03/10/13
Hyper M esh and BatchM esher
Control Control Cards Cards
Control Control card c ard entities are used to create solver solver control cards s uch as results file I/O I/O options, CPU and memory limits, and and others. A solv s olver er interface interface template must be loaded loaded which defines defines control cards in order to create and Browser er . edit control cont rol cards. Control cards are shown under the Card folder within the M odel Brows The following following panels panels can be used to create and edit control cards: control cards
Solver Card Support Sup port for Control Control Cards RADIOSS (Block Format)
Supporte d Ca rd
Solve r De scription
/ADMESH/GLOBAL
Defines the global parameters.
/ALE/DISP
Describes the displacement formulation.
/ALE/DONEA
Describes the ALE grid velocity.
/ALE/SPRING
Describes the spring formulation.
/ALE/STANDARD
Describes the s tandard tandard formulation.
/ALE/ZERO
Describes the Euler
fi le:///C :/Altai r /hw10.0/help/hm/hmbat.htm
Supporte d Parameters
HyperMesh Notes
1/33
03/10/13
Hyper M esh and BatchM esher
formulation. /ANALY
Describes the analysis flags.
/ARCH
Describes the architecture flag.
/BEGIN
Sets the run name.
/CAA
Describes the computation Aero-Acoustic formulation.
/DAMP
Describes the Rayleigh damping.
/DEF_SHELL
Describes the shell default values initialization.
/DEF_SOLID
Describes the solid default values initialization.
/INISTA
Describes the initial state file.
/IOFLAG
Describes the t he input-output input-output flags.
/MEMORY
Des cribes the memory request.
/RANDOM
Describes the nodal random noise.
/REFSTA
Describes the reference reference state stat e files.
/SPHGLO
Describes the SPH S PH global parameters.
/SPMD
Describes the SPMD computation.
/TITLE
Describes the title.
/UNIT
Describes the local unit system.
/UPWIND
Describes the upwind coefficient.
RADIOSS (Bulk Data Format), OptiStruct
HyperMesh control cards are used to support many different things for the RADIOSS (Bulk Data), OptiStruct user profile. The following I/O option entries are supported as control cards in HyperMesh when appearing before the first fi le:///C :/Altai r /hw10.0/help/hm/hmbat.htm
2/33
03/10/13
Hyper M esh and BatchM esher
SUBCASE statement. s tatement. In many many cases, c ases, inf i nformation ormation supplied supplied on these entries entries is overrid overridden den by repeated repeated definitions definitions within subcases. s ubcases. Supporte d Ca rd
Solve r De scri pti on
ACCELERATION ACCELERAT ION
Controls Controls the t he output of acceleration results
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
ANALYSIS
Flag indicating that only analysis is to be performed (i.e. no optimiz ation), CHECK overrides ANALYSIS.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
CHECK
Flag indicating that only a check run is to be performed (i.e. no analysis or optimization). CHECK overrides ANALYSIS.
CSTRAIN
Controls Controls the t he output of strain results for composite shells.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
CSTRESS
Controls the output of stress results for composite shells.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
DAMAGE
Controls the output of fatigue damage damage results. results .
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
DENSITY
Controls Controls the t he output of density results from a topology or freesize optimization.
DENSRES
Controls Controls the t he output of density results from a topology or freesize optimization.
DESHIS
Controls the creation of the .hgdata file.
fi le:///C :/Altai r /hw10.0/help/hm/hmbat.htm
Supporte d Parameters
HyperMesh Notes
3/33
03/10/13
HyperMesh and BatchMesher
DISPLACEMENT
Controls the output of displacement (and rotation) results.
DMIGNAME
Defines the name given to the reduced matrices written to an external data file.
ECHO
Controls the echo of input data to the .out or .echo files.
EIGVNAME
Defines the prefix to be used for the saving and retrieval of external eigenvalue data files.
ELFORCE
Controls the output of element force results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
ESE
Controls the output of element strain energy results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
FLUX
Controls the gradient and flux output for heat transfer analysis.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
FORMAT
Controls the format of results output.
Formats are: H3D (default), HM, FLX, OPTI, OUTPUT2, PUNCH, PATRAN, APATRAN, NONE.
GPFORCE
Controls the output of grid point force results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
GPSTRESS
Controls the output of grid point stress results (available for PSOLID components only).
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
4/33
03/10/13
HyperMesh and BatchMesher
HISOUT
Controls the contents of the .hgdata file.
INFILE
When using the t wo-file setup, INFILE indicates the prefix of the file containing the bulk data information.
Its extension must be .fem.
LIFE
Controls the output of fatigue life results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
LOADLIB
Defines the libraries to be loaded for external responses (DRESP3).
MBFORCE
Requests force output for a set of joints and/or force elements from multi-body dynamics subcases.
MODEL
Requests output for all formats for only a subset of the model and results.
This option is intended for multi-body dynamics and transient solution sequences with which users often require results for only a subsection of a model, but it is applied to all solution sequences.
MPCFORCES
Controls the output of MPC force results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
OFREQUENCY
Defines a set of frequencies at which results are output for frequency response analysis.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
OLOAD
Controls the output of applied force results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
OTIME
Defines a set of times at which results are output for transient analysis.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
5/33
03/10/13
HyperMesh and BatchMesher
OUTFILE
Defines the path to, and the prefix of, the results files output by RADIOSS (Bulk Data), OptiStruct.
