DCY2.781.SUPORUPSS/V1.0/E-E
SuporUp Computer Data Processing Software
OPERATION MANUAL
CONTENTS
CONTENTS 1.
2.
3.
4.
Introduction………………………………………………………………………….
1-1
1.1
Overview……………………………………………………………………….........
1-1
1.2
Scope……………………………………………………………………………....
1-1
1.3
Purpose………………………………………………………………………….....
1-1
1.4
Background……………………………………………………............................
1-1
1.5
Operating Environment…………………………………………........................
1-1
1.6
Product Delivery Description……………………………………….....................
1-2
System Installation and Software Interface………………………………………
2-1
2.1
Installation and Uninstall………………………………………………………….
2-1
2.2
Software Screen.……………………………………………………………………
2-3
2.3
Introduction of Menus and Shortcuts……………………………………………
2-4
Operation of PA Files…………………………………………………………….....
3-1
3.1
Open and Close Files………………………………………………………………
3-1
3.2
Toolbar Features………………………………………………………………….
3-3
3.3
Image Measurement………………………………………………..……………...
3-11
3.4
Introduction of Corrosion Image……………………………..……..……………..
3-17
Operation of TOFD Files…………………………………………………………...
4-1
4.1
Open and Close Files…………………………………………………………….
4-1
4.2
Change Imaging Direction…………………………………………………………
4-2
4.3
LW Reference Line Setup…………………………………………………………
4-2
4.4
Color Scale Setup…………………………………………………………………..
4-3
4.5
Toolbar Features……………………………………………………………………
4-3
4.6
TOFD Image Measurement………………………………………………………..
4-8
5. Operation of Conventional UT Files……………………………………………..
5-1
5.1
Open and Close Files………………………. …. …. ……….……………………
5-1
5.2
Image Layout……………….……………………………………………………….
5-2
5.3
Zoom Image………………………………………………………………………...
5-3
5.4
Color Scale Selection……………………………………………………………..
5-3
5.5
Toolbar Features………………………………………………………………........
5-3
5.6
Image Measurement………………………………………………………….........
5-6
5.7
Record and Play Conventional UT Cine……………………………………........
5-9
I
CONTENTS
6.
Operation of TG Files……………………………………………………………….
6-1
6.1
Open and Close Files…………………………………………………………….
6-1
6.2
ColorAndLine Setup……………………………………………………………….
6-2
6.3
Thickness Reading Area………..…………………………………………………
6-3
6.4
Disposal……………………………………………………………………………...
6-3
Test Report………………………………………………...………………………….
7-1
7.1
Template Manager………………………………………………………………….
7-1
7.2
UserInfo Manage……………………………………………………………………
7-4
7.3
Generate Report……………………………………………………………………
7-5
7.4
Report Now………………………………………………………………………….
7-6
Software Maintenance…………………………………...………………………….
8-1
8.1
Software Upgrade…………………………………………………………………
8-1
8.2
Telephone or E-mail Enquiry………………………………………………………
8-1
8.3
SIUI Service Contact Information…………………………………………………
8-1
Appendix A: Keywords for General Info in Reports…...…………………………….
A-1
Appendix B: Keywords for Phased Array and Corrosion Report…………………
B-1
Appendix C: Keywords for TOFD Report…………………….………………………..
C-1
Appendix D Keywords for Conventional UT Report……….………………………..
D-1
Appendix E Keywords for TG Report…………………….……………………………
E-1
7.
8.
DCY2.781.SUPORUPSS/V1.0/E-E
II
Introduction
Chapter 1 Introduction 1.1 Overview SuporUp computer data processing software is professional software for industrial ultrasonic data processing system by Shantou Institute of Ultrasonic Instruments Co., Ltd. (SIUI), which needs to be installed on a computer before use. SuporUp software provides a convenient approach for post-processing of industrial ultrasonic data.
1.2 Scope Mainly used for acquisition, display, measurement, processing and report generation of industrial ultrasound data.
1.3 Purpose This manual is a detailed description of the "SuporUp Computer Data Processing Software". For brief description, "SuporUp" is used as a short form.
1.4 Background The initial release version of SuporUp is V1.00.0, and the subsequent updates are based on this version, with incremented version number.
1.5 Operating Environment The SuporUp software can run on Windows XP/ 7 operating system.
1-1
Introduction
1.6 Product Delivery Description Installation CD (or USB disk, portable hard disk) and operation manual.
1-2
System Installation and Software Interface
Chapter 2 System installation and Software Interface 2.1 Install and Uninstall 2.1.1 System Installation Double click the installation file icon (see Fig. 2-1) to start installing SuporUp software. Follow the prompts to finish installation.
Fig. 2-1 Installation File Icon ★Tip: The default installation directory is "Administrator \ SIUI \ SuporUp" in the directory of the installation package. For example, the installation package is placed in the root directory of D drive, therefore the default installation directory is "D: \ Administrator \ SIUI \ SuporUp." For some versions of Win7, such as Home Basic version, due to the safety setting of Win7 operating system, the software functions may not be used properly after software installation to the system drive. In such case, please reassign the software installation directory to a non-system drive directory. 2.1.2 Uninstall the Software Click Start menu -> Program menu and select SIUI\SuporUp, and then click Uninstall to uninstall the software. Or select Add/Remove Program from the Control Panel to uninstall the software
2-1
System Installation and Software Interface
2.1.3 Start the software Find the software shortcut icon on desktop as shown in Fig. 2-2. Double click the shortcut icon to start the software, or click Start menu -> Program menu, select SIUI\SuporUp, and then click SuporUp to start the software.
Fig. 2-2 SuporUp Shortcut 2.1.4 Exit the software Click X at the top right of the screen to exit the software. If the current file is changed, the system will automatically prompt whether to save the file. See Fig. 2-3.
Fig. 2-3 Confirm to save or not After confirming to save or not, the system prompts whether to close the window. Click Yes to exit.
Fig. 2-4 Confirm to close or not
2-2
System Installation and Software Interface
2.2 Software Screen The software screen is shown in Fig. 2-5, and the meaning of each area is shown in Table 2-1. 1
2
3
4
Fig. 2-5 Software Screen Table 2-1 Information in Software Screen Areas No.
Item
Function Operation menus and some shortcut menus for the software.
1
Menu Bar
The menu displays vary subject to the opened file (PA files, TOFD files, and corrosion CScan).
2
Image Display
To display the images; Multi-window may display multiple images simultaneously. FileParameter displays the opened file directory, name and
3
File Parameter and Toolbar
parameters. To display the opened file directory and name (click it to hide the window). Toolbar displays the tools available for the file.
4
MeasureView
To display measurement result of each file, and multiple measurements can be displayed. 2-3
System Installation and Software Interface
2.3 Introduction of Menus and Shortcuts 2.3.1 Menu Depending on the file opened, the operable menus are displayed in the menu bar, as shown in Fig. 2-6 and Fig. 2-7.
Fig. 2-6 Menu Bar of PA File
Fig. 2-7 Menu Bar of TOFD, UT, TG and Corrosion Scan Files 2.3.1.1 File Menu The File menu is for opening and closing files, and also for viewing or clearing history files and exiting the software, as shown in Fig. 2-8.
Fig. 2-8 File Menu The software compatible file formats are in Table 2-2. Table 2-2 Software compatible file formats No.
File Type
File Format
1
PA full record file
.prec
2
PA parameter file
.pdat
3
TOFD full record file
.trec
2-4
System Installation and Software Interface
No.
File Type
File Format
4
TOFD parameter file
.tdat
5
Conventional UT BScan clip file
.urec
6
Conventional UT parameter file
.udat
7
TG dataset
.tgdat
8
TG parameter file
.tgpar
2.3.1.2 Measure Menu The measure menu is for file data measurement and calculation. The measure menus are different subject to file types. See Fig. 2-9, Fig. 2-10 and Fig. 2-11.
Fig. 2-9 Measure menu of PA files and corrosion CScan files
Fig. 2-10 Measure menu of TOFD files
Fig. 2-11 Measure menu of Conventional UT Files 2.3.1.3 Report menu Use the SuporUp software for file processing, measurement and calculation, and the results can automatically generate reports based on customer needs. The report template can be the system default template, or a custom template. See Fig. 2-12 for the specific operation of report generation, see Chapter 7 Report.
2-5
System Installation and Software Interface
Fig. 2-12 Report menu 2.3.1.4 Remark The Remark menu includes 2 remark types: Mark and Ring. 1) Mark menu allows text mark on images. Use the mouse to hold and drag the box and adjust its size and location. Double-click the box to input text directly. Use the mouse to select the box, press Delete or BackSpace on the keyboard to delete it. 2) Ring menu can be used with the text to circle the image section needs to be highlighted. Use the mouse to hold and drag the box and adjust its size and location. Use the mouse to select the box, press Delete or BackSpace on the keyboard to delete it.
Fig. 2-13 Remark menu 2.3.1.5 Layout menu ★ Tip: For PA files only. The layout menu is for setting view layout. Check the desired view option, or uncheck to cancel the view display. See Fig. 2-14.
Fig. 2-14 Layout menu View R is a simulated workpiece view accordingly to the PA file workpiece information. 2-6
System Installation and Software Interface
Subject to user inspection and analysis needs, select the item to be displayed. If there are two or more groups of PA files, select the group to check View R or Total View R. 2.3.1.6 Capture menu The user may capture images, and the Capture can be displayed in the report or printed. See Fig. 2-15.
Fig. 2-15 Capture menu 1) Window Capture Window Capture is a capture of the selected window, including menu bar. Click Capture -> Window Capture or the hotkey Capture, the system automatically captures and saves it, and pops up the window of save path. 2) Rectangle Capture Rectangle Capture is a capture of the selected rectangle. Click Capture -> Rectangle Capture, and place the mouse at the start of the capture. Long press it and drag the mouse to select the rectangular range. Release the mouse to finish capture. 3) TOFD Capture ★ Tip:For TOFD files only. TOFD Capture is a capture of the full TOFD image, not including the menu bar. Click Capture -> TOFD Capture, and the system automatically captures and saves it, and pops up the window of save path. 4) CaptureDirectory Use CaptureDirectory to open the saved capture folder and review capture files. 2.3.1.7 Setup menu The users may set up Line and Color to be displayed in the software according to their preferences, making it easier to view and analyze. Depending on the file type, the options of the setup menu may vary. See the detailed description of setup menu below.
2-7
System Installation and Software Interface
1) ColorAndLine For setting Color, Line, FontSize, font background color, font background opacity, and color range for the software screen. Set Fig. 2-16 for the PA file setup screen.
Fig. 2-16 Color and Line Setup Window a) Line and FontSize can be selected from the drop-down menu, with a number of steps available. b) Color setup: click on the color box, the system will automatically pop up the color selection window, and the user may choose according to their color preferences, or customize other colors. See Fig. 2-17.
Fig. 2-17 Color selection window 2-8
System Installation and Software Interface
c) The color range of color rank can be customized. Use the mouse to click on Color Rank in the menu bar, and the system will automatically pop up the color rank setup screen. See Fig. 2-18.
Fig. 2-18 Color rank setup window
Begin Point, Last Point: The users may customize the color of begin point, last point or any point in between. Confirm the selected color, and the color rank at the screen top will automatically display the color gradient range according to user selection.
