ENGINEERING REFERENCE
The content contents s of this document document are proprietary proprietary and confident confidential. ial. They are the property property of Ariel Ariel Corporation Corporation and may not be disclosed, disclosed, reproduced, reproduced, or used for for manufacture manufacture in part or in whole without written written permission from from Ariel Ariel Corporation.
Introduction to Packager Standards A succes successful sful reciproca reciprocating ting gas compress compression ion packag package e blends blends precision precision componen componentt selectio selection, n, fabricati fabrication, on, sale sales, s, and and servi service ce.. Ariel Ariel works works with with the the pack packag ager er to lead lead the the indu indust stry ry in perfo performa rmanc nce e as well well as reputa reputatio tion. n. This This standa standard rd is a minimu minimum m require requiremen mentt for pack packag aging ing quali quality ty.. Ariel Ariel enco encoura urages ges pack packag agers ers to exce exceed ed this this stand standard ard with the fines finestt quali quality ty packa packages ges.. The pack packag ager er must must confo conform rm to this this standa standard rd even even if it exce exceeds eds end user user spec specifi ifica catio tions ns.. Packager refers refers to any any party party inco incorpo rporat ratin ing g an Ariel Ariel produ product ct in the the manu manufa fact cture ure and/ and/or or asse assemb mbly ly of a compr compres essi sion on syste system. m. The pack package agerr must must ensure ensure that that the selec selected ted comp compres resso sorr is comp compati atible ble with the applic applicati ation on and and prope properly rly integ integrate rated d into into the gas gas compre compress ssion ion syste system. m. NOTE: This edition of the Packager Standards is based on current design, build, and practices for reciprocating compressor packages. These standards may not apply to previously built equipment and are subject to change without notice. Depending on the source, these standards may not be controlled copies. Visit www.arielcorp.com or contact Ariel for latest revisions.
Partial Scope Projects A partial partial scope scope project project is when any entity entity other other than the packager packager complet completes es any part of “package “package”” or compress compression ion system system assembl assembly. y. Regardl Regardles ess s of the scop scope e offere offered, d, the packa packager ger retains retains the obliga obligatio tion n to “pack “package age”, ”, instal install, l, and and commi commiss ssio ion n the compr compres esso sorr in acco accorda rdanc nce e with this this stand standard ard and and good good indus industry try pract practice ice.. At the bid bid phas phase, e, the the pack packag ager er must must clea clearly rly defi define ne the the scop scope e of supp supply ly,, iden identi tify fy area areas s of conc concern ern,, and and info inform rm the the purchase purchaserr of partial partial scope scope requiremen requirements. ts. Partial scope situations: situations: 1. The user user purch purchas ases es a comp complet lete e compr compres esso sorr syst system em or “pack “package aged” d” compre compress ssor or unit unit and choos chooses es to use use thei theirr own cons constru truct ctio ion n group group to inst instal alll it. it. In this this case case,, the the pack packag ager er must must guid guide e the the user user base based d on packag package e characte characteristi ristics. cs. At minimum, minimum, guidanc guidance e should should include include:: • Studies Studies requir required ed for found foundati ation on desig design n Anchor bolt bolt layo layout ut and eleva elevatio tions ns for off skid skid equip equipme ment nt and and piping piping • Anchor • Anchor Anchor bolt, bolt, sphe spheric rical al washer, washer, and and nut nut require requireme ments nts • Pre-grout alignmen alignmentt requiremen requirements ts • Groutin Grouting g best best practices practices • Direct involve involvement ment in commiss commissioni ioning ng 2. The user user purch purchas ases es an incom incomple plete te compr compres essi sion on syste system m without without key key comp compone onents nts such such as interinterconn connec ectin ting g pipin piping g and vess vessels els,, instrum instrumen entat tation ion,, drivers drivers,, contro controll syste systems ms,, or coole coolers. rs. At minimu minimum, m, packag packager er guidanc guidance e should should include: include: • Applicab Applicable le Ariel Packager Packager Standards Standards requiremen requirements ts • Correct Correct sizing sizing For the most recent edition of this document, visit www.arielcorp.com.
4
Transferreddocumen Transferreddocumentt from Framemakert Framemakert o Flare. Flare.
REV
Page 1 of 2
DESCRI PTI ON
REV 4
4
019144
10-25-13
3
015759
9-21-12
2
012316
9-3-04
1
ECN8 CN8541 541
2-16-16-0 01
0
EC N8 N8100
2-3- 00 00
REV
EC
DATE
REV
EC
DATE
ER-56.01
ENGINEERING REFERENCE
The contents of this document are proprietary and confidential. They are the property of Ariel Corporation and may not be disclosed, reproduced, or used for manufacture in part or in whole without written permission from Ariel Corporation.
• Applicable code requirements • Anchor bolt layout and elevations for off skid equipment and piping • Anchor bolt, spherical washer, and nut requirements • Pre-grout alignment requirements • Grouting best practices • Oversight and verification of compliance to Ariel Packager Standards • Direct involvement in commissioning
Ariel Contact Information Contact
Telephone
Fax
E-Mail
Ariel Response Center
888-397-7766 (toll free USA & Canada) or 740-397-3602 (International)
740-397-1060
[email protected]
740-393-5054
[email protected]
740-397-3856
--
740-397-0311
740-397-3856
Spare Parts Order Entry Ariel World HQ Technical Services
[email protected] [email protected]
Website: www.arielcorp.com
Ariel Response Center Technicians or Switchboard Operators answer telephones during Ariel business hours, Eastern Time - USA or after hours by voice mail. Contact an authorized distributor to purchase Ariel parts. Always provide Ariel equipment serial number(s) to order spare parts. The after-hours Telephone Emergency System works as follows: 1. Follow automated instructions to Technical Services Emergency Assistance or Spare Parts Emergency Service. Calls are answered by voice mail. 2. Leave a message: caller name and telephone number, serial number of equipment in question (frame, cylinder, unloader), and a brief description of the emergency. 3. Your voice mail routes to an on-call representative who responds as soon as possible.