OUTPUT
Controls the frequency and format of results output by RADIOSS (Bulk Data), OptiStruct.
PRESSURE
Controls the output of pressure results.
PROPERTY
Controls the output of the property definitions used in the last iteration of an optimization.
RESPRINT
Controls the output of unretained optimization constraints.
RESTART
Flag that indicates that a restart run is to be performed. Also indicates the prefix of the .sh file to be used as the starting iteration for the restart.
RESULTS
Controls the frequency of output of analytical results during an optimization.
SCREEN
Controls the information echoed to the screen during a run.
SENSITIVITY
Controls the output of responses and sensitivities for size and shape design variables to a Microsoft Excel spreadsheet.
SENSOUT
Controls the frequency of output of responses and sensitivities to a Microsoft Excel spreadsheet.
SHAPE
Controls the output of shape optimization results from a shape, topography or freeshape optimization.
SHRES
Controls the frequency of
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
6/33
03/10/13
HyperMesh and BatchMesher
output of the state files (.sh and .grid). SPCFORCES
Controls the output of singlepoint force of constraint results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
STRAIN
Controls the output of elemental strain results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
STRESS
Controls the output of elemental stress results.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
SUBTITLE
Defines a default subtitle for a RADIOSS (Bulk Data), OptiStruct model.
Individual subcases may have their own SUBTITLE definitions which are supported on the subcase definition (use the edit button in the loadsteps panel). These will override the default subtitle.
THERMAL
Controls the temperature output for heat transfer analysis.
Supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
THICKNESS
Controls the output of thickness results from topology, free-size, or size optimization.
TITLE
Defines a title for a RADIOSS (Bulk Data), OptiStruct model.
TMPDIR
Defines a temporary directory where scratch files will be written.
RADIOSS (Bulk Data), OptiStruct allows multiple TMPDIR entries, but only one instance is currently supported in the HyperMesh interface.
VELOCITY
Controls the output of velocity results.
Supported as an output option on the subcase definition when it appears
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
7/33
03/10/13
HyperMesh and BatchMesher
within a subcase. (Use the edit button in the loadsteps panel).
The following Global Matrix Selectors are supported as control cards in HyperMesh: Global Matrix Selector
Solver Description
B2GG
Identifies a DMIG bulk data entry as a viscous damping matrix.
K2GG
Identifies a DMIG bulk data entry as a stiffness matrix.
K42GG
Identifies a DMIG bulk data entry as a structural element damping matrix.
M2GG
Identifies a DMIG bulk data entry as a mass matrix.
P2G
Identifies a DMIG bulk data entry as a load matrix.
Supported Parameters
HyperMesh Notes
Other RADIOSS (Bulk Data), OptiStruct cards supported as control cards in HyperMesh: Supported Cards
Solver Description
ACMODL
Defines the fluid-structure interface parameters.
CONTPRM
Defines the default properties of all contact s
DESVARG
Defines an override for design variable settings.
DTI_UNITS
Defines units for multi-body dynamics and component mode synthesis solution sequences.
GRDSET
Defines defaults for fields 3, 7, and 8 on all GRID entries.
GAPPRM
Defines parameters for gap element connectivity and configuration.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported Parameters
HyperMesh Notes
The following GAPPRM arguments are supported: CHKRUN, CKGPDIR, GAPCMPL, GAPGPRJ, 8/33
03/10/13
HyperMesh and BatchMesher
HMGAPST, PRTSW, ERRMSG. PARAM
Defines RADIOSS (Bulk Data), OptiStruct run parameters.
The following PARAM arguments are supported: AMLS, AMLSNCPU, AUTOSPC, AUTOSPRT, CB2, CHECKEL, CHKGPDIR, CHECKMAT, CK2, CM2, COUPMASS, CP2, DFREQ, EFFMAS, EXPERTNL, EXTOUT, FLEXH3D, FLIPOK, FZERO, G, GAPOFFSET, INREL, ITAPE, KDAMP, KGRGD, MBDH3D, MODETRAK, OGEOM, OMACHRP, OMID, POST, POSTEXT, PRGPST, REANAL, SORTCON, W3, W4, WTMASS.
STACK
Defines the stacking information and stacking sequence for ply-based composite definition.
SWLDPRM
Defines parameters for The following CWELD connectivity search. SWLDPRM arguments are supported: CHKRUN, GSPROJ, PROJTOL, PRTSW, ERRMSG.
If an unsupported argument is encountered on importing a PARAM card, the data is stored as UNSUPPORTED_PARAMS on the PARAM card. It is also possible to create an unsupported PARAM card using the UNSUPPORTED_PARAMS option.
Other HyperMesh control cards for the RADIOSS (Bulk Data Format), OptiStruct interface: Supported Cards
BULK_UNSUPPORTED_ CARDS
Solver Description
Supported Parameters
HyperMesh Notes
If a line (not a continuation line) occurs after the BEGIN BULK statement in an input file and starts with a keyword that is not recognized or supported, then the entire card gets written to BULK_UNSUPPORTED_CARDS. It is also possible to manually define an unsupported bulk data card using the BULK_UNSUPPORTED_CARDS.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
9/33
03/10/13
HyperMesh and BatchMesher
BULK_UNSUPPORTED_CARDS are exported near the bottom of the exported RADIOSS (Bulk Data), OptiStruct input file, just before the ENDDATA statement. CTRL_UNSUPPORTED_ CARDS
If a line (not a continuation line) occurs before the BEGIN BULK statement and before the first SUBCASE statement and starts with a keyword that is not recognized or supported, then the entire card gets written to CTRL_UNSUPPORTED_CARDS. It is also possible to manually define data cards appearing above the first SUBCASE statement using the CTRL_UNSUPPORTED_CARDS. CTRL_UNSUPPORTED_CARDS are exported near the top of the exported RADIOSS (Bulk Data), OptiStruct input file, just before the first SUBCASE statement.
