BS1-6V
Applications To supply water in civil and industrial buildings. As pressure boosting pump to increase water pressure when needed (follow local rules).
Pressure boosting sets with 1 to 6 variable speed pumps (with frequency converter into the control panel). Sets with 4,5 and 6 pumps on request. Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set pressure.
Motors 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with frequency converter. - Three-phase 230/400V ± 10% up to 3 kW; 400/690V ± 10% for 4 kW to 55 kW; Insulation class F. Protection IP 54. Constructed in accordance with: IEC 60034. Other voltages and frequencies on request.
Construction - Automatic pressure boosting plant consisting of 1 centrifugal pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.
Vessels on request When installing the unit, connect in the delivery section to a diaphragm or galvanised tank. The recommended sized are shown in the following page.
- Automatic pressure boosting plant consisting of 2 to 6 centrifugal pumps complete with ball, non return valve on the suction side and ball valves on the delivery side. Suction and delivery manifolds are in steel. Connections are located on the delivery manifold for the installation of 20 litres cylindrical vessels: - 2 vessels (for 2NM). - 3 vessels (for 3NM).
Special features on request Pressure boosting sets with 4,5 and 6 pumps.
555
51
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 32
100
0 Imp g.p.m. 50
150 100
0 U.S. g.p.m.
200 150
37
1-3NM 32/16BE
30
100
200 150 120
1-3NM 32/16AE
35
ft 90
25
0 Imp g.p.m. 50
150
100 H
H m
100
H
ft 110
H m
80 100
30 70 20 10 8 m 6 4 2 0 0 m 3/h10 0 Q l/min 200
28 10 8 m 6 H S4 P 2 N 0
30 ft 10 20
400
30
600
40
50 800
0
30 ft 10 0 m 3/h10 0 Q l/min 200
20
400
30
600
40
72.958.1C
0 U.S. g.p.m.
100
0 Imp g.p.m. 50
150 100
72.958.2C
200
0 U.S. g.p.m.
150
59
150 45
100
0 Imp g.p.m. 50
150 100
1-3NM 32/20C/A
H m
200 150 190
1-3NM 32/20A/A
57 H
140 ft
55 m
180
130
53
ft
H
40
0
50 800
H
170 51
120 35 10 8 m 6 H S4 P 2 N 0
30 ft 10 0 m 3/h10 0 Q l/min 200
20
400
30
600
40
0
50 800
49 6
m
ft 10
4
H S P2 N
0
0 m 3/h10 0 Q l/min 200
20
400
30
600
40
72.958.3C
0 U.S. g.p.m. 50 80
0 Imp g.p.m.
100
50
0 U.S. g.p.m. 50 150
1-3NMD 32/210D/A
70 H m 60
72.958.4C
150 100
0
50 800
0 Imp g.p.m.
100
50
100
H
ft
150 300
90 H m 80
240
150
1-3NMD 32/210C/A
H
ft 260
200 70
50
220
160 60
40
180 120
8 m 6 H 4 S P 2 N 0
20 ft 10 0 Q m 3/h 10 0 l/min 200
20 300
400
30 500
40 600 700
0
50 8 m 6 H 4 S P 2 N 0
72.958.5C
20 ft 10 0 Q m 3/h 10 0 l/min 200
20 300
400
30 500
40 600 700
0
72.958.6C
556
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 50 0 Imp g.p.m. 110
100
150
50
0 U.S. g.p.m. 50
100
150
1-3NMD 32/210B/A
H m 100
0 Imp g.p.m.
360
50
150 100
120
340
150
400
1-3NMD 32/210A/B
380
H m 110
H
320 ft 300
90
100
H
360 ft 340
100 320
280 80
260
74 8 m 6 H4 S P2 N 0
300
90 8
m 6
20 ft 10 0 Q m 3/h 10 0 l/min 200
20 300
30 500
400
0
40 600 700
20 ft 10
H4 S P2 N
0
0 Q m 3/h 10 0 l/min 200
20 300
30 500
400
72.958.7C
0 U.S. g.p.m. 70
0 Imp g.p.m.
100
150
100
200 150
250 200
72.958.8C
300
0 U.S. g.p.m.
250
0 Imp g.p.m.
1-3NMD 40/180D/A
200 H
160 ft 140
100
200 150
250 200
300 250
1-3NMD 40/180C/A
H
160
100
30
140 40
80
120 10 8 m 6 H4 S P2 N0 0 m3/h 0 Q l/min 200
30 ft 10 0 m3/h 0 Q l/min 200
20 30 40 400 600
50 800
60 1000
0 70 1200
30 ft 10 20 30 40 400 600
50 800
60 1000
90
0 Imp g.p.m.
100 100
150
200 150
250
300
200
0 U.S. g.p.m.
250
1-3NMD 40/180B/A 80 H m
0 70 1200 72.958.10C
72.958.9C
0 U.S. g.p.m.
220 200 ft 180
50
120
20 10 8 m 6 H S4 P2 N 0
150
70 H m 60
180
40
100
240
220
60 H m 50
0
40 600 700
100
0 Imp g.p.m.
100 100
150
200 150
