ZXSDR eNodeB Hardware Structure ZTE University
Objectives
After this course, you will be able to:
Know the ZXSDR eNodeB highlights
Master the eNodeB technical specification
Understand the eNodeB physical hardware
Master the eNodeB network architecture and configuration
Know the eNodeB maintenance method
Contents
eNodeB Overview
ZXSDR B8200 L200 Hardware Structure
ZXSDR R8882 Hardware Structure
ZXSDR eNodeB Maintenance
LTE Base Station Family Macro indoor base station
BS8800
Macro outdoor base station
BS8900A
BBU
B8200
RRU
R8882/R8862/R8972/R8964
Pico
BS8912/BS8922
Femto
BS8102
Qcell
R8108
© ZTE Corporation. All rights reserved
eNodeB Location in the Network Mobility Management Entity Serving Gateway
MME/S-GW
MME/S-GW
EPC
S1
EPS
Interface between MME/SGW & eNodeB
X2 eNB
E-UTRAN eNB
X2
X2 eNB
UE
Interface between eNodeBs
eNodeB=BBU+RRU Node B © ZTE Corporation. All rights reserved
RNC
eNodeB
eNodeB System Structure: BBU + RRU
© ZTE Corporation. All rights reserved
ZXSDR eNodeB Functionality
Control Plane S1/X2 interface management
User Plane
Voice business
Cell management
UE management
Data business
System information broadcast Mobility management
© ZTE Corporation. All rights reserved
Image business
ZXSDR eNodeB Highlights
Large capacity Mature and stable performance Multi-standard and smooth evolution
Compact design and easy deployment All-IP architecture
© ZTE Corporation. All rights reserved
Network Architecture
© ZTE Corporation. All rights reserved
ZTE Unified Radio Sub-System Platform OneNetwork Target GSM/EDGE
UMTS/HSPA
TD-SCDMA
CDMA2000
WiMAX
LTE
ZTE Universal SDR Platform
GSM/EDGE UMTS/HSPA LTE
Distributed
Integrated
Universal RRU
RRU
RSU
Features MicroTCA architecture Multi-Standard support Baseband sharing and
BBU
software configurable RRU sharing and software
BBU
configurable
Future-Proof Platform with Smooth Evolution Support © ZTE Corporation. All rights reserved
LTE Product Portfolio INTEGRATED
Soft defined radio 2xMCPA, MIMO
Femto eNB BS8210 Multi-mode eNB Multi-mode eNB Outdoor BS8900 Indoor BS8800
2x40 W TOC power, 35% power efficiency for LTE
BBU+RRU
All-IP transmission, provides IP over E1/STM-1 interface
Multi-mode BBU Multi-mode BBU Multi-mode RRU R8880/R8882 Outdoor B8201 Indoor B8200
ZTE SDR PRODUCTS ADAPT TO TECHNOLOGY DIVERSITIES HSPA
© ZTE Corporation. All rights reserved
HSPA+
LTE
Unified O&M for simultaneous running RATs
TCO reduction comparing with traditional solution
SDR Benefits Clearer and Simpler Network
Lower Total Cost of
Lower Investment
Ownership (TCO)
Risk
© ZTE Corporation. All rights reserved
Contents
eNodeB Overview
ZXSDR B8200 L200 Hardware Structure
ZXSDR R8882 Hardware Structure
ZXSDR eNodeB Maintenance
Hardware Structure
The ZXSDR B8200 TL200 is designed on the basis of MicroTCA (also known as uTCA—a flexible common
platform), which is easy to be expanded.
© ZTE Corporation. All rights reserved
BBU Technical Specifications Index
Specification
Dimension
88.4 mm x 482.6 mm x 197 mm (Height x Width x Depth)
Weight
• Typical configuration: 5.25 kg • Maximal configuration: 7.5 kg
Power supply
–48 V DC (range: –57 V to –40 V)
Grounding
≤5Ω The ground resistance can be lower than 10 Ω in areas where the number of thunderstorm days per year is less than 20.