DEBUG
Some special or custom features can be accessed through the use of 'debug, , ' statements.
GLOBAL_CASE_CONTROL Handles the data selectors FREQ, METHOD, MPC, SDAMPING and SPC appearing above the first SUBCASE statement.
This control card OMODES is also supported as an output option on the subcase definition when it appears within a subcase. (Use the edit button in the loadsteps panel).
It also handles the data selector DESVAR, used to select a set of design variables for use in an optimization run. It also handles the output control OMODES, used to define a set of modes for output requests. INCLUDE_BULK
This control card is retained to support old database files. It is recommended that the Include Browser be used for work involving include files.
INCLUDE_CTRL file:///C:/Altair/hw10.0/help/hm/hmbat.htm
This control card is retained to support old database files. 10/33
03/10/13
HyperMesh and BatchMesher
It is recommended that the Include Browser be used for work involving include files. Model Documentation
$HMBEGINDOC and $HMENDDOC indicate a section of comment cards which are supported on import to and export from HyperMesh. The comments are stored on control card Model Documentation. This information is exported at the top of the exported RADIOSS (Bulk Data), OptiStruct input file.
OSDIAG
Some special diagnostic information can be processed through the use of 'osdiag, , , , ' statements.
RADIOSS (Fixed Format)
Supported Cards
Solver Description
Supported Parameters
HyperMesh Notes
Header Card
Run Description
This card must be selected for HyperMesh to output a valid deck. Specify the run name.
ReadMe
Comment Lines
New comments lines as well as existing RADIOSS (Fixed Format) deck comment lines are stored in this card. If necessary, increase the number of lines in the card.
Title
Title Card
Automatically outputs the title to the header. RADIOSS card number 1
Memory Req
Memory Request
IO flag Card
Input-output flags
RADIOSS card number 3
Input Files
Input Files
RADIOSS card number 4
Analysis Flags
Analysis Flags
RADIOSS card number 5 Optional for parallel arithmetic in Analysis Flags.
Solid Default Flag
Solid Default Flag
Card 2.6 Flag for solid element
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
11/33
03/10/13
HyperMesh and BatchMesher
formulation. Shell Default Flag
Shell Default Flag
Card 2.7 Flag for shell element formulation.
Gen. Parameters
General Parameters
RADIOSS card number 8
No. Elements
Number of Elements
RADIOSS card number 9
Loading Data
Loading Data
RADIOSS card number 10 A gravity option is available. Corresponding gravity functions are defined in the load card. This includes a skew number that refers to a skew frame and scale factor. The first node number is picked from the data. By default, the last node is the last node in the model.
Crash Data 9
Number of Crash entities
RADIOSS card number 11
Airbag 10
Number of Crash entities (cont.)
RADIOSS card number 12
Time History 1 Output Ctrl
Time History Plot Section. (1st part). Must be activated if the output blocks are created.
RADIOSS card number 14
Time History 2 Output Ctrl
Time History Plot Section. (2nd part). Must be activated if the output blocks are created.
RADIOSS card number 15
Control Card 18
Random Noise
RADIOSS card number 20
Abaqus
In HyperMesh, Control Cards define model information, which needs to be specified only once in the input file. The following Abaqus keywords are supported as Control Cards: Supported Card
Solver Description
Supported Parameters
*CONSTRAINT CONTROLS
Reset overconstraint checking controls
NO CHECKS NO CHANGES DELETE SLAVE
*DEPVAR
Specify solution-dependent state variables
*HEADING
Print a heading on the output
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
HyperMesh Notes
12/33
03/10/13
HyperMesh and BatchMesher
*PREPRINT
Select printout for the analysis CONTACT input file processor. ECHO HISTORY MODEL
*RESTART
Save and reuse data and analysis results
READ WRITE STEP INC END STEP FREQUENCY OVERLAY
Actran
The last step before creating the Actran input deck is completing control cards, which define the properties of the model that are not directly related to the mesh. You can define the title, analysis specifications, dimensions of the problem, interfaces between incompatible meshes, a color map and frequency response function solution, external structural vibration, and acoustic sources. Control cards can be accessed from the control cards panel from the Analysis page. Supported Card
Solver Description
Analysis
Specify options about the analysis
Supported Parameters
HyperMesh Notes
Specify: •
•
•
Frequency or modal analysis Frequency range and/or number of modes The solver
AXISYMMETRY
Control card - dimension
BC_MESH
Define an excitation from a previous computation performed in Nastran, Actran, or Abaqus.
The excitation must be defined in two files: a mesh file and a results file defining the vibration on each node.
Dimension
Define the dimension of the problem.
2D, 3D, or axisymmetric
FIELD_SAVE
Output Map
FREQUENCY_DOMAIN
Analysis
Interface
Define interfaces for incompatible meshes.