Delete Point: Click the mouse in any of the range of the color rank to change the color. Now the selected color is the inserted gradient color to the color rank, without changing the colors of the start and finish positions of the color rank. Multiple color points can be inserted at the same time to the color rank. Click and drag the right arrow of the color point, and you may change the position of color point, and click Delete Point to delete the inserted color point.
New Empty: To create a new color rank, click New Empty with the mouse.
Save: Click Save to save the current color rank, and the saved color rank will be displayed in the column of Color Rank, and displayed in the drop-down menu of Color Rank in ColorAndLine setup screen for selection. 2-9
System Installation and Software Interface
Delete: To delete the color rank, move the mouse cursor to check in the box in front of the color rank, then click Delete button. Import: select and import a color rank file to SuporUp for use.
Apply: Apply the color settings to the image, and set the window unclosed. Default: Reset the setup to the system default color setup. Exit: exit the setup window. Closing the window may exit the setup. The system will save the last edited color rank temporarily for change upon the next access. 2) Unit Subject to user habit, set up the measure length unit for the software, with mm and inch available.
Fig. 2-19 Units Menu 3) Language Currently the software supports languages of Chinese, English, Russian and Hungarian for user setup.
Fig. 2-20 Language Menu 2.3.1.8 Help Menu The menu includes Rectangle Capture Help and Operation Manual, as shown in Fig. 2-21. Click Rectangle Capture Help to bring up simple operation steps window for rectangle capture. Click Operation Manual to review the electronic operation manual (the user computer needs to be installed with the software for opening PDF file).
Fig. 2-21 Help menu 2-10
System Installation and Software Interface
2.3.1.9 About The About menu displays information about software version and modules.
Fig. 2-22 About menu 2.3.2 Description of Hotkeys For easy user operation, some of the frequently used menu options can be found in the shortcut menu bar. Just simply click on the shortcut to perform the operation. See Table 2-3. Table 2-3 Hotkeys No.
Hot Key
Functional Description
1
Open
2
Save
3
Save as
4
Close
5
Capture
6
Report 2-11
System Installation and Software Interface
No.
Hot Key
Functional Description
7
ColorAndLine
8
Remark
9
Measure Rectangle
10
A Gate, B Gate, C Gate, for measuring /
A-scan echoes
/
(for UT and PA files only) 11
Landscape (for corrosion, UT and TOFD files only) Portrait
12
(for corrosion, UT and TOFD files only) 13
Zoom Reset
14
Color Scale Change Layout
15 (for corrosion and TOFD files only) Save Layout 16 (for corrosion and TOFD files only)
2-12
Operation of PA Files
Chapter 3 Operation of PA Files 3.1 Open and Close Files 3.1.1 Open A File Start SuporUp. There are 3 ways to open a file. 1) Select File -> Open from the menu. 2) Press the hotkey Open, 3) Select "+ File” from the FileParameter window on the right. Find the directory storing SUPOR or SyncScan instrument files from the pop-up window, and then double click the phased array (PA) file with the suffix *.prec to open it. See Fig. 3-1. ★Tip: The user can open multiple PA files in the software at the same time.
Fig. 3-1 Example of Opening A PA File 3-1
Operation of PA Files
When the file is opened, the user may set up the view of image window display in Layout menu. Each group of images can be set up to display: 3 A-scan views, 1 B-scan view, 1 [B] scan view,1 C-scan view, 1 D-scan and 1 R-scan view at maximum. See the description for the different views below. Table 3-1 View Description No.
View
Description
1
A
A scan line displayed in A-Scan, with the horizontal axis for sound path, and the vertical axis for amplitude.
2
B
Workpiece side view. Multiple A-scan lines displayed at the actual echo positions after volume correction, with the horizontal axis for the distance between the probe reference point and the workpiece reference point (or probe width), and the vertical axis for depth.
3
C
Workpiece top view. Acquired from data processing in the width (horizontal) direction by multiple B images, with the horizontal axis for probe moving distance or time, and the vertical axis for beam width or coverage width (horizontal).
4
D
Workpiece end view. Acquired from data processing in the depth (vertical) direction by multiple B images, with the horizontal axis for probe moving distance or time, and the vertical axis for depth coverage.
5
R
Ray tracing diagram.
6
[B]
A 2D image generated in time or distance axis by the same A-scan echo, with the amplitude displayed in color codes, the horizontal axis for distance or time, and the vertical axis for depth.
Click and drag the border of each view to change the display position of that view. Click the submenu in Layout, for example PA Group 1, to open or close all views in PA Group 1. Or go to its second-level menu, click to select the desired view. Click To instrument Layout, and the view method of the image window is restored to the system view method when the record file was saved. 3-2
Operation of PA Files
3.1.2 Close A File There are 3 ways to close a file. 1) Select File -> Close, and select the desired file name to close the file. 2) Click the hotkey Close to close the file directly. 3) Select - All or Checked from the file parameter window to close it. 【Note】:Select "- All" to close all files; Select “Checked” to close the checked file only, after using the mouse to click the file to be closed.
3.2 Toolbar Features The menu bar above the image is general menu settings for all files. See Chapter 2 for details. The toolbar features for different file types may vary. See the figure below for the toolbar of PA files. 【Note】:Click Toolbar to hide the toolbar menu.
Fig. 3-2 3.2.1 Play
(1) Click the play button
(2) Click the stop button
to play back images automatically.
or
to to pause or stop playing.
(3) Adjust the playback speed by using the fast-forward button 3-3
or rewind button
Operation of PA Files
, and the playback speed will be updated simultaneously. Or when in stop state place the mouse at the play slider
, hold the left button and slide, and images are
played at the slide speed. Release the button to stop playback. See Fig. 3-3.
Fig. 3-3 Play Adjustment 3.2.2 DigitalGain The image gain range is -20.0dB~20.0dB, with the step 0.5dB. Use the menu DigitalGain to make adjustment. See Fig. 3-4.
Fig. 3-4 Gain Adjustment 3.2.3 DataSource When View C is generated from 0° lines, select Depth or Amplitude to display View C.
Fig. 3-5 Data Source Selection 3.2.4 ImageProcess Image processing of "Zoom Reset" and "Color Scale Setup" for PA files. 【Note】:“Color Scale Setup" is not available for View A. 3-4
Operation of PA Files
Fig. 3-6 Image Processing 3.2.4.1 Zoom 【Note】:Two types of image zoom available. The "Zoom Reset" button is for local zoom only. 1)
Full screen zoom: to enlarge the image to the entire image display window. Double click the title bar of the image view to enlarge the image window to the maximum screen, while other images are automatically hidden. Double click the title bar again to restore the original size.
2)
Local zoom: Click the left mouse button on the position to be enlarged on the image. Long press and drag to the desired magnified area and then release the mouse. The selected area is zoomed out automatically to the view window. To zoom out to the original image size, click "Zoom Reset".
3.2.4.2 Color Scale Setup When the cursor stays on View B, [B], C or D, the "Color Scale Setup" button will appear. The user can set up or change the image color scale. See 2.3.1.7 1) "ColorAndLine” for the edit of color scale. Double left click the color scale in the image window and quick access to color scale setup. 3.2.5 Zoom Type According to the zoom type setup, the image is adjusted automatically to the display. Image B/[B]/C/D supports the zoom types below. If the scan mode is time-based, the image [B]/C/D does not support FitHorDir and dFitVerDir. 【Note】:Clicking the right mouse button on the view to display the menu.
3-5
Operation of PA Files
Fig. 3-7 Zoom Type FitHorDir: The image is zoomed in horizontal direction. FitVerDir: The image is zoomed in vertical direction. FitSize: The image is zoomed in any type (without proportional restriction). System: Consistent with image generation. 3.2.6 Display The menu items for different views are not the same. The user may check the menu items to be displayed as required. 【Note】: Click the right mouse button on the view to display the menu. 3.2.6.1 View A See Table 3-2 for the menu items displayed in View A. Table 3-2
Menu items displayed in View A
No.
Item
Description
1
Gate A/B/C
Set up whether to display gate A/B/C and the measurement information at the top right of the view window.
2
EchoSoundPath
Echo sound path measurement in the gate displayed at the top right of the view window.
3
EchoDepth
Echo depth measurement in the gate displayed at the top right of the view window.
4
EchoHorDistance
Echo horizontal distance measurement in the gate displayed at the top right of the view window.
5
EchoAmplitude
Echo amplitude measurement in the gate displayed at the top right of the view window.
6
HdB
HdB measurement in the gate displayed at the top right of the view window. 3-6
Operation of PA Files
No.
Item
Description
7
Peak
Set the gate measurement mode to “Peak" in the view window.
8
Flank
Set the gate measurement mode to “Flank" in the view window.
9
JFlank
Set the gate measurement mode to “JFlank" in the view window.
10
AppendLine
Two append lines displayed in the view window, with the live measurements (depth) of the two append lines displayed at the top right of the window.
3.2.6.2 View B See Table 3-3 for the menu items displayed in View B. Table 3-3 No.
Item
Menu items displayed in View B
Description For selecting the B image display area in View C and
1
CDSelection
2
WeldOverlay
3
GateMode(SoundPath)
4
GateMode(Depth)
Set GateMode of View B to Depth.
5
DispGate
Set up whether to display the gate.
6
MeasureLine
7
MeasureNum
8
View D. Set up whether to display the weld overlay simulation. Set GateMode of View B to SoundPath.
Display/close the measure line. When the measure line moves, the data on the measure line is displayed real-time. Refers to A1/A2/A3 window append line. The default is
A1/A2/A3 AppendLine
A1 AppendLine enabled. When A1 AppendLine is recorded, the scanline displayed in B image record is "A1ML1 / A2ML2".
The C/D scan select box is for selecting the display area in CScan and DScan views for the selected B image. After readjusting the scan select box, the CScan and DScan views will be automatically updated. Move the mouse cursor to the edge of the select box, and the mouse arrow becomes a double-arrow cursor. Press and hold on the right mouse button and move it to change the 3-7
Operation of PA Files
size of the select box, as shown in Fig. 3-8 and Fig. 3-9.
Fig. 3-8 Adjust the Size of Select Box
Fig. 3-9 Adjust the Size of Select Box Move the mouse cursor to the center of the select box, and the mouse cursor becomes a four-way cursor. Press and hold on the right mouse button, and move it to change the position of the select box as shown in Fig. 3-10.
Fig. 3-10 Adjust the Position of Select Box 3.2.6.3 View [B] See Table 3-4 for the menu items displayed in View [B].
3-8
Operation of PA Files
Table 3-4
Menu items displayed in View [B]
No.
Item
Description
1
Gate
Display/close the gate.
2
MeasureLine
Display/close the measure line.
3
MeasureNum
When the measure line moves, the data on the measure line is displayed real-time.
3.2.6.4 View C See Table 3-5 for the menu items displayed in View C. Table 3-5 No.
Menu items displayed in View C
Item
Description
1
MeasureLine
Display/close the measure line.
2
MeasureNum
When the measure line moves, the data on the measure line is displayed real-time.
3
CenterLine
Display/close the center line.
3.2.6.5 View D See Table 3-6 for the menu items displayed in View D. Table 3-6 No.
Menu items displayed in View D
Item
Description
1
MeasureLine
Display/close the measure line.
