Required casing slips setting load Write only in to the
coluor cells!
Casing nominal weight (Gcas):
68.6 68.6 kg/m kg/m
Wellhead prodacion temperature (to1):
60 C
Wellhead temperature during the job (to2):
25 C
Drilled depth (L1):
2069 m
Expected TOC in annulus (L2):
500 m
Bottomhole Temperature (t1):
94 C 664 t
Casing body yield strength :
F= L2*Gcas+33*DT*Gcas DT= ta -tb T= to + (t1-to)L2/2L1 TOC Free casing in an annulus lus static tic av avarage (L2) temperature (ta) 500 m 550 m 600 m 650 m 700 m 750 m 800 m 850 m 900 m 950 m 1000 m
33.3 C 34.1 C 35.0 C 35.8 C 36.6 C 37.5 C 38.3 C 39.1 C 40.0 C 40.8 C 41.6 C
Free casing prodactio tional av avarage temperature (tb) 64.1 C 64.5 C 64.9 C 65.3 C 65.7 C 66.1 C 66.5 C 66.9 C 67.3 C 67.8 C 68.2 C
Free casing Casing slips avarage te temp. requir uired se settin ting difference (DT) load (F) 30.8 C 30.3 C 29.9 C 29.5 C 29.1 C 28.7 C 28.2 C 27.8 C 27.4 C 27.0 C 26.5 C
The casing slips setting load can NOT be more than 50%-a of the casing body yield strength !!
104 t 106 t 109 t 111 t 114 t 116 t 119 t 121 t 124 t 126 t 129 t
Stucked string free point calculation Write only in to the