LIGHTHILL
Use for predicting broadband aero-acoustic noise
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Optional. Each interface must be linked with two coupling surfaces.
13/33
03/10/13
HyperMesh and BatchMesher
MEAN_FLOW
Include a file containing the FLOW data block.
Used for further convected acoustic simulations
MODAL_EXTRACTION
Analysis
OUTPUT_MAP
Define color map solutions
OUTPUT_FRF
Define field points on the model (virtual microphone).
SAVE
Output map
SOLVER
Output map
SOURCE
Define acoustic sources in the model (virtual loudspeaker).
SUPER_ELEMENT
Generate the SUPERELEMENT data block, specifying the OP2 file name.
Title
Specify a name for the analysis.
Optional
ANSYS
The HyperMesh input translator recognizes the ANSYS cards listed below. If HyperMesh finds an unsupported field in a card, a message is displayed on the status bar. The messages are also printed to the file ansys.msg. General slash commands, SOLUTION commands, POST1 commands, and POST26 commands are referred to as control cards. Unrecognized cards are written to a *.hmx file. Supported Card
Solver Description
Supported Parameters
ACEL
Specifies the linear acceleration of the structure.
ACELX, ACELY, ACELZ
ALPHAD
Defines the mass matrix multiplier for damping.
Value
ANTYPE
Specifies the analysis type and restart status.
Type, Status
ARCLEN
Activates the arc length method.
Key, MAXARC, MINARC
ARCTRM
Controls t ermination of the arc- Lab, VAL, NODE, DOF length solution
/ASSIGN
Reassigns a file name to an ANSYS file identifier.
AUTOTS file:///C:/Altair/hw10.0/help/hm/hmbat.htm
HyperMesh Notes
Key 14/33
03/10/13
HyperMesh and BatchMesher
/BATCH
Sets the program mode to "batch"
List
BETAD
Defines the stiffness matrix multiplier for damping.
Value
/BFUNIF
Specifies buckling analysis options
Method, NMODE, SHIFT, LDMULTE
BUCOPT CGLOC
Specifies the origin location of XLOC, YLOC, ZLOC the acc eleration coordinate system.
CGOMGA
Specifies the rotational velocity CGOMX, CGOMY, of the global origin. CGOMZ
CMDOMEGA
Specifies the rotational acceleration of an element component about a userdefined rotational axis.
CM_NAME, DOMEGAX, DOMEGAY, DOMEGAZ, X1, Y1, Z1, X2, Y2, Z2
CMOMEGA
Specifies the rotational velocity of an element component about a user-defined rotational axis.
CM_NAME, DOMEGAX, DOMEGAY, DOMEGAZ, X1, Y1, Z1, X2, Y2, Z2, KSPIN
CNVTOL
Sets convergence values for nonlinear analyses.
Lab, VALUE, TOLER, NORM, MINREF
/COM
Places a comment in the output.
/COPY
Copies a file.
CRPLIM
Specifies the creep criterion for CRCR, Option automatic time stepping.
DCGOMG
Specifies the rotational acceleration of the global origin.
/DELETE
Deletes a file.
DELTIM
Specifies the time step sizes to be used for this load step.
DMPRAT
Sets a constant damping ratio. Value
DOF
Adds degrees of freedom to the current DOF set.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
DCGOX, DCGOY, CZOZ
DTIME, DTMLN, DTMAX Carry
DOMGX, DOMGY, DOMGZ 15/33
03/10/13
HyperMesh and BatchMesher
DOMEGA
Specifies the rotational acceleration of the structure.
EQSLV
Specifies the type of equation solver.
lab, Toler, MULT
ERESX
Specifies extrapoloation of integration point results.
Key
ETABLE
Fills a table of element values for further processing.
LAB, ITEM, COMP
EXPASS
Specifies an expansion pass of Key an analysis.
FINISH
Exits normally from a processor.
HARFRQ
Defines the frequency range in the harmonic response analysis.
FREQB, FREQE
HREXP
Specifies the phase angle for the harmonic analysis expansion pass.
Method, MAXMODE, MINMODE, MCout, Damp
HROPT
Specifies harmonic analysis options.
Reimky, Clust, Mcont
HROUT
Specifies the harmonic analysis output options.
IRLF
Specifies that inertia relief calculations are to be performed.
Key
KBC
Specifies stepped or ramped loading within a load step.
Key
KUSE
Specifies whether or not to Key reuse the triangularized matrix.
LNSRCH
Activates a line search to be used with Newton-Raphson.
LVSCALE
Scales the load vector for mode superposition analyses.
MDAMP
Defines the damping ratios as a function of mode.
MODE
Specifies the harmonic loading MODE, ISYM term for this load step.
MODOPT
Specifies modal analysis options.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Key
STLOC, V1, V2, V3, V4, V5, V6
Method, NMODE, FREQB, FREQE, PRMODE, Nrmkey 16/33
03/10/13
HyperMesh and BatchMesher
MXPAND
Specifies the number of modes NMODE, FREQB, to expand and write for a FREQE, Elcalc, modal or buckling analysis. SIGNIF
NCNV
Sets the key to terminate an analysis.
NEQIT
Specifies the maximum NEQIT number of equilibrium iterations for nonlinear analyses.
NLGEOM
Includes large-deflection effects in a static or full transient analysis.