2
MeasureNum
When the measure line moves, the data on the measure line is displayed real-time.
3
Workpiece
Set up whether to display the workpiece thickness indication
Thickness
line.
3.2.6.6 View R See Table 3-7 for the menu items displayed in View R.
3-9
Operation of PA Files
Table 3-7 No.
Menu items displayed in View R
Item
Description
1
Probe
Set up whether to display the probe.
2
Distance M
Set up whether to display Distance M.
3
HeatAffectZone
Set up whether to display the HeatAffectZone of the workpiece.
4
SoundBeam(Wedge)
Set up whether to display sound beam in the wedge.
5
SoundBeam(Workpiece)
Set up whether to display sound beam in the workpiece.
6
Gate A/B/C
Set up whether to display the gate on the sound beam.
7
Measure Point
Set up whether to display the Measure Point.
8
Depth
Set up whether to display the depth of the measure point.
9
Distance E
Set up whether to display the distance from the PA probe flank or wedge flank to the weld center.
10
Echo 1~N
Set up the maximum number of echoes displayed by sound beam.
11
SoundBeamEndPosition(Echo)
Set up SoundBeamEndPosition to the echo number.
12
SoundBeamEndPosition(Gate)
Set up SoundBeamEndPosition to the gate end position.
13
SoundBeamEndPosition(Measure
Set up SoundBeamEndPosition to measure
Point)
point position.
3.2.7 Sync In the Sync menu, select MeasureLine, and the measure lines in other images will be synchronized when adjusting the measure lines in View B, [B], C or D.
3-10
Operation of PA Files
3.3 Image Measurement 3.3.1 Measure line adjustment 1) Adjust the horizontal or vertical measure line individually: Left click the horizontal or vertical measure line to activate the measure line (displayed in a dotted line). Move the mouse to the measure position and then click the left mouse button again, The horizontal or vertical measure line adjustment is finished. 2) Adjust the horizontal or vertical measure line simultaneously: Click the intersection of the horizontal and vertical measure lines to activate the measure lines (displayed in a dotted line). Move the mouse to the measure position and then click the left mouse button again. The horizontal and vertical measure lines adjustment is finished. 3.3.2 A-Scan image measurement 3.3.2.1 Measurement menu After selecting the A-scan image window, click Toolbar -> Display to select the measure item; or right-click the A-scan image window and select the measure item from the pop-up window. 3.3.2.2 Measurements Up to three measurement gates can be displayed at the same time in the A-Scan image window. (1) Gate width adjustment. Place the cursor on any gate. Left click when the cursor changes to a double arrow, and the gate is being selected (dotted line). Move the mouse to adjust the gate size, and left click to confirm. (2) Gate position adjustment. Place the cursor in the middle of the gate. Left click when the cursor changes to a four-way cross cursor, and the gate is being selected (dotted line).Move the mouse to adjust the gate size, and left click to confirm. After the gate adjustment is finished, select Measure -> AWave Echo for the gate, and you may perform measurement for the gate; or click the gate measurement icon Gate in 3-11
Operation of PA Files
the hotkey menu bar to finish measurement quickly. Now the number (1, 2, ......) displayed at the gate refers to the number of measurement. The measurement result is displayed on the right of the AScan image, with the font color corresponding to the gate line color. See Fig. 3-11. Measurement Number of measurement
Fig. 3-11 Gate measurement example of A-Scan image 3.3.3 B/[B]/C/D Image Measurement The measurement steps of a B/[B]/C/D image is as follows: 1) There are two cross measurement cursors on each of the three window (see Fig. 3-12). Left click the mouse to move the cursor to a proper location, and then click to confirm. 2) Click Measure in the menu bar, and select PA Rectangle, and you may perform rectangle measurement on the image. Or click the hotkey Measure Rectangle to finish rectangle measurement. 3) The measurement results are displayed in the "MeasureView." If the mouse is within the measuring range box, the current measurement result will be displayed automatically.
3-12
Operation of PA Files
Cross measure cursor
Fig. 3-12 B/[B]/C/D Scan image measurement example 3.3.4 MeasureView The measurement results of the image are displayed below the MeasureView, Click MeasureView to display the window and hide it. The left to the top of the window displays a thumbnail image of the measured image, and the right displays the specific measured data. According to the image type (AScan, BScan, [B] Scan CScan, DScan), the data display area is divided into different tabs, displaying measurement results of the images. See Fig. 3-13.
Fig. 3-13 Measure Result 3.3.4.1 Operation 1) Click DeleteAll, and all the measurement results (including AScan, BScan, [B] Scan,CScan, DScan images) will be cleared. 3-13
Operation of PA Files
2) Click DeleteChecked, and only the measurement results with the number before it being checked are cleared. 3) Click TxtExport to export the measurement results to a Txt file. 4) Check the box before LeftMeasImage or PopupMeasImage . When MeasureResult is selected, the left image area or the area above the measure window displays the thumbnail of the measured image automatically. If not checked, the thumbnail of the image area is not displayed but hidden. 5) Click the right mouse button in the "MeasureResult” window, and set up the items to be displayed in the "MeasureResult” window. Check √before the items to display with the left mouse button, or uncheck to cancel the display. 3.3.4.2 Description of measurement items Table 3-8 Measurement items of View A No. 1
2
3 4 5
6
7
Measurement Index
Group FrameIndex Gate
Amplitude(Peak)
SoundPath(Peak)
Depth(Peak)
8
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. B image frame number for the measurement result. Measurement for the gate. Amplitude percentage of echo measurement point in the gate (peak) Sound path of echo measurement point in the gate (peak) Depth of echo measurement point in the gate (peak) Horizontal distance of echo measurement
HorDistance(Peak)
point from probe (wedge) flank to Gate A (peak)
9
HdB(Peak)
dB difference between amplitude of echo 3-14
Operation of PA Files
No.
Measurement
Description measurement point and gate height in the gate (peak)
10
11
12
Amplitude(Flank)
SoundPath(Flank)
Depth(Flank)
13
Amplitude percentage of echo measurement point in the gate (flank) Sound path of echo measurement point in the gate (flank) Depth of echo measurement point in the gate (flank) Horizontal distance of echo measurement
HorDistance(Flank)
point from probe (wedge) flank to the gate (flank)
14
dB difference between amplitude of echo HdB(Flank)
measurement point and gate height in the gate (flank)
15
16
17
Amplitude(JFlank)
SoundPath(JFlank)
Depth(JFlank)
18
Amplitude percentage of echo measurement point in the gate (JFlank) Sound path of echo measurement point in the gate (JFlank) Depth of echo measurement point in the gate (JFlank) Horizontal distance of echo measurement
HorDistance(JFlank)
point from probe (wedge) flank to the gate (JFlank)
19
dB difference between amplitude of echo HdB(JFlank)
measurement point and gate height in the gate (JFlank)
Table 3-9 Measurement items of View B No. 1
2
Measurement Index
Group
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. 3-15
Operation of PA Files
No. 3
Measurement FrameIndex
4 LStart(MinusXValue)
Description B image frame number for the measurement result. The horizontal distance between the image at the cursor position and the probe center scale(minus XValue)
5 LStart 6 7 8
Length HStart: Height
The horizontal distance between the image at the cursor position and the probe center scale The horizontal distance of the images between 2 groups of cursor position. The image depth at the cursor position. The height between the images of 2 groups of cursor position.
Table 3-10 Measurement items of View C No. 1
2
Measurement Index
Group
3 LStart 4 5 6
Length WStart Width
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. The horizontal distance between the image at the cursor position and the probe center scale The horizontal distance of the images between 2 groups of cursor position. For C-scan only, indicating where the image at the cursor position is on the probe. For C-scan only, marking the image width between 2 groups of cursor positions.
Table 3-11 Measurement items of View D No. 1
2
3
Measurement Index
Group LStart
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. The horizontal distance between the image at the cursor position and the probe center 3-16
Operation of PA Files
No.
4 5 6
Measurement
Description
Length
scale The horizontal distance of the images between 2 groups of cursor position. The image depth at the cursor position.
HStart: Height
The height between the images of 2 groups of cursor position.
Table 3-12 Measurement items of View [B] No. 1
2
Measurement Index
Group
3 Line 4 LStart 5 6 7
Length HStart: Height
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. A Scan line number for the measurement result, valid only when the measurement object is A-scan image. The horizontal distance between the image at the cursor position and the probe center scale The horizontal distance of the images between 2 groups of cursor position. The image depth at the cursor position. The height between the images of 2 groups of cursor position.
3.4 Introduction of Corrosion Images 3.4.1 Open the File Start SuporUp. There are 2 ways to open a corrosion file. 1) Select File ->LoadCorrosionCScan from the menu. 3) Select "+ Corrosion” from the FileParameter window on the right. Find the directory storing SUPOR or SyncScan instrument corrosion files from the pop-up window, and then double click to open the corrosion scan file. The file opened is as shown in Fig. 3-14. 3-17
Operation of PA Files
★Tip:The corrosion scan results can be opened properly if they are placed in the same folder.
Fig. 3-14 Corrosion Scan Display The users may choose landscape or portrait view as per the operating practice. Click the hotkey Portrait or Landscape above the image. 3.4.2 Toolbar Features For the detailed menu features above the image, see Chapter 2. See Fig. 3-15 for the corrosion file toolbar.
Fig. 3-15 Corrosion scan toolbar 3-18
Operation of PA Files
3.4.2.1 Layout The users may set up the layout of corrosion files. Select from Layout. Put the mouse on the option, and the left will show the layout figure. See Fig. 3-16. The default layout is "A+B+C+D(1)".
Fig. 3-16 Layout menu To customize the layout, click LayoutSetting in the menu bar above the image, and it pops up Fig. 3-17. Finish the setting, and click OK.
3-19
Operation of PA Files
Fig. 3-17 Layout Setting To save the layout to the system, click Save Layout and input the name of the layout, the layout will appear in "Layout" menu on the right toolbar. The user can select the application. To delete the custom layout, use the right mouse button to click over the layout in the Layout menu, and click Delete button to delete it. The default layout option cannot be deleted. 3.4.2.2 Display Mode View D has 2 modes: SideView and RealShape. If the test part is a pipe, select RealShape for View D. See Fig. 3-18. 3-20
Operation of PA Files
【Note】:When the workpiece type is flat panel, and no "Display Mode" in the toolbar.
Real Shape
SideView
Fig. 3-18 View D 3.4.2.3 Display Item Set up the display items of View D as user required. There are 2 options: SideView and RealShape. See Fig. 3-19.
Fig. 3-19 Display Item 3.4.2.4 DigitalGain The description and setup are the same as 3.2.2. The image refreshes with the adjustment. When DataSource is Depth, adjusting DigitalGain will not regenerate a C/D image. 3.4.2.5 DataSource The description and setup are the same as 3.2.3. Change DataSource, and the image is regenerated.
3-21
Operation of PA Files
3.4.2.6 ImageProcess See the table below for image processing of view A, B, C and D. Table 3-13 Image processing function No.
Image Function
For images
Processing Zoom Reset: Reset the image to its default
1
image ratio
2 3 4 5 6
A, B, C, D
Gate Setting: To change the gate in view A.
A
Rebuild: To regenerate C/D images.
A, C, D
Color Scale: Reselect the color scale.