250 200
300 250 320
280
1-3NMD 40/180A/B
260
90
300
H
H
280
70
240 ft 220
80
60
200
260 ft 240
70
m
H
220
180 50 6 m
ft 10
4
H S 2 P N
0
200
60 6
0 m3/h 0 Q l/min 200
20 30 40 400 600
50 800
60 1000
0 70 1200
m
ft 10
4
H S 2 P N
0
72.958.11C
0 m3/h 0 Q l/min 200
20 30 40 400 600
50 800
60 1000
0 70 1200 72.958.12C
557
51
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 100 30
200
0 Imp g.p.m. 100
300 200
400
0 U.S. g.p.m. 100
300
0 Imp g.p.m. 100 38
100
1-3NM 40/16B/B
H m
200
300 200
400 300
1-3NM 40/16A/B
90
120
H m
80
H
35
70
ft
H
110
ft
25
40 30
22 6
20
4
ft 10
m
H S 2 P N
0 0 m 3/h 20 0 Q l/min 500
40
60 1000
80
1500
100
30 6
m
ft 10
4
H S 2 P N
0 100
0 0 m 3/h 20 0 Q l/min 500
40
60 1000
80
1500
72.959.1C
0 U.S. g.p.m.
200
0 Imp g.p.m.100
300
400
200
72.959.2C
0 U.S. g.p.m.
500
300
400
54
200
60
1-3NM 40/20A/A
0 Imp g.p.m. 100
300 200
400 300
ft
H
ft
H m
170
150
45
160
140
150 40
140 40 6
130
6
m
m
ft 10
4
H S2 P N
0
170
50
H
50
200
1-3NM 40/20B/A
190
H m
0 100
0 m 3/h20 40 0 Ql/min 500
60 1000
80
100 1500
120 2000
ft 10
4
H S P2 N
0 0 m 3/h 20 0 Q l/min 500
0
40
60 1000
80
1500
72.959.3C
72.959.4C
0 U.S. g.p.m. 100
200
0 Imp g.p.m. 100 73
300 200
400
0 U.S. g.p.m.100
300
200
0 Imp g.p.m. 100 95 H m
H
90
ft 220
H m
300 200
400 300 310
1-3NM 40/25A/C
230
1-3NM 40/25B/C 70
0 100
300 H
290 ft
65
280
85 210
270 200
60 7
20 ft 10
m
5
H S 3 P N
1
0 m3/h 20 0 Q l/min
500
40
60 1000
80
1500
80
260
6 m
ft 10
4
H S 2 P N
0
100
72.959.5C
0 m 3/h 20 0 Q l/min
500
40
60 1000
80
1500
0 100
72.959.6C
558
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m.200
400
0 Imp g.p.m. 200 34
600
800
400
0 U.S. g.p.m.
600
40
110
400
0 Imp g.p.m. 200
600 400
800
1000
600
1-3NM 50/16B/B
800 130
1-3NM 50/16A/B 100
30
120
H
H m
35 H m
90 ft
25
H
110 ft
80
100
30 70
90
20 60
25 6
6
m
0
m
ft 10
4
H S 2 P N
0 m3/h 0 Q l/min
50 1000
100
150
2000
3000
ft 10
4
H S 2 P N
0 200
0
0 m 3/h 0 Q l/min
50 1000
100
2000
150
3000
72.959.7C
0 U.S. g.p.m. 200
400
0 Imp g.p.m. 200 58
600
72.959.8C
0 U.S. g.p.m. 200
800
400
600
190
50
180
H m
H
45
1-3NM 50/20A/C
55 H
m
0 230
200
400
0 Imp g.p.m. 200
600
800
400
600 160
1-3NM 50/20B/C
150 H
170 ft
50
160
140 ft 40
130
150
45
120
42 8 m 6 H4 S P2 N 0 0 m 3/h 0 Q l/min
140
35 8
m 6
20 ft 10 50 1000
100
150
2000
3000
20 ft 10
H 4 S P 2 N
0 200
0
0 m 3/h 0 Q l/min
50 1000
100
150
2000
72.959.9C
72.959.10C
0 U.S. g.p.m.200 0 Imp g.p.m.
200
400
600
0 U.S. g.p.m.200
400
600
1-3NM 50/25C/C
60 H
0 Imp g.p.m. 74
H
ft 160
50
200
400
600 400
600 240
200
180
m
3000
0 200
1-3NM 50/25B/C 70
230
H
H
m
220 ft
65
210 140 40 10 8 m 6 H4 S P2 N0 0 m 3/h 0 Q l/min
60 10 8 m 6 H 4 S P 2 N 0 0 m 3/h 0 Q l/min
30 ft 10 50 1000
100
2000
150
0 170 2800
72.959.11C
200 30
50 1000
100
2000
ft 10 0 150 170 2800 72.959.12C
559
51
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 200 83
0 Imp g.p.m.
400
200
600 400
600 270
1-3NM 50/25A/C 80
260
H m
H
250
75
ft 240 230
70 5
15
3
ft 5
4 m H 2 S P 1 N
0
0 m 3/h 0 Q l/min
50 1000
0 U.S. g.p.m.
100
800
0 Imp g.p.m. 400
150
2000 1200
800
35
0 170 2800
1600
0 U.S. g.p.m.
1200
40
1-3NM 65/16B/C
H
m 30
0 Imp g.p.m. 400
1200 800
1600 1200 130
1-3NM 65/16AR
H
110
800
120
m 35
100
H
110
H
90 ft
25
30
80
90
70
25
20 8 20 ft 10
6
H S P4 N
0 m 3/h 0 Q l/min
100 2000
200 3000 4000
300 5000
6000
m
0 U.S. g.p.m. 0 Imp g.p.m. 400
800
1200 800
2
400
1200
m 40
140 H
130 ft 120
35 110 100
30 8 m
20 ft 10
6
H S 4 P N
2
0 m 3/h 0 Q l/min
100 2000
200 3000 4000
300 5000
6000
0 m 3/h 0 Q l/min
100 2000
200 3000 4000
300 5000
6000
400
72.959.18C
1600
1-3NM 65/16A/C
H
20 ft 10
6
H S 4 P N
72.959.17C
45
80
8
m
2
ft 100
400
72.959.18C
560
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m.
