ALARM REFERENCE GUIDE
Alcatel 1678MCC Rel. 3.2
METRO CORE CONNECT
1
3AG 24197 ACAA - Ed. 04
3AG 24197 ACAA – Ed. 04
Table of Contents
1
2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1.1
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1.2
Purpose of the Handbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1.3
Target Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
1.4
Handbook Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
1.5
Product Release Handbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1.6
Safety Norms and Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1.7
General on Alcatel Customer Documentation . . . . . . . . . . . . . . . . . .
4
1.8
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.9
Registered Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.10 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.11 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.12 Handbook Change History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Preview to Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
2.1
Current Alarms Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
2.2
Alarm Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
2.3
Alarm Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
2.3.1
Perceived Severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
2.3.2
Event Date & Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
2.3.3
Friendly Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
2.3.4
Event Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
2.3.5
Probable Cause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
2.3.6
Reservation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
2.3.7
Clearing Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
2.3.8
Acknowledgement Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
2.3.9
Correlated Notification Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
2.3.10 Repetition Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
3AG 24197 ACAA - Ed. 04
I
2.4
2.5
Alarm Severity Assignment Profile (ASAP) . . . . . . . . . . . . . . . . . . . . . .
14
2.4.1
DefaultĆ and FreeĆuse ASAPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
2.4.2
Service Dependency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
2.4.3
Severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
2.4.4
Contents of Predefined ASAPs on the 1678MCC . . . . . . . . . . . . . . . . . . . . .
17
Mapping Tables: TP Names on Craft Terminal . . . . . . . . . . . . . . . . . .
20
3
Correlation Element Type - Event Type . . . . . . . . . . . . . . . . . . . . . . . . . .
23
4
Equipment Alarms/Processing Error Alarms . . . . . . . . . . . . . . . . . . . . . .
33
4.1
Battery Failure (BF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
4.2
Communications Subsystem Failure (CSF) . . . . . . . . . . . . . . . . . . . . . .
37
4.3
Fuse Failure (FF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
4.4
High Temperature (HT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44
4.5
Internal Communication Problem (ICP) . . . . . . . . . . . . . . . . . . . . . . . .
47
4.6
Input Power Loss (IPL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
4.7
LAN Failure (LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
4.8
No RTC Synchronization (NRTCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
54
4.9
Optical Connector Cover Open (OCCO) . . . . . . . . . . . . . . . . . . . . . .
55
4.10 Pump Failure (PF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56
4.11 Resource Isolation (Q3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
57
4.12 Redundant Clock Fail A/B (RCFA/B) . . . . . . . . . . . . . . . . . . . . . . . . . . .
58
4.13 Redundant Matrix A/B Failure (RMFA/B) . . . . . . . . . . . . . . . . . . . . . . .
60
4.14 Replaceable Unit Missing (RUM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
62
4.15 Replaceable Unit Problem (RUP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
4.16 Replaceable Unit Type Mismatch (RUTM) . . . . . . . . . . . . . . . . . . . . . . .
83
4.17 Software Download Failure (SDF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
84
4.18 Software Environment Problem (SEP) . . . . . . . . . . . . . . . . . . . . . . . . . .
86
4.19 Timing Problem (TIP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
87
II
3AG 24197 ACAA - Ed. 04
5
6
Communications Alarms/ Processing Error Alarms . . . . . . . . . . . . . . . .
89
5.1
Abstract . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
89
5.2
Alarm Indication Signal (AIS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
90
5.3
Communication Protocol Error (CPE) . . . . . . . . . . . . . . . . . . . . . . . . . .
95
5.4
Communications Subsystem Failure (CSF) . . . . . . . . . . . . . . . . . . . . . .
97
5.5
Degraded Signal (DS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
98
5.6
Loss of Alignment (LOA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
103
5.7
Loss of Frame (LOF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
104
5.8
Loss of MultiFrame (LOMF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
106
5.9
Loss of Pointer (LOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
108
5.10 Loss of Signal (LOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
111
5.11 Payload Type Mismatch (PLTM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
115
5.12 Remote Defect Indication (RDI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
118
5.13 Sequence (Number) Mismatch (SQM) . . . . . . . . . . . . . . . . . . . . . . . . .
123
5.14 Server Signal Fail (SSF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
124
5.15 Trace Identifier Mismatch (TIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
129
5.16 Transmitter Degraded (TD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
133
5.17 Transmitter Failure (TF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
134
5.18 Unavailable Time (UAT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
135
5.19 Underlying Resource Unavailable (URU) . . . . . . . . . . . . . . . . . . . . . . .
138
5.20 Unequipped (U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
139
Quality of Service Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
145
3AG 24197 ACAA - Ed. 04
III
1
Introduction
1.1
General Information
WARNING Strict compliance with the instructions and procedures speĆ cified in the product documentation (see product release note for the complete list of applicable manuals) is the preĆ condition of the enforceability of such warranty claims against Alcatel. Warranty claims which result from nonĆcompliance with the defined procedures, cannot be enforced against Alcatel.
NOTICE
COPYRIGHT NOTIFICATION
The product specification and/or performance levels conĆ tained in this document are for information purposes only and are subject to change without notice. They do not repreĆ sent any obligation on the part of ALCATEL. The technical information of this manual is the property of ALCATEL and must not be copied, reproduced or disclosed to a third party without written consent.
1.2
Purpose of the Handbook This handbook refers to the Multiband Multiservice Connect Alcatel 1678 Metro Core Connect (1678MCC) which belongs to the Alcatel Intelligent Optical Networks (ION) product family. In general the system is referred to as 1678MCC or NE (Network Element) only. The aim of this handbook is to list all alarms coming from the 1678MCC and being indicated by the Alarm Manager. For each alarm the possible causes, its effects on service and the ways to get out of the alarm situation are described. The use of this handbook is indicated in the list of the "Handbooks related to the specific software application", in the Technical and Operator's Handbook of the Network Element.
3AG 24197 ACAA - Ed. 04
1
Being the document dedicated to a set of equipment, screens are inserted as "example" and can be extracted from any of the referred equipment. This handbook must be used together with the associated Technical and Operator's Handbooks and does not repliĆ cate information contained into them. In particular, all cautions relevant to safety, rules for EMC and ESD, as well as warnings regarding operations that may cause damages to the equipment, are not duplicated here, but must be retrieved from the Technical Handbook. When using this handbook it is assumed that the Operators knows:
1.3
-
the structure (hardware composition) and all the possible operating modes of the equipment (productĆrelease) this handbook refers to.
-
how to use the Craft Terminal (CT)
-
how to use the dialog of the Alarm Surveillance component (refer to 1330AS Rel 6.5 Operator's Handbook", 3AG 88876 AAAA)
Target Audience This handbook is intended for operator's concerned with managing the 1678MCC.
1.4
Handbook Structure This handbook is divided into the following main topics as described in the table of contents:
2
-
Introduction containing general information about structure and use of the handbook, and safety norms on using the equipments.
-
Preview to Alarms providing general information on alarms and alarm handling
-
Correlation Element Type - Event Type providing an overview on which alarm (i.e. event
3AG 24197 ACAA - Ed. 04
type) is possibly reported for which board or Termination Point (i.e. element type)
1.5
-
Equipment Alarms / Processing Error Alarms describing for each Equipment alarm the possible causes, the effects on service and the ways to get out of the alarm situation
-
Communications Alarms / Processing Error Alarms describing for each Communications alarm the possible causes, the effects on service and the ways to get out of the alarm situation
-
Quality of Service Alarms describing for each Quality of Service alarm the possible causes, the effects on service and the ways to get out of the alarm situation
Product Release Handbooks Refer to the Technical Handbook for a list of the comĆ plete set of Customer Documentation.
1.6
Safety Norms and Labels Refer to the Safety Instructions, 3AG 24198 AAAA, to obtain the following information:
3AG 24197 ACAA - Ed. 04
-
FIRST AID FOR ELECTRIC SHOCK
-
COMPLIANCE WITH EUROPEAN NORMS.
-
SAFETY RULES D
General rules
D
Harmful optical signals
D
Risk of explosion
D
Moving mechanical parts
D
Heat-radiating Mechanical Parts
-
ELECTROMAGNETIC COMPATIBILITY
-
ELECTROSTATIC DISCHARGERS (ESD)
-
EQUIPMENT LABELS
3
1.7
General on Alcatel Customer Documentation Refer to the Technical Handbook to obtain the following information:
1.8
-
Definition of the terms Product, Product Release and Version
-
Handbook supply to Customers
-
Aims of standard Customer Documentation
-
Handbook Updating
-
Customer Documentation supply on CD-ROM
Symbols This handbook uses the following symbol: This symbol is used to emphasize particularly important inĆ formation.
1.9
Registered Trademarks Refer to the Technical Handbook for a list of registered trademarks.
1.10
Service Information In case of problems with the 1678MCC, please contact your Customer Support Center for information.
1.11
Terminology Refer to the Basic Operator's Handbook for abbreviaĆ tions and glossary.
4
3AG 24197 ACAA - Ed. 04
1.12
Handbook Change History Ed. 04: Ed.04 created in October, 2006 for product release 3.2P3. The main updates since Ed. 03 are: -
editorial corrections (e.g. "NAU"->"FLC")
Ed. 03: Ed.03 created in August, 2006 for product release 3.2P3. The main updates since Ed. 02 are: -
SLSks41964: DTAG: wrong description of FF
-
Corrected references to replacement procedures
-
Replaced Customer Support Center by TAC.
Ed. 02: Ed.02 created in December, 2005 for product release 3.2P1. The main updates since Rel. 3.2 are: -
Added alarms for new equiment of Rel. 3.2
-
Updated GBE alarms to current status
-
Added LOS and AIS alarms for sPPI port (for SONET T6)
-
SLSks37647: ARG, CTOpHB: Description of Supervisory Unequipped has to be adapted
-
SLSks36196: NI: Rest.is not MS-SSF trig.if 1670 is used (man_action)
Ed. 01: Ed.01 created in July, 2005 for product release 3.2.
3AG 24197 ACAA - Ed. 04
5
6
3AG 24197 ACAA - Ed. 04
2
Preview to Alarms For the Alarm Management the Alarm Surveillance (AS), which is a generic component of the ALMAP product, is used. A complete user guide of the AS can be found in the 1330AS Rel. 6.5 Operator's Handbook", which is also available as online help. To open the online help use the Help" menu of the AS dialogs. In this chapter only a short overview of the main functionalĆ ity of the Alarm Management is provided.
2.1
Current Alarms Management When an alarm is raised by a resource (or by a neighboring one) detecting a fault, it is received by the Alarm SurveilĆ lance which stores it and warns the operator by ringing a bell or by the appearance of a specific icon on the screen. The alarm may be displayed as soon as it is signalled accordĆ ing to the operator needs. During the whole period an alarm is considered to be current (CLR or NCLR), its state is permanently realĆtime refreshed so that any operator who displays the alarm is informed if it has been reserved or not, if it has been acknowledged or not, if a trouble ticket has been requested for this alarm or not. The alarm is cleared by the emitting resource as soon as the problem is no longer present at the resource. Then the alarm is no longer considered as a current alarm and as soon as it is acknowledged by the operator it disappears from the current alarm set and is archived to the set of historical alarms. Deleted alarms also disappear from the sublist (or Main List) and are archived, if matching the archiving filter. However, the problem to which the alarm is linked may not be solved immediately. In such a case the alarm is repeated after a while until the problem is solved. Alarm Surveillance associates a repetition counter to each received alarm. Furthermore, if the alarm is not cleared at all by the reĆ source which raised it before for any reason, the Alarm SurĆ veillance offers the possibility to archive it manually on the operator's request.
3AG 24197 ACAA - Ed. 04
7
2.2
Alarm Counter Available global information is displayed by counters that show the number of alarms of a single severity level as well as the total number of alarms in the sublist, and the number of non acknowledged and cleared alarms. These counters may be realĆtime refreshed (when the sublist is active) or not (when the sublist is inactive). After confirming unacknowledged alarms, the alarm counter are changed as follows: -
NACK" is decreased according to the number of confirmed alarms
-
ACK" is increased according to the number of confirmed alarms
Clear" is increased as soon as an alarm is cleared.
Figure 1
8
Example of Sublist Displaying Unacknowledged Alarms
3AG 24197 ACAA - Ed. 04
Because of the overwrite behavior in the alarm lists (autoĆ matic deletion of old alarms by the system in order to create new memory capacity) or after manual deletion of alarms by the operator, an existing alarm correlation may not be visible anymore, i.e. the begin alarm is deleted, but the corĆ responding end alarm is still part of the unacknowledged alarm list.
3AG 24197 ACAA - Ed. 04
9
2.3
Alarm Information Alarms or Alarm notifications consist in messages emitted by resources that have detected problems or failures. Information contained in the alarm includes -
information that identifies the resource which has raised the alarm
-
information that identifies the type of the problem the alarm refers to.
