2016 HCS-Pre-salesTransmission Network Huawei DWDM Product Introduction
1
Content 1
Huawei WDM Overview
2
WDM product introduction
3
Success Story
Huawei WDM at a Glance 20+ Years cooperation with 100+ carriers
170+ Countries
500+
100G Networks
500,000+
13
sets shipment of WDM/OTN
WDM Innovation centers
3,000+ WDM R&D employees
3
Stable Leading with Continuous Effective Growth Source:
Market Share(%)
30%
Global WDM 3Q15~2Q16 11.5 Billion $
24%
Huawei 18%
Ciena
12%
6%
Fujitsu 5.0%
Other 17.9%
Coriant 4.5% Infinera 7.4%
Huawei 26.7%
Ciena ZTE 14.7% 10.9% Nokia 12.8%
2010 2011 2012 2013 2014 2015 2016*
Huawei ran ks
No.1 in WD M/OTN domain over 9 years 4
Global R&D Centers of WDM
5
Awards and Honors-Driving the Industry Forward
Photonic Integration Device
InfoVision award OSN6800/3800
InfoVision award Huawei 40G
R&D 100 award SAN OTN solution
ODC 2010 Best opticvendor
Africa Com Best Cost Efficiency
Coherent 100G
ODC 2011 Best opticvendor
IIR award Next Generation Optical Awards
ODC 2013 Best opticvendor
Solution's for Africa
China National Science and technology progress award
Content 1
Huawei WDM Overview
2
WDM product introduction
3
Success Story
What is WDM ? - Wavelength Division Multiplexing OTU1
…
OTU2
…
OTU3
White Light Spectrum White light can be decomposed into different
(Cband)
λn
SDH
Optical Cable
DSLAM
colors of monochromatic light. The wavelength range of WDM:1260 ~ 1611 nm
λ1 λ2
WDM DSLAM
Core
80 lambdas in one pair of fiber, save fiber resource greatly
Huawei WDM/OTN Product Family Overview OSN902
OSN1800I/II/V
OSN8800T 16/T 32/T64
OSN 9800 U16/U32/U64
2U, 6 Slots,AC,200G Single slot, 1.2T one chassis
80 channel
Fits 19/23’rack,
Cooling: front to back
I
Metro DCI
IDC
IDC
Metro DCI
II
V
T16
T32
T64
U16
U32
U64
Compact MS-OTN
1.6T/3.2T/6.4T XC
5.6T/12.8T/25.6T XC
Service Slot 3/7/15
Service Slot 16/32/64
Service Slot 14/32/64
Line Rate 10G/100G
Line 10G/40G/100G/400G
Line 100G/400G/1T/2T
Metro Access
B ackbone
Super Backbone 9
Huawei OSN902:Electrical characteristics Metro DC IDC
IDC
10
Huawei OSN902:Mechanical characteristics
•
All Replaceable module(such as Fan, power, SCC, Board) support Hot-Swap.
•
Free Screw designed, spare parts replace within15s.
•
Services Board plug and play , it can pay as grow.