800
0 Imp g.p.m. 400 48
1200 800
1600
0 U.S. g.p.m.
1200
52 150
50
m
140
H
40
130
1-3NM 65/20C/B
H
800
0 Imp g.p.m. 400
1200
1600
800
1200
170
1-3NM 65/20B/B 160
m 45
H
120 ft 110
150 H
140 ft 130
40
100
30 26 10 8 m 6 H S4 P2 N 0 0 m 3/h 0 Q l/min
100 2000
200 3000 4000
300 5000
6000
120
90
35
30
10 8 m 6 H4 S P2 N0
ft 10 0 400
30
0 m 3/h 0 Q l/min
100 2000
200 3000 4000
300 5000
6000
72.959.19C
0 U.S. g.p.m. 400 0 Imp g.p.m.
800
400
65
72.959.20C
0 U.S. g.p.m.
1200 800
1200
1-3NM 65/25C
58
800
0 Imp g.p.m. 400
1200
1600
800
210
1200 190
1-3NM 65/20A
H
m 60
ft 10 0 400
180
H
200
m 170
H
55
50 10 8 m H6 S4 P N2 0 0 m 3/h 0 Q l/min
180
160 ft 150
170
140
30
100 2000
200 3000
4000
300 5000
H
50
190 ft
ft 10 0 340
40 10 8 m 6 H 4 S 2 P N 0 0 m 3/h 0 Q l/min
30
100 2000
200 3000 4000
300 5000
6000
72.959.21C
72.959.22C
0 U.S. g.p.m. 400 0 Imp g.p.m.
400
800
1200
0 U.S. g.p.m. 400
800
1200
1-3NMS 65/250B
80 H
m
92
70
240 ft 230
400
800
1200 800
1200 300
1-3NMS 65/250A 290
H
250 H
0 Imp g.p.m.
90
260
75
m
H
85
280 ft 270
80
260
220 65 10 m8 6 H S4 P2 N 0 0 m 3/h 0 Q l/min
30
100 2000
200 3000
4000
300 5000
ft 10 0 400
ft 10 0 340
77 10 8 m 6 H S4 P2 N 0 0 m 3/h 0 Q l/min
72.959.23C
30 ft 10 100 2000
200 3000
4000
300 5000
0 340
72.959.24C
561
51
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 0 Imp g.p.m. 40
1000
1500
1000
2000 1500
0 U.S. g.p.m.
2500
0 Imp g.p.m. 46
2000 130
1-3NM 80/16B/C
H
m
1500
1000
2000 1500
2500 2000 150
1-3NM 80/16A/C
120 H
110 ft 100
30
1000
40
130
H
120
m
H
110 ft 100
90 80 20 8 m6 H4 S P2 N0 0 m 3/h 100 0 Q l/min 2000
30
90
70 ft 10 200 300 400 4000 6000
0 600 10000
500 8000
8 m6 H4 S P2 N0 0 m3/h 100 0 Q l/min 2000
80 ft 10 200 300 400 4000 6000
0 600 10000
500 8000
72.959.26C
0 U.S. g.p.m. 0 Imp g.p.m. 60
1000
1500
1000
2000
72.959.26C
0 U.S. g.p.m.
2500
1500
0 Imp g.p.m. 50
2000
1000
1500
1000
2500 2000 160
1-3NM 80/20B
180
H
2000 1500
190
1-3NMS 80/200A
150
H
m
m
140
170 H
50
H
40
160 ft 140
130 ft 120 110
130 40 10 8 m H6 S4 P N2 0 0 m 3/h 100 0 Q l/min 2000
30
200 300 400 4000 6000
ft 10 0 600 10000
500 8000
30 10 8 m 6 H 4 S P2 N0 0 m 3/h 100 0 Q l/min 2000
100 30
200 300 400 4000 6000
0 Imp g.p.m. 56
1000 1000
1500
2000 1500
72.959.27C
2500
0 U.S. g.p.m.
2000
0 Imp g.p.m. 68
180
1-3NM 80/25E 50
160 H
m
ft 150
30
100
10
30
6
ft 10 0 600 10000
200 300 400 4000 6000
500 8000
2000 1500
2500 2000 220 200 H
ft 140
H
m 50
120
0 0 m 3/h 100 0 Q l/min 2000
1000
1500
60
40
H S4 P2 N
1000
1-3NMS 80/250D
H
m8
ft 10 0 600 10000
500 8000
72.959.28C
0 U.S. g.p.m.
140
160 140
40 10 8 m 6 H S4 P2 N 0 0 m 3/h 100 0 Q l/min 2000
72.959.29C
30
200 300 400 4000 6000
500 8000
ft 10 0 600 10000 72.959.30C
562
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart 0 U.S. g.p.m. 0 Imp g.p.m. 78