Note that these pieces of information are mandatory in any alarm notification, as well as the date and time the alarm has been raised by the resource. Other optional information such as the specific problems the alarm is linked to, the notiĆ fication identifier, etc., may also be present to help the operator in the alarm management process. The operator can create alarm sublists accustomed to his/ her preferences, including filtering and display of alarm inĆ formation. For more information about alarm management and alarm (subĆ)lists refer to the 1330 AS Rel. 6.5 OperaĆ tor's Handbook. To obtain more information about the element that has reĆ ported the alarm, it is possible to navigate to this element: -
Mark the alarm in the alarm list and select External Application Ć> emlusm" of the Navigation" menu.
Depending on the Event Type the Equipment or TransmisĆ sion View is opened and the affected element is selected (i.e. framed in orange). In these Views you can also access the Alarm Reference Guide (this handbook) as online description:
10
-
Select Tutorial" from the Help" menu.
-
A confirmation box appears asking whether or not to open Netscape. Confirm to open Netscape.
-
When the Netscape window has opened, click on the link Alarm Reference Guide" to navigate to the table of contents. From there you can navigate to the alarm for which you want detailed information.
3AG 24197 ACAA - Ed. 04
2.3.1
Perceived Severity The entry Perceived Severity indicates the severity level of the problem when the alarm is raised. Malfunctions are ranked into five severity levels:
2.3.2
-
Critical, when it is no longer possible to provide the service requested by the user, e.g. it is applied for "server" boards in cases where more than one "client" board is affected by this failure (due to an underlying serverĆclient relationship).
-
Major,
-
Minor,
-
Warning, which means no impact is reported upon the quality of service offered to the user,
-
Indeterminate, if the severity level cannot be defined by the resource which raises the alarm. (Possible reason are incorrect ASAP settings.)
-
Cleared, if the alarm is cleared by the resource which has raised it before.
Event Date & Time This entry indicates date and time when the alarm was raised on the resource. The data is displayed as YYYY/MM/DD hh:mm:ss E.g. 2004/05/20 06:29:24 indicates an alarm that was risen at 29 minutes and 24 seconds past six o'clock in the morning, on the 20th of may 2004.
3AG 24197 ACAA - Ed. 04
11
2.3.3
Friendly Name With the help of the friendly name it is possible to locate the element that has reported the alarm. The friendly name includes information about the NE and the location of the element where the alarm was risen. DeĆ pending on the alarm's event type, the element type can be a board or a TP. For equipment alarms the location is givĆ en down to board level. Communication and quality of serĆ vice alarms include a further entry identifying the port and the TP. Quality of service alarms also provides an alarm type giving threshold crossing information. The general format of the friendly name equals NE/rack#subrack#slot#/port#ĆTP If we take the marked entry from Figure 1 as an example: Anlage84/r01sr2sl16/port#01ĆElRsCTP indicates an alarm raised by ElRsCTP on port 1 of the board on slot 16 in subrack 2 of rack 1of NE Anlage 84".
2.3.4
Event Type The entry Event Type" indicates the alarm type taken out of the following ones: -
Quality of Service
-
Communications
-
Processing Error
-
Equipment
-
Environmental Alarms
Hardware or control system errors are reasons for an Equipment alarm, Environmental alarm or ProcessĆ ing Error alarm. Transmission errors are the reason for Communication alarms. Threshold problems are the reason for Quality of Service alarms.
2.3.5
Probable Cause The probable cause indicates the error reason (e.g. Loss of Frame).
12
3AG 24197 ACAA - Ed. 04
2.3.6
Reservation Status The operator can reserve a current alarm to make sure to be the only responsible for this alarm. In this case the reservation status of the selected alarm changes from NRSV (non reserved) to RSV (reserved). An alarm can only be unreserved by the operator who has reserved it before.
2.3.7
Clearing Status A current alarm that has not been solved is indicated as NCLR (not cleared). As soon as the problem is no longer present at the resource, its status changes to CLR (cleared).
2.3.8
Acknowledgement Status Unacknowledged alarms are marked NACK in the list and can be confirmed by the operator. The statuses of the seĆ lected alarms change, passing from NACK (non acknowlĆ edged) to ACK (acknowledged). Note that acknowledging a cleared alarm is an implicit archiving action. Thus, the acknowledgement actually archives the alarm and causes its disappearance from the current alarm list.
2.3.9
Correlated Notification Flag If a correlation notification is sent together with the reĆ ported alarm, this flag will be set to YES.
2.3.10 Repetition Counter The repetition counter indicates the number of times an alarm was sent by a resource.
3AG 24197 ACAA - Ed. 04
13
2.4
Alarm Severity Assignment Profile (ASAP) An ASAP is a list containing probable alarm causes to which severities are assigned according to their service dependenĆ cy. Alarms are indicated at the CT according to the assigned ASAP, displaying the assigned severity, or are not indicated at all. I.e. the ASAP is used as an alarm filter.
2.4.1
DefaultĆ and FreeĆuse ASAPs There are two types of ASAPs: -
the predefined default ASAPs which include all potential probable causes/severities raised by the NE. These ASAPs are defined as readĆonly, i.e. it is not possible to modify their contents and it is not possible to remove them.
-
the user defined ASAP created by the user. A user defined ASAP can also be removed by the managing system. The number of severities and of probable causes is fixed. Their characteristics cannot be modified. The ASAP function only enables the modification of the seĆ verities assigned to the probable causes, it does not alĆ low the addition, removal or modification of the probĆ able causes themselves.
The following five ASAPs are configured as default ASAPs: -
14
ASAP: No Alarms This ASAP inhibits the alarm indication. This is the default ASAP for D
PPITTP
D
VCĆ4 TTP, VCĆ12 TTP
D
E4 CTP, E1 CTP,
D
AUĆ4 CTP and concatenated, AUĆ3 CTP
D
PTC
D
VCĆ4XV TTP, VCĆ3XV TTP
3AG 24197 ACAA - Ed. 04
D -
2.4.2
VC-4V TTP, VC-3V TTP
ASAP: Primary Alarms This ASAP enables the indication of all primary communication alarms (AIS, SSF and RDI are disabled) and equipment alarms. This is the default ASAP for D
equipment alarms
D
ESTTP, OSTTP
D
RSTTP
D
GMAUTTP
D
P4CTP, P12 CTP
D
TrailMonitor (POM)
D
SupervisoryUnequippedMonitor (SUT)
D
UAT Alarms
-
ASAP: No Remote Alarms This ASAP enables the indication of all primary communication alarms plus SSF (AIS and RDI are disabled) and equipment alarms.
-
ASAP: All Alarms This ASAP enables the indication of all alarms. This is the default ASAP for MSTTP.
-
ASAP: No Server Alarms This ASAP enables the indication of all alarms except SSF, Redundant Clock Fail A/B and Redundant Matrix A/B Failure.
Service Dependency Depending on its effect on service, each probable cause can be assigned an alarm severity in the ASAP. This is called serĆ vice dependency. There are three service dependency types:
3AG 24197 ACAA - Ed. 04
-
Service Affecting
-
Non Service Affecting
-
Service Independent.
15
Some restrictions apply to the assignment of a severity to service dependency. Table 1 lists all the different allowed cases of severity assignment and service dependency. Case
Service Affecting
Non Service Affecting
Service Independent
1
critical or major
minor or warning or nonĆ alarmed
not used
2
critical or major
not used
not used
3
not used
minor or warning or nonĆ alarmed
not used
4
not used
not used
critical or major or minor or warning or nonĆ alarmed
Table 1
Permissible Assignment of Service Dependency and Severity Note, that the 1678MCC handles the service dependency types service affecting" and non service affecting" only in respect of Replaceable Unit Missing (RUM) alarms (plug out of a board). All other alarms are handled with severity type service independent". This means that when cloning an ASAP, cases 1 to 3 of Table 1 can only be applied to RUM alarms (it is recommended to use Case 1 if RUM should apĆ pear as alarm and Case 3 if RUM should not appear as alarm). All other alarms should be configured according to Case 4.
2.4.3
Severity Objects (TPs and Equipment) emitting alarms reference to default ASAPs with exception of the following cases: -
16
Whenever an object cannot evaluate the ASAP, e.g. due to a wrong provisioning of the manager, the alarm is emitted with the severity indeterminate".
3AG 24197 ACAA - Ed. 04
2.4.4
Contents of Predefined ASAPs on the 1678MCC The 1678MCC handles the service dependency types serĆ vice affecting" (SA) and non service affecting" (NSA) only for replaceable unit missing (RUM) alarms (plug out of a board). All other alarms are handled with severity type service independent". Therefore, in the following tables, SA and NSA severity dependency is only mentioned for this alarm.
ASAP No Alarms Primary Alarms
No Remote Alarms
All Alarms No Server Alarm
Battery Failure
NAL
MIN
MIN
MIN
MIN
Fuse Failure
NAL
MIN
MIN
MIN
MIN
High Temperature
NAL
MAJ
MAJ
MAJ
MAJ
Input Power Loss
NAL
MAJ
MAJ
MAJ
MAJ
Internal Communication Problem
NAL
WAR
WAR
WAR
WAR
Lan Alarm
NAL
MIN
MIN
MIN
MIN
No RTC Synchronization
NAL
MIN
MIN
MIN
MIN
Optical Connector Cover Open
NAL
MAJ
MAJ
MAJ
MAJ
Pump Failure
NAL
MIN
MIN
MIN
MIN
Redundant Clock Fail A
NAL
MIN
MIN
MIN
MIN
Redundant Clock Fail B
NAL
MIN
MIN
MIN
MIN
Redundant Matrix A Failure
NAL
MIN
MIN
MIN
MIN
Redundant Matrix B Failure
NAL
MIN
MIN
MIN
MIN
Replaceable Unit Missing (SA)
NAL
MAJ
MAJ
MAJ
MAJ
Replaceable Unit Missing (NSA)
NAL
MIN
MIN
MIN
MIN
Replaceable Unit Problem
NAL
MAJ
MAJ
MAJ
MAJ
Replaceable Unit Type Mismatch
NAL
WAR
WAR
WAR
WAR
Synchronization Source Mismatch
NAL
MIN
MIN
MIN
MIN
Temperature Out Of Range
NAL
MIN
MIN
MIN
MIN
Probable Cause
3AG 24197 ACAA - Ed. 04
17
No Alarms Primary Alarms
No Remote Alarms
All Alarms
No Server Alarm
Timing Problem
NAL
MAJ
MAJ
MAJ
MAJ
Unconfigured Equipment Present
NAL
WAR
WAR
WAR
WAR
Probable Cause
Table 2
Equipment Alarms
ASAP No Alarms Primary Alarms
No Remote Alarms
All Alarms No Server Alarms
Alarm Indication Signal
NAL
NAL
NAL
MAJ
MAJ
Communications Subsystem Failure
NAL
MAJ
MAJ
MAJ
MAJ
Communications Protocol Error
NAL
MAJ
MAJ
MAJ
MAJ
Degraded Signal
NAL
MIN
MIN
MIN
MIN
Loss Of Alignment
NAL
MAJ
MAJ
MAJ
MAJ
Loss Of Frame
NAL
MAJ
MAJ
MAJ
MAJ
Loss Of Multiframe
NAL
MAJ
MAJ
MAJ
MAJ
Loss Of Pointer
NAL
MAJ
MAJ
MAJ
MAJ
Loss Of Signal
NAL
MAJ
MAJ
MAJ
MAJ
Payload Type Mismatch
NAL
MAJ
MAJ
MAJ
MAJ
Remote Defect Indication
NAL
NAL
NAL
WAR
WAR
Sequence Mismatch
NAL
MAJ
MAJ
MAJ
MAJ
Server Signal Failure
NAL
NAL
MAJ
MAJ
NAL
Trace Identifier Mismatch J0
NAL
MAJ
MAJ
MAJ
MAJ
Trace Identifier Mismatch J1–J2 NAL
MAJ
MAJ
MAJ
MAJ
Transmitter Degraded
NAL
WAR
WAR
WAR
WAR
Transmitter Failure
NAL
MAJ
MAJ
MAJ
MAJ
Unavailable
NAL
MAJ
MAJ
MAJ
MAJ
Underlying Resource Unavailable
NAL
MAJ
MAJ
MAJ
MAJ
Unequipped
NAL
MAJ
MAJ
MAJ
MAJ
frequencyOffset
NAL
MIN
MIN
MIN
MIN
lossOfTimingSources
NAL
MIN
MIN
MIN
MIN
Probable Cause
Table 3
18
Communication Alarms
3AG 24197 ACAA - Ed. 04
ASAP No Alarms Primary Alarms
No Remote Alarms
All Alarms No Server Alarms
Sfwr Download Failure
NAL
MIN
MIN
MIN
MIN
Sfwr Environment Problem
NAL
WAR
WAR
WAR
WAR
Probable Cause
Table 4
Processing Error Alarms
The following abbreviations are used in the tables: CRI
CRItical
MAJ
MAJor
MIN
MINor
NAL
Non ALarmed
NSA
Non Service Affecting
SA
Service Affecting
WAR
WARning
The probable cause families Quality Of Service and EnviĆ ronmental cannot be configured via ASAP. The only Quality Of Service probable cause is Threshold Crossed". The severities for Threshold Crossed can be conĆ figured via the PM Threshold Tables (see CT Operator's Handbook, Chapter “PM Threshold Table Create/Modification/Display”). The severities for Environmental probable causes can be configured in the Station Alarm Configuration dialog (see CT Operator's Handbook, Chapter “Configuration of Station Alarms”).