11
Two Cards for all Scenario M201: 1*100G/200G Programmable Wavelength Conversion Board
Line side: 2*QSFP28 Pluggable 100G or 200G Support 100G
5*QSFP+ Pluggable Support 10G or 40G
Up to 1.2T
M401: 400G One Lambda Conversion Board
Line side:400G
4*QSFP28 Pluggable Support 100G
Up to 2.4T 12
Free Design, Fast Delivery 200/400/800G…
Electric Optic
Optic
Electric
Point to Point Scenario Client
Configuration
N*10GE
N1*Racks+N2*M201+N3*QSFP
N*40GE
N1*Racks+N2*M201+N3*QSFP
N*100GE
N1*Racks+N2*M201+N3*QSFP28
N1*10GE+N2*40GE+N3*100GE
N1*Racks + N2*M201+N3*QSFP+N4QSFP28
Typical Optic 1~11dB(Equivalent 40KM)
Configuration 1*1800II+1*OBU+2*EX40
1~11dB(Equivalent 40KM)
7
FA 5 N 3 1
11~30dB(Equivalent 40~100KM)
EX40
EX40
11~30dB(Equivalent 40~100KM)
7
8
S CC
FA 5
6
O BU
N
4 2
3 1
8
SC C
7
6
O BU
FA 5 N 3
4 2
APIU
APIU
1
EX40
EX40
APIU
APIU
8
S CC
6
O BU
4 2
APIU
2*1800II+2*OBU+2*EX40
13
APIU
Easy Quotation
2. Fill the quantity of Client Interface
1. Select Optical Configuration
Generating Configurations automatically
14
OSN1800 Series: Mini-Size with High Capacity 1800 II
1800 I
1800 V 5U
2U
1U
H
igh Capacity
80-λ ×100G system!1800I/II/V with 3/7/15 service slots
Mini Size, Huge Capacity, Multi-service Platform FMC service transport Mobile Backhaul
M
ini OTN Pole-mounted
FTTxOu tdoor-cabinet
Wall-mounted
19/23’Rack
15
OSN1800V: Minimum Universal Switch Platform SDH
5U
OTN
PKT ANY
Mini-size + High-capacity + Universal Platform
Large capacity
80-ch DWDM, line transport capacity up to 80*100G=8Tbps
CX-Capacity up to 700G ODUk/PKT and 280G/20G SDH HO/LO
Single fiber dual direction
Universal switch
Environment friendly
Flexible Infrastructure
Integrates Packet, VC and OTN switching into a centralized, nonblocking, fully redundant switch fabric.
Rich interfaces supported E1/E3/T3/FE/GE/STM-x/ 10GE/100GE/CPRI/FC/SAN... to meet all application scenarios
5U size fits 19/23’rack ,flexibly install with other type equipment
640w (OTN)
1+1 AC/DC power supply
16
OSN 1800 100G Solution 2M~100G any rate
•One
device support 2M~10G any rate& 10G any & 40G or 100GE service
FE/GE/10GE/SDI FC100/200/400/800
Broadcast TV
STM-N/FE/GE/10GE
Data Center
Home
Office
VOD Switch
Storage Server Server
OSN 1800 card introduce
F2LTX:100G multiservice encryption card
LDX :Dual 10G service card
Service support: 10GE/FC800/FC1200/FC 1600/FC 3200 /Infiniband 5G
2 client port
Support AES256 encryption
Support 10GE/FC 800/FC 1200 ,Infiniband 5G
100G coherent line side。
10G Line side
ELOM:Multi-service 10G muxponder
CE6 :10G multiservice encryptio n card
8 client port
6 client port
Support GE/10GE/FC 100/FC200/FC400/FC 800/FC 1200
Support GE/10GE/FC100/FC200/FC400/FC800/FC1200
Support IBM GDPS STP/ISC
Support AES256 encryption
10G line side
10G line side
Service Security - Service Encryption (AES256) Security negotiation and dynamic key exchange
Encryption management
Encryption management
AES256
AES256 Customer
Customer
on Diffie-Hellman algorithm, supportdynamic key exchange automatically E2E independent security management plane Encryption message mapped into OPUK, will not change the rate of line side . Based
Provide
Fully Certification
FC Application • 2006 Huawei finished certification with EMC 、Brocade、HDS、McData. • 2008 Huawei finished certification with IBM GDPS, support Mainframe interface: IBM ETR/CLO 、
STP/ISC, and win R&D 100 Award of 2009. • 2012 Huawei OTN support IBM STP/PSIFB interface and certificated. • 2016 Huawei support FC 32G interface, and is the first WDM Vendor support this interface.