1000
1500
1000
2000 1500
2500
0 U.S. g.p.m. 0 Imp g.p.m. 88
2000
1-3NMS 80/250C
1000 1000
1500
2000 1500
2500 2000
1-3NMS 80/250B
240
70
80
H
220
m
H
60
260 H
H
ft 240
m
ft 200
280
70 220
180 50 10 8 m 6 H S4 P2 N 0 0 m3/h 100 0 Q l/min 2000
60 10 8 m6 H4 S P2 N0 0 m3/h 100 0 Q l/min 2000
30
200 300 400 4000 6000
500 8000
ft 10 0 600 10000 72.959.31C
0 U.S. g.p.m. 100
0 Imp g.p.m.
H
1000 1000
1500
2000 1500
200 30
200 300 400 4000 6000
500 8000
ft 10 0 600 10000 72.959.32C
2500 2000
1-3NMS 80/250A
320
m 300
90
H
ft 280 80
72 10 8 m 6 H 4 S P2 N0 0 m 3/h 100 0 Q l/min 2000
260 240 30
200 300 400 4000 6000
500 8000
ft 10 0 600 10000 72.959.33C
51
563
BS. NM
Pressure boosting sets with 1 Centrifugal Pumps Fixed speed pump
Performance Mains: 400V 3~ Motor: 400V 3~ BS1F 1NM
32/16BE
BS1F 1NM BS1F 1NM
32/16A/A 32/20C/A
BS1F 1NM 32/20A/A BS1F 1NMD 32/210D/A BS1F 1NMD 32/210C/A BS1F 1NMD 32/210B/A BS1F 1NMD 32/210A/B BS1F 1NMD 40/180D/A BS1F 1NMD 40/180C/A BS1F 1NMD 40/180B/A BS1F 1NMD 40/180A/B BS1F 1NM 40/16B/B BS1F 1NM 40/16A/B BS1F 1NM BS1F 1NM
40/20B/A 40/20A/A
BS1F 1NM BS1F 1NM BS1F 1NM
40/25B/C 40/25A/C 50/16B/B
BS1F 1NM BS1F 1NM
50/16A/B 50/20B/C
BS1F 1NM BS1F 1NM BS1F 1NM
50/20A/C 50/25C/C 50/25B/C
BS1F 1NM BS1F 1NM BS1F 1NM
50/25A/C 65/16B/C 65/16AR
BS1F 1NM BS1F 1NM
65/16A/C 65/20C/B
BS1F 1NM BS1F 1NM BS1F 1NM
65/20B/B 65/20A 65/25C
BS1F 1NMS 65/250B BS1F 1NMS 65/250A BS1F 1NM BS1F 1NM BS1F 1NM
80/16B/C 80/16A/C 80/20B
BS1F 1NMS 80/200A BS1F 1NM 80/25E BS1F 1NMS 80/250D BS1F 1NMS 80/250C BS1F 1NMS 80/250B BS1F 1NMS 80/250A
Motor kW 1,5 2,2 3 4 4 5,5 7,5 9,2 4 5,5 7,5 9,2 3 4 5,5 7,5 11 15 5,5 7,5 9,2 11 11 15 18,5 11 15 15 15 18,5 22 22 30 37 15 18,5 22 30 22 30 37 45 55
HP 2 3 4 5,5 5,5 7,5 10 12,5 5,5 7,5 10 12,5 4 5,5 7,5 10 15 20 7,5 10 12,5 15 15 20 25 15 20 20 20 25 30 30 40 50 20 25 30 40 30 40 50 60 75
Pres. switch 1 bar min max 2,2 2,8 2,7 3,4 3,2 4,2 4,5 5,5 5 7 6 8 8 10 9,5 11 4 5,5 5 6,5 6,7 8,2 7,5 9 1,5 2,5 2,4 3,4 3,7 4,7 4,4 5,4 5,6 6,6 7,7 8,7 1,7 2,7 2,5 3,5 3,5 4,5 4,2 5,2 4,1 5,1 5,6 6,6 6,6 7,6 2,2 3,2 2,6 3,6 3,1 4,1 3 4 3,6 4,6 4,2 5,2 5 6 6,6 7,6 7,7 8,7 2,5 3,5 2 3 3,3 4,3 4,3 5,3 3,8 4,8 4,5 6 5,5 7 6,5 8 8 9
Maximum capacity * Q l/min
H m
Vessel Membrane litre
281 279 285 259 189 242 233 215 314 351 356 348 690 735 566 645 667 686 1171 1212 1087 1143 999 993 1175 2223 2238 2205 2101 2195 2238 1783 1812 1800 3391 2105 3040 3005 2465 2988 3091 3150 3094
22 28 33 46 51 61 82 97 41 51 68 76 15 24 38 45 57 78 17 25 36 43 42 57 67 22 27 32 31 37 43 51 67 78 25 20 34 44 39 46 56 66 82
500 500 500 750 500 500 750 1000 500 750 1000 1500 750 1000 1500 2000 3000 4000 2000 3000 3000 4000 4000 4000 5000 4000 5000 5000 -
* Maximum pumps flow at minimum setting pressure switch.