3AG 24197 ACAA - Ed. 04
19
2.5
Mapping Tables: TP Names on Craft Terminal The Termination Point (TP) names on the Craft Terminal (CT) reflect the object model the user interface is based on. Therefore they differ from the TP names given in the ITUĆT recommendations. The following tables lists the TP names mapping both conventions. Craft Terminal
ITUĆT
ElS
ESTTP
OpS
OSTTP
RST
RSTTP
MST
MSTTP
MSP
MSP
Au3P
AUĆ3 CTP
Au4P
AUĆ4 CTP
Au4P/4c
AUĆ4Ć4c CTP
Au4P/16c
AUĆ4Ć16c CTP
Au4P/64c
AUĆ4Ć64c CTP
ModVc4
VCĆ4 TTP
Tug3
TUGĆ3
Tug2
TUGĆ2
Tu3
TUĆ3 CTP
Tu12
TUĆ12 CTP
Table 5 Craft Terminal
ITUĆT
MAU
MAU
PTC
PTC
VC3XV
VCĆ3-Xv TTP
VC3V
VCĆ3V TTP
VC4XV
VCĆ4-Xv TTP
VC4V
VCĆ4V TTP
Table 6
20
SDH TPs
Gigabit Ethernet TPs
3AG 24197 ACAA - Ed. 04
Craft Terminal
ITUĆT
P
PPITTP
E4
E4 CTP
P4
P4 CTP
Vc4
VCĆ4 TTP
E1
E4 CTP
P12
P4 CTP
Vc12
VCĆ12 TTP
Table 7
3AG 24197 ACAA - Ed. 04
PDH TPs
21
22
3AG 24197 ACAA - Ed. 04
3
Correlation Element Type - Event Type The table below shows the Probable Causes for all boards of the 1678MCC. Each board is only listed once. For examĆ ple the board P4ES1 can be used within the 1670SM shelf as well as within the 1662MC shelf, it is only listed once (see Boards of 1670SM Shelf" below). Equipment Alarm / Processing Error Alarm Correlation Board Type - Probable Cause
Boards of 1678MCC Main Shelf: Matrix 640GBIT/S (MX640, MX640GA) Matrix 320GBIT/S (MX320, MX320GA) Matrix 160GBIT/S (MX160) Lower Order Adaptation/Matrix 40G(LAX40) Lower Order Adaptation/Matrix 20G(LAX20) FLCCONGI FLCSERV, FLCSERVA Power Supply/Filter (PSF) Termination Bus (BUSTERM) 16 x STM4/1 Port (P16S1S4) 16 x STM1 Port (P16S1S) 16 x STM16 Port (P16S16) 8 x STM16 Port (P8S16) 4 x STM16 Port (P4S16) STM-64 MSA Port (S64M) 2 x STM-64 MSA Port (P2S64M) 4 x STM-64 MSA Port (P4S64M) 4 x STM-64 XFP Port (P2S64X) 2 x STM-64 XFP Port (P4S64X) 1678MCC Fan Unit (FAN78) 16 x GE Port (P16GE) 8 x GE Port (P8GE) 4 x GE Port (P4GE) DC/DC Converter Step Up (NGTRCSU) Craft Terminal (CT) Boards of 1670SM Shelf: Control & General I/F HC (CONGIHC) Equipment Controller Card (EQUICO) Matrix HI-CAP (HCMATRIX) Termination Bus 1670 (BTERM) 1 x STM64 Link (S64MLINK) 4 x 140 Port (P4E4) 2 x 140 Adapter (A2E4)
3AG 24197 ACAA - Ed. 04
BF
CSF
FF
HT
ICP
IPL
LAN
NRTCS
OCCO
PF
Q3
–
X
X
X
X
–
X
–
–
–
–
–
X
X
X
X
–
X
–
–
–
–
–
X
X
X
X
–
X
–
–
–
–
–
X
X
X
X
–
X
–
–
–
–
–
X
X
X
X
–
X
–
–
–
–
–
–
X
X
X
–
X
X
–
–
–
–
–
X
X
X
–
X
X
–
–
–
X
–
X
–
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
X
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
X
–
X
–
–
–
–
–
–
–
–
–
X
–
–
–
–
X
–
–
–
–
–
X
–
–
X
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
23
4 x STM-1 Electrical Port (P4ES1) 4 x STM-1 Electrical (A4ES1) High Speed Protection (HPROT) 16 x STM-1 Opt/El Port (P16S1) 16 x STM–1 Electrical Access (A16ES1) 16 x High Speed Protection (HPROT16) 16 x STM-1 Optical Port Compact ( P16OS1) 12 x STM-1 Optical Access Compact (A12OS1) 4 x STM-4 Port (P4S4) 2 x STM-4 Access (A2S4) 1670SM FAN Unit (FANC) Boards of 1662MC Shelf: Control & General I/F HC (CONGI) Compact STM-16 (SYNTH16) Termination Bus 1662 (TBUS) 63 x 2Mbit/s Port (P63E1) 63 x 2Mbit/s Port with retiming (P63E1NM4) 63 x 2 Mbit/s Prot. (75 Ohm) (A63E1-4TE) 63 x 2 Mbit/s Prot. (120 Ohm) (A63E1-120) Low Speed Protection (LPROT) 1662SMC FAN Unit (FAN) Modules: L64.2 MSA Optical Interface (ML642) V64.2 MSA Optical Interface (MV642) U64.2 MSA Optical Interface (MU642) Equipment Controller 1662 (EQUICO62)
Table 8
BF
CSF
FF
HT
ICP
IPL
LAN
NRTCS
OCCO
PF
Q3
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
–
X
–
X
–
–
–
–
–
–
–
–
–
X
–
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
–
–
X
X
–
–
–
–
–
–
X
–
–
X
X
–
–
–
–
–
–
X
–
–
X
X
–
–
–
–
–
–
–
–
–
–
–
–
Equipment Alarms/Processing Error Alarms - 1
Legend of Table 8 and Table 9
24
BF
Battery Failure
CSF
Communication Subsystem Failure
FF
Fuse Failure
HT
High Temperature
ICP
Internal Communication Problem
IPL
Input Power Loss
LAN
LAN failure
NRTCS
No RTC Synchronization
3AG 24197 ACAA - Ed. 04
OCCO
Optical Connector Cover Open
PF
Pump Failure
Q3
Resource Isolation
RCFA
Redundant Clock Failure A
RCFB
Redundant Clock Failure B
RMAF
Redundant Matrix A Failure
RMBF
Redundant Matrix B Failure
RUM
Replaceable Unit Missing
RUP
Replaceable Unit Problem
RUTM
Replaceable Unit Type Mismatch
SDF
Software Download Failure
SEP
Software Environment Problem
TIP
Timing Problem
Equipment Alarm / Processing Error Alarm Correlation Board Type - Probable Cause (continued)
Boards of 1678MCC Main Shelf: Matrix 640GBIT/S (MX640, MX640GA) Matrix 320GBIT/S (MX320, MX320GA) Matrix 160GBIT/S (MX160) Lower Order Adaptation/Matrix 40G(LAX40) Lower Order Adaptation/Matrix 20G(LAX20) FLCCONGI FLCSERV, FLCSERVA Power Supply/Filter (PSF) Termination Bus (BUSTERM) 16 x STM4/1 Port (P16S1S4) 16 x STM1 Port (P16S1S) 16 x STM16 Port (P16S16) 8 x STM16 Port (P8S16) 4 x STM16 Port (P4S16) STM-64 MSA Port (S64M) 2 x STM-64 MSA Port (P2S64M)
3AG 24197 ACAA - Ed. 04
RCFA
RCFB
RMAF
RMBF
RUM a)
RUP
RUTM b)
SDF c)
SEP
TIP
–
–
X
X
X
X
X
X
–
–
–
–
X
X
X
X
X
X
–
–
–
–
X
X
X
X
X
X
–
–
–
–
–
–
X
X
X
X
–
–
–
–
–
–
X
X
X
X
–
–
–
–
–
–
X
X
X
X
X
–
–
–
–
–
X
X
X
X
X
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
25
RCFA
RCFB
RMAF
RMBF
RUM a)
RUP
RUTM b)
SDF c)
SEP
TIP
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
X
X
X
X
X
X
X
X
–
X
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
X
X
X
–
–
–
X
X
–
–
X
X
X
X
–
X
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
–
–
X
–
–
–
–
–
4 x STM-64 MSA Port (P4S64M) 4 x STM-64 XFP Port (P4S64X) 2 x STM-64 XFP Port (P2S64X) 1 x STM-64 XFP Port (S64X) 1678MCC Fan Unit (FAN78) 16 x GE Port (P16GE) 8 x GE Port (P8GE) 4 x GE Port (P4GE) DC/DC Converter Step Up (NGTRCSU) Craft Terminal (CT) Boards of 1670SM Shelf: Control & General I/F HC (CONGIHC) Equipment Controller Card (EQUICO) Matrix HI-CAP (HCMATRIX) Termination Bus 1670 (BTERM) 1 x STM64 Link (S64MLINK) 4 x 140 Port (P4E4) 2 x 140 Adapter (A2E4) 4 x STM-1 Electrical Port (P4ES1) 4 x STM-1 Electrical (A4ES1) High Speed Protection (HPROT) 16 x STM-1 Opt/El Port (P16S1) 16 x STM-1 Electrical Access (A16ES1) 16 x High Speed Protection (HPROT16) 16 x STM-1 Optical Port Compact ( P16OS1) 12 x STM-1 Optical Access Compact (A12OS1) 4 x STM-4 Port (P4S4) 2 x STM-4 Access (A2S4) 1670SM FAN Unit (FANC) Boards of 1662MC Shelf: Control & General I/F HC (CONGI) Compact STM-16 (SYNTH16) Termination Bus 1662 (TBUS) 63 x 2MBit/s Port (P63E1) 63 x 2MBit/s Port with retiming (P63E1NM4) 63 x 2MBit/s Prot. (75 OHM) (A63E1-4TE) 63 x 2MBit/s Prot. (120 OHM) (A63E1-120) Low Speed Protection (LPROT) 1662 SMC FAN Unit (FAN) Modules: All types of I/O modules Equipment Controller 1662 (EQUICO62)
Table 9
26
Equipment Alarms/Processing Error Alarms - 2
3AG 24197 ACAA - Ed. 04
Communication Alarm / Processing Error Alarm Correlation Element Type - Probable Cause Transmission broken
STM-1, STM-4, STM-16 STM-64
140MB
Gigabit Ethernet
2MB
MX640/ 320GA
AIS
CSF
LOA
LOF
LOMF
LOP
LOS
PLTM
RDI
SQM
SSF
TF
TIM
U
OSTTP
–
–
–
X
–
–
X
–
–
–
–
X
–
–
ESTTP
–
–
–
X
–
–
X
–
–
–
–
–
–
–
RSTTP
–
X
–
–
–
–
–
–
–
–
X
–
X f)
–
MSTTP
X
X
–
–
–
–
–
–
X
–
X i)
–
–
–
MSP
–
–
–
–
–
X g)
–
–
X
–
X i)
–
–
–
AU-4 CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
AU-3 CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
AU-4-4c CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
AU-4-16c CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
AU-4-64c CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
modVC-4 TTP
–
–
–
–
X
–
–
X
X
–
X
–
X f)
X
TU-3 CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
TU-12 CTP
X
–
–
–
–
X
–
–
X c)
–
X c)
–
X c)
X c)
PPITTP
–
–
–
–
–
–
X
–
–
–
–
–
–
–
E4 CTP
–
–
–
–
–
–
–
–
–
–
–
–
–
–
P4 CTP
–
–
–
–
–
–
–
X
–
–
–
–
–
–
VC-4 TTP
–
–
–
–
–
–
–
–
X
–
X
–
X f)
X
GMAU TTP
–
–
–
–
–
–
X
–
–
–
–
–
–
–
VC-4-Xv TTP
–
–
–
–
–
–
–
X
–
–
X
–
–
–
VC-3-Xv TTP
–
–
–
–
–
–
–
X
–
–
X
–
–
–
PTC
–
–
X
–
–
–
–
–
–
–
–
–
–
–
VC-4V TTP
–
–
–
–
X
–
–
–
X
Xj)
X
–
–
X
VC-3V TTP
–
–
–
–
X
–
–
–
X
Xj)
X
–
–
X
PPITTP
–
–
–
–
–
–
X
–
–
–
–
–
–
–
E1 CTP
X
–
–
X
X
–
–
–
X
–
X
–
–
–
P12 CTP h )
X
–
–
X
–
–
–
X
X
–
X
–
–
–
VC-12 TTP h)
–
–
–
–
–
–
–
–
X
–
X
–
X f)
X
sPPI
X
–
–
–
–
–
X
–
–
–
–
–
–
–
Table 10
Communication Alarms - 1
Legend of Table 10 to Table 11 AIS
3AG 24197 ACAA - Ed. 04
Alarm Indication Signal
27
28
DS
Degraded Signal
CSF
Communication Subsystem Failure
LOA
Loss Of Alignment
LOF
Loss Of Frame
LOMF
Loss Of Multiframe
LOP
Loss Of Pointer
LOS
Loss Of Signal
PLTM
Payload Type Mismatch
RDI
Remote Defect Indication
SQM
Sequence (Number) Mismatch
SSF
Server Signal Fail
TD
Transmitter Degraded
TIM
Trace Identifier Mismatch
TF
Transmitter Failure
UAT FE
Unavailable Time, Far End
UAT NE
Unavailable Time, Near End
URU
Underlying Resource Unavailable
UNEQ
Unequipped
3AG 24197 ACAA - Ed. 04
Communication Alarm / Processing Error Alarm Correlation Element Type - Probable Cause (continued) Transm. broken (cont.)