Backbone OSN 8800 Series 100G OTN Platform
OSN 8800 UPS
OSN 8800 T16
OSN 8800 T32
•C-D-C-G ROADM
•1.6T OTN XC, 800G PKT,
•3.2T OTN XC, 1.6T PKT,
•100G/400G/1T/2T
640G VC4,20G VC12;
1.28T VC4, 80G VC12;
Big Capacity
OSN 8800 T64 •6.4T OTN XC, 1.28T VC4,
Long Distance
MS-OTN
1.6T/3.2T/6.4T OTN capacity
4000km without REG by 80*100G
OTN/SDH/PKT universal platform
80*40G/100G
Single hop over 300+Km for 100G
2/4/9-ROADM, O/E ASON, T-SDN
ODUflex
Low carbon , 1588V2
OTN/SDH/Packet Convergence, ASON/T-SDN Based Architecture, 100G OTN Platform
OSN 8800 support flex grid & Extended C Band 100Gbit/s, each channel is 50GHz space
………………
50GHz
50GHz
50GHz
50GHz
50GHz
50GHz
50GHz
Fixed grid: 50Ghz 400Gbit/s
λ80
λ1 Lambdas @ C band
1Tbit/s Super Channel
………………
87.5GHz
200GHz
Flex grid: 37.5Ghz
λ1
λ128
Lambdas @ Extended C band
Extended C band Mux / Demux: TM20,TD20,M48,D48,MD20,TD20,ITL04,FIU02,OPM
Extended C band OA: OAU202,OBU202,RPC03,ROP01,RPC01,HBA
DWDM Solution in Submarine System
Unify management Lambda
OTU
Terrestrial system
The
Lambda 1
Lambda 1
RPT
RPT
Submarine system
Lambda
OTU
Terrestrial system
Huawei submarine and terrestrial DWDM share the same platform and board , do not need OTU back to back connection. Less boards and spare parts , saving cost 30% more.
Industry 1st ULH Submarine System Up to 12,000KM transmission distance in Huawei ULH Repeater System South Africa to UK Cross the Atlantic submarine
•
Maximum capacity: 100G
•
Up to 12000km transmis si on distance
128chs
Single long reach up to 550KM in Huawei Repeater-less System BU
Lombok
• 10G system: up to 550km
Ambalawi
HUAWEI MARINE
Flores BU
Sumbawa
Sumba
• 100G system: up to 450km
Timor
Indonesia Telkom MKCS S ubmarine Pr oject • Service Launch: April.2011 • Long reach segmentgreater than 400kmwith ROPA/Enhanced Ramantechnology
Super Backbone OSN 9800 Series 9800 U32
9800 U64
9800 U16 9800 UPS
•Universal optical subrack
•Single-side subrack
•Single-side subrack
•Dual-side subrack
•C-D-C ROADM
•14 slots
•32 slots
•64 slots
•Flex-grid ROADM
•400G per slot capacity
•400G per slot capacity
•400G per slot capacity
•100G/400G/1T/2T
•5.6Tb/s Switch
•12.8Tb/s Switch
•25.6Tb/s Switch
Optical Packet Convergence, T-SDN Based Architecture, 400G/1T/2T Oriented Platform
Highly integrated OTN board
Line side
N402 2×100G
N501 200G
N601 400G
Trib. side
T404 4×100GE
T302 2×40G
T220 20×10G
T130 30× Any
Industry 1st Universal MS-OTN Line Card TraditionalMode OTN
OTN Tributary Card
OTN Line Card
TDM
TDM Tributary Card
TDM Line Card
Univers alLineCardMode λ1 OTN
OTN Tributary Card
TDM
TDM Tributary Card
λ2
0%
ODUk
100% VC
PKT
Packet OTN TDM ODU
PKT
PKT Tributary Card
PKT Line Card
λ3
PKT
PKT Tributary Card
VC
PKT
λ1
Universal line card supports 100% OTN or 100% VC or 100% PKT bandwidth utilization
Fully shared 100G/B100G bandwidth without any fragments.