564
Vessel
800 1000 1000 1000 500 800 1000 1500 1000 1500 2000 2000 1500 2000 3000 4000 5000 4000 5000 5000 -
litre
BS. NM
Pressure boosting sets with 2 Centrifugal Pumps Fixed speed pump
Performance
BS2F Mains: 400V 3~ Motor: 400V 3~ BS2F 2NM 32/16BE BS2F 2NM 32/16A/A BS2F 2NM 32/20C/A BS2F 2NM 32/20A/A BS2F 2NMD 32/210D/A BS2F 2NMD 32/210C/A BS2F 2NMD 32/210B/A BS2F 2NMD 32/210A/B BS2F 2NMD 40/180D/A BS2F 2NMD 40/180C/A BS2F 2NMD 40/180B/A BS2F 2NMD 40/180A/B BS2F 2NM 40/16B/B BS2F 2NM BS2F 2NM
40/16A/B 40/20B/A
BS2F 2NM BS2F 2NM BS2F 2NM
40/20A/A 40/25B/C 40/25A/C
BS2F 2NM BS2F 2NM
50/16B/B 50/16A/B
BS2F 2NM BS2F 2NM BS2F 2NM
50/20B/C 50/20A/C 50/25C/C
BS2F 2NM BS2F 2NM BS2F 2NM
50/25B/C 50/25A/C 65/16B/C
BS2F 2NM BS2F 2NM
65/16AR 65/16A/C
BS2F 2NM BS2F 2NM BS2F 2NM
65/20C/B 65/20B/B 65/20A
BS2F 2NM 65/25C BS2F 2NMS 65/250B BS2F 2NMS 65/250A BS2F 2NM 80/16B/C BS2F 2NM 80/16A/C BS2F 2NM 80/20B BS2F 2NMS 80/200A BS2F 2NM 80/25E BS2F 2NMS 80/250D BS2F 2NMS 80/250C BS2F 2NMS 80/250B BS2F 2NMS 80/250A
Pres. switch 1 bar min max 2,2 2,8 2,7 3,4 3,2 4,2 4,5 5,5 5 7 6 8 8 10 9,5 11 4 5,5 5 6,5 6,7 8,2 7,5 9 1,5 2,5 2,4 3,4 3,7 4,7 4,4 5,4 5,6 6,6 7,7 8,7 1,7 2,7 2,5 3,5 3,5 4,5 4,2 5,2 4,1 5,1 5,6 6,6 6,6 7,6 2,2 3,2 2,6 3,6 3,1 4,1 3 4 3,6 4,6 4,2 5,2 5 6 6,6 7,6 7,7 8,7 2,2 3,2 2,8 3,8 3,3 4,3 4,3 5,3 3,8 4,8 4,5 6 5,5 7 6,5 8 8 9
Motor kW 1,5 x2 2,2 x2 3 x2 4 x2 4 x2 5,5 x2 7,5 x2 9,2 x2 4 x2 5,5 x2 7,5 x2 9,2 x2 3 x2 4 x2 5,5 x2 7,5 x2 11 x2 15 x2 5,5 x2 7,5 x2 9,2 x2 11 x2 11 x2 15 x2 18,5 x2 11 x2 15 x2 15 x2 15 x2 18,5 x2 22 x2 22 x2 30 x2 37 x2 15 x2 18,5 x2 22 x2 30 x2 22 x2 30 x2 37 x2 45 x2 55 x2
HP 2 x2 3 x2 4 x2 5,5 x2 5,5 x2 7,5 x2 10 x2 12,5 x2 5,5 x2 7,5 x2 10 x2 12,5 x2 4 x2 5,5 x2 7,5 x2 10 x2 15 x2 20 x2 7,5 x2 10 x2 12,5 x2 15 x2 15 x2 20 x2 25 x2 15 x2 15 x2 15 x2 20 x2 25 x2 30 x2 30 x2 40 x2 50 x2 20 x2 25 x2 30 x2 40 x2 30 x2 40 x2 50 x2 60 x2 75 x2
* Maximum pumps flow at minimum setting pressure of 2
nd
Pres. switch 2 bar min max 2 2,6 2,5 3,2 3 4 4 5 4,5 6,5 5,5 7,5 7,5 9,5 9 10,5 3,5 5 4,5 6 6,2 7,7 7 8,5 1,2 2,2 2 3 3,3 4,3 3,9 4,9 5,1 6,1 7,3 8,3 1,2 2,2 2 3 3 4 3,7 4,7 3,6 4,6 5,1 6,1 6,1 7,1 1,7 2,7 2,1 3,1 2,6 3,6 2,5 3,5 3,2 4,2 3,8 4,8 4,6 5,6 6,2 7,2 7,3 8,3 1,7 2,7 2,3 3,3 3 4 4 5 3,2 4,2 4 5,5 5 6,5 6 7,5 7,5 8,5