STM-1, STM-4, STM-16 STM–64
140MB
Gigabit Ethernet
2MB
MX640/ 320GA
Transm. with errors
Transm. ok
URU
UAT NE e)
UAT FE e)
CPE
DS
TD
OSTTP
X
–
–
–
–
X
ESTTP
X
–
–
–
–
–
RSTTP
–
X
–
–
–
–
MSTTP
–
X
X
X
X
–
MSP
–
–
–
–
–
–
AU-4 CTP
–
X
X
–
X c)
–
AU-3 CTP
–
X
X
–
X c)
–
AU-4-4c CTP
–
X
X
–
X c)
–
AU-4-16c CTP
–
X
X
–
X c)
–
AU-4-64c CTP
–
X
X
–
X c)
–
modVc-4 TTP
–
X
X
–
X
–
TU-3 CTP
–
X
X
–
X c)
–
TU-12 CTP
–
X
X
–
X c)
–
PPITTP
X
–
–
–
–
–
E4 CTP
–
–
–
–
–
–
P4 CTP
–
–
–
–
–
–
VC-4 TTP
–
X
X
–
X
–
GMAU TTP
X
–
–
–
–
–
VC-4-Xv TTP
–
–
–
–
–
–
VC-3-Xv TTP
–
–
–
–
–
–
PTC
–
–
–
–
–
–
VC-4V TTP
–
X
X
–
X
–
VC-3V TTP
–
X
X
–
X
–
PPITTP
X
–
–
–
–
–
E1 CTP h )
–
X
X
–
X
–
P12 CTP h )
–
X
X
–
X
–
VC-12 TTP
–
X
X
–
X
–
sPPI
–
–
–
–
–
–
Table 11
Communication Alarms - 2
Annotations of Table 8 to Table 11 a ) Replaceable Unit Missing" is alarmed with severity MAJOR in case of not protected boards and with severiĆ ty MINOR in case of protected boards.
3AG 24197 ACAA - Ed. 04
29
b ) The alarms Replaceable Unit Type Mismatch" and Software Download Failure" occur with severity WARNING in the context of board plugĆin or initializaĆ tion. Therefore this alarm should be seen as warning that the board has to be exchanged in order to be taken into operation. In that context no service is affected (yet). c ) Alarmed only, if POM/SUT is enabled. The alarm icons are displayed at the monitor icon. d ) Alarmed only, if TTI check is enabled in the TP ConfigĆ uration dialog. e ) Not alarmed at TP icons. Alarmed only in Alarm SurĆ veillance (AS), D
if current data is created for performance monitoring and POM/SUT is enabled in case of SDH TPs.
D
if current data is created for performance monitoring in case of Gigabit Ethernet TPs.
f ) Alarmed only, if TTI check is enabled in the TP ConfigĆ uration dialog. g ) Alarmed only in alarm list, not at MSP icon in Port View. h ) Alarmed only, if Framed Mode is switched on. Only PLTM is alarmed independent of Framed Mode. i ) Alarmed only, if LOS, LOF and TIM are not disabled in OED 1662 or 1670. j ) Alarmed only, if LCAS is disabled. Quality of Service Alarm Correlation Element Type - Counted Attributes All quality of service alarms shown in the alarm list below are threshold alarms. A threshold crossing of the counted attributes is indicated by the probable cause thresholdCrossed". The E4 CTP and P4 CTP do not support PM and therefore do not report any Threshold Crossing Alarms.
30
3AG 24197 ACAA - Ed. 04
BBE
ES
SES
FE BBE
RSTTP
X
X
X
–
–
–
MSTTP
X
X
X
X
X
X
AU-4 CTP
X
X
X
X
X
X
AU-3 CTP
X
X
X
X
X
X
AU-4-4c CTP
X
X
X
X
X
X
AU-4-16c CTP
X
X
X
X
X
X
AU-4-64c CTP
X
X
X
X
X
X
modVC-4 TTP
X
X
X
X
X
X
TU-3 CTP
X
X
X
X
X
X
TU-12 CTP
X
X
X
X
X
X
VC-4 TTP
X
X
X
X
X
X
VC-4V TTP
X
X
X
X
X
X
VC-3V TTP
X
X
X
X
X
X
VC-12 TTP
X
X
X
X
X
X
E1 CTP
X
X
X
–
–
–
P12 CTP
X
X
X
–
–
–
Table 12
FE ES
FE SES
Threshold Crossing Alarms
Legend of Table 12
3AG 24197 ACAA - Ed. 04
BBE
Block Bit Error
ES
Errored Second
FE
Far End
NE
Near End
SES
Severely Errored Second
31
32
3AG 24197 ACAA - Ed. 04
4
Equipment Alarms/Processing Error Alarms
4.1
Battery Failure (BF) The Battery Failure alarm situation is indicated by the board state faulty", which implies that the equipment is totally inoperable. Event Type:
Equipment alarm
Probable Cause: Battery Failure (BF) Board Type: Control & General I/F HC (CONGIHC) , Control & General I/F (CONGI) Condition causing indication: Defective converter. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the respective subrack. If the second power conĆ verter in this subrack also fails, all traffic passing through this subrack is affected. Recommended action: Replace the CONGI/ CONGIHC (. Maintenance HandĆ book) that reports the Battery Failure . Alternatively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
33
Event Type:
Equipment alarm
Probable Cause: Battery Failure (BF) Board Type:
Power Supply/Filter (PSF)
Condition causing indication: Missing top rack unit battery voltage or defective PSF. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the respective subrack. If the second PSF in this subrack also fails, all traffic passing through this subrack is affected. Recommended action:
34
1
Check the presence of the relevant Station Power Supply (BatteryĆA and BatteryĆB) on PSF units and check that cable between top rack unit battery and PSF card is plugged.
2
If the relevant Station Power Supply on the PSF units are present and there is no cabling problem, the PSF is defective. Replace the PSF (. Maintenance Handbook) that reports the Battery Failure. Alternatively call your Technical Assistance Center for replacing the PSF.
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Battery Failure (BF) Board Type
1678MCC Fan Unit (FAN78)
Condition causing indication: Defective power connection of the the Fan Unit(e.g. connecĆ tion in the backpanel) or defective Fan Unit. Effect on service: No effect on transmission yet. But because of the reduced FAN capacity there is the danger of exceeding the maximum operation temperature within the subrack. If the maximum operation temperature exceeds, the system will overheat and therefore be damaged. Recommended action: Make sure that the power connection of the Fan Unit is OK. If the power connection of the FAN Unit is OK and the BatĆ tery Failure alarm is still reported, immediately replace the Fan Unit as quickly as possible (. Maintenance Handbook). If the problem cannot be solved, call your Technical AssisĆ tance Center for help.
3AG 24197 ACAA - Ed. 04
35
Event Type:
Equipment alarm
Probable Cause: Battery Failure (BF) Board Type
1670SM FAN Unit (FANC), 1662SMC FAN Unit (FAN)
Condition causing indication: Missing connection to Top Rack Unit (TRU) or defective FAN. Effect on service: No effect on transmission yet. But because of the reduced FAN capacity there is the danger of exceeding the maximum operation temperature within the subrack. Recommended action:
36
1
Check the cabling between TRU and FAN.
2
Check fuse of FAN at TRU.
3
If there is no cabling or fuse problem, call your Technical Assistance Center for help.
3AG 24197 ACAA - Ed. 04
4.2
Communications Subsystem Failure (CSF) Event Type:
Equipment alarm
Probable Cause: Communications Subsystem Failure (CSF) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G (LAX40), LO Adaptation/Matrix 20G (LAX20), Matrix HIĆCAP (HCMATRIX), Equip. Controller Card (EQUICO), Compact STM-16 (SYNTH16)
Condition causing indication: No active controller available. Effect on service: -
new configuration of equipment within the shelf is not possible
-
Performance Monitoring and Alarm Reporting is suspended
-
Communication within the shelf is suspended.
-
Transmission not affected.
Recommended action: -
make sure that both redundant boards are plugged
-
if both redundant boards are plugged, wait until one of the controllers becomes active again. The CSF alarm is cleared, after one of the controller is active.
If the problem cannot be solved, call your Technical AssisĆ tance Center for help.
3AG 24197 ACAA - Ed. 04
37
4.3
Fuse Failure (FF) The Fuse Failure alarm situation is indicated by the board state faulty", which implies that the equipment is totally inoperable. The Fuse Failure alarm lights the red led on the card frontĆ panel, like RUP alarm. Event Type:
Equipment alarm
Probable Cause: Fuse Failure (FF) Board Type:
Power Supply/Filter (PSF)
Condition causing indication: The battery fuse of the PSF unit that reports the alarm is broken. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the respective subrack. If the second power conĆ verter in this subrack also fails, all traffic passing through this subrack is affected. Recommended action: Substitute the PSF unit. Alternatively call your Technical Assistance Center for support. Fuse Failure alarm cannot be raised on a PSF card, for which top rack unit battery voltage is missing.
38
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Fuse Failure (FF) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20), FLCCONGI, FLCSERV, FLCSERVA, Termination Bus (BUSTERM), 16 x STM4/1 Port (P16S1S4), 16 x STM16 Port (P16S16), 8 x STM16 Port (P8S16), 4 x STM16 Port (P4S16), 16 x STM1 Port (P16S1S), STMĆ64 MSA Port (S64M), 2 x STMĆ64 MSA Port (P2S64M), 4 x STMĆ64 MSA Port (P4S64M), 4 x STM-64 XFP Port (P4S64X), 2 x STM-64 XFP Port (P2S64X), 2 x STM-64 XFP Port (P2S64X), 16 x GE Port (P16GE), 8 x GE Port (P8GE), 4 x GE Port (P4GE)
Condition causing indication: The battery fuse of the board that reports the alarm is broĆ ken. Effect on service: If the board is protected, transmission is not affected, but there is no redundancy any more. If the board is unprotected, transmission is affected. Recommended action:
3AG 24197 ACAA - Ed. 04
39
Substitute the board that reports the Fuse Failure alarm. Alternatively call your Technical Assistance Center for supĆ port. Fuse Failure alarm cannot be raised on a board, if battery voltage is missing on the same branch where the fuse is broĆ ken.
40
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Fuse Failure (FF) Board Type:
1678MCC Fan Unit (FAN78)
Condition causing indication: The battery fuse of the unit that reports the alarm is broĆ ken. Effect on service: The Fan Unit does not work properly. There is the danger of system overheat. Recommended action: Substitute the fan unit. Alternatively call your Technical Assistance Center for support. Fuse Failure alarm cannot be raised on a board, if battery voltage is missing on the same branch where the fuse is broĆ ken.
3AG 24197 ACAA - Ed. 04
41
Event Type:
Equipment alarm
Probable Cause: Fuse Failure (FF) Board Type: Control & General I/F HC (CONGIHC) , Control & General I/F (CONGI) Condition causing indication: Defective fuse. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the respective subrack. If the second power conĆ verter in this subrack also fails, all traffic passing through this subrack is affected. Recommended action: Replace the CONGI/ CONGIHC (. Maintenance HandĆ book). Alternatively call your Technical Assistance Center for support.
42
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Fuse Failure (FF) Board Type: DC/DC Converter Step Up (NGTRCSU) Condition causing indication: Input voltage at the DC/DC Converter Step Up board is beĆ low -38V. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the 1678 Main Shelf. If the second NGTRCSU also fails, all traffic passing through the 1678 Main Shelf will be affected. Recommended action: Provide correct input voltage for the DC/DC Converter Step Up board that reports the alarm. Alternatively call your Technical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
43
4.4
High Temperature (HT) Event Type:
Equipment alarm
Probable Cause: High Temperature (HT) Board Type:
1678MCC Fan Unit (FAN78)
Condition causing indication: The subrack temperature exceeds the maximum operation temperature. -
the Fan Unit is faulty.
-
the air vents are covered.
The Fan Unit has three temperature sensors. The TemperaĆ ture High Temperature alarm is raised on a Fan Unit, if at least one temperature sensor indicates a value greater than the maximum temperature. Effect on service: No effect on transmission yet, but the Fan Unit does not work properly. There is the danger of system overĆ heat. Recommended action: Check if the Fan Unit works properly and the air vents are not covered. If the air vents are not covered, but the Fan Unit does not work properly, immediately replace the Fan Unit as quickly as possible (. Maintenance Handbook).