NROPT
Specifies the Newton-Raphson Option, --, Adptky options in a static or full transient analysis.
NSUBST
Specifies the number of substeps to be taken this load step.
OMEGA
Specifies the rotational velocity OMEGX, OMEGY, of the structure. OMEGZ, KSPIN
OUTRES
Controls the solution data written to the database.
/POST1
Enters the database results post-processor.
/PREP
KSTOP, DLIM, ITLIM, ETLIM, CPLIM
Key
NSBSTP, NSBMAX, NSBMN, Carry
Item, FREQ, Cname
Sskey, Lskey
PRED
Activates a predictor in a nonlinear analysis.
PRESOL
Prints the solution results for elements.
PSTRES
Specifies whether prestress effects are calculated or included.
Key
RSYS
Activates a coordinate system for printout or display of results.
KCN
SLOAD
Loads a pretension section.
SECID, PLNLAB, KINIT, KFD, FDVALUE, LSLOAD, LSLOCK
/SOLU
Enters the solution processor.
SOLU file:///C:/Altair/hw10.0/help/hm/hmbat.htm
17/33
03/10/13
HyperMesh and BatchMesher
SOLVE
Starts a solution.
SSTIF
Activates stress stiffness effects in a nonlinear analysis.
/STITLE
Defines subtitles.
SUBOPT
Specifies options for subspace SUBSIZ, NPAD, iteration eigenvalue extraction. NPERBK, NUMSSI, NSHIFT, Strmck, JCGITR
/SYS
Passes a command string to the operating system.
String
TIME
Sets the time for a load step.
Time
TIMINT
Turns on transient effects.
Key, Lab
TINTP
Defines transient integration parameters.
/TITLE
Defines a main title.
TOFFST
Specifies the temperature offset from absolute zero to zero.
Value
TOTAL
Specifies automatic MDOF generation.
ntot, nrmdf
TREF
Defines the reference temperature for the thermal strain calculations.
tref
TRNOPT
Specifies transient analysis options.
Method, MAXMODE, Dmpkey, MINMODE, MCout, TINTOPT
TUNIF
Assigns a uniform temperature temp to all nodes.
/UNITS
Annotates the database with the system of units used.
Key
GAMMA, ALPHA, DELTA, THETA, OSLM, TOL, --, --, AVSMOOTH, ALPHAF, ALPHAM
Label, LENFACT, MASSFACT, TIMEFACT, TEMPFACT, TOFFSET, CHARGEFACT, FORCEFACT, HEATFACT
LS-DYNA file:///C:/Altair/hw10.0/help/hm/hmbat.htm
18/33
03/10/13
HyperMesh and BatchMesher
*DATABASE_OPTION cards in Keyword are listed from the Setup drop down menu, after selecting Control Cards. An active field is output as the appropriate individual card in the data deck. A control card can be in one of three states: State
Color
Explanation
Undefined
Gray
The control card was either never created or was deleted.
Defined (See Note)
Green
Any control card viewed in the card previewer is activated.
Inactive
Red
A card that has been defined may be disabled. The attributes for that card remain; however, the control card is not output.
Note:
Those control cards that are defined (green in the control card editor) are output.
Default values for attributes are common throughout the card previewer. A default value field has one of the following states: State
Description
Default = ON
In this state, the field label color is yellow and no data entry is allowed.
Default = OVERRIDDEN
To override a default value field, pick the yellow field label. When you override a default value field, the label text color changes to cyan and you can enter data in the field.
The following keywords are supported: Supported Card
Solver Description
*CONTROL_ACCURACY
Define control parameters that can improve the accuracy of the calculation.
*CONTROL_ADAPSTEP
Define control parameters for contact interface force update during each adaptive cycle.
*CONTROL_ADAPTIVE
Activate adaptive meshing.
*CONTROL_ADAPT_ CURVE
To refine the element mesh along a curve.
*CONTROL_ALE
Set global control parameters for the Arbitrary LagrangeEulerian and Eulerian calculations.
*CONTROL_BULK_ VISCOSITY
Reset the default values of the bulk viscosity coefficients
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported Parameters
HyperMesh Notes
19/33
03/10/13
HyperMesh and BatchMesher
globally. *CONTROL_CHECK
Check for various problems in the mesh.
*CONTROL_COARSEN
Adaptively de-refine (coarsen) a shell mesh by selectively merging four adjacent elements into one.
*CONTROL_CONTACT
Change defaults for computation with contact surfaces.
*CONTROL_COUPLING
Change defaults for MADYMO3D/CAL3D coupling.
*CONTROL_CPU
Control CPU time.
*CONTROL_DAMPING
Old LS-DYNA card for input only
*CONTROL_DYNAMIC_ RELAXATION
Initialize stresses and deformation in a model to simulate a preload.
*CONTROL_EFG
Define controls for the meshfree computation.
*CONTROL_ENERGY
Provide controls for energy dissipation options
*CONTROL_EXPLOSIVE_ SHADOW
Compute detonation times in explosive elements for which there is no direct line of sight.
*CONTROL_HOURGLASS
Set the default values of the hourglass control to override the default values.
*CONTROL_IMPLICIT_ AUTO
Define parameters for automatic time step control during implicit analysis.
*CONTROL_IMPLICIT_ BUCKLE
Activate implicit buckling analysis when termination time is reached.