Huawei Super 100G, Performance Reach 10G Level
6000km Long Haul Transmission 50 span x 120km(25dB)+SRAU
RZ Modulation + Bit Interleaved tech., Reduce Nonlinear Penalty
TX Pre-Shaping , Reduce FilteringTech. Penalty
Advanced B2B BICC* FEC Requirement Algorithm, Decrease OSNR
Coherent Receiver, Eliminate CD&PMD Penalty
0.3dB improve from LDPC to BICC
*BICC: Block Interleave Convolution Code
Super Raman, enhance 200G/400G Performance Hybrid OA MONS
400G 16QAM(EDFA): 1000Km
SYS MONO
7
8
LINE
OUT
400G 16QAM(SRAU): 1700Km
SafeasEDFA
Auto switch off pumping laser when failure
EasyDebug
Automatic gain control
Real-time monitor
Debugging by remote
HighIntegration
Pluggable Raman board
Only 2 slots
DWDM is a Must for Ultra Long Haul Span Generation
Distribution
Transmission Network
365 KM Power Plant
Substations
Substations
EDFA
Hom e
Factory CBD
EDFA ROP
ROP
For super high voltage transmission there are some span over 300KM.
RGU
Enhanced Raman
Ba n d w i d t h
Distributio n
Consumption
C o n f i g u r a t io n
Enhanced Raman
Wa v e l e n g t hNu m b e r
Use ROP
1
Span db) 91dB/330km
10G UseforwardandbackwardRaman
1
ROP Use
101dB/365km 1
83b/310km
100G UseforwardandbackwardRaman
1
93db/345km
The Huawei DWDM can provide 101dB span loss transport capability which is much stronger than other type of equipment.
High Integration: Coherent CFP Coherent CFP
G404
400G
4*100G Line FIC
4*OTU4
Service Process
100G
Values to Customers 1、Flexible and reduce initial cost 2、High integration, improving ability of chassis access 100%
400G Programmable Card Multi-Modulation, Set by Software 2*100G
37.5 GHz
37.5 GHz
2ch PDM-QPSK Baud rate: 32G
400G N402P
2SC-PDM-QPSK Baud rate: 64G 2SC-PDM-8QAM
Distance 5000km@RAU
150GHz
2400km@RAU
100GHz 1500km@RAU
Baud rate: 45G 75GHz
Values to Customers:
2SC-PDM-16QAM Baud rate: 32G
Different Modulation for Different Scenarios, improving capacity of fibers or distance.
Single Hardware with software defined for different Code Type.
1400km@RAU
Upgrade to 400G/2T Smoothly 1 00 G 10 0G 400G
9800 OTN subrack
100G Line Card
Phase 1
100G OTN
200G Line Card
400G Line Card
Phase 2 100G+400G OTN
OSN 9800 Supports 400G/2T Smoothly
400G
2T Line Card
1T
2T
Flex-Grid ROADM/MUX/DEMUX
Phase 3 100G+400G+2T OTN
ASON Provides High Reliability & Easy OAM Electrical Diamond
Optical Diamond
D2 D1
1
ROADM
R OA D M
R OA D M
D3
D1
1
D2
D3
R OA D M
R OA D M
Line Card
Line Card
Tributary Card
Tributary Card
1. Based on ROADM optical cross-connection;
1. based electrical cross-connection, including ODUk\VC;