B, C, D
Layer Color: To set up image layer color.
C, D
Sectional Setup: To set up display range of View D.
D
★Tip:When DataSource is Amplitude, the Color Scale Setup function for C/D images is activated; When DataSource is Depth, the Layer Color Setup function for C/D images is activated 3.4.2.6.1 GateSetting The user can change GateLogic, GateStart, GateWidth, GateThresh, MeasPoint, MeasItem, MeasMode in GateSetting, in which MeasItem is for the measurement content displayed at the top right of View A, and other options are related to the generation of C/D images. SA is for measure point sound path of Gate A. SAB is for the value of |SA-SB|. Rebuild is to refresh C image. GateReset is to restore the gate-related information to system settings.
3-22
Operation of PA Files
Cancel is to cancel the setting and restore to the state before entering. Close is to close the current window without saving.
Fig. 3-20 Gate Setting 3.4.2.6.2 LayerColor ★Tip:When DataSource is set Depth, LayerColor setting is available for C and D images. If DataSource is set Amplitude, only ColorScale setting is available. The "LayerColor" window is divided into three areas: list and select area, adjust area and color preview area.
Fig. 3-21 LayerColor Setting 3-23
Operation of PA Files
Add: To add the setup layers to the "list and select area", with up to 8 layers can be set up. Modify: To select the layer to be modified from the list, and modify parameters for that layer in the adjust area. Delete: To select the layer color to be deleted. Click to delete the checked color layer. OK: To confirm the modification after color setup and preview. Close the window and refresh C image. Cancel: To cancel the modification and restore to the state before entering. Default: restore to the factory default settings. 3.4.2.6.3 Sectional Setting To perform sectional setting of View D, capture the start and end positions to be displayed. The user may drag the mouse over the workpiece simulation figure of View D to determine the start position and end position. The right of the arrow displays the current scale in real time. 3.4.2.7 Zoom Type According to the zoom type setup, the image is adjusted automatically to the display. Zoom type set up is not for image A and B, but for Image C and D. 【Note】: clicking the right mouse button on the view to display the menu.
Fig. 3-22 C image zoom type
3-24
Operation of PA Files
Fig. 3-23 D image zoom type FitAxesDir: The image is zoomed in axial direction. FitScanDir: The image is zoomed in encoder scan direction. FitDepth: The image is zoomed in depth direction. FitHorDir:The image is zoomed in horizontal direction. FitVerDir:The image is zoomed in vertical direction. FitSize:The image is zoomed in any type (without proportional restriction). System:Consistent with image generation. 3.4.2.8 Display Set up the display items for each view. For View D, the display can be set: SideView and RealShape. 【Note】: Click the right mouse button on the view to display the menu. 3.4.2.9 PositionSetting The coordinate of the image for View C can be adjusted for easy observation. Click the right mouse button on the image, and the setup screen is as shown in Fig. 3-24.
3-25
Operation of PA Files
Fig. 3-24 Position (Coordinate) Setting The coordinate for each file of View C can be adjusted. Select the subfile number to be adjusted from File, and the step for coordinate adjustment (HorStep, VerStep). Use the four directional buttons to change the coordinate start position. Long press it to change quickly. 3.4.3 Measure A-scan echo measurement: click Measure->AWaveEcho in the menu bar, select the gate and perform measurement. Or use the mouse to click the hotkey Gate A/B/C to finish gate measurement. Select A scan lines on B image. Use the mouse wheel to change the A scan line position, and the measure line positions on A and C images are updated accordingly.. C/D image measurement: Right click Measure in the menu bar, and select PA-Rectangle, and you may perform rectangle measurement on the CScan image. Or click the hotkey Measure Rectangle to finish rectangle measurement. 【Note】:Rectangle measurement for corrosive CScan files is available for CScan images only, but no measurement for AScan and BScan images. 3.4.3 MeasureResult The measurement results of the image are displayed below the MeasureView, the left of the window displays a thumbnail of the measured image (that can be hidden), and the 3-26
Operation of PA Files
right displays the specific measured data. See Fig. 3-25.
Fig. 3-25 Measure Result Window 3.4.3.1 Operation 1) Click DeleteAll, and all the measurement results (including AScan, BScan, [B] Scan,CScan, DScan images) will be cleared. 2) Click DeleteChecked, and only the measurement results with the number before it being checked are cleared. 3) Click TxtExport to export the measurement results to a Txt file. 4) Check the box before LeftMeasImage or PopupMeasImage . When MeasureResult is selected, the left image area or the area above the measure window displays the thumbnail of the measured image automatically. If not checked, the thumbnail of the image area is not displayed but hidden. 5) Click the right mouse button in the "MeasureResult” window, and set up the items to be displayed in the "MeasureResult” window. Check √before the items to display with the left mouse button, or uncheck to cancel the display. 3.4.3.2 Description of measurement items See Table 3-14 for the description of measurement items
3-27
Operation of PA Files
Table 3-14 Description of measurement items No. 1
2
3
Measurement Index
FileIndex FrameIndex
4 LineIndex 5 6
7
Gate
Amplitude
Depth
8
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. B image frame number for the measurement result. A Scan line number for the measurement result, valid only when the measurement object is A-scan image. Measurement for the gate. Amplitude percentage of echo measurement point in the gate (peak) Depth of echo measurement point in the gate (peak) Horizontal distance of echo measurement
HorDistance
point from probe (wedge) flank to Gate A (peak)
9
SoundPath
10
Sound path of echo measurement point in the gate The horizontal distance between the image
LStart
at the cursor position and the probe center scale
11
12
13
14
15
Length
WStart
Width
Area
MinDepth
The horizontal distance of the images between 2 groups of cursor position. For C-scan only, indicating where the image at the cursor position is on the probe. For C-scan only, marking the image width between 2 groups of cursor positions. For C-scan only, marking the image area between 2 groups of cursor positions. For C-scan only, the minimum depth in the measure range. 3-28
Operation of PA Files
No. 16
17 18
Measurement MaxDepth HStart Height
19
Description For C-scan only, the maximum depth in the measure range. The image depth at the cursor position. The height between the images of 2 groups of cursor position. For D-scan only, convert the measure
StartAngle
range(cursor position) to an angle and display it.
20
EndAngle
For D-scan only, convert the measure range (cursor position) to an angle and display it.
3-29
Operation of TOFD Files
Chapter 4 Operation of TOFD Files 4.1 Open and Close Files 4.1.1 Open A File Start SuporUp. There are 3 ways to open a file. 1) Select File -> Open from the menu. 2) Press the hotkey Open, 3) Select + File from the FileParameter window on the right. Find the directory storing SUPOR or SyncScan instrument files from the pop-up window, and then double click the TOFD record file (*.trec) or parameter file (*.tdat) to open it. See Fig. 4-1. The parameter file includes A-scan echo images only, which is for file parameter setup in scan review, and simple A-scan image functions. ★Tip: The user can open multiple TOFD files in the software at the same time.
4-1
Operation of TOFD Files
Fig. 4-1 Open TOFD Image 4.1.2 Close A File There are 3 ways to close a file. 1) Select File -> Close, and select the desired file name to close the file. 2) Click the hotkey Close to close the file directly. 3) Select - All or Checked from the file parameter window to close it. 【Note】:Select "- All" to close all files; Select “-Checked” to close the selected file only, after using the mouse to click the file to be closed.
4.2 Change Imaging Direction Click the hotkey Direction-Portrait or Direction-Landscape in the menu bar above the image to change the imaging direction of TOFD images.
4.3 LW Reference Line Setup Use the mouse to click the measure line with LW, and the LW reference line (in a dotted ine) is selected. Move the mouse cursor to the position where the lateral wave is to be set, click 4-2
Operation of TOFD Files
the left mouse button to confirm and finish the LW reference line setup. See Fig. 4-2, Use the menu ColorAndLine to set up the line size and color. 【Note】:After selecting the "LW" reference line, use the keyboard direction buttons to fine tune the reference line position.
Fig. 4- 2 LW reference line setup
4.4 Color Scale Setup Double click the color scale on the right of the image, as shown in Fig. 4-2, to bring up the color scale window. The user can set up the proper color scale for display.
4.5 Toolbar Features The menu bar above the image is general menu settings for all files. See Chapter 2 for details. See the figure below for the toolbar of TOFD files.
4-3
Operation of TOFD Files
Fig. 4-3 TOFD file toolbar 4.5.1 Play
1) Click the play button
2) Click the stop button
to play back images automatically.
or
to pause or stop playing.
3) Adjust the playback speed by using the fast-forward button
or rewind button
, and the playback speed will be updated simultaneously.
4) When in stop state place the mouse at the play slider
, hold the left button and
slide, and images are played at the slide speed. Release the button to stop playback. See Fig. 4-4.
Fig. 4-4 Play Adjustment 4.5.2 DigitalGain The image gain range is -20.0dB~20.0dB, with the step 0.5dB. Use the menu DigitalGain to make adjustment. See Fig. 4-5.
4-4
Operation of TOFD Files
Fig. 4-5 Gain Adjustment 4.5.3 ImageProcess No processing is available for view A of TOFD images, with the menu ImageProcess disabled. 4.5.3.1 Straightening Straightening is used to do image processing on TOFD image lateral wave or bottom wave area, so that part of the TOFD image will have alignment based on the lateral wave or bottom wave of one scan line. Here is the specific operation: (1) Click Toolbar -> ImageProcess -> Straightening (2) Click the left mouse button in the TOFD image area to confirm straightening the reference scan line. (3) Move the mouse to the desired start for straightening and click, then move the mouse to the end for straightening and click again. The system automatically performs straightening. (4) To cancel straightening, press Recover to remove the straightening operation. 4.5.3.2 Filter Filter is to do image processing on the lateral wave or bottom wave on the TOFD image and filter the lateral wave or bottom wave of partial TOFD image. Here is the specific operation: (1) Click Toolbar -> ImageProcess -> Filter . (2) Click the left mouse button in the TOFD image area to confirm filtering the reference 4-5
Operation of TOFD Files
scan line; (3) Move the mouse to the desired start for filter and click, then move the mouse to the end for filter and click again. The system automatically performs filter. (4) To cancel filter, press Recover to remove the filter operation. 4.5.3.3 SAFT SAFT(Synthetic Aperture Focusing Technique), for post processing of TOFD images, is to bring images more accurate and closer to the real situation. Click SAFT button on ImageProcess, and the system automatically performs SAFT processing. 【 Note 】 :SAFT processing is not available after the image is processed by Straightening or Filter. 4.5.3.4 Recover After image processing such as Straighten, Filter and SAFT, press Recover to restore the image to its original state. 4.5.3.5 ZoomRestore 【Note】:The image can be enlarged in two ways. The ZoomRestore button applies to local zoom-in and local zoom-out only. 1) Full-screen zoom: You can zoom in the view to the full image display window. Double left click the mouse button on the title bar of the view window, then the entire window of the image will be enlarged to the maximum. Double-click the title bar again to restore it to the original size. 2) Local zoom: Select the zoom area start from the TOFD image. Hold down the left mouse button and drag to the lower right. Now a rectangular frame indicating the selected area appears. Release the left mouse button, and the rectangular area is enlarged to to full screen. To zoom out to the original image size, click ImageProcess -> ZoomRestore. On the enlarged image, hold down the left mouse button and drag to the upper left. Now a rectangular frame indicating the selected area appears. Release the left mouse button, 4-6
Operation of TOFD Files
and the rectangular area is zoomed out. 4.5.4 Contrast Click Toolbar -> Contrast above the TOFD image. Select the contrast from the drop-down menu. The contrast ranges 20%~100%. For multi-channel images, you may change the contrast of each image. 4.5.5 ArcLength Click Toolbar -> ArcLength above the TOFD image. Select the length of the reference arc from the drop-down menu. The arc length ranges from 1 to 100. 4.5.6 Display The Display menu lists the items selectable for display for each view. The use may check the menu items to be displayed as required by review and measurement. 【Note】: To display this menu, click the right mouse button on the view. 4.5.6.1 Measure Line (1) Adjust the horizontal or vertical measure line individually. Left click on the horizontal or vertical measuring line to activate it (displayed in a dotted line). Move the mouse to the measure position and click the left mouse button again. Now the horizontal or vertical measure line adjustment is finished. (2) Adjust the horizontal or vertical measure line at the same time. Click the intersection of the horizontal and vertical measure lines to activate them (displayed in dotted lines). Move the mouse to the measure position and click the left mouse button again. Now the horizontal and vertical measure line adjustment is finished. 4.5.6.2 Echo Amplitude Line On an A-Scan image, the "echo amplitude line" indicates the echo amplitude peak. The "echo amplitude line" changes with the waveform of the measure line, which cannot be adjusted manually.