Maximum capacity * Q l/min
H m
Vessel Membrane litre
580 483 546 254 408 500 498 484 697 764 772 764 1410 1583 1227 1403 1452 1446 2609 2665 2466 2549 2236 2236 2426 4254 4111 4228 4422 4283 4044 3608 2970 2994 6712 6593 5836 5818 5691 6416 6407 6376 6400
20 25 31 41 46 56 76 92 36 46 63 71 12 20 34 40 52 74 12 20 31 38 37 52 62 17 21 27 25 33 39 47 63 74 20 23 31 41 33 41 51 61 76
500 500 500 750 500 500 750 1000 500 750 1000 1500 750 1000 1500 2000 3000 4000 2000 3000 3000 4000 4000 4000 5000 4000 5000 5000 -
Vessel
800 1000 1000 1000 500 800 1000 1500 1000 1500 2000 2000 1500 2000 3000 4000 5000 4000 5000 5000 -
litre
--
pressure switch.
51
565
BS. NM
Pressure boosting sets with 3 Centrifugal Pumps Fixed speed pump
Performance
BS3F Mains: 400V 3~ Motor: 400V 3~
Motor kW
BS3F 3NM
40/16B/B
BS3F 3NM BS3F 3NM BS3F 3NM
40/16A/B 40/20B/A 40/20A/A
BS3F 3NM BS3F 3NM
40/25B/C 40/25A/C
BS3F 3NM BS3F 3NM BS3F 3NM
50/16B/B 50/16A/B 50/20B/C
BS3F 3NM BS3F 3NM
50/20A/C 50/25C/C
BS3F 3NM BS3F 3NM BS3F 3NM
50/25B/C 50/25A/C 65/16B/C
BS3F 3NM BS3F 3NM BS3F 3NM
65/16AR 65/16A/C 65/20C/B
BS3F 3NM BS3F 3NM
65/20B/B 65/20A
BS3F 3NM 65/25C BS3F 3NMS 65/250B BS3F 3NMS 65/250A BS3F 3NM BS3F 3NM
80/16B/C 80/16A/C
BS3F 3NM 80/20B BS3F 3NMS 80/200A BS3F 3NM 80/25E BS3F 3NMS 80/250D BS3F 3NMS 80/250C BS3F 3NMS 80/250B BS3F 3NMS 80/250A
3 x3 4 x3 5,5 x3 7,5 x3 11 x3 15 x3 5,5 x3 7,5 x3 9,2 x3 11 x3 11 x3 15 x3 18,5 x3 11 x3 15 x3 15 x3 15 x3 18,5 x3 22 x3 22 x3 30 x3 37 x3 15 x3 18,5 x3 22 x3 30 x3 22 x3 30 x3 37 x3 45 x3 55 x3
HP 4 x3 5,5 x3 7,5 x3 10 x3 15 x3 20 x3 7,5 x3 10 x3 12,5 x3 15 x3 15 x3 20 x3 25 x3 15 x3 20 x3 20 x3 20 x3 25 x3 30 x3 30 x3 40 x3 50 x3 20 x3 25 x3 30 x3 40 x3 30 x3 40 x3 50 x3 60 x3 75 x3
* Maximum pumps flow at minimum setting pressure of 3
nd
Pres. switch 1 bar min max 2 2,6 2,7 3,4 3,9 4,7 4,4 5,4 5,6 6,6 7,9 8,7 1,9 2,7 2,7 3,5 3,5 4,5 4,2 5,2 4,1 5,1 5,6 6,6 6,7 7,7 2,2 3,2 2,6 3,6 3,1 4,1 3 4 3,6 4,6 4,2 5,2 5 6 6,6 7,6 7,7 8,7 2,2 3,2 2,8 3,8 3,3 4,3 4,3 5,3 3,8 4,8 5 6 6 7 7 8 8 9
Pres. switch 2 bar min max 1,6 2,2 2,3 3 3,5 4,3 4 5 5,2 6,2 7,5 8,3 1,5 2,3 2,3 3,1 3 4 3,7 4,7 3,6 4,6 5,1 6,1 6,3 7,3 1,9 2,9 2,3 3,3 2,8 3,8 2,7 3,7 3,3 4,3 3,9 4,9 4,7 5,7 6,3 7,3 7,4 8,4 1,9 2,9 2,5 3,5 3,1 4,1 4,1 5,1 3,4 4,4 4,5 5,5 5,5 6,5 6,5 7,5 7,6 8,6
pressure switch.
