Criteria h9 0.5 x (Demister outlet diameter - Gas outlet nozzle diameter
LALL
h10
Min. 6" (Vendor to confirm.)
Bottom TL
Min. 24" (610mm) 2d Min. 12" (305mm) Min. 12" (305mm)
Outlet ND 3 A12
inch
Liquid outlet
305.0 Min. 12" (305mm)
NOZZLES LAL to LAH :
at Outlet volume flowrate Inlet Gas out. Liq. out.
Notes: (1) Fluid physical properties and operating conditions have been taken from HYSYS simulation. (2) K value as per GPSA (3) Piping Class is selected based on material & rating of Nozzle.
(Based on piping ID) (3) ID (mm) v (m/s) v² (kg/m/s²)
v³ (kg/s³)
Criteria
102.26
2.0
4 338
8 786
6000 kg/m/s²
A12
52.5
6.6
2 558
16 915
6000 kg/m/s²
A12
77.92
0.5
-
-
1.0m/s
ND
Piping Class
4 inch
A12
2 inch 3 inch
FUEL GAS SCRUBBER- Sizing Case ### ##
Vessel tag number Vessel designation Case
Gas outlet
036-V-0680 FUEL GAS SCRUBBER Design Capacity (7.5MMSCFD) - CASE 1 PROD YR 2014
By
SRK
Rev.
K01
Date
30/03/2010
ID
?DORIS Engineering 2007 - (v1.02)
OPERATING CONDITIONS Pressure 26.57 Bar g Temperature 43.12 °C
ID Inlet d
SCRUBBER DATA (L/D=3.22) 816 mm 102 mm
Outlet ND 4 B8
h1
inch (CS)
Vane Pack
h2 FLUID DATA (1) OUTLET GAS 7.5 MMSCFD 8 849 Sm³/h 7807 kg/h 20.9 g/mol 23.79 kg/m³
Standard flowrate (5) Mass flowrate Molecular weight Actual density
374.3 kmol/h
INLET LIQUID 8 641.1 0.0 2 0.7
Mass flowrate Actual density Actual vol. flowrate Actual vol. flowrate Outlet vol. Flowrate (3)
kg/h kg/m³ Am³/h Abbl/day Am³/h
Inlet ND 4 B8
h3 inch (CS)
h4 d
LAHH
h5 h6
GAS SECTION K (2) vg max value (m/s) 0.06 0.31
Area (m²) 0.52
vg (m/s) 0.17
vg/vgmax (%) 57%
Mini. height (mm)
2 236
H - TL/TL (mm)
2 626
LAH h7
NLL
h8
height
LIQUID SECTION Level Vol.
Dvol
Dt
(mm)
(mm)
(m³)
(m³)
(min)
h1 - To Gas outlet (6) Top TL h2 - Top Demister h3 - Bot. Demister h4 - Top Inlet device h5 - Bot. Inlet device h6 - LAHH LAH NLL h7 - LAL LALL Bottom TL
h9 0.5 x (Demister outlet diameter - Gas outlet nozzle diameter
LALL
h10
Min. 6" (Vendor to confirm.)
Bottom TL
Min. 24" (610mm) 2d Min. 12" (305mm) Min. 12" (305mm)
Outlet ND 2 B8
inch
Liquid outlet
305.0 Min. 12" (305mm)
NOZZLES at Outlet volume flowrate Inlet Gas out. Liq. out. Notes: (1) Fluid physical properties and operating conditions have been taken from HYSYS simulation. (2) K value as per GPSA (3) 17.5m3/d of Outlet Vol. Flowrate is considered as per Design Basis sec.6.4.20. (4) Piping Class is selected based on material & rating of Nozzle. (5) Design capacity of fuel gas system is 7.5MMSCFD. (6) Vessel top is ended with a body flange.
(Based on piping ID) (4) ID (mm) v (m/s) v² (kg/m/s²)