PROPOSED TWO-STOREY RESIDENTIAL HOUSE PHAS PH ASE E 7-A BLOCK BLOCK 17 17 LOT 04 ORC ORCHA HARD RD & RES RESID IDEN ENTIA TIAL L ESTA ESTATE, TE, SAL SALITR ITRAN AN,, DASMA DASMARI RI
Page 1 of 16
Owner: MS. LYDA B. FIX DESIGN OF SLABS A. DESIGN OF TWO-WAY SLAB (S-1) Direct Design Method Design Specifications L1 = 2.30 m L2 =
column size =
3.35 m 275 Mpa
Fy =
0.20m x 0.40m
a1 =
1
beam size = 0.20m x 0.35m f'c = 20.7 Mpa
a2 = cc =
1.25 25
Considering the interior slab 1 Relative a values 1.46 a1 x L2 /L1 = 0.86 a2 x L1 /L2 = 2 Slab thickness, t = t
It should not be less than Ln (800 + 0.73Fy) = tmin = 36000 + 9000b
68.27 mm
ok
It should not be more than Ln (800 + 0.73Fy) = tmax = 36000
93.13 mm
ok
Try t =
100 mm for all two way slabs
3 Design moments Dead Load = W slab + W ceiling+finish = Live Load
3.35 Kpa
L1 =
2.3
4.8 Kpa
L2 = =
3.35 0.9
=
46.09
=
f Wu = 1.4DL + 1.7LL (consider 1-m strip) =
Long Span: 2 Mu = Wu L 1 Ln2 /8
=
41.48 KN m;
12.86 Kpa
Mu/f
Mn =
Distribution of Mn between section of positive and negative moment at midspan: +Mms = 0.35 Mn = 16.13 KN m at support: -Ms = 0.65 Mn = -29.96 KN m Percentage of moment at support Column strip: a2 = L1/L2 = 1.25 By interpolation: L1/L2 a2L1/L2 0.5 0.69 1
90 ? 75
x
a2L1/L2 =
0.69
x %M
= =
Code assigns 85% of the column strip moment to the beam Column strip negative Mn = -25.28 KN m Beam negative Mn = -21.49 KN m Slab negative Mn = -3.79 KN m Column strip positive Mn = 13.61 KN m Beam positive Mn = 11.57 KN m Slab positive Mn = 2.04 KN m
Page 2 of 16
0.86
5.60 % 84.40 %
=
-1.90 KN m /hal
=
1.02 KN m /hal
Middle strip (takes the remaining moment) -4.67 KN m Middle strip negative Mn = Middle strip positive Mn = 2.52 KN m
Short Span: 2 Mu = Wu L 2 Ln1 /8
=
28.48 KN m;
Mu/f
Mn =
=
31.64
Distribution of Mn between section of positive and negative moment at midspan: +Mms = 0.35 Mn = 11.07 KN m at support: -Ms = 0.65 Mn = -20.57 KN m Percentage of moment at support Column strip: a1 = 1 L2/L1 =
a1L2/L1 =
1.46
1.46
By interpolation: L2/L1
a1L2/L1
1 75 x x = 1.46 ? %M = 2 45 Code assigns 85% of the column strip moment to the beam Column strip negative Mn = -12.61 KN m Beam negative Mn = -10.72 KN m Slab negative Mn = -1.89 KN m
=
-0.95 KN m /hal
Column strip positive Beam positive Slab positive
=
0.51 KN m /hal
Mn Mn Mn
= = =
6.79 KN m 5.77 KN m 1.02 KN m
13.70 % 61.30 %
Middle strip (takes the remaining moment) Middle strip negative Mn = -7.96 KN m 4.29 KN m Middle strip positive Mn = Fy
LONG SPAN
275 Mpa
-M Slab thickness, t (mm) Steel reinforcement f (mm) Middle Strips Strip Width, b (mm) Mn (KN m) Mn (KN m) d (mm) 6 2 As = [Mn(10 )]/[Fy(0.95d)] (mm ) 2 Min As = 0.002bt (mm ) Spacing, S = Af b /As (mm) Max S = 2t (mm) Column Strips Strip Width, b (mm) Mn (KN m) Mn (KN m) d (mm) 6 2 As = [Mn(10 )]/[Fy(0.95d)] (mm ) 2 Min As = 0.002bt (mm ) Spacing, S = Af b /As (mm) Max S = 2t (mm) Adopted Spacing, S (mm) Middle Strips (10mm bars) Column Strips (10mm bars)