Operating temperature
–20 ˚C to +50 ˚C
Operating humidity
5% –95%
– Typical configuration: 1 x PM + 1 x SA + 1 x BPL + 1 x CC + 1 x FAM
© ZTE Corporation. All rights reserved
Capacity Specifications Board Configuration
Site Type
Capacity
Number of Users in RRC_Connect ed state
3 x 20 MHz cells (2T2R/2T4R)
DL/UL: 450 Mbps/225 Mbps
3600
6 x 20 MHz cells (2T2R/2T4R)
DL/UL: 600 Mbps/300 Mbps
3600
3 x 20 MHz cells (4T4R)
DL/UL: 600 Mbps/300 Mbps
3600
9 x 20 MHz cells (2T2R/2T4R)
DL/UL: 900 Mbps/600 Mbps
7200
12 x 20 MHz cells (2T2R/2T4R)
DL/UL: 900 Mbps/600 Mbps
7200
3xBPL1/BPN0
18 x 20 MHz cells (2T2R/2T4R)
DL/UL: 900 Mbps/900 Mbps
10800
BPL1A/BPN0A
3 x 20 MHz cells (2T2R/2T4R)
DL/UL: 450 Mbps/225 Mbps
3600
BPL1/BPN0
3 x 20 MHz cells (2T2R/2T4R)
DL/UL: 450 Mbps/225 Mbps
3600
6 x 20 MHz cells (2T2R/2T4R)
DL/UL: 600 Mbps/300 Mbps
3600
3 x 20 MHz cells (4T4R)
DL/UL: 600 Mbps/300 Mbps
3600
9 x 20 MHz cells (2T2R/2T4R)
DL/UL: 1200 Mbps/600 Mbps
7200
12 x 20 MHz cells (2T2R/2T4R)
DL/UL: 1200 Mbps/600 Mbps
7200
3xBPL1/BPN0
18 x 20 MHz cells (2T2R/2T4R)
DL/UL: 1800 Mbps/900 Mbps
10800
3xBPN2
36 x 20 MHz cells (2T2R/2T4R)
DL/UL: 3600 Mbps/1800 Mbps
10800
CC Board Type
BPL Board Type
CC16B
BPL1/BPN0
2xBPL1/BPN0
CCE1
2xBPL1/BPN0
© ZTE Corporation. All rights reserved
Power Consumption Specifications (Typical Power Consumption at Normal Temperature) Item
Specification
3 cells/1 BPL1
120 W
6 cells/1 BPN0
90 W
24 carrier frequencies + 3 carrier sectors (128 CEs) + 6 cells/ 1BPN2
125 W
12 carrier frequencies + 6 carrier sectors (256 CEs) + 6 cells/ 1BPN2
125 W
Item
Specification
Power consumption (typical configuration at normal temperature)
80 W
– Typical configuration: 1 x PM + 1 x SA + 1 x BPN0 + 1 x CC16B + 1 x FAM
© ZTE Corporation. All rights reserved
ZXSDR B8200 TL200 Boards Overview Name
Slot
Configuration Principle
CC
1–2
Two CCs are required for the active/standby configuration.
BPL1/BPL1A/BP N0/BPN0A/BN P2
3–8
The baseband processing boards are configured in accordance with the required processing capability.
SA
13
PM
14–15
• Two PMs are required when more than one baseband processing boards are configured. • Two PMs are required when two power supplies are operating in active/standby mode.
FAM
16
FS
3–4
Optional. The FS board is required for the multi-mode configuration.
SE
5
Optional. One SE is required for the configuration of two RS232/RS485 interfaces and 16 dry contacts, and a 0.5U blank panel is also required in the same slot.
UES
Optional. The UES boards are configured in accordance with the actual Ethernet requirement. • Supporting the SyncE function: slot 2 and slot 5 • Not supporting the SyncE function: slot 1 to slot 8
UCI
3–8
© ZTE Corporation. All rights reserved
Optional. The UCI boards are configured in accordance with the clock configuration.
ZXSDR B8200 Hardware and Interfaces
No.
Interface
Module
1
DEBUG/CAS-/LMT
CC
2
ETH0
CC
S1/X2 interface, GE/FE self-adaptive electrical interface
3
TX/RX
CC
S1/X2 interface, GE/FE optical interface
4
USB
CC
Data updating
5
REF
CC
External GPS antenna interface
6
EXT
CC
External communication interface to connect external receiver
7
SA Interface
SA/SE
RS485/232 interface, 6+2 dry contact interfaces
8
-48V/-48VRTN
PM
Input power of –48 V
9
MON
PM
10
TX0 /RX0–TX2/RX2
BPL
Debugging interface, RS232 interface Three 2.4576G/4.9152G OBRI/ Ir optical interfaces, used for connecting RRU
© ZTE Corporation. All rights reserved
Description Cascading, debugging or local maintenance interface, GE/FE selfadaptive electrical interface
CC: Control and Clock Board
Interface (CC16B)
Description
ETH0
Used as an S1/X2 Ethernet interface. It is a GE/FE adaptive electrical interface.
DEBUG/CAS/LMT
Used as an Ethernet interface for cascading, debugging, and local maintenance. It is a GE/FE adaptive electrical interface.
TX/RX
Used as an S1/X2 Ethernet optical interface. It is a GE/FE optical interface, and cannot be used at the same time when the ETH0 interface is used. The 1.25 Gbps optical module must be used.