566
Pres. switch 3 bar min max 1,2 1,8 1,9 2,6 3,1 3,9 3,6 4,6 4,8 5,8 7,1 7,9 1,1 1,9 1,9 2,7 2,5 3,5 3,2 4,2 3,1 4,1 4,6 5,6 5,9 6,9 1,6 2,6 2 3 2,5 3,5 2,4 3,4 3 4 3,6 4,6 4,4 5,4 6 7 7,1 8,1 1,6 2,6 2,2 3,2 2,9 3,9 3,9 4,9 3 4 4 5 5 6 6 7 7,2 8,2
Maximum capacity * Q l/min
H m
Vessel Membrane litre
2115 2393 1879 2120 2189 2155 3971 4039 3894 3903 3524 3497 3563 6128 5831 6053 6622 6090 5410 5290 3590 3651 7854 8027 8491 8488 8818 9625 9610 9564 9323
12 19 32 37 49 72 11 19 25 33 32 47 60 16 20 25 24 31 37 45 61 72 16 22 30 40 31 41 51 61 73
750 1000 1500 2000 3000 4000 2000 3000 3000 4000 4000 4000 5000 4000 5000 5000 -
Vessel
1500 2000 3000 4000 5000 4000 5000 5000 -
litre
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS.. PUMPS Nos N. POMPE 1
BS1V
2
3
4
PUMP TYPE TIPO POMPE 5
6
BS2V
BS3V
BS4V
BS5V
BS6V
BS1V1F
BS1V2F
BS1V3F
BS1V4F
BS1V5F
NM 32/16BE NM 32/16A/A NM 32/20C/A NM 32/20A/A NMD 32/210D/A NMD 32/210C/A NMD 32/210B/A NMD 32/210A/B NMD 40/180D/A NMD 40/180C/A NMD 40/180B/A NMD 40/180A/B NM 40/16B/B NM 40/16A/B NM 40/20B/A NM 40/20A/A NM 40/25B/C NM 40/25A/C NM 50/16B/B NM 50/16A/B NM 50/20B/C NM 50/20A/C NM 50/25C/C NM 50/25B/C NM 50/25A/C NM 65/16B/C NM 65/16AR NM 65/16A/C NM 65/20C/B NM 65/20B/B NM 65/20A NM 65/25C NMS 65/250B NMS 65/250A NM 80/16B/C NM 80/16A/C NM 80/20B NMS 80/200A NM 80/25E NMS 80/250D NMS 80/250C NMS 80/250B NMS 80/250A
PP22 ForPer each pump pompa kW 1,5 2,2 3 4 4 5,5 7,5 9,2 4 5,5 7,5 9,2 3 4 5,5 7,5 11 15 5,5 7,5 9,2 11 11 15 18,5 11 15 15 15 18,5 22 22 30 37 15 18,5 22 30 22 30 37 45 55
HP 2 3 4 5,5 5,5 7,5 10 12,5 5,5 7,5 10 12,5 4 5,5 7,5 10 15 20 7,5 10 12,5 15 15 20 25 15 20 20 20 25 30 30 40 50 20 25 30 40 30 40 50 60 75
51
567
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions
Hv Hf
DN 2
h2
DN 1
h1
m1
L1
Connection Collettori BS1F 1NM BS1F 1NM
32/16BE 32/16A/A
BS1F BS1F BS1F BS1F BS1F
1NM 32/20C/A 1NM 32/20A/A 1NMD 32/210D/A 1NMD 32/210C/A 1NMD 32/210B/A
BS1F BS1F BS1F BS1F BS1F BS1F BS1F
1NMD 1NMD 1NMD 1NMD 1NMD 1NM 1NM
32/210A/B 40/180D/A 40/180C/A 40/180B/A 40/180A/B 40/16B/B 40/16A/B
BS1F BS1F BS1F BS1F BS1F
1NM 1NM 1NM 1NM 1NM
40/20B/A 40/20A/A 40/25B/C 40/25A/C 50/16B/B
BS1F BS1F BS1F BS1F BS1F BS1F BS1F
1NM 1NM 1NM 1NM 1NM 1NM 1NM
50/16A/B 50/20B/C 50/20A/C 50/25C/C 50/25B/C 50/25A/C 65/16B/C
BS1F BS1F BS1F BS1F BS1F BS1F BS1F BS1F BS1F BS1F
1NM 1NM 1NM 1NM 1NM 1NM 1NMS 1NMS 1NM 1NM
65/16AR 65/16A/C 65/20C/B 65/20B/B 65/20A 65/25C 65 /250B 65 /250A 80/16B/C 80/16A/C
BS1F BS1F BS1F BS1F
1NM 1NMS 1NM 1NMS
80/20B 80 /200A 80/25E 80 /250D
BS1F 1NMS 80 /250C BS1F 1NMS 80 /250B BS1F 1NMS 80 /250A
weight Peso
mm
DN 1
DN 2
Hv
Hf
h1
L1
m1
G2
G1
1045
875
175
625
365
G2
G1
1045
875
205
625