4-7
Operation of TOFD Files
4.6 TOFD Image Measurement 4.6.1 Measurement Operation Select Measure -> TOFD Rectangle, or click MeasureRectangle in the shortcut menu to perform rectangular measurement of TOFD images. After the rectangular measurement is finished, the measure results are automatically displayed in the MeasureResult window. 【NOTE】: No measurement of A-Scan images for TOFD files. 4.6.2 MeasureResult The image measure result is displayed in the MeasureResult window below SuporUp screen. Click MeasureResult to display and then hide the window. A thumbnail of the measured image is displayed on the left or above the window. The right side displays the data of measurement. According to the image type (A Scan or TOFD), the data display areas are divided into different tabs, displaying measure results of each image. See Fig. 4-6.
Fig. 4- 6 Measure Result Window 4.6.2.1 Operation (1) Click DeleteAll, and all the measurement results will be cleared. (2) Click DeleteChecked, and only the measurement results with the number before it being checked are cleared. (3) Click TxtExport to export the measurement results to a Txt file. 4-8
Operation of TOFD Files
(4) Check the box before LeftMeasImage or PopupMeasImage, and the left image area or the area above the measure window displays the thumbnail of the measured image automatically. If not checked, the thumbnail of the image area is not displayed but hidden. (5) Click the right mouse button in the MeasureResult window, and set up the items to be displayed in the "MeasureResult” window. Check √ before the items to display with the left mouse button, or uncheck to cancel the display. 4.6.2.2 Description of measurement items See the description of Measurement items in Table 4-1. Table 4-1 Description of Measurement items No.
Measurement
1
Index
2
Channel
3
LStart
4
Length
5
HStart
6
Height
Description Arranged to the order of image measurement operation. The channel number if TOFD scan is valid. The horizontal distance from the image at the cursor position to the probe central scale. The distance of the measured image between 2 groups of cursor position. The depth from the image at the cursor position to the work piece surface. The height between the images of 2 cursor positions.
4-9
Operation of Conventional UT Files
Chapter 5 Operation of Conventional UT Files 5.1 Open and Close Files 5.1.1 Open A File Start SuporUp. There are 3 ways to open a file. (1) Select File -> Open from the menu. (2) Press the hotkey Open, (3) Select + File from the FileParameter window on the right. Find the directory storing SUPOR or SyncScan instrument files from the pop-up window, and then double click the conventional UT record file (*.urec) or parameter file (*.udat) to open it. See Fig. 5-1. ★Tip: The user can open multiple UT files in the software at the same time. The SUPOR instrument supports opening parameter files only.
Fig. 5-1 Open UT Image 5-1
Operation of Conventional UT Files
5.1.2 Close A File There are 3 ways to close a file. (1) Select File -> Close, and select the desired file name to close the file. (2) Click the hotkey Close to close the file directly. (3) Select - All or Checked from the file parameter window to close it. 【Note】: Select "- All" to close all files; Select “-Checked” to close the selected file only, after using the mouse to click the file to be closed.
5.2 Image Layout Subject to the user operation habit, the image layout can be set as Landscape or Portrait . Click the hotkey Landscape or Portrait to set up. See the figures in Fig. 5-2 and Fig. 5-3.
Fig. 5-2 Landscape View
5-2
Operation of Conventional UT Files
Fig. 5-3 Portrait View
5.3 Zoom Image Zoom Image may zoom the view to the whole image display window. Double left click the mouse button on the title bar of the view window, while the other images are automatically hidden. Then double left click the title bar again to restore it to the original size.
5.4 Color Scale Selection Double click the color scale on the right of the image to bring up the set color scale window. The user can set up the proper color scale for display.
5.5 Toolbar Features The menu bar above the image is general menu settings for all files. See Chapter 2 for details. See Fig. 5-4 for the toolbar of UT files.
Fig. 5-4 UT file toolbar
5-3
Operation of Conventional UT Files
5.5.1 Play
1)
Click the play button
2)
Click the stop button
3)
Adjust the playback speed by using the fast-forward button button
4)
to play back images automatically. or
to stop playing. or rewind
, and the playback speed will be updated simultaneously.
When in stop state place the mouse at the play slider
, hold the left button
slide, and images are played at the slide speed. Release the button to stop playback. See Fig. 5-5. The play slider start position is for the scan start position of the image. 【Note】: If the scan type is a cine or time based, the unit below the play slider is a time unit (00:00); if the scan type is encoder, the unit below the play slider is a length unit (mm).
Fig. 5-5 Play Adjustment 5.5.2 Display The menu items for different views are not the same. The user may check the menu items to be displayed as required. 【Note】: Click the right mouse button on the view to display the menu. 5.5.2.1 View A See Table 5-1 for the menu items displayed in View A. 5-4
Operation of Conventional UT Files
Table 5-1 Menu items displayed in View A No.
Item
Description
1
Gate A/B/C
Display gate A/B/C at the top right of the view window.
2
EchoSoundPath
Echo sound path measurement in the gate displayed at the top right of the view window.
3
EchoDepth
Echo depth measurement in the gate displayed at the top right of the view window.
4
EchoHorDistance
Echo horizontal distance measurement in the gate displayed at the top right of the view window.
5
EchoAmplitude
Echo amplitude measurement in the gate displayed at the top right of the view window.
6
HdB
HdB measurement in the gate displayed at the top right of the view window.
7
ERS
In AVG curve state, the flat-bottomed hole (FBH) equivalence of measure point echoes in the gate.
8
Peak
Set the gate measurement mode to “Peak" in the view window.
9
Flank
Set the gate measurement mode to “Flank" in the view window.
10
JFlank
Set the gate measurement mode to “JFlank" in the view window.
11
Sec.Color
If enabled, the secondary wave area is marked out.
12
WaveFill
For turning on/ off WaveFill function.
13
DAC/AVG
For selecting to display the curve on the A-Scan image if DAC or AVG curve is available for system scanning.
5.5.2.2 View B See Table 5-2 for the menu items displayed in View B. Table 5-2 Menu items displayed in View B No. 1
Item
Description
MeasureLine
Display/close the measure line.
5-5
Operation of Conventional UT Files
5.5.3 Sync If the data is multi-channel data, MeasureLine is selectable in the Sync menu. After enabling the sync measure line, when moving the measuring line of one channel, the measure lines for other channel are moved synchronously.
5.6 Image Measurement 5.6.1 AScan image measurement 5.6.1.1 Measure menu After selecting AScan image window, right click the tab UT AWaveEcho in the MeasureResult window, and select the measure items from the pop-up window. 5.6.1.2 Measurement Operation Up to three measurement gates can be displayed at the same time in the A-Scan image window. (1) Gate width adjustment. Place the cursor on any side of the gate. Left click when the cursor changes to a double arrow, and the gate is being selected (dotted line). Move the mouse to adjust the gate size, and left click to confirm. (2) Gate position adjustment. Place the cursor in the middle of the gate, left click when the cursor changes to a four-way cross cursor, and the gate is being selected (dotted line). Move the mouse to adjust the gate position, and left click to confirm. After the gate adjustment is finished, select Measure -> AWave Echo for the gate, and you may perform measurement for the gate; or click the gate measurement icon Gate in the shortcut menu bar to finish measurement quickly. Now the number (1, 2, ......) displayed at the gate refers to the number of measurement. The measurement result is displayed on the right of the AScan image, with the font color corresponding to the gate line color. See Fig. 5-6.
5-6
Operation of Conventional UT Files
Measurement result
Number of measurement
Fig. 5-6
Gate measurement example of A-Scan image
5.6.2 BScan Image Measurement Rectangle measurement is available for BSan images. Press the hotkey Measure Rectangle to perform measurement, with the measurement results displayed in MeasureResult. 5.6.3 MeasureResult 5.6.3.1 Operaiton The measurement results are displayed below the MeasureResult window, the left of the window displays a thumbnail image of the measured image, and the right displays the specific measured data. See Fig. 5-7. (1) Click DeleteAll, and all the measurement results (including UT AScan and UT BScan images) will be cleared. (2) click DeleteChecked, and only the measurement results with the number before it being checked are cleared. (3) Click TxtExport to export the measurement results to a Txt file. (4) Check the box before LeftMeasImage or PopupMeasImage . When MeasureResult is selected, the left image area or the area above the measure window displays the thumbnail of the measured image automatically. If not checked, the thumbnail of the 5-7
Operation of Conventional UT Files
image area is not displayed but hidden. (5) Click the right mouse button in the "MeasureResult” window, and set up the items to be displayed in the "MeasureResult” window. Check √ before the items to display with the left mouse button, or uncheck to cancel the display.
Fig. 5-7 Measure Result 5.6.3.2 Description of measurement items Table 5-3 Measurement items of View UT A No. 1 2 3 4 5 6 7 8 9
Measurement Index Group FrameIndex Gate
Amplitude SoundPath Depth HorDistance HdB
Description To arrange in the operation order of image measurement. Group number, valid only when in PA group scanning. B image frame number for the measurement result. Measurement for the gate. Amplitude percentage of echo measurement point in the gate Sound path of echo measurement point in the gate Depth of echo measurement point in the gate Horizontal distance of echo measurement point from probe (wedge) flank to Gate A dB difference between amplitude of echo 5-8
Operation of Conventional UT Files
No.
Measurement
Description measurement point and gate height in the gate
10
ERS
In AVG curve state, the flat-bottomed hole (FBH) equivalence of measure point echoes in the gate.
Table 5-4 Measurement items of View UT B No.
Measurement
1
Index
2
Channel
3
LStart
4
Length
5
HStart
6
Height
Description Arranged to the order of image measurement operation. The channel number. The horizontal distance from the image at the cursor position to the probe central scale. The distance of the measured image between 2 groups of cursor position. The depth from the image at the cursor position to the work piece surface. The height between the images of 2 cursor positions.
