Tension members 3.2-1. The tension member shown in Figure P3.2-1 is a PL 1 2 8 of A36 steel. The member 1 is connected to a gusset plate with 1 8 -inch-diameter bolts. It is subjected to the dead and live loads shown. Does this member have enough strength? Assume that Ae An .
PL
1
2
8
D = 95k L = 9k
Solution Load combination: 1. Pu 1, 2 D 1, 6 L (1, 2 95) (1, 6 9) 128, 4 kips 2. Pu 1, 4 D 1, 4 95 133 kips So Pu 133 kips
1 Ag 8 4 in.2 2 Required gross area: 1 1 9 in. in. in. 3,375 in. 8 2 8 Required net area: Pu 133 kips > t Fy Ag 0,9 36 4 129, 6 kips Not ok An Ae Ag Aholes 4 in.2
Pu 133 kips > t Fu Ae 0, 75 58 ksi 3, 375 in.2 146,812 kips
Both conditions appear to be unsatisfied with the factored load So, the member does not have enough strength
Not ok
7 3.2-2. A C8 11,5 is connected to a gusset plate with 8 -inch-diameter bolts as shown in Figure P3.2-2. The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total service load capacity if the live-to-dead load ratio is 3? Assume that Ae 0,85 An . C 8 11,5
Solution Fy 50 ksi Fu 65 ksi Gross area: Net area:
Ag 3,38 in.2
An Ag Aholes
(From the manual) 7 1 3,38 2( )0, 22 2,94 in.2 8 8
2 Effective area: Ae 0,85 An 0,85 2,94 2, 45 in. P min (t Pn ) yield ; (t Pn ) fracture min t Fy Ag ; t Fu Ae The factored load: u Pu min 0,9 50 3,38 ; 0, 75 65 2, 45 min 152,1 ; 119, 437
Pu 119, 437 kips Ultimate load: Pu 1, 2 D 1, 6 L 6 D P 119, 437 D u 19,906 kips 6 6 Service load: Ps D L L 3 L 3D But: D Ps 4 D 4 19,906 Ps 79, 624 kips
3.2-2. A C12 30 is connected with a line of 1-inch-diameter bolts in each flange as shown is F 50 ksi Figure P3.2-3. If y and Fu 65 ksi , what is the tensile design strength? Assume that Ae 0,9 An .
Solution