Contents
Chalmlite™ Version 4.04 - Minimum Requirements.......................... Requirements ........................................3 ..............3 To Install:................................................ Install:.......................................................................... ...................................................... ...............................3 ...3 Project Set-Up ....................................................... .................................................................................. ..........................................5 ...............5 Project Set-Up ....................................................... .................................................................................. ..........................................5 ...............5 Snap Values ...................................................... .................................................................................. ..............................................7 ..................7 Target Grids........................................ Grids.................................................................. ...................................................... ...................................9 .......9 Icon Method - Definition.................... Definition................................................ ...................................................... .................................14 .......14 Icon Method - Placement.......................... Placement.................................................... .....................................................19 ...........................19 Floodlight Method - Definition............................................... Definition........................................................................23 .........................23 Floodlight Method - Placement.............................................. Placement......................................................................26 ........................26 Luminaire Luminaire Control & Zoom..................................... Zoom............................................................... ........................................32 ..............32 My First Room ....................................................... ................................................................................. ........................................40 ..............40 Lighting the room & Reflections.....................................................................47 Reflections.....................................................................47 Predefined Predefined room shapes .................................................... .............................................................................. ............................ 59 Drawing rooms rooms & Ceilings .................................................... .............................................................................63 .........................63 Emergency Emergency Luminaires Luminaires ..................................................... ................................................................................. .............................. 69
Chalmit Lighting
January 2009 Revision 1
Contents
Chalmlite™ Version 4.04 - Minimum Requirements.......................... Requirements ........................................3 ..............3 To Install:................................................ Install:.......................................................................... ...................................................... ...............................3 ...3 Project Set-Up ....................................................... .................................................................................. ..........................................5 ...............5 Project Set-Up ....................................................... .................................................................................. ..........................................5 ...............5 Snap Values ...................................................... .................................................................................. ..............................................7 ..................7 Target Grids........................................ Grids.................................................................. ...................................................... ...................................9 .......9 Icon Method - Definition.................... Definition................................................ ...................................................... .................................14 .......14 Icon Method - Placement.......................... Placement.................................................... .....................................................19 ...........................19 Floodlight Method - Definition............................................... Definition........................................................................23 .........................23 Floodlight Method - Placement.............................................. Placement......................................................................26 ........................26 Luminaire Luminaire Control & Zoom..................................... Zoom............................................................... ........................................32 ..............32 My First Room ....................................................... ................................................................................. ........................................40 ..............40 Lighting the room & Reflections.....................................................................47 Reflections.....................................................................47 Predefined Predefined room shapes .................................................... .............................................................................. ............................ 59 Drawing rooms rooms & Ceilings .................................................... .............................................................................63 .........................63 Emergency Emergency Luminaires Luminaires ..................................................... ................................................................................. .............................. 69
Chalmit Lighting
January 2009 Revision 1
3
Chalml Chalml ite™ Versio Versio n 4.04 4.04 - Minimum Requir Requir ements ements October 2007 Any P.C. presently running Windows 95, 98, 2000, XP XP or N.T.4 (Chalmlite™ will not run on Windows 3.1x) H.D. spare capacity: RAM Screen Resolution Screen Colour Fonts Printer
150 Mb 32 Mb 1024x768 True Color 32(bit) Small Any Windows is using (preferably colour)
To Install:
From the START button go to RUN and type D: SETUP.EXE (or whatever your CD drive letter is) Follow the instructions Setup will give the choice of either accepting the default path for Chalmlite™ location (C:\CHALMLITEV4.04) (C:\CHALMLITEV4.04) or choosing a different path p ath location.
The final question from Setup allows you to have an Icon shortcut placed on your desktop. If you choose not to do this you can operate Chalmlite™ from the Start – Programs – menu bar. The configuration file is CMW.CFG. located in the Chalmlite™ Directory It contains the Pathnames of the following Folders:Photo Projects Pictures
(contains the I.E.S. database photometric files) (contains the project files with *.IN extension) (contains BMP BMP files of Chalmit products and the Printout.txt Printout.txt file) file)
Note: The last three pathnames require trailing back slashes.