*CONTROL_IMPLICIT_ DYNAMICS
Activate implicit dynamic analysis and define time integration constants.
*CONTROL_IMPLICIT_ EIGENVALUE
Activate implicit eigenvalue analysis and define associated input parameters.
*CONTROL_IMPLICIT_
Activate implicit analysis and
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
20/33
03/10/13
HyperMesh and BatchMesher
GENERAL
define associated control parameters.
*CONTROL_IMPLICIT_ INERTIA_RELIEF
Allows analysis of linear static problems that have rigid body modes.
*CONTROL_IMPLICIT_ LINEAR *CONTROL_IMPLICIT_ MODES
old
Request calculation of constraint and/or attachment modes for later use in modal analysis using *PART_MODES.
*CONTROL_IMPLICIT_ NONLINEAR
old
*CONTROL_IMPLICIT_ SOLUTION
Optional card that applies to implicit calculations.Used to specify whether a linear or nonlinear solution is desired.
*CONTROL_IMPLICIT_ SOLVER
Optional card that applies to implicit calculations. The linear equation solver performs the CPU-intensive stiffness matrix inversion.
*CONTROL_IMPLICIT_ STABILIZATION
Optional card that applies to implicit calculations. Artificial stabilization is required for multi-step unloading in implicit springback analysis.
*CONTROL_IMPLICIT_ TERMINATION
Specify termination criteria for implicit transient simulations.
*CONTROL_MPP_ DECOMPOSITION_ AUTOMATIC
Instructs the program to apply a simple heuristic to try to determine the proper decomposition for the simulation.
*CONTROL_MPP_ DECOMPOSITION_CHECK _SPEED
Modifies t he decomposition depending on the relative speed of the processors involved.
*CONTROL_MPP_ DECOMPOSITION_ CONTACT_DISTRIBUTE
Ensures that the indicated contact interfaces are distributed across all processors, which can lead to better load balance for large contact interfaces.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
21/33
03/10/13
HyperMesh and BatchMesher
*CONTROL_MPP_ DECOMPOSITION_ CONTACT_ISOLATION
Ensures that the indicated contact interferences are isolated on a single processor, which can lead to decreased communication.
*CONTROL_MPP_ DECOMPOSITION_FILE
Allow for pre-decomposition and a subsequent run or runs without having to do the decomposition.
*CONTROL_MPP_ DECOMPOSITION_ METHOD
Specify the decomposition method to use.
*CONTROL_MPP_ DECOMPOSITION_ NUMPROC
Specify the number of processors for decomposition.
*CONTROL_MPP_ Allows display of the final DECOMPOSITION_SHOW decomposition. *CONTROL_MPP_ DECOMPOSITION_ TRANSFORMATION
Specifies transformations to apply to modify the decomposition.
*CONTROL_MPP_IO_ NOD3DUMP
Suppress the output of all dump files.
*CONTROL_MPP_IO_ NODUMP
Suppresses the output of all dump files and full deck restart files.
*CONTROL_MPP_IO_ NOFULL
Suppresses the output of the full deck restart files.
*CONTROL_MPP_IO_ SWAPBYTES
Swap bytes on some of the output files.
*CONTROL_OUTPUT
Set miscellaneous output parameters.
*CONTROL_PARALLEL
Control parallel processing usage for shared memory computers by defining the number of processors invoking the optional consistency of the global vector assembly.
*CONTROL_REMESHING
Provide control over the remeshing of solids which are meshed with the solid tetrahedron element type 13.
*CONTROL_RIGID
Special control options related to rigid bodies and the rigidflexible bodies.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
22/33
03/10/13
HyperMesh and BatchMesher
*CONTROL_SHELL
Provide cont rols for c omputing shell response.
*CONTROL_SOLID
Provide controls for solid element response.
*CONTROL_SOLUTION
Specify the analysis solution procedure if thermal only or coupled thermal analysis is performed.
*CONTROL_SPH
Provide controls for computing SPH particles.
*CONTROL_SPOTWELD_ BEAM
Provides factors for scaling the failure force resultants of beam spot welds as a function of their parametric location on the contact segment and the size of the segment.
*CONTROL_STRUCTURED
Write out a LS-DYNA structured input deck for version 970.
*CONTROL_STRUCTURED Write out a LS-DYNA _TERM structured input deck for version 970. Termination will occur after the structured input file is written. *CONTROL_SUBCYCLE
Control time step subcycling.
*CONTROL_TERMINATION
Stop the job.
*CONTROL_THERMAL_ NONLINEAR
Set parameters for a nonlinear thermal or coupled structural/thermal analysis.
*CONTROL_THERMAL_ SOLVER
Set options for the thermal solution in a thermal only or coupled structural-thermal analysis.
*CONTROL_THERMAL_ TIMESTEP
Set time step controls for the thermal solution in a thermal only or a coupled structural/thermal analysis.
*CONTROL_TIMESTEP
Set structural time step size control using different options.
*DAMPING_FREQUENCY_ Provides approximately RANGE constant damping over a range of frequencies. *DAMPING_GLOBAL file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Define mass weighted nodal 23/33
03/10/13
HyperMesh and BatchMesher
damping that applies globally to the nodes of deformable bodies and to the mass center of rigid bodies. *DAMPING_RELATIVE
Apply damping relative to the motion of a rigid body.
*DATABASE_BINARY_ D3PLOT
Dt for complete output states.