44
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: High Temperature (HT) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20), FLCCONGI, FLCSERV, FLCSERVA, 16 x STM4/1 Port (P16S1S4), 16 x STM16 Port (P16S16), 8 x STM16 Port (P8S16), 4 x STM16 Port (P4S16), 16 x STM1 Port (P16S1S), STMĆ64 MSA Port (S64M), 2 x STMĆ64 MSA Port (P2S64M), 4 x STMĆ64 MSA Port (P4S64M), 4 x STM-64 XFP Port (P4S64X), 2 x STM-64 XFP Port (P2S64X), 2 x STM-64 XFP Port (P2S64X), 16 x GE Port (P16GE), 8 x GE Port (P8GE), 4 x GE Port (P4GE)
Condition causing indication: The subrack temperature exceeds the maximum operation temperature. -
the Fan Unit is faulty.
-
the air vents are covered.
All boards have a temperature sensor. The Temperature High Temperature alarm is raised, if the temperature senĆ sor indicates a value greater than the maximum temperaĆ ture. Effect on service: No effect on transmission yet, but the Fan Unit does not work properly. There is the danger of system overheat.
3AG 24197 ACAA - Ed. 04
45
Recommended action: Check if the Fan Unit works properly and the air vents are not covered. If the Fan Unit works properly and the air vents are not covĆ ered replace the board (. Maintenance Handbook). AlterĆ natively call your Technical Assistance Center for support.
46
3AG 24197 ACAA - Ed. 04
4.5
Internal Communication Problem (ICP) Event Type:
Equipment alarm
Probable Cause: Internal Communication Problem (ICP) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20)
Condition causing indication: The ISSB connection between FLC and the matrix board that reports the ICP alarm is lost. Effect on service: -
If the connection to the active matrix board has been lost, an automatic equipment protection switch has been performed, that may cause a transmission hit (<50ms).
-
If the connection to the passive matrix board has been lost, there is no effect on transmission, if no second fault occurs.
In both cases matrix redundancy is not available anymore. Recommended action: Call your Technical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
47
Event Type:
Equipment alarm
Probable Cause: Internal Communication Problem (ICP) Board Type:
Matrix HIĆCAP (HCMATRIX), Compact STM-16 (SYNTH16)
Condition causing indication: Connection to the FLC in the 1678MCC main shelf is lost. Effect on service: -
Transmission is not affected.
-
Alarms are not reported anymore for the affected subsystem (OED).
-
Management operations or change of configuration within the affected subsystem are not possible.
Recommended action: Call your Technical Assistance Center for support.
48
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Internal Communication Problem (ICP) Board Type:
FLCCONGI, FLCSERV, FLCSERVA
Condition causing indication: Communication between the active and passive FLC is lost. Effect on service: -
No FLC redundancy.
-
Transmission not affected.
Recommended action: Call your Technical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
49
4.6
Input Power Loss (IPL) Event Type:
Equipment alarm
Probable Cause: Input Power Loss (IPL) Module Type:L64.2 MSA Optical Interface (ML642), V64.2 MSA Optical Interface (MV642), U64.2 MSA Optical Interface (MU642) Condition causing indication: The input signal of the booster is faulty. Effect on service: Transmission is broken, output signal of the booster is switched off. Recommended action: Check the loop cable to the booster input. If there is no cabling problem replace the S64M board (. Maintence Handbook). Alternatively call your TechniĆ cal Assistance Center for support.
50
3AG 24197 ACAA - Ed. 04
4.7
LAN Failure (LAN) Event Type:
Equipment alarm
Probable Cause: LAN Failure (LAN) Board Type:
FLCCONGI, FLCSERV, FLCSERVA
Condition causing indication: The ISSB redundancy between the active and passive FLC is lost. Both FLCs generate this alarm. Effect on service: Traffic is not affected. Recommended action: Call your Technical Assistance Center for support. Service personnel must be aware that repairing the FLCĆ FLC connection may lead to the problem of having two acĆ tive FLCs, if all interĆFLC cables are lost. It is recomĆ mended to shut down the passive FLC for any repair action on the interĆFLC cabling.
3AG 24197 ACAA - Ed. 04
51
Event Type:
Equipment alarm
Probable Cause: LAN Failure (LAN) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20)
Condition causing indication: Failure of one of the redundant ISSB interfaces on the maĆ trix board that reports the LAN failure. Effect on service: Traffic is not affected. No ISSB interface redundancy. Recommended action: Replace the matrix board which reports the LAN Failure. Alternatively call your Technical Assistance Center for reĆ placing the board.
52
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: LAN Failure (LAN) Board Type:
Matrix HIĆCAP (HCMATRIX), Equip. Controller Card (EQUICO)
Condition causing indication: Failure of the ISSB interface in the backpanel. Backpanel is defective. Effect on service: Traffic is not affected. Recommended action: Call your Technical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
53
4.8
No RTC Synchronization (NRTCS) Event Type:
Equipment alarm
Probable Cause: No RTC Synchronization (NRTCS) Board Type:
FLCCONGI, FLCSERV, FLCSERVA
Condition causing indication: The xntpdSupervision process, running on the active FLC states a time source problem. This may be due to a: -
Power Failure of the time server
-
LAN communication problem to the time server
-
NTP problem on the time server
Effect on service: The system is still operable and transmission is not afĆ fected. Both FLCs change to local time selection with deĆ fined time drift. The time drift may influence the perforĆ mance measurement accuracy. The passive FLC does not report the RTC alarm. In case of an FLC switch,the alarm will not be moved to the new acĆ tive FLC but is still bound to the new passive FLC. Recommended action: Call your Technical Assistance Center for support. The NRTCS alarm is handled by the active FLC but not by the standĆby FLC.
54
3AG 24197 ACAA - Ed. 04
4.9
Optical Connector Cover Open (OCCO) The Optical Connector Cover Open alarm situation is indiĆ cated by the module state faulty", which implies that the equipment is totally inoperable. Event Type:
Equipment alarm
Probable Cause: Optical Connector Cover Open (OCCO) Module Type: L64.2 MSA Optical Interface (ML642), V64.2 MSA Optical Interface (MV642), U64.2 MSA Optical Interface (MU642) Condition causing indication: The connector cover is not fixed to the front plate. Effect on service: Laser is automatically shut down. Recommended action: Fasten the connector cover and tighten it with the screw.
3AG 24197 ACAA - Ed. 04
55
4.10
Pump Failure (PF) Event Type:
Equipment alarm
Probable Cause: Pump Failure (PF) Module Type: L64.2 MSA Optical Interface (ML642), V64.2 MSA Optical Interface (MV642), U64.2 MSA Optical Interface (MU642) Condition causing indication: Optical booster is defective. Effect on service: Laser does not work. Recommended action: Replace the STM-64 board that supports the defect modĆ ule (. Maintenance Handbook) or call your Technical AsĆ sistance Center for support.
56
3AG 24197 ACAA - Ed. 04
4.11
Resource Isolation (Q3) Event Type:
Equipment alarm
Probable Cause: Resource Isolation (Q3) Board Type:
Craft Terminal (CT)
Condition causing indication: Failure of the connection between the CT and the NE due to -
defective cable connection
-
failure of the QIA process
-
failure of the MIB
Effect on service: Traffic is not affected. Recommended action: 1
Check the cabling between CT and NE
2
If there is no cabling problem, call your Technical Assistance Center
After a short interruption of the connection between the CT and FLC (about 20 to 30 seconds), the CT reconnection atĆ tempts may be rejected by the FLC because the FLC does not detect the interruption. Make sure the LAN cable between the CT and FLC is interĆ rupted for at least 30 seconds. The reconnection is then handled correctly from both the CT and the FLC.
3AG 24197 ACAA - Ed. 04
57
4.12
Redundant Clock Fail A/B (RCFA/B) Event Type:
Equipment alarm
Probable Cause: Redundant Clock Fail A/B (RCFA/B) Board Type:
Matrix HIĆCAP (HCMATRIX)
Condition causing indication: The HCMATRIX Board does not receive the redundant clock signal. Effect on service: Transmission hit in some cases. Recommended action: Check whether only the single board or the entire system is affected:
58
-
if a single board is affected, replace the board or call your Technical Assistance Center for replacing the board.
-
otherwise, check the common elements of the clock distribution hardware that provide redundant clock signal for the affected subsystems, i.e. the MX640 boards, the LINK Board in position 21 for RCFA or the LINK Board in position 22 for RCFB.
-
occurs if the related link is disabled.
-
if still no problem is detected, call yourTechnical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Redundant Clock Fail A/B (RCFA/B) Board Type:
Compact STM-16 (SYNTH16)
Condition causing indication: The SYNTH16 Board does not receive the redundant clock signal. Effect on service: Transmission hit in some cases. Recommended action: Check whether only the single board or the entire system is affected:
3AG 24197 ACAA - Ed. 04
-
if a single board is affected, replace the board or call your Technical Assistance Center for replacing the board.
-
if still no problem is detected, call your Technical Assistance Center for support.
59
4.13
Redundant Matrix A/B Failure (RMFA/B) Event Type:
Equipment alarm
Probable Cause: Redundant Matrix A/B Failure (RMAF/ RMBF) Board Type:
Matrix HIĆCAP (HCMATRIX)
Condition causing indication: The board that reports the alarm does not receive a valid signal from center stage matrix copy A/B. If the signal of the active matrix copy has been affected, a matrix EPS to the matrix with the good signal automaticalĆ ly has been performed. Effect on service: Matrix redundancy is not available. No effect on transmisĆ sion, if no second fault occurs. Recommended action: Check the cable connections between the matrix and the board that reports the alarm for failure. If the problem cannot be solved, call your Technical AssisĆ tance Center for help.
60
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Redundant Matrix A/B Failure (RMAF/ RMBF) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160)
Condition causing indication: The signal between matrix and I/O board and is disturbed. If the signal of the active matrix copy has been affected, a matrix EPS to the matrix with the good signal automaticalĆ ly has been performed. Effect on service: Matrix redundancy is not available. No effect on transmisĆ sion, if no second fault occurs. Recommended action: Call your Technical Assistance Center for help.
3AG 24197 ACAA - Ed. 04
61
4.14
Replaceable Unit Missing (RUM) Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
FLCCONGI, FLCSERV, FLCSERVA
Condition causing indication: The application processes running on the active FLC have no contact to the remote database handler running on the passive FLC. This may be due to the -
application not running on the passive FLC
-
passive FLC being in HALT state (no application running)
-
passive FLC having no power supply
-
FLCs not being connected by LAN/Ethernet
-
FLC cold start (alarm automatically disappears after 5 minutes)
Effect on service: The system is still operable and transmission is not afĆ fected, but the FLC runs without redundancy (i.e. if active FLC fails, the system is no longer operable). Recommended action:
62
-
check the LAN/Ethernet communication
-
call your Technical Assistance Center to reinstall the passive FLC (. Installation and StartĆUp ManualFLC Software).
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type: Control & General I/F HC (CONGIHC) , Control & General I/F (CONGI), Power Supply/Filter (PSF) Condition causing indication: The reasons for the alarm may be: -
the board is pulled out
-
the fuse of the board is switched off
-
a hardware failure of the board
Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system in this subrack runs without redundancy. If the second board in this partsystem also fails, all traffic passing through this subrack will be lost. If a CONGI or CONGIHC reports a RUM alarm, additionalĆ ly the LAN connection to the SC of the1678MCC main shelf will be lost. Recommended action:
3AG 24197 ACAA - Ed. 04
-
plug in the board
-
switch on the fuse of the board
-
replace the board (. Maintenance Handbook). Alternatively call your Technical Assistance Center for replacing the board.
63
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type: High Speed Protection (HPROT), 16 x High Speed Protection (HPROT16), Low Speed Protection (LPROT) Condition causing indication: The requested element is not reachable. Effect on service: Transmission is not affected unless the alarm is raised durĆ ing I/O board protection switching. I/O board redundancy is no longer available in the affected subrack. Recommended action: Insert the board correctly or replace it (. Maintenance Handbook).
64
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20), Matrix HIĆCAP (HCMATRIX), Compact STM-16 (SYNTH16)
Condition causing indication: The reasons for the alarms are: -
the board is plugged out
-
hardware failure of the matrix board (e.g. both ISSB interfaces are defective)
Effect on service: The board is protected automatically if the protection maĆ trix board is available. Recommended action:
3AG 24197 ACAA - Ed. 04
-
plug in the board
-
replace the matrix Board. Alternatively call your Technical Assistance Center for replacing the board.
65
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
1 x STM64 Link (S64MLINK)
Condition causing indication: The reasons for the alarms are: -
the board is plugged out
-
hardware failure of the board
Effect on service: The board is protected automatically, if the OED link is MSP protected. If the link is unprotected or both links of a protection schema are defective, traffic is affected. Recommended action: Plug in the board correctly or replace the board. AlternaĆ tively call your Technical Assistance Center for replacing the board.
66
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Module Type:
Equip. Controller 1662 (EQUICO62), Equip. Controller Card (EQUICO)
Condition causing indication: The requested element is not reachable. Effect on service: DCC communication is not possible for this subrack. Recommended action:
3AG 24197 ACAA - Ed. 04
-
In case of EQUICO insert the Equipment Controller Card correctly or replace it.
-
In case of EQUICO62 insert the SYNTH16 board correctly or replace it.
-
Alternatively call your Technical Assistance Center for replacing the card.