Chalmit Lighting
March 2010 Revision 2
4
If you move any of the above folders after installation the CMW.CFG pathnames should be changed to suit. In addition, Set-up loads two other folders: Help (this contains all of Chalmlite™ Help files in HTML format) ha ve been overwritten if you re-install Chalmlite™ Backup (this holds any files that have over an existing installation)
Two validation documents (Val-ext-v4.pdf and Val-int-v4.pdf) can be found in the Help file folder, simply follow the links on the index page when you launch help. These testify to the accuracy of the Chal mlite™ program for Exterior and Interior Calculations. Chalmlite™ Version 4.04 4.04 can be installed onto and accessed via a Network server but is not itself a true Net-workable program. Two users cannot access the program at the same time.
Alternatively Chalmlite™ may be installed onto individual PC’s and the Project Files saved to a Network location for security purposes.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
5
Project Set-Up The first stage of any lighting design is to create a new project. To do this follow the steps outlined below.
You can create a new project by clicking the Projects button.
Creating a new project. o Select File o Select New
Chalmit Lighting
January 2009 Revision 1
Chalmlite V4.04 : Getting Started – Exterior Tutorial
New Project Settings o Job/Project Save Location - You must choose the file directory to save this project to. o Enter FILENAME o Enter PROJECT NAME (if applicable) o Enter SITENAME (if applicable) o Enter ENGINEER (if applicable)
Define Limits window - You must now determine the working area o Enter Width of area o Enter Length of area
Chalmit Lighting
6
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
7
Snap Values Snap Values are the term used to determine where the mouse will be operating from on the page.
The lower right hand corner that is highlighted area shows the use positioning of the mouse on the working area.
Select Snap menu from the toolbar
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
8
Snap - the snap value determines the frequency in metres the mouse is snapping in the working area o Snap Status – remain on o Snap Value – measurement in metres
The lower right hand corner that is highlighted area shows the use positioning of the mouse on the working area.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
9
Target Grids The Target Grid enables You to calculate the lighting levels represented on the project being created.
Select Target Grid menu from toolbar o Define new gri d o New x-y grid
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
The New x-y grid window opens and enables You to determine the proximity for each point.
Target Grid o Left click on the grid to place the first corner on the Target Grid o Click on the opposite corner to secure the grid area
Chalmit Lighting
10
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
11
The Target Grid has now been created displayed here with a selection of grid numbers representing the light levels at specific
The above illustration illustrates how You can manipulate the target grid area to be worked on by deletion of points on the grid.
Select Target Grid menu from toolbar Delete points from inside a polygon o
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
Delete points from inside a polygon Left click on target grid to create the first deletion point o Left click on target grid to create the second deletion point o Left click on target grid to create the third deletion point o
Delete points from inside a polygon Right click on the first deletion point to complete the area to be deleted. o o Click Yes to complete the deletion process
Chalmit Lighting
12
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
13
Shown above is the area deleted from the target area
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
14
Icon Method - Definition The Icon Method enables You to choose the luminaire type used in the project.
Select Lum inaires menu from the toolbar o Icon method o Define luminaire
Define current luminaire icon window opens This enables the use to choose the symbol they would prefer to use for their luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
Define current luminaire window opens You can click the icon to be used to signify the luminaire.
Select Luminaire window opens o You can select the correct category to choose their luminaire o Click OK to continue
Chalmit Lighting
15
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
16
Select Luminaire window opens o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue
Select Luminaire window opens o You can determine the luminaire type to be used in the project. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
17
Select Luminaire window opens o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue
Select Luminaire window opens o You can now choose the product specification within the fluorescent range to be used in the project. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
Define current luminaire icon window opens o Click Edit current description
Define current luminaire icon window o Set l uminaire p arameters window opens Here You can determine the mounting height, tilt, etc o Click OK to continue
Chalmit Lighting
18
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
19
Click OK to complete the process
Icon Method - Placement The Icon Method of placement enables You to place some luminaire icons onto the predetermined working area
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
20
The highlighted area on the toolbar indicates how You can locate a luminiare. Click the Locate luminaire button
The highlighted area on this page is reminding You that they must now specify the (x-y) co-ordinates of the luminaire chosen earlier.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
21
Specify luminaire location button from the toolbar o Left click to specify luminaire location o Move the mouse in the direction you want to aim the luminaire o Right click to complete the process
> The illustration above highlights the position chosen by You for the luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
22
> Select the Copy luminaire button from the toolbar to proceed with copying existing luminaire
Copying a luminaire on Target Grid Left click the existing luminaire on the target grid Left click each of the locations where You would want copy the existing luminaire Right click the Target Grid to finish copying the luminaire Right click to complete the process
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
23
Floodlight Method - Definition The Floodlight Method by definition enables You to define the characteristics of the floodlight l uminare.