EXT
HDMI interface. It provides one 1PPS+TOD input and one output, and outputs testing clock signals.
REF
External GPS antenna interface.
USB
Serial interface for data update.
© ZTE Corporation. All rights reserved
CC: Control and Clock Board
Interface (CCE1)
Description
ETH0
Used as an S1/X2 Ethernet interface. It is a GE/FE adaptive electrical interface.
ETH1
Used as an Ethernet interface for cascading. It is a GE/FE adaptive electrical interface.
DEBUG/LMT
Used as an Ethernet interface for debugging and local maintenance. It is a GE/FE adaptive electrical interface.
TX ETH2 RX
Used as an S1/X2 optical interface. It is a 1000/10000 Mbps adaptive optical interface.
TX ETH3 RX
Used as an S1/X2 optical interface. It is a 1000/10000 Mbps adaptive optical interface.
EXT
HDMI interface. It provides one 1PPS+TOD input and one output, and outputs testing clock signals.
REF
External GPS antenna interface.
USB
Serial interface for data update.
© ZTE Corporation. All rights reserved
CC Module Indicator—1 Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal.
ALM
Red
Alarm indicator
• Off: There is no hardware fault. • On: There is a hardware alarm reported.
MS
Green
Base station state • Active/standby state indication indicator On: The board is in active state. Off: The board is in standby state. • USB state commissioning indication Flashing slowly seven times (0.3 s on and 0.3 s off, 4.2 seconds in total): A UKEY is inserted. Off: The USB check is not passed. Flashing quickly (70 ms on, 70 ms off): The USB commissioning is being implemented. Flashing slowly (0.3 s on, 0.3 s off): The USB commissioning is completed. • System self-test state indication Flashing quickly (70 ms on, 70 ms off): The system is performing self-test. Flashing slowly (0.3 s on, 0.3 s off): The system self-test is completed.
© ZTE Corporation. All rights reserved
CC Module Indicator—2 Name
Color Meaning
Description
REF
Green Reference clock source operating state indicator
• On: The reference clock source is not operating properly. • Off: The reference clock source is not configured.
• Flashing slowly (0.3 s on, 0.3 s off): The reference clock source is operating properly.
ETH0
Green External • On: The Ethernet cable is connected properly. Ethernet • Flashing: Data is being transmitted or received. interface (ABIS/IUB) state • Off: The Ethernet cable is not connected. indicator
ETH1
Green Debug/LMT/CA • On: The Ethernet cable is connected properly. S state indicator • Flashing: Data is being transceived. • Off: The Ethernet cable is not connected.
E0S-E3S
Green E1 indicator
HS
-
Ethernet interface indicator
Green -
-
Reserved • Left indicator On: The interface is connected successfully. Off: The interface is not connected. • Right indicator Flashing: Data is being transceived. Off: Data is not being transceived.
© ZTE Corporation. All rights reserved
CC: Control and Clock Module
Button
Button Name
Description
M/S
Indicates the active/standby switch.
RST
Indicates the reset switch.
© ZTE Corporation. All rights reserved
FS: Fabric Switch Module FS Board Type
Supported Wireless System
CPRI Interface Rate (Gbps)
FS5
GSM/UMTS/LTE (single-mode or multi-mode)
1.2288/2.4576/ 3.072/6.144
CR0
LTE (single-mode if there is a cloud radio requirement)
1.2288/2.4576/ 3.072/6.144/ 9.8304
FS5 Panel
CR0 Panel
© ZTE Corporation. All rights reserved
FS Module Indicator Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal.
ALM
Red
Alarm indicator
• On: There is a hardware alarm reported.
• Off: There is no hardware fault. CST
Green
Optical interface state indicator
Reserved
SCS
Green
Board clock state indicator
• On: Fsync is abnormal. • Flashing slowly (0.3 s on, 0.3 s off): The clock is operating properly. • Off: The 50CHIP clock is not operating properly.
FLS
RLS
Green
Green
Forward baseband link frame lock indicator
• On: The TDM channel state is not normal.
Optical interface backward link frame lock indicator
• Flashing according to time (the indicator flashes in an 18-second cycle, it sequentially indicates the backward baseband link frame lock state of the six optical interfaces every three seconds): Flashing once ~ six times : The backward link of the 0th~5th optical interface is normal.
• Flashing slowly (0.3 s on, 0.3 s off): The TDM channel state is normal. • Off: The TDM channel is not configured.