67
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
all protected I/O boards
Condition causing indication: The requested element is not reachable. Effect on service: The board is protected automatically if protection is configĆ ured and enabled. Recommended action: Insert the board correctly or replace it (. Maintenance Handbook).
68
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Equipment Type:
all unprotected I/O boards, all I/O modules
Condition causing indication: The requested element is not reachable. Effect on service: Transmission is broken. Recommended action: Insert the board correctly or replace it (. Maintenance Handbook). If the alarm is reported by a module, check whether the module is available/ plugged.
3AG 24197 ACAA - Ed. 04
69
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
Termination Bus 1670 (BTERM), Termination Bus (BUSTERM), Termination Bus 1662 (TBUS)
Condition causing indication: The requested element is not reachable. The board is not correctly inserted or has to be replaced. Effect on service: Transmission is broken. No communication is possible within this shelf. Recommended action: Replace the board. Alternatively call your Technical AssisĆ tance Center for replacing the board.
70
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Missing (RUM) Board Type:
1678MCC Fan Unit (FAN78)
Condition causing indication: The requested element is not reachable. Effect on service: Without Fan Unit the system will overheat. As a conseĆ quence boards will break down and transmission will be lost. Recommended action: As soon as possible insert the board correctly or replace it (. Maintenance Handbook). Alternatively call your TechĆ nical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
71
4.15
Replaceable Unit Problem (RUP) The Replaceable Unit Problem alarm situation is indicated by the board state faulty", which implies that the equipĆ ment is totally inoperable. Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
FLCCONGI, FLCSERV, FLCSERVA
Condition causing indication: Hardware error. This may be due to the: -
application not running on passive FLC
-
passive FLC in HALT state (no application running)
-
passive FLC having no power supply
-
FLC cold start (alarm automatically disappears after 5 minutes)
Effect on service: The system is still operable and transmission is not affected but the FLC runs without redundancy (i.e. if active FLC fails, the system is no longer operable). Recommended action: -
72
call your Technical Assistance Center to reinstall the passive FLC.
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type: Control & General I/F HC (CONGIHC) , Control & General I/F (CONGI), Power Supply/Filter (PSF) Condition causing indication: Board is defective. Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the respective subrack. If the second power conĆ verter in this twin subrack also fails, all traffic passing through this subrack is affected. Recommended action: Replace the board (. Maintenance Handbook). AlternaĆ tively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
73
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type: High Speed Protection (HPROT), 16 x High Speed Protection (HPROT16), Low Speed Protection (LPROT) Condition causing indication: Board is defective. Effect on service: Transmission is not affected unless the alarm is raised durĆ ing I/O board protection switching. I/O board redundancy is no longer available in the affected subrack. This situation is indicated by the board state faulty". Recommended action:
74
1
Reset both Matrix Boards in the subrack in which the affected board is located.
2
In case action 1 is not successful, replace the board (. Maintenance Handbook). Alternatively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
Equip. Controller Card (EQUICO)
Condition causing indication: Board is defective. Effect on service: Transmission is not affected. The DCC communication of this subrack is disturbed. Recommended action: Replace the Equipment Controller Card. Alternatively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
75
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), LO Adaptation/Matrix 20G (LAX20), Matrix HIĆCAP (HCMATRIX), Compact STM-16 (SYNTH16)
Condition causing indication: Board is defective. Effect on service: The previous configuration is still in service and the traffic is not affected. A new configuration is not possible before the fault is cleared. Recommended action:
76
1
Reset the board.
2
In case action 1 is not succesful, replace the board. Alternatively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
1 x STM64 Link (S64MLINK)
Condition causing indication: Board is defective (HW problem). Effect on service: The board is automatically protected, if the OED link is MSP protected. If the link is unprotected or both links of a protections schema are defective, traffic may be affected deĆ pending on the hardware problem. Recommended action: Replace the board (. Maintenance Handbook).
3AG 24197 ACAA - Ed. 04
77
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Module Type:
all I/O modules
Condition causing indication: Module is defective. Effect on service: The transmission passing through the related board is afĆ fected. Recommended action: If the module is exchangeable, replace the module. OtherĆ wise replace the related I/O board (. Maintenance HandĆ book). Alternatively call your Technical Assistance Center for replacing the module/ board.
78
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Equipment Type:all I/O boards Condition causing indication: The board or module that reports the alarm is defective. Effect on service: The previous configuration is still in service and the traffic is not affected. A new configuration is not possible before the fault is cleared. Recommended action: Replace the board (. Maintenance Handbook).
3AG 24197 ACAA - Ed. 04
79
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
1678MCC Fan Unit (FAN78), 1670SM FAN Unit (FANC), 1662SMC FAN Unit (FAN)
Condition causing indication: The Fan Unit is defective. Effect on service: The Fan Unit does not work properly. There is the danger of system overheat. As a consequence of system overheat boards will break down and transmission will be lost. Recommended action: As soon as possible replace the Fan Unit (. Maintenance Handbook). Alternatively call your Technical Assistance Center for replacing the board.
80
3AG 24197 ACAA - Ed. 04
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type:
Termination Bus (BUSTERM), Termination Bus 1670 (BTERM), Termination Bus 1662 (TBUS)
Condition causing indication: Board is defective. Effect on service: Transmission is affected. No communication is possible within this shelf. The board has to be replaced. Recommended action: Replace the Bus Termination Board. Alternatively call your Technical Assistance Center for replacing the board.
3AG 24197 ACAA - Ed. 04
81
Event Type:
Equipment alarm
Probable Cause: Replaceable Unit Problem (RUP) Board Type: DC/DC Converter Step Up (NGTRCSU)
Condition causing indication: The DC/DC Converter Step Up board is defective due to the following reasons: -
the onĆboard fan is not running,
-
no ouput voltage from the board or
-
internal HW failure of the board.
Effect on service: The system is still operable and transmission is not afĆ fected, but the power supply system runs without redunĆ dancy in the 1678 Main Shelf. If the second NGTRCSU also fails, all traffic passing through the 1678 Main Shelf will be affected. Recommended action: Call your Technical Assistance Center for help.
82
3AG 24197 ACAA - Ed. 04
4.16
Replaceable Unit Type Mismatch (RUTM) The Replaceable Unit Type Mismatch alarm situation is inĆ dicated by the board state faulty", which implies that the equipment is totally inoperable. Event Type:
equipment alarm
Probable Cause: Replaceable Unit Type Mismatch (RUTM) Equipment Type:all boards except FANC and FAN62, all I/O modules Condition causing indication: The plugged in board or module that reports the RUTM alarm is either of the wrong type or its version does not match the current system configuration. Effect on service: It is not possible to configure this board or module. Recommended action: Plug in the correct board or module.
3AG 24197 ACAA - Ed. 04
83
4.17
Software Download Failure (SDF) Event Type:
Processing error alarm
Probable Cause: Software Download Failure (SDF) Board Type:
Matrix 640GBIT/S (MX640), Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S (MX320), Matrix 320GBIT/S Enh. (MX320GA), Matrix 160GBIT/S (MX160), LO Adaptation/Matrix 40G(LAX40), Matrix HIĆCAP (HCMATRIX), Compact STM-16 (SYNTH16)
Condition causing indication: An attempt to configure the board failed due to a commuĆ nication overload and resulting configuration timeout or due to erroneous configuration messages. Effect on service: None. Recommended action:
84
1
Reset the board from the CT using menu option Reset" from the Equipment View menu. The board then enters the state downloading for about 10 minutes and should change to in service afterwards.
2
If step 1 fails and downloading is not completed after about 10 minutes, contact your Technical Assistance Center.
3AG 24197 ACAA - Ed. 04
Event Type:
Processing error alarm
Probable Cause: Sfwr Download Failure (SDF) Board Type:
FLCCONGI FLCSERV, FLCSERVA
Condition causing indication: An attempt to configure the board failed due to a commuĆ nication overload and resulting configuration timeout or due to erroneous configuration messages. Effect on service: None. Recommended action: Call your Technical Assistance Center for support.
3AG 24197 ACAA - Ed. 04
85
4.18
Software Environment Problem (SEP) Event Type:
Processing error alarm
Probable Cause: Software Environment Problem (SEP) Board Type:
FLCSERV, FLCSERVA, FLCCONGI
Condition causing indication: The passive FLC runs in system recovery mode, i.e. the pasĆ sive FLC performs a file system recovery from the save area (e.g. file system full, UNIX crash). Effect on service: Traffic is not affected, but there is no FLC redundancy available during the recovery state. Recommended action: Wait until the recovery scenario has finished (this may take some minutes). The alarm is then automatically cleared.
86
3AG 24197 ACAA - Ed. 04
4.19
Timing Problem (TIP) Event Type:
Equipment alarm
Probable Cause: Timing Problem (TIP) Board Type:
Matrix HIĆCAP (HCMATRIX), Compact STM-16 (SYNTH16)
Condition causing indication: -
the Matrix Board receives no clock signal, or
-
the Matrix Board cannot identify the frame start indication within the selected clock signal.
Effect on service: -
transmission is interrupted
-
automatic protection of the connection takes place if enabled.
Recommended action: Check whether the single board alone or the entire system is affected:
3AG 24197 ACAA - Ed. 04
-
if just a single board is affected, replace it. Alternatively call your Technical Assistance Center for replacing the board.
-
otherwise, check the elements of the clock distribution hardware that are common for the affected subsystems, i.e. MX640 cables.
-
if still no problem is detected, call your Technical Assistance Center for support.
87
88
3AG 24197 ACAA - Ed. 04
5
Communications Alarms/ Processing Error Alarms
5.1
Abstract All alarms are only reported on TPs where alarm reporting is enabled. Alarm reporting on each TP can be enabled/disabled separately. Remark concerning Element Type: TP names as shown on Craft Terminal (TP names accordĆ ing to ITUĆT in brackets)
3AG 24197 ACAA - Ed. 04
89
5.2
Alarm Indication Signal (AIS) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Alarm Indication Signal (AIS) Element Type:
MST (MSTTP)
Condition causing indication: Maintenance signal. There is a problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to the NE is broken. Recommended action: Repair connected SDH equipment / link or activate a path protection.
90
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Alarm Indication Signal (AIS) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP). Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP)
Condition causing indication: The incoming AU4Ć/ AU3Ćpointer is in AISĆstate (Annex C, G.783). Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to the NE is broken. Recommended action: Repair connected SDH equipment / link or activate a path protection.
3AG 24197 ACAA - Ed. 04
91
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Alarm Indication Signal (AIS) Element Type:
Tu3 (TUĆ3 CTP), Tu12 (TUĆ12 CTP)
Condition causing indication: The incoming TU3Ć/ TU12Ćpointer is in AISĆstate (Annex C, G.783). Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to the NE is broken. Recommended action: Repair connected SDH equipment / link or activate a path protection.
92
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
64 x 2Mbit/ s Board
Probable Cause: Alarm Indication Signal (AIS) Element Type:
E1 (E1 CTP), P12 (P12 CTP)
Condition causing indication: The incoming signal is fixed at FF" ("All-ones"). Problem at connected PDH equipment or at the link from connected PDH equipment to the NE. Effect on service: Transmission from connected PDH equipment to the NE is broken. Recommended action: Repair connected PDH equipment / link or activate a path protection.
3AG 24197 ACAA - Ed. 04
93
Event Type:
Communication alarm
Board Type:
Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S Enh. (MX320GA)
Probable Cause: Alarm Indication Signal (AIS) Element Type:
sPPI (sPPI)
Condition causing indication: The incoming signal is fixed at FF" ("All-ones"). Problem at connected PDH equipment or at the link from connected PDH equipment to the NE. Effect on service: Transmission from connected PDH equipment to the NE is broken. No signal at associated 1544kbps T6 timing referĆ ence input. Recommended action: Repair connected PDH equipment/ link.
94
3AG 24197 ACAA - Ed. 04
5.3
Communication Protocol Error (CPE) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Communication Protocol Error (CPE) Element Type:
MST (MSTTP)
Condition causing indication: The received values of the K1/K2 used for MSP resp. MSĆ SPRING violate the rules defined for the protocol (undeĆ fined switch requests, not supported section number). Effect on service: The protection (MSP resp. MSĆSPRING) cannot operate properly. Neither automatic switch requests nor operator commands will (probably) be confirmed from the remote side. Therefore the switch cannot be completed. Recommended action: Check the configuration of the remote side. The remote protection group should operate in the same way as the loĆ cal one. In particular, both sides should operate bidirecĆ tional (dual ended) using the same protocol. If no access to the remote group is possible, the local group should be configured to operate unidirectional (single enĆ ded). In the single ended mode, the received K1/K2 is igĆ nored.
3AG 24197 ACAA - Ed. 04
95
96
3AG 24197 ACAA - Ed. 04
5.4
Communications Subsystem Failure (CSF) Event Type:
Communication alarm
Probable Cause: Communications Subsystem Failure (CSF) Board Type:
MST (MSTTP), RST (RSTTP)
Condition causing indication: Failure of the underlying LAPD connection due to one of the following reasons: 1
Wrong configuration of the LAPD role at the connection end points: Either both end points are configured as User or both are configured as Network.
2
Problem at the connection between the connected network nodes, e.g. fibre cut. This is indicated by an active LOS alarm at the related port TP.