2. Wavelength-level effective protec tion;
2. Sub-wavelength-specific protection;
3. Protection path need reserved the wavelength;
3. No optical restrictions;
4. Reroute time > 3 s.
4. Reroute time < 50ms.
Industry 1st Integrated Optical Doctor v2.0 OSNR Detection
Online Monitor
Fault Diagnosis
NMS function replacing spectrum analyzer
Carefree OAM for optical layer performance
• •
Online auto scan and
•
The industry first 100G
monitor performance
E2E OSNR detection
Save instruments & manual
(including OLA sites) •
work
Auto Optimization
+/-0.5dB precision
•
Pre-warning for poor section and OCh
•
Friendly GUI to display fault section
Enhance ASON Function
Optical Doctor v2.0 Power
Before
OPM8
OPM8
OLA
OLA
OLA
OADM
After Poor Performance
•
OADM
Power
Performance Optimized
Optimize the worse OCh automatically after user
•
confirmed
•
Choose the best rerouting path according to OD report Avoid fail switch by pre-warning of poor performance
Industry 1st Integrated Fiber Doctor Optical Doctor
OSC Card (w/i eOTDR)
Fiber Length Test
Attenuation Test
Fault location
(break, bend, splice, etc)
BlackBox
WhiteBox
Invisible, Unmanageable
Visible, Manageable
Online Monitor
Wide Range
Fast Trouble shooting
Multi Scenarios
No interference for online service
Measurement range up t o 160km
High measuring accuracy
Legacy + New-built Network
Content 1
Huawei WDM Overview
2
WDM product introduction
3
Success Story
AMS-IX: Open cloud era of WDM-based DCI AMS-IX ( Amsterdam Internet Exchange)
0.5W/Gbit 2U,CFP2-ACO Low power
•
Established 1997 in Amsterdam
•
5Tbit in peak flow, Over 800 participating SPs
•
Helped make Amsterdam one of the main hubs in global
Internet Traffic
Huawei Solution •
>20T One pair fibers
<1 min Open API Plug and play
•
OSN902 100G WDM Data Center Solution Support Single Span 40KM Without Amplifiers
•
Support Single Fiber Bi-direction
•
Simply O&M, pay as grow
Austria OBB Railway Backbone Austrian Federal Railways (OBB) •
With one hundred years of history
•
Annual sales is more than 6 billion Euros
•
The train punctuality rate is over 96.7%
•
The Europe's sixth-largest railway company
Huawei Solution •
OSN 8800 100G MS-OTN Solution
•
Ultra-High bandwidth: advanced 100G/400G coherent technology. Ultra-High utilization efficiency: advanced OTN architecture and
•
ROADM technology enables most network flexibility. •
Intelligent network: OAM tools(OD, FD, etc.)simplify network
design, deployment, management and maintenance .
Gas&Com in Switzerland
As
an independent provider of telecom infrastructure business GAS&COM LTD. provides its c lients with fibre optics Connections, broadband-, ip-servicesand infrastructure. The
ducts as well as the cables and infrastructure of GAS&COM LTD. are placed along the Swiss Natural Gas pipelines. Pipelines in Switzerland and in the Principality of Liechtenstein are subject to very strict monitoring security guidelines. Being placed mostly next to the pipelines, the dedicated track of GAS&COM LTD. takes advantage of the high security standard. The risk of any damage to the cable track is therefore very low. As
a result of our longstanding relations to the network providers in the cities and surroundings, we are able to offer exclusive connections from home to home and from city to city in Switzerland as well as metropolis abroad
Solution Success: Gas&Com in Switzerland Mix solution achieve Cost efficient
10G network a lso can DCM free
MS-OTN can instead s witch
Universal Switch SDH
OTN
OSN 1800V
PKT
OSN 9800 U16
VC
ODU
PKT
For enterprise customer they do not as skillful as carrier customer,we need to analysis Traffic Volume in network.
Low Traffic Volume site can use c heap equipment ,Single equipment solution may
not cost efficient.
1800(NQ2)line side and 9800(N220) line side can connect directly.
For dedicated line,sort of enterprise such as financial factor in sensitive to latency. Decrease latency is more competitive for a
For Carrier customer,their network is divide into L1+L2+l3 clearly. In bandwidth rental scenario there is no much
dedicated line provider.
requirement on L2 switch,MS-OTN can
For 1800 10G branch,we can save DCM since
substitute switch equipment.
1800 10G branch is short.
Ufinet in Spain
Ufinet is a subsidiary underneath Gas Natural Fenosa(GNF),GNF is a gas and power grid company. • Ufinet is a neutral wholesale operator in the
telecommunications market. • provide data connectivity to clients through fiber optic with extensive network coverage in major cities in 11 countries. • has 43,500 km fiber-optic network in Spain and Latin America, including 12,500 km in Spain, 31,000 km in Latin American. • over 18 years of experience
Solution Success: Ufinet in Spain 484.5G
484.5G
Planner 2116 save 20% OTU Board
484.5G 484.5G
484.5G
3.5G
484.5G
100G line card 186
484.5G
LOTE4 206.5G
150
502G 502G
484.5G
484.5G
save 20%
502G
LOTE5 502G 359.5G
359.5G
LOTE3
861.5G
654G
502G
before
511.5G LOTE2
network.