• Off: The optical link is not configured. HS
-
-
© ZTE Corporation. All rights reserved
Reserved
Performance Indexes for LTE BPL Boards Index Type
BPL1A
BPL1
BPN0A
BPN0
BPN2
Number of CPRI optical interfaces
3 pairs
3 pairs
6 pairs
6 pairs
6 pairs
Number of users connected to the RRC
3600
3600
3600
3600
7200
Number of cells (20 MHz, 2T2R/2T4R)
3
6
3
6
12
Number of cells (20 MHz, 4T4R)
N/A
3
N/A
3
6
Data throughput
DL 450 Mbps/UL 225 Mbps
DL 600 Mbps/ UL 300 Mbps
DL 450 Mbps/ UL 225 Mbps
DL 600 Mbps/ UL 300 Mbps
DL 1200 Mbps/ UL 600 Mbps
© ZTE Corporation. All rights reserved
BPL Panel and Interfaces BPL1/BPL1A Panel
BPN0/BPN0A Panel
Notes: BPN0A has the same panel as BPN0, but only TX0 RX0 to TX2 RX2 CPRI optical interfaces are available on BPN0A.
BPN2 Panel
Board
Interface
Description
BPL1/BPL1A/ BPN0A
TX0 RX0 to TX2 RX2
Three pairs of CPRI optical interfaces/electrical interfaces, used to connect the BBU to RSU/RRUs.
BPN0/BPN2
TX0/RX0 to TX5/RX5
Six pairs of CPRI optical interfaces/electrical interfaces, used to connect the BBU to RSU/RRUs.
© ZTE Corporation. All rights reserved
Performance Indexes for LTE Baseband Processing Boards Index Type
BPL1A
BPL1
BPN0A
BPN0
BPN2
Number of CPRI optical interfaces
3 pairs
3 pairs
6 pairs
6 pairs
6 pairs
Number of users connected to the RRC
3600
3600
3600
3600
7200
Number of cells (20 MHz, 2T2R/2T4R)
3
6
3
6
12
Number of cells (20 MHz, 4T4R)
N/A
3
N/A
3
6
Data throughput
DL 450 Mbps/UL 225 Mbps
DL 600 Mbps/ UL 300 Mbps
DL 450 Mbps/ UL 225 Mbps
DL 600 Mbps/ UL 300 Mbps
DL 1200 Mbps/ UL 600 Mbps
© ZTE Corporation. All rights reserved
BPL Indicators Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• On: The board is loading the software version. • Off: The power supply is not operating properly. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal.
ALM
OF0– OF5
Red
Green
Hardware fault indicator
• On: The hardware is faulty.
Optical interface link state indicator
• On: The optical interface link is not operating properly.
• Off: There is no hardware fault.
• Flashing slowly (0.3 s on, 0.3 s off): The optical interface is communicating properly. • Off: The optical module is not in position or the optical module does not receive any optical signal.
CST
-
-
Reserved
HS
-
-
Reserved
BLS
-
-
Reserved
BSA
-
-
Reserved
LNK
-
-
Reserved
© ZTE Corporation. All rights reserved
SA: Site Alarm Module
Interface
Description RS485/232 interface, 6+2 dry contact interfaces (six input lines, two 2-way interfaces)
© ZTE Corporation. All rights reserved
SA Module Indicator Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal.
ALM
HS
Red
-
© ZTE Corporation. All rights reserved
Alarm indicator
• Off: There is no hardware fault.
-
Reserved
• On: There is a hardware alarm reported.
PM: Power Module
PM3
PM4
Type
Description
PM3
Supports 300 W power output and 10-channel power outputs.
PM4
As a high-power power board, PM4 supports 400 W power output and 10-channel power outputs.
Interface
Description
MON
Debugging interface, RS232 interface
–48V/–48VRTN
–48V input/–48V GND input
© ZTE Corporation. All rights reserved
PM Module Indicators Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly.
• Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal. ALM
Red
PWR (PM3 panel)
Blue
HS (PM4 panel)
-
© ZTE Corporation. All rights reserved
Alarm indicator
• Off: There is no hardware fault.
Power supply state indicator
• Off: The 12 V power supply is not operating properly.
-
Reserved
• On: There is a hardware alarm reported.
• On: The 12 V power supply is operating properly.
FM: Fan Module
Function:
Provides the fan control function and interface.
Provides a temperature sensor to detect
temperature of air intake.
Displays the fan status.
© ZTE Corporation. All rights reserved
FM Module Indicators
Name
Color
Meaning
Description
RUN
Green
Operatin g state indicator
• Off: The power supply is not operating properly. • Flashing slowly (0.3 s on, 0.3 s off): The module is operating properly.
• Flashing quickly (70 ms on, 70 ms off): The external environment is not normal. ALM
Red
© ZTE Corporation. All rights reserved
Alarm indicator
• Off: There is no hardware fault. • On: The fan is faulty.
UES: Universal Ethernet Switch Board
The UES board provides the Ethernet synchronization function, and can operate as a layer-2 switch. When operating as an Ethernet switch, this board converges the data of other BBUs on its physical site, meaning
that there are multiple BBUs on a single physical site.