Select Luminaires menu from the toolbar o Select Floodlight method o Left click to select Define floodlight menu item
Pick current beam pattern window opens o Select colour to represent different luminaires o Click Choose floodlight button
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
24
Select Luminaire window opens o You can select the correct category to choose their luminaire o Click OK to continue
Select Luminaire window opens o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
o
o
25
Select Luminaire window opens You can determine the luminaire type to be used in the project. Click OK to continue
Select Luminaire window opens o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
26
Pick current beam pattern window opens o Click OK to continue and complete this process
Floodlight Method - Placement The Floodlight Method by placement enables You to define the position of the floodlight luminaire within a project.
Select Locate floodlight button from the menu
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
27
Click on the Target Grid where the use would like to place the mounting l ocation
The highlighted area on this page is reminding You that they must now specify the mounting height of the luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
28
Right click on the Target Grid to complete placing the mounting location
Shown above in this illustration indicates to You where the mounting point is situated on the target grid.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
29
Select Aim cu rr ent f lo od li gh t button from the toolbar to stipulate where the luminaire is to direct the light output
Left click on the mounting point to begin the process in aiming the luminaire light output
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
30
The “Z” coordinate refers to the aiming point to which the floodlight will be aiming at. In this case the aiming point was left at zero as the floodlight is to be mounted at 10 metres above the ground aiming down at the ground, for example to light a walkway.
Chalmlite for Windows ‘Z’ coordinate window opens o Enter the aiming point
You can now determine to which angle the aim of the floodlight, by clicking on the target grid. Left click on the Target Grid to determine the aiming angle of the luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
Left click to confirm all the aiming points on the target grid for the luminaire Right click to complete positioning the aiming points Right click once more to complete this process
Shown above as are the two aiming angles created in an earlier procedure
Chalmit Lighting
31
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
32
Luminaire Control & Zoom
The Target Grid above shows lux levels in this project – lux is the term used for the level of light distributed The minimum lux value are shown in cyan The maximum lux value are shown in red
Selecting the ‘Turn luminaire range off’ button, You will notice the values change automatically as the luminaires are turned off
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
33
As shown above by You selecting the ‘Turn luminaire range off’ button, the lux values have reduced greatly as shown by the increase of cyan points on the target grid
Selecting the ‘Turn luminaire range on’ button, You will be able to alter the lux l evels once again by individually selecting a luminaire.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
34
Left click the appropriate luminaire you wish to turn back on
By individually selecting one of the luminaires to be turned back on again You has altered the lux l evels
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
Selecting the ‘Turn one floodlight off’ button, You will be able to alter the lux levels automatically
Left click one of the aiming points from the floodlight to reduce the lux levels
Chalmit Lighting
35
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
36
You can easily zoom in and out of any particular area on the grid by using the mouse wheel, alternatively You can use the view menu from the toolbar
Select View menu from the toolbar Zoom Window o
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
37
Define the screen Left click on the lower left hand corner of the screen
Define the screen Left click again on the upper right hand corner to define the screen
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
The screen definition is shown here in a green outline
Shown here is the area defined in the previous step o The ‘10’ signifies the mounting height of the luminaire, this is not part of the Target Grid
Chalmit Lighting
38
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Exterior Tutorial
39
Select the View menu from the toolbar o Select Zoom Previous to return to the original screen view , with the complete target grid visible
You has now completed the Exterior lighting design scheme section of this tutorial.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
40
My First Room
You can create a new project by clicking the Projects button.