*DATABASE_BINARY_ D3DRLF
Dynamic relaxation database.
*DATABASE_BINARY_ D3THDT
Dt for time history data of element subsets.
*DATABASE_BINARY_ D3DUMP
Binary output restart files. Define output frequency in cycles.
*DATABASE_BINARY_ INTFOR
Dt for output of contact interface data.
*DATABASE_BINARY_ RUNRSF
Binary output restart file. Define output frequency in cycles.
*DATABASE_BINARY_ XTFILE
Flag to specify output of extra time history data to XTFILE at same time as D3THDT file.
*DATABASE_EXTENT_AVS Specify output database to be written. *DATABASE_EXTENT_ BINARY
Specify output database to be written.
*DATABASE_EXTENT_ MOVIE
Specify output database to be written.
*DATABASE_EXTENT_ MPGS *DATABASE_EXTENT_ SSSTAT *DATABASE_SPRING_ FORWARD
Create spring forward nodal force file.
*DATABASE_ SUPERPLASTIC_ FORMING
Specify the output intervals to the superelastic forming output files.
*DATABASE_TRACER
Tracer particles will save a history of either a material point or a spatial point into an
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
24/33
03/10/13
HyperMesh and BatchMesher
ASCII file, TRHIST. MADYMO
Supported Card
Solver Description
GAS
Specify a gas (molecular weight and specific heat coefficients).
Supported Parameters
HyperMesh Notes
Nastran
Supported Card
Solver Description
ACMODL
Defines modeling parameters for the interface between the fluid and the structure.
BEGIN BULK
Designates the end of the Case Control Section and/or the beginning of a Bulk Data Section.
Supported Parameters
HyperMesh Notes
When the model is created from HyperMesh, this card is on by default.
BULK-UNSUPPORTED_ CARD
On import, all unsupported bulk data will be written into this card. You can edit the card.
CASE-UNSUPPORTED_ CARD
If CEND and SUBCASE exist, on import, all unsupported cards between CEND and the first SUBCASE will be written into this card. You can edit the card. If SUBCASE does not exist and BEGIN BULK exists, all unsupported cards between CEND and BEGIN BULK will be written into this card.
CEND
When the model is created from HyperMesh, this card is on by default.
DIAG
Requests diagnostic output or special options.
ENDDATA
Designates the end of the Bulk Data Section.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
When the model is created from HyperMesh, this card is on by default. 25/33
03/10/13
HyperMesh and BatchMesher
EXEC_UNSUPPORTED_ CARDS
If CEND exists in the imported deck, on import, all unsupported cards before CEND will be written into this card. You can edit the card. If CEND does not exist, on import, all unsupported cards before BEGIN BULK will be written into this card.
ID
Specifies a comment.
MAXLINES
Sets the maximum number of output lines.
PARAM
Specifies values for parameters.
SET
Defines a set of element or grid point numbers to be plotted.
The maximum number of lines is 999999999 (Nastran default). ASING, AUTOSPC, BAILOUT, COUPMASS, CURV, CURVPLOT, DDRMM, EPPRT, EPZERO, GRDPNT, K6ROT, MAXRATIO, MPCX, NEWSEQ, OLDSEQ, OUNIT2, POST, PRGPST, SPCGEN, TINY, USETPRT, WTMASS, INREL.
On import, all unsupported PARAM cards are written into the UNSUPPORTED PARAMS block within PARAM CARD in the control cards panel. You can edit this data block.
Only real number sets can be created using control cards. For node and element sets, see Sets.
SOL
Specifies the solution sequence or main subDMAP to be executed.
SUBTITLE
Defines a subtitle that will appear on the second heading line of each page of printer output.
TIME
Sets the maximum CPU and I/O time.
TITLE
Defines a character string that will appear on the first heading line of each page of NX Nastran printer output.
PAM-CRASH
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
26/33
03/10/13
HyperMesh and BatchMesher
Supported Card
Solver Description
ADAPT /
Adaptive Mesh
AIRBAGCHECK
Airbag Check
ALLOCATE
Memory Allocation
ANALYSIS
Analysis
BEAPLOT
Beam Output
CCTRL /
Contact Control Parameters
COUPLING
Coupling
CTRL /
Control
CPULIMIT
CPU Limit
DATACHECK
Cross Reference Data Check
DCOMP
DMP Domain Decomposition
DEBUG
Debug
ECTRL /
Element Control Parameters
ENDDATA
End of Data
FILE
File Name
FREE
HyperMesh Notes
Two request types are supported: default (DFLT) and user-defined. If userdefined is selected, available requests are numbered and displayed.
This card is no longer needed for exporting models.
Cards after the ENDDATA card are ignored.
Output automatically, so a control card for this option is not available. Nonkeyword generated decks are not processed correctly by the input translator.
FZMET /
Frozen Metric
INCLU /
Include File
INPUTVERSION
Input Version
KINJ
Kinematic Joint Parameters
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported Parameters
27/33
03/10/13
HyperMesh and BatchMesher
LIST / NOLIS
Input File Echo
MAXMEMORY
Max Memory
MERGEGAP
Output as LIST [ON|OFF] only; however NOLIS as well as YES|NO modifiers are recognized during input.