5.7 Record and Play Conventional UT Cine The Conventional UT cine files saved in the instrument can be played on SuporUp software, which is for review and playback, but not for measurement. During the playback, the parameter information in the file parameters are updated synchronously, and the adjusted parameters are marked out with a yellow background. (1) Click the play button
in Toolbar -> Play, and images are cycle played back
automatically. (2) Click the stop button
or
to pause or stop playing.
(3) Adjust the playback speed by using the fast-forward button
5-9
or rewind button
Operation of Conventional UT Files
,
with multiple steps available. To view the last frame directly, click
the first frame click
, to view
.
(4) When in stop state place the mouse at the play slider
, hold the left button and
slide, and images are played at the slide speed. Release the button to stop playback. See Fig. 5-9.
Fig. 5-9 Play Cine
5-10
Operation of TG Files
Chapter 6 Operation of TG Files 6.1 Open and Close Files 6.1.1 Open A File Start SuporUp. There are 3 ways to open a file. (1) Select File -> Open from the menu. (2) Press the hotkey Open, (3) Select + File from the FileParameter window on the right. Find the directory storing SUPOR or SyncScan instrument files from the pop-up window, and then double click the TG (thickness gauge) data set (*.tgdat) or parameter file (*.tgpar) to open it. See Fig. 6-1. ★Tip: The TG data set files may show the measured thickness values (as shown below), and the parameter files include waveform image areas only.
TG Reading
Image Area
Fig. 6-1 Open TG Image 6-1
Operation of TG Files
6.1.2 Close A File There are 3 ways to close a file. (1) Select File -> Close, and select the desired file name to close the file. (2) Click the hotkey Close to close the file directly. (3) Select - All or Checked from the file parameter window to close it. 【Note】: Select "- All" to close all files; Select “-Checked” to close the selected file only, after using the mouse to click the file to be closed.
6.2 ColorAndLine Setup For TG data set files, the colors of thickness and alarms can be set up in the menu ColorAndLine. Up to 8 group settings can be set up. See Fig. 6-2.
Fig. 6-2 Color Setup for Layers
Add: To add a new color for the setup thickness.
Modify: To select the thickness to be modified from the list, and modify 6-2
Operation of TG Files
parameters of the thickness in the adjust fields.
Delete: Select the thickness color to be deleted. Click Delete to delete the selected thickness color.
Apply: To confirm the modification after color setup and preview.
Default: To restore to the factory default settings.
Quit: To quit the modification and restore to the state before entering.
After setting, the background color of the thickness reading area changes, and the reading at the upper right corner of the image area changes accordingly.
6.3 Thickness Reading Area Click any reading with the mouse. The title bar above will display the information of the current position, and the left waveform will display the image of information of the current position.
Fig. 6-3 Thickness Reading Area Right-click the reading area to bring up the menu as shown in Fig. 6-4.
Fig. 6-4 Menu of Reading Area 6-3
Operation of TG Files
6.3.1 Display Mode Subject to user habit, the display mode of reading can be selected from a list or table. 6.3.2 Search Enter the search condition in the search field, and the readings complying with the search condition are listed in a table, and it prompts the total number that meets the condition.
Fig. 6-5 Reading Search 6.3.3 Export Excel File This function is to export the entire list/ table of readings to an Excel file. The display mode when exported is the display mode (list or table) of the current reading area. After export, the Excel will be automatically opened for review.
6-4
Test Report
Chapter 7 Test Report Users may import file information and measurement results to reports, which can be generated automatically. Before import, please edit and manage the report templates and user information for recall in subsequent use. See Fig. 7-1 for the report menu.
Fig. 7-1 Report Menu
7.1 Template Manager The user may edit and set up the report template when generating a report. The edited templates will be automatically saved in the list, and you may open it directly upon next use.
7-1
Test Report
Fig. 7-2 Template Manager 7.1.1 Type Selection How to set up Data Type and Template Type. Data Type includes: PA, TOFD, UT and TG, subject to system mode. Usually the system will automatically select the data type according to the file opened. Template Type includes: Word and Excel. The default template type is Word, and the user can customize it to Excel. 7.1.2 New Template Import: Based on the selected data type and template type, the selected template path and related information are imported to the list. The user can choose a template to import for use. New Empty: Create a new blank Word / Excel report file. New Sel: Make changes on the selected template, and create a new Word / Excel 7-2
Test Report
report file. Remove Sel: Remove the selected template from the list. But the default template shall not be removed. Clear List: Clear all the templates in the list except for the default template. Remark: According to the selected data type, the remark list is popped up for user review. All the remark key words may be copied. See Fig. 7-3. ¾ Input the filter condition in the field "Data Filter", and the entries meeting the condition are filtered out in the list. ¾ Click on the title bar, and the entries can be rearranged by Index, Name or Bookmark. ¾ In the list, the line in blue background is level 1 menu, the line in gray background is level 2 menu, and the line without background color is level 3 menu. For keywords of PA and corrosion scan files, see Appendix A; For keywords of TOFD files, see Appendix B; For keywords of UT files, see Appendix C; For keywords of TG files, see Appendix D.
7-3
Test Report
Fig. 7-3 Remark View 7.1.3 Template List To list all the templates imported to the software for direct use or edit.
7.2 UserInfoManage Some basic user information in the reports can be edited to a template for direct reference when generating reports, without re-entering such information. For the user information management screen, see Fig. 7-4. The left side is a list of saved user information, the middle includes the details of selected or edited information, and the right side contains action buttons. 1)
New. Click New button to create new user information.
2)
Edit. Select an entry of user information from the information save list on the left, click Edit to edit or delete the file name, item and value for that entry.
Operation: Click the keyword or value in the information details to bring up the options available. Click × button in the optional list to remove the option from the list. In the last column input the 7-4
Test Report
item and click + button to add an item. Saving the custom added items will automatically generate the bookmarks, which can be viewed in "bookmark preview". The user needs to input in the "Value" column, and the entered info will be saved as a drop-down menu for the same item, which can be selected from the drop-down menu by another user when editing information. 【Note】: The new bookmark rule is "RIV_Ext_keyword". Since the bookmark supports letters, numbers and underlines only, other characters in the keyword are substituted by underlines.
Fig. 7-4 User Info Manager
7.3 Generate Report Click the menu bar Report -> Generate Report, and the system pops up the report content edit screen. See Fig. 7-5. Template column lists the saved report templates matching the current file type. The users 7-5
Test Report
can use directly or click Temp Man to quickly access the template edit screen. UserInfo column lists all saved user information items. The users can use directly or click Info Man to quickly access the user information edit screen. If any information in the list of "Value" in UserInfo is changed, press Save to save the information. ★ Tip: For more information about template edit, see 7.1 Template Manager. For more information about user information edit, see 7.2 UserInfoManage. After selecting the template and user information, press Report to generate a report, and open the report file for review. If no report is generated, press Quit to exit the Test Report screen.
Fig. 7-5 Generate Test Report
7.4 Report Now Click the menu bar Report -> Report Now, and the software generates a report based on the last template in use and the user information, and open report file for review.
7-6
Software Maintenance
Chapter 8 Software Maintenance 8.1 Software Upgrade SuporUp computer data processing software is a post-processing tool for industrial ultrasound testing systems. With the development of industrial ultrasonic equipment, computer and network technology, new products will be released as the software keeps updating and improving.
8.2 Telephone or E-mail Enquiry To learn more about the company technology, products and service, or if an exception is found in product use, please contact SIUI service.
8.3 SIUI Service Contact Information Shantou Institute of Ultrasonic Instruments Co., Ltd. (SIUI) Add: 77 Jinsha Road, Shantou, Guangdong 515041, China Tel: 86-754-88250150 Fax: 86-754-88251499 Website: http://www.siui.com E-mail:
[email protected]
8-1
Keywords for General Info in Reports
Appendix A Keywords for General Info in Report Item
UserInfo RIV_Ext_Param
FileInfo RIV_File_Param
MachineInfo RIV_Machine_Param
Name
Keyword
Entrustment Company
RIV_Ext_Entrustment_Company
Inspection Company
RIV_Ext_Inspection_Company