3
Failure in transmission of D-bytes.
Effect on service: -
DCC not available. DCC traffic is lost.
Recommended action: Depending on the condition the has caused the alarm, perĆ form the following action: 1
Check the configuration of the LAPD interface and make sure that one end point of the connection is configured as User and the other as Network.
2
Check whether the incoming signal is correct, i.e. there is no active LOS alarm at the related port TP.
3
Make sure that the hardware needed for DCC is available and working and that the cabling is correct.
If the problem cannot be solved, call your Technical AssisĆ tance Center for help.
3AG 24197 ACAA - Ed. 04
97
5.5
Degraded Signal (DS) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Degraded Signal (DS) Element Type:
MST (MSTTP)
Condition causing indication: B2Ćerror rate (MSOH) higher than threshold is detected at the incoming signal. Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Bit errors at the received payload. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
98
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, Gigabit Ethernet Board (GETHM)
Probable Cause: Degraded Signal (DS) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP), Tu12 (TUĆ12CTP) with POM/SUT on
Condition causing indication: B3/BIPĆ2Ćerror rate (POH) higher than threshold is deĆ tected at the incoming signal. Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Bit errors at the received payload. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
99
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, Gigabit Ethernet Board (GETHM), 4 x 140/STMĆ1O/E Board
Probable Cause: Degraded Signal (DS) Element Type:
modVC4 (VCĆ4 TTP), Vc3V (VCĆ3V TTP), Vc4V (VCĆ4V TTP), Vc4 (VCĆ4 TTP)
Condition causing indication: B3Ćerror rate (POH) higher than threshold is detected at the incoming signal. Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Bit errors at the received payload. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
100
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
2 Mbit/s Board
Probable Cause: Degraded Signal (DS) Element Type:
E1 (E1 CTP), P12 (P12 CTP)
Condition causing indication: The bit error rate of the incoming signal exceeds 10Ć5 (10Ć6 if CRCĆ4 mode ON). Problem at connected PDH equipment or at the link from connected PDH equipment to the NE. Effect on service: Bit errors at the transmission from the connected PDH equipment to the NE. Recommended action: Repair connected PDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
101
Event Type:
Communication alarm
Board Type:
63 x 2Mbit/s Board
Probable Cause: Degraded Signal (DS) Element Type:
Vc12 (VCĆ12 TTP)
Condition causing indication: BIPĆ2Ćerror rate or tandem connection error rate greater than threshold is detected at the incoming signal. Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Bit errors at the received payload. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
102
3AG 24197 ACAA - Ed. 04
5.6
Loss of Alignment (LOA) Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Port Board (P4/8/16)
Probable Cause: Loss of Alignment (LOA) Element Type:
PTC (PTC)
Condition causing indication: LOA alarm will be active, if the differential delay between the fractions is too big and the vc4Virtual TTPs are without errors (no SQM alarm, no LOM alarm, no SSF alarm). Effect on service: Transmission is broken. Recommended action: None.
3AG 24197 ACAA - Ed. 04
103
5.7
Loss of Frame (LOF) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Loss of Frame (LOF) Element Type:
OpS (OSTTP), ElS (ESTTP)
Condition causing indication: Incoming STM Frame Bytes A1.A1.A1.A2.A2.A2 of the RSOH are wrong (not "XX.F6.F6.28.XX.XX"). Problem at connected SDH equipment or at the link from connected SDH equipment to NE. Effect on service: Transmission from connected SDH equipment to NE is broken. Recommended action: Repair connected SDH equipment / link or activate a path protection. According to ETS 300 417 and ITU G.783 all frame and pointer errors have to be reported in the adaption layer (CTP). In the information model the RSCTP is mapped to the physical interface (ESTTP/OSTTP). Therefore the LOF alarm is displayed:
104
-
in the Alarm Management on the RSCTP.
-
in the Transmission View/Port Details View on the ElS/OpS.
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
63 x 2Mbit/s Board
Probable Cause: Loss of Frame (LOF) Element Type:
E1 (E1 CTP), P12 (P12 CTP)
Condition causing indication: The incoming frame alignment signal (FAS) is not equal to 'X001.1011'. Problem at connected PDH equipment or at the link from connected PDH equipment to the NE. Effect on service: None. Recommended action: Repair connected PDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
105
5.8
Loss of MultiFrame (LOMF) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, Gigabit Ethernet Port Board (P4/8/18GE)
Probable Cause: Loss of MultiFrame (LOMF) Element Type:
modVc4 (VCĆ4 TTP), Vc4V (VCĆ4V TTP), Vc3V (VCĆ3V TTP)
Condition causing indication: The incoming POH H4 byte sequence is corrupted. The problem relates to the connected SDH equipment or the link from the connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to the NE is interrupted. Recommended action: Repair the connected SDH equipment/ link or activate path protection switching.
106
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
63 x 2Mbit/sBoard
Probable Cause: Loss of MultiFrame (LOMF) Element Type:
E1 (E1 CTP)
Condition causing indication: The incoming 2 Mbit/s signal is not correct. The CRCĆ4 subĆ frame is missing. Effect on service: Transmission is not affected. Recommended action: Repair the connected 2 Mbit/s equipment/ link.
3AG 24197 ACAA - Ed. 04
107
5.9
Loss of Pointer (LOP) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Loss of Pointer (LOP) Element Type:
MSP (MSP)
Condition causing indication: Problem at the internal link from connected OED to 1678MCC main shelf. Effect on service: Transmission from connected OED shelf to 1678MCC main shelf is broken. Recommended action: Repair the OED link or activate a path protection.
108
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Loss of Pointer (LOP) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP)
Condition causing indication: The incoming AUĆ4Ćpointer is in LOPĆstate (Annex C, G.783). Problem at connected SDH equipment or at the link from connected SDH equipment to NE. Effect on service: Transmission from connected SDH equipment to NE is broken. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
109
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Loss of Pointer (LOP) Element Type:
Tu3 (TUĆ3 CTP), Tu12 (TUĆ12 CTP)
Condition causing indication: The incoming TUĆ3/ TUĆ12Ćpointer is in LOPĆstate (Annex C, G.783). Problem at connected SDH equipment or at the link from connected SDH equipment to NE. Effect on service: Transmission from connected SDH equipment to NE is broken. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
110
3AG 24197 ACAA - Ed. 04
5.10
Loss of Signal (LOS) Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Board (GETHM)
Probable Cause: Loss of Signal (LOS) Element Type:
OpS (OSTTP), ElS (ESTTP)
Condition causing indication: There is no incoming signal. Problem at connected SDH equipment or at the link from connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to NE is broken. Recommended action: Repair connected SDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
111
Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Loss of Signal (LOS) Element Type:
MAU (MAU)
Condition causing indication: There is no incoming signal. Problem at connected GBE equipment or at the link from connected SDH equipment to the NE. Effect on service: Transmission from connected SDH equipment to NE is broken. Recommended action: Depending on the condition the has caused the alarm, perĆ form the following action: 1
Check the configuration of the MAU and make sure that the configuration type is the same as at the other end of the link (i.e. either both are configured as Manual or both are configured as Auto Negotiation)
2
Repair connected SDH equipment/ link or activate a path protection.
If the problem cannot be solved, call your Technical AssisĆ tance Center for help.
112
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board, 63 x 2Mbit/s Board
Probable Cause: Loss of Signal (LOS) Element Type:
P (PPITTP)
Condition causing indication: There is no incoming signal. Problem at connected PDH equipment or at the link from connected PDH equipment to NE. Effect on service: Transmission from connected PDH equipment to NE is broken. Recommended action: Repair connected PDH equipment/ link or activate a path protection.
3AG 24197 ACAA - Ed. 04
113
Event Type:
Communication alarm
Board Type:
Matrix 640GBIT/S Enh. (MX640GA), Matrix 320GBIT/S Enh. (MX320GA)
Probable Cause: Loss of Signal (LOS) Element Type:
sPPI (sPPI)
Condition causing indication: There is no incoming signal. Problem at connected PDH equipment or at the link from connected PDH equipment to NE. Effect on service: Transmission from connected PDH equipment to NE is broken. No signal at associated 1544kbps T6 timing referĆ ence input. Recommended action: Repair connected PDH equipment/ link.
114
3AG 24197 ACAA - Ed. 04
5.11
Payload Type Mismatch (PLTM) Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board, STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board,
Probable Cause: Payload Type Mismatch (PLTM) Element Type:
P4 (P4 CTP), modVC4 (VCĆ4 TTP)
Condition causing indication: There is a failure at the incoming C2Ćbyte (POH) which carĆ ries the Signal Label (SL). The SL of this NE (expected SL) does not match the SL sent by the connected SDH equipĆ ment (received SL). Effect on service: Transmission from connected SDH equipment to this NE is broken. Recommended action: Harmonize the expected Signal Label of this NE with the transmitted Signal Label of the relevant SDHĆNE for this path.
3AG 24197 ACAA - Ed. 04
115
Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Port Board (P4/8/18GE)
Probable Cause: Payload Type Mismatch (PLTM) Element Type:
Vc4XV (VCĆ4ĆXv TTP), Vc3XV (VCĆ3ĆXv TTP)
Condition causing indication: There is a failure at the incoming C2Ćbyte (POH) which carĆ ries the Signal Label (SL). The SL of this NE (expected SL) does not match the SL sent by the connected SDH equipĆ ment (received SL). Effect on service: Transmission in downstream direction is interrupted. Recommended action: Harmonize the expected Signal Label in the NE with the transmitted Signal Label of the relevant SDHĆNE for this path.
116
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
63 x 2 Mbit/s Board
Probable Cause: Payload Type Mismatch (PLTM) Element Type:
P12 (P12 CTP)
Condition causing indication: There is a failure at the incoming V5Ćbyte (POH) which carĆ ries the Signal Label (SL). The SL of this NE (expected SL) does not match the SL sent by the connected SDH equipĆ ment (received SL). Effect on service: Transmission in downstream direction is interrupted. Recommended action: Harmonize the expected Signal Label in the NE with the transmitted Signal Label of the relevant SDHĆNE for this path.
3AG 24197 ACAA - Ed. 04
117
5.12
Remote Defect Indication (RDI) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Remote Defect Indication (RDI) Element Type:
MST (MSTTP), MSP (MSP)
Condition causing indication: The incoming MSOH (K2ĆByte) indicates a problem at the connected SDH equipment or at the link from the conĆ nected SDH equipment to this NE. Effect on service: None. Recommended action: Repair the link or activate path protection switching. Check transmission signal on TxĆside.
118
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, 4 x 140/STMĆ1O/E Board
Probable Cause: Remote Defect Indication (RDI) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP) with POM/SUT on, modVc4 (VCĆ4 TTP)
Condition causing indication: Bit 5 of the incoming G1 byte (POH) is 1. The problem is at this NE or the link from this NE to the connected SDH equipment. Effect on service: None. Recommended action: Repair the NE/ link or activate path protection switching.
3AG 24197 ACAA - Ed. 04
119
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, 63 x 2Mbit/s Board
Probable Cause: Remote Defect Indication (RDI) Element Type:
Tu12 (TUĆ12 CTP) with POM/SUT on, Vc12 (VCĆ12 TTP)
Condition causing indication: Bit 8 of the incoming V5 byte (POH) is 1. The problem is at this NE or the link from this NE to the connected SDH equipment. Effect on service: None. Recommended action: Repair the NE/ link or activate path protection switching.
120
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board, Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Remote Defect Indication (RDI) Element Type:
Vc3 (VCĆ3 TTP), Vc3V (VCĆ3V TTP), Vc4 (VCĆ4 TTP), Vc4V (VCĆ4V TTP),
Condition causing indication: Bit 5 of the incoming G1 byte is equal to 1. The problem is at the NE or the link from the NE to the connected SDH equipment. Effect on service: None. Recommended action: Repair the NE/ link or activate path protection switching. Check transmission signal on TxĆside.
3AG 24197 ACAA - Ed. 04
121
Event Type:
Communication alarm
Board Type:
63 x 2 Mbit/s Board
Probable Cause: Remote Defect Indication (RDI) Element Type:
E1 (E1 CTP), P12 (P12 CTP)
Condition causing indication: The D bit received (urgent remote alarm) was detected as `1'. The problem is at the NE or the link from the NE to the connected PDH equipment. Effect on service: None Recommended action: Check the relevant NE port/ link or activate a path protecĆ tion.
122
3AG 24197 ACAA - Ed. 04
5.13
Sequence (Number) Mismatch (SQM) Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Sequence (Number) Mismatch (SQM) Element Type:
Vc4V (VCĆ4V TTP), Vc3V (VCĆ3V TTP)
In case of mismatch between received and expected fraction number an SQM alarm is raised. This indicates a wrong configuration in the network. Effect on service: Transmission is broken. Recommended action: Correct the pathes of the mismatching Signal fractions in the network. The SQM alarm can only occur, if LCAS is disabled.
3AG 24197 ACAA - Ed. 04
123
5.14
Server Signal Fail (SSF) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Server Signal Fail (SSF) Element Type:
RST (RSTTP) MST (MSTTP), MSP (MSP), modVc4 (VCĆ4 TTP)
Condition causing indication: All lower order TPs report an SSF alarm, if a higher order alarm is active. Effect on service: Transmission from connected SDH equipment to this NE is broken. Recommended action: Repair connected SDH equipment/ link.