Opening an existing project. o File o Open
Chalmit Lighting
January 2009 Revision 1
Chalmlite V4.04 : Getting Started – Interior Tutorial
Load Data window opens o Select your chosen project
Select Setup menu from the toolbar to modify your project settings o Setup o Project Settings
Chalmit Lighting
41
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
42
New Project Settings - You must rename the project and choose the file directory to save this project to. o Enter new FILENAME o Enter new PROJECT NAME (if applicable) o Enter new SITENAME (if applicable) o Enter new ENGINEER (if applicable)
The program offers two methods for defining rooms. This tutorial will demonstrate both.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
43
Select Interior menu from the toolbar to define the Interior Parameters o Interior o Define Room
3.0
Define/edit ro om window opens o Simple, rectangular rooms can be quickly defined using the Rectangular roo m option o Edit the default lengths 1,3 and 2,4 as necessary o Edit room name to suit o The program automatically created a horizontal Target Grid in the room. The grid spacing (x and y) and grid height can be edited to suit o Edit the ceiling height as necessary
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
44
Office
3.0
Define/edit ro om window It’s important to click on the other length field after editing a length, otherwise the change will not hold. o Edit length, o Left-click on the other length field, otherwise the change will not hold.
3.0
Define/edit ro om window o Edit the default reflectance value of the ceiling, wall and floor to suit. If desired, a vertical grid can be placed on the wall by checking the appropriate “Grid” box. o When all necessary edits are complete, click OK
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
45
Position Room o Click Yes, the program will position the bottom-left corner of the room at (0,0) o Click No, the use can manually position the program of the bottom left corner of the room to suit.
Position Room o Click Yes, the program will position the bottom-left corner of the room at (0,0) o Click No, the use can manually position the program of the bottom left corner of the room to suit. o Left-click where you wish to position the bottom-left corner of the room o The program will prompt you to “ Specify (x, y) location for luminaire(s)” o If you do not wish to proceed to locate luminaires in the room at this point, simply right-click to finish
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
46
After the room is positioned, the lux levels on the exterior Target Grid (Grid 1) are recalculated.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
47
Lighting the room & Reflections
Define a luminaire using the program’s Icon method
Select Luminaires menu from the toolbar o Icon method o Define luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Define current luminaire icon window opens o You can click the icon to be used to signify the luminaire.
Define current luminaire icon window o Click on preferred icon o Click Choose luminaire button
Chalmit Lighting
48
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
49
Select Luminaire window opens o You can select the correct category to choose their luminaire o Click OK to continue
Select Lum inaire window o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
50
Select Luminaire window o You can determine the luminaire type to be used in the project. o Click OK to continue
Select Luminaire window o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
51
Select Luminaire window o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue
Define current luminaire icon window opens o Click Edit current description
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 V4.04 : Getting Started – Interior Tutorial
Define current luminaire icon window o Set Set l uminaire p arameters arameters window opens Here You can determine the mounting height, tilt, etc o Click OK to OK to continue
Define current luminaire icon window o Edit the Icon scale factor factor to illustrate a more more accurate accurate scale on screen screen o Click OK to OK to save and close this window
Chalmit Lighting
52
March 2010 Revision 2
Chalmlite V4.04 V4.04 : Getting Started – Interior Tutorial
53
Sometimes it is a good idea to zoom zoom in closer in the room room before beginning to locate the current luminare.
Select View menu View menu from the toolbar o Zoom Window Follow the program program prompts in the lower-left lower-left bar of the screen to click the the first, then second corners of the zoom window.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 V4.04 : Getting Started – Interior Tutorial
54
Use the shortcut button on the toolbar to Locate luminare(s)
Right click to complete locating luminaires Before turning on the room reflectance calculations, it is sometimes best to disable any external Target Grids in order to speed up the calculation process
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 V4.04 : Getting Started – Interior Tutorial
Click the Show/hide grid statistics window to open o This displays Target Grids in the project and their lux level statistics
Uncheck the Vis (visible) box to disable a Target Grid
Chalmit Lighting
55
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
56
Before turning on the room reflectance calculations, note the statistics of the grid in the room (Grid 2) o Click the Show/hide grid statistics window button to hide the window
Select Room calcs menu from the toolbar o Select Medium
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
57
Select Show/hide grid statistics window button to view how the lux level statistics in the room have changed o Click the button again to hide the Grid Details window
With every change made, such a moving a luminaire to another location, the program will automatically recalculate the lux levels. Therefore, it is good practice to turn the room reflectance calculations off until needed.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
58
Select Room calcs menu from the toolbar o Select Off
For basic rectangular rooms, the Interior Estimator feature can be used to quickly determine luminaire quantities for a given average lux level.