Common Node Merge
METRIC
Initial Metric
METRICCHECK
Metric Check
MNTR
Energy Output
NODPLOT
Node Output
OCTRL /
Output Control Parameters
Three requests types are supported: default (DFLT), all (ALL), and user-defined. If user-defined is selected, available requests are numbered and displayed.
PICK / PIPE
Pipe
PREFILTER
Prefilter
Each value defaults to blank.
PRINT / NOPRINT
Output Data Echo
Radio buttons represent the available options for requesting output.
RESTARTFILES
Restart Files
REZONE
Rezone
RUNEND/
End of Run Definition
SCRATCHDIR
Scratch Directory
SHELLCHECK
Shell Check
SHLTHP
Shell Time History Output
Three request types are supported: default (DFLT), all (ALL), and user-defined. If user-defined is selected, available requests are numbered and displayed.
SHLPLOT
Shell Output
Three request types are supported: default (DFLT), all (ALL), and user-defined. If user-defined is selected,
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
28/33
03/10/13
HyperMesh and BatchMesher
available requests are numbered and displayed. SIGNAL
Signaling
SOLID4N
Solid4N
SOLIDCHECK
Solid Check
SOLPLOT
Solid Output
SOLVER
Solver Dependent Output
STOPRUN
Stop Run
SUBDF /
Substructure Definition
Maximum of ten cards.
SUBRUN
Substructure Run
Maximum of two cards.
TCTRL /
Time Step Control Parameters
THPLOT
Time History
TIMESTEP
Time Step
TITLE /
Title
Two request types are supported: default (DFLT) and user-defined. If userdefined is selected, available requests are numbered and displayed.
Three request types are supported: default (DFLT), all (ALL), and user-defined. If user-defined is selected, radio buttons that number the available requests become available.
TRSFM / UNIT
Unit System
VERSION
Version
$Model Documentation
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
The input deck can contain model documentation text that is imported and exported via the comment lines. For decks not written by HyperMesh, all comment lines before the first noncomment line are treated as model documentation. For decks written by HyperMesh, the documentation lines must be placed in a block that 29/33
03/10/13
HyperMesh and BatchMesher
begins with the line $HMBEGINDOC and ends with the line $HMENDDOC. The text can be created and changed using the card previewer PAM-CRASH 2G
Supported Card
Solver Description
Supported Parameters
HyperMesh Notes
NA
Imported Model Documentation
The input deck can contain model documentation text that is imported and exported via the comment lines. For decks not written by HyperMesh, all comment lines before the first non-comment line are treated as model documentation. For decks written by HyperMesh, the documentation lines must be placed in a block that begins with the line $HMBEGINDOC and ends with the line $HMENDDOC. The text can be created and changed using the card previewer. This card is always overwritten by the current model documentation.
NA
Model Documentation
This card is not created during FE input process. You can create this card in HyperMesh, but once this card is defined, only this will be exported. You can access macros from the PAM-CRASH 2G user profile to append or overwrite the information from Imported Model Documentation to this card.
AIRBAGCHECK
Airbag Check
Added in PAM-CRASH 2004
ANALYSIS
Analysis
AUTOSLEEP MERGEGAP file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Common Node Merge 30/33
03/10/13
HyperMesh and BatchMesher
CCTRL /
Contact Control Parameters
This card contains all the information about the interfaces control parameters such as initial penetration.
COUPLING
Coupling
DATACHECK
Data Check
DEBUG
Debug
DCOMP
DMP Domain Decomposition
ECTRL /
Element Control Parameters
This card contains all the information about the element control parameters.
ENDDATA
End of Data
Cards after the ENDDATA card are ignored.
FILE
File Name
INCLU /
Include Cards
INPUTVERSION
Input Version
MAXMEMORY
Max Memory
METRIC/
Initial Metric
METRICCHECK
Metric Check
Added in PAM-CRASH 2004
OCTRL /
Output Control Parameters
This card contains all the information about the output of data, e.g., PRINT, SHLTHP, THPOUTPUT, DSYOUTPUT, GLBTHP, BEAPLOT, etc. In card previewer you have the option of defining all the parameters.
PICK / PIPE
Pipe
RESTARTFILES
Restart Files
RUNEND/
End Of Run Definition
RWALL_KIN_CHECK file:///C:/Altair/hw10.0/help/hm/hmbat.htm
31/33
03/10/13
HyperMesh and BatchMesher
SHELLCHECK
Shell Check
SIGNAL
Signalling
SOLIDCHECK
Solid Check
SOLID4N
Solid4N
SOLVER
Solver
STOPRUN
Stop Run
SUBDF /
Substructure Run
This card must be defined in order to support 4-noded tetra elements by using SOLID / keyword in PAMCRASH 2004. Its value should be set to "YES".
SUBRUN SUBTA /
Substructure Run Link Table
TCTRL /
Timestep Control Parameters
TITLE /
Title
This card contains all the information about the time step control parameters.
TRSFM / UNIT
Unit System Unsupported Cards
All unsupported information found in the input deck is imported in this card. You can edit this card.
PERMAS
The following cards are supported in the PERMAS interface: Supported Card
Solver Description
$COMPONENT
Component Input Bracket Header Line
$ECHO
Controls the echo print of PERMAS data input lines.
$MODDAMP
Definition of viscous or structural modal damping.
file:///C:/Altair/hw10.0/help/hm/hmbat.htm
Supported Parameters
HyperMesh Notes
DOFTYPE KIND TYPE