Interface
Description
X1–X2
Electrical interfaces, fixedly used as cascading interfaces.
X3/ULPINK
Electrical interface, used as a cascading interface or an uplink interface.
UPLINK
Electrical interface or optical interface, fixedly used as a cascading interface.
X4/UPLINK
Optical interface, used as a cascading interface or an uplink interface.
© ZTE Corporation. All rights reserved
UES Indicators Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version. • Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal.
ALM
Red
Alarm indicator
• Off: There is no hardware fault. • On: There is a hardware alarm reported.
SCS
Green
1588 function indicator
• On: The 1588 protocol is supported. • Off: The 1588 protocol is not supported (for the time being).
ETS
Green
Clock state indicator
• Flashing slowly (0.3 s on, 0.3 s off): The PLL is locked, and the synchronous Ethernet clock is operating properly. • Off: Not defined. By default, the ETS indicator is not lit. • On: The PLL loses lock and the synchronous Ethernet clock is not operating properly.
OP1
Green
Opticalinterface X4/UPLINK link state indicator
• On: The link is operating properly but has no data being transceived. • Flashing: The optical communication is normal. • Off: The link is interrupted.
OP2
Green
Opticalinterface UPLINK link state indicator
• On: The link is operating properly but has no data being transceived. • Flashing: The optical communication is normal. • Off: The link is interrupted.
HS
-
-
Reserved
© ZTE Corporation. All rights reserved
UCI: Universal Clock Interface Module
The Universal Clock Interface (UCI) board is a RGPS interface board. The UCI board receives, converts, and transfers BBU clocks.
Interface
Description
TX RX
125 Mbps optical interface. Used to connect to an external RGPS device to get input signals.
EXT
HDMI interface. Used for providing one channel of 1PPS+TOD clock signals to the CC board in the shelf.
REF
Reserved.
DLINK0
HDMI interface. Used for providing two channels of output 1PPS+TOD clock signals to the CC board in other shelves.
DLINK1
HDMI interface. Used for providing two channels of output 1PPS+TOD clock signals to the CC board in other shelves.
© ZTE Corporation. All rights reserved
UCI Module Indicators Name
Color
Meaning
Description
RUN
Green
Operating state indicator
• Off: The power supply is not operating properly. • On: The board is loading the software version.
• Flashing slowly (0.3 s on, 0.3 s off): The board is operating properly. • Flashing quickly (70 ms on, 70 ms off): The external communication of the board is not normal. ALM
Red
Alarm indicator
• Off: There is no hardware fault.
• On: There is a hardware alarm reported.
OPT
-
-
Reserved
P&T
-
-
Reserved
RMD
-
-
Reserved
LINK
-
-
Reserved
HS
-
-
Reserved
© ZTE Corporation. All rights reserved
Typical Configuration Item
Configuration
Description
CC
1
Control and clock board
BPL
1
Baseband processing for LTE
PM
1
Power module, -48V DC input
FA
1
Fan module
SA
1
Site alarm board
© ZTE Corporation. All rights reserved
DC Power Cable
The DC power cable is used for connecting the ZXSDR B8200 TL200 to an external power distributed unit.
Name
Signal Description
End A
End B
-48 V RTN
Voltage: 0 VDC
A1
Black conductor
-48 V
Voltage: -48 VDC
A2
Blue conductor
© ZTE Corporation. All rights reserved
PE Cable
The PE cable is used for connecting the ZXSDR B8200 TL200 to the grounding network, so as to provide protection and ensure personal safety. The PE cable is a 16 mm2 yellow-green cable with TNR terminals at both ends.
© ZTE Corporation. All rights reserved
S1/X2 Cable
S1/X2 optical fiber
OMC/S1/X2 Ethernet cable
© ZTE Corporation. All rights reserved
RF Cable
The RF cable is used for connecting the ZXSDR B8200 TL200 to the eRRU.
End A is used for connecting the eRRU, and end B is used for
connecting the ZXSDR B8200 TL200.
© ZTE Corporation. All rights reserved
Dry Contact Cable
The dry contact cable is used to connect the ZXSDR B8200 TL200 to an external monitoring device, and thus receive dry contact data from the external device or send dry contact data to the external device.
External view of a dry contact cable
© ZTE Corporation. All rights reserved
GPS Jumper
The SMA(M)-SMA(M) GPS antenna cable is used to connect the power splitter.
