SAUDI ARAMCO ID/PID - REV 1 - 5/18/05 (Standards Cutoff - August 2004) SATIP No.
SAUDI ARAMCO TYPICAL INSPECTION PLA Hydrostatic Testing of Pipelines Pipelines
SATIP-A-004-03
PROJECT TITLE:
ITEM NO. 1.0 1.0
PROJECT PHASE & Ac ti vi ty Co de
APPROVED DATE
WBS/BI/JO/NO.
TASK / ACTIVITY
QUALITY PROCEDURE
QUALITY RECORD
DISCIPLINE:
MECHANICAL
25-May-05 CONTRACTOR/SUBCONTRACTOR
INSPECTION RESPONSIBILITY ASSIGNMENTS CNTRCTR
SAUDI ARAMCO
REMARKS
DOCU DOCUME MENT NT REVI REVIEW EW
1.1
Hydrostatic testing Procedure
SAIC-A-2001
RH1
RH1
1.2
Revi Review ew of Test Test Pack Packag age e Prep Prepar arat atio ion n
SAIC SAIC-A -A-2 -200 003 3
RH1
R2
1.3
Lay-Up Procedure
SAIC-A-2007
RH1
RH1
Verification of water chemistry and corrosion inhibitor
SAIC-A-2008
SATR-A-2014
RH1
R1
SAIC-L-2139 SATR-A-2007
H1
H1
In conjunction with Pipeline SATIP-L-450-03, SATIP-L-450-04.
SAIC-A-2017 SATR-A-2008
H1
W1
In conjunction with Pipeline SATIP-L-450-03, SATIP-L-450-04.
H1
W1
Forms SATR-A-2003 shall be used for 24-hr recorded hydrostatic test, Ie; underground piping or piping whose joints are covered before pressure testing.
W1
S
2.0
MATERIAL RECEIVING
2.1 3.0
A PP PPL IC ICA TI TION
3.1
Pre-Test Punchlisting-PIPELINES
3.2
Cleaning/Flushing (Scraping) prior to hydrotest
SAIC-L-2139 SAIC-A-2017
SATR-A-2002 SATR-A-2003 SATR-A-2004 SATR-A-2005 SATR-A-2006 SATR-A-2001 (for test Manifold)
3.3
Test Preparation & Verification of Testing equipment (including safety requirements)
3.4
Filling & Pressurization a. Strength Test Pressure Pressure b. Tightness Test Pressure
SAIC-A-2013
3.5
Visual Inspection at Test Pressure
SAIC-A-2015
SATR-A-2001
H1
H1
3.6
Pneumatic Testing of Reinforcing pads/sleeves covering pressure containing Welds and Weld+ End Couplings
SAIC-A-2016
SAIC-A-2016 SATR-A-2001
W1
W1
4.0
* See Note 1 (General Notes)
POST- TEST
SAIC-A-2009
Form SATR-A-2001 is a modified version or merging of Forms SA-2642ENG & SA-2642-1
SAUDI ARAMCO ID/PID - REV 1 - 5/18/05 (Standards Cutoff - August 2004) SATIP No.
SAUDI ARAMCO TYPICAL INSPECTION PLA Hydrostatic Testing of Pipelines
SATIP-A-004-03
PROJECT TITLE:
ITEM NO.
APPROVED DATE
WBS/BI/JO/NO.
PROJECT PHASE & Ac ti vi ty Co de
TASK / ACTIVITY
QUALITY PROCEDURE
4.1
De-Pressurization & Water Disposal
SAIC-A-2017
4.2
Lay-up
SATR-A-2009
QUALITY RECORD
SATR-A-2009
DISCIPLINE:
25-May-05
MECHANICAL
CONTRACTOR/SUBCONTRACTOR
INSPECTION RESPONSIBILITY ASSIGNMENTS CNTRCTR
SAUDI ARAMCO
W1
S
H1
W1
REMARKS
SAUDI ARAMCO ID/PID - REV 1 - 5/18/05 (Standards Cutoff - August 2004) SATIP No.
SAUDI ARAMCO TYPICAL INSPECTION PLA Hydrostatic Testing of Pipelines
SATIP-A-004-03
PROJECT TITLE:
ITEM NO.
APPROVED DATE
WBS/BI/JO/NO.
PROJECT PHASE & Ac ti vi ty Co de
QUALITY PROCEDURE
TASK / ACTIVITY
QUALITY RECORD
DISCIPLINE:
25-May-05
MECHANICAL
CONTRACTOR/SUBCONTRACTOR
INSPECTION RESPONSIBILITY ASSIGNMENTS CNTRCTR
REMARKS
SAUDI ARAMCO
GENERAL NOTES
1
The first three incidents of each Inspection or testing activity listed require 100 % participation by Saudi Aramco Site Inspection Personnel. After this period, Saudi Aramco Inspection may adjust the levels of Saudi Aramco participation based upon the Contractor’s performance.
2
Surveillance: QA/QC organization to monitor work in progress without notice from Construction Organization.
3
Witness: QA/QC organization shall be notified of the timing of Inspection or test in advance. However, the inspection or test shall be performed as scheduled if the QA/QC organization representative is not present.
4
Hold: attendance.
5
If the Main Contractor delegates the assigned responsibility to the Subcontractor, then the Main Contractor will have the same degree of responsibility as assigned to Saudi Aramco.
QA/QC organization shall be notified of the timing of inspection or test in advance. Inspection or test shall not be carried out without the QA/QC organization representative in