To access this feature when in a Project, click on the Launch Interior Estimator shortcut button. Alternatively, select the Help menu and click Show front screen.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
59
Predefined room shapes
Standard room shapes can be also be defined, i.e. L-shaped, C-shaped and T-shaped. The default length of each side of the shape can be edited.
Select View menu from the toolbar o Zoom All
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Select Interior menu from the toolbar o Define room
Select Standard shaped room button Choose a pre-defined room shape
Chalmit Lighting
60
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
61
Choose “ C-shaped (missing on E sid e)” and edit the lengths of sides 4 and 6
You should change the Room name to suit If no edits have been made and the default settings are suitable, click OK to exit the Define/edit roo m window
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
62
Position room o To join the bottom-left corner of the new room on to a corner of the existing room, click Yes.
Left click near to the appropriate corner of the existing room.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
63
Right-click to complete positioning the room.
Drawing ro oms & Ceilings
There is a second method to define a room. The Draw room method allows you to manually draw basic room shapes by left clicking on the screen to locate the corners of the room.
Select Interior menu from the toolbar o Draw room.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Left click to locate the first corner of your room
Define/edit ro om window opens
Chalmit Lighting
64
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
65
Define/edit ro om window o Select the Ceiling is non-flat radio button o Click the Edit ceiling profile button to edit
Edit Ceiling window opens o The profile of a roof/ceiling can be adjusted. A single apex, three points are required o The direction of the apex can be set parallel to the x-axis (east-west) or the y-axis (north south)
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Edit Ceiling window o The height (Z value) of the three points can be adjusted to suit o Click OK when satisfied with the s ettings.
Click OK to leave the Define/edit room window
Chalmit Lighting
66
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
The direction of the apex is shown parallel to the x-axis as desired.
Select Interior menu from the toolbar o Edit room o Move room
Chalmit Lighting
67
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Select room to edit window opens Select the room you wish to move and click OK
Left click to position the bottom-left corner of the room
Chalmit Lighting
68
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
69
Emergency Luminaires
Emergency luminaires, i.e. with internal battery back-up, can be d efined and quickly switched between emergency and mains mode operation by using shortcut buttons. Select Luminaires menu from the toolbar o Icon method o Define luminaire
Select a different icon from that used for the normal (non-emergency) luminaire
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Define current luminaire window opens o You can click the icon to be used to signify the luminaire.
Select Luminaire window opens o You can select the correct category to choose their luminaire o Click OK to continue
Chalmit Lighting
70
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
71
Select Luminaire window o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue
Select Lum inaire window o You can determine the luminaire type to be used in the project. All Emergency luminaires are stored within the ‘Emergency’ category. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
72
Select Luminaire window opens o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue
Select Luminaire window opens o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
73
Define current luminaire icon window opens o Click Edit current description if the default height, maintenance factor, etc need to be changed. o Click OK to leave the Define current luminaire icon window. Important note – when an emergency luminaire is defined, it is operating in emergency mode.
Now that an emergency luminaire is defined, some of the previously located normal (non-emergency) luminaires can be changed to emergency versions.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Select Lum inaires menu from the toolbar o Select Icon method o Select Change one luminaire menu item
Define current luminaire icon window opens o Ensure that the icon defined as emergency luminiare is highlighted o Click OK to continue
Chalmit Lighting
74
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Any number of luminaire icons can be changed by left clicking on each.
Right-click to finish changing luminaire icons
Chalmit Lighting
75
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
76
To view the lux levels achieved from the emergency luminaires only, the normal luminaire can be turned off.
Click the Turn luminaire range off button.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
Click on any one of the normal (non-emergency) luminaire icons to turn off the range.
To view a summary of the emergency lux levels o Click the Show/hide grid statistics window button.
Chalmit Lighting
77
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
78
The Grid Details window displays a summary of the lux levels for each Target Grid i.e. minimum, average, uniformity (min/ave) and maximum. o Click the button again to close the window.
To view the lux levels achieved with the normal luminaires turned on and the emergency luminaires turned to mains mode operation, the buttons on the right side of the screen are used.
Chalmit Lighting
March 2010 Revision 2
Chalmlite V4.04 : Getting Started – Interior Tutorial
79
Click the ‘Turn luminaire range on’ button and left-click on any one of the normal (non-emergency luminaire icons.
Click the ‘Turn luminaire range on’ to mains mode button.
Chalmit Lighting
March 2010 Revision 2