365
G2
G 1 1/4
1045
875
625
365
G2
G 1 1/2
1045
875
625
365
G 2 1/2 G 1 1/2
1045
875
175
625
365
G 2 1/2 G 1 1/2
1145
875 1145
205
625
365
G 2 1/2 G 1 1/2
-
-
-
-
-
G 2 1/2
G2
-
-
-
-
-
G 2 1/2
G2
-
-
-
-
-
G 2 1/2
G2
-
-
-
-
-
G3
G 2 1/2
-
-
-
-
-
G3
G 2 1/2
-
-
-
-
-
G3
G 2 1/2
-
-
-
-
-
100
80
-
-
-
-
-
100
80
-
-
-
-
-
100
80
-
-
-
-
-
* Cabinet version
568
135 155 155 175 135 155 155 175
kg
BS. NM
Pressure boosting sets with 1 to 3 Centrifugal Pumps Fixed speed pump or Variable speed pump (frequency converter)
Dimensions
DN 2
Hv Hf DN 1 h2
h1
L1
L2
B2
m1
Connection Collettori
TYPE BS2.. 2NM BS2.. BS2.. BS2.. BS2..
32/16BE
2NM 32/16A/A 2NM 32/20C/A 2NM 32/20A/A 2NMD 32/210D/A
BS2.. 2NMD 32/210C/A BS2.. 2NMD 32/210B/A BS2.. 2NMD 32/210A/B BS2.. BS2.. BS2.. BS2.. BS2..
2NMD 2NMD 2NMD 2NMD 2NM
40/180D/A 40/180C/A 40/180B/A 40/180A/B 40/16B/B
BS2.. 2NM BS2.. 2NM
40/16A/B 40/20B/A
BS2.. BS2.. BS2.. BS2.. BS2..
2NM 2NM 2NM 2NM 2NM
40/20A/A 40/25B/C 40/25A/C 50/16B/B 50/16A/B
BS2.. BS2.. BS2.. BS2.. BS2..
2NM 2NM 2NM 2NM 2NM
50/20B/C 50/20A/C 50/25C/C 50/25B/C 50/25A/C
BS2.. BS2.. BS2.. BS2.. BS2..
2NM 2NM 2NM 2NM 2NM
65/16B/C 65/16AR 65/16A/C 65/20C/B 65/20B/B
BS2.. BS2.. BS2.. BS2..
2NM 2NM 2NMS 2NMS
65/20A 65/25C 65 /250B 65 /250A
BS2.. 2NM BS2.. 2NM BS2.. 2NM
80/16B/C 80/16A/C 80/20B
BS2.. BS2.. BS2.. BS2.. BS2..
80 /200A 80/25E 80 /250D 80 /250C 80 /250B
2NMS 2NM 2NMS 2NMS 2NMS
B
BS2.. 2NMS 80 /250A
DN 1
DN 2
G3
G 21/2
G3
G 21/2
G3
G 21/2
G3
G 21/2
100
80
100
80
100
80
125
100
125
100
125
100
200
150
200
150
200
150
250
200
250
200
250
200
mm Hf 830 830 830 830 890 890 1370 1370 890 890 1370 1370 830 830 830 1310 1455 1455 975 1455 1455 1455 1455 1455 1455 1455 1455 1455 1455 1455 1655 1655 1655 1855 1455 1455 1655 1655 1655 1655 1855 1400* 1400*
Hv 1210 1210 1210 1210 1270 1370 1370 1670 1270 1370 1370 1670 1210 1210 1310 1310 1755 1755 1455 1455 1755 1755 1755 1755 1855 1755 1755 1755 1755 1855 1855 1855 1855 1600* 1755 1855 1855 1855 1855 1855 1600* 2100* 2100*
h1 165 165 195 195 245 272 272 307 245 272 272 307 187 187 215 215 340 240 315 215 315 215 340 240 240 320 320 220 340 240 260 360 260 310 340 240 360 260 360 260 310 310 310
h2
L1
345
385
365
385
380
460
460
475
380
480
400
500
440
500
435
515
455
515
480
515
525
625
550
625
575
625
615
730
640
730
670
730
* Cabinet version
569
weight Peso L2 330 370 395 395 420 440 440 515 415 435 435 510 395 395 425 425 540 615 425 425 540 540 545 620 620 540 540 615 615 615 725 725 725 975 620 620 725 725 725 725 975 1040 1110
m1
B
B2
235
600
625
235
600
625
550
700
800
550
700
800
550
820
800
550
820
800
-
820
-
-
820
-
-
820
-
-
820
-
-
1020
-
-
1020
-
-
1200
-
-
1050
-
-
1050
-
-
1200
-
kg
51