Ericsson DUW Capacity DimensioningDescrição completa
Connection DiagramsFull description
Design Of bolt connection.Full description
Descripción completa
Example of structural steel connection
Full description
Descripción: chord
Full description
Ram
chord
Bolt Connection
Full description
moment connectionFull description
thesis
Descripción completa
you can download it from the RBS as b/m : open you explorer - type : http://169.254.1.1/EM/index.html or change the IP to be the RBS ip ——————————————— —————————— —————————— —————————— —————————— ————————— ———— 1. turn off your wifi. 2. make sure you have the ip address of the DUW, I always put the default gateway address for example: ip address: 169.254.1.1 subnet mask: 255.255.0.0 default gateway: 169.254.1.2 this is, most of the time, the default ip address. if you still could not connect to the DUW, try to access the DUW through hyper terminal (or any telnet programs i.e putty). Install new element manager for DUW and change date in ur laptop jan 2010 —————————— ————— —————————— —————————— —————————— —————————— ————————— ———— If your pc/laptop is using an anti-virus program like symantec, norton, norton, etc... you have to disable it temporarily to allow connection on the UDP/TCP/I UDP/TCP/IP P ports. Also, make sure your windows firewall does not block the amos/emas program and ports 21,22,23, 80, 56834, 56836 etc... Switch off your WIFI/Bluetooth. Setup up your PC/laptop ethernet LAN card with the following settings: DUW RBS site LAN ip address: 169.254.1.1 ip address: 169.254.1.10 <-- THIS IS YOUR PC's etherent LAN ip address subnet mask: 255.255.0.0 default gateway: 169.254.1.10 Note: if .10 doesn't work, try .2. Do not use 169.254.1.1 as an ip address of your laptop's ethernet LAN ip address because this is the default RBS site LAN ip address. Doing so will create collision with the DUW's ip address and you will not be able to connect to the DUW. Connect ethernet LAN cable to your pc and DUW, try to ping: open cmd in MS-DOS window: ping 169.254.1.1 If you cannot still connect, connect to the DUW via RS-232 serial cable and set the ip address: Connect your client with the serial line cable to the Test port on the CBU or connect to the LMT A port on the DUW. The serial connection in the client is configured using the following parameters: ■baud rate = 9600 bits per second ■parity = none ■stop bits = 1 bit ■data bits = 8 bits ■flow control = none reload -[ENTER] ifconfig [ENTER] ifconfig le0 169.254.1.1 netmask 255.255.0.0 [ENTER] ifconfig [ENTER] reload [ENTER] Try to connect again. Once you are connected, download download the EMAS installation so that you don't have compatibility issues when loading your scripts. Ensure you have the correct java j2re1.5.0_1 j2re1.5.0_12 2 or later installed in your pc. Open internet explorer and copy-paste this link: http:///em/index.html node>/em/index.html If you still cannot connect, replace the DUW. —————————— ————— —————————— —————————— —————————— —————————— ————————— ———— Dear go to the site and open putty ang put some commandreload -- EnterThen RBS restart after stable, but fan sound very high.Type:Ifconfig Le0 169.254.1.1 netmask 255.255.0.0 255.255.0.0 EnterThen type ifconfig enter and check ip configured or not if configure. Then use this ip 169.254.1.1 for open EM