152G 100G
359.5G
102G 94G 359.5G
359.5G
after
Ufinet want to build pure 100G line speed
For some span,bandwidth is like 502G in Lotes 5. if Allocate one 100G wavelength for
152G
2G is too waste.
359.5G 40G
10G
By using wavelength share technique (2116) can save line card.
Expanding Victory, Won Colombia Ufinet Regional Cooperation Bring More Opportunity
After we win contract from Ufinet Spain, we spread this new to Columbia local team. Columbia local team try to contact Ufinet Columbia office,and find out they also want to upgrade Columbia network.
mBank Data Center Interconnect in Poland
• mBank the first fully Internet-based bank in Poland and are one
of the strongest and fastest growing financial brands in Poland, listed on the WarsawStock Exchange for 23 years now.mBank among the largest banks in Poland(4rd position) • After the brand unification in November 2013, when the mBank
name replaced not only the name of the company, but also the BRE and MultiBank brands. • mBank have 4 DC need interconnected,two of them are temporary DC, future will merge to other two main DC.
Solution Success in mBank Single 100G
Muxponder support all mBank required interface (10GE/FC16G/40GE)
Mainstream 100G Single
coherent technology ,compare to 4x28G MLSE,easy to deploy,low latency,reliability.
card type reduce OPEX.
λ1
FC 16G
LTX
10GE
LTX
λ2
λn
LTX
OSN 1800
OSN 1800
100G channel
OSN1800 F2LTX card Single card support all service interface
…
40GE
100G coherent
Solution Success: Gasline in German Service mode is also attractive
GasLINE GmbH & Co. KG was established in 1996 by 15 German gas transmission and regional distribution companies. It has a Germany-wide integrated fiber-optic cable network, offering dark fiber capacity to national and international telecommunication companies. The cables which, for safety reasons, are usually installed in the rights-of-way of gas , connect the telecommunication pipelines hubs of all major cities. The GasLINE network presently comprises more than 10,000 km of fiber-optic cable. It is gradually expanded in line with customer needs and specifications. In more than 100 cities, the GasLINE cable network connects to telehouses and so-called "Points of Presence" (POPs).
Gasline use to rent fiber, this customer intend to rent bandwidth from this year.
Gasline need equipment provider help them establish maintenance capability.
Huawei can provide Agent Maintenance mode to reduce human cost for customer.
Adva can not provide Agent Maintenance
Solution Success: Fibercomm in Malaysia
TNB(Tenaga Nasional Berhad) is a traditional power grid company. TNB deploy fiber along with power grid from beginning. As a result TNB own a fiber network across country. TNB and TM (Telekom Malaysia) establish their individual joint ventures Fibrecomm. The Fibrecomm can leverage TNB fiber network to develop private line,DC interconnect service. The Fibercomm use Huawei 1600G equipment in network,but 1600G is going to end of service.
Solution Success: Fibercomm in Malaysia Utilize Existing Resource
1600G Optical layer
9800 electrical layer
The existing network is Huawei 1600G and Ciena.
For future bandwidth rental business develop, We suggest Fibercomm to deploy 100G network with utilizing existing 1600G optical layer,
In this way we operate this project as a expansion project to exclude Ciena.
Power grid RNT in Angola need WDM
The RNT is a national power grid company in Angola. RNT construct fiber network not only for bandwidth rental but also for bear product service of his own.
Trend
Power grid also have high bandwidth requirement. In Angola,skillful engineer are working around capital area. In far and remote site if there is a equipment breakdown taken place,the senior engineer need use high definition camera to observe equipment remotely. Then guide local worker to perform maintenance through high definition camera .
Thank you