Supervision Company
RIV_Ext_Supervision_Company
Standard
RIV_Ext_Standard
Workpiece Type
RIV_Ext_Workpiece_Type
Groove_Type
RIV_Ext_Groove_Type
Specs
RIV_Ext_Specs
Material
RIV_Ext_Material
Surface
RIV_Ext_Surface
Thickness
RIV_Ext_Thickness
Method
RIV_Ext_Method
Date
RIV_Ext_Date
Coupling
RIV_Ext_Coupling
FileName
RIV_FileName
FileType
RIV_FileType
FileNum
RIV_FileNum
GroupNum/ ChannelNum
RIV_TotalChannelNum
Remark
RIV_Remark
Machine
RIV_Machine
MachineSN
RIV_MachineSN
Module
RIV_Module
ModuleSN
RIV_ModuleSN
SoftwareVersion
RIV_SoftwareVersion
HardwareVersion
RIV_HardwareVersion
BaseTimeScanInfo
ScanInfo RIV_Encoder_Param
SingleAxisInfo
DoubleAxisInfo
A-1
FrameNum
RIV_FrameNum
ScanMode
RIV_ScanMode
ScanTimeStep
RIV_ScanTimeStep
ScanLength
RIV_ScanLength
FrameNum
RIV_FrameNum
EncoderName
RIV_EncoderName
ScanMode
RIV_ScanMode
ScanEncoderStep
RIV_ScanEncoderStep
EncoderXMpp
RIV_ScanEncoderXMpp
ScanLength
RIV_ScanLength
FrameNum
RIV_FrameNum
EncoderName
RIV_EncoderName
Keywords for General Info in Reports
Item
Name
Keyword
DoubleAxisInfo
ScanInfo RIV_Encoder_Param
UTCineScanInfo
Flat-NoneWorkpiec eInfo
WorkpieceInfo RIV_Workpiece_Param
Flat-SimpleWorkpie ceInfo
Flat-VWorkpieceInfo
A-2
ScanMode
RIV_ScanMode
EncoderStepX
RIV_ScanEncoderStepX
EncoderXMpp
RIV_ScanEncoderXMpp
EncoderStepY
RIV_ScanEncoderStepY
EncoderYMpp
RIV_ScanEncoderYMpp
ScanLength
RIV_ScanLength
FrameNum
RIV_FrameNum
ScanMode
RIV_ScanMode
StartTime
RIV_ScanStartTime
EndTime
RIV_ScanEndTime
ScanTimeStep
RIV_ScanTimeStep
ScanLength
RIV_ScanLength
FrameIndex
RIV_ScanFrameIndex
FrameTime
RIV_ScanFrameTime
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
Thickness
RIV_Thickness
GrooveType
RIV_GrooveType
GroovePosition
RIV_GroovePosition
GrooveWidth
RIV_GrooveWidth
RootWidth
RIV_RootWidth
ShoulderHeight
RIV_ShoulderHeight
HeatAffactZone
RIV_HeatAffactZone
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
Keywords for General Info in Reports
Item
Name
Keyword
Flat-VWorkpieceInfo
Flat-DVWorkpieceIn fo
WorkpieceInfo
GrooveWidth
RIV_GrooveWidth
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GroovePosition
RIV_GroovePosition
GrooveWidth
RIV_GrooveWidth
Distance P
RIV_DistP
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
RIV_Workpiece_Param
HeatAffactZone
RIV_HeatAffactZone
(Continued)
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GrooveWidth
RIV_GrooveWidth
Distance P
RIV_DistP
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
Flat-YWorkpieceInfo
Flat-XWorkpieceInfo
A-3
Keywords for General Info in Reports
Item
Name
Keyword
WorkpieceInfo RIV_Workpiece_Param
GrooveWidth
RIV_GrooveWidth
Distance P
RIV_DistP
(Continued)
RootPos
RIV_RootPos
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GrooveWidth
RIV_GrooveWidth
Radius
RIV_RootRadius
Distance P
RIV_DistP
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
PadThk
RIV_PadThk
PadLen
RIV_PadLen
GrooveWidth
RIV_GrooveWidth
Distance P
RIV_DistP
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness
RIV_Thickness
Flat-XWorkpieceInfo
Flat-UWorkpieceInf o
Flat-DYWorkpieceIn fo
Flat-IWorkpieceInfo
A-4
Keywords for General Info in Reports
Item
Name
Keyword MaterialType
RIV_MaterialType
RIV_Workpiece_Param
LongitudinalVel
RIV_LongitudinalVel
(Continued)
ShearVel
RIV_ShearVel
Clearance
RIV_Clearance
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
Thickness1
RIV_Thickness1
Thickness2
RIV_Thickness2
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GrooveWidth
RIV_GrooveWidth
Distance L
RIV_DistL
LPos
RIV_LPos
Clearance
RIV_ClearanceRoot
Distance P
RIV_DistP
RootPos
RIV_RootPos
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
FlangeThk
RIV_FlangeThk
WebThk
RIV_WebThk
CrossAng
RIV_CrossAng
Clearance
RIV_Clearance
LeftAng
RIV_LeftAng
RightAng
RIV_RightAng
LeftH
RIV_LeftH
RightH
RIV_RightH
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
PipeDiameter
RIV_PipeDiameter
WorkpieceInfo
Flat-IWorkpieceInfo
Flat-DiffThkWorkpie ceInfo
AngleWorkpieceInfo
PipeWorkpieceInfo
A-5
Keywords for General Info in Reports
Item WorkpieceInfo RIV_Workpiece_Param
Name
Keyword
PipeWorkpieceInfo
(Continued)
SmallPipe-VWorkpi eceInfo
SmallPipe-YWorkpi eceInfo
A-6
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
PipeDiameter
RIV_PipeDiameter
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GrooveWidth
RIV_GrooveWidth
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
WorkpieceName
RIV_WorkpieceName
WorkpieceType
RIV_WorkpieceType
GrooveType
RIV_GrooveType
PipeDiameter
RIV_PipeDiameter
Thickness
RIV_Thickness
MaterialType
RIV_MaterialType
LongitudinalVel
RIV_LongitudinalVel
ShearVel
RIV_ShearVel
GrooveWidth
RIV_GrooveWidth
Distance P
RIV_DistP
Clearance
RIV_ClearanceRoot
Reinforcement
RIV_Reinforcement
RootReinforcement
RIV_RootReinforcement
Distance M
RIV_DistM
HeatAffactZone
RIV_HeatAffactZone
Keywords for Phased Array and Corrosion Report
Appendix B Keywords for Phased Array and Corrosion Report In the table below, X in description such as RIV_X_ProbeName refers to channel phased-array group index, X=1 for group 1, and so on. Item
Name
GroupInfo
RIV_PA_Groups_Param
ProbeInfo RIV_PA_X_Probe_Param
WedgeInfo RIV_PA_X_Layer_Param
SettingInfo RIV_PA_X_Scan_Param
Keyword
ProbeName
RIV_X_ProbeName
ProbeType
RIV_X_ProbeType
ProbeFreq
RIV_X_ProbeFreq
ElementNum(n)
RIV_X_ProbeElementNum
Pitch(p)
RIV_X_ProbePitch
CrustL
RIV_X_ProbeL
CrustW
RIV_X_ProbeW
CrustH
RIV_X_ProbeH
WedgeName
RIV_X_LayerName
WedgeType
RIV_X_LayerType
WedgeAngle
RIV_X_LayerAngle
RefractionAngle
RIV_X_RefractionAngle
WedgeVel
RIV_X_LayerVel
First Element XT(XT)
RIV_X_LayerXT
First Element X(X)
RIV_X_LayerX
First Element Height(Z)
RIV_X_LayerZ
WedgeLength(L)
RIV_X_LayerL
WedgeWidth(W)
RIV_X_LayerW
WedgeHeight(H)
RIV_X_LayerH
WedgeRadius(R)
RIV_X_LayerR
Calibration
RIV_X_Calibration
LineNum
RIV_X_LineNum
ProbePosition
RIV_X_ProbePosition
DistanceE
RIV_X_DistanceE
ScanDepth
RIV_X_ScanDepth
DispDelay
RIV_X_DispDelay
PulseFreq
RIV_X_PulseFreq
ReceiveFreq
RIV_X_ReceiveFreq
PulseVoltage
RIV_X_PulseVoltage
PRF
RIV_X_PulsePRF
PulsePower
RIV_X_PulsePower
Gain
RIV_X_Gain
EchoType
RIV_X_EchoType
MaterialVel
RIV_X_MaterialVel
B-1
Keywords for Phased Array and Corrosion Report
Item
SettingInfo RIV_PA_X_Scan_Param (Continued)
Sample Setting RIV_PA_X_Gate_Param
LayerColor RIV_LayerColor_Param
Area Simulation RIV_AreaSimul_Param
Name
Keyword
HorizontalZero
RIV_X_HorizontalZero
ScanType
RIV_X_ScanType
ScanStartElement
RIV_X_ScanStartElement
ScanEndElement
RIV_X_ScanEndElement
ScanLinearStep
RIV_X_ScanLinearStep
ScanAperture
RIV_X_ScanAperture
ScanStartAngle
RIV_X_ScanStartAngle
EndAngle
RIV_X_ScanEndAngle
AngleStep
RIV_X_ScanAngleStep
ScanAngle
RIV_X_ScanAngle
ScanFocus
RIV_X_ScanFocus
BeaSw
RIV_X_BeaSw
BeaCompensate
RIV_X_BeaCompensate
BeaStart
RIV_X_BeaStart
BeaEnd
RIV_X_BeaEnd
GateALogic
RIV_X_GateALogic
GateAStart
RIV_X_GateAStart
GateAWidth
RIV_X_GateAWidth
GateAThresh
RIV_X_GateAThresh
GateAMeasPoint
RIV_X_GateAMeasPoint
GateBLogic
RIV_X_GateBLogic
GateBStart
RIV_X_GateBStart
GateBWidth
RIV_X_GateBWidth
GateBThresh
RIV_X_GateBThresh
GateBMeasPoint
RIV_X_GateBMeasPoint
GateCLogic
RIV_X_GateCLogic
GateCStart
RIV_X_GateCStart
GateCWidth
RIV_X_GateCWidth
GateCThresh
RIV_X_GateCThresh
GateCMeasPoint
RIV_X_GateCMeasPoint
ThicknessGroup
RIV_X_ThicknessGroup
Color_N
RIV_X_Color_N
StartColor_N
RIV_X_StartColor_N
EndColor_N
RIV_X_EndColor_N
StartThickness_N
RIV_X_StartThickness_N
EndThickness_N
RIV_X_EndThickness_N
ThicknessStep_N
RIV_X_ThicknessStep_N
OverMaxColor
RIV_X_OverMaxColor
OverMinColor
RIV_X_OverMinColor
ErrorColor
RIV_X_ErrorColor
AxaesStep
RIV_X_AxisYStep
B-2
Keywords for Phased Array and Corrosion Report
Item Area Simulation RIV_AreaSimul_Param (Continued)
Measure Result RIV_MeasResult
Image RIV_Picture
Name
Keyword
ApertureLength
RIV_X_ApertureLen
CoverPorPortion
RIV_X_CoverPorPortion
StartPos
RIV_X_StartPos
EndPos
RIV_X_EndPos
AxisYPosition_N
RIV_X_AxisYPosition_N
AWaveEcho
RIV_PA_AMeasResult
BImage
RIV_PA_BMeasResult
CImage
RIV_PA_CMeasResult
DImage
RIV_PA_DMeasResult
[B] Image
RIV_PA_BSMeasResult
TOFDImage
RIV_PA_TFMeasResult
AWaveEcho
RIV_PA_APicture
B Image
RIV_PA_BPicture
C Image
RIV_PA_CPicture
D Image
RIV_PA_DPicture
[B] Image
RIV_PA_BSPicture
TOFD Image
RIV_PA_TFPicture
B-3
Keywords for TOFD Report
Appendix C Keywords for TOFD Report Item
Name
ChannelInfo
RIV_ChannelParam
TOFDProbe SettingInfo
SettingInfo RIV_TF_X_Para m
AngleProbeS ettingInfo
Keyword ProbeType
RIV_TF_X_ProbeType
ProbeFreq
RIV_TF_X_ProbeFreq
ProbeDiameter
RIV_TF_X_ProbeDiameter
LongitudinalVel
RIV_TF_X_LongitudinalVel
WedgeAngle
RIV_TF_X_WedgeAngle
WedgeVel
RIV_TF_X_WedgeVel
FocusPosition
RIV_TF_X_FocusPosition
CalcRule
RIV_TF_X_CalcRule
Gain
RIV_TF_X_Gain
Comp.
RIV_TF_X_Repair2
Range
RIV_TF_X_Range
TimeWindow
RIV_TF_X_TimeWindow
DispDelay
RIV_TF_X_PulseDelay
ProbeDelay
RIV_TF_X_ProbeDelay
PulseVoltage
RIV_TF_X_PulseVoltage2
PulseWidth
RIV_TF_X_PulseWidth
Damping
RIV_TF_X_Damping
PRF
RIV_TF_X_PulsePRF
FrequencyBand
RIV_TF_X_FrequencyBand
WorkpieceThicknes s
RIV_TF_X_WorkpieceThickness
PCSValue
RIV_TF_X_PCSValue
Average
RIV_TF_X_Average
ChannelOffset
RIV_TF_X_ChannelOffset
LayerStart
RIV_TF_X_LayerStart
LayerEnd
RIV_TF_X_LayerEnd
X_ScanTotalDist (SS)
RIV_TF_X_ScanTotalDist
ScanLeakDist (LS)
RIV_TF_X_ScanLeakDist
ProbeType
RIV_TF_X_ProbeType
ProbeFreq
RIV_TF_X_ProbeFreq
ProbeAngle
RIV_TF_X_ProbeAngle
ProbeKValue
RIV_TF_X_ProbeKValue
ProbeXValue
RIV_TF_X_ProbeXValue
ProbeLenA
RIV_TF_X_ProbeLenA
ProbeLenB
RIV_TF_X_ProbeLenB
Position
RIV_TF_X_Position
C-1
Keywords for TOFD Report
Item
Name
AngleProbeS ettingInfo
SettingInfo RIV_TF_X_Para m (Continued)
CreepProbe SettingInfo
Keyword CoverType
RIV_TF_X_CoverType
MaterialVel
RIV_TF_X_MaterialVel
EchoType
RIV_TF_X_EchoType
Gain
RIV_TF_X_Gain
Comp.