There are the follwing restrictions regarding SSF in OEDs: - Disabling of LOS, LOF and TIM in OED 1662 or 1670 also disables SSF for MST and MSP. - SSF for MST in OED 1670 does not trigger restoration.
124
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Server Signal Fail (SSF) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP), Tu12 (TUĆ12 CTP) with POM/SUT before matrix on
Condition causing indication: All lower order TPs report an SSF alarm if a higher order alarm is active. Effect on service: Transmission from connected SDH equipment to this NE is broken. Recommended action: Repair connected SDH equipment/ link.
3AG 24197 ACAA - Ed. 04
125
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Server Signal Fail (SSF) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP), Tu12 (TUĆ12 CTP) with POM/SUT after matrix on
Condition causing indication: The selected matrix copy provides an AIS. Effect on service: Transmission from connected SDH equipment to this NE is broken. Recommended action: Repair connected SDH equipment/ link .
126
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Server Signal Fail (SSF) Element Type:
Vc3XV (VCĆ3ĆXv TTP), Vc3V (VCĆ3V TTP), Vc4XV (VCĆ4ĆXv TTP), Vc4V (VCĆ4V TTP),
Condition causing indication: SSF alarm is raised if the virtual PTC indicates SSF via conĆ sequent actions. A primary alarm is active on one or more of the Server TPs. Effect on service: Traffic is not affected, because in the current Release the next downstream function is not informed about the sigĆ nal fail" condition (no AIS insertion). Recommended action: Perform the recommended action for the primary alarm(s).
3AG 24197 ACAA - Ed. 04
127
Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board, 63 x 2Mbit/s Board
Probable Cause: Server Signal Fail (SSF) Element Type:
Vc4 (VCĆ4 TTP), E1 (E1 CTP), P12 (P12 CTP), Vc12 (VCĆ12 TTP)
Condition causing indication: The selected timing reference is lost. Effect on service: Transmission from connected SDH equipment to this NE is broken. Recommended action: Repair connected SDH equipment / link.
128
3AG 24197 ACAA - Ed. 04
5.15
Trace Identifier Mismatch (TIM) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Trace Identifier Mismatch (TIM) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP) with POM/SUT on
Condition causing indication: There is a failure at the incoming J1Ćbyte (POH) which carĆ ries the Trace Identifier (TI). The TI of this NE (expected TI) does not match the TI of the connected SDH equipment (received TI). Effect on service: No effect on transmission. Recommended action: Harmonize the expected TI in this NE with the transmitted TI of the relevant SDHĆNE for this path.
3AG 24197 ACAA - Ed. 04
129
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Trace Identifier Mismatch (TIM) Element Type:
RST (RSTTP), modVc4 (VCĆ4 TTP)
Condition causing indication: There is a failure at the incoming J0/J1Ćbyte (SOH/POH) which carries the Trace Identifier TI. THe TI of this NE (exĆ pected TI) does not match the TI of the connected SDH equipment (received TI). Effect on service: Transmission from connected SDH equipment to this NE is broken. -
AIS is sent to connected SDH equipment.
-
Higher order RDI is sent to connected SDH equipment.
Recommended action: Harmonize the expected TI in this NE with the transmitted TI of the relevant SDHĆNE for this path.
130
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, 63 x 2Mbit/s Board
Probable Cause: Trace Identifier Mismatch (TIM) Element Type:
Tu12 (TUĆ3 CTP) with POM/SUT on, Vc12 (VC12 TTP)
Condition causing indication: There is a failure at the incoming J2Ćbyte (POH) which carĆ ries the Trace Identifier (TI). The TI of this NE (expected TI) does not match the TI of the connected SDH equipment (received TI). Effect on service: No effect on transmission. Recommended action: Harmonize the expected TI in this NE with the transmitted TI of the relevant SDHĆNE for this path.
3AG 24197 ACAA - Ed. 04
131
Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board,
Probable Cause: Trace Identifier Mismatch (TIM) Element Type:
Vc4 (VCĆ4 TTP)
Condition causing indication: There is a failure at the incoming J1Ćbyte which carries the Trace Identifier (TI). The TI at this NE (expected TI) does not match the TI of the connected SDH equipment (reĆ ceived TI). Effect on service: Transmission in downstream direction is interrupted. -
140 Mbit/sĆAIS is sent to connected PDH equipment
-
Higher order RDI is sent to connected SDH equipment
Recommended action: Harmonize the expected TI in the NE with the transmitted TI of the relevant SDHĆNE for this path.
132
3AG 24197 ACAA - Ed. 04
5.16
Transmitter Degraded (TD) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Transmitter Degraded (TD) Element Type:
OpS (OSTTP)
Condition causing indication: Laser is degraded. Effect on service: Bit errors may occur. Recommended action: Check state of the laser on I/O board and replace the board (. Maintenance Handbook).
3AG 24197 ACAA - Ed. 04
133
5.17
Transmitter Failure (TF) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Transmitter Failure (TF) Element Type:
OpS (OSTTP)
Condition causing indication: Laser has failed. Effect on service: Transmission is broken. Recommended action: Replace the I/O board (. Maintenance Handbook).
134
3AG 24197 ACAA - Ed. 04
5.18
Unavailable Time (UAT) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Unavailable Time ( UAT) Element Type:
RST (RSTTP), MST (MSTTP) modVc4 (VcĆ4 TTP) with Performance Monitoring activated
Condition causing indication: Unavailable Time was detected. UAT indicates UAS. Effect on service: Bit errors or alarms at the transmission between connected SDH equipment and this NE. Recommended action: Repair connected equipment/ link or activate path protecĆ tion.
3AG 24197 ACAA - Ed. 04
135
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Unavailable Time (UAT) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP), Tu12 (TUĆ12 CTP), with POM/SUT enabled and and Performance Monitoring activated
Condition causing indication: Unavailable Time was detected. UAT indicates UAS. Effect on service: High bit errors or alarms at the transmission between this NE and connected SDH equipment. Recommended action: Repair connected equipment/ link or activate path protecĆ tion.
136
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
4 x 140/STM-1O/E Board, 63 x 2Mbit/s Board Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Unavailable Time ( UAT) Element Type:
Vc4 (VCĆ4 TTP), E1 (E1 CTP), P12 (P12 CTP), Vc12 (VCĆ12 TTP), Vc3V (VCĆ3V TTP), Vc4V (VCĆ4V TTP), with Performance Monitoring activated
Condition causing indication: Unavailable Time was detected. UAT indicates UAS. Effect on service: Bit errors or alarms at the transmission between connected PDH equipment and this NE. Recommended action: Repair connected equipment/ link or activate path protecĆ tion.
3AG 24197 ACAA - Ed. 04
137
5.19
Underlying Resource Unavailable (URU) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board, 4 x 140/STMĆ1O/E Board, 63 x 2Mbit/s Board, Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Underlying Resource Unavailable (URU) Element Type:
OpS (OSTTP), ElS (ESTTP), P (PPITTP), MAU (MAU)
Condition causing indication: -
problem with original board/module and protection board/module (equipment protection was not possible), or
-
both matrix boards are missing or faulty.
Effect on service: Transmission interrupted. Recommended action: Replace the board (. Maintenance Handbook).
138
3AG 24197 ACAA - Ed. 04
5.20
Unequipped (U) Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STMĆ64 Board
Probable Cause: Unequipped (U) Element Type:
Au4P (AUĆ4 CTP), Au3P (AUĆ3 CTP), Au4/4c (AUĆ4Ć4c CTP), Au4/16c (AUĆ4Ć16c CTP), Au4/64c (AUĆ4Ć64c CTP), Tu3 (TUĆ3 CTP), with POM/SUT before and after matrix enabled, modVc4 (VCĆ4 TTP)
Condition causing indication: There is a failure at the incoming C2Ćbyte (POH) which carĆ ries the Signal Label (SL). The received SL is "00". Effect on service: For modVc4 only: Transmission from connected SDH equipment to the NE is interrupted. Recommended action: Harmonize the expected SL in this NE with the transmitted SL of the relevant connected SDH equipment for this path.
3AG 24197 ACAA - Ed. 04
139
Event Type:
Communication alarm
Board Type:
STMĆ1/STMĆ4/STMĆ16/STM-64 Board
Probable Cause: Unequipped (U) Element Type:
Tu12 (TUĆ12 CTP), with POM/SUT before and after matrix enabled
Condition causing indication: There is a failure at the incoming V5Ćbyte (POH) which carĆ ries the Signal Label (SL). The received SL is "00". Effect on service: No effect on transmission. Recommended action: Harmonize the expected SL in this NE with the transmitted SL of the relevant connected SDH equipment for this path.
140
3AG 24197 ACAA - Ed. 04
Event Type:
Communication alarm
Board Type:
4 x 140/STMĆ1O/E Board, Gigabit Ethernet Port Board (P4/8/16GE)
Probable Cause: Unequipped (U) Element Type:
Vc3 (VCĆ3 TTP), Vc3V (VCĆ3V TTP), Vc4 (VCĆ4 TTP), Vc4V (VCĆ4V TTP)
Condition causing indication: The incoming C2Ćbyte carries the Signal Label (SL) 0", alĆ though a different SL is expected. Effect on service: Transmission in downstream direction is interrupted. - 140Mbit/sĆAIS is sent to connected PDH equipment - Higher order RDI is sent to connected SDH equipment Recommended action: Harmonize the expected SL in this NE with the transmitted SL of the relevant SDH equipment for this path.
3AG 24197 ACAA - Ed. 04
141
Event Type:
Communication alarm
Board Type:
63 x 2Mbit/s Board
Probable Cause: Unequipped (U) Element Type:
Vc12 (VCĆ12 TTP)
Condition causing indication: The incoming V5Ćbyte (POH) carries the Signal Label (SL) 0", although a different SL is expected. Effect on service: Transmission in downstream direction is interrupted. Recommended action: Harmonize the expected SL in this NE with the transmitted SL of the relevant connected SDH equipment for this path.
142
3AG 24197 ACAA - Ed. 04
3AG 24197 ACAA - Ed. 04
143
6
Quality of Service Alarms
FriendlyName Port
STMĆ1/STMĆ4/ STMĆ16/STMĆ64
Gigabit Ethernet 140MB 2MB ą*)
Counted Primitives
Element Type
Alarm Type *)
RST
(1)
B1 Block Errors
MST
(1) + (2)
B2 Block Errors
Au4P, Au3P, Au4Ć4c, Au4Ć16c, Au4Ć64c, Tu3
(1) + (2) + (3)
B3 Block Errors
ModVc4
(1) + (2)
B3 Block Errors
Tu12
(1) + (2) + (3)
BIPĆ2 Block Errors
Vc4V
(1) + (2)
B3 Block Errors
Vc3V
(1) + (2)
B3 Block Errors
Vc4
(1) + (2)
B3 Block Errors
E2
(1)
FAWĆ2Mbit/s or CRCĆ4
P12
(1)
CRCĆ4
Vc12
(1) + (2)
BIPĆ2 Block Errors
For an explanation of the alarm type see below
Table 13
Correlation of Element Type and Alarm Type with Threshold Alarms All quality of service alarms shown in the alarm list (see Chapter 3, Table 12 ) are threshold alarms. As a precondiĆ tion for reporting threshold alarms, performance monitorĆ ing has to be enabled for the corresponding TPs. Threshold alarms (15min and 24h) are reported if the preset threshĆ olds are exceeded. Threshold alarms (15 min.) are automatically cleared after one error free 15Ćmin.Ćinterval. Threshold alarms of 24ĆhĆ intervals are automatically cleared after midnight or have to be cleared by the user. Alarm type explanation: The alarm type is part of the Friendly Name and indicates the assignment of the threshold to near or far end attribĆ utes and to a granulatity period (15 min. or 24h). Threshold alarms of the following types are reported in the alarm list if performance monitoring is enabled for the corĆ responding element:
3AG 24197 ACAA - Ed. 04
145
(1)
Near End
NTR15
ThReshold 15 min.
N1d
threshold 24 h
(2)
Far End
FTR15
ThReshold 15 min.
F1d
threshold 24 h
(3)
Trail Monitor (Near and FarEnd)
TMe
after Matrix (egress)
TMi
before Matrix (ingress)
SUExM
Supervisory Unequiped Termination (SUT)
Table 14
146
Threshold Alarm Types
3AG 24197 ACAA - Ed. 04
The different alarm types that are shown in the alarm list and the correlated element types are listed in Table 13 . Probable cause, condition causing indication, effect on serĆ vice and recommended action of all threshold alarms correĆ spond with the description given below. All threshold alarms can be described by the following scheme: Event Type:
Quality of service alarm
Port Type:
see Table 13
Probable Cause: Threshold Crossed Element Type:
see Table 13 and Table 14
Condition causing indication: The preset threshold was exceeded. Effect on service: The received signal is not error free. Recommended action: Please check the equipment on the far end and the link beĆ tween far end and near end.
3AG 24197 ACAA - Ed. 04
147
148
3AG 24197 ACAA - Ed. 04