GPS antenna cable
Structure of embedded GPS lightning arrester
© ZTE Corporation. All rights reserved
SA Panel Cable
© ZTE Corporation. All rights reserved
Contents
eNodeB Overview
ZXSDR B8200 L200 Hardware Structure
ZXSDR R8882 Hardware Structure
ZXSDR eNodeB Maintenance
Position of the ZXSDR R8882 in the Radio Network
© ZTE Corporation. All rights reserved
Product Specifications Specifications
Description
R8882 S9000 (C)
Three optical ports; a maximum of 6 Gbps; GSM single mode; 900 MHz frequency band; 2 x 60 W
R8882 S1800 (C)
Three optical ports; a maximum of 6 Gbps; GSM single mode, 1800 MHz frequency band; 2 x 60 W
R8882 S9000 (B)
Two optical ports; a maximum of 3 Gbps; GSM single mode, UMTS single mode, or GSM/UMTS dual mode; 900 MHz frequency band; 2 x 60 W
R8882 S9000 (B6C)
Two optical ports; a maximum of 3 Gbps; GSM single mode, 900 MHz frequency band; 35MHz bandwidth for duplexer, 2 x 60 W
R8882 S8500 (B6B)
Two optical ports; a maximum of 3 Gbps; CDMA/GSM single mode, GSM/UMTS dual mode, or CDMA/LTE dual mode; 850 MHz frequency band; 2 x 60 W Two optical ports; a maximum of 3 Gbps; CDMA/LTE dual mode; 850 MHz frequency band; 2 x 60 W
R8882 S8000 (B4A)
Two optical ports; a maximum of 3 Gbps; LTE single mode ; DD frequency band; 2 x 40 W
R8882 S2600 (B4A)
Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 x 30 W Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 x 40 W, CEPT
R8882 S2600 (B6A)
Two optical ports; a maximum of 3 Gbps; LTE single mode ; 2.6 Gbps frequency band; 2 Carrier, 2 x 60 W, CEPT
R8882 S2100 (B)
Two optical ports; a maximum of 3 Gbps; UMTS single mode; 2T4R; 2100 MHz frequency band; 2 x 60 W Two optical ports; a maximum of 3 Gbps; LTE single mode or UMTS/LTE dual-mode;2100 MHz frequency band; LTE single mode 2 x 60 W, UMTS/LTE dual-mode 2x50 W
R8882 S1900 (B6B)
Two optical ports; a maximum of 3 Gbps; CDMA/GSM single mode, GSM/UMTS dual mode, or CDMA/LTE dual mode; 1900 MHz frequency band; 2 x 50 W Two optical ports; a maximum of 3 Gbps; CDMA/LTE dual mode; 1900 MHz frequency band; 2 x 60 W
R8882 S1800 (B6B)
Two optical ports; a maximum of 3 Gbps; GSM single mode, or GSM/LTE dual mode; 1800 MHz frequency band; 2 x 60 W
R8882 S1800 (B6C)
Two optical ports; a maximum of 3 Gbps; 2T2R, GSM single mode; 1800 MHz frequency band; 2 x 60 W
R8882 S1700 (B6A)
Two optical ports; a maximum of 3 Gbps; LTE single mode or UMTS/LTE dual mode; 1700 MHz frequency band; LTE single mode 2 x 60 W, UMTS/LTE dual-mode 2x50 W
R8882 S8100 (B6B)
Two optical ports; a maximum of 3 Gbps; LTE single mode ; 810 MHz frequency band; 2 x 60 W
R8882 S7200 (B6A)
Two optical ports; a maximum of 3 Gbps; LTE single mode; 2T2R; 720 MHz frequency band; 2 x 60 W
© ZTE Corporation. All rights reserved
ZXSDR R8882 Hardware Overview The ZXSDR R8882 and a Base Band Unit (BBU) form a complete BTS/NodeB/eNodeB, implementing radio transmission in the covered area, controlling radio channels and realizing the communication with the Base Station Controller (BSC)/Radio Network Controller (RNC)/Long Term Evolution (LTE).
R8882 2x40 W
R8882 2x60 W
© ZTE Corporation. All rights reserved
Interfaces and Indicators (ZXSDR R8882 With Two Optical Interfaces)
© ZTE Corporation. All rights reserved
Interfaces and Indicators (ZXSDR R8882 With Two Optical Interfaces) No.
Silkscreen
Interface
Connector Type
1
PWR
-48V DC power input interface
2-pin round plastic connector (male) -
2
MON
External monitoring interface
8-pin straight panel-mounted welded round socket (male)
-
3
AISG
AISG interface
8-pin socket with a square base
AISG
4
-
PE interface
16 mm2 yellow/green round terminal
-
5
OPT1
Interface for connecting a BBU and an RRU, or cascading RRUs
LC optical connector (IEC 874)
ZTE private protocol
6
OPT2
Interface for connecting a BBU and an RRU, or cascading RRUs
LC optical connector (IEC 874)
ZTE private protocol
7
ANT4 TX1/ RX1
Antenna feeder interface (Tx1/Rx1)
DIN connector
-
8
ANT3 RX3 (Optional)
Antenna feeder interface (Rx3) DIN connector
-
9
ANT2 RX2 (Optional)
Antenna feeder interface (Rx2) DIN connector
-
10
ANT1 TX0/ RX0
Antenna feeder interface (Tx0/Rx0)
DIN connector
-
11
LMT
Ethernet interface for operation and maintenance
8P8C shielded angle PCB socket with LED (left yellow, right green)
-
© ZTE Corporation. All rights reserved
Compliant Protocol
Interfaces and Indicators (ZXSDR R8882 With Two Optical Interfaces)
Two Optical Interfaces
© ZTE Corporation. All rights reserved
Three Optical Interfaces
Indicator Description Name
Meaning
Color
Flashing at 2 Hz: The system is operating properly.
Power-on status indicator
Green
ALM
Alarm indicator
Red
OPT1
Optical interface status indicator
RUN
OPT2
OPT3
Optical interface status indicator Optical interface status indicator
Operation Mode On and other blinking modes: The system is being started or is not operating properly. Off: The system is not powered on.
1
On: There is an alarm reported. Off: There is no alarm reported. Flashing: Optical interface 1 is communicating properly.
Green
On: Optical interface 1 is not communicating properly (with optical signals). Off: Optical interface 1 is not communicating properly (without optical signals).
2
Flashing: Optical interface 2 is communicating properly. Green
On: Optical interface 2 is not communicating properly (with optical signals). Off: Optical interface 2 is not communicating properly (without optical signals).
3
Flashing: Optical interface 3 is communicating properly. Green
Off: Optical interface 3 is not communicating properly (without optical signals).
VSWR 1
Tx0 VSWR status indicator
Red
VSWR 2
Tx1 VSWR status indicator
Red
© ZTE Corporation. All rights reserved
On: Optical interface 3 is not communicating properly (with optical signals).
On: TX0 antenna VSWR alarm Off: normal TX0 antenna VSWR On TX1 antenna VSWR alarm Off: normal TX1 antenna VSWR
Interfaces and Indicators (ZXSDR R8882 With Three Optical Interfaces)
© ZTE Corporation. All rights reserved
Interfaces and Indicators (ZXSDR R8882 With Three Optical Interfaces) No.
Silkscreen
Interface
Connector Type
Compliant Protocol
1
PWR
-48V DC power input interface
2-pin round plastic connector (male)
-
2
MON
External monitoring interface
8-pin straight panel-mounted welded round socket (male)
-
3
AISG
AISG interface
8-pin socket with a square base
AISG
4
-
PE interface
16 mm2 yellow/green round terminal
-
5
OPT1
Interface for connecting a BBU and an RRU, or cascading RRUs
LC optical connector (IEC 874)
ZTE private protocol
6
OPT2
Interface for connecting a BBU and an RRU, or cascading RRUs
LC optical connector (IEC 874)
ZTE private protocol
7
OPT3
Interface for cascading RRUs on the same branch
LC optical connector (IEC 874)
ZTE private protocol
8
ANT4 TX1/ RX1
Antenna interface (Tx1/Rx1)
DIN connector
-
9
ANT3 RX3 (Optional)
Antenna interface (Rx3)
DIN connector
-
10
ANT2 RX2 (Optional)
Antenna interface (Rx2)
DIN connector
-
11
ANT1 TX0/ RX0
Antenna interface (Tx0/Rx0)
DIN connector
-
12
LMT
Ethernet interface for operation and maintenance
8P8C shielded angle PCB mount socket with LED (left yellow, right green)
-
© ZTE Corporation. All rights reserved
DC Power Cable
Name
Definition
Core Color
-48 V
-48 V DC power
Blue
-48 V GND
-48 V DC ground
Black
© ZTE Corporation. All rights reserved
Antenna Feeder Cable
© ZTE Corporation. All rights reserved
Fiber
Fiber Cable for Connecting an RRU to a BBU
Fiber Cable for Cascading RRUs
© ZTE Corporation. All rights reserved
RRU Technical Specifications
Index
Specification
Dimensions (H x W x D)
480 mm x 320 mm x 150 mm
Weight
23 kg
Power Supply
–48 V DC (–57 V DC to –37 V DC)
Grounding
In practical applications, the grounding resistance must be less than 10 Ω.
Temperature
-40℃ to +55℃
Humidity
10%–100%
© ZTE Corporation. All rights reserved
Power Consumption Item
Specifications
Average power consumption in GSM single mode
S44: 310 W(900 MHz) / 320 W(1800 MHz) S66: 295 W(900 MHz) / 305 W(1800 MHz) S66: 355 W(850 MHz) / 440 W(1900 MHz)
Average power consumption in UMTS single mode (900 MHz)
S1: 140 W S2: 165 W S3: 185 W S11: 210 W S22: 265 W S33: 310 W S1 MIMO: 210 W S2 MIMO: 265 W S3 MIMO: 315 W
Average power consumption in UMTS single mode (2100 MHz)
S1: 130 W S2: 150 W S3: 180 W S11: 200 W S22: 215 W S33: 265 W S1 MIMO: 170 W S2 MIMO: 215 W S3 MIMO: 270 W
Average power consumption in CDMA single mode
310 W (850 MHz) / 320 W (1900 MHz)
Average power consumption in LTE single mode
330 W (1800 MHz)
Rated input voltage
–48 V DC (–57 V DC to –37 V DC)
© ZTE Corporation. All rights reserved
Radio Performance Item
Specification
GSM single mode
Maximum: 2 x 6 carriers
UMTS single mode
Maximum: 2 x 4 carriers
CDMA single mode
Maximum: 2 x 8 carriers
LTE single mode
1 carrier
GSM/UMTS dual mode
2 x 4 GSM carriers + 2 x 1 UMTS carriers, or 2 x 2 GSM carriers + 2 x 2 UMTS carriers
GSM/LTE dual mode CDMA/LTE dual mode UMTS/LTE dual mode
© ZTE Corporation. All rights reserved
• G/L dual-mode 900 MHz: 8 GSM TRXs + LTE 10 MHz • G/L dual-mode 1800 MHz: 8 GSM TRXs + LTE 20 MHz 2 x 4 CDMA carriers + 2 x 1 LTE carriers
• U/L dual-mode 2100 MHz: 2x 2 UMTS carriers + LTE 20 MHz • U/L dual-mode 1700 MHz: 2x 2 UMTS carriers + LTE 20 MHz
RF Specifications Item
Specification
Working frequency band
• GSM: 850 MHz/900 MHz/1800 MHz/1900 MHz • UMTS: 850 MHz/900 MHz/1900 MHz/2100 MHz • CDMA: 850 MHz/1900 MHz • LTE: 800 MHz/1800 MHz/2600 MHz/1700 MHz/720 MHz
Transmit power
• GSM (850 MHz/900 MHz/1800 MHz): 2 x 60 W(GMSK)/2 x 40 W(8PSK) • GSM (1900 MHz): 2 x 60 W(GMSK)/2 x 32 W(8PSK) • UMTS: 2 x 60 W(900 MHz/2100 MHz/850 MHz),2 x 60 W(1900 MHz) • LTE: 2 x 60 W(S1700)/2 x 60 W(S1800)/2 x 40 W(S8000)/2 x 30 W(S2600)/2 x 60 W(S7200)
Static receiver sensitivity
• GSM: –113.5 dBm (850 MHz/900 MHz/1800 MHz) • UMTS single antenna: –125.8 dBm • UMTS dual antennas: –128.5 dBm • CDMA: –115 dBm • LTE single antenna: –106 dBm • LTE dual antenna: –108.6 dBm
© ZTE Corporation. All rights reserved
Contents
eNodeB Overview
ZXSDR B8200 L200 Hardware Structure
ZXSDR R8882 Hardware Structure
ZXSDR eNodeB Maintenance
Operation And Maintenance
© ZTE Corporation. All rights reserved
Operation and Maintenance Measuremen t Task Management
Performance
QoS Task
KPI
Management
Performance Management
Performance
Performance
Data
Report
Management Performance Graphic Analysis
© ZTE Corporation. All rights reserved
Operation and Maintenance
Monitor equipment
Fault managem ent Faults oriented
© ZTE Corporation. All rights reserved
Multiple
alarming methods
Operation and Maintenance
Configuration Management • NE data configuration • Data download/upload
• Data comparison • Data output/input • Data audit • Dynamic data management • Time synchronization
© ZTE Corporation. All rights reserved
Operation and Maintenance
Security log
Log managem ent
© ZTE Corporation. All rights reserved
System
Operation
log
log
Operation and Maintenance login authentica tion
Specifies the roles
Security
operation
manage
authentica
ment
tion
Ensures the
legitimacy of the operation
© ZTE Corporation. All rights reserved
Operation and Maintenance RRU OAM • The ZXSDR R8972 configures RRU in accordance with configuration data, forwards RRU’s
management commands from the NetNumen U31, and collects RRU’s alarm and performance information. SON Functions • SON functions can help perform some network planning, configuration, optimization, and
healing processes automatically, and lower OPEX by reducing manual involvement in such tasks. © ZTE Corporation. All rights reserved