RIV_TF_X_Repair2
Range
RIV_TF_X_Range
TimeWindow
RIV_TF_X_TimeWindow
DispDelay
RIV_TF_X_PulseDelay
ProbeDelay
RIV_TF_X_ProbeDelay
PulseVoltage2
RIV_TF_X_PulseVoltage2
PulseWidth
RIV_TF_X_PulseWidth
Damping
RIV_TF_X_Damping
PRF
RIV_TF_X_PulsePRF
FrequencyBand
RIV_TF_X_FrequencyBand
Rectify
RIV_TF_X_Rectify
WorkpieceThicknes s
RIV_TF_X_WorkpieceThickness
PWSValue
RIV_TF_X_PWSValue
Average
RIV_TF_X_Average
ChannelOffset
RIV_TF_X_ChannelOffset
ScanTotalLength(S S)
RIV_TF_X_ScanTotalDist
ScanLeakLength(L S)
RIV_TF_X_ScanLeakDist
ProbeType
RIV_TF_X_ProbeType
ProbeFreq
RIV_TF_X_ProbeFreq
ProbeXValue
RIV_TF_X_ProbeXValue
Position
RIV_TF_X_Position
MaterialVel
RIV_TF_X_MaterialVel
EchoType
RIV_TF_X_EchoType
Gain
RIV_TF_X_Gain
Comp.
RIV_TF_X_Repair2
Range
RIV_TF_X_Range
TimeWindow
RIV_TF_X_TimeWindow
DispDelay
RIV_TF_X_PulseDelay
ProbeDelay
RIV_TF_X_ProbeDelay
PulseVoltage2
RIV_TF_X_PulseVoltage2
PulseWidth
RIV_TF_X_PulseWidth
Damping
RIV_TF_X_Damping
PRF
RIV_TF_X_PulsePRF
FrequencyBand
RIV_TF_X_FrequencyBand
Rectify
RIV_TF_X_Rectify C-2
Keywords for TOFD Report
Item
Name
CreepProbe SettingInfo
SettingInfo RIV_TF_X_Para m (Continued)
SuporSetting Info
MeasureResult RIV_MeasResul t
Keyword WorkpieceThicknes s
RIV_TF_X_WorkpieceThickness
PWSValue
RIV_TF_X_PWSValue
Average
RIV_TF_X_Average
ChannelOffset
RIV_TF_X_ChannelOffset
ScanTotalLength(S S)
RIV_TF_X_ScanTotalDist
ScanLeakLength(L S)
RIV_TF_X_ScanLeakDist
ProbeFreq
RIV_TF_X_ProbeFreq
ProbeDiameter
RIV_TF_X_ProbeDiameter
LongitudinalVel
RIV_TF_X_LongitudinalVel
WedgeAngle
RIV_TF_X_WedgeAngle
WedgeVel
RIV_TF_X_WedgeVel
GrooveTopWidth
RIV_TF_X_GrooveTopWidth
GrooveBottomWidt h
RIV_TF_X_GrooveBottomWidth
FocusPosition
RIV_TF_X_FocusPosition
CalcRule
RIV_TF_X_CalcRule
Gain
RIV_TF_X_Gain
Range
RIV_TF_X_Range
TimeWindow
RIV_TF_X_TimeWindow
DispDelay
RIV_TF_X_PulseDelay
ProbeDelay
RIV_TF_X_ProbeDelay
DualProbe
RIV_TF_X_DualProbe
PulseVoltage2
RIV_TF_X_PulseVoltage2
PulseWidth
RIV_TF_X_PulseWidth
Damping
RIV_TF_X_Damping
PRF
RIV_TF_X_PulsePRF
FrequencyBand
RIV_TF_X_FrequencyBand
Rectify
RIV_TF_X_Rectify
FineGain
RIV_TF_X_FineGain
WorkpieceThicknes s
RIV_TF_X_WorkpieceThickness
PCSValue
RIV_TF_X_PCSValue
Average
RIV_TF_X_Average
ChannelOffset
RIV_TF_X_ChannelOffset
LayerStart
RIV_TF_X_LayerStart
LayerEnd
RIV_TF_X_LayerEnd
AWaveEcho
RIV_TF_AMeasRe sult
BImage
RIV_TF_BMeasRe C-3
Keywords for TOFD Report
Item
Name
Keyword sult
Image RIV_Picture
AWaveEcho
RIV_TF_APicture
BImage
RIV_TF_BPicture
C-4
Keywords for Conventional UT Report
Appendix D Keywords for Conventional UT Report Item
Name
ChannelInfo
RIV_UT_Groups_Param
ScanInfo RIV_UT_X_Scan_Param
Keyword
Calibration
RIV_X_CalibStates
MaterialType
RIV_X_MaterialType
EchoType
RIV_X_EchoType
MaterialVel
RIV_X_MaterialVel
WorkpieceThickness
RIV_X_WorkpieceThickness
PulseVoltage
RIV_X_PulseVoltage2
PulseWidth
RIV_X_PulseWidth
Damping
RIV_X_Damping
PRF
RIV_X_PulsePRF
DualProbe
RIV_X_DualProbe
Range
RIV_X_Range
DispDelay
RIV_X_PulseDelay
Gain
RIV_X_Gain
FrequencyBand
RIV_X_FrequencyBand
AnalogFilter
RIV_X_AnalogFilter
Rectify
RIV_X_Rectify
Sur_Comp
RIV_X_Repair
FineGain
RIV_X_FineGain
Reject
RIV_X_Reject
ProbeAngle
RIV_X_ProbeAngle
ProbeKValue
RIV_X_ProbeKValue
ProbeXValue
RIV_X_ProbeXValue
ProbeDelay
RIV_X_ProbeDelay
Distance E
RIV_X_SimulWkpcDistE
ChannelOffset
RIV_X_ChannelOffset
AutoFreeze
RIV_X_AutoFreeze
Sec.Color
RIV_X_SecWaveColor
WaveComp
RIV_X_WaveComp
WaveFill
RIV_X_WaveFill
PeakEvo
RIV_X_PeakEnvCtrl
WeldSimu
RIV_X_WeldSimulSwitch
Dr
RIV_X_Dr
K
RIV_X_K
Di
RIV_X_Di
AWSOps
RIV_X_AWSOps
B Ref Ha
RIV_X_B_Ref_Ha D-1
Keywords for Conventional UT Report
Item
ScanInfo RIV_UT_X_Scan_Param (Continued)
GateInfo RIV_UT_X_Gate_Param
Name
Keyword
B Ref
RIV_X_B_Ref
CSCType
RIV_X_CSCType
OutDiam
RIV_X_OutDiam
CrackHeight1
RIV_X_CrackHeight1
CrackHeight2
RIV_X_CrackHeight2
CrackResult
RIV_X_CrackResult
Curve
RIV_X_Curve
DACCriterion
RIV_X_DACCriterion
DACLevel
RIV_X_DACLevel
CurveNum
RIV_X_CurveNum
CurveType
RIV_X_CurveType
CurveSel
RIV_X_CurveSel
DACDisplay
RIV_X_DACDisplay
DACCurve1
RIV_X_DACCurve1
DACCurve2
RIV_X_DACCurve2
DACCurve3
RIV_X_DACCurve3
DACCurve4
RIV_X_DACCurve4
DACCurve5
RIV_X_DACCurve5
DACCurve6
RIV_X_DACCurve6
ProbeName
RIV_X_ProbeName
ProbeType
RIV_X_ProbeType
ProbeShape
RIV_X_ProbeShape
AVGFreq
RIV_X_AVGFreq
AVGLenA
RIV_X_AVGLenA
AVGLenB
RIV_X_AVGLenB
AVGBaseType
RIV_X_AVGBaseType
AVGBaseAperture
RIV_X_AVGBaseAperture
AVGCurve1
RIV_X_AVGCurve1
AVGCurve2
RIV_X_AVGCurve2
AVGCurve3
RIV_X_AVGCurve3
Attenuation
RIV_X_Attenuation
AVGMode
RIV_X_AvgMode
K1/K2Calib
RIV_X_K1K2Corr
FlawLengthSW
RIV_X_FlawLengthSW
FlawLength
RIV_X_FlawLength
AVGDisplay
RIV_X_AVGDisplay
GateALogic
RIV_X_GateALogic
GateAStart
RIV_X_GateAStart
GateAWidth
RIV_X_GateAWidth
GateAThresh
RIV_X_GateAThresh
GateAMeasPoint
RIV_X_GateAMeasPoint
D-2
Keywords for Conventional UT Report
Item
Name
Keyword
GateBLogic
RIV_X_GateBLogic
GateBStart
RIV_X_GateBStart
GateBWidth
RIV_X_GateBWidth
GateBThresh
RIV_X_GateBThresh
GateBMeasPoint
RIV_X_GateBMeasPoint
GateCLogic
RIV_X_GateCLogic
GateCStart
RIV_X_GateCStart
GateCWidth
RIV_X_GateCWidth
GateCThresh
RIV_X_GateCThresh
GateCMeasPoint
RIV_X_GateCMeasPoint
MeasResult RIV_MeasResult
AWaveEcho
RIV_UT_AMeasResult
BImage
RIV_UT_BMeasResult
Image RIV_Picture
AWaveEcho
RIV_UT_APicture
BImage
RIV_UT_BPicture
GateInfo RIV_UT_X_Gate_Param (Continued)
D-3
Keywords for TG Report
Appendix E Keywords for TG Report Item
LCPInfo RIV_LCP_Param
ProbeInfo RIV_Probe_X_Param
SettingInfo RIV_TG_X_Param
Name
Keyword
FileFormat
RIV_LCP_FileFormat
Row
RIV_LCP_Row
Column
RIV_LCP_Column
PointNum
RIV_LCP_PointNum
LineColRoll
RIV_LCP_LineColRoll
DispModeLine
RIV_LCP_DispModeLine
DispModeCol
RIV_LCP_DispModeCol
RollMode
RIV_LCP_RollMode
ProbeName
RIV_Probe_X_Name
ProbeType
RIV_Probe_X_Type
ProbeFreq
RIV_Probe_X_Freq
ProbeDiameter
RIV_Probe_X_Diameter
Remark
RIV_Probe_X_Remark
CurrChannel
RIV_X_Channel
Range
RIV_X_Range
DispDelay
RIV_X_DispDelay
MaterialVel
RIV_X_MaterialVel
ProbeDelay
RIV_X_ProbeDelay
Gain
RIV_X_Gain
Rectify
RIV_X_Rectify
MeasObject
RIV_X_MeasObj
LineSelect
RIV_X_VPathSet
WorkMode
RIV_X_WorkMode
MeasFreq
RIV_X_MeasFreq
GateALogic
RIV_X_GateALogic
GateAStart
RIV_X_GateAStart
GateAWidth
RIV_X_GateAWidth
GateAThresh
RIV_X_GateAThresh
GateBLogic
RIV_X_GateBLogic
GateBStart
RIV_X_GateBStart
GateBWidth
RIV_X_GateBWidth
GateBThresh
RIV_X_GateBThresh
ThicknessList
RIV_ThicknessList
Image
RIV_Picture
E-1