Service news
Series
The supplier Mecos solved the problem in January 2010. For the IMC15 starting with AAZUP, the problem no longer occurs.
Date: 2013-02-08 Source: TCHB550lr, 2012-09-10 Contact person: SCC CO2 laser
IMC15: Error in the regulation of the magnetic bearing Lasers
TruFlow Laser with IMC15 (magnetic bearing and motor controller): • • •
•
Problem
TruFlow 3200-6000 V0 TruFlow 8000-15000, large product group TLF 2400t – 5000t with LSM and retrofitted IMC15 TLF 6000t – 12000t with LSM and retrofitted IMC15
The following errors occur sporadically: At the start or at the self test of of the IMC15: Calibration error (not calibrated). Errors with the self test drive (DrivePerm). Magnetic bearing position or integrator error error (XFlt and/or ItFlt). Position error and field weakening weakening error (XFlt + DrFldWk). Internal under-voltage under-voltage error (U15N_UN or or U15P_UN). • • •
•
•
Cause
i1088en.docx
Defective electronic component in the sensor circuit of the magnetic bearing regulation. The problem first occurs after an operating time of about 4 years. This applies to IMC15 up to and including serial number AAZUO.
Dongle plug CCK1
Measures required
Fig. 65235
Mecos developed a dongle plug which solves this problem. Starting in November 2012, Sales is sending, bit by bit, the "dongle plug replacement part set" in sufficient quantity to all subsidiaries and representatives. As soon as the replacement part sets are available, in the course of service missions which take place anyway: 1. Shut down the laser laser and turn off the main switch. 2. Plug the dongle dongle plug CCK1 into the free socket "X1 ECA6/CAN" in the housing of the IMC. Duration: ca. 20 min. This measure can also be performed by the customer. The retrofit instructions come with the replacement part set. The dongle plug solves the problem for IMC15s which are already damaged. 1
If the dongle plug is unintentionally plugged into a new IMC15 (starting with serial number AAZUP) because it has no effect on the function. Mecos will bear the material costs. The TRUMPF subsidiary or the agency which performs the measure bears all of the costs. SIS
Spare part
2
The project "IMC dongle plug CCK21" (ID 31123) has been placed in the SIS. Document your measures in SIS or contact:
[email protected]. Dongle plug CCK1: Material no. 1793839
i1088en.docx