Infravera Sdn. Bhd.(920487-X) www.infravera.com No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com
[email protected] (Sales)
[email protected] [email protected] (Tech. Support) Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected]
AQUATOR VERSION 2 MODELING AT CAD
ITEM
1. Clean The Drawing a. Faster analysis in the software b. Prevent bad/error entities c. More accurate result d. Smoother modeling experience 2. Scale a. To prevent error or
i. ii.
STEP Ensure the drawing does not contain 3D element /entities. To ensure higher quality of clean drawing, copy ne cessary layers and paste to a new drawing.
i.
The best scale to import to the Aquator is 1:1.
i.
Select LAYERS
ii.
Select NEW
entities
3. Add New Layers a. CSSS-USERWATER
icon
icon to add new layers.
iii. Type for new layer (make sure in capital letter and spell with right ) and change any colour user want; a. CSSS-USERWATER NEW layer icon Select NEW layer
Insert both layer names
Page 1 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
ITEM
4. Draw water reticulation lines. a. Need to use single line to draw. b. Make sure stop at intersection.
STEP a) CSSS-USERWATER i.
Make sure change the current layer to CSSS-USERWATER
ii. Select single line
and start to draw the water reticulation line.
iii. Make sure draw the single line and stop at every intersection. iv. Node will be created based the mouse click.
WATEREC LINE
5. Save project a. Project need to be
i.
Select FILE.
ii.
Select SAVE AS to save the project. SELECT FILE
close before import the drawing into the INFRAVERA software
SELECT SAVE AS
iii. Save the project iv. Close/Exit the project before import into the software
Page 2 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
SOFTWARE
1. IMPORT DRAWING
STEP
1. Select the CAD IMPORT
button.
2. Located the CAD drawing. SELECT CAD IMPORT
3. Drawing Scale will pop up after select the CAD drawing. 4. Select ACCEPT for drawing scale.
SELECT ACCEPT
5. Water Supply Guideline will pop up, select the design guide based the project. 6. For example, select SYABAS.
i. SELECT SYABAS
ii. SELECT OK
7. The layout CAD will appear.
Page 3 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
2. WATER TAB STEP 1. Select WATER tab to start design water reticulation SELECT WATER TAB
2. To show the water reticulation line only, pre ss space bar at keyboard
Page 4 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
3. ADD TAPPING POINT & PRESSURE HEAD STEP 1. Select first node as tapping point. In yellow colour, the node is selected. 2. Go to properties tab
, at left hand side software.
3. At properties tab, Input term, change tapping point to TRUE. 4. Indicate the value for tapping pressure head by insert the number.
CHANGE TO TRUE
KEY IN THE PRESSURE HEAD VALUE
4. WATER DEMAND (Q) i)
Have two method’s to key in;
a. By Table b. By Properties
STEP a.
By table
1. Select last nodes, for example, node number 5. 2. By right click mouse at nodes, the mouse properties will pop up. 3. Select for table.
Page 5 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
i. SELECT THE NODES
ii. SELECT TABLE
4. Table for water demand will pop up. 5. Select ADD
button to add the table.
6. Select CALC
button to calculate the sub total Q.
7. Item for type of house, unit of house and water demand unit can be choosing based user. 8. Select OK
if satisfied with the data.
i. SELECT ADD ii. SELECT CALC
BUTTON
BUTTON
iii. SELECT OK BUTTON
9. Done water demand for that node. b. By Properties 1. Select the nodes, and go to properties. 2. Indicate the level for that water demand manually. 3. For example, 0.52.
Page 6 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
KEY IN THE WATER DEMAND
SELECT THE NODES
4. Press ENTER button at keyboard.
5. HYDRANT STEP 1. Select the nodes. 2. Go to properties, select for Hydrant. 3. Change the hydrant to TRUE.
SELECT THE NODES
CHANGE HYDRANT TO TRUE
4. Hydrant will pop up at layout.
Page 7 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
6. FITTING/PUMP STEP 1. By select the pipe, right click mouse at that pipe. 2. Select for fitting or pump. If select for fitting, choose the types o f fitting to add on. 3. For example, select for air valve fitting.
ii. SELECT AIR VALVE
i. SELECT FITTING
4. Air valve fitting icon will appear at layout. 5. Key in the head loss for air valve, by select component
at properties.
ii. KEY IN THE HEAD LOSS
i. SELECT THE COMPONENT
Page 8 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
7. RUN RESULT STEP 1. Select INTEGRITY
icon before run.
2. INTEGRITY PASS information will pop up. 3. Select OK button
SELECT OK
4.
The output data can be check at information tab (below tab)
8. SECTIONS STEP
1. Select SECTIONS
icon.
SELECT SECTIONS
2. Section Data will be appearing at le ft side. Tick all the section. 3. Select BUILD button to generate section.
Page 9 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
STEP
TICK ALL THE SECTION
SELECT BUILD
4. Section will appear at section layout. 5. To change the datum of slope, select SETUP
button.
6. Setup for CAD section will pop up, search for DATUM, and change the value. For example 80. 7. Done change the datum value, select OK button. 8. The data need to be change by re-select BUILD button. 9. The section with new datum will be pop up again at layout section too.
CHANGE THE DATUM VALUE
SELECT OK BUTTON
Page 10 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
10. 3D VIEW i) To view data input in 3D environment. STEP 1. Select 3D View
icon.
2. 3D image will appear.
11. CALCULATION i) Break down water reticulation calculation. STEP
. Select Calculation
icon.
2. The data calculation table will be pop up. 3. Click Select All
button, and then Select show
button.
4. The calculation will be appear.
Page 11 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
STEP SELECT ALL BUTTON SELECT SHOW
12. SAVE PROJECT STEP 1. Select file
icon.
2. Select save as to save the project.
SELECT SAVE AS
3. Make sure save the project in one’s folder.
Page 12 of 13
Infravera Sdn. Bhd.(920487-X) No 6-3, JalanPuteri 2/4, Bandar PuteriPuchong, 47100 Puchong, Selangor. Website : www.infravera.com Tel: 03-8063 5733 Fax: 03-8051 4637 Email:
[email protected] (Sales)
[email protected] (Tech. Support)
13. GENERATE REPORT STEP 1. Select REPORT
tab. SELECT REPORTS TAB
2. Select WATER iconto generate the report. 3. The report will be pop up. 4. To change the format of report,select file and select EXPORT DOCUMENT and choose the format. 5. Or user also can select Export Document
icon to change the format